Search NASA⌕ Search

SEARCH · Search NASA

Results for “nuclear sensor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

Behavior of the Fused Quartz Suspended Core Acoustic Waveguide Sensor in Gamma Radiation

Previously, a fused-quartz acoustic waveguide named the suspended core waveguide with tight-field confinement in a small diameter was developed and its sensing potential in harsh environment was demonstrated with the fabricated periodic acoustic fiber Bragg grating. In this paper, the acoustic sensor was exposed to around 70 Gy/h gamma radiation at room temperature for 3550 h at Oak Ridge National Laboratory. For comparisons, a thermocouple and two optical fiber Bragg gratings were tested under the same conditions. The central frequency reading of the acoustic sensor was found to encounter a relatively fast decrease of 0.5 kHz in the first 800 hours. The reading then became stable, centering at 478.5 kHz with a fluctuation of ±0.2 kHz, and responded to small environmental temperature variations less than 1.2 °C. The major effect to the fluctuation was concluded to be radiation-induced material compaction and expansion. For optical fiber Bragg gratings, the same one-directional fast change of readings in the first 500 hours were observed as well. Although the optical gratings were able to track temperature changes, they also showed continuous drifts. The survivability and consistency of the acoustic sensor under long-term gamma radiation could lead to new sensing methods in nuclear applications.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Large tetragonality and room temperature ferroelectricity in compressively strained CaTiO 3 thin films

We report that ferroelectricity and piezoelectricity are desirable for a variety of high-temperature applications such as actuators and sensors in heat engines, high-temperature manufacturing, and space technologies; however, the number of such material candidates is currently limited. Here, we demonstrate that CaTiO 3 , the first discovered perovskite mineral that is abundantly found in the Earth, as a non-polar bulk form, becomes a high-temperature ferroelectric oxide under compression. A strain-phase-temperature diagram of CaTiO 3 is created by growing a series of thin films with a range of compressive and tensile strains. Using temperature dependent optical second harmonic generation analysis, we show that tensile strained films exhibit predominantly in-plane polarization with orthorhombic-like point group symmetry with a phase transition below room temperature. On the other hand, compressively strained CaTiO 3 films exhibit a neartetragonal unit cell with a c/a ratio of 1.03, larger than that of classic ferroelectric, e.g. BaTiO 3 (c/a~1.01). These films exhibit a robust and switchable out-of-plane polarization at room temperature, with a ferroelectric transition temperature up to ~800 K. Density functional theory calculations reveal that compressive strain gives rise to a large out-of-plane displacement of Ti-cations inside the TiO 6 octahedral cages responsible for the strain induced polarization of ~ 9μC/cm 2 . Given that nearly half of the perovskites exhibit the bulk symmetry of CaTiO 3 , compressive strain tuning of this family may prove to be a fertile ground for the discovery of strain-induced piezoelectrics and ferroelectrics at high-temperatures. High-temperature piezoelectric sensors are important for many industries such as automotive, aircraft, and aerospace, as well as nuclear and geothermal energy, where dynamic structural monitoring of high-speed rotors in engines, turbines, and power generators is critical for safety and reliability.[1, 2] Modern sensors are however limited, where the main challenges are maximizing operating temperatures while maintaining good sensing capability and low electrical leakage.[3] High-temperature piezoelectric materials are typically derived from BaTiO 3 or PbTiO 3 based ceramics and single crystals, as these materials are also ferroelectric, meaning that they have a built-in spontaneous polarization (Ps). In bulk, these standard ferroelectric perovskite materials yield maximum operating temperatures ranging from 250-450 °C.[4], where above these temperatures the spontaneous polarization (P) and piezoelectric properties disappear due to the onset of a ferroelectric-to-paraelectric phase transition (TC). As next-generation engines, turbines, and reactors require hotter operating temperatures above 500 °C, materials with enhanced ferroelectric properties and increased ferroelectric transition temperatures will be needed in such extreme conditions. A promising way of boosting ferroelectric transition temperatures and polarization is through epitaxial strain engineering,[5] where tremendous in-plane distortions can be applied to thin film crystal materials, well beyond the point at which their bulk ceramic and single crystal counterparts would crack. Strain engineering has proven to drastically enhance ferroelectric polarizations and transition temperatures in classic ferroelectric materials such as BaTiO 3 [6] and PbTiO 3 [7], and strain can even turn on ferroelectricity in otherwise non-polar materials such as SrTiO 3 and CaTiO 3 ,[8] although reported strain-induced ferroelectric transition temperatures are only at room temperature or below.[9-12] In this work, we will focus on strain-induced ferroelectricity in CaTiO 3 , the first discovered perovskite mineral and long known to be a simple nonpolar insulating crystal.

