Search NASA⌕ Search

SEARCH · Search NASA

Results for “spatial resolution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

Simulated scatter performance of an inverse-geometry dedicated breast CT system

The purpose of this work was to quantify the effects of scatter for inverse-geometry dedicated breast CT compared to cone-beam breast CT through simulations. The inverse geometry was previously proposed as an alternative to cone-beam acquisition for volumetric CT. The inverse geometry consists of a large-area scanned-source opposite a detector array that is smaller in the transverse direction. While the gantry rotates, the x-ray beam is rapidly sequenced through an array of positions, acquiring a truncated projection image at each position. Inverse-geometry CT (IGCT) is expected to detect less scatter than cone-beam methods because only a fraction of the object is irradiated at any time and the fast detector isolates the measurements from sequential x-ray beams. An additional scatter benefit is the increased air gap due to the inverted geometry. In this study, we modeled inverse-geometry and cone-beam dedicated breast CT systems of equivalent resolution, field of view, and photon fluence. Monte Carlo simulations generated scatter and primary projections of three cylindrical phantoms of diameters 10, 14, and 18 cm composed of 50% adipose/50% glandular tissue. The scatter-to-primary ratio (SPR) was calculated for each breast diameter. Monte Carlo simulations were combined with analytical simulations to generate inverse-geometry and cone-beam images of breast phantoms embedded with tumors. Noise representing the photon fluence of a realistic breast CT scan was added to the simulated projections. Cone-beam data were reconstructed with and without an ideal scatter correction. The CNR between breast tumor and background was compared for the inverse and cone-beam geometries for the three phantom diameters. Results demonstrated an order of magnitude reduction in SPR for the IGCT system compared to the cone-beam system. For example, the peak IGCT SPRs were 0.05 and 0.09 for the 14 and 18 cm phantoms, respectively, compared to 0.42 and 1 for the cone-beam system. For both geometries, the effects of scatter on contrast-to-noise ratio (CNR) were small for the 10 cm diameter phantom. The inverse-geometry improved the CNR by factors of 1.16 for the 14 cm phantom and 1.48 for the 18 cm phantom compared to a cone-beam acquisition without scatter correction. When an ideal scatter correction was applied to the cone-beam acquisition, the IGCT CNR improvements were 1.03 and 1.25 for the 14 and 18 cm phantoms. Overall, the results suggest that the inverse geometry may be advantageous for dedicated breast CT, an application that requires high-contrast resolution, spatial resolution, and dose efficiency.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

iCHORD-SI combination as an alternative to EDS-EBSD coupling for the characterization of γ-γ′ nickel-based superalloy microstructures

Highlights: • A new method to get orientation maps discriminating the gamma and gamma’ phases of Ni superalloys is described. • The method combines the iCHORD technique with secondary ion imaging. • The new method resolves precipitates down to 150 nm within a reasonable acquisition time. - Abstract: Because they exhibit very similar diffraction patterns, the γ and γ′ phases of nickel-based superalloys cannot be distinguished by the conventional EBSD technique alone. This paper presents an original method which discriminates those phases on an orientation map by exploiting their chemical differences. Performed with a Focused Ion Beam (FIB) microscope, the method is the combination of the ion CHanneling ORientation Determination technique (iCHORD) – recently developed by Langlois et al. [1] – with the chemical information obtained from Secondary Ion (SI) images. The performances of the method are compared to the EDS-EBSD coupling which also discriminates phases based on their chemical compositions. Applied filters, angular resolution, spatial resolution of the phase discrimination and acquisition time are discussed. It results that the iCHORD–SI combination offers an orientation map with an angular resolution slightly decreased compared to that of the EBSD technique, but with a good phase resolution (down to 150 nm) and within a reasonable acquisition time. Thus, the iCHORD–SI combination appears to be an interesting method for the crystallographic systems where phases are difficult to discriminate by the EBSD technique alone but present a significant chemical contrast.

