Search NASA⌕ Search

SEARCH · Search NASA

Results for “phantom”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

The impact of positron range on PET resolution, evaluated with phantoms and PHITS Monte Carlo simulations for conventional and non-conventional radionuclides

The increasing interest and availability of non-standard positron-emitting radionuclides has heightened the relevance of radionuclide choice in the development and optimization of new positron emission tomography (PET) imaging procedures, both in preclinical research and clinical practice. Differences in achievable resolution arising from positron range can largely influence application suitability of each radionuclide, especially in small-ring preclinical PET where system blurring factors due to annihilation photon acollinearity and detector geometry are less significant. Here, some resolution degradation can be mitigated with appropriate range corrections implemented during image reconstruction, the quality of which is contingent on an accurate characterization of positron range.

43 PARTICLE ACCELERATORS↗

Initial Image Quality and Clinical Experience with New CR Digital Mammography System: A Phantom and Clinical Study

The goal of the study was to evaluate the first CR digital mammography system ( registered Konica-Minolta) in Mexico in clinical routine for cancer detection in a screening population and to determine if high resolution CR digital imaging is equivalent to state-of-the-art screen-film imaging. The mammograms were evaluated by two observers with cytological or histological confirmation for BIRADS 3, 4 and 5. Contrast, exposure and artifacts of the images were evaluated. Different details like skin, retromamillary space and parenchymal structures were judged. The detectability of microcalcifications and lesions were compared and correlated to histology. The difference in sensitivity of CR Mammography (CRM) and Screen Film Mammography (SFM) was not statistically significant. However, CRM had a significantly lower recall rate, and the lesion detection was equal or superior to conventional images. There is no significant difference in the number of microcalcifications and highly suspicious calcifications were equally detected on both film-screen and digital images. Different anatomical regions were better detectable in digital than in conventional mammography.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Experimental study of transmission of a pulsed focused beam through a skull phantom in nonlinear regime

In the paper the use of receiving and radiating system, which allows to determine the parameters of bone by nonlinear pulse-echo technique and to image of brain structures through the skull bones, was proposed. Accuracy of the skull bone characterization is due to higher measured harmonic and is significantly better than in linear case. In the experimental part focused piezoelectric transducer with diameter 100 mm, focal distance 100 mm, the frequency of 1.092 MHz was used. It was shown that skull bone profiling can be performed with the use of 3rd harmonic since 1st harmonic can be used for visualization of the underlying objects. The use of wideband systems for both skull profiling and brain visualization is restricted by skull attenuation and resulting low effective sensitivity.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Fluorescence excitation and propagation through brain phantom gelatins: measurements and potential applications

We have investigated the utility of 0.6% agarose gels as surrogate materials for brain tissues in optical propagation studies for possible diagnostic and therapeutic applications. Centimeter-scale layers of the gel exhibited a Beer's law attenuation factor, , of 0.2 mm 1 for incident illumination via a pulsed LED (100 Hz) at 405 nm. This result was different by only about a factor of 3 from the effective penetration depth at similar wavelengths through in vitro samples of the gray (cortical) matter of human brain, as measured by others. Then, films of the thermographic phosphors La2O2S:Eu, Mg4FGeO6:Mn, YAG:Cr and variants of the latter were formed on aluminum substrates and the fluorescence of these samples was stimulated and observed through layers of the gel up to 4 cm thick. In all cases, the fluorescence was easily excited and distinguishable above the background. The results demonstrate that this gel might serve as an inexpensive and robust test bed for exploratory studies of neurological modalities involving propagation of optical signals within brain tissues.

60 APPLIED LIFE SCIENCES↗

Future singularity avoidance in phantom dark energy models

Different approaches to quantum cosmology are studied in order to deal with the future singularity avoidance problem. Our results show that these future singularities will persist but could take different forms. As an example we have studied the big rip which appear when one considers the state equation P = ωρ with ω < −1, showing that it does not disappear in modified gravity. On the other hand, it is well-known that quantum geometric effects (holonomy corrections) in loop quantum cosmology introduce a quadratic modification, namely proportional to ρ{sup 2}, in Friedmann's equation that replace the big rip by a non-singular bounce. However this modified Friedmann equation could have been obtained in an inconsistent way, what means that the obtained results from this equation, in particular singularity avoidance, would be incorrect. In fact, we will show that instead of a non-singular bounce, the big rip singularity would be replaced, in loop quantum cosmology, by other kind of singularity.

