Search NASA⌕ Search

SEARCH · Search NASA

Results for “optical characterization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

Special Issue for the 9th International Conference on Carbonaceous Particles in the Atmosphere

Carbonaceous particles are a minor constituent of the atmosphere but have a profound effect on air quality, human health, visibility and climate. The importance of carbonaceous particles has been increasingly recognized and become a mainstream topic at numerous conferences. Such was not the case in 1978, when the 1st International Conference on Carbonaceous Particles in the Atmosphere (ICCPA), or ''Carbon Conference'' as it is widely known, was introduced as a new forum to bring together scientists who were just beginning to reveal the importance and complexity of carbonaceous particles in the environment. Table 1 lists the conference dates, venues in the series as well as the proceedings, and special issues resulting form the meetings. Penner and Novakov (Penner and Novakov, 1996) provide an excellent historical perspective to the early ICCPA Conferences. Thirty years later, the ninth in this conference series was held at its inception site, Berkeley, California, attended by 160 scientists from 31 countries, and featuring both new and old themes in 49 oral and 83 poster presentations. Topics covered such areas as historical trends in black carbon aerosol, ambient concentrations, analytic techniques, secondary aerosol formation, biogenic, biomass, and HULIS1 characterization, optical properties, and regional and global climate effects. The conference website, http://iccpa.lbl.gov/, holds the agenda, as well as many presentations, for the 9th ICCPA. The 10th ICCPA is tentatively scheduled for 2011 in Vienna, Austria. The papers in this issue are representative of several of the themes discussed in the conference. Ban-Weiss et al., (Ban-Weiss et al., accepted) measured the abundance of ultrafine particles in a traffic tunnel and found that heavy duty diesel trucks emit at least an order of magnitude more ultrafine particles than light duty gas-powered vehicles per unit of fuel burned. Understanding of this issue is important as ultrafine particles have been shown to adversely affect human health (Lighty et al., 2000; Pope and Dockery, 2006). Gan et al. (Gan et al., accepted) examined the indoor air quality aboard submarines and found that the diesel particulate matter concentrations exceeded the EPA 24 hour standard. Claeys et al. (Claeys et al., accepted) studied the importance and sources of secondary organic aerosol (SOA) in remote marine environment during a period of high biological activity. Methanesulphonate was the major SOA compound detected and there was no evidence for SOA from isoprene. The optical properties of gasoline and diesel vehicle particulate emissions and their relative contribution to radiative forcing was studied by Strawa et al. (Strawa et al., accepted).

54 ENVIRONMENTAL SCIENCES↗

Introducing an Absolute Cavity Pyrgeometer for Improving the Atmospheric Longwave Irradiance Measurement (Presentation)

Advancing climate change research requires accurate and traceable measurement of the atmospheric longwave irradiance. Current measurement capabilities are limited to an estimated uncertainty of larger than +/- 4 W/m2 using the interim World Infrared Standard Group (WISG). WISG is traceable to the Systeme international d'unites (SI) through blackbody calibrations. An Absolute Cavity Pyrgeometer(ACP) is being developed to measure absolute outdoor longwave irradiance with traceability to SI using the temperature scale (ITS-90) and the sky as the reference source, instead of a blackbody. The ACP was designed by NREL and optically characterized by the National Institute of Standards and Technology (NIST). Under clear-sky and stable conditions, the responsivity of the ACP is determined bylowering the temperature of the cavity and calculating the rate of change of the thermopile output voltage versus the changing net irradiance. The absolute atmospheric longwave irradiance is then calculated with an uncertainty of +/- 3.96 W/m2 with traceability to SI. The measured irradiance by the ACP was compared with the irradiance measured by two pyrgeometers calibrated by the WorldRadiation Center with traceability to the WISG. A total of 408 readings was collected over three different clear nights. The calculated irradiance measured by the ACP was 1.5 W/m2 lower than that measured by the two pyrgeometers that are traceable to WISG. Further development and characterization of the ACP might contribute to the effort of improving the uncertainty and traceability of WISG toSI.

47 OTHER INSTRUMENTATION↗

Introducing an Absolute Cavity Pyrgeometer (ACP) for Improving the Atmospheric Longwave Irradiance Measurement (Poster)

Advancing climate change research requires accurate and traceable measurement of the atmospheric longwave irradiance. Current measurement capabilities are limited to an estimated uncertainty of larger than +/- 4 W/m2 using the interim World Infrared Standard Group (WISG). WISG is traceable to the Systeme international d'unites (SI) through blackbody calibrations. An Absolute Cavity Pyrgeometer (ACP) is being developed to measure absolute outdoor longwave irradiance with traceability to SI using the temperature scale (ITS-90) and the sky as the reference source, instead of a blackbody. The ACP was designed by NREL and optically characterized by the National Institute of Standards and Technology (NIST). Under clear-sky and stable conditions, the responsivity of the ACP is determined by lowering the temperature of the cavity and calculating the rate of change of the thermopile output voltage versus the changing net irradiance. The absolute atmospheric longwave irradiance is then calculated with an uncertainty of +/- 3.96 W/m2 with traceability to SI. The measured irradiance by the ACP was compared with the irradiance measured by two pyrgeometers calibrated by the World Radiation Center with traceability to the WISG.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Introducing an Absolute Cavity Pyrgeometer (ACP) for Improving the Atmospheric Longwave Irradiance Measurement (Poster)