36 MATERIALS SCIENCE↗

The Australian National Airborne Field Experiment 2005: Soil Moisture Remote Sensing at 60 Meter Resolution and Up

Spatially-distributed soil moisture observations have applications spanning a wide range of spatial resolutions from the very local needs of individual farmers to the progressively larger areas of interest to weather forecasters, water resource managers, and global climate modelers. To date, the most promising approach for space-based remote sensing of soil moisture makes use of passive microwave emission radiometers at L-band frequencies (1-2 GHz). Several soil moisture-sensing satellites have been proposed in recent years, with the European Space Agency's Soil Moisture Ocean Salinity (SMOS) mission scheduled to be launched first in a couple years. While such a microwave-based approach has the advantage of essentially allweather operation, satellite size limits spatial resolution to 10's of km. Whether used at this native resolution or in conjunction with some type of downscaling technique to generate soil moisture estimates on a finer-scale grid, the effects of subpixel spatial variability play a critical role. The soil moisture variability is typically affected by factors such as vegetation, topography, surface roughness, and soil texture. Understanding and these factors is the key to achieving accurate soil moisture retrievals at any scale. Indeed, the ability to compensate for these factors ultimately limits the achievable spatial resolution and/or accuracy of the retrieval. Over the last 20 years, a series of airborne campaigns in the USA have supported the development of algorithms for spaceborne soil moisture retrieval. The most important observations involved imagery from passive microwave radiometers. The early campaigns proved that the retrieval worked for larger and larger footprints, up to satellite-scale footprints. These provided the solid basis for proposing the satellite missions. More recent campaigns have explored other aspects such as retrieval performance through greater amounts of vegetation. All of these campaigns featured extensive ground truth collection over a range of grid spacings, to provide a basis for examining the effects of subpixel variability. However, the native footprint size of the airborne L-band radiometers was always a few hundred meters. During the recently completed (November, 2005) National Airborne Field Experiment (NAFE) campaign in Australia, a compact L-band radiometer was deployed on a small aircraft. This new combination permitted routine observations at native resolutions as high as 60 meters, substantially finer than in previous airborne soil moisture campaigns, as well as satellite footprint areal coverage. The radiometer, the Polarimetric L-band Microwave Radiometer (PLMR) performed extremely well and operations included extensive calibration-related observations. Thus, along with the extensive fine-scale ground truth, the NAFE dataset includes all the ingredients for the first scaling studies involving very-high-native resolution soil moisture observations and the effects of vegetation, roughness, etc. A brief overview of the NAFE will be presented, then examples of the airborne observations with resolutions from 60 m to 1 km will be shown, and early results from scaling studies will be discussed.

