Search NASA⌕ Search

SEARCH · Search NASA

Results for “power simulation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

CAPE-OPEN compliant stochastic modeling and reduced-order model computation capability for APECS system

APECS (Advanced Process Engineering Co-Simulator) is an integrated software suite that combines the power of process simulation with high-fidelity, computational fluid dynamics (CFD) for improved design, analysis, and optimization of process engineering systems. The APECS system uses commercial process simulation (e.g., Aspen Plus) and CFD (e.g., FLUENT) software integrated with the process-industry standard CAPE-OPEN (CO) interfaces. This breakthrough capability allows engineers to better understand and optimize the fluid mechanics that drive overall power plant performance and efficiency. The focus of this paper is the CAPE-OPEN complaint stochastic modeling and reduced order model computational capability around the APECS system. The usefulness of capabilities is illustrated with coal fired, gasification based, FutureGen power plant simulation. These capabilities are used to generate efficient reduced order models and optimizing model complexities.

01 COAL, LIGNITE, AND PEAT↗

Test Results from a Direct Drive Gas Reactor Simulator Coupled to a Brayton Power Conversion Unit

Component level testing of power conversion units proposed for use in fission surface power systems has typically been done using relatively simple electric heaters for thermal input. These heaters do not adequately represent the geometry or response of proposed reactors. As testing of fission surface power systems transitions from the component level to the system level it becomes necessary to more accurately replicate these reactors using reactor simulators. The Direct Drive Gas-Brayton Power Conversion Unit test activity at the NASA Glenn Research Center integrates a reactor simulator with an existing Brayton test rig. The response of the reactor simulator to a change in Brayton shaft speed is shown as well as the response of the Brayton to an insertion of reactivity, corresponding to a drum reconfiguration. The lessons learned from these tests can be used to improve the design of future reactor simulators which can be used in system level fission surface power tests.

Hervol, David S.↗

Rancor Microworld Simulation Environment for Nuclear Process Control

The Rancor Microworld is a simplified nuclear power plant simulator. It represents the process of an integrated pressurized light water reactor core with a secondary Rankine cycle turbine/generator. The reactor core is governed by simplified core physics. Operators have the ability to raise and lower control rods to change the reactivity and consequently generate more or less electricity. The microworld provides a digital human machine interface for operating and monitoring the plant efficiently to maximize profits within the simulation. The simulation supports multi-unit operations analogous to small modular reactor plants and supports faults on various components within each unit to simulate some common training scenarios such as reactor and turbine trip events. The microworld includes experimental modules to log process parameters and both automated and user control inputs and events, administer situation awareness probes, and interface with eye tracking software.

Ulrich, ThomasA.↗

Optimized allocation method of the VSC-MTDC system for frequency regulation reserves considering the cost

In recent years, the interconnection of asynchronous power grids through the VSC-MTDC system has been proposed and extensively studied in light of the potential benefits of economical bulk power exchanges and frequency regulation reserves sharing. This paper proposed an optimized allocation method for sharing frequency regulation reserves among the interconnected power systems and the corresponding frequency regulation control of the VSC-MTDC system under emergency frequency deviation events. Firstly, the frequency regulation reserve classification is proposed. In the classification, the available frequency response capacity reserves of each interconnection are divided into commercial reserves and regular reserves. While the commercial reserves are procured through long-term contracts, the regular reserves are purchased based on market prices of frequency regulation services. Secondly, based on the proposed frequency regulation reserve classification, a novel frequency regulation control is then introduced for the VSC-MTDC system. This control method could minimize the costs of the disturbed power grid for the needed frequency response supports from the other power grids. Simulation verifications are performed on a modified IEEE 39 bus system and a highly reduced power system model representing the North American grids. The simulation verification indicates that the developed frequency regulation control significantly reduced ancillary service costs of the disturbed power grid.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Experiments and numerical simulations on high-density magnetohydrodynamic electrical power generation

We describe experiments and numerical simulations on high-density energy conversion using a compact closed-cycle magnetohydrodynamic electrical power generator, where shock-tube-based experiments and quasi-three-dimensional numerical simulations are fully coupled. The temporal plasma-fluid behavior, the one- and two-dimensional plasma-fluid structures, the enthalpy-entropy diagram, the Hall voltage-Hall current characteristics, and the quality of the energy conversion efficiency are investigated. The slightly divergent channel configuration, the application of high- and uniform-density magnetic flux to the entire generator, the high electrical conductivity, the symmetric plasma structure and stable plasma behavior, and the sufficient pressure gradient used to drive the fluid overcome the disadvantages of the generator due to its compactness, and markedly improve its energy conversion performance, namely, a power density of 0.76 GW/m{sup 3}, an isentropic efficiency of 51%, and an enthalpy extraction ratio of 17.0%.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Cybersecurity for Electric Vehicle Fast-Charging Infrastructure

