Search NASA⌕ Search

SEARCH · Search NASA

Results for “probing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

Off-harmonic optical probing of high intensity laser plasma expansion dynamics in solid density hydrogen jets

Due to the non-linear nature of relativistic laser induced plasma processes, the development of laser-plasma accelerators requires precise numerical modeling. Especially high intensity laser-solid interactions are sensitive to the temporal laser rising edge and the predictive capability of simulations suffers from incomplete information on the plasma state at the onset of the relativistic interaction. Experimental diagnostics utilizing ultra-fast optical backlighters can help to ease this challenge by providing temporally resolved inside into the plasma density evolution. We present the successful implementation of an off-harmonic optical probe laser setup to investigate the interaction of a high-intensity laser at 5.4 x 10 21 W/cm 2 peak intensity with a solid-density cylindrical cryogenic hydrogen jet target of 5μm diameter as a target test bed. The temporal synchronization of pump and probe laser, spectral filtering and spectrally resolved data of the parasitic plasma self-emission are discussed. The probing technique mitigates detector saturation by self-emission and allowed to record a temporal scan of shadowgraphy data revealing details of the target ionization and expansion dynamics that were so far not accessible for the given laser intensity. Plasma expansion speeds of up to (2.3 ± 0.4)x 10 7 m/s followed by full target transparency at 1.4ps after the high intensity laser peak are observed. A three dimensional particle-in-cell simulation initiated with the diagnosed target pre-expansion at -0.2ps and post processed by ray tracing simulations supports the experimental observations and demonstrates the capability of time resolved optical diagnostics to provide quantitative input and feedback to the numerical treatment within the time frame of the relativistic laser-plasma interaction.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Time-resolved luminescence detection of peroxynitrite using a reactivity-based lanthanide probe

Peroxynitrite (ONOO - ) is a powerful and short-lived oxidant formed in vivo, which can react with most biomolecules directly. To fully understand the roles of ONOO - in cell biology, improved methods for the selective detection and real-time analysis of ONOO - are needed. We present a water-soluble, luminescent europium(III) probe for the rapid and sensitive detection of peroxynitrite in human serum, living cells and biological matrices. We have utilised the long luminescence lifetime of the probe to measure ONOO - in a time-resolved manner, effectively avoiding the influence of autofluorescence in biological samples. To demonstrate the utility of the Eu(III) probe, we monitored the production of ONOO - in different cell lines, following treatment with a cold atmospheric plasma device commonly used in the clinic for skin wound treatment.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Are you using the right probe molecules for assessing the textural properties of metal–organic frameworks?

Textural properties—such as the surface area, pore size distribution, and pore volume—are at the forefront of characterization for porous materials. Therefore, it is essential to accurately and reproducibly report a material's textural properties as they could ultimately dictate its applicability. This work aims to provide insightful and comprehensive studies of textural properties for a set of metal–organic frameworks (MOFs), a class of porous materials, using various gases to equip researchers in the field with a helpful guide and reference. Here, we selected a series of nine MOFs with different surface areas, pore sizes, shapes, and chemical environments to represent a wide range of materials. We probed the textural properties of these MOFs using traditional and distinctive gases: N 2 , Kr and O 2 at 77 K, Ar at 87 K, and CO 2 at 195 and 273 K. With regard to surface area, we discuss the validity and challenges associated with the current BET method, the importance of utilizing the Rouquerol et al. consistency criteria to ensure accuracy and reproducibility, and the recommended gas probes for certain materials. For pore size distribution, we discuss the efficacy of each probe for determining the pore sizes within a porous material relative to the calculated distribution from its crystal structure, the limitations of current computational kernels used to calculate pore size distributions, and the need for advanced kernels to envelope the diversity of porous materials. Finally, for pore volume, we discuss the use of the Gurvich rule to obtain the total pore volume in comparison with calculated values from crystal structures and its consistency as a metric for porous materials. Ultimately, we hope that this article will aid researchers in characterizing the textural properties of porous materials and encourage the development of new kernels capable of encompassing the complexity of MOFs and other porous materials.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Challenges and strategies for probing the composite interface of PEM electrolyzers and fuel cells using operando AP-XPS