Kim, E. J.↗

IM3/HyperFACETS Thermodynamic Global Warming (TGW) Simulation Datasets

Publication For a thorough description of the methods, see the peer-reviewed paper: Jones, A.D., Rastogi, D., Vahmani, P. et al. Continental United States climate projections based on thermodynamic modification of historical weather. Sci Data 10, 664 (2023). https://doi.org/10.1038/s41597-023-02485-5 Overview The IM3 / HyperFACETS climate simulations provide 40-year historical (1980-2019) as well as four 80-year future simulations (2020-2099) over the U.S. The future simulations are split into near (2020-2059) and far future (2060-2099) segments. The future scenarios span a range of plausible changes in future climate (both Global Circulation Model (GCM) and Representative Concentration Pathways/Shared Socioeconomic Pathway (RCP/SSP) dimensions). The simulations provide climate variables with high spatiotemporal resolution (25 hourly variables and 207 3-hourly variables at 12 km2). The datasets are generated using dynamical downscaling with the WRF (Weather Research and Forecasting) model (version 4.2.1) and therefore preserve physical consistency across variables. WRF is a state-of-the-art, fully compressible, non-hydrostatic, mesoscale numerical weather prediction model. WRF is coupled with an urban canopy model (UCM), which resolves urban surfaces. The future scenarios were developed using a thermodynamic global warming approach where past events are replayed under a range of future warming conditions. These scenarios therefore provide a perspective on potential increases in extreme event intensity, geographic scope, and duration, with previously non-extreme conditions potentially crossing new thresholds to be considered extreme by today's standards. This approach is not intended to estimate future changes in extreme event frequency that might result from changes in large-scale atmospheric dynamics. This dataset has NOT been bias corrected. A bias corrected version of selected variables is under development and will be released here when available. Scenarios Files Data for each scenario is provided in weekly NetCDF files. 25 variables are available at hourly resolution, and 207 variables are available at three-hourly resolution. Spatial resolution is 12km and spans the conterminous United States (CONUS), including some areas of Canada and Mexico, resulting in a grid of 424 by 299 cells. The spatial projection is a Lambert Conformal Conic with the following proj-string: "+proj=lcc +lat_0=40.0000076293945 +lon_0=-97 +lat_1=30 +lat_2=45 +x_0=0 +y_0=0 +R=6370000 +units=m +no_defs". The available scenarios and simulation periods are listed below: historical | 1980 - 2019 rcp45cooler | 2020 - 2059 rcp45cooler | 2060 - 2099 rcp45hotter | 2020 - 2059 rcp45hotter | 2060 - 2099 rcp85cooler | 2020 - 2059 rcp85cooler | 2060 - 2099 rcp85hotter | 2020 - 2059 rcp85hotter | 2060 - 2099 * The first year (1979, 2019, and 2059) of data within each scenario represents a model warmup period and should not be used. These are located in the `spinup_files` directory. Historical year 2020 is considered an extra year of data beyond the simulation period and can be found in the `additional_files` directory. For information on specific variables and a more in-depth discussion of methodology, please refer to the data landing page at https://tgw-data.msdlive.org. Delta Warming Files The global and CONUS warming deltas for each scenario are provided in degrees Celsius annually and monthly. Restart Files Yearly restart files are provided for each scenario which can be used to restart the WRF model at a particular point in time. Spinup Files The first year of data within each simulation period represents a model warmup period and should not be used. The files are provided here for the sake of reproducibility. Additional Files Additional years of data are provided as an extension of the historic simulation.

Jones, Andrew D.↗

Performance characteristics of dedicated molecular breast imaging systems at low doses

Purpose: The purpose of this study was to compare the system performance characteristics and lesion detection capability of two molecular breast imaging (MBI) systems: a multicrystal sodium iodide (NaI)-based single-head system and a cadmium zinc telluride (CZT)-based dual-head system at low administered doses (150–300 MBq) of Tc-99m sestamibi. Methods: System performance characteristics including count sensitivity, uniformity, energy resolution, and spatial resolution were measured using standard NEMA methods, or a modified version thereof in cases where the standard NEMA protocol could not be applied. A contrast-detail phantom with 48 lesions at varying depths from the collimator surface was used to assess lesion contrast-to-noise-ratio (CNR) using background count densities comparable to those observed in patient studies performed with administered doses of 150 MBq Tc-99m sestamibi. Lesions with CNR >3 were deemed to be detectable. Thirty patients undergoing MBI examinations with administered doses of 150–300 MBq were scanned for an additional view on the pixelated NaI system. CNR was calculated for lesions observed on patient images. Background count densities of patient images were measured and compared between the two systems. Results: Over the central field of view, integral and differential uniformity were 6.1% and 4.2%, respectively, for the pixelated NaI system, and 3.8% and 2.7%, respectively, for the CZT system. Count sensitivity was 10.8 kcts/min/MBq for the NaI system and 32.9 kcts/min/MBq for the CZT system. Energy resolution was 13.5% on the pixelated NaI system and 4.5% on the CZT system. Spatial resolution (full-width at half-maximum) for the pixelated NaI detector was 4.2 mm at a distance of 1.2 cm from the collimator and 5.2 mm at 3.1 cm. Spatial resolution of a single CZT detector was 2.9 mm at a distance of 1.2 cm from the collimator and 4.7 mm at 3.1 cm. Effective spatial resolution obtained with dual-head CZT was below 4.7 mm throughout a simulated breast thickness of 6 cm. From contrast-detail phantom images of lesions at distances of 1.5–4.5 cm from the collimator face, the CZT system detected 124 of 144 (86%) of lesions compared to 97 of 144 (67%) with the NaI system. In patient studies, from comparison of the same view with both systems, a total of 7 breast lesions were identified on CZT system in seven patients, and 4 of 7 (57%) were detected on NaI system. Patient image background count densities on the CZT system were on average 3.4 times higher than those on the NaI system. Conclusions: The CZT system demonstrated better uniformity, count sensitivity, spatial resolution, energy resolution, and lesion detection in phantom and patient studies compared to the NaI system. At administered doses of 150–300 MBq Tc-99m sestamibi, patient results obtained with CZT systems may not be directly translatable to NaI systems.

