Search NASA⌕ Search

SEARCH · Search NASA

Results for “response surface methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

In Vitro and in Vivo Analyses of the Effects of Source, Length, and Charge on the Cytotoxicity and Immunocompatibility of Cellulose Nanocrystals

Cellulose nanocrystals (CNCs) are an emergent, sustainable nanomaterial which are bio-sourced, abundant, and biodegradable. On account of their high aspect ratio, low density, and mechanical rigidity, they have been employed in numerous areas of biomedical research including as reinforcing materials for bone or tissue scaffolds or as carriers in drug delivery systems. Given the promise of these materials for such use, characterizing and understanding their interactions with biological systems is an important step to prevent toxicity or inflammation. Reported herein are studies aimed at exploring the in-vitro and in-vivo effects that source, length, and charge of the CNCs have on cytotoxicity and immune response. In this study, CNCs from four different biosources (cotton, wood, Miscanthus x. Giganteus, and sea tunicate) were prepared and functionalized with positive or negative charges to obtain a small library of CNCs with a range of dimensions and surface charge. A method to remove endotoxic or other impurities on the CNC surface leftover from the isolation process was developed, and the biocompatibility of the CNCs was subsequently assayed in-vitro and in-vivo. After subcutaneous injection, it was found that unfunctionalized (uncharged) CNCs form aggregates at the site of injection, inducing splenomegaly and neutrophil infiltration, while charged CNCs having surface carboxylates, sulfate half-esters, or primary amines were biologically inert. No effect of particle source or length was observed in the in-vitro and in-vivo studies conducted. The lack of in-vitro or in-vivo immune response toward charged CNCs in these experiments supports their use in future biological studies.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Nanoporous aluminum oxide membranes coated with atomic layer deposition-grown titanium dioxide for biomedical applications: An in vitro evaluation

The surface topographies of nanoporous anodic aluminum oxide (AAO) and titanium dioxide (TiO 2 ) membranes have been shown to modulate cell response in orthopedic and skin wound repair applications. In this study, we: (1) demonstrate an improved atomic layer deposition (ALD) method for coating the porous structures of 20, 100, and 200 nm pore diameter AAO with nanometer-thick layers of TiO 2 and (2) evaluate the effects of uncoated AAO and TiO 2 -coated AAO on cellular responses. The TiO 2 coatings were deposited on the AAO membranes without compromising the openings of the nanoscale pores. The 20 nm TiO 2 -coated membranes showed the highest amount of initial protein adsorption via the micro bicinchoninic acid (micro-BOA) assay; all of the TiO 2 -coated membranes showed slightly higher protein adsorption than the uncoated control materials. Cell viability, proliferation, and inflammatory responses on the TiO 2 -coated AAO membranes showed no adverse outcomes. For all of the tested surfaces, normal increases in proliferation (DNA content) of L929 fibroblasts were observed over from 4 hours to 72 hours. No increases in TNF-alpha production were seen in RAW 264.7 macrophages grown on TiO 2 -coated AAO membranes compared to uncoated AAO membranes and tissue culture polystyrene (TOPS) surfaces. Both uncoated AAO membranes and TiO 2 -coated AAO membranes showed no significant effects on cell growth and inflammatory responses. In conclusion, the results suggest that TiO 2 -coated AAO may serve as a reasonable prototype material for the development of nanostructured wound repair devices and orthopedic implants.

36 MATERIALS SCIENCE↗

Metal Oxide Nanoarrays for Chemical Sensing: A Review of Fabrication Methods, Sensing Modes, and Their Inter-correlations

In recent years, engineered nanostructure assemblies such as nanowire arrays have attracted much research attention due to their unique chemical and functional characteristics collectively. The engineered nano-assemblies usually carry the characteristics distinct from bulk as a result of a size effect in their comprised elemental building blocks. The nanoscale size induced high surface-to-volume ratio is a fundamental attribute responsible for various chemical and physical properties required in various technologically important applications such as catalysts and sensors. This review article surveys the latest progress in engineered metal oxide nanostructure arrays, i.e., nanoarrays, for advanced chemical sensors' design and application. It starts with an overview of gaseous chemical sensors followed by surveys of various fabrication methods and routes for metal oxide nanoarrays. Different sensing modes and corresponding applications have been highlighted in the mixed gaseous chemical sensing, which provides new approaches and perspectives to meet the challenges of selective gas sensing, such as the cross-sensitivity and inter-correlation of multiple sensing signals.