Left: cross-section schematic of a membrane electrode assembly, the working electrode changing state with applied potential. Center: the operando cell design that enables snapshot data acquisition during trajectory movement. Right: resulting spectra. Understanding the surface chemistry of electrocatalyst systems under operando conditions is central to revealing the electrocatalytic cell's working mechanisms. Determination of these catalytic processes on a molecular scale and the involved components is fundamental to streamlining material design for energy conversion and storage applications. X-ray photoelectron spectroscopy (XPS) is an established technique used to study the chemical and electronic states of materials. While the surface sensitivity of XPS is typically high, use of tender X-ray energies and technical advancements have allowed for the direct probing of solid–vapor and solid–liquid interfaces. However, protocols and documentation of experimental considerations for operando XPS probing of working electrolyzers and fuel cells remain scarce. Herein, we report an approach for the study of working polymer electrolyte membrane (PEM) electrolysis cells using ambient pressure X-ray photoelectron spectroscopy (AP-XPS). This approach directly probes the composite electrode surface on the membrane electrode assembly (MEA) in 100% relative humidity to establish a meaningful liquid layer for electrocatalysis. We carry out a systematic investigation from the cell constituent components to a fully assembled working operando electrolytic system and establish a method for AP-XPS study of the complex composite MEA, providing recommendations for data acquisition and component analysis.

Hamlyn, Rebecca↗

Direct Measurement of ICRF-Enhanced Plasma Potentials on WEST Using Reciprocating Emissive Probes

An extensive documentation of ICRF-enhanced plasma potentials has been conducted over two experimental campaigns on the WEST tokamak using reciprocating emissive probes magnetically connected to two ICRF antennas. The collected data spans a wide range of antenna electrical settings (coupled power, toroidal phasing, left–right power balance) and plasma parameters (density at the antenna limiter above and below the lower hybrid resonance, plasma current, minority fraction). By scanning the edge safety factor across multiple probe plunges, the magnetic connection between the probe and the antenna varied, enabling the construction of a 2D map of the plasma and floating potentials around an active ICRF antenna. This dataset will be used to validate RF simulation tools equipped with the sheath boundary condition and used to predict RF rectified potentials and ICRF-induced impurity sputtering in future machines. This paper presents the diagnostic and some initial measurements, while the rest will be reported elsewhere.

Diab, Raymond [Massachusetts Inst. of Technology (↗

Basic factors for acquiring, correcting, and interpreting probe current-voltage characteristic in moderate-collisional plasma for determining electron energy distribution

Methods for inferring the electron distribution function (EDF) from a probe current–voltage trace are reviewed for moderate-collisional plasma. The explicit accounting of particle collisions, modeling sheath depletion, and electron refilling processes are rarely performed when analyzing probe measurements, yet they are critical for regime validity, EDF-profile accuracy, and space potential quantification precision. Furthermore, the advantages, limitations, and utilization of large-area wall probes in moderate-collisional plasma, capable of highly resolved indications of energetic electrons in plasma, are outlined.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Axial proton probing of magnetic and electric fields inside laser-driven coils

In a laser-driven coil, a laser is used to eject electrons from a plate, which then draws a current through a loop. Diagnosing the field strength, geometry, and conditions within these loops has been one of the primary difficulties in fielding this type of target. In this paper, the diagnostic technique of axial proton probing with a mesh fiducial of a laser-driven coil is demonstrated. Multiple coil types were driven by a 1 ns, 1.25 kJ long pulse beam and probed several times. Here, this technique provides significantly more information than transverse probing on electric- and magnetic-field strength in the region of interest and shows in our experiment complex, non-uniform current path structures and charge distribution.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Ultrafast vibrational dynamics of a trigonal planar anionic probe in ionic liquids (ILs): A two-dimensional infrared (2DIR) spectroscopic investigation

