Search NASA⌕ Search

SEARCH · Search NASA

Results for “rendering”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

Systematics of aligned axions

We describe a novel technique that renders theories of N axions tractable, and more generally can be used to efficiently analyze a large class of periodic potentials of arbitrary dimension. Such potentials are complex energy landscapes with a number of local minima that scales as $\sqrt{N!}$ ,and so for large N appear to be analytically and numerically intractable. Our method is based on uncovering a set of approximate symmetries that exist in addition to the N periods. These approximate symmetries, which are exponentially close to exact, allow us to locate the minima very efficiently and accurately and to analyze other characteristics of the potential. We apply our framework to evaluate the diameters of flat regions suitable for slow-roll inflation, which unifies, corrects and extends several forms of “axion alignment” previously observed in the literature. We find that in a broad class of random theories, the potential is smooth over diameters enhanced by N 3/2 compared to the typical scale of the potential. To this end, a Mathematica implementation of our framework is available online.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Detecting a boosted diboson resonance

New light scalar particles in the mass range of hundreds of GeV, decaying into a pair of W/Z bosons can appear in several extensions of the SM. The focus of collider studies for such a scalar is often on its direct production, where the scalar is typically only mildly boosted. The observed W/Z are therefore well-separated, allowing analyses for the scalar resonance in a standard fashion as a low-mass diboson resonance. In this work we instead focus on the scenario where the direct production of the scalar is suppressed, and it is rather produced via the decay of a significantly heavier (a few TeV mass) new particle, in conjunction with SM particles. Such a process results in the scalar being highly boosted, rendering the W/Z’s from its decay merged. The final state in such a decay is a “fat” jet, which can be either four pronged (for fully hadronic W/Z decays), or may be like a W/Z jet, but with leptons buried inside (if one of the W/Z decays leptonically). In addition, this fat jet has a jet mass that can be quite different from that of the W/Z/Higgs/top quark-induced jet, and may be missed by existing searches. In this work, we develop dedicated algorithms for tagging such multi-layered “boosted dibosons” at the LHC. As a concrete application, we discuss an extension of the standard warped extra dimensional framework where such a light scalar can arise. We demonstrate that the use of these algorithms gives sensitivity in mass ranges that are otherwise poorly constrained.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

WIMP cogenesis for asymmetric dark matter and the baryon asymmetry

We propose a new mechanism where asymmetric dark matter (ADM) and the baryon asymmetry are both generated in the same decay chain of a metastable weakly interacting massive particle (WIMP) after its thermal freezeout. Dark matter and baryons are connected by a generalized baryon number that is conserved, while the DM asymmetry and baryon asymmetry compensate each other. This unified framework addresses the DM-baryon coincidence while inheriting the merit of the conventional WIMP miracle in predicting relic abundances of matter. Examples of renormalizable models realizing this scenario are presented. These models generically predict ADM with sub-GeV to GeV-scale mass that interacts with Standard Model quarks or leptons, thus rendering potential signatures at direct detection experiments sensitive to low mass DM. Other interesting phenomenological predictions are also discussed, including: LHC signatures of new intermediate particles with color or electroweak charge and DM induced nucleon decay; the long-lived WIMP may be within reach of future high energy collider experiments.

79 ASTRONOMY AND ASTROPHYSICS↗

Tracking Replicate Divergence in Microbial Community Composition and Function in Experimental Microcosms

The study of microbial community functions necessitates replicating microbial communities. Variation in community development over time renders this an imperfect process. Thus, anticipating the likely degree of variation among replicate communities may aid in experimental design. We examined divergence in replicate community composition and function among 128 naturally assembled starting communities obtained from soils, each replicated three times, following a 30-day microcosm incubation period. Bacterial and fungal communities diverged in both composition and function among replicates, but remained much more similar to each other than to communities from different starting inocula. Variation in bacterial community composition among replicates was, however, correlated with variation in dissolved organic carbon production. A smaller-scale experiment testing nine starting communities showed that divergence was similar whether replicates were incubated on sterile or non-sterile pine litter, suggesting the impact of a pre-existing community on replicate divergence is minor. However, replicates in this experiment which were incubated for 114 days diverged more than those incubated for 30 days, suggesting experiments that run over long time periods will likely see greater variation among replicate community composition. Here these results suggest that while replicates diverge at a community level, such divergence is unlikely to severely impede the study of community function.

