Search NASA⌕ Search

SEARCH · Search NASA

Results for “single photon source”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

Development of ARCHER towards clinical use: modeling and simulation of Varian Linac for radiation therapy dose calculations - 25449

Monte Carlo particle transport methods are well recognized as the most accurate approach to dose calculations for radiation therapy treatment planning. However, the lengthy calculation time has prevented Monte Carlo methods from being applied to dose calculations in the planning of radiation therapy. Recently, the emerging parallel computing hardware accelerators, such as general-purpose Graphics Processing Unit (GPU), have significantly boosted the performance of Monte Carlo codes. The accuracy of a clinical dose engine depends greatly on the accuracy of source term modeling and the methodology of dose calculations. Hence, in this study, an efficient and accurate source model of the Varian TrueBeam{sup R} Linac is developed and integrated with a fast photon-electron transport module of the recently developed high-performance Monte Carlo code, ARCHER. The validity of the source model and the particle transport physics are verified with established dose calculation codes such as EGSnrc and validated with experimental measurements. To demonstrate the capability of the platform in clinical applications, three clinical treatment plans (the lung, breast, and prostate) are simulated and analyzed. From the perspective of performance, the entire simulation of each clinical plan, starting from the source modeling to the end of particle transport within the patient phantom, can be finished in less than one minute using a single Titan X GPU card with 1% statistical error. In comparison, the same cases take the EGSnrc code hundreds of CPU hours to finish. The results suggest that this new version of ARCHER code has been successfully developed and tested as a clinically deployable dose engine for external photon beam IMRT plans in the clinical setting. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗

Two photon exchange with nuclei from $e^+/e^-$ elastic cross section ratios

Hadronic box diagrams pose a significant source of radiative corrections to lepton scattering and β -decay measurements, yet their calculation remains highly model-dependent. Two-photon exchange is a box diagram generally relevant to most lepton scattering experiments, and is directly detectable via multiple observables. Single-spin asymmetries (SSA) are sensitive to the imaginary part of the TPE amplitude, while the ratio of $e^+/e^-$ elastic scattering cross sections is sensitive to the real part of the TPE amplitude. While SSA measurements have been reported for several complex nuclei, measurements of the $e^+/e^-$ ratio exist only for the proton. Proposed here is a measurement of the $e^+/e^-$ ratio on 4 He, a feasible nuclear target for which the ratio’s deviation from unity due to TPE is expected to be on order of 1–2%. Choosing a low Z nucleus minimizes Coulomb distortions, which could greatly overwhelm TPE for heavier nuclei. The proposed 19-day program, including measurements at three kinematic settings between 0.3 < Q 2 < 0.4 GeV 2 , would be made possible by the addition of a positron source at Jefferson Lab.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Opticsconcept for apair of undulatorbeamlines for MX

We describe a concept for X-ray optics to feed a pair of macromolecular crystallography (MX) beamlines, which view canted undulator radiation sources in the same storage ring straight section. It can be deployed at NSLS-II and at other low-emittance third-generation synchrotron radiation sources where canted undulators are permitted, and makes the most of these sources and beamline floor space, even when the horizontal angle between the two canted undulator emissions is as little as 1-2 mrad. The concept adopts the beam-separation principles employed at the 23-ID (GM/CA-CAT) beamlines at the Advanced Photon Source (APS), wherein tandem horizontally deflecting mirrors separate one undulator beam from the other, following monochromatization by a double-crystal monochromator. The scheme described here would, in contrast, deliver the two tunable monochromatic undulator beams to separate endstations that address rather different and somewhat complementary purposes, with further beam conditioning imposed as required. A downstream micro-focusing beamline would employ dual-stage focusing for work at the micron scale and, unique to this design, switch to single-stage focusing for larger beams. On the other hand, the upstream, more highly automated beamline would only employ single-stage focusing.

