Search NASA⌕ Search

SEARCH · Search NASA

Results for “quantitative microscopy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

Analysis of structure and phase composition of rails subjected to differential hardening at different regimes

Differential hardening of rails by compressed air in different regimes is accompanied by formation of morphologically different structure, being formed according to the diffusion mechanism of γ↔α transformation and consisting of grains of lamellar pearlite, free ferrite and grains of ferrite-carbide mixture. By methods of transmission electron microscopy the layer by layer analysis of differentially hardened rails has been carried out, the quantitative parameters of the structure, phase composition and dislocation substructure have been established and their comparison has been made for different regimes of hardening. It has been found that the structure-phase states being formed have gradient character, defined by the hardening regime, direction of study from the surface of rolling and by depth of location of layer under study.

36 MATERIALS SCIENCE↗

A novel assay to measure low-density lipoproteins binding to proteoglycans

Background: The binding of low-density lipoprotein (LDL) to proteoglycans (PGs) in the extracellular matrix (ECM) of the arterial intima is a key initial step in the development of atherosclerosis. Although many techniques have been developed to assess this binding, most of the methods are labor-intensive and technically challenging to standardize across research laboratories. Thus, sensitive, and reproducible assay to detect LDL binding to PGs is needed to screen clinical populations for atherosclerosis risk. Objectives: The aim of this study was to develop a quantitative, and reproducible assay to evaluate the affinity of LDL towards PGs and to replicate previously published results on LDL-PG binding. Methods: Immunofluorescence microscopy was performed to visualize the binding of LDL to PGs using mouse vascular smooth muscle (MOVAS) cells. An in-cell ELISA (ICE) was also developed and optimized to quantitatively measure LDL-PG binding using fixed MOVAS cells cultured in a 96-well format. Results: We used the ICE assay to show that, despite equal APOB concentrations, LDL isolated from adults with cardiovascular disease bound to PG to a greater extent than LDL isolated from adults without cardiovascular disease (p<0.05). Conclusion: We have developed an LDL-PG binding assay that is capable of detecting differences in PG binding affinities despite equal APOB concentrations. Future work will focus on candidate apolipoproteins that enhance or diminish this interaction.

59 BASIC BIOLOGICAL SCIENCES↗

Direct probing of electron and hole trapping into nano-floating-gate in organic field-effect transistor nonvolatile memories

Electron and hole trapping into the nano-floating-gate of a pentacene-based organic field-effect transistor nonvolatile memory is directly probed by Kelvin probe force microscopy. The probing is straightforward and non-destructive. The measured surface potential change can quantitatively profile the charge trapping, and the surface characterization results are in good accord with the corresponding device behavior. Both electrons and holes can be trapped into the nano-floating-gate, with a preference of electron trapping than hole trapping. The trapped charge quantity has an approximately linear relation with the programming/erasing gate bias, indicating that the charge trapping in the device is a field-controlled process.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Microscopy modality transfer of steel microstructures: Inferring scanning electron micrographs from optical microscopy using generative AI

Scanning electron microscopy (SEM) is resource intensive, which limits its throughput in some applications. As an alternative, we propose applying computer vision and machine learning to generate high-quality synthetic SEM micrographs from micrographs obtained using light optical microscopy (LOM). Working with a correlated LOM/SEM dataset of dual-phase steel images, we test generative models of various architectures, including encoder-decoder networks, generative adversarial networks (GANs), and diffusion-based models. We find that the diffusion models significantly outperform other methods on both qualitative and quantitative assessments, while preserving key metallurgical meaning. This work establishes diffusion as the state-of-the-art for microscopy modality transfer and demonstrates the potential of AI-powered microscopy to enhance LOM with micron scale structural recreation.

Computer vision↗

Characterizing nanoscale scanning probes using electron microscopy: A novel fixture and a practical guide

The nanoscale geometry of probe tips used for atomic force microscopy (AFM) measurements determines the lateral resolution, contributes to the strength of the tip-surface interaction, and can be a significant source of uncertainty in the quantitative analysis of results. While inverse imaging of the probe tip has been used successfully to determine probe tip geometry, direct observation of the tip profile using electron microscopy (EM) confers several advantages: it provides direct (rather than indirect) imaging, requires fewer algorithmic parameters, and does not require bringing the tip into contact with a sample. In the past, EM-based observation of the probe tip has been achieved using ad hoc mounting methods that are constrained by low throughput, the risk of contamination, and repeatability issues. We report on a probe fixture designed for use in a commercial transmission electron microscope that enables repeatable mounting of multiple AFM probes as well as a reference grid for beam alignment. This communication describes the design, fabrication, and advantages of this probe fixture, including full technical drawings for machining. Further, best practices are discussed for repeatable, non-destructive probe imaging. Finally, examples of the fixture’s use are described, including characterization of common commercial AFM probes in their out-of-the-box condition.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

White light interferometry for quantitative surface characterization in ion sputtering experiments.