59 BASIC BIOLOGICAL SCIENCES↗

Pictorial review on abdominal applications of ferumoxytol in MR imaging

Though gadolinium-based contrast agents are the most widely used contrast media in MR for clinical use, problems with nephrogenic systemic fibrosis and tissue deposition render their safety debatable, at least in a selected patient population. Ferumoxytol has the potential to be used as an alternate contrast medium for various clinical applications across multiple organs. It has prolonged intravascular signal and delayed intracellular macrophage uptake which are unique properties compared to gadolinium-based agents. This pictorial review aims to review the current and potential clinical applications of ferumoxytol as a contrast agent in abdominal MR imaging.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Cytological Sampling Versus Forceps Biopsy During Percutaneous Transhepatic Biliary Drainage and Analysis of Factors Predicting Success

Purpose: To assess the accuracy of cytological sampling and forceps biopsy in obstructing biliary lesions and to identify factors predictive of success. Methods: Consecutive patients (n = 119) with suspected malignant inoperable obstructive jaundice treated with percutaneous transhepatic biliary drainage during 7 years were included (60 male; mean age 72.5 years). All patients underwent forceps biopsy plus cytological sampling by washing the forceps device in cytological solution. Patient history, procedural and pathological records, and clinical follow-up were reviewed. Statistical analysis included chi-square test and multivariate regression analysis. Results: Histological diagnosis after forceps biopsy was more successful than cytology: Sensitivity was 78 versus 61%, and negative predictive value was 30 versus 19%. Cytology results were never positive when the forceps biopsy was negative. The cytological sample was negative and forceps sample positive in 2 cases of cholangiocarcinoma, 16 cases of pancreatic carcinoma, and 1 case of benign disease. Diagnostic accuracy was predicted by low bilirubin (p < 0.001), aspartate transaminase (p < 0.05), and white cell count (p {<=} 0.05). Conclusions: This technique is safe and effective and is recommended for histological diagnosis during PTBD in patients with inoperable malignant biliary strictures. Diagnostic yield is greater when bilirubin levels are low and there is no sepsis; histological diagnosis by way of forceps biopsy renders cytological sampling unnecessary.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Image Fusion of Preprocedural CTA with Real-time Fluoroscopy to Guide Proper Hepatic Artery Catheterization During Transarterial Chemoembolization of Hepatocellular Carcinoma: A Feasibility Study

To assess feasibility of proper hepatic artery catheterization using a 3D model obtained from preprocedural computed tomographic angiography (CTA), fused with real-time fluoroscopy, during transarterial chemoembolization of hepatocellular carcinoma. Twenty consecutive cirrhotic patients with hepatocellular carcinoma undergoing transarterial chemoembolization were prospectively enrolled onto the study. The early arterial phase axial images of the preprocedural CTA were postprocessed on an independent workstation connected to the angiographic system (Innova 4100; GE Healthcare, Milwaukee, WI), obtaining a 3D volume rendering image (VR) that included abdominal aorta, splanchnic arteries, and first and second lumbar vertebrae. The VR image was manually registered to the real-time X-ray fluoroscopy, with the lumbar spine used as the reference. The VR image was then used as guidance to selectively catheterize the proper hepatic artery. The procedure was considered successful when performed with no need for intraarterial contrast injections or angiographic acquisitions. The procedure was successful in 19 (95 %) of 20 patients. In one patient, celiac trunk angiography was required for the presence of a significant ostial stenosis that was underestimated at computed tomography. Time for image reconstruction and registration was <10 min in all cases. The use of preprocedural CTA model with fluoroscopy enables confident and direct catheterization of the proper hepatic artery with no need for preliminary celiac trunk angiography, thus reducing radiation exposure and contrast media administration.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Microwave Ablation (MWA) for the Treatment of a Solitary, Chemorefractory Testicular Cancer Liver Metastasis

We present a case of a patient with stage IIIC metastatic seminoma with a persistent chemorefractory liver lesion. The patient was deemed a poor surgical candidate due to the tumor’s aggressive biology with numerous other liver lesions treated with chemotherapy and a relatively high probability for additional recurrences. Further chemotherapy with curative intent was not a feasible option due to the fact that the patient had already received second-line high-dose chemotherapy and four cycles of third-line treatment complicated by renal failure, refractory thrombocytopenia, and debilitating neuropathy. After initial failure of laser, microwave ablation of the chemorefractory liver metastasis resulted in prolonged local tumor control and rendered the patient disease-free for more than 35 months, allowing him to regain an improved quality of life.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Impact of 3D Rotational Angiography on Liver Embolization Procedures: Review of Technique and Applications