36 MATERIALS SCIENCE↗

Subtask 1.5 – CO2 Injection Monitoring with an Optimized Scalable, Automated, Semipermanent Seismic Array

The scalable, automated, semipermanent seismic array (SASSA) method is a flexible and relatively cost-effective surface geophysical method for regular time-lapse monitoring of the movement of injected carbon dioxide (CO2) in a reservoir for CO2 enhanced oil recovery (EOR) or geologic CO2 storage operations. It has the advantages of a low-environmental-footprint while monitoring regions of a reservoir from the surface without the need for a regular grid distribution of receivers. Automated data collection is possible. As only time-lapse amplitude changes at the reservoir level due to CO2 movement within the reservoir are monitored, the turnaround time to deliver results from the SASSA method can be short, without the need for long, time-consuming data-processing workflows. As data is collected and processed, incremental information can be provided to the field operator. The Energy & Environmental Research Center (EERC) conducted a SASSA field test from September 2018 to November 2020 in a portion of the Bell Creek Field in Montana, which implemented new CO2 EOR field activities during the study period. Lessons learned from a proof-of-concept study were incorporated to improve the data quality of the SASSA method and demonstrate the viability of the technology. The EERC implemented several enhancements to improve data quality, including 1) an iterative survey design, which allowed placing the receivers in strategic locations where the movement of the CO2 in the reservoir could be tracked with minimum interference by the cultural noise in the study area; 2) the use of powerful seismic sources in the form of surface orbital vibrators, and 3) data acquisition during optimal periods. History-matched reservoir simulation was performed to predict gas saturation and pressure response induced by CO2 injection in the study area. The results were compared with the SASSA-measured responses to CO2 injection as a partial validation technique. A match between the two methods was observed for most of the SASSA points predicted to have intersected a CO2 saturation change. The validated results provide confidence that the SASSA method can be used independently as a CO2 saturation monitoring technique. As data are collected and processed, incremental information can be provided to the field operator. The critical components of the SASSA workflow for a successful application of the method are the following: Iterative survey design with information about CO2 injection activities from the oilfield operator. A detailed CO2 injection plan is the key driver to select the strategic monitoring location of the SASSA sensors. After this information is incorporated in the initial distribution of sources and receivers in the study area, high-resolution satellite images are used to identify ground locations not affected by cultural noise sources, such as power lines, pipelines/flow lines, or roadways. In the next iteration of the survey design, a scouting trip to the study area is needed to understand more details of the noise sources identified in the previous step and the intensity of the field activities that can also generate noise during the monitoring. Integrating the information from the scouting trip into the survey design to select the optimum source and receiver locations is the final step. Noise attenuation. The variety of noise types during seismic monitoring of an oil field is enormous. Tailored noise characterization and processing at a node-by-node level can enhance the performance and sensitivity of the SASSA technique. Future advancements that could improve the efficiency and application of the SASSA technology include: Gaining a better understanding of the noise field produced by the seismic source to aid the choice of receiver location. Surface noise from the source can overwhelm the small signal changes due to CO2 that the SASSA method measures. Improved data-processing workflow to automatically analyze and adapt to dynamic noise conditions associated with industrial settings. This subtask was funded through the EERC–DOE Joint Program on Research and Development for Fossil Energy-Related Resources Cooperative Agreement No. DE- FE0024233.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

SU-F-T-70: A High Dose Rate Total Skin Electron Irradiation Technique with A Specific Inter-Film Variation Correction Method for Very Large Electron Beam Fields

Purpose: Rotational total skin electron irradiation (RTSEI) is used in the treatment of cutaneous T-cell lymphoma. Due to inter-film uniformity variations the dosimetry measurement of a large electron beam of a very low energy is challenging. This work provides a method to improve the accuracy of flatness and symmetry for a very large treatment field of low electron energy used in dual beam RTSEI. Methods: RTSEI is delivered by dual angles field a gantry of ±20 degrees of 270 to cover the upper and the lower halves of the patient body with acceptable beam uniformity. The field size is in the order of 230cm in vertical height and 120 cm in horizontal width and beam energy is a degraded 6 MeV (6 mm of PMMA spoiler). We utilized parallel plate chambers, Gafchromic films and OSLDs as a measuring devices for absolute dose, B-Factor, stationary and rotational percent depth dose and beam uniformity. To reduce inter-film dosimetric variation we introduced a new specific correction method to analyze beam uniformity. This correction method uses some image processing techniques combining film value before and after radiation dose to compensate the inter-variation dose response differences among films. Results: Stationary and rotational depth of dose demonstrated that the Rp is 2 cm for rotational and the maximum dose is shifted toward the surface (3mm). The dosimetry for the phantom showed that dose uniformity reduced to 3.01% for the vertical flatness and 2.35% for horizontal flatness after correction thus achieving better flatness and uniformity. The absolute dose readings of calibrated films after our correction matched with the readings from OSLD. Conclusion: The proposed correction method for Gafchromic films will be a useful tool to correct inter-film dosimetric variation for the future clinical film dosimetry verification in very large fields, allowing the optimizations of other parameters.