60 APPLIED LIFE SCIENCES↗

Beyond Taylor’s hypothesis: a novel volumetric reconstruction of velocity and density fields for variable‑density and shear flows

Abstract This work presents a novel numerical procedure for reconstructing volumetric density and velocity fields from planar laser-induced fluorescence (PLIF) and stereoscopic particle image velocimetry (SPIV) data. This new method is theoretically and practically demonstrated to provide more accurate 3D vortical structures and density fields in high shear flows than reconstruction methods based on the mean convective velocity. While Taylor’s hypothesis of frozen turbulence is commonly applied by using the local mean streamwise velocity, the proposed algorithm uses the measured local instantaneous velocity for data convection. It consists of a step-by-step reconstruction based on a mixed Lagrangian–Eulerian solver that includes the 3D interpolation of scattered flow data and that relaxes the Taylor’s hypothesis by iterative enforcement of the incompressibility constraint on the velocity field. This methodology provides 3D fields with temporal resolution, spatial resolution, and accuracy comparable to that of real 3D snapshots, thus providing a practical alternative to tomographic measurements. The procedure is validated using numerical data of the constant-density channel flow available on the Johns Hopkins University Turbulence Database (JHTDB), showing the accurate reconstruction of the 3D velocity field. The algorithm is applied to an experimental dataset of PLIF and SPIV measurements of a variable-density jet flow, demonstrating its capability to provide 3D velocity and density fields that are more consistent with the Navier–Stokes equations compared to the mean flow convective method. Graphic abstract

42 ENGINEERING↗

Large‐Eddy Simulations of a Convection Cloud Chamber: Sensitivity to Bin Microphysics and Advection

Abstract Bin microphysics schemes are useful tools for cloud simulations and are often considered to provide a benchmark for model intercomparison. However, they may experience issues with numerical diffusion, which are not well quantified, and the transport of hydrometeors depends on the choice of advection scheme, which can also change cloud simulation results. Here, an atmospheric large‐eddy simulation model is adapted to simulate a statistically steady‐state cloud in a convection cloud chamber under well‐constrained conditions. Two bin microphysics schemes, a spectral bin method and the method of moments, as well as several advection methods for the transport of the microphysical variables are employed for model intercomparison. Results show that different combinations of microphysics and advection schemes can lead to considerable differences in simulated cloud properties, such as cloud droplet number concentration. We find that simulations using the advection scheme that suffers more from numerical diffusion tends to have a smaller droplet number concentration and liquid water content, while simulation with the microphysics scheme that suffers more from numerical diffusion tends to have a broader size distribution and thus larger mean droplet sizes. Sensitivities of simulations to bin resolution, spatial resolution, and temporal resolution are also tested. We find that refining the microphysical bin resolution leads to a broader cloud droplet size distribution due to the advection of hydrometeors. Our results provide insight for using different advection and microphysics schemes in cloud chamber simulations, which might also help understand the uncertainties of the schemes used in atmospheric cloud simulations.