The integration of electric vehicles (EVs) into electric grid operations can potentially leave the grid vulnerable to cyberattacks from both legacy and new equipment and protocols, including extreme fast-charging infrastructure. This paper introduces a co-simulation platform to perform cyber vulnerability analysis of EV charging infrastructure and its dependencies on communications and control systems. Grid impact scenarios through linkages to power system simulation tools such as OpenDSS and vehicle infrastructure-specific attack paths are discussed. An adaptive platform that assists with predicting and solving evolving cybersecurity challenges is demonstrated with a cyber-energy emulation that accelerates the analysis of cyberattacks and system behavior.

47 OTHER INSTRUMENTATION↗

Integrating PCTRAN with AI-Driven Host-Intrusion Detection and Secured Container Systems for Advanced Malware Analysis (Summer Internship Report)

This study presents a solution for enhancing the security of the Personal Computer Transient Analyzer (PCTRAN) PC-based Nuclear Power Plant Simulator by integrating the software with an artificial intelligence (AI)-driven host-intrusion detection system (HIDS), in addition to a secured container system, for malware analysis. PCTRAN is a Windows XP-based software package that has the ability to simulate a variety of accident and transient conditions for nuclear power plants (NPPs). It offers a high-resolution replica of the Nuclear Steam Supply System (NSSS) and displays the status of important parameters allowing for operator interaction. By including AI-driven HIDS for the NSSS, the framework can identify security threats in real-time, ensuring the integrity of the nuclear simulation environment. Additionally, the secured container system offers the ability to isolate and analyze malware, preventing potential threats from affecting core systems. The integration process involves extensive testing and validation in order to ensure accuracy, reliability, and compliance with security policies. This framework sets a new precedent for secure simulation and training in NPP operations, and offers insight for future advancements in cybersecurity.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

PV Inverter Fault Response Including Momentary Cessation, Frequency-Watt, and Virtual Inertia

This paper presents two photovoltaic (PV) inverter control methods and an analysis of the two under a significant three-phase transmission line fault contingencies in the Hawaiian island of Oahu power system. Simulations are presented for the two control methods on the island power system with a high penetration of PV generation, approximately 40% of the total. The two control methods discussed are similar: one is a proportional frequency-watt controller, and the second is a proportional-derivative controller, a frequency-watt controller with virtual inertia. Both methods can be beneficial for fast frequency support. The inverter model also emulates inverter fault response including 'momentary cessation' and recovery during low voltage events. The study presented in this paper utilizes a validated power system model of the Hawaiian island of Oahu, modified to include PV resources with the two custom developed control models. Dynamic simulations with PSS/E are presented during a significant transmission line three-phase fault contingency. Simulations are presented with and without PV reserve margin. In addition, a parameter sensitivity analysis is presented for the control methods. Results indicate both methods can significantly improve system response during fault events. Findings indicate that transmission faults can produce severe frequency events, and that fast recovery from momentary cessation is crucial to mitigate severity.

14 SOLAR ENERGY↗

Hybrid simulation of electrode plasmas in high-power diodes

New numerical techniques for simulating the formation and evolution of cathode and anode plasmas have been successfully implemented in a hybrid code. The dynamics of expanding electrode plasmas has long been recognized as a limiting factor in the impedance lifetimes of high-power vacuum diodes and magnetically insulated transmission lines. Realistic modeling of such plasmas is being pursued to aid in understanding the operating characteristics of these devices as well as establishing scaling relations for reliable extrapolation to higher voltages. Here, in addition to kinetic and fluid modeling, a hybrid particle-in-cell technique is described that models high density, thermal plasmas as an inertial fluid which transitions to kinetic electron or ion macroparticles above a prescribed energy. The hybrid technique is computationally efficient and does not require resolution of the Debye length. These techniques are first tested on a simple planar diode then applied to the evolution of both cathode and anode plasmas in a high-power self-magnetic pinch diode. The impact of an intense electron flux on the anode surface leads to rapid heating of contaminant material and diode impedance loss.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Evaluating the Impact of Price-Responsive Load on Power Systems Using Integrated T&D Simulation

This paper explores the differences between simulating price-responsive load (PRL) interactions with power systems using integrated transmission and distribution (T&D) models and transmission-only (T-only) models. This analysis uses the Integrated Grid Modeling System (IGMS) software to capture 'ISO-to-appliance' simulations using a synthetic T&D model built on the PJM 5-Bus transmission network with multiple full-scale taxonomy feeders that include physics-based models of thousands of customers and PRLs. The results show important differences in the impacts of PRLs between integrated T&D and T-only models. Experiments with the synthetic integrated T&D dataset demonstrated that integrated T&D simulation revealed notably larger differences between the PRL and no-PRL cases for load, and prices compared to T-only simulation. Similarly, differences are observed between the price response of individual buildings and distribution feeders and the corresponding transmission bus in the integrated T&D simulations, which are difficult to capture in traditional T-only simulations.