Advancing climate change research requires accurate and traceable measurement of the atmospheric longwave irradiance. Current measurement capabilities are limited to an estimated uncertainty of larger than +/- 4 W/m2 using the interim World Infrared Standard Group (WISG). WISG is traceable to the Systeme international d'unites (SI) through blackbody calibrations. An Absolute Cavity Pyrgeometer(ACP) is being developed to measure absolute outdoor longwave irradiance with traceability to SI using the temperature scale (ITS-90) and the sky as the reference source, instead of a blackbody. The ACP was designed by NREL and optically characterized by the National Institute of Standards and Technology (NIST). Under clear-sky and stable conditions, the responsivity of the ACP is determined bylowering the temperature of the cavity and calculating the rate of change of the thermopile output voltage versus the changing net irradiance. The absolute atmospheric longwave irradiance is then calculated with an uncertainty of +/- 3.96 W/m2 with traceability to SI. The measured irradiance by the ACP was compared with the irradiance measured by two pyrgeometers calibrated by the WorldRadiation Center with traceability to the WISG.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

High-fidelity Experiments of Turbulent Buoyant Jets from Simultaneous Particle Image Velocimetry and Laser Induced Fluorescence

Accurate models of turbulent buoyant flows are essential for the design of nuclear reactors thermal hydraulics and passive safety systems. However, available models fail to fully capture the physics of turbulent mixing when buoyancy becomes predominant with respect to momentum. Therefore, high-fidelity experiments of well-controlled fundamental flows are needed to develop and validate more accurate models. We performed experiments of positive and negative turbulent buoyant jets, both in uniform and stratified environments, with the aim of understanding the thermal hydraulics of turbulent mixing with variable density and providing high-fidelity data for the development and validation of turbulence models. Non-intrusive, simultaneous Particle Image Velocimetry and Laser Induced Fluorescence measurements were carried out to acquire instantaneous velocity and concentration fields on a vertical section parallel to the axis of a jet in the self-similar region. The Refractive Index Matching method was applied to measure high-resolution buoyant jets with up to 8.6% density difference. These data are free of the typical errors that characterize optical measurements of buoyancy driven flows (e.g., natural and mixed convection) where the refractive index of the fluid is inhomogeneous throughout the measurement domain. Turbulent statistics and entrainment of buoyant jets in uniform and stratified environments are presented. These data are compared with non-buoyant jets in uniform environment, as a reference to investigate the effects of buoyancy and stratification on turbulent mixing. The results will be used for the assessment of current turbulence models and as basis for the development of a new one that captures turbulent mixing.

42 ENGINEERING↗

Electronics from Nano-Cell Crystals

This report documents the progress during the past year of a project to uncover the fundamental charge transport mechanisms in organic materials, concentration on crystalline systems and in device configurations. The project has produced solid results in molecular synthesis, crystal growth, electrical and optical characterization. The team has reached out and is collaborating with external groups, and therefore leverages well the DOE funds. Of particular note is the discovery of a method to systematically dope rubrene in a field-effect-transistor device configuration. Previous work in conducting polymers demonstrated orders of magnitude enhancement of conductivity, but in conjunction with changing mobility. For active devices (such as FETs) operation, the mobility must be independent of carrier concentration. We have shown for the first time in an organic system, that the carrier concentration can be changed independently of the FET mobility. Thus we have achieved a similar level of carrier concentration control as is routinely found in inorganic semiconductors. This result will enable the field of organics to proceed faster towards high performance devices for logic and photovoltaic functionality.

01 COAL, LIGNITE, AND PEAT↗

Imaging Single ZnO Vertical Nanowire Laser Cavities using UV-Laser Scanning Confocal Microscopy

We report the fabrication and optical characterization of individual ZnO vertical nanowire laser cavities. Dilute nanowire arrays with interwire spacing>10 ?m were produced by a modified chemical vapor transport (CVT) method yielding an ideal platform for single nanowire imaging and spectroscopy. Lasing characteristics of a single vertical nanowire are presented, as well as high-resolution photoluminescence imaging by UV-laser scanning confocal microscopy. In addition, three-dimensional (3D) mapping of the photoluminescence emission performed in both planar and vertical dimensions demonstrates height-selective imaging useful for vertical nanowires and heteronanostructures emerging in the field of optoelectronics and nanophotonics.

