Monitoring Well Installation Completion Report for Ransom Road Landfill, Vertical Processing Facility, and Environmental Health Facility, Solid Waste Management Units: 003, 077, and 079

The intended purpose of the Monitoring Well Installation project is to support the Kennedy Space Center (KSC) Environmental Remediation Department’s Resource Conservation and Recovery Act Program by installing new monitoring wells. The wells are installed in accordance with the Brevard County Health Department and St. Johns River Water Management Districts rules and guidelines.

Well Installation↗

Space station microscopy: Beyond the box

Microscopy aboard Space Station Freedom poses many unique challenges for in-flight investigations. Disciplines such as material processing, plant and animal research, human reseach, enviromental monitoring, health care, and biological processing have diverse microscope requirements. The typical microscope not only does not meet the comprehensive needs of these varied users, but also tends to require excessive crew time. To assess user requirements, a comprehensive survey was conducted among investigators with experiments requiring microscopy. The survey examined requirements such as light sources, objectives, stages, focusing systems, eye pieces, video accessories, etc. The results of this survey and the application of an Intelligent Microscope Imaging System (IMIS) may address these demands for efficient microscopy service in space. The proposed IMIS can accommodate multiple users with varied requirements, operate in several modes, reduce crew time needed for experiments, and take maximum advantage of the restrictive data/ instruction transmission environment on Freedom.

Hunter, N. R.↗

Protein crystal growth in microgravity

Major advances have been made in several of the experimental aspects of protein crystallography, leaving protein crystallization as one of the few remaining bottlenecks. As a result, it has become important that the science of protein crystal growth is better understood and that improved methods for protein crystallization are developed. Preliminary experiments with both small molecules and proteins indicate that microgravity may beneficially affect crystal growth. For this reason, a series of protein crystal growth experiments using the Space Shuttle was initiated. The preliminary space experiments were used to evolve prototype hardware that will form the basis for a more advanced system that can be used to evaluate effects of gravity on protein crystal growth. Various optical techniques are being utilized to monitor the crystal growth process from the incipient or nucleation stage and throughout the growth phase. The eventual goal of these studies is to develop a system which utilizes optical monitoring for dynamic control of the crystallization process.

Rosenblum, William M.↗

Efficient Signal Processing in BOTDA: Utilizing PCA and PCA-Based Neural Networks for Temperature Monitoring

This work presents a comparative analysis of the various signal processing techniques used in the Brillouin gain spectrum (BGS) peak estimation. Traditional fitting methods such as Lorentzian curve fitting (LCF) are slow and less effective in noisy data. PCA-based methods were tested on the experimental data: A Euclidian distance-based approach, and a probabilistic deep neural network (PDNN) based approach, both using 5 principal components to represent a single BGS. Both methods significantly reduce computational time with respect to LCF, whereas PDNN offers uncertainty insights along with the parameter value. Measuring a range of temperatures, analyzing accuracy, and speed, it can be concluded that PCA trained PDNN outperforms other methods, and appears to be helpful in scenario where large datasets are generated.

Brillouin optical time domain analysis↗

Designing an autonomous environment for mission critical operation of the EUVE satellite

Since the launch of NASA's Extreme Ultraviolet Explorer (EUVE) satellite in 1992, there has only been a handful of occurrences that have warranted manual intervention in the EUVE Science Operations Center (ESOC). So, in an effort to reduce costs, the current environment is being redesigned to utilize a combination of off-the-shelf packages and recently developed artificial intelligence (AI) software to automate the monitoring of the science payload and ground systems. The successful implementation of systemic automation would allow the ESOC to evolve from a seven day/week, three shift operation, to a seven day/week one shift operation. First, it was necessary to identify all areas considered mission critical. These were defined as follows: (1) The telemetry stream must be monitored autonomously and anomalies identified. (2) Duty personnel must be automatically paged and informed of the occurrence of an anomaly. (3) The 'basic' state of the ground system must be assessed. (4) Monitors should check that the systems and processes needed to continue in a 'healthy' operational mode are working at all times. (5) Network loads should be monitored to ensure that they stay within established limits. (6) Connectivity to Goddard Space Flight Center (GSFC) systems should be monitored as well, not just for connectivity of the network itself but also for the ability to transfer files. (7) All necessary peripheral devices should be monitored. This would include the disks, routers, tape drives, printers, tape carousel, and power supplies. (8) System daemons such as the archival daemon, the Sybase server, the payload monitoring software, and any other necessary processes should be monitored to ensure that they are operational. (9) The monitoring system needs to be redundant so that the failure of a single machine will not paralyze the monitors. (10) Notification should be done by means of looking though a table of the pager numbers for current 'on call' personnel. The software should be capable of dialing out to notify, sending email, and producing error logs. (11) The system should have knowledge of when real-time passes and tape recorder dumps will occur and should know that these passes and data transmissions are successful. Once the design criteria were established, the design team split into two groups: one that addressed the tracking, commanding, and health and safety of the science payload and another group that addressed the ground systems and communications aspects of the overall system.

