Search NASA⌕ Search

SEARCH · Search NASA

Results for “spectral error”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

Pixel Based Model For High Latitude Dust Detection

Current methods of dust detection rely on spectral sensitivity at visible (RGB) and infrared wavelengths. However, their application on different regions needs to be tuned to mitigate errors associated with background properties. High latitude dust (HLD) regions are characterized by surface with variable albedos and land cover, thus further complicating the dust detection. Leveraging supervised machine learning (ML) methods, we propose a new method accounting for regional differences of dust occurrence.

High latitude dust↗

The Effect of Spectral Resolution of Light Sources on Photopic and a-opic Quantities

There is a growing interest in including light source spectrum in advanced lighting software tools and simulations. Given that traditional lighting software tools have been used primarily for calculating photometric quantities, their simplifying assumptions may not be suitable for calculating other a-opic quantities. Commonly used simulation tools use three values to represent the three primary colors (red, green, and blue), but others have expanded the number of bands (i.e., the spectral resolution) to 9, 27, or 81 in an attempt to more accurately represent variations in light source spectrum and downstream spectrally-derived quantities. It remains unclear, however, to what extent spectral resolution affects calculated quantities. To address this gap, a numerical analysis was completed using a large spectral power distribution database (n = 1,302 light sources). Calculated illuminance, a-opic irradiance, luminous efficacy of radiation (LER), melanopic efficacy of radiation (MER), and melanopic to photopic (M/P) ratio were compared for spectral resolutions of 3 and 9 bands compared to a baseline of 81 bands. Across all examined lighting quantities, considerable errors—a mean absolute percent error of 18.4%—were found when using 3 band calculations. These were reduced to 4% for 9 band calculations. The errors varied by metric and light source type. The results suggest that the use of 9 bands can more accurately characterize performance of different light source types across a range of metrics compared to using 3 bands.

Abboushi, Belal K.↗

Intrastep, Stage-Value Predictors for Diagonally-Implicit Runge-Kutta Methods

To better identify the necessary attributes of good stage-value predictors (SVPs), numerous SVPs are designed for an existing: ESDIRK4(3)7L[2]SA [26] and a new: ESDIRK4(3)8L[2]SA scheme.1 Both are stifflyaccurate, stage-order two, explicit, singly-diagonally implicit Runge–Kutta (ESDIRK) schemes. Tradeoffs are studied in the parameter spaces enforcing the constraints on accuracy, linear stability, nonlinear stability and coefficient size to determine which objectives correlate with effective predictors. The SVPs are tested on three challenging external aerodynamics problems [107 − 108 degrees of freedom (DoFs)], each with a different level of stiffness. The problems include two 3D airfoils simulations and one canonical turbulence simulation. All simulations use the compressible Navier-Stokes equations (CNSE). An entropy stable spectral collocation formulation is used for discretizing the spatial terms in the equations. Simulations are performed at a wide variety of temporal error tolerances. Problems that are sufficiently stiff (e.g., lax temporal error tolerances) benefit from SVPs designed with second-order accuracy and stability properties: A-stability, and L-stability, rather than high accuracy constraints. Simulations with modest stiffness (e.g., strict error tolerances) are better suited for SVPs designed using high accuracy constraints. Designing SVPs with enhanced stability properties is tedious but worthwhile. Simulation times are reduced with optimal SVPs by as much as 100% on some stages, with combined stepwise improvements of between 50 − 100% for both methods. A comparative study is performed with the two aforementioned methods as well as four other ESDIRKs. The newly designed ESDIRK4(3)8L[2]SA with γ ≈ 1/10, proves to be the most efficient of the six tested ESDIRK schemes simulating the CNSE.

Diagonally-Implicit Runge-Kutta↗

CLARREO: Reference Inter-Calibration on Orbit With Reflected Solar Spectrometer

The CLARREO approach for reference intercalibration is based on obtaining coincident highly accurate spectral reflectance and reflected radiance measurements, and establish an on-orbit reference for existing Earth viewing reflected solar radiation sensors: CERES and VIIRS on JPSS satellites, AVHRR and follow-on imagers on MetOp, and imagers on GEO platforms. The mission goal is to be able to provide CLARREO RS reference observations that are matched in space, time, and viewing angles with measurements from the aforementioned instruments, with sampling sufficient to overcome the random error sources from imperfect data matching and instrument noise. The intercalibration method is to monitor over time changes in targeted sensor response function parameters: effective offset, gain, nonlinearity, spectral degradation, and sensitivity to polarization of optics.

Lukashin, C.↗

Optimization of the Multi-Spectral Euclidean Distance Calculation for FPGA-based Spaceborne Systems

Due to the high quantity of operations that spaceborne processing systems must carry out in space, new methodologies and techniques are being presented as good alternatives in order to free the main processor from work and improve the overall performance. These include the development of ancillary dedicated hardware circuits that carry out the more redundant and computationally expensive operations in a faster way, leaving the main processor free to carry out other tasks while waiting for the result. One of these devices is SpaceCube, a FPGA-based system designed by NASA. The opportunity to use FPGA reconfigurable architectures in space allows not only the optimization of the mission operations with hardware-level solutions, but also the ability to create new and improved versions of the circuits, including error corrections, once the satellite is already in orbit. In this work, we propose the optimization of a common operation in remote sensing: the Multi-Spectral Euclidean Distance calculation. For that, two different hardware architectures have been designed and implemented in a Xilinx Virtex-5 FPGA, the same model of FPGAs used by SpaceCube. Previous results have shown that the communications between the embedded processor and the circuit create a bottleneck that affects the overall performance in a negative way. In order to avoid this, advanced methods including memory sharing, Native Port Interface (NPI) connections and Data Burst Transfers have been used.

Cristo, Alejandro↗

Preliminary estimates of radiosonde thermistor errors

It has been long realized that radiosonde temperature measurements are subject to errors, not the least of which is the effect of long- and short-wave radiation. Methods of adjusting the daytime temperatures to a nighttime equivalent temperature were developed a number of years ago, and are used by some