24 POWER TRANSMISSION AND DISTRIBUTION↗

FNCS: A Framework for Power System and Communication Networks Co-Simulation

This paper describes the Fenix framework that uses a federated approach for integrating power grid and communication network simulators. Compared existing approaches, Fenix al- lows co-simulation of both transmission and distribution level power grid simulators with the communication network sim- ulator. To reduce the performance overhead of time synchro- nization, Fenix utilizes optimistic synchronization strategies that make speculative decisions about when the simulators are going to exchange messages. GridLAB-D (a distribution simulator), PowerFlow (a transmission simulator), and ns-3 (a telecommunication simulator) are integrated with the frame- work and are used to illustrate the enhanced performance pro- vided by speculative multi-threading on a smart grid applica- tion. Our speculative multi-threading approach achieved on average 20% improvement over the existing synchronization methods

Co-simulation↗

Update of Residential Load Profile for WECC Load Composition Model Using Cross-Correlation Method

The Western Electricity Coordinating Council (WECC) initiated the development of a composite load model for transmission-level power system simulators. To more precisely utilize the model to represent the power consumption pattern for various locations of the WECC network, an up-to-date load composition dataset is required. The study in this paper aims to reconstruct the residential sector of the load composition model (LCM) dataset using latest survey or measurement data. The LCM residential dataset contains load profiles for twelve climate zones and five season types. The northwest energy efficiency alliance (NEEA) launched a study to generate the load profiles for four climate zones in the Pacific Northwest. Based on the NEEA database, a component-wise cross-correlation-based approach has been developed in this paper to update the obsolete residential load profiles of the four pacific northwest climate zones and populate the new load shape data into the other eight climate zones.

Liu, Yuan↗

Frequency Regulation and Oscillation Damping Contributions of Variable-Speed Wind Generators in the U.S. Eastern Interconnection (EI)

The U.S. Eastern Interconnection (EI) is one of the largest electric power grids in the world and is expected to have difficulties in dealing with frequency regulation and oscillation damping issues caused by the increasing wind power. On the other side, variable-speed wind generators can actively engage in frequency regulation or oscillation damping with supplementary control loops. This paper creates a 5% wind power penetration simulation scenario based on the 16 000-bus EI system dynamic model and developed the user-defined wind electrical control model in PSS (R) E that incorporates additional frequency regulation and oscillation damping control loops. We evaluated the potential contributions of variable-speed wind generations to the EI system frequency regulation and oscillation damping, and simulation results demonstrate that current and future penetrations of wind power are promising in the EI system frequency regulation and oscillation damping.

17 WIND ENERGY↗

RANS Simulation of the Heave Response of a Two-Body Floating Point Wave Absorber: Preprint

A preliminary study on a two-body floating wave absorbers is presented in this paper. A Reynolds-Averaged Navier-Stokes computational method is applied for analyzing the hydrodynamic heave response of the absorber in operational wave conditions. The two-body floating wave absorber contains a float section and a submerged reaction section. For validation purposes, our model is first assumed to belocked. The two sections are forced to move together with each other. The locked single body model is used in a heave decay test, where the RANS result is validated with the experimental measurement. For the two-body floating point absorber simulation, the two sections are connected through a mass-spring-damper system, which is applied to simulate the power take-off mechanism under design waveconditions. Overall, the details of the flow around the absorber and its nonlinear interaction with waves are investigated, and the power absorption efficiency of the two-body floating wave absorber in waves with a constant value spring-damper system is examined.

17 WIND ENERGY↗

Enhanced dynamic contingency analysis for power systems

The present disclosure describes systems and techniques that enhance effectiveness and efficiency of a contingency analysis tool that is used for studying the magnitude and likelihood of extreme contingencies and potential cascading events across a power system. The described systems and techniques include deploying the contingency analysis tool in a high-performance computing (HPC) environment and incorporating visual situational awareness approaches to allow power system engineers to quickly and efficiently evaluate multiple power system simulation models. Furthermore, the described systems and techniques include the power system contingency-analysis tool calculating and coordinating protection element settings, as well as assessing controls of the power system using small-signal nomograms, allowing power system engineers to more effectively comprehend, evaluate, and analyze causes and effects of cascading events against a topology of a power system.