79 ASTRONOMY AND ASTROPHYSICS↗

Higher dimensional cosmological model with a phantom field

We consider a higher dimensional gravity theory with a negative kinetic energy scalar field and a cosmological constant. We find that the theory admits an exact cosmological solution for the scale factor of our universe. It has the feature that the universe undergoes a continuous transition from deceleration to acceleration at some finite time. This transition time can be interpreted as that of recent acceleration of our universe.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Chemical potential and the nature of dark energy: The case of a phantom field

The influence of a possible nonzero chemical potential {mu} on the nature of dark energy is investigated by assuming that the dark energy is a relativistic perfect simple fluid obeying the equation of state, p={omega}{rho} ({omega}<0, constant). The entropy condition, S{>=}0, implies that the possible values of {omega} are heavily dependent on the magnitude, as well as on the sign of the chemical potential. For {mu}>0, the {omega} parameter must be greater than -1 (vacuum is forbidden) while for {mu}<0 not only the vacuum but even a phantomlike behavior ({omega}<-1) is allowed. In any case, the ratio between the chemical potential and temperature remains constant, that is, {mu}/T={mu}{sub 0}/T{sub 0}. Assuming that the dark energy constituents have either a bosonic or fermionic nature, the general form of the spectrum is also proposed. For bosons {mu} is always negative and the extended Wien's law allows only a dark component with {omega}<-1/2, which includes vacuum and the phantomlike cases. The same happens in the fermionic branch for {mu}<0. However, fermionic particles with {mu}>0 are permitted only if -1<{omega}<-1/2. The thermodynamics and statistical arguments constrain the equation-of-state parameter to be {omega}<-1/2, a result surprisingly close to the maximal value required to accelerate a Friedmann-Robertson-Walker-type universe dominated by matter and dark energy ({omega} < or approx. -10/21)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Crossing the phantom divide with parametrized post-Friedmann dark energy

Dark energy models with a single scalar field cannot cross the equation of state divide set by a cosmological constant. More general models that allow crossing require additional degrees of freedom to ensure gravitational stability. We show that a parameterized post-Friedmann description of cosmic accelerzation provides a simple but accurate description of multiple scalar field crossing models. Moreover the prescription provides a well-controlled approximation for a wide range of 'smooth' dark energy models. It conserves energy and momentum and is exact in the metric evolution on scales well above and below the transition scale to relative smoothness. Standard linear perturbation tools have been altered to include this description and made publicly available for studies of the dark energy involving cosmological structure out to the horizon scale.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Quintessence and phantom dark energy from ghost D-branes

We present a novel dark-energy candidate, based upon the existence and dynamics of ghost D-branes in a warped compactification of type IIB string theory. Gp-branes cancel the combined BPS sectors of the Dp-branes, while they preserve the same supersymmetries. We show that this scenario can naturally lead to either quintessence or phantomlike behaviors, depending on the form of the involved potentials and brane tension. As a specific example we investigate the static, dark-energy dominated solution subclass.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Constraints on scalar phantoms

We update the constraints on the minimal model of dark matter, where a stable real scalar field is added to the standard model Lagrangian with a renormalizable coupling to the Higgs field. Once we fix the dark matter abundance, there are only two relevant model parameters, the mass of the scalar field and that of the Higgs boson. The recent data from the CDMS-II experiment have excluded a parameter region where the scalar field is light, such as less than about 50 GeV. In a large parameter region, the consistency of the model can be tested by the combination of future direct detection experiments and the LHC experiments.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Performance evaluation of an improved optical computed tomography polymer gel dosimeter system for 3D dose verification of static and dynamic phantom deliveries