In the last years, the interest into interventional applications of C-arm cone-beam CT (CBCT) progressively raised, widening its clinical application from the original field of interventional neuroradiology to the field of peripheral procedures. Liver embolization procedures, due to their complexity and potential treatment-related life-threatening complications, represent one of the main clinical applications of this novel angiographic technique. CBCT has been demonstrated to render procedures safer and technically easier, and to predict outcome as well as to avoid major complications in different treatment scenarios (trans-arterial embolization, trans-arterial chemoembolization, selective internal radiation therapy, percutaneous portal vein embolization). This review summarizes all technical, dosimetric and procedural aspects of CBCT techniques, underlying all its potential clinical advantages in the field of liver embolization procedures. Moreover, the paper provides all the instructions to obtain the best diagnostic performance out of this novel angiographic technique.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Multipath Curved Planar Reformations of Peripheral CT Angiography: Diagnostic Accuracy and Time Efficiency

ObjectivesTo compare diagnostic performance and time efficiency between 3D multipath curved planar reformations (mpCPRs) and axial images of CT angiography for the pre-interventional assessment of peripheral arterial disease (PAD), with digital subtraction angiography as the standard of reference.MethodsForty patients (10 females, mean age 72 years), referred to CTA prior to endovascular treatment of PAD, were prospectively included and underwent peripheral CT angiography. A semiautomated toolbox was used to render mpCPRs. Twenty-one arterial segments were defined in each leg; for each segment, the presence of stenosis > 70% was assessed on mpCPRs and axial images by two readers, independently, with digital subtraction angiography as gold standard.ResultsBoth readers reached lower sensitivity (Reader 1: 91 vs. 94%, p = 0.08; Reader 2: 89 vs. 93%, p = 0.03) but significantly higher specificity (Reader 1: 94 vs. 89%, p < 0.01; Reader 2: 96 vs. 95%, p = 0.01) with mpCPRs than with axial images. Reader 1 achieved significantly higher accuracy with mpCPRs (93 vs. 91%, p = 0.02), and Reader 2 had similar overall accuracy in both evaluations (94 vs. 94%, p = 0.96). Both readers read mpCPRs significantly faster than axial images (Reader 1: 5′45″ based on mpCPRs vs. 7′40″ based on axial images; Reader 2: 4′41″ based on mpCPRs vs. 6′57″ based on axial images; p < 0.01).ConclusionsmpCPRs are a promising 3D reformation technique that facilitates a fast assessment of PAD with high diagnostic accuracy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Arms Down Cone Beam CT Hepatic Angiography Performance Assessment: Vascular Imaging Quality and Imaging Artifacts

IntroductionThe practice of positioning patients’ arms above the head during catheter-injected hepatic arterial phase cone beam CT (A-CBCT) imaging has been inherited from standard CT imaging due to image quality concerns, but interrupts workflow and extends procedure time. We sought to assess A-CBCT image quality and artifacts with arms extended above the head versus down by the side.MethodsWe performed an IRB approved retrospective evaluation of reformatted and 3D-volume rendered images from 91 consecutive A-CBCTs (43 arms up, 48 arms down) acquired during hepatic tumor arterial embolization procedures. Two interventional radiologists reviewed all A-CBCT imaging and assigned vessel visualization scores (VVS) from 1 to 5, ranging from non-diagnostic to optimal visualization. Streak artifacts across axial images were rated from 1 to 3 based on resulting image quality (none to significant). Presence of respiratory or cardiac motion during acquisition, body mass index and radiation dose area product (DAP) were also recorded and analyzed. Univariate and multivariate analyses were used to assess the impact of arm position on VVS and imaging artifacts.ResultsVVS were not significantly associated with arm position during A-CBCT imaging. One reader reported more streak artifacts across axial images in the arms down group (p = 0.005). DAP was not statistically different between the groups (23.9 Gy cm{sup 2} [6.1–73.4] arms up, 26.1 Gy cm{sup 2} [4.2–102.6] arms down, p = 0.54).ConclusionA-CBCT angiography performed with the arms above the head is not superior for clinically relevant hepatic vascular visualization compared to imaging performed with the arms by the patient’s side.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Image Fusion Guidance with Pre-procedural CT with Real-Time Fluoroscopy for Adrenal Venous Sampling

