Search NASA⌕ Search

SEARCH · Search NASA

Results for “pressure sensor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

563 records · Page 32

2D-EFICACY: Control of Metastable 2D Carbide Chalcogenide Heterolayers: Strain and Moire Engineering

The experimental isolation of graphene led to the discovery of an entirely new world of two-dimensional (2D) materials in which the 2D nature often leads to emergent behaviors not seen in bulk systems. 2D transition metal dichalcogenides (TMDs) exhibit physico-chemical properties that depend on the transition metal, polymorph, thickness, and presence and type of defects. Recently, a group of thin (10-100nm) transition metal carbides (TMCs), such as Mo 2 C, has been synthesized that exhibit a thickness-dependent superconducting critical temperature (Tc). These thin TMCs are different from MXenes, another class of 2D materials consisting of few layers of nitrides or carbides (<5nm) produced by chemical etching and delamination. The goal of this renewal proposal is to combine experiment and computation to synthesize and elucidate the guiding principles that control the growth, orientation and strain of heterostacks of thin TMCs and TMDs composed with Nb, Ti and W. We expect to stabilize metastable hybrid phases of TMCs sandwiched between TMDs (H-TMD/Cs) with unprecedented physico-chemical properties. As part of previous DOE-funded work by the Terrones/Sinnott groups, thin (10-100 nm thick) Mo 2 C flakes were successfully synthesized by chemical vapor deposition (CVD). By subsequently exposing Mo 2 C to H 2 S, partial chalcogenization was achieved, resulting in heterostacks of MoCx phases and MoS 2 . The formation of MoS 2 led to a deficiency of Mo atoms in the underlying Mo 2 C, resulting in an inhomogeneous phase change from α-Mo 2 C to γ’-MoCx and then to γ-MoC. The γ’-MoCx is a strained metastable phase and the heterostack of all three phases demonstrated an increased Tc relative to that of α-Mo 2 C, from 4 to 6K; its interleaved layered structure consisting of superconducting and semiconducting phases is ideal for future studies of Josephson junction series arrays. Moiré patterns in these heterostacked systems could result in new phenomena, as moiré patterns in bilayer graphene showed unconventional superconductivity and moiré excitons have been observed in twisted TMD heterobilayers. The scientific hypothesis of the proposed synergistic computational and experimental research is that orientation and strain control within confined thin metastable TMCs, sandwiched by stable phases of TMCs and layered TMDs, will depend on kinetic and thermodynamic “knobs” that include fast temperature changes, chalcogen diffusion through preferred crystallographic planes, reaction times, pressure, reactive atmosphere, precursors, and surfactants, which will also tailor properties such as superconductivity, magnetism, ferroelectricity, piezoelectricity, and catalytic performance. We will develop the guiding principles for the synthesis and stabilization of metastable H-TMD/Cs based on Nb, Ti and W. In order to validate the hypothesis, four tasks are proposed: The first task will synthesize ultra-thin TMCs based on Nb, W and Ti, by: 1) adapting the CVD method used for Mo 2 C, 2) plasma assisted CVD, 3) defect-mediated CVD processes, and 4) cryo-milling of carbide powders. The second task will accomplish the synthesis and basic physico-chemical characterizations of H-TMD/Cs by chalcogenization of the materials synthesized in task one, and by carbonization of TMDs. H-TMD/Cs will also be investigated for their suitability in energy conversion applications such as supercapacitors, Li and multivalent ion batteries, and electrocatalysts, topics of interest to DoE. These tasks will be carried out in close conjunction with density functional theory (DFT) calculations with insights into energetics, lattice parameters, stability, phase diagrams, band structures, and density of states of H-TMD/Cs. The third task will characterize and evaluate strain and moiré patterns at the interfaces of different H-TMD/Cs by high-resolution scanning transmission electron microscopy (HR-STEM), scanning tunneling microscopy (STM), and conductive tip atomic force microscopy. Nudged elastic band calculations with DFT will be performed to understand the chalcogen diffusion process, which will provide insights into the interfaces between different phases of TMCs and TMDs. The fourth task aims at quantifying the stability and dynamics of H-TMD/Cs by in-situ TEM and Raman studies under heating, strain, and electrical biasing. Phonon calculations using DFT will provide a basis for interpreting Raman spectra. This coherent framework involving synthesis, characterization, and computation will result in a broad scientific impact for energy related applications. The ability to develop new H-TMD/Cs will enhance a range of applications that include batteries, catalysts, switches, sensors, quantum computing components and smart coatings.