60 APPLIED LIFE SCIENCES↗

Tamper-Indicating Enclosures with Visually Obvious Tamper Response (Final Project Report)

Sandia National Laboratories is developing a new method for detecting penetration of tamper - indicating enclosures (TIEs). This method incorporates the use of "bleeding" materials (analogous to visually obvious, colorful bruised skin that doesn't heal) into the design of TIEs. As designed, it will allow inspectors to use simple visual observation to detect attempts to penetrate the external surfaces of a TIE, without providing adversaries the ability to repair damage. A material of this type can enhance tamper indication of current TIEs used to support treaty verification regimes. Current TIE inspections are time - consuming and rely on subjective visual assessment by an inspector, equipment such as eddy current or camera devices, or involve approaches that may be limited due to application environment. The complexities and requirements that volumetric sealing methods (or TIEs) must address are: (1) enclosures that are non - standard in size/shape; (2) enclosures that may be inspectorate - or facility - owned; (3) finding tamper attempts that are difficult and time consuming for an inspector to locate; (4) enclosures that are reliable and durable enough to survive the conditions that exist in the operating environment (including facility handling); and (5) methods that prevent adversaries from repairing penetrations. Early project R&D [1] focused on encapsulated transition metals. Due to the challenges associated with the transition metal - based approach, a mitigation approach was investigated resulting in two separate research paths — one that involves fabricating custom TIE molds that meet the specific (size and shape) needs of safeguards equipment a nd one that can be deployed as a sprayed on or painted coating to an existing TIE or surface. The "custom mold" approach is based on creating thin layers of materials that , when penetrated, expose an inner material to O 2 which causes an irreversible color change. The "in-situ coating" approach is based on applying a sensor solution containing color changing microcapsules that bleed when the microcapsule is ruptured. The anticipated benefits of this work are passive, flexible, scalable, robust , cost-effective TIEs with visually obvious responses to tamper attempts. This provides more efficient and effective monitoring , as inspectors will require little or no additional equipment and will be able to detect tamper without extensive time - consuming visual examination. Applications include custom TIEs (cabinets , equipment enclosures or seal bodies ), or spray-coating/painting onto facility-owned items, walls or structures, or circuit boards. The paper describes research and testing completed to-date on the method and integration of select system components.

36 MATERIALS SCIENCE↗

Squeezing Out Interfacial Solvation: The Role of Hydrogen-Bonding in the Structural and Orientational Freedom of Molecular Self-Assembly

We report bioinspired membrane molecules with improved physical properties and enhanced stability can serve as functional models for conventional lipid or amphiphilic species. Importantly, these molecules can also provide new insights into emergent phenomena that manifest during self-assembly at interfaces. Here, we elucidate the structural response and mechanistic steps underlying the self-assembly of the amphiphilic, charged oligodimethylsiloxane imidazolium cation (ODMS-MIM+) at the air–aqueous interface using Langmuir trough methods with coincident surface-specific vibrational sum-frequency generation (SFG) spectroscopy. We find evidence for a new compression-induced desolvation step that precedes commonly known disordered-to-ordered phase transitions to form nanoscopic assemblies. The experimental data was supported by atomistic molecular dynamics (MD) simulations to provide a detailed mechanistic picture underlying the assembly and the role of water in these phase transitions. The sensitivity of the hydrophobic ODMS tail conformations to compression-owing to distinct water–ODMS interactions and tail–tail solvation properties-offers new strategies for the design of interfaces that can be further used to develop soft-matter electronics and low-dimensional materials using physical and chemical controls.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