36 MATERIALS SCIENCE↗

Exciton annihilation and dephasing dynamics in semiconducting single-walled carbon nanotubes

Semiconducting single-walled carbon nanotubes (SWNTs) are one of the most intriguing nanomaterials due to their large aspect ratios, size tunable properties, and dominant many body interactions. While the dynamics of exciton population relaxation have been well characterized, optical dephasing processes have only been exam- ined indirectly through steady-state measurements such as single-molecule spectroscopy that can yield highly variable estimates of the homogeneous linewidth. To bring clarity to these conflicting estimates, a time-domain measurement of exciton dephasing at an ensemble level is necessary. Using two-pulse photon echo (2PE) spec- troscopy, comparatively long dephasing times approaching 200 fs are extracted for the (6,5) tube species at room temperature. In this contribution, we extend our previous study of 2PE and pump-probe spectroscopy to low temperatures to investigate inelastic exciton-exciton scattering. In contrast to the population kinetics observed upon excitation of the second transition-allowed excitonic state (E22 ), our one-color pump-probe data instead shows faster relaxation upon cooling to 60 K when the lowest transition-allowed state (E11 ) is directly excited for the (6,5) tube species. Analysis of the kinetics obtained suggests that the observed acceleration of kinetic decay at low temperature originates from an increasing rate of exciton-exciton annihilation. In order to directly probe exciton-exciton scattering processes, femtosecond 2PE signal is measured as a function of excitation fluence and temperature. Consistent with the observed enhancement of exciton-exciton scattering and annihilation at low temperatures, the dephasing rates show a correlated trend with the temperature dependence of the population lifetimes extracted from one-color pump-probe measurements.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Video Scanning Hartmann Optical Tester (VSHOT) Uncertainty Analysis: Preprint

This purely analytical work is based primarily on the geometric optics of the system and shows sensitivities to various design and operational parameters. We discuss sources of error with measuring devices, instrument calibrations, and operator measurements for a parabolic trough test. In this paper, we include both the random (precision) and systematic (bias) errors for VSHOT testing and theircontributions to the uncertainty. The contributing factors that we considered in this study are target tilt, target face to laser output distance, instrument vertical offset, scanner tilt, distance between the tool and the test piece, camera calibration, and scanner/calibration.

14 SOLAR ENERGY↗

Ocean Optics Protocols for Satellite Ocean Color Sensor Validation: Inherent Optical Properties: Instruments, Characterizations, Field Measurements and Data Analysis Protocols - Volume 4

This document stipulates protocols for measuring bio-optical and radiometric data for the Sensor Intercomparison and Merger for Biological and Interdisciplinary Oceanic Studies (SIMBIOS) Project activities and algorithm development. The document is organized into 6 separate volumes as Ocean Optics Protocols for Satellite Ocean Color Sensor Validation, Revision 4. Volume I: Introduction, Background and Conventions; Volume II: Instrument Specifications, Characterization and Calibration; Volume III: Radiometric Measurements and Data Analysis Methods; Volume IV: Inherent Optical Properties: Instruments, Characterization, Field Measurements and Data Analysis Protocols; Volume V: Biogeochemical and Bio-Optical Measurements and Data Analysis Methods; Volume VI: Special Topics in Ocean Optics Protocols and Appendices. The earlier version of Ocean Optics Protocols for Satellite Ocean Color Sensor Validation, Revision 3 (Mueller and Fargion 2002, Volumes 1 and 2) is entirely superseded by the six volumes of Revision 4 listed above.

Mueller, J. L.↗

Optic probe for semiconductor characterization

Described herein is an optical probe (120) for use in characterizing surface defects in wafers, such as semiconductor wafers. The optical probe (120) detects laser light reflected from the surface (124) of the wafer (106) within various ranges of angles. Characteristics of defects in the surface (124) of the wafer (106) are determined based on the amount of reflected laser light detected in each of the ranges of angles. Additionally, a wafer characterization system (100) is described that includes the described optical probe (120).

47 OTHER INSTRUMENTATION↗

Comparing non-destructive 3D X-ray computed tomography with destructive optical microscopy for microstructural characterization of fiber reinforced composites

Due to their lightweight, relatively high stiffness properties, and formability into complex shapes, discontinuous fiber composites are advantageous for producing small and medium size components. Improved characterization techniques and post-processing methodologies are required for more reliable quantification of the microstructure and defect distributions in these materials, in order to employ model-based approaches to assess their structural integrity. This work compares a non-destructive X-ray approach with a destructive optical microscopy approach for characterizing the microstructural attributes, specifically the fiber volume fraction, porosity volume fraction, fiber orientation distribution, and fiber length distribution of discontinuous glass fibers in a polypropylene matrix. Additionally, a method for destructively determining the ambiguous components of the orientation tensor (related to the sign ambiguity of the out-of-plane angle in a destructive cross-sectional cut of a fiber) over a large surface area is included. It was found that fiber volume fraction and average fiber aspect ratio matched well, while fiber orientation and porosity detection had small but notable differences. The differences in the detection capabilities of each technique are quantified and discussed shedding light on the specific advantages and disadvantages of each approach, and enabling engineers to quantify uncertainty in their microstructural characterization measurements especially as they relate to model based structural integrity activities.