A major impediment limiting the widespread application of ionic liquids (ILs) is their high shear viscosity. Incorporation of a tricyanomethanide (TCM - ) anion in ILs leads to low shear viscosity and improvement of several characteristics suitable for large scale applications. However, properties including interactions of TCM - with the local environment and dynamics of TCM - have not been thoroughly investigated. Herein, we have studied the ultrafast dynamics of TCM - in several imidazolium ILs using linear IR and two-dimensional infrared spectroscopy techniques. The spectral diffusion dynamics of the CN stretching modes of TCM - in all ILs exhibit a nonexponential behavior with a short time component of ~2 ps and a long time component spanning ~9 ps to 14 ps. The TCM - vibrational probe reports a significantly faster relaxation of ILs compared to those observed previously using linear vibrational probes, such as thiocyanate and selenocyanate. Our results indicate a rapid relaxation of the local ion-cage structure embedding the vibrational probe in the ILs. The faster relaxation suggests that the lifetime of the local ion-cage structure decreases in the presence of TCM - in the ILs. Linear IR spectroscopic results show that the hydrogen-bonding interaction between TCM - and imidazolium cations in ILs is much weaker. Shorter ion-cage lifetimes together with weaker hydrogen-bonding interactions account for the low shear viscosity of TCM - based ILs compared to commonly used ILs. In addition, this work demonstrates that TCM - can be used as a potential vibrational reporter to study the structure and dynamics of ILs and other molecular systems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Excited state dynamics of cis , cis -1,3-cyclooctadiene: UV pump VUV probe time-resolved photoelectron spectroscopy

We present UV pump, vacuum ultraviolet probe time-resolved photoelectron spectroscopy measurements of the excited state dynamics of cis,cis-1,3-cyclooctadiene. A 4.75 eV deep UV pump pulse launches a vibrational wave packet on the first electronically excited state, and the ensuing dynamics are probed via ionization using a 7.92 eV probe pulse. The experimental results indicate that the wave packet undergoes rapid internal conversion to the ground state in under 100 fs. Comparing the measurements with electronic structure and trajectory surface hopping calculations, we are able to interpret the features in the measured photoelectron spectra in terms of ionization to several states of the molecular cation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

First application of a digital mirror Langmuir probe for real-time plasma diagnosis

We report for the first time, a digital Mirror Langmuir Probe (MLP) has successfully sampled plasma temperature, ion saturation current, and floating potential together on a single probe tip in real time in a radio-frequency driven helicon linear plasma device. This is accomplished by feedback control of the bias sweep to ensure a good fit to I–V characteristics with a high frequency, high power digital amplifier, and field-programmable gate array controller. Measurements taken by the MLP were validated by a low speed I–V characteristic manually collected during static plasma conditions. Plasma fluctuations, induced by varying the axial magnetic field($\widetilde{f}$ = 10 Hz), were also successfully monitored with the MLP. Further refinement of the digital MLP pushes it toward a turn-key system that minimizes the time to deployment and lessens the learning curve, positioning the digital MLP as a capable diagnostic for the study of low radio-frequency plasma physics. These demonstrations bolster confidence in fielding such digital MLP diagnostics in magnetic confinement experiments with high spatial and adequate temporal resolution, such as edge plasma, scrape-off layer, and divertor probes.

47 OTHER INSTRUMENTATION↗

Cryogenic probe for low-noise, high-frequency electronic measurements

The design and performance of a low-noise, modular cryogenic probe, which is applicable to a wide range of measurements over a broad range of working frequencies, temperatures, and magnetic fields, is presented. The design of the probe facilitates the exchange of sample holders and sample-stage amplifiers, which, combined with its characteristic low transmission and reflection loss, make this design suitable for high precision or low sensitivity measurements. The specific example of measuring the shot noise of magnetic tunnel junctions is discussed. We highlight various design characteristics chosen specifically to expand the applicability of the probe to measurement techniques such as nuclear magnetic resonance.

47 OTHER INSTRUMENTATION↗

Compact in situ probe for magnetotransport measurements of 2D materials under variable tensile strain

The recent development of freestanding oxide membranes has opened new opportunities for strain engineering of transition metal oxides beyond values accessible in bulk samples. While a number of studies have been performed with fixed strain, the ability to dynamically control the strain state during measurement would be greatly enabling. To this end, we present an in situ uniaxial strain probe optimized for transport measurements of tensile-strained 2D or quasi-2D materials down to 2 K. Utilizing a flexible polyimide substrate as the stress transfer medium, our platform simplifies the sample preparation process and allows precise alignment of strain fields relative to the crystalline axes. An in situ optical microscope monitors the macroscopic strain state operando and makes it possible to complete an entire magnetotransport study at cryogenic temperatures under continuous strain variations. We demonstrate the capabilities of the probe on a freestanding LaNiO 3 membrane, where we induce tensile strain up to 8% and observe a corresponding strong transport anisotropy. In view of the rapid developments in low-dimensional materials synthesis and the plethora of novel quantum phenomena they exhibit, this strain probe provides general instrumentation for examining and controlling these properties via strain.