PurposeTo assess the effectiveness of image fusion guidance (IF) with pre-procedural computed tomography (CT) with intraprocedural fluoroscopy for adrenal venous sampling (AVS).Materials and MethodsAVS before and after ACTH stimulation including bilateral segmental sampling of effluent tributaries was performed in 62 patients with IF. A 3D volume rendering image, including adrenal glands and veins extracted from previously obtained contrast-enhanced CT images, was manually registered to the real-time X-ray fluoroscopy. The technical success rates, procedure time, radiation exposure, and volume of contrast medium used were compared with 49 patients who underwent AVS without IF.ResultsNo significant differences in the technical success rates with and without IF were observed (98.4 vs. 91.8% for the right adrenal veins, p = 0.168, and 98.4 vs. 100% for the left adrenal veins, p = 1.000). The procedure time with IF was significantly shorter than that without IF (95.6 ± 18.8 vs. 108.4 ± 20.0 min, p = 0.001). The total dose-area product with IF was significantly lower than that without IF (43.1 ± 30.7 vs. 72.2 ± 45.3 Gy cm{sup 2}, p < 0.001). The contrast medium volume used with IF was significantly lower than that without IF (54.6 ± 21.9 vs. 65.7 ± 27.6 mL, p = 0.020).ConclusionsAlthough the contribution to improving the technical success rates was small in our study, IF can effectively reduce procedure time, radiation exposure, and volume of contrast medium during AVS.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Application of morphological synthesis for understanding electrode microstructure evolution as a function of applied charge/discharge cycles

Morphological analysis and synthesis operations were employed for analysis of electrode microstructure transformations and evolution accompanying the application of charge/discharge cycles to electrochemical storage systems (batteries). Using state-of-the-art morphological algorithms, it was possible to predict microstructure evolution in porous Si electrodes for Li-ion batteries with sufficient accuracy. Algorithms for image analyses (segmentation, feature extraction, and 3D-reconstructions using 2D-images) were also developed. Altogether, these techniques could be considered supplementary to phase-field mesoscopic approach to microstructure evolution that is based upon clear and definitive changes in the appearance of microstructure. However, unlike in phase-field, the governing equations for morphological approach are geometry-, not physics-based. Similar non-physics based approach to understanding different phenomena was attempted with the introduction of cellular automata. It is anticipated that morphological synthesis and analysis will represent a useful supplementary tool to phase-field and will render assistance to unraveling the underlying microstructure-property relationships. The paper contains data on electrochemical characterization of different electrode materials that was conducted in parallel to morphological study.

25 ENERGY STORAGE↗

Dot tracking methodology for background-oriented schlieren (BOS)

We propose here a dot tracking methodology for processing background-oriented schlieren (BOS) images. The technique improves the accuracy, precision and spatial resolution compared to conventional cross-correlation algorithms. Our methodology utilizes the prior information about the dot pattern such as the location, size and number of dots to provide near 100% yield even for high dot densities (20 dots/32 × 32 pixels) and is robust to image noise. Furthermore, we propose an improvement to the displacement estimation step in the tracking process, especially for noisy images, using a “correlation correction”, whereby we combine the spatial resolution benefit of the tracking method and the smoothing property of the correlation method to increase the dynamic range of the overall measurement process. We evaluate the performance of the method with synthetic BOS images of buoyancy-driven turbulence rendered using ray-tracing simulations, and experimental images of flow in the exit plane of a converging–diverging nozzle. The results show that the improved spatial resolution results in a better accuracy of the tracking method compared to correlation-based methods in regions with sharp displacement gradients, and the correlation correction step reduces the noise floor of the measurement, resulting in a fourfold improvement in the dynamic range.

42 ENGINEERING↗

On the nonlinearity of spatial scales in extreme weather attribution statements

In the context of continuing climate change, extreme weather events are drawing increasing attention from the public and news media. A question often asked is how the likelihood of extremes might have changed by anthropogenic greenhouse-gas emissions. Answers to the question are strongly influenced by the model used, duration, spatial extent, and geographic location of the event—some of these factors often overlooked. Using output from four global climate models, we provide attribution statements characterised by a change in probability of occurrence due to anthropogenic greenhouse-gas emissions, for rainfall and temperature extremes occurring at seven discretised spatial scales and three temporal scales. An understanding of the sensitivity of attribution statements to a range of spatial and temporal scales of extremes allows for the scaling of attribution statements, rendering them relevant to other extremes having similar but non-identical characteristics. This is a procedure simple enough to approximate timely estimates of the anthropogenic contribution to the event probability. Furthermore, since real extremes do not have well-defined physical borders, scaling can help quantify uncertainty around attribution results due to uncertainty around the event definition. Results suggest that the sensitivity of attribution statements to spatial scale is similar across models and that the sensitivity of attribution statements to the model used is often greater than the sensitivity to a doubling or halving of the spatial scale of the event. The use of a range of spatial scales allows us to identify a nonlinear relationship between the spatial scale of the event studied and the attribution statement.