Abedini, Annadiana↗

Motorized Beam Alignment of a Commercial X-ray Diffractometer

X-ray diffraction (XRD) is a powerful analysis method that allows researchers to noninvasively probe the crystalline structure of a material. This includes the ability to determine the crystalline phases present, quantify surface residual stresses, and measure the distribution of crystallographic orientations. The Structures and Materials Division at the NASA Glenn Research Center (GRC) heavily uses the on-site XRD lab to characterize advanced metal alloys, ceramics, and polymers. One of the x-ray diffractometers in the XRD lab (Bruker D8 Discover) uses three different x-ray tubes (Cu, Cr, and Mn) for optimal performance over numerous material types and various experimental techniques. This requires that the tubes be switched out and aligned between experiments. This alignment maximizes the x-ray tube s output through an iterative process involving four set screws. However, the output of the x-ray tube cannot be monitored during the adjustment process due to standard radiation safety engineering controls that prevent exposure to the x-ray beam when the diffractometer doors are open. Therefore, the adjustment process is a very tedious series of blind adjustments, each followed by measurement of the output beam using a PIN diode after the enclosure doors are shut. This process can take up to 4 hr to perform. This technical memorandum documents an in-house project to motorize this alignment process. Unlike a human, motors are not harmed by x-ray radiation of the energy range used in this instrument. Therefore, using motors to adjust the set screws will allow the researcher to monitor the x-ray tube s output while making interactive adjustments from outside the diffractometer. The motorized alignment system consists of four motors, a motor controller, and a hand-held user interface module. Our goal was to reduce the alignment time to less than 30 min. The time available was the 10-week span of the Lewis' Educational and Research Collaborative Internship Project (LERCIP) summer internship program and the budget goal was $1200. In this report, we will describe our motorization design and discuss the results of its implementation.

Van Zandt, Noah R.↗

Mass Spectrometer Containing Multiple Fixed Collectors

A miniature mass spectrometer that incorporates features not typically found in prior mass spectrometers is undergoing development. This mass spectrometer is designed to simultaneously measure the relative concentrations of five gases (H2, He, N2, O2, and Ar) in air, over the relative-concentration range from 10(exp -6) to 1, during a sampling time as short as 1 second. It is intended to serve as a prototype of a product line of easy-to-use, portable, lightweight, highspeed, relatively inexpensive instruments for measuring concentrations of multiple chemical species in such diverse applications as detecting explosive or toxic chemicals in air, monitoring and controlling industrial processes, measuring concentrations of deliberately introduced isotopes in medical and biological investigations, and general environmental monitoring. The heart of this mass spectrometer is an integral combination of a circular cycloidal mass analyzer, multiple fixed ion collectors, and two mass-selective ion sources. By circular cycloidal mass analyzer is meant an analyzer that includes (1) two concentric circular cylindrical electrodes for applying a radial electric field and (2) a magnet arranged to impose a magnetic flux aligned predominantly along the cylindrical axis, so that ions, once accelerated into the annulus between the electrodes, move along circular cycloidal trajectories. As in other mass analyzers, trajectory of each ion is determined by its mass-to-charge ratio, and so ions of different species can be collected simultaneously by collectors (Faraday cups) at different locations intersected by the corresponding trajectories (see figure). Unlike in other mass analyzers, the installation of additional collectors to detect additional species does not necessitate increasing the overall size of the analyzer assembly.