43 PARTICLE ACCELERATORS↗

Effectiveness of Repeat Angiographic Assessment in Patients Designated for Radioembolization Using Yttrium-90 Microspheres With Initial Extrahepatic Accumulation of Technitium-99m Macroaggregated Albumin: A Single Center's Experience

Purpose: To evaluate the efficacy of a workflow consisting of repeat assessment in patients planned for yttrium-90 ({sup 90}Y) radioembolization in case of nontarget visceral technetium-99m ({sup 99m}Tc)-macroaggregated albumin (MAA) accumulation despite initial prophylactic coil embolization of nonhepatic arteries. Materials and Methods: In 341 patients with primary and secondary liver cancer, pretreatment hepatic angiograms, as well as single-photon emission computed tomography coregistered with magnetic resonance imaging scans, were obtained. Extrahepatic tracer deposition was identified in 33 patients (9.7%) necessitating repeat assessment. Images were reviewed to correlate the site of MAA accumulation with causative gastrointestinal vessels, and repeat angiograms served as reference standard. Results: At repeat angiography, the source of extrahepatic flow was identified and eliminated in 31 of 33 patients (93.9%). In 20 patients (60.6%), successful embolization of nontarget vessels was achieved, in 13 patients (39.4%), MAA was administered more distally. Afterward, extrahepatic MAA deposition was eliminated in 30 patients (90.9%). Conclusion: The algorithm of repeat assessment in case of extrahepatic MAA accumulation has proven highly effective to eliminate extrahepatic shunting, thus decreasing the risk of postradioembolization complications due to inadvertent visceral microsphere deposition.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Optical and X-Ray Early Follow-Up of ANTARES Neutrino Alerts

High-energy neutrinos could be produced in the interaction of charged cosmic rays with matter or radiation surrounding astrophysical sources. Even with the recent detection of extraterrestrial high-energy neutrinos by the IceCube experiment, no astrophysical neutrinosource has yet been discovered. Transient sources, such as gamma-ray bursts, core-collapse supernovae, or active galactic nuclei are promising candidates. Multi-messenger programs offer a unique opportunity to detect these transient sources. By combining the information provided by the ANTARES neutrino telescope with information coming from other observatories, the probability of detecting a source is enhanced, allowing the possibility of identifyinga neutrino progenitor from a single detected event. A method based on optical and X-ray follow-ups of high-energy neutrino alerts has been developed within the ANTARES collaboration. This method does not require any assumptions on the relation between neutrino and photon spectra other than time-correlation. This program, denoted as TAToO, triggers a network of robotic optical telescopes (TAROTand ROTSE) and the Swift-XRT with a delay of only a few seconds after a neutrino detection, and is therefore well-suited to search for fast transient sources. To identify an optical or Xraycounterpart to a neutrino signal, the images provided by the follow-up observations areanalysed with dedicated pipelines. A total of 42 alerts with optical and 7 alerts with X-ray images taken with a maximum delay of 24 hours after the neutrino trigger have been analyzed. No optical or X-ray counterparts associated to the neutrino triggers have been found, and upper limits on transient source magnitudes have been derived. The probability to reject the gamma-ray burst origin hypothesis has been computed for each alert.

X-ray telescopes↗

Absolute single photoionization cross-sections of Br 3+ : experiment and theory

Absolute single photoionization cross section measurements for Br 3+ ions are reported in the photon energy range 44.79-59.54 eV at a photon energy resolution of 21 ±3 meV. Measurements were performed at the Advanced Light Source at Lawrence Berkeley National Laboratory using the merged-beams technique. Numerous resonance features in the experimental spectrum are assigned and their energies and quantum defect values are tabulated. The cross-section measurements are also compared with Breit-Pauli R-matrix calculations with suitable agreement over the photon energy range investigated. Analysis of the measured spectrum including Rydberg resonance series identifications produced a new emperical determination of the ionizational potential of Br 3+ of 46.977 ± 0.050 eV, which is 805 meV lower than the most recently published value of 47.782 eV. Finally, this disparity between our determination and the earlier published value is similar to an 843 meV shift in the accepted ionization potential published for iso-electronic Se 2+ as part of this same research program.