2D materials↗

Probing autoionization decay lifetimes of the 4d−16ℓ core-excited states in xenon using attosecond noncollinear four-wave-mixing spectroscopy

The decay of core-excited states is a sensitive probe of autoionization dynamics and correlation effects in many-electron systems, occurring on ultrafast timescales. Xenon, with its dense manifold of autoionizing resonances that can be coupled with near-infrared light, provides a platform to investigate these processes. In this work, the autoionization decay lifetimes of 4d-16ℓ (ℓ = s, p, d, …) core-excited states in xenon atoms are probed with extreme ultraviolet (XUV) attosecond noncollinear four-wave-mixing (FWM) spectroscopy. The 4d{5/2,3/2}-16p XUV-bright states (optically dipole-allowed) exhibit decay lifetimes of ∼6 fs, which is consistent with spectator-type decay. In contrast, the 4d{5/2,3/2}-16s and 4d{5/2,3/2}-16d XUV-dark states (optically dipole forbidden) show longer decay lifetimes of ∼20 fs. Photoionization calculations confirm that all core-hole states with 4d character should decay via spectator channels in ≤6 fs, suggesting that the apparently longer dark-state decay times arise from an alternative mechanism. A few-level simulation of the FWM process shows that the inclusion of a nearby, longer-lived dark state can mimic the experimental FWM signal, suggesting population cycling with a second electronic state with non-4d character. Ab initio calculations support the presence of such multielectron excited states in the 60-70 eV range. These results demonstrate that FWM signals can encode coupled-state dynamics when probing complex systems, highlighting the importance of combining theoretical and experimental approaches to disentangle accurate core-level decay pathways and lifetimes.

Puskar, Nicolette G↗

Automated scanning probe microscopy of combinatorial ferroelectric libraries: Gaussian-process-guided exploration and noise-aware experiment planning

Combinatorial materials libraries provide an efficient route for mapping composition–property relationships, but their broader impact depends on rapid, quantitative, and functionally relevant characterization. Scanning Probe Microscopy (SPM), including piezoresponse force microscopy (PFM), offers significant potential for quantitative, functionally relevant combi-library readouts. Here, we implement a fully automated SPM workflow for ferroelectric combinatorial libraries and benchmark Gaussian-process-based Bayesian optimization strategies for autonomous experiment planning. The workflow integrates automated probe motion, contact optimization, imaging, and dual amplitude resonance tracking-PFM spectroscopy, and uses scalarized spectroscopic observables to guide subsequent measurements. Stage motion, probe engagement, in-contact tuning, imaging, spectroscopy, and the choice of the next measurement location all proceed without human input. We demonstrate the approach on Sm-doped BiFeO 3 and Zn x Mg 1−x O libraries. By comparing vanilla Bayesian optimization with a measured-noise variant, we show that explicit treatment of local reproducibility can improve modeling of composition-dependent response when the measured variance is physically meaningful, but can also reduce robustness when variability is dominated by outliers or topographic artifacts. Furthermore, these results establish automated SPM as a bridge between combinatorial synthesis and quantitative functional characterization.

Liu, Yu [University of Tennessee, Knoxville, TN (U↗

Protocols for x-ray transient grating pump/optical probe experiments at x-ray free electron lasers