NETL Plastic Pipes Project - June 2022 Progress Report

Plastic or composite pipelines have been the bane of the utility locating industry because conduits are neither conductive nor magnetic, which are the properties traditionally used to locate buried utilities. Ground penetrating radar (GPR) is an effective geophysical tool for locating plastic/composite pipeline where the resistive cover allows for adequate penetration of radar energy. However, GPR cannot be used in areas where the soil cover is conductive due to significant clay and/or salt content. This study takes a comprehensive look at near-surface geophysical methods that potentially are useful for locating buried plastic/composite pipelines, either singly or in combination with other geophysical methods. Specifically, this modeling study uses computational numerical methods to forward model the response of GPR, resistivity, seismic, and gravity gradiometry methods to plastic/composite pipelines for various scenarios including: (1) pipe diameters ranging between 2 in. to 12 in.; (2) burial depths ranging between 3 ft to 4 ft; (3) various degrees in contrast in physical properties (i.e., permittivity, elasticity, electrical resistivity, density); and (4) various experimental acquisition choices (e.g., GPR radar frequencies, seismic source frequency, electrode spacing).

47 OTHER INSTRUMENTATION↗

Microwave remote sensing of soil water content

Microwave remote sensing of soils to determine water content was considered. A layered water balance model was developed for determining soil water content in the upper zone (top 30 cm), while soil moisture at greater depths and near the surface during the diurnal cycle was studied using experimental measurements. Soil temperature was investigated by means of a simulation model. Based on both models, moisture and temperature profiles of a hypothetical soil were generated and used to compute microwave soil parameters for a clear summer day. The results suggest that, (1) soil moisture in the upper zone can be predicted on a daily basis for 1 cm depth increments, (2) soil temperature presents no problem if surface temperature can be measured with infrared radiometers, and (3) the microwave response of a bare soil is determined primarily by the moisture at and near the surface. An algorithm is proposed for monitoring large areas which combines the water balance and microwave methods.

Cihlar, J.↗

On the Sensitivity of Piezoceramics and Piezopolymers in Structural Integrity Monitoring of Large Trusses

An analytical assessment has been made of the reliability of using integrated microactuators and sensors in the form of piezoceramics and piezopolymers as joint integrity monitors in trussed systems. The concept is first implemented for a simple structure which consists of two truss members with a 45 deg lift angle joined at the apex. A piezoceramic patch (or piezopolymer film) bonded on the surface of one of the members at a location near the joint is used as a collocated actuator/sensor. The overall structural dynamic response under an excitation was modeled by finite element method. Different degrees of nodal constraints at the joints representing various degrees of joint integrity are employed. The resulting dynamic response showed distinct responses for varying joint stiffnesses. Parallel experimental work on a truss model using a multichannel data acquisition system and a digital signal analyzer confirms the results from analysis. We further studied the sensitivity of the micro-sensors to the behavior of joints of large arch truss structure. Results obtained for large trusses with many degrees of freedom indicate optimum locations of sensors for which the dynamic response signatures are distinct and distinguishable for relatively small changes in joint integrity and/or structural geometry. Computations based on finite element modeling show that locating the single actuator/sensor at the joint corresponding to the first loss of static stability appear optimal. Hence, static stability analysis of complex trusses can give us a good indication of the optimum placement of sensors for maximum response. This observation is important if few distributed sensors and actuators are available for placement in constructed facilities made from large trusses with many degrees of freedom. As an extension of this work a dynamic response signature identification technique to monitor in-service degradation of joints is under development for application to the monitoring of the integrity of adhesive joints in composite structures.

Abatan, A. O.↗

New Computer Simulations of Macular Neural Functioning

We use high performance graphics workstations and supercomputers to study the functional significance of the three-dimensional (3-D) organization of gravity sensors. These sensors have a prototypic architecture foreshadowing more complex systems. Scaled-down simulations run on a Silicon Graphics workstation and scaled-up, 3-D versions run on a Cray Y-MP supercomputer. A semi-automated method of reconstruction of neural tissue from serial sections studied in a transmission electron microscope has been developed to eliminate tedious conventional photography. The reconstructions use a mesh as a step in generating a neural surface for visualization. Two meshes are required to model calyx surfaces. The meshes are connected and the resulting prisms represent the cytoplasm and the bounding membranes. A finite volume analysis method is employed to simulate voltage changes along the calyx in response to synapse activation on the calyx or on calyceal processes. The finite volume method insures that charge is conserved at the calyx-process junction. These and other models indicate that efferent processes act as voltage followers, and that the morphology of some afferent processes affects their functioning. In a final application, morphological information is symbolically represented in three dimensions in a computer. The possible functioning of the connectivities is tested using mathematical interpretations of physiological parameters taken from the literature. Symbolic, 3-D simulations are in progress to probe the functional significance of the connectivities. This research is expected to advance computer-based studies of macular functioning and of synaptic plasticity.