36 MATERIALS SCIENCE↗

Detection and Defeat of Autonomous Sensors

Presentation to be made a the June 15 works in progress (WIPs) WebEx. The presentation will be later uploaded to the Science & Technology website.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Direct Electrical Detection of Iodine Gas by a Novel Metal–Organic-Framework-Based Sensor

High-fidelity detection of iodine species is of utmost importance to the safety of the population in cases of nuclear accidents or advanced nuclear fuel reprocessing. In this paper, we describe the success at using impedance spectroscopy to directly detect the real-time adsorption of I 2 by a metal–organic framework zeolitic imidazolate framework (ZIF)-8-based sensor. Methanolic suspensions of ZIF-8 were dropcast onto platinum interdigitated electrodes, dried, and exposed to gaseous I 2 at 25, 40, or 70 °C. Using an unoptimized sensor geometry, I 2 was readily detected at 25 °C in air within 720 s of exposure. The specific response is attributed to the chemical selectivity of the ZIF-8 toward I 2 . Furthermore, equivalent circuit modeling of the impedance data indicates a >10 5 × decrease in ZIF-8 resistance when 116 wt % I 2 is adsorbed by ZIF-8 at 70 °C in air. This irreversible decrease in resistance is accompanied by an irreversible loss in the long-range crystallinity, as evidenced by X-ray diffraction and infrared spectroscopy. Air, argon, methanol, and water were found to produce minimal changes in ZIF-8 impedance. Finally, this report demonstrates how selective I 2 adsorption by ZIF-8 can be leveraged to create a highly selective sensor using >10 5 × changes in impedance response to enable the direct electrical detection of environmentally relevant gaseous toxins.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Portable, solid state, fiber optic coupled Doppler interferometer system for detonation and shock diagnostics

VISAR (Velocity Interferometer System for Any Reflector) is a specialized Doppler interferometer system that is gaining world-wide acceptance as the standard for shock phenomena analysis. The VISAR's large power and cooling requirements, and the sensitive and complex nature of the interferometer cavity have restricted the traditional system to the laboratory. This paper describes the new portable VISAR, its peripheral sensors, and the role it played in optically measuring ground shock of and underground nuclear detonation. The Solid State VISAR uses a prototype diode pumped Nd:YAG laser and solid state detectors that provide a suitcase-size system with low power requirements. A special window and sensors were developed for fiber optic coupling (1 kilometer long) to the VISAR. The system has proven itself as a reliable, easy to use instrument that is capable of field test use and rapid data reduction using only a notebook personal computer (PC).