Samaan, Nader A.↗

Optimization and Experimental Validation of Annular Finned PCM-HX for a Domestic Hot Water Heater Application

The load profile for domestic water heating is time-dependent and can result in high energy demand during peak operating times. Shifting this peak load can have significant environmental and economic impacts. Phase change material (PCM)-based thermal energy storage (TES) is a potentially useful technology for peak load shifting in domestic hot water (DHW) applications thanks to its high latent heat and energy density. In this study, an annular finned-tube PCM-HX design concept was optimized for a load-shifting TES unit to meet the Department of Energy standard for a medium-usage DHW heater using a resistance-capacitance model (RCM) integrated with a Multi-Objective Genetic Algorithm. The optimized design comprised 70 identical annular finned-tube PCM-HX units connected in parallel and utilizing RT62HC as the PCM. A single PCM-HX unit was prototyped and tested in a vertically oriented setup with upward heat transfer fluid (HTF) flow. The hot water supply time was defined based on a cutoff temperature of 51.7°C. The as-designed mass flow rate (1.5 g/s) was tested to assess the performance of the prototyped PCM-HX unit for RCM validation. For the experimental investigation, RTD sensor bundles measured HTF temperature at the PCM-HX inlet and outlet, and a Coriolis flow meter accurately measured the HTF mass flow rate. The simulated discharging power underpredicted the experimental result by about 12%, and the simulated hot water supply time underpredicted the experimental result by approximately 13% for the as-designed mass flow rate (1.5 g/s). The average deviation of the hot water supply temperature between the experimental and RCM results during the complete PCM solidification process was 1.3 K for the as-designed mass flow rate. The overall good agreement between the experimental and RCM results provides confidence that computationally efficient models such as RCM can be utilized for design optimization of PCM-HXs.

42 ENGINEERING↗

Outdoor Test Bed Performance of a Power Line Sensor Using a Real-Time Event Simulator

This report summarizes the design and application of an outdoor power line sensor testbed (OPLST) with a real-time simulator and power meter to compare a potential transformer (PT) and current transformer (CT) versus an advanced line-post sensor. The OPLST was created to validate advanced medium-voltage (20/34.5 kV) outdoor power line sensors used in electrical distribution systems. Electrical utilities have installed metering and relay-protection transformers like PTs and CTs for several decades. The PTs/CTs are iron core measurement transformers based on the electromagnetic induction principle and provide reliable data in normal grid operation. However, new outdoor power line sensors (OPLS) using other technologies like voltage divider, Rogowski coil and optical principles have become available and may have favorable performance and costs compared to PTs/CTs. Therefore, the importance of testing these technologies with the PT/CT, to compare the measured phase voltage/current at different power grid scenarios is crucial to understand the performance of these new OPLS. For this study a G&W Electric Model CVS-36-O power line sensor was chosen as the OPLS to test with voltage/current signals. An OPAL-RT Technologies Model OP4510 real-time simulator and Schweitzer Engineering Laboratories Model SEL-735 power meter were installed with the 20/34.5 kV OPLST to compare the measured transient events collected from an advanced OPLS and the PT/CT. This system is installed at the Distributed Energy Communications and Control (DECC) lab, Oak Ridge National Laboratory (ORNL). The simulator generated different power grid scenarios (electrical faults, capacitor bank operation, service restoration, etc.), and its analog-output signals were connected to the voltage/current amplifiers that feed the 20/34.5 kV aerial cable loop through the PT/CT devices. Additional PT/CT devices were also wired with the medium voltage aerial cable loop to measure the phase current/voltage signals and server as references. After each test, common format for transient data exchange (COMTRADE) files were collected from the SEL-735 power meter and used to compare the performance of the OPLS with the PT/CT. The behavior of analog signals, harmonic components, total harmonic distortion and crest factors were assessed and found favorable for the G&W sensor as compared to the reference PT/CT.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Cooperative Research and Development Agreement among National Energy Technology Laboratory, The Board of Regents of the University System of Georgia by and on behalf of Georgia Institute of Technology, and University of Texas at El Paso [Abstract]

Georgia Institute of Technology (GIT), University of Texas at El Paso (UTEP), and the National Energy Technology Laboratory (NETL) will collaborate and develop cyber-physical systems for advanced power systems. GIT will test virtual models on hybrid power system hardware and cyber physical components. UTEP will test novel actuators on hybrid power system hardware. NETL will access GIT’s expertise in the engineering and real time simulation of power system processes for cyber-physical systems and simulations to control hardware. NETL will establish a relationship to promote UTEP’s capabilities in additive manufacturing and high-temperature piezo-electric devices with the potential for controlling high-temperature flows with a light and inexpensive device at high response rates. This project is the result of an EERE Advanced Manufacturing Office open Multi-Topic awarded proposal led by GIT titled, “Robust Combined Heat and Hybrid Power (CHHP) for High Electrical Efficiency Cogeneration”.

42 ENGINEERING↗