Ross, Muriel D.↗

Development, Verification and Validation of Enclosure Radiation Capabilities in the CHarring Ablator Response (CHAR) Code

With the recent development of multi-dimensional thermal protection system (TPS) material response codes including the capabilities to account for radiative heating is a requirement. This paper presents the recent efforts to implement such capabilities in the CHarring Ablator Response (CHAR) code developed at NASA's Johnson Space Center. This work also describes the different numerical methods implemented in the code to compute view factors for radiation problems involving multiple surfaces. Furthermore, verification and validation of the code's radiation capabilities are demonstrated by comparing solutions to analytical results, to other codes, and to radiant test data.

Salazar, Giovanni↗

Understanding the origin of Tabula Rasa-induced defects in n-type Cz c-Si: The case of nitrogen atmosphere

Phosphorus-doped Czochralski-grown silicon (Cz-Si) has been gaining market share in the large-scale manufacturing of high-efficiency silicon (Si)-based photovoltaic (PV) devices thanks to higher carrier lifetimes than their boron-doped counterpart. However, the fabrication of n-type Cz-Si based solar cells often requires process steps with much higher temperatures and longer times than p-type Silicon. Defect interaction with the high temperatures during such processes tend to be detrimental to the n-type Cz-Si carrier lifetime, therefore limiting the final device efficiency. Short thermal anneals before cell processing, known as Tabula Rasa (TR), have been proposed to mitigate the thermally induced lifetime degradation during n-type Cz-Si solar cell fabrication. This work thoroughly investigates the defects responsible for the lifetime degradation after TR in a N 2 atmosphere treatment. We use temperature-injection-dependent lifetime spectroscopy and the thickness variation method to decouple the effects of TR treatment in the bulk and the surface of the n-type Cz-Si wafers. Using the defect parameter contour mapping (DPCM), we identify the defect energy level (E t ) and the capture cross-section ratio (k) of the most likely process-induced defect, which aligns with previously proposed Si vacancy-associated defects. The DPCM reveals that these vacancy-associated defects have a shallow energy level E t - E v ~0.13 eV and very efficient electron capture cross section k~600. Unexpectedly, the bulk degradation due to vacancy defects in the volume of the wafer, is accompanied by a significant increase in the surface recombination as well. Through evaluating the surface recombination velocity temperature- and injection dependence, we show that after TR, at room temperature and for an injection level of 10 15 cm -3 , in a wafer passivated with a-Si:H(i) the surface recombination dominates the overall lifetime response. Here we hypothesize that the near surface vacancy-associated bulk defects play a role in lowering the electron diffusion current into the a-Si:H(i) from the c-Si(n) reducing the field-effect passivation.

14 SOLAR ENERGY↗

Aerothermodynamics of Pyrolizing Surfaces in Hypersonic Rarefied Flows

Direct simulation Monte Carlo (DSMC) calculations of rarefied flows about entry bodies typically employ a fixed surface temperature or a radiative-equilibrium energy balance to compute that temperature. Such boundary conditions neglect any effects of heat capacitance and heat conduction in the spacecraft heat shield and, therefore, provide an upper bound for the surface temperature. Such calculations also neglect pyrolysis from the heat shield which can be significant for a high-energy incident flow at very low densities. Accurate prediction of both heating and aerodynamic forces requires including pyrolysis and surface heat transfer in the models for gas-surface interaction employed in DSMC methods. Although these physical models have long appeared in various continuum flow calculation codes, they have only recently appeared in DSMC codes which are required to simulate rarefied flows during entry at high altitudes. In the current implementation, routines from the widely distributed Charring Material Thermal Response and Ablation (CMA) program are coupled into a DSMC code to calculate the one-dimensional heat transfer into the carbon phenolic heat shield at each point on a vehicle surface. Temperature-dependent material properties, surface re-radiation, and in-depth pyrolysis were included in the calculation, but surface ablation was neglected. Sample calculations for entry of the Galileo probe into the atmosphere of Jupiter demonstrate that including pyrolysis in the model leads to significant differences in predicted aerodynamics. Granted, the drag coefficient does not depend strongly on the surface temperature which can itself be significantly below the radiative equilibrium value during entry. However, the surface mass flux due to pyrolysis of the material is significant once the probe drops to altitudes characterized by transition flow. This leads to a noticeable increase in drag and a decrease in heating compared to a body without pyrolysis.