The performance of a next-generation optical computed tomography scanner (OCTOPUS-5X) is characterized in the context of three-dimensional gel dosimetry. Large-volume (2.2 L), muscle-equivalent, radiation-sensitive polymer gel dosimeters (BANG-3) were used. Improvements in scanner design leading to shorter acquisition times are discussed. The spatial resolution, detectable absorbance range, and reproducibility are assessed. An efficient method for calibrating gel dosimeters using the depth-dose relationship is applied, with photon- and electron-based deliveries yielding equivalent results. A procedure involving a preirradiation scan was used to reduce the edge artifacts in reconstructed images, thereby increasing the useful cross-sectional area of the dosimeter by nearly a factor of 2. Dose distributions derived from optical density measurements using the calibration coefficient show good agreement with the treatment planning system simulations and radiographic film measurements. The feasibility of use for motion (four-dimensional) dosimetry is demonstrated on an example comparing dose distributions from static and dynamic delivery of a single-field photon plan. The capability to visualize three-dimensional dose distributions is also illustrated.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Optical observation of energy loss distribution and practical range of positrons from a {sup 18}F water solution in a water-equivalent phantom

The energy loss distribution of {beta}{sup +} particles is closely related to their maximum penetration depth distribution and annihilation point distribution. The latter is of practical importance for positron emission tomography. Experimental data related to the energy loss distribution are important for comprehensive validation of physics and simulation models of {beta}{sup +} interactions. In this paper the authors present a new experimental approach that allows them to visually observe the {beta}{sup +} energy loss distribution of a solution of nuclear medicine radioisotopes in a plastic scintillator using an optical camera. The authors also report a set of the first experimental results. A water solution of {sup 18}F was localized in a small hole in a plastic scintillator (BC430). Optical imaging of the scintillator yielded visual images of the energy loss distribution with a submillimeter resolution. The radial dependence in the energy distribution was quantitatively measured by analysis of the images, and exponential fitting parameters were obtained. The authors observed that the results of Monte Carlo simulation with EGS5 (version 1.0.2) and GEANT4 (version 4.9.01.p01) were consistent with those obtained experimentally. The results of the Monte Carlo simulation indicated that for a linear scale, the energy loss distribution in the scintillator was approximately the same as that in water, and the relative shape of the energy loss distribution was close to those of the maximum penetration depth distribution and annihilation point distribution. This paper also presents discussions about the further possibilities of this optical imaging approach. Thus, optical observation of the {beta}{sup +} energy loss distribution in a scintillator is a promising technique for visual and quantitative experimental studies of {beta}{sup +} emission from a solution of radioisotopes that are used in nuclear medicine.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

MRI of prostate brachytherapy seeds at high field: A study in phantom

Postimplant evaluation of prostate brachytherapy using magnetic resonance imaging (MRI) at 1.5 T has met with some difficulties due to the uncertainty associated with seed localization despite the excellent anatomical delineation this imaging modality can achieve. Seeds in vascularized regions or outside the prostate, where signal heterogeneity or drop off can obscure their position, can be difficult to identify. The increase in SNR available at 3.0 T offers the potential to improve these issues with visualization. However, before moving directly to in vivo studies, it is important to investigate the effects of artifact size on the ability to localize multiple seeds in close proximity. These artifacts are of extra concern at higher field because of the increased induced field distortions surrounding the seeds. A single prostate brachytherapy seed (IMC6711, OncoSeed) and arrays of seed pairs were suspended in a porcine gel medium and imaged on 1.5 and 3 T MRI scanners for comparison. Two basic acquisition techniques utilized in a wide array of clinical sequences [spin-echo based and gradient-echo (GE) based] were investigated for the types of artifacts they produce, and their dependence on field. Analysis of the resulting voids was performed to determine the relative size of seeds as seen on the images, as well as the ability to distinguish seeds at close proximity. The seed voids at 3 T were only slightly larger than those obtained at 1.5 T (0.5 mm longer and wider) when using a spin-echo type sequence. For this work, the authors used a proton density fast spin-echo (FSE) sequence. These results are promising for the use of 3 T imaging for postimplant evaluation since the SNR will increase by roughly a factor of 2 with only a limited corresponding increase in artifact size. The minimum separation of the seeds to be completely distinguished using void analysis increased from between 1.5 and 3 mm to between 3 and 4.5 mm when going from 1.5 to 3 T FSE imaging. The minimum separation of the seeds for GE at the demonstration TE of 11 ms was found to be between 3 and 4.5 mm for 1.5 T and between 4.5 and 6 mm for 3 T. These GE artifact dimensions will scale down with TE and, as this happens, approach the dimensions of the FSE artifacts given above.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Monte Carlo dosimetry for {sup 103}Pd, {sup 125}I, and {sup 131}Cs ocular brachytherapy with various plaque models using an eye phantom