74 ATOMIC AND MOLECULAR PHYSICS↗

Hard X-ray Fluorescence measurements with TESs at the Advanced Photon Source

Transition Edge Sensor (TES) spectrometers for hard X-ray beamline science will enable improved X-ray emission and absorption spectroscopy in the information-rich 2 to 20keV energy range. We are building a TES-based instrument for time Advanced Photon Source (APS) synchrotron, to be made available to beamline users. 24-pixel prototype arrays have recently been fabricated and tested. the first, spectroscopy measurements using these arrays are promising, with a best single-pixel energy resolution of 11.2 eV and saturation energy > 20 keV. We present a series of recent X-ray Fluorescence measurements involving transition metal elements and multi-element samples with closely spaced emission lines, in particular a Cu-Ni-Co thin film and a foil of Cu and Hf, The TES-measured spectra are directly compared to spectra measured with silicon drift detectors at an APS beamline, demonstrating the improved X-ray science made possible by TES spectrometers.

Guruswamy, Tejas↗

Explosive Detection in Aviation Applications Using CT

CT scanners are deployed world-wide to detect explosives in checked and carry-on baggage. Though very similar to single- and dual-energy multi-slice CT scanners used today in medical imaging, some recently developed explosives detection scanners employ multiple sources and detector arrays to eliminate mechanical rotation of a gantry, photon counting detectors for spectral imaging, and limited number of views to reduce cost. For each bag scanned, the resulting reconstructed images are first processed by automated threat recognition algorithms to screen for explosives and other threats. Human operators review the images only when these automated algorithms report the presence of possible threats. The US Department of Homeland Security (DHS) has requirements for future scanners that include dealing with a larger number of threats, higher probability of detection, lower false alarm rates and lower operating costs. One tactic that DHS is pursuing to achieve these requirements is to augment the capabilities of the established security vendors with third-party algorithm developers. A third-party in this context refers to academics and companies other than the established vendors. DHS is particularly interested in exploring the model that has been used very successfully by the medical imaging industry, in which university researchers develop algorithms that are eventually deployed in commercial medical imaging equipment. The purpose of this paper is to discuss opportunities for third-parties to develop advanced reconstruction and threat detection algorithms.

42 ENGINEERING↗

X-ray Laue Diffraction Microscopy in 3D at the Advanced Photon Source

Studies of materials on mesoscopic length-scales require a penetrating structural probe with submicron point-to-point spatial resolution. The principle research activities at beamline 34-ID-E of the Advanced Photon Source (APS) involve development of exciting new micro-/nano-diffraction techniques for characterization and microscopy in support of both applied engineering and fundamental materials research. Taking advantage of the high brightness of the source, advanced focusing mirrors, a novel depth profiling technique, and high-speed area detectors, three-dimensional scanning Laue diffraction microscopy provides detailed local structural information of crystalline materials, such as crystallographic orientation, orientation gradients, and strain tensors. It is general and applicable to single-crystal, polycrystalline, composite, deformed, and functionally graded materials. Applications include 3D diffraction investigations for a diverse and growing user community with interests in materials deformation, electro-migration, recrystallization, fatigue, solid-solution precipitation, high-pressure environments, and condensed matter physics.

43 PARTICLE ACCELERATORS↗

Optical and X-ray early follow-up of ANTARES neutrino alerts

High-energy neutrinos could be produced in the interaction of charged cosmic rays with matter or radiation surrounding astrophysical sources. Even with the recent detection of extraterrestrial high-energy neutrinos by the IceCube experiment, no astrophysical neutrino source has yet been discovered. Transient sources, such as gamma-ray bursts, core-collapse supernovae, or active galactic nuclei are promising candidates. Multi-messenger programs offer a unique opportunity to detect these transient sources. By combining the information provided by the ANTARES neutrino telescope with information coming from other observatories, the probability of detecting a source is enhanced, allowing the possibility of identifying a neutrino progenitor from a single detected event. A method based on optical and X-ray follow-ups of high-energy neutrino alerts has been developed within the ANTARES collaboration. This method does not require any assumptions on the relation between neutrino and photon spectra other than time-correlation. This program, denoted as TAToO, triggers a network of robotic optical telescopes (TAROT and ROTSE) and the Swift-XRT with a delay of only a few seconds after a neutrino detection, and is therefore well-suited to search for fast transient sources. To identify an optical or X-ray counterpart to a neutrino signal, the images provided by the follow-up observations are analysed with dedicated pipelines. A total of 42 alerts with optical and 7 alerts with X-ray images taken with a maximum delay of 24 hours after the neutrino trigger have been analysed. No optical or X-ray counterparts associated to the neutrino triggers have been found, and upper limits on transient source magnitudes have been derived. The probability to reject the gamma-ray burst origin hypothesis has been computed for each alert.