Fleming, K. J.↗

Characterization of the Pulsed Radiation Environment in FREC-II at the ACRR

Ongoing tests at the Annular Core Research Reactor (ACRR) at Sandia National Laboratories aim to measure temperature and strain in materials exposed to a transient neutron-photon environment. Radiation transport and finite element analysis codes are used to predict the thermal-structural response of test articles exposed in the reactor. Strain and temperature sensors fielded on test articles provide validation data for finite element models, while active and passive radiation dosimetry provides data for MCNP models. The ACRR is able to provide pulse energies of 40 - 300 MJ per pulse with pulse times of 7 - 100 milliseconds. The pulse power is higher than many of the other research reactors due to its unique high heat capacity UO{sub 2}-BeO fuel in the central reactor. Additionally, the Fuel Ringed External Cavity (FREC-II) contains U-ZrH fuel. Future tests at the ACRR plan to field test assemblies in the Fuel Ringed External Cavity (FREC-II) and expose the test articles to the transient anisotropic radiation field experienced in the cavity. The FREC-II is coupled with the ACRR core and is used to test larger specimens, and the radiation environment can be shaped/modified to the needs of the experiment. The FREC-II was designed to provide an irradiation cavity with a strong flux gradient favoring the central cavity side. Neutron fluence also varies by height in the cavity, with a peak level slightly below the fuel rod vertical centerline. Tests were conducted in 2014 to measure the thermal-structural response of test articles exposed in the central cavity. Those tests in the central cavity fielded Nickel activation foils to record the neutron fluence at various locations around the test assembly. Foil data was later used to highlight uncertainties between thermo-structural response models and the measured temperature and strain. Studies performed in 2015 exposed large arrays of activation foils and thermo-luminescent dosimeters (TLD) in the FREC-II cavity in order to map out the neutron and photon spectrum at many locations. This type of passive measurement was shown to be too simple for performing thermo-structural simulations of a test article in response to multiple pulsed-reactor exposures. The Depleted Uranium Strain and Temperature - Enhanced Response (DUSTER-II) experiments will expose test assemblies to reactor pulses in the FREC-II cavity. To prepare for these experiments, the MCNP model will be compared with June 2016 experimental results from the pulses with the FREC-II coupled with the ACRR. These comparisons will provide an accurate model to be implemented in further studies. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Fibre optic extensometer for high radiation and high temperature nuclear applications

In the framework of the Joint Instrumentation Laboratory (LCI), gathering resources from SCK-CEN (Belgium) and CEA (France), we are developing an optical sensor in order to accurately measure radiation-induced elongation of material placed in the core of a Material Testing Reactor (MTR). This extensometer displays common advantages of Fibre Optic (FO) sensors: high resolution, easy remote sensing and multiplexing, and also compact size which is of particular interest for in pile experiments with little room available. In addition, light weight reduces gamma heating hence limiting the thermal effect. In accordance with the specifications, the sensor has preferably two fixing points defining a gauge length of 10 to 15 mm (as a minimum). The diameter is less than 2 mm. Intense gamma and neutron irradiation as well as high temperatures are the most difficult environment conditions to withstand. Reactor radiation produces huge losses in common optical fibre. The losses can be limited by selecting the fibres (mainly with high purity silica core), the wavelength range (800-1200 nm), and a measurement based on interferometry (largely insensitive to losses in the fibre thanks to the wavelength encoding of the useful signal). Heavy neutron - mainly - and gamma flux such as in MTR, also produce compaction of silica, resulting in a significant drift and preventing the use of commercial FO sensors in such environment. Knowing this issue we revised the basic scheme of Extrinsic Fabry Perot Interferometer (EFPI) in order to limit the effects of compaction. A first sensor prototype fixed on a stainless steel support was tested in the Smirnof test facility in the BR2 MTR in Mol (Belgium). The support was subject to a constant mechanical and thermal stress, and his dimensions were not supposed to vary. This test showed a very low drift of the revisited EPFI design under high irradiation field in comparison with a commercial EFPI. This result has to be confirmed with second generation sensors with an increased robustness. The other difficulty to face is high temperature. Fibre optics with metal coating allows safe operation under temperatures up to 400 deg.C and even higher. But differential dilatation between silica and typical metallic material produces differential elongation in the range of 0.5 10{sup -2} i.e 5000{mu}{epsilon} for an increase in temperature of 300-400 deg. C. Such large elongation has to be considered carefully in the sensor design and its fixing on the sample. Laboratory tests with a second generation of adapted sensors demonstrated their good accuracy: less than 1% error over a displacement of 100{mu}m (< 1 {mu}m error), at room temperature. The displacement measured can reach 250{mu}m (20000{mu}{epsilon} with a gauge length of 12.5 mm) or more. We are currently implementing metal-coated fibre and we are preparing the next in pile irradiation on the BR2 reactor scheduled for mid-2011. Other applications of the sensor can be considered. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Kensor: Coordinated Intelligence from Co-Located Sensors