Purpose: To investigate dosimetry for ocular brachytherapy for a range of eye plaque models containing{sup 103}Pd, {sup 125}I, or {sup 131}Cs seeds with model-based dose calculations. Methods: Five representative plaque models are developed based on a literature review and are compared to the standardized COMS plaque, including plaques consisting of a stainless steel backing and acrylic insert, and gold alloy backings with: short collimating lips and acrylic insert, no lips and silicone polymer insert, no lips and a thin acrylic layer, and individual collimating slots for each seed within the backing and no insert. Monte Carlo simulations are performed using the EGSnrc user-code BrachyDose for single and multiple seed configurations for the plaques in water and within an eye model (including nonwater media). Simulations under TG-43 assumptions are also performed, i.e., with the same seed configurations in water, neglecting interseed and plaque effects. Maximum and average doses to ocular structures as well as isodose contours are compared for simulations of each radionuclide within the plaque models. Results: The presence of the plaque affects the dose distribution substantially along the plaque axis for both single seed and multiseed simulations of each plaque design in water. Of all the plaque models, the COMS plaque generally has the largest effect on the dose distribution in water along the plaque axis. Differences between doses for single and multiple seed configurations vary between plaque models and radionuclides. Collimation is most substantial for the plaque with individual collimating slots. For plaques in the full eye model, average dose in the tumor region differs from those for the TG-43 simulations by up to 10% for{sup 125}I and {sup 131}Cs, and up to 17% for {sup 103}Pd, and in the lens region by up to 29% for {sup 125}I, 34% for {sup 103}Pd, and 28% for {sup 131}Cs. For the same prescription dose to the tumor apex, the lowest doses to critical ocular structures are generally delivered with plaques containing {sup 103}Pd seeds. Conclusions: The combined effects of ocular and plaque media on dose are significant and vary with plaque model and radionuclide, suggesting the importance of model-based dose calculations employing accurate ocular and plaque media and geometries for eye plaque brachytherapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Optimizing cone beam CT scatter estimation in egs-cbct for a clinical and virtual chest phantom

Purpose: Cone beam computed tomography (CBCT) image quality suffers from contamination from scattered photons in the projection images. Monte Carlo simulations are a powerful tool to investigate the properties of scattered photons.egs-cbct, a recent EGSnrc user code, provides the ability of performing fast scatter calculations in CBCT projection images. This paper investigates how optimization of user inputs can provide the most efficient scatter calculations. Methods: Two simulation geometries with two different x-ray sources were simulated, while the user input parameters for the efficiency improving techniques (EITs) implemented inegs-cbct were varied. Simulation efficiencies were compared to analog simulations performed without using any EITs. Resulting scatter distributions were confirmed unbiased against the analog simulations. Results: The optimal EIT parameter selection depends on the simulation geometry and x-ray source. Forced detection improved the scatter calculation efficiency by 80%. Delta transport improved calculation efficiency by a further 34%, while particle splitting combined with Russian roulette improved the efficiency by a factor of 45 or more. Combining these variance reduction techniques with a built-in denoising algorithm, efficiency improvements of 4 orders of magnitude were achieved. Conclusions: Using the built-in EITs inegs-cbct can improve scatter calculation efficiencies by more than 4 orders of magnitude. To achieve this, the user must optimize the input parameters to the specific simulation geometry. Realizing the full potential of the denoising algorithm requires keeping the statistical uncertainty below a threshold value above which the efficiency drops exponentially.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