79 ASTRONOMY AND ASTROPHYSICS↗

Tuning a microcavity-coupled terahertz laser

Tunable oscillators are a key component of almost all electronic and photonic systems. Yet, a technology capable of operating in the terahertz (THz)-frequency range and fully suitable for widescale implementation is still lacking. This issue is significantly limiting potential THz applications in gas sensing, high-resolution spectroscopy, hyper-spectral imaging, and optical communications. The THz quantum cascade laser is arguably the most promising solution in terms of output power and spectral purity. In order to achieve reliable, repeatable, and broad tunability, here we exploit the strong coupling between two different cavity mode concepts: a distributed feedback one-dimensional photonic resonator (providing gain) and a mechanically actuated wavelength-size microcavity (providing tuning). The result is a continuously tunable, single-mode emitter covering a 162 GHz spectral range, centered on 3.2 THz. Our source has a few tens of MHz resolution, extremely high differential efficiency, and unprecedented compact and simple design architecture. By unveiling the large potential that lies in this technique, our results provide a robust platform for radically different THz systems exploiting broadly tunable semiconductor lasers.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A field programmable gate array-based timing and control system for the dynamic compression sector

A field programmable gate array (FPGA)-based timing and trigger control system has been developed for the Dynamic Compression Sector (DCS) user facility located at the Advanced Photon Source (APS) at Argonne National Laboratory. The DCS is a first-of-its-kind capability dedicated to dynamic compression science. All components of the DCS laser shock station—x-ray choppers, single-shot shutter, internal laser triggers, and shot diagnostics—must be synchronized with respect to the arrival of x rays in the hutch. An FPGA synchronized to the APS storage ring radio frequency clock (352 MHz) generates trigger signals for each stage of the laser and x-ray shutter system with low jitter. The developed FPGA-based control system was the first system used to control the laser and the shutter system since its commissioning, and it has been developing since then to improve the timing jitter. The system is composed of a Zynq FPGA, a debug card, line drivers, and a power supply. The delay and offsets of the trigger signals can be adjusted by using a user-friendly graphical user interface with high precision. Here, the details of the system architecture, timing requirements, firmware, and software implementation along with the performance evaluation are presented in this paper. The system offers low timing jitter (15.5 ps rms) with respect to the APS 352 MHz clock, suitable for the 100 ps (FWHM) x-ray bunch duration at the APS.

47 OTHER INSTRUMENTATION↗

Single Event Transients Induced by Picosecond Pulsed X-Ray Absorption in III-V Heterojunction Transistors

We perform measurements which show that focused, picosecond pulses of x-rays can be used to generate single event transients (SET) in a GaAs heterostructure field effect transistor (HFET) and a GaN high electron mobility transistor. X-ray pulses with photon energies of 8, 10 and 12 keV from the Advanced Photon Source at Argonne National Laboratory were used to excite transients. SETs are observed when x-ray pulses are incident upon metal layers above sensitive areas on the transistors. We use focused ion beam (FIB) cross-sectioning and scanning transmission electron microscopy energy dispersive x-ray spectroscopy (STEM-EDXS) to determine the compositional structure of the devices. We present a first order analysis of energy deposition in the devices and correlate it to the transient response to make preliminary interpretations of the results. We compare the x-ray transients from the GaAs HFET with transients generated by 750 nm and 870 nm femtosecond laser pulses. We also present results on the total dose susceptibility of the GaN HEMTs.