Non-destructive testing↗

Electrical, optical, and material characterizations of blue InGaN light emitting diodes submitted to reverse-bias stress in water vapor condition

In this paper, we investigate degradation of InGaN/GaN light emitting diodes (LEDs) under reverse-bias operations in water vapor and dry air. To examine failure origins, electrical characterizations including current-voltage, breakdown current profiles, optical measurement, and multiple material analyses were performed. Our findings indicate that the diffusion of indium atoms in water vapor can expedite degradation. Investigation of reverse-bias stress can help provide insight into the effects of water vapor on LEDs.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Characterization of quasi-optical filters with picosecond transient radiation

The broadband microwave transmission properties of quasi-optical components are characterized with optoelectronically generated, picosecond transient radiation. The polarization sensitivity of a lithographically fabricated wire grating, from 15-140 GHz, is presented. The complex transmission functions of two different uniform arrays of cross dipoles are measured and compared with theoretical predictions.

Arjavalingam, G.↗

Optical and electrical characterizations of laser-chemical-vapor-deposited aluminum oxynitride films

Composition-dependent optical and electrical properties of L-CVD (Al2O3)1-c-(AlN)c composite films are examined. The optical properties exhibit a continuous change from Al2O3 to AlN with increasing value of the composition parameter c from zero to one. There is a critical concentration value of about 0.3 below and above which Al2O3- and AlN-like optical properties are observed. The impurity absorption regions are 5.1-6.7 eV for Al2O32 and 4.6-6.0 for AlN, while the energy gap is about 6.7 eV for Al2O3 and 6.0 eV for AlN. The electrical properties of Al-insulator n-Si MIS structures display externally programmable states when bulk-controlled electron emission occurs from the traps. In the high-field region a persistent polarization field is established within the insulator. C-V characteristics of the samples are more sensitive to the concentration factor c than the I-V characteristics. A large clockwise hysteresis is observed for AlN, but a smaller counterclockwise one is observed for Al2O3.

Demiryont, H.↗

Optical Measurement Technique for Space Column Characterization

A simple optical technique for the structural characterization of lightweight space columns is presented. The technique is useful for determining the coefficient of thermal expansion during cool down as well as the induced strain during tension and compression testing. The technique is based upon object-to-image plane scaling and does not require any photogrammetric calibrations or computations. Examples of the measurement of the coefficient of thermal expansion are presented for several lightweight space columns. Examples of strain measured during tension and compression testing are presented along with comparisons to results obtained with Linear Variable Differential Transformer (LVDT) position transducers.

Barrows, Danny A.↗

Structural characterization and novel optical properties of defect chalcopyrite ZnGa{sub 2}Te{sub 4} thin films

Highlights: {yields} Preparation and characterization of ZnGa{sub 2}Te{sub 4} in powder and thin film forms. {yields} Structure properties such as XRD and EDX. {yields} Optical constant of the as-deposited ZnGa{sub 2}Te{sub 4} for the first time. {yields} Extraction of the optical parameters of the studied films. -- Abstract: Stoichiometric thin film samples of the ternary ZnGa{sub 2}Te{sub 4} defect chalcopyrite compound were prepared and characterized by X-ray diffraction technique. The elemental chemical composition of the prepared bulk material as well as of the as-deposited film was determined by energy-dispersive X-ray spectrometry. ZnGa{sub 2}Te{sub 4} thin films were deposited, by conventional thermal evaporation technique onto highly cleaned glass substrates. The X-ray and electron diffraction studies revealed that the as-deposited and the annealed ZnGa{sub 2}Te{sub 4} films at annealing temperature t{sub a} {<=} 548 K are amorphous, while those annealed at t{sub a} {>=} 573 K (for 1 h), are polycrystalline. The optical properties of the as-deposited films have been investigated for the first time at normal incidence in the spectral range from 500 to 2500 nm. The refractive index dispersion in the transmission and low absorption region is adequately described by the Wemple-DiDomenico single oscillator model, whereby, the values of the oscillator parameters have been calculated. The analysis of the optical absorption coefficient revealed an in-direct optical transition with energy of 1.33 eV for the as-deposited sample. This work suggested that ZnGa{sub 2}Te{sub 4} is a good candidate in solar cell devices as an absorbing layer.

36 MATERIALS SCIENCE↗