2-Dimensional Materials↗

Absorber Clamp for Microcalorimeter Decay Energy Spectrometry

Microcalorimeter Decay Energy Spectrometry (DES) is of interest to nuclear safeguards due to its ability to provide high precision isotopic compositions of nanogram-to microgram-scale samples of Pu and U and related daughter products. The DES method is able to record decay energy of each alpha-decay event in a sample that is embedded in a metal matrix (absorber) and thermally linked to a microcalorimeter detector. This work optimizes the DES technique used to thermally link the absorber and microcalorimeter detector element to allow for more rapid assembly and to increase detector performance and operating life. Optimized attachment methods are crucial for enhancing the viability of DES in high-sample-throughput facilities, such as those that support international nuclear safeguards measurements. Here, in this study, we designed and implemented a pressure-based absorber clamp and evaluated the performance of this new attachment method relative to pressed indium bond attachment. Results using the absorber clamp demonstrate a streamlined detector assembly procedure that minimizes accidental damage to detectors, as well as increasing detector pulse speeds by 57%. Spectral comparison shows the clamp preserves detector performance relative to indium attachment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Conversion of METL Diagnostic Flowmeters to Permanent Magnet Based Electromagnetic Flowmeters

The Mechanisms Engineering Test Loop (METL) uses three flowmeters to monitor sodium circulation through the main loop, the Cold Trap leg, and the Plugging Meter leg. When constructed, the Cold Trap flowmeter (CTFM) and Plugging Meter flowmeter (PMFM) were equipped with permanent magnets and Hall Sensors. By October of 2019, during normal operations, both the CTFM and PMFM failed, producing either erroneous or zero signals. Repairs to the flowmeters were attempted in January of 2020 but failed to resolve the issues. Therefore, starting in March of 2021, a plan was developed to convert the installed flowmeters to more robust permanent magnet based electromagnetic flowmeters (EMFMs). The Cold Trap EMFM (CT EMFM) and Plugging Meter EMFM (PM EMFM) were fully installed by August of 2021. Initial testing and commissioning were completed in November of 2021. Finally, the first calibration runs were finished in March of 2022. This report discusses the design, conversion, and calibration of the as-built CTFM and PMFM to robust permanent magnet based EMFMs. During the design phase, theoretical models were used to estimate the signal output and required magnet sizes. Then, the CTFM and PMFM were disassembled and converted to EMFMs. After commissioning, the CT EMFM and PM EMFM were calibrated using a ‘Time Transfer Procedure’ carried out with METL Expansion Vessels and Test Vessel Two. The accuracy of the calibration was estimated through an uncertainty analysis. Finally, the report describes some lessons learned for future flowmeter conversions and follow-up work. In total, both METL EMFM’s met the desired performance targets. Testing data showed that the METL EMFMs provide a output signal of roughly 2 mV at 1 GPM and 250 °C. During calibration, flowrates between 0.7 GPM and 2.4 GPM were achieved. In this flow range, calibration coefficients of 0.485 and 0.935 were measured as with errors ranging from 15-5% and 16-5% for the CT EMFM and PM EMFM, respectively. Above 1.5 GPM, the error was assumed to be about 5% for both METL EMFMs. Several points will be considered for future follow-up work on the METL EMFM’s. First, the signal noise issues in the PM EMFM will be addressed. It is likely the source of the noise is due to some stray EMF from a heater. Secondly, the NdFeB magnets will be replaced with a grade that has a Curie temperature above 80 °C. For example, a few grades of NeFeB magnets have Curie temperatures which exceed 150 °C and some SmCo magnets have Curie temperatures as high as 500 °C. Third, more calibration runs will be completed in the range of 0.5-2.5 GPM. This will further improve the accuracy of the calibration coefficient. Fourth, calibration runs will be completed up to 5 GPM. This requires a larger pressure relief valve to be installed on the Expansion Vessel and Test Vessel 2, as well as a revised calibration procedure. Lastly, calibration runs will be completed to account for cold spots in the system, which reduced the inlet temperature of the METL EMFMs. Overall, these points will improve the calibration coefficients derived in this work and also improve the performance of the METL EMFMs.

42 ENGINEERING↗

Convergent Manufacturing of Large-Scale Components for Nuclear Applications, via Additive Manufacturing and Powder Metallurgy Hot Isostatic Pressing