Cardoza, David M↗

Real-time machine-learning-driven control system of a deformable mirror for achieving aberration-free X-ray wavefronts

A neural-network machine learning model is developed to control a bimorph adaptive mirror to achieve and preserve aberration-free coherent X-ray wavefronts at synchrotron radiation and free electron laser beamlines. The controller is trained on a mirror actuator response directly measured at a beamline with a real-time single-shot wavefront sensor, which uses a coded mask and wavelet-transform analysis. The system has been successfully tested on a bimorph deformable mirror at the 28-ID IDEA beamline of the Advanced Photon Source at Argonne National Laboratory. It achieved a response time of a few seconds and maintained desired wavefront shapes (e.g., a spherical wavefront) with sub-wavelength accuracy at 20 keV of X-ray energy. This result is significantly better than what can be obtained using a linear model of the mirror’s response. The developed system has not been tailored to a specific mirror and can be applied, in principle, to different kinds of bending mechanisms and actuators.

47 OTHER INSTRUMENTATION↗

Diamond Photodiodes for X-ray Applications

Single crystal high purity CVD diamonds have been metallized and calibrated as photodiodes at the National Synchrotron Light Source (NSLS). Current mode responsivity measurements have been made over a wide range (0.2-28 keV) of photon energies across several beamlines. Linear response has been achieved over ten orders of magnitude of incident flux, along with uniform spatial response. A simple model of responsivity has been used to describe the results, yielding a value of 13.3 {+-} 0.5 eV for the mean pair creation energy. The responsivity vs. photon energy data show a dip for photon energies near the carbon edge (284 eV), indicating incomplete charge collection for carriers created less than one micron from the metallized layer.

43 PARTICLE ACCELERATORS↗

Diamond photodiodes for x-ray application

Single crystal high purity CVD diamonds have been metallized and calibrated as photodiodes at the National Synchrotron Light Source (NSLS). Current mode responsivity measurements have been made over a wide range (0.2-28 keV) of photon energies across several beamlines. Linear response has been achieved over ten orders of magnitude of incident flux, along with uniform spatial response. A simple model of responsivity has been used to describe the results, yielding a value of 13.3 {+-} 0.5 eV for the mean pair creation energy. The responsivity vs. photon energy data show a dip for photon energies near the carbon edge (284 eV), indicating incomplete charge collection for carriers created less than one micron from the metallized layer.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-T-46: Application of a Twin-Detector Method for the Determination of the Mean Photon Energy Em at Points of Measurement in a Water Phantom Surrounding a GammaMed HDR 192Ir Brachytherapy Source

Purpose: In a brachytherapy photon field in water the fluence-averaged mean photon energy Em at the point of measurement correlates with the radiation quality correction factor kQ of a non water-equivalent detector. To support the experimental assessment of Em, we show that the normalized signal ratio NSR of a pair of radiation detectors, an unshielded silicon diode and a diamond detector can serve to measure quantity Em in a water phantom at a Ir-192 unit. Methods: Photon fluence spectra were computed in EGSnrc based on a detailed model of the GammaMed source. Factor kQ was calculated as the ratio of the detector's spectrum-weighted responses under calibration conditions at a 60Co unit and under brachytherapy conditions at various radial distances from the source. The NSR was investigated for a pair of a p-type unshielded silicon diode 60012 and a synthetic single crystal diamond detector 60019 (both PTW Freiburg). Each detector was positioned according to its effective point of measurement, with its axis facing the source. Lateral signal profiles were scanned under complete scatter conditions, and the NSR was determined as the quotient of the signal ratio under application conditions x and that at position r-ref = 1 cm. Results: The radiation quality correction factor kQ shows a close correlation with the mean photon energy Em. The NSR of the diode/diamond pair changes by a factor of two from 0–18 cm from the source, while Em drops from 350 to 150 keV. Theoretical and measured NSR profiles agree by ± 2 % for points within 5 cm from the source. Conclusion: In the presence of the close correlation between radiation quality correction factor kQ and photon mean energy Em, the NSR provides a practical means of assessing Em under clinical conditions. Precise detector positioning is the major challenge.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