Abstract Transient grating spectroscopy is a specialized application of the four-wave-mixing methodology and constitutes a versatile technique for investigating the dynamics of vibrational, magnetic and electronic degrees of freedom of matter in a background-free fashion. Recent developments in free-electron laser sources have enabled the extension of this technique into the extreme ultraviolet range. Ongoing efforts to expand transient grating spectroscopy into the x-ray regime promise numerous advantages: (1) substantial penetration depths that allow for probing bulk material properties, (2) element specificity via specific core-excited states, and (3) short wavelengths that allow for excitation gratings with higher momentum transfer and improved spatial resolution. In this study, we comprehensively outline the procedures for conducting x-ray transient grating pump/optical probe experiment. The process encompasses the design and alignment of the experimental setup, as well as the subsequent steps involved in data acquisition and analysis. This paper is intended as a comprehensive guide for researchers interested in implementing x-ray transient grating spectroscopy, providing valuable insights into the intricacies of the experimental workflow required for this novel technique. Furthermore, we discuss the potential for extending this methodology to an x-ray pump/x-ray probe scheme, envisioning a future direction that holds promise for enhancing the capabilities and scope of x-ray transient grating spectroscopy, opening new opportunities for studying ultrafast processes with unprecedented temporal and spatial resolutions.

Optics↗

Widen the resonance at ultra-high energies: novel probes of neutrino self-interactions in the high-mass regime

Neutrino self-interactions beyond the Standard Model are well motivated by the nonzero masses of neutrinos, which are the only known particles guaranteed to have new physics. Meanwhile, cosmic messengers, especially neutrinos, play a central role in probing new physics, as they provide experimental conditions far beyond the reach of laboratories and serve as the link between laboratory fundamental-physics discoveries and their roles in the Universe, where many new physics motivations originate.In this work, we propose a novel probe of neutrino self-interactions through ultrahigh-energy neutrinos scattering off the cosmic neutrino background when the lightest neutrino species remains relativistic today.This allows us to “Widen the Resonance” of such scattering [1].In addition, we also provide a semi-analytic framework for cosmogenic ultrahigh-energy neutrino production, avoiding computationally intensive simulations and yielding results precise enough for beyond-the-standard-model studies.The widened resonance enables future ultrahigh-energy neutrino telescopes,in particular GRAND, to probe mediator masses from MeV to GeV, reaching couplings down to g ∼ 10$^{-3}$ — up to two orders of magnitude beyond current bounds.Our results enhance the discovery potential of neutrino self-interactions in the high-mass regime, potentially offering crucial insights into the connections between the neutrino sector and dark sector.

Machado, Pedro A.N. [Fermilab] (ORCID:000000029118↗

Robust, versatile DNA FISH probes for chromosome-specific repeats in Caenorhabditis elegans and Pristionchus pacificus

Repetitive DNA sequences are useful targets for chromosomal fluorescence in situ hybridization. We analyzed recent genome assemblies of Caenorhabditis elegans and Pristionchus pacificus to identify tandem repeats with a unique genomic localization. Based on these findings, we designed and validated sets of oligonucleotide probes for each species targeting at least 1 locus per chromosome. These probes yielded reliable fluorescent signals in different tissues and can easily be combined with the immunolocalization of cellular proteins. Synthesis and labeling of these probes are highly cost-effective and require no hands-on labor. The methods presented here can be easily applied in other model and nonmodel organisms with a sequenced genome.

59 BASIC BIOLOGICAL SCIENCES↗

Mixed Element Microparticle Characterization by Electron Probe Microanalysis

Abstract Microparticle compositional characterization for nuclear forensics has traditionally been achieved by “gold-standard” destructive analytical techniques such as large geometry-secondary ion mass spectrometry and fission track-thermal ionization mass spectrometry, but long processing times and total sample consumption eliminate the option of subsequent analysis by other methods. Electron probe microanalysis has long been widely employed for rapid, nondestructive, micrometer-scale compositional measurements and imaging in fields such as material science and geology and may therefore need to be reevaluated as an alternative tool for microparticle analysis for the nuclear forensics community. This study presents the use of electron probe microanalysis for imaging and quantitative characterization of homogeneous microparticles utilizing a calibration curve based on high-precision quadrupole-inductively coupled plasma-mass spectrometry analyses. Samples of opportunity synthesized at Savannah River National Laboratory, nickel-doped cerium oxide microparticles, were selected as analogs for plutonium-doped uranium oxide microparticles. Positive detection and accurate quantification of variable amounts of nickel dopant down to trace levels (10s of parts per million) suggest applicability of this technique to other mixed element systems (e.g., actinides). Quantitative single-particle characterization via electron probe microanalyzer may thus provide a high fidelity, nondestructive complement to techniques currently in use.

Riche, Alexis T. (ORCID:0009000121978126)↗