54 ENVIRONMENTAL SCIENCES↗

Performance of the Tachyon Time-of-Flight PET Camera

We have constructed and characterized a time-of-flight Positron Emission Tomography (TOF PET) camera called the Tachyon. The Tachyon is a single-ring Lutetium Oxyorthosilicate (LSO) based camera designed to obtain significantly better timing resolution than the ~ 550 ps found in present commercial TOF cameras, in order to quantify the benefit of improved TOF resolution for clinically relevant tasks. The Tachyon's detector module is optimized for timing by coupling the 6.15 ×25 mm 2 side of 6.15 ×6.15 ×25 mm 3 LSO scintillator crystals onto a 1-inch diameter Hamamatsu R-9800 PMT with a super-bialkali photocathode. We characterized the camera according to the NEMA NU 2-2012 standard, measuring the energy resolution, timing resolution, spatial resolution, noise equivalent count rates and sensitivity. The Tachyon achieved a coincidence timing resolution of 314 ps +/- 20 ps FWHM over all crystal-crystal combinations. Experiments were performed with the NEMA body phantom to assess the imaging performance improvement over non-TOF PET. We find that the results show that at a matched contrast, incorporating 314 ps TOF reduces the standard deviation of the contrast by a factor of about 2.3.

47 OTHER INSTRUMENTATION↗

Image Quality Characteristics of Handheld Display Devices for Medical Imaging

Handheld devices such as mobile phones and tablet computers have become widespread with thousands of available software applications. Recently, handhelds are being proposed as part of medical imaging solutions, especially in emergency medicine, where immediate consultation is required. However, handheld devices differ significantly from medical workstation displays in terms of display characteristics. Moreover, the characteristics vary significantly among device types. We investigate the image quality characteristics of various handheld devices with respect to luminance response, spatial resolution, spatial noise, and reflectance. We show that the luminance characteristics of the handheld displays are different from those of workstation displays complying with grayscale standard target response suggesting that luminance calibration might be needed. Our results also demonstrate that the spatial characteristics of handhelds can surpass those of medical workstation displays particularly for recent generation devices. While a 5 mega-pixel monochrome workstation display has horizontal and vertical modulation transfer factors of 0.52 and 0.47 at the Nyquist frequency, the handheld displays released after 2011 can have values higher than 0.63 at the respective Nyquist frequencies. The noise power spectra for workstation displays are higher than 1.2x10 -5 mm 2 at 1 mm -1 , while handheld displays have values lower than 3.7x10 -6 mm 2 . Reflectance measurements on some of the handheld displays are consistent with measurements for workstation displays with, in some cases, low specular and diffuse reflectance coefficients. The variability of the characterization results among devices due to the different technological features indicates that image quality varies greatly among handheld display devices.

47 OTHER INSTRUMENTATION↗

Direct electron beam patterning of electro-optically active PEDOT:PSS

The optical and electronic tunability of the conductive polymer poly(3,4-ethylenedioxythiophene):poly(styrene sulfonate) (PEDOT:PSS) has enabled emerging applications as diverse as bioelectronics, flexible electronics, and micro- and nano-photonics. High-resolution spatial patterning of PEDOT:PSS opens up opportunities for novel active devices in a range of fields. However, typical lithographic processes require tedious indirect patterning and dry etch processes, while solution-processing methods such as ink-jet printing have limited spatial resolution. Here, we report a method for direct write nano-patterning of commercially available PEDOT:PSS through electron-beam induced solubility modulation. The written structures are water stable and maintain the conductivity as well as electrochemical and optical properties of PEDOT:PSS, highlighting the broad utility of our method. We demonstrate the potential of our strategy by preparing prototypical nano-wire structures with feature sizes down to 250 nm, an order of magnitude finer than previously reported direct write methods, opening the possibility of writing chip-scale microelectronic and optical devices. We finally use the high-resolution writing capabilities to fabricate electrically-switchable optical diffraction gratings. We show active switching in this archetypal system with >95 % contrast at CMOS-compatible voltages of +2 V and -3 V, offering a route towards highly-miniaturized dynamic optoelectronic devices.