Moskala, Robert↗

Autoregressive distributed lag-based dynamic uniformity modeling and monitoring approaches for superconductor manufacturing

High-temperature superconductors (HTS), known for their high efficiency and low energy loss, have found profound applications across various fields, driving the demand for long, uniformly performing tapes. However, ensuring uniform performance over extended lengths of HTS tapes, often characterized by the consistency of critical current, remains challenging due to fluctuations in growth conditions during manufacturing. Here, to elucidate the mechanisms underlying variations in tape uniformity and enable real-time monitoring of associated parameters, we propose an Autoregressive Distributed Lag (ADL)-based Dynamic Uniformity Modeling and Monitoring (ADUM2) approach. This method integrates uniformity measurement, the identification of critical process parameters and real-time monitoring within the manufacturing process. The ADUM2 approach is applied to the advanced metal organic chemical vapor deposition (A-MOCVD) process, a pilot-scale method for superconductor manufacturing. Our model demonstrates superior performance compared to benchmark methods, accounting for over 80% of the total variance in the data and identifying 13 key process parameters influencing the uniformity of HTS tapes. This study offers significant insights into the high-temperature superconductor manufacturing process and holds the potential to facilitate the production of cost-effective, uniformly performing long superconducting tapes in the future.

autoregressive distributed lag analysis↗

Embedded Sensing in Additive Manufacturing Metal and Polymer Parts: A Comparative Study of Integration Techniques and Structural Health Monitoring Performance

This study presents a comparative evaluation of post-process sensor integration in additively manufactured (AM) metal and the in-situ process for polymer structures for structural health monitoring (SHM), with an emphasis on embedded sensors. Geometrically identical specimens were fabricated using copper via metal fused filament fabrication (FFF) and PLA via polymer FFF, with piezoelectric transducers (PZTs) inserted into internal cavities to assess the influence of material and placement on sensing fidelity. Mechanical testing under compressive and point loads generated signals that were transformed into time–frequency spectrograms using a Short-Time Fourier Transform (STFT) framework. An engineered RGB representation was developed, combining global amplitude scaling with an amplitude-envelope encoding to enhance contrast and highlight subtle wave features. These spectrograms served as inputs to convolutional neural networks (CNNs) for classification of load conditions and detection of damage-related features. Results showed reliable recognition in both copper and PLA specimens, with CNN classification accuracies exceeding 95%. Embedded PZTs were especially effective in PLA, where signal damping and environmental sensitivity often hinder surface-mounted sensors. This work demonstrates the advantages of embedded sensing in AM structures, particularly when paired with spectrogram-based feature engineering and CNN modeling, advancing real-time SHM for aerospace, energy, and defense applications.

additive manufacturing↗

Application of Advanced Materials Processing to Enable Direct Production of Fast Reactor Fuel Alloys

Argonne National Laboratory (the Contractor), located in Lemont, IL, and Oklo, Inc. (the Participant), headquartered in Sunnyvale, CA, entered into a Cooperative Research and Development Agreement (CRADA) to integrate advanced electrorefining co-deposition and molten-salt monitoring technologies to produce a uranium-transuranic (U/TRU) alloy within a controlled composition range that can be used as fast reactor fuel for Oklo, Inc.’s advanced reactor technology. Argonne performed the integration of electrorefining and process monitoring technologies, determined operating parameters for producing U/TRU alloys, and developed optimized design and operating parameters for co-deposition of U/TRU alloys. Oklo, Inc. worked with Argonne and the Nuclear Regulatory Commission (NRC) to provide the necessary process documentation to begin implementing pyroprocessing technology in the fast reactor fuel production process. Outcomes of this project included a pilot-scale co-deposition cathode design and technical basis for the operation of the co-deposition electrorefiner to produce U/TRU alloys with controlled composition.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Application of digital image processing techniques and information systems to water quality monitoring of Lake Tahoe

The Tahoe basin occupies over 500 square miles of territory located in a graben straddling the boundary between California and Nevada. Lake Tahoe contains 126 million acre-feet of water. Since the 1950's the basin has experienced an ever increasing demand for land development at the expense of the natural watershed. Discharge of sediment to the lake has greatly increased owing to accelerated human interference, and alterations to the natural drainage patterns are evident in some areas. In connection with an investigation of the utility of a comprehensive system that takes into account the causes as well as the effects of lake eutrophication, it has been attempted to construct an integrated and workable data base, comprised of currently available data sources for the Lake Tahoe region. Attention is given to the image based information system (IBIS), the construction of the Lake Tahoe basin data base, and the application of the IBIS concept to the Lake Tahoe basin.

Smith, A. Y.↗

Design and qualification of the SEU/TD Radiation Monitor chip

This report describes the design, fabrication, and testing of the Single-Event Upset/Total Dose (SEU/TD) Radiation Monitor chip. The Radiation Monitor is scheduled to fly on the Mid-Course Space Experiment Satellite (MSX). The Radiation Monitor chip consists of a custom-designed 4-bit SRAM for heavy ion detection and three MOSFET's for monitoring total dose. In addition the Radiation Monitor chip was tested along with three diagnostic chips: the processor monitor and the reliability and fault chips. These chips revealed the quality of the CMOS fabrication process. The SEU/TD Radiation Monitor chip had an initial functional yield of 94.6 percent. Forty-three (43) SEU SRAM's and 14 Total Dose MOSFET's passed the hermeticity and final electrical tests and were delivered to LL.

Buehler, Martin G.↗

Advanced monitoring concepts

The emphasis in initial work will be on application of image processing techniques in the site monitoring of an ILS glide slope transmitting array. The glide slope requires a clear area in front of the antennas for use as a reflecting zone. Reflecting or scattering obstacles in this area can cause incorrect path formation and system outages. Direct video monitoring is impractical due to the narrow band nature of communication links from the ILS site to the regional maintenance location. Slow scan video is possible, but even this technique may require transmission of large amounts of data, tying up remote monitoring lines. The steps used to minimize data transmission are listed.

Lilley, Robert W.↗

Neural network based expert system for compressor stall monitoring

This research is designed to apply a new information processing technology, artificial neural networks, to monitoring compressor stall. The outputs of neural networks support the dynamic knowledge data base of an expert system. This is the open-loop mode to avoid compressor stall. The integration of a control system with neural networks is the closed-loop mode in stall avoidance. The feasibility of the concept has been demonstrated for the compressor of 16-foot transonic/supersonic propulsion wind tunnels. The construction of a prototpye expert system has been initiated.

Lo, Ching F.↗

Applying Standard Interfaces to a Process-Control Language

A method of applying open-operating-system standard interfaces to the NASA User Interface Language (UIL) has been devised. UIL is a computing language that can be used in monitoring and controlling automated processes: for example, the Timeliner computer program, written in UIL, is a general-purpose software system for monitoring and controlling sequences of automated tasks in a target system. In providing the major elements of connectivity between UIL and the target system, the present method offers advantages over the prior method. Most notably, unlike in the prior method, the software description of the target system can be made independent of the applicable compiler software and need not be linked to the applicable executable compiler image. Also unlike in the prior method, it is not necessary to recompile the source code and relink the source code to a new executable compiler image. Abstraction of the description of the target system to a data file can be defined easily, with intuitive syntax, and knowledge of the source-code language is not needed for the definition.

Berthold, Richard T.↗

An OSEE Based Portable Surface Contamination Monitor

Many industrial and aerospace processes involving the joining of materials, require sufficient surface cleanliness to insure proper bonding. Processes as diverse as painting, welding, or the soldering of electronic circuits will be compromised if prior inspection and removal of surface contaminants is inadequate. As process requirements become more stringent and the number of different materials and identified contaminants increases, various instruments and techniques have been developed for improved inspection. One such technique based on the principle of Optically Stimulated Electron Emission (OSEE) has been explored for a number of years as a tool for surface contamination monitoring. Some of the benefits of OSEE are: it's non-contacting; requires little operator training; and has very high contamination sensitivity. This paper describes the development of a portable OSEE based surface contamination monitor. The instrument is suitable for both hand-held and robotic inspections with either manual or automated control of instrument operation. In addition, instrument output data is visually displayed to the operator and may be output to an external computer for archiving or analysis.

Perey, Daniel F.↗