Internet of Things (IoT) is becoming more pervasive in many installations, including homes, manufacturing plants, and industrial facilities of all kinds. The data that IoT produces is a reflection of usual behavior such as daily routines and scheduled tasks, but also from unexpected behavior due to unintentional or undesirable abnormalities. Here, we focus on achieving coordinated intelligence about normal and abnormal phenomena from multiple sensors that are geographically colocated in close proximity, monitoring and controlling a set of co-located devices. Given a set of co-located sensors, we seek an intelligent approach that would automatically determine the “normal” patterns of behaviors among the correlated sensors. After normal behavior is extracted, later monitoring should detect any deviant variations over time. An example application is an entry monitoring and alert system for facilities such as nuclear reactors, where badge readers, door locks, lights, weight trackers and other co-located sensors at the entry point are collectively tracked. To address this problem, we identify the possible solution approach that can be used to solve its different variants. The implemented model is developed as a combination of rules and Markov Chain methods.

Kotevska, Olivera↗

Integration of Control Methods and Digital Twins for Advanced Nuclear Reactors

Advanced nuclear reactors offer a new set of features to energy generation, due to their ability to adapt to variable energy demand, operate autonomously, be deployed in rural locations and monitored remotely, afford compact size and lower power ratings, and rely on novel technologies to achieve safer operations. Thus, a requirement for the success of these reactors is the use of intelligent forms of control to track changing power demands, make autonomous decisions, and reduce the need for human involvement. Regulatory requirements pertaining to control of nuclear reactors could be met via historical means of control; however, these are not expected to enable the level of highly autonomous operations desired in advanced nuclear reactors. Historical control methods rely on both logical and high-performance (HP) control. These two types of control are usually used separately, with a human element being introduced whenever decisions are cascaded from one science to another. AI/ML control, on the other hand, can replace the human element in the current U.S. fleet of nuclear power plants (NPPs) by acting as a supervisory optimizer that understands the plant internal/external variables in order to make control decisions, and can easily handle non-linear and multi-input/multi out (MIMO) decisions—another requirement for advanced nuclear reactors that could be difficult to handle via logical and HP control. Because of the harsh operating environments produced in advanced reactors, resulting in the frequent failure of sensors and other types of equipment, and considering the lack of operating history for advanced nuclear reactors, control of advanced nuclear reactors would necessitate relying on a model that can track and adapt to the actual process (i.e., a digital twin). This digital twin can make approximations when knowledge and data are unavailable and would evolve as more knowledge is gained. The reactor control must also be risk-informed to account for the high-consequence nature of advanced reactors. This report introduces a high-level (i.e., not method- or process-specific) integration of the three different control and digital twinning methods able to meet the requirements for advanced nuclear reactors. These methods could be applied during both the operational and design stages of these reactors. The aim is to demonstrate how each method interfaces with and highlights enabling solutions necessitated by the unique features of advanced nuclear reactors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Shot-noise-limited magnetometer with sub-picotesla sensitivity at room temperature

We report a photon shot-noise-limited (SNL) optical magnetometer based on amplitude modulated optical rotation using a room-temperature {sup 85}Rb vapor in a cell with anti-relaxation coating. The instrument achieves a room-temperature sensitivity of 70 fT/√(Hz) at 7.6 μT. Experimental scaling of noise with optical power, in agreement with theoretical predictions, confirms the SNL behaviour from 5 μT to 75 μT. The combination of best-in-class sensitivity and SNL operation makes the system a promising candidate for application of squeezed light to a state-of-the-art atomic sensor.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Irradiation of ultrasonic sensors and adhesive couplants for application in light water reactor primary loop piping and components