42 ENGINEERING↗

IDAES GTEP 0.1 Release

The Institute for the Design of Advanced Energy Systems (IDAES) Generation and Transmission Expansion Planning (GTEP) package provides a Pyomo-based implementation of a modular, flexible, Generalized Disjunctive Programming (GDP) formulation for power infrastructure planning problems. This package is designed with the following goals in mind: - Abstract GTEP modeling away from any particular case study or fixed modeling assumptions (e.g., technologies, temporal resolution, spatial resolution, policy implications, etc.) - Admit flexible decision sets and heterogeneous parameterization - Allow high-level modeling options to be understood easily, chosen modularly, and changed rapidly

AS↗

Requirements for space shuttle scatter radar experiments

The feasibility of carrying out scatter radar experiments on the space shuttle was analyzed. Design criteria considered were the required average transmitter power, frequency resolution, spatial resolution, and statistical accuracy. Experiments analyzed were measurement of the naturally enhanced plasma line and the ion component of the incoherent scatter spectrum, and the plasma line artificially enhanced by an intense HF radio wave. The ion component measurement does not appear feasible, while the other two appear reasonable for short ranges only.

Harker, K. J.↗

Requirements for Space Shuttle incoherent scatter experiments

The feasibility of carrying out incoherent-scatter experiments on the Space Shuttle has been analyzed. Design criteria considered were the required average transmitter power, frequency resolution, spatial resolution, and statistical accuracy. Experiments analyzed were measurement of the naturally enhanced plasma line and the ion component of the incoherent-scatter spectrum, as well as the plasma line artificially enhanced by an intense HF radiowave. The ion-component measurement does not appear feasible, while the other two appear reasonable for short ranges only.

Harker, K. J.↗

Construction and evaluation of an imaging focussed-mesh electron multiplier for space instrumentation

A focused-mesh electron multiplier (FMEM) has been combined with a wedge and strip position-sensitive anode to create a novel detector that is considered likely to have a number of applications in space astronomy and laboratory image sensing. Results from the first application of a wedge and strip anode to an FMEM are presented including spatial resolution, spatial linearity, background rate, and pulse risetime. The converted multiplier retains the attributes of an FMEM that made it attractive in the first place, such as low background, high speed, and high dynamic range.

Vallerga, J.↗

Air Quality Forecasting at Sub-City Scale by Combining Models, Satellites, and Surface Measures

While there are a variety of sources for air quality information, no one source simultaneously allows for high accuracy, low bias, fine spatial resolution, wide spatial coverage, high temporal frequency, and the capability for near-term forecasting of air quality. Global models, like the NASA’s Goddard Earth Observing System -Composition Forecasting (GEOS-CF) model, provide global coverage and forecasting capabilities, but operate at relatively coarse spatial resolution and require ground-truthing with in-situ data. Polar-orbiting satellite data products, like those of the ESA TROPOspheric Monitoring Instrument (TROPOMI), provide higher-spatial-resolution remote sensing of atmospheric composition, but are limited by cloud cover and overpass times and report column-integrated quantities. Surface measurements, both from regulatory-grade monitors and low-cost networks, measure “nose-level” air quality, but may not represent concentration variability across large spatial domains, and (in the case of low-cost sensors) are subject to interference and biases. There exists a great potential to combine these diverse data sources together, using the strengths of some to offset the weaknesses of others to build a more comprehensive picture of air quality. This presentation will summarize results from ongoing efforts to produce such a combined forecast, with application case studies for surface-level Nitrogen Dioxide forecasting in several major US cities. Furthermore, we will examine the relative impacts and benefits of different data sources on the forecasting accuracy at different spatial and temporal scales. Finally, we will examine the potential for integrating low-cost sensors into such a system, both in terms of using these integrated air quality estimates as a baseline from which to calibrate networks of low-cost sensors in the field, and in terms of using dense networks of low-cost sensors to refine the spatial resolution of integrated air quality forecasts.