Haas, Brian L.↗

Developments in flow visualization methods for flight research

With the introduction of modern airplanes utilizing laminar flow, flow visualization has become an important diagnostic tool in determining aerodynamic characteristics such as surface flow direction and boundary-layer state. A refinement of the sublimating chemical technique has been developed to define both the boundary-layer transition location and the transition mode. In response to the need for flow visualization at subsonic and transonic speeds and altitudes above 20,000 feet, the liquid crystal technique has been developed. A third flow visualization technique that has been used is infrared imaging, which offers non-intrusive testing over a wide range of test conditions. A review of these flow visualization methods and recent flight results is presented for a variety of modern aircraft and flight conditions.

Holmes, Bruce J.↗

Autonomous Inversion of In Situ Deformation Measurement Data for Injection-Induced Stress Change

Geologic carbon storage (GCS) is likely to play a key part of the global effort to dramatically reduce CO2 emissions and perhaps even reduce atmospheric CO2 concentrations through carbon negative operations. A critical part of effort to commercialize and widely deploy this technology is developing the capability to rapidly assimilate real-time monitoring data into a form that will enable site operators to make decisions to manage the safe and efficient operations. Two of the risks associate with GCS are the risk of inducing fractures in the sealing formations that can create leakage pathways and the risk of inducing earthquakes of sufficient magnitude to cause public concern, property damage, or safety risks. To properly manage these risks the site operator needs to know the initial state of stress, the change in stress induced by injection, and the relationship between operational parameters such as injection rate and pressure and the change in stress. Current methods of estimating the change in stress require choosing the type of constitutive model and the model parameters based on core, log, and geophysical data during the characterization phase, with little feedback from operational observations to validate or refine these choices. These characterization methods interrogate the geologic formations using length scales, loading rates or magnitudes that are quite different from those encountered by the actual storage system. It is shown that errors in the assumed constitutive response, even when informed by laboratory tests on core samples, are likely to be common, large, and underestimate the magnitude of stress change caused by injection. Recent advances in borehole-based strain instruments and borehole and surface-based tilt and displacement instruments have now enabled monitoring of the deformation of the storage system throughout its operational lifespan. This data can enable validation and refinement of the knowledge of the geomechanical properties and state of the system, but brings with it a challenge to transform the raw data into actionable knowledge. We demonstrate a method that uses automatic differentiation and a finite-element based geomechanical model perform a gradient-based deterministic inversion of geomechanical monitoring data. This approach allows autonomous integration of the instrument data without the need for time consuming manual interpretation and selection of updated model parameters. Furthermore, only isotropic linear elasticity is considered in this paper, the approach presented is very flexible as to what type of geomechanical constitutive response can be used. The approach is easily adaptable to nonlinear physics-based constitutive models to account for common rock behaviors such as creep and plasticity. The approach also enables training of machine learning-based constitutive models by allowing back propagation of errors through the finite element calculations. This enables strongly enforcing known physics, such as conservation of momentum and continuity, while allowing data-driven models to learn the truly unknown physics such as the constitutive or petrophysical responses.

Burghardt, Jeffrey A.↗

Elucidating ultrafast electron dynamics at surfaces using extreme ultraviolet (XUV) reflection–absorption spectroscopy

Here we review the recent development of extreme ultraviolet reflection–absorption (XUV-RA) spectroscopy. This method combines the benefits of X-ray absorption spectroscopy, such as element, oxidation, and spin state specificity, with surface sensitivity and ultrafast time resolution, having a probe depth of only a few nm and an instrument response less than 100 fs. Using this technique we investigated the ultrafast electron dynamics at a hematite (α-Fe 2 O 3 ) surface. Surface electron trapping and small polaron formation both occur in 660 fs following photoexcitation. These kinetics are independent of surface morphology indicating that electron trapping is not mediated by defects. Instead, small polaron formation is proposed as the likely driving force for surface electron trapping. We also show that in Fe 2 O 3 , Co 3 O 4 , and NiO, band gap excitation promotes electron transfer from O 2p valence band states to metal 3d conduction band states. In addition to detecting the photoexcited electron at the metal M 2,3 -edge, the valence band hole is directly observed as transient signal at the O L 1 -edge. The size of the resulting charge transfer exciton is on the order of a single metal–oxygen bond length. Spectral shifts at the O L 1 -edge correlate with metal–oxygen bond covalency, confirming the relationship between valence band hybridization and the overpotential for water oxidation. Furthermore, these examples demonstrate the unique ability to measure ultrafast electron dynamics with element and chemical state resolution using XUV-RA spectroscopy. Accordingly, this method is poised to play an important role to reveal chemical details of previously unseen surface electron dynamics.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