The Electric Power Research Institute (EPRI) Nuclear Sector and US Department of Energy Light Water Reactor Sustainability Program are committed to engaging in research and development endeavors to address materials aging issues specific to long term operation of light water power reactors. To this effect, EPRI launched an industry initiative to develop nondestructive evaluation systems for online monitoring of existing cracks in light water reactor primary coolant loop piping and components. One of the goals of this initiative is to develop a sensor system (or systems) that can determine nondestructively if cracks are growing or arrested and, in the case of the former, to characterize their growth rates. A missing component of this initiative is an experimental assessment of how sensors and adhesive couplants will perform in service when exposed to chronic energetic neutron radiation, particularly at the primary coolant loop hot and cold leg dissimilar metal welds, which join the primary loop piping to the reactor pressure vessel and reside in the vicinity of the reactor core. The objective of this experimental study was to determine how ultrasonic transducers and adhesive couplants perform when exposed to irradiation in a test reactor to simulate and accelerate in-service exposure. Further, to achieve this objective, the signal stability of piezoelectric transducers and performance of adhesive couplants as a function of accumulated fast neutron fluence were characterized by collecting ultrasonic data in-situ during irradiation. Of particular interest were the ultrasonic signal quality and time decay of the amplitude of acoustic reflections as a function of fast neutron fluence. The results of the study showed that, of the 8 transducer/substrate sample assemblies tested, only 3 generated usable ultrasonic signals through the conclusion of the irradiation campaign. It was found that high temperature epoxy tends to ultrasonically couple the sensors to the substrates better than three types of refractory ceramic cements studied, as is supported by post irradiation examination. The results obtained through this experimental study will be utilized in the achievement of the overall goal of development of a sensor system to perform online monitoring of primary loop components.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

The 65 Elevated Risk Container Status Relative Humidity Measurements RFID RH/T Sensors in Containers [Slides]

In March of 2023, a memo was issued, drafted by the Container Management, Safety, and Engineering Team, identifying 65 elevated risk legacy containers for priority disposition at TA-55. These 65 were identified separately from the “typical” prioritization decision-making method used at TA-55 to disposition legacy items. This new technique gave important feedback and revealed improvement opportunities for the selection process of legacy containers for disposition. The DOE complex and TA-55 have a long history of nuclear operations and therefore the disposition of these legacy materials is vital.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Radiation Effects Considerations for Instrumentation and Control in Space Nuclear Systems

Radiation effects in electrical, electronic, electro-motive, and electro-optical (EEEE) hardware encompass a complex variety of interactions, processes, environments, and an evolving landscape of relevant hardware. Appropriately mitigating the effects of radiation in sensors, data acquisition, and control hardware is among the most significant challenges associated with deploying space nuclear power and propulsion systems. The expertise within EEEE radiation effects disciplines require working knowledge that is at least as complex and diverse as the problem itself, but that should not dissuade stakeholders and engineers in adjacent disciplines from attempting to understand the general principles associated with the problem at hand. This brief overview seeks to bring to the foreground a set of relevant topics that are of special importance for space nuclear propulsion applications that involve high rates of neutron and gamma radiation. The unique set of environments and design requirements for space nuclear systems mean that the experience and utility for methods applied to typical spaceflight hardware or terrestrial nuclear systems must not be applied naively. Forward consideration on the applicability of testing methods applied to either existing or bespoke hardware is likely to drive early decisions on system-wide radiation effects mitigation strategies, and will influence procurement requirements for providers of radiation tolerant hardware who are unlikely to have experience in this unique set of environments. Radiation hardness assurance (RHA) guidance should be adapted and emphasize the importance of hardware testing in the relevant environment. These must consider the combined effects of temperature, total ionizing dose (TID), non-ionizing/displacement damage (TNID/DD), and single event effects (SEE), and should consider the impacts of flux (rate) in addition to cumulative effects.