Air Quality↗

Characterization of Pixelated Cadmium-Zinc-Telluride Detectors for Astrophysical Applications

Comparisons of charge sharing and charge loss measurements between two pixelated Cadmium-Zinc-Telluride (CdZnTe) detectors are discussed. These properties along with the detector geometry help to define the limiting energy resolution and spatial resolution of the detector in question. The first detector consists of a 1-mm-thick piece of CdZnTe sputtered with a 4x4 array of pixels with pixel pitch of 750 microns (inter-pixel gap is 100 microns). Signal readout is via discrete ultra-low-noise preamplifiers, one for each of the 16 pixels. The second detector consists of a 2-mm-thick piece of CdZnTe sputtered with a 16x16 array of pixels with a pixel pitch of 300 microns (inter-pixel gap is 50 microns). This crystal is bonded to a custom-built readout chip (ASIC) providing all front-end electronics to each of the 256 independent pixels. These detectors act as precursors to that which will be used at the focal plane of the High Energy Replicated Optics (HERO) telescope currently being developed at Marshall Space Flight Center. With a telescope focal length of 6 meters, the detector needs to have a spatial resolution of around 200 microns in order to take full advantage of the HERO angular resolution. We discuss to what degree charge sharing will degrade energy resolution but will improve our spatial resolution through position interpolation.

Gaskin, Jessica↗

Spatial-Spectral Representation for X-Ray Fluorescence Image Super-Resolution

X-ray fluorescence (XRF) scanning of works of art is becoming an increasing popular nondestructive analyticalmethod. The high quality XRF spectra is necessary to obtain significant information on both major and minor elements used for characterization and provenance analysis. However, there is a tradeoff between the spatial resolution of an XRF scan and the signalto- noise ratio (SNR) of each pixel’s spectrum, due to the limited scanning time. In this project, we propose an XRF image super-resolution method to address this tradeoff; thus, obtaining a high spatial resolution XRF scan with high SNR. We fuse a lowresolution XRF image and a conventional RGB high-resolution image into a product of both high spatial and high spectral resolution XRF image. There is no guarantee of a one to one mapping between XRF spectrum and RGB color since, for instance, paintings with hidden layers cannot be detected in visible but can in X-ray wavelengths. We separate the XRF image into the visible and nonvisible components. The spatial resolution of the visible component is increased utilizing the high-resolution RGB image, whereas the spatial resolution of the non-visible component is increased using a total variation super-resolution method. Finally, the visible and nonvisible components are combined to obtain the final result.

Dai, Qiqin↗

Effects of reflector and crystal surface on the performance of a depth-encoding PET detector with dual-ended readout

Purpose: Depth encoding detectors are required to improve the spatial resolution and spatial resolution uniformity of small animal positron emission tomography (PET) scanners, as well as dedicated breast and brain scanners. Depth of interaction (DOI) can be measured by using dual-ended readout of lutetium oxyorthosilicate (LSO) scintillator arrays with position-sensitive avalanche photodiodes. Inter-crystal reflectors and crystal surface treatments play important roles in determining the performance of dual-ended detectors. In this paper, the authors evaluated five LSO arrays made with three different intercrystal reflectors and with either polished or unpolished crystal surfaces. Methods: The crystal size in all arrays was 1.5 mm, which is typical of the detector size used in small animal and dedicated breast scanners. The LSO arrays were measured with dual-ended readout and were compared in terms of flood histogram, energy resolution, and DOI resolution performance. Results: The four arrays using enhanced specular reflector (ESR) and Toray reflector provided similar quality flood histograms and the array using Crystal Wrap reflector gave the worst flood histogram. The two arrays using ESR reflector provided the best energy resolution and the array using Crystal Wrap reflector yielded the worst energy resolution. All arrays except the polished ESR array provided good DOI resolution ranging from 1.9 mm to 2.9 mm. DOI resolution improved as the gradient in light collection efficiency with depth (GLCED) increased. The geometric mean energies were also calculated for these dual-ended readout detectors as an alternative to the conventional summed total energy. It was shown that the geometric mean energy is advantageous in that it provides more uniform photopeak amplitude at different depths for arrays with high GLCED, and is beneficial in event selection by allowing a fixed energy window independent of depth. A new method of DOI calculation that improved the linearity of DOI ratio vs depth and simplifies the DOI calibration procedure also was developed and tested. Conclusions: The results of these studies provide useful guidance in selecting the proper reflectors and crystal surface treatments when LSO arrays are used for high-resolution PET applications in small animal scanners or dedicated breast and brain scanners.

60 APPLIED LIFE SCIENCES↗