Powder metallurgy (PM)–hot isostatic pressing (PM-HIP) has long been recognized as a powerful route for producing fully dense, near net shape metallic components. By consolidating powders under high temperature and pressure, HIP provides isotropic properties, uniform microstructures, and scalability to complex geometries that are vital for sectors such as aerospace, energy, and nuclear power. Yet despite these advantages, the technology has remained constrained by costly trial and error canister fabrication, limitations of conventional forging, and incomplete knowledge about how the canister design influences final part properties. Additive manufacturing (AM), by contrast, thrives on design freedom and geometric flexibility but struggles with speed, scalability, and cost when applied to very large structures. The research presented in this report investigated how a convergent manufacturing approach, combining AM with PM-HIP, can merge the strengths of both technologies, leveraging AM’s flexibility for canister design and HIP’s consolidation capability to deliver reliable, large, and complex parts. The work progressed through three case studies that built on one another in scale and complexity. Small cylindrical canisters fabricated by conventional methods, laser powder bed fusion, and directed energy deposition were filled with stainless steel powders and subjected to HIP. The resulting parts demonstrated near-full density and mechanical properties on par with wrought stainless steel, showing for the first time that AM canisters can be a direct substitute for conventional ones without sacrificing quality. The next step involved a medium-scale, noncentrosymmetric T-valve, which is an enclosed, multibranch geometry that tested the limits of AM + PM-HIP integration. The T-valve achieved predictable shrinkage and uniform densification, confirming feasibility for enclosed designs. However, this study also revealed oxide inclusions and interfacial challenges at the AM + HIP boundary, underscoring the critical importance of controlling interface chemistry and employing robust, in situ strategies, such as melt pool monitoring and thermal monitoring, coupled with nondestructive evaluation techniques such as x-ray computed tomography. Finally, the effort culminated in fabricating a large-scale impeller weighing nearly 2000 lb and spanning 5 ft in diameter. Produced via multirobot wire arc AM and hot isostatic pressed to near-full density, the impeller validated industrial-scale feasibility. Predictive models closely matched experimental shrinkage, tensile properties were spatially uniform across the component, and the AM + PM-HIP interface proved mechanically sound despite the presence of oxide-decorated prior particle boundaries. This large-scale demonstration is a major milestone, showing that hybrid AM + PM‑HIP can reliably deliver components at reactor-relevant scales. Collectively, these studies charted a logical pathway: small-scale work built scientific confidence, medium-scale work highlighted opportunities and challenges, and large-scale work proved industrial impact. The overarching conclusion of this report is that AM + PM-HIP should not be seen as a replacement for forging but as a complementary pathway that provides the US with flexibility, resilience, and new options for manufacturing nuclear-grade components. Looking ahead, several directions emerge as critical to sustaining progress. Predictive modeling must become faster, more accessible, and more accurate, with digital twins and machine learning reducing reliance on trial and error. Powders and alloys must be optimized for HIP, with improved cleanliness, reduced oxides, and tailored chemistries that enhance creep, fatigue, and irradiation resistance. Interfaces between AM and HIP regions must be better engineered through coatings, machining strategies, and surface treatments to mitigate oxide formation and ensure reliable bonding to explore opportunities for HIP of targeted compositional parts, as well as multimaterial HIP cladding applications. Monitoring and nondestructive evaluation need to expand, incorporating multimodal sensors, x-ray computed tomography, and real-time data integration through platforms such as Pelican. At the same time, the pathway to industrial adoption requires techno-economic analysis, machinability studies, and qualification frameworks aligned with industry and regulatory standards. Finally, workforce and academic engagement must be strengthened. Programs that train technicians and engineers for US Navy and US Department of Energy manufacturing challenges should be paired with academic partnerships to support fundamental research, with open sharing of non-export-controlled data to accelerate innovation and build the next generation of experts. In conclusion, this report demonstrates that hybrid AM + PM-HIP is scientifically viable and strategically important. By combining the design agility of AM with the consolidation strength of HIP and embedding modeling, monitoring, and workforce development, this approach provided a transformative new capability for US manufacturing. The path forward is clear: hybrid AM + PM-HIP is not just a promising research direction but is also potentially an industrially relevant pathway that can reshape how nuclear-grade components are designed, qualified, and deployed.

36 MATERIALS SCIENCE↗

The novel Mechanical Ventilator Milano for the COVID-19 pandemic

This paper presents the Mechanical Ventilator Milano (MVM), a novel intensive therapy mechanical ventilator designed for rapid, large-scale, low-cost production for the COVID-19 pandemic. Free of moving mechanical parts and requiring only a source of compressed oxygen and medical air to operate, the MVM is designed to support the long-term invasive ventilation often required for COVID-19 patients and operates in pressure-regulated ventilation modes, which minimize the risk of furthering lung trauma. The MVM was extensively tested against ISO standards in the laboratory using a breathing simulator, with good agreement between input and measured breathing parameters and performing correctly in response to fault conditions and stability tests. The MVM has obtained Emergency Use Authorization by U.S. Food and Drug Administration (FDA) for use in healthcare settings during the COVID-19 pandemic and Health Canada Medical Device Authorization for Importation or Sale, under Interim Order for Use in Relation to COVID-19. Furthermore, following these certifications, mass production is ongoing and distribution is under way in several countries. The MVM was designed, tested, prepared for certification, and mass produced in the space of a few months by a unique collaboration of respiratory healthcare professionals and experimental physicists, working with industrial partners, and is an excellent ventilator candidate for this pandemic anywhere in the world

60 APPLIED LIFE SCIENCES↗