Radiation↗

Design and performance of silicon strip sensors with slim edges for HPS experiment

In this paper, we report on design and performance of new strip sensors for the Heavy Photon Search (HPS) experiment. The sensors feature a slim edge implementation using the Scribe–Cleave–Passivate (SCP) method. The slim edge design has allowed the introduction of a new layer closer to the target, which increased the tracking acceptance and vertex precision, improving physics reach of the experiment. We describe the production, testing, and operational experience with the new sensors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Neutron imaging with the short-pulse laser driven neutron source at the TRIDENT Laser Facility

Emerging approaches to short-pulse laser-driven neutron production offer a possible gateway to compact, low cost, and intense broad spectrum sources for a wide variety of applications. They are based on energetic ions, driven by an intense short-pulse laser, interacting with a converter material to produce neutrons via breakup and nuclear reactions. Recent experiments performed with the high-contrast laser at the Trident laser facility of Los Alamos National Laboratory have demonstrated a laser-driven ion acceleration mechanism operating in the regime of relativistic transparency, featuring a volumetric laser-plasma interaction. This mechanism is distinct from previously studied ones that accelerate ions at the laser-target surface. The Trident experiments produced an intense beam of deuterons with an energy distribution extending above 100 MeV. This deuteron beam, when directed at a beryllium converter, produces a forward-directed neutron beam with ~5x10 9 n/sr, in a single laser shot, primarily due to deuteron breakup. The neutron beam has a pulse duration on the order of a few nanoseconds with an energy distribution extending from a few hundreds of keV to almost 80 MeV. For the experiments on neutron-source spot-size measurements, our gated neutron imager was setup to select neutrons in the energy range of 2.5 to 35 MeV. The spot size of neutron emission at the converter was measured by two different imaging techniques, using a knife-edge and a penumbral aperture, in two different experimental campaigns. The neutron-source spot size is measured ~1 mm for both experiments. The measurements and analysis reported here give a spatial characterization for this type of neutron source for the first time. In addition, the forward modeling performed provides an empirical estimate of the spatial characteristics of the deuteron ion-beam. Finally, these experimental observations, taken together, provide essential yet unique data to benchmark and verify theoretical work into the basic acceleration mechanism, which remains an ongoing challenge.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Johnson Noise Thermometry for Advanced Small Modular Reactors

Temperature is a key process variable at any nuclear power plant (NPP). The harsh reactor environment causes all sensor properties to drift over time. At the higher temperatures of advanced NPPs the drift occurs more rapidly. The allowable reactor operating temperature must be reduced by the amount of the potential measurement error to assure adequate margin to material damage. Johnson noise is a fundamental expression of temperature and as such is immune to drift in a sensor s physical condition. In and near core, only Johnson noise thermometry (JNT) and radiation pyrometry offer the possibility for long-term, high-accuracy temperature measurement due to their fundamental natures. Small, Modular Reactors (SMRs) place a higher value on long-term stability in their temperature measurements in that they produce less power per reactor core and thus cannot afford as much instrument recalibration labor as their larger brethren. The purpose of this project is to develop and demonstrate a drift free Johnson noise-based thermometer suitable for deployment near core in advanced SMR plants.

Britton, Jr, Charles L.↗

Recovery of Silicon Carbide monitor irradiation temperature via continuous resistance measurement during annealing (Pt. II)

Silicon carbide (SiC) monitors provide a means of measuring peak irradiation temperature of experiment capsules in nuclear irradiation experiments. Neutron irradiation of a SiC monitor causes permanent lattice changes that are removed by annealing via heating to a temperature that exceeds the peak irradiation temperature. The annealing process results in changes to SiC physical characteristics that can be observed during the annealing process. This paper presents results of a method aimed at using electrical resistance, measured during a two-pass heating – cooling cycle as a means of recovering the irradiation temperature of a SiC monitor. Results indicate that the relationship between resistance and temperature of a SiC monitor shows a significant change in slope when the peak irradiation temperature is reached. This demonstrates the potential for this method to replace the current manual, and lengthy, process of post irradiation examination used to extract the peak irradiation temperature from irradiated SiC monitors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