54 ENVIRONMENTAL SCIENCES↗

McCormick envelopes in mixed-integer PDE-constrained optimization

McCormick envelopes are a standard tool for deriving convex relaxations of optimization problems that involve polynomial terms. Such McCormick relaxations provide lower bounds, for example, in branch-and-bound procedures for mixed-integer nonlinear programs but have not gained much attention in PDE-constrained optimization so far. This lack of attention may be due to the distributed nature of such problems, which on the one hand leads to infinitely many linear constraints (generally state constraints that may be difficult to handle) in addition to the state equation for a pointwise formulation of the McCormick envelopes and renders bound-tightening procedures that successively improve the resulting convex relaxations computationally intractable. We analyze McCormick envelopes for a model problem class that is governed by a semilinear PDE involving a bilinearity and integrality constraints. We approximate the nonlinearity and in turn the McCormick envelopes by averaging the involved terms over the cells of a partition of the computational domain on which the PDE is defined. This yields convex relaxations that underestimate the original problem up to an a priori error estimate that depends on the mesh size of the discretization. These approximate McCormick relaxations can be improved by means of an optimization-based bound-tightening procedure. We show that their minimizers converge to minimizers to a limit problem with a pointwise formulation of the McCormick envelopes when driving the mesh size to zero. We provide a computational example, for which we certify all of our imposed assumptions. The results point to both the potential of the methodology and the gaps in the research that need to be closed. Our methodology provides a framework first for obtaining pointwise underestimators for nonconvexities and second for approximating them with finitely many linear inequalities in an infinite-dimensional setting.

Approximations and Expansions↗

Linear two-pool models are insufficient to infer soil organic matter decomposition temperature sensitivity from incubations

Abstract Terrestrial carbon (C)-climate feedbacks depend strongly on how soil organic matter (SOM) decomposition responds to temperature. This dependency is often represented in land models by the parameter Q 10 , which quantifies the relative increase of microbial soil respiration per 10 °C temperature increase. Many studies have conducted paired laboratory soil incubations and inferred “active” and “slow” pool Q 10 values by fitting linear two-pool models to measured respiration time series. Using a recently published incubation study (Qin et al. in Sci Adv 5(7):eaau1218, 2019) as an example, here we first show that the very high parametric equifinality of the linear two-pool models may render such incubation-based Q 10 estimates unreliable. In particular, we show that, accompanied by the uncertain initial active pool size, the slow pool Q 10 can span a very wide range, including values as high as 100, although all parameter combinations are producing almost equally good model fit with respect to the observations. This result is robust whether or not interactions between the active and slow pools are considered (typically these interactions are not considered when interpreting incubation data, but are part of the predictive soil carbon models). This very large parametric equifinality in the context of interpreting incubation data is consistent with the poor temporal extrapolation capability of linear multi-pool models identified in recent studies. Next, using a microbe-explicit SOM model (RESOM), we show that the inferred two pools and their associated parameters (e.g., Q 10 ) could be artificial constructs and are therefore unreliable concepts for integration into predictive models. We finally discuss uncertainties in applying linear two-pool (or more generally multiple-pool) models to estimate SOM decomposition parameters such as temperature sensitivities from laboratory incubations. We also propose new observations and model structures that could enable better process understanding and more robust predictive capabilities of soil carbon dynamics.

54 ENVIRONMENTAL SCIENCES↗

A Resorbable Calcium-Deficient Hydroxyapatite Hydrogel Composite for Osseous Regeneration

It was previously discovered that the unique structure and chemistry of bacterial cellulose (BC) permits the formation of calcium-deficient hydroxyapatite (CdHAP) nanocrystallites under aqueous conditions at ambient pH and temperature. In this study, BC was chemically modified via a limited periodate oxidation reaction to render the composite degradable and thus more suitable for bone regeneration. While native BC does not degrade in mammalian systems, periodate oxidation yields dialdehyde cellulose which breaks down at physiological pH. The composite was characterized by tensile testing, X-ray diffraction, Fourier transform infrared spectroscopy, and scanning electron microscopy. X-ray diffraction showed that oxidized BC retains its structure and could biomimetically form CdHAP. Degradation behavior was analyzed by incubating the samples in simulated physiological fluid (pH 7.4) at 37 C under static and dynamic conditions. The oxidized BC and oxidized BC-CdHAP composites both lost significant mass after exposure to the simulated physiological environment. Examination of the incubation solutions by UV-Vis spectrophotometric analysis demonstrated that, while native BC released only small amounts of soluble cellulose fragments, oxidized cellulose releases carbonyl containing degradation products as well as soluble cellulose fragments. By entrapping CdHAP in a degradable hydrogel carrier, this composite should elicit bone regeneration then resorb over time to be replaced by new osseous tissue.

60 APPLIED LIFE SCIENCES↗