White light interferometry (WLI) can be used to obtain surface morphology information on dimensional scale of millimeters with lateral resolution as good as {approx}1 {micro}m and depth resolution down to 1 nm. By performing true three-dimensional imaging of sample surfaces, the WLI technique enables accurate quantitative characterization of the geometry of surface features and compares favorably to scanning electron and atomic force microscopies by avoiding some of their drawbacks. In this paper, results of using the WLI imaging technique to characterize the products of ion sputtering experiments are reported. With a few figures, several example applications of the WLI method are illustrated when used for (i) sputtering yield measurements and time-to-depth conversion, (ii) optimizing ion beam current density profiles, the shapes of sputtered craters, and multiple ion beam superposition and (iii) quantitative characterization of surfaces processed with ions. In particular, for sputter depth profiling experiments of {sup 25}Mg, {sup 44}Ca and {sup 53}Cr ion implants in Si (implantation energy of 1 keV per nucleon), the depth calibration of the measured depth profile curves determined by the WLI method appeared to be self-consistent with TRIM simulations for such projectile-matrix systems. In addition, high depth resolution of the WLI method is demonstrated for a case of a Genesis solar wind Si collector surface processed by gas cluster ion beam: a 12.5 nm layer was removed from the processed surface, while the transition length between the processed and untreated areas was 150 {micro}m.

99 GENERAL AND MISCELLANEOUS↗

Local structural and compositional determination via electron scattering: Heterogeneous Cu(001)-Pd surface alloy

We have measured the structure and chemical composition of ultrathin Pd films on Cu(001) using low-energy electron microscopy. We determine their local stoichiometry and structure, with 8.5 nm lateral spatial resolution, by quantitatively analyzing the scattered electron intensity and comparing it to dynamical scattering calculations, as in a conventional low-energy electron diffraction (LEED)-IV analysis. The average t-matrix approximation is used to calculate the total atomic scattering matrices for this random substitutional alloy. As in the traditional LEED analysis, the structural and compositional parameters are determined by comparing the computed diffraction intensity of a trial structure to that measured in experiment. Monte Carlo simulations show how the spatial and compositional inhomogeneity can be used to understand the energetics of Cu-Pd bonding.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

High-Resolution Electron Microscopy and Kinetic Studies of Precipitation Hardening Reactions in Cast Al-5.8Zn-2.2Mg-2.5Cu

Precipitation age hardening (T6) response of Al-5.8Zn-2.2Mg-2.5Cu alloy in near-net-shaped cast condition was investigated. Cast samples were manufactured using the controlled diffusion solidification (CDS) technology combined with a metallic mold tilt pour gravity casting process. This study was conducted using (1) non-isothermal aging during differential scanning calorimetry (DSC) experiments and (2) isothermal aging during which transient bulk and micro-hardness measurements taken at four aging temperatures of 343, 393, 433 and 473 K. A detailed microstructural investigation combined with a quantitative image analysis was carried out on both DSC and hardness specimens using high-resolution electron microscopy (HREM) and energy-dispersive spectroscopy (EDS) elemental mappings. Hardness measurements were analyzed using a kinetic modeling approach (single state variable combined with a kinetic equation that is valid for the Al-Zn-Mg-Cu alloys). The results confirm the formation of hardening phases of GP zone, intermediate hardening metastable phase η′ and equilibrium phase η. The results of calorimetric measurements, electron microscopy and selected area diffraction patterns are in good agreement and confirm transient precipitation/dissolution sequences. A mean value of activation energy Q{sub A} of 75 kJ/mol was evaluated for combined bulk diffusion rate of alloying elements during precipitation of strengthening phases within Al matrix.

36 MATERIALS SCIENCE↗

Transport of intensity equation: a tutorial

When it comes to “phase measurement” or “quantitative phase imaging”, many people will automatically connect them with “laser” and “interferometry”. Indeed, conventional quantitative phase imaging and phase measurement techniques generally rely on the superposition of two beams with a high degree of coherence: complex interferometric configurations, stringent requirements on the environmental stabilities, and associated laser speckle noise severely limit their applications in optical imaging and microscopy. On a different note, as one of the most well-known phase retrieval approaches, the transport of intensity equation (TIE) provides a new non-interferometric way to access quantitative phase information through intensity only measurement. Despite the insufficiency for interferometry, TIE is applicable under partially coherent illuminations (like the Köhler’s illumination in a conventional microscope), permitting optimum spatial resolution, higher signal-to-noise ratio, and better image quality. In this tutorial, we give an overview of the basic principle, research fields, and representative applications of TIE, focus particularly on optical imaging, metrology, and microscopy. The purpose of this tutorial is twofold. It should serve as a self-contained introduction to TIE for readers with little or no knowledge of TIE. On the other hand, it attempts to give an overview of recent developments in this field. These results highlight a new era in which strict coherence and interferometry are no longer prerequisites for quantitative phase imaging and diffraction tomography, paving the way toward new generation label-free three-dimensional microscopy, with applications in all branches of biomedicine.

42 ENGINEERING↗

X‐ray scattering reveals disordered linkers and dynamic interfaces in complexes and mechanisms for DNA double‐strand break repair impacting cell and cancer biology

Abstract Evolutionary selection ensures specificity and efficiency in dynamic metastable macromolecular machines that repair DNA damage without releasing toxic and mutagenic intermediates. Here we examine non‐homologous end joining (NHEJ) as the primary conserved DNA double‐strand break (DSB) repair process in human cells. NHEJ has exemplary key roles in networks determining the development, outcome of cancer treatments by DSB‐inducing agents, generation of antibody and T‐cell receptor diversity, and innate immune response for RNA viruses. We determine mechanistic insights into NHEJ structural biochemistry focusing upon advanced small angle X‐ray scattering (SAXS) results combined with X‐ray crystallography (MX) and cryo‐electron microscopy (cryo‐EM). SAXS coupled to atomic structures enables integrated structural biology for objective quantitative assessment of conformational ensembles and assemblies in solution, intra‐molecular distances, structural similarity, functional disorder, conformational switching, and flexibility. Importantly, NHEJ complexes in solution undergo larger allosteric transitions than seen in their cryo‐EM or MX structures. In the long‐range synaptic complex, X‐ray repair cross‐complementing 4 (XRCC4) plus XRCC4‐like‐factor (XLF) form a flexible bridge and linchpin for DNA ends bound to KU heterodimer (Ku70/80) and DNA‐PKcs (DNA‐dependent protein kinase catalytic subunit). Upon binding two DNA ends, auto‐phosphorylation opens DNA‐PKcs dimer licensing NHEJ via concerted conformational transformations of XLF‐XRCC4, XLF–Ku80, and LigIV BRCT –Ku70 interfaces. Integrated structures reveal multifunctional roles for disordered linkers and modular dynamic interfaces promoting DSB end processing and alignment into the short‐range complex for ligation by LigIV. Integrated findings define dynamic assemblies fundamental to designing separation‐of‐function mutants and allosteric inhibitors targeting conformational transitions in multifunctional complexes.

59 BASIC BIOLOGICAL SCIENCES↗

Multiscale operando X-ray investigations provide insights into electro-chemo-mechanical behavior of lithium intercalation cathodes

The electrochemical performance and cycle life of lithium-ion batteries (LIBs) depend on the electrochemical, chemical, and mechanical behavior of electrodes and electrolytes. Despite extensive studies conducted previously, challenges exist to decouple these behaviors, capture the evolution of electro-chemo-mechanical behavior in realistic conditions, and correlate atomic-scale stress evolution to micro-scale bulk mechanical degradation. Here, we report multiscale operando techniques to investigate polydisperse battery electrodes by integrating volume-averaged quantitative synchrotron X-ray scattering with high-resolution transmission X-ray microscopy (TXM). The former provides us information spanning a wide spatial range, from Angstrom-level atomic structures to micrometer-level particle scales, while the latter provides time-resolved 2D images of the particles during cycling. The complementarity of the two operando techniques is demonstrated by an over-lithiation test of LiCoO 2 electrodes, where particles crack and eventually pulverize. Additionally, the techniques are applied to study LiCoO 2 cycling stability from 3.0 V to 4.5 V. Operando X-ray scattering result shows nanometer-scale features keep forming in LiCoO 2 electrodes during cycling, resulting in an increased projected area observed by the TXM experiment. The formation of such features is inhibited by a polymer coating on the electrode, leading to vastly improved cycling stability. The polymer coating alleviates LiCoO 2 surface deterioration, reduces side product generation, and inhibits LiCoO 2 particles volume expansion during the cycling test. These operando multimodal X-ray techniques presented herein thus offer a novel, multiscale diagnostic modality for studying existing and emerging battery materials, aiding the development of next-generation LIBs.

25 ENERGY STORAGE↗

On the relationship between non-stoichiometry and passivity breakdown in ultra-thin oxides: combined depth-dependent spectroscopy, Mott-Schottky analysis and molecular dynamics simulation studies

Understanding the relationship between non-stoichiometry and physical properties of ultra-thin oxides is of great importance from both scientific and technological aspects. A specific example includes the onset of passivity breakdown in an ultra-thin oxide film in aqueous medium leading to the onset of corrosion. In this work, using the model system of ultra-thin oxide of alumina on aluminum synthesized by natural oxidation and photon-assisted oxidation processes; we demonstrate a direct correlation between passivity and quality of the oxide film quantitatively. Depth-dependent high resolution X-ray photoelectron spectroscopy (XPS), transmission electron microscopy (TEM) and nuclear reaction analysis (NRA) have been performed to characterize the physical and chemical properties of the oxide films, while detailed impedance measurements and Mott-Schottky studies have been performed to understand electronic transport. Combined NRA and TEM analysis reveal an 18% increase in oxygen density (for oxide films with near identical thicknesses ~3.8nm) in case of photon-assisted oxidation. The denser oxide film results in a ~34% more blockage of chloride ions transport as indicated by XPS analysis. Mott Schottky measurements on these oxide films indicates a 43% reduction of defect levels for UV-synthesized alumina when compared to native one, suggestive of chloride ion transport via oxygen vacancies. Additionally, molecular dynamics simulations have been performed to provide insights into the structure of the oxides at the atomic level to correlate with the experimental measurements. These simulations employ dynamic charge transfer between atoms and are used to investigate nanoscale oxides grown on Al (100) surfaces due to atomic and molecular oxygen. Oxidation using molecular and atomic oxygen resulted in an amorphous oxide scale with self limiting thickness of ~ 16 and 22 Å, respectively at 300 K. Structural and dynamic correlations indicate significant charge transfer to exist in the oxide film in both the cases. The oxide growth in both the cases occurs due to the inward oxygen and outward cation diffusion. The calculated in-plane and out-of-plane atomic diffusivities are 40-70% higher in case of atomic oxidation. In the presence of atomic oxygen, the O/Al ratio is more uniform and varies from 1.37 at the oxide-gas interface to 1.30 at metal-oxide interface whereas that formed by natural oxidation was sub-stoichiometric and oxygen deficient with O/Al values varying from 1.27 (oxide-gas interface) to 1.05 (metal-oxide interface) at room temperature. The simulation results are consistent with the reported experimental investigations.

36 MATERIALS SCIENCE↗

DefectTrack: a deep learning-based multi-object tracking algorithm for quantitative defect analysis of in-situ TEM videos in real-time

Abstract In-situ irradiation transmission electron microscopy (TEM) offers unique insights into the millisecond-timescale post-cascade process, such as the lifetime and thermal stability of defect clusters, vital to the mechanistic understanding of irradiation damage in nuclear materials. Converting in-situ irradiation TEM video data into meaningful information on defect cluster dynamic properties (e.g., lifetime) has become the major technical bottleneck. Here, we present a solution called the DefectTrack , the first dedicated deep learning-based one-shot multi-object tracking (MOT) model capable of tracking cascade-induced defect clusters in in-situ TEM videos in real-time. DefectTrack has achieved a Multi-Object Tracking Accuracy (MOTA) of 66.43% and a Mostly Tracked (MT) of 67.81% on the test set, which are comparable to state-of-the-art MOT algorithms. We discuss the MOT framework, model selection, training, and evaluation strategies for in-situ TEM applications. Further, we compare the DefectTrack with four human experts in quantifying defect cluster lifetime distributions using statistical tests and discuss the relationship between the material science domain metrics and MOT metrics. Our statistical evaluations on the defect lifetime distribution suggest that the DefectTrack outperforms human experts in accuracy and speed.

42 ENGINEERING↗

Femtosecond Coherent Anti-Stokes Raman Spectroscopy (CARS) As Next Generation Nonlinear LIDAR Spectroscopy and Microscopy

Nonlinear spectroscopy using coherent anti-Stokes Raman scattering and femtosecond laser pulses has been successfully developed as powerful tools for chemical analysis and biological imaging. Recent developments show promising possibilities of incorporating CARS into LIDAR system for remote detection of molecular species in airborne particles. The corresponding theory is being developed to describe nonlinear scattering of a mesoscopic particle composed of complex molecules by laser pulses with arbitrary shape and spectral content. Microscopic many-body transform theory is used to compute the third order susceptibility for CARS in molecules with known absorption spectrum and vibrational modes. The theory is combined with an integral scattering formula and Mie-Lorentz formulae, giving a rigorous formalism which provides powerful numerical experimentation of CARS spectra, particularly on the variations with the laser parameters and the direction of detection.

74 ATOMIC AND MOLECULAR PHYSICS↗

A brief history of 50 years of ICXOM

The ICXOM series of meetings began in 1956 and for over 50 years have been conferences devoted to the topic of 'X-ray microanalysis', both for those interested in developing instrumentation and methods of analysis and for scientists mainly interested in using X-ray micro-analysers for investigations of an applied nature. This contribution surveys the ICXOM series origins, its development and trends over the years.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The X-ray Fluorescence Microscopy Beamline at the Australian Synchrotron

A hard x-ray micro-nanoprobe has commenced operation at the Australian Synchrotron providing versatile x-ray fluorescence microscopy across an incident energy range from 4 to 25 keV. Two x-ray probes are used to collect {mu}-XRF and {mu}-XANES for elemental and chemical microanalysis: a Kirkpatrick-Baez mirror microprobe for micron resolution studies and a Fresnel zone plate nanoprobe capable of 60-nm resolution. Some unique aspects of the beamline design and operation are discussed. An advanced energy dispersive x-ray fluorescence detection scheme named Maia has been developed for the beamline, which enables ultrafast x-ray fluorescence microscopy.

36 MATERIALS SCIENCE↗

Ambient dependence of the phase of nanowires grown by annealing brass

The growth of oxide nanowires has been studied by the annealing of brass (Cu 65%, Zn 35%) at different annealing temperatures and in different ambient. The annealing temperature was varied from 400 deg. C to 650 deg. C. Scanning Electron Microscope (SEM) results showed that the temperature has a significant effect on the density and size of the nanowires. The annealing temperature of 600 deg. C was found to be optimum for the growth of nanowires. The growth at 600 deg. C was observed in two ambient-air and moist nitrogen. Selected Area Electron Diffraction (SAED) and Energy Dispersive Spectroscopy (EDS) results on Transmission Electron Microscope (TEM) showed that with changing the ambient from air to moist nitrogen, the phase of the nanowires changed from Zn doped CuO to Cu doped ZnO. This result can be of significance importance as it suggests the use of ambient for the tuning of phase of oxide nanowires and in turn for the tuning of their physical properties.

36 MATERIALS SCIENCE↗

Investigation of Microscopic Materials Limitations of Superconducting RF Cavities

The high-field performance of SRF cavities is often limited by breakdown events below the intrinsic limiting surface fields of Nb, and there is abundant evidence that these breakdown events are localized in space inside the cavity. Also, there is a lack of detailed understanding of the causal links between surface treatments and ultimate RF performance at low temperatures. An understanding of these links would provide a clear roadmap for improvement of SRF cavity performance, and establish a cause-and-effect ‘RF materials science’ of Nb. We propose two specific microscopic approaches to addressing these issues. First is a spatially-resolved local microwave-microscope probe that operates at SRF frequencies and temperatures to discover the microscopic origins of breakdown, and produce quantitative measurements of RF critical fields of coatings and films. Second, RF Laser Scanning Microscopy (LSM) has allowed visualization of RF current flow and sources of nonlinear RF response in superconducting devices with micro-meter spatial resolution. The LSM will be used in conjunction with surface preparation and characterization techniques to create definitive links between physical and chemical processing steps and ultimate cryogenic microwave performance. We propose to develop RF laser scanning microscopy of small-sample Nb pieces to establish surface-processing / RF performance relations through measurement of RF current distributions on micron-length scales and low temperatures.

36 MATERIALS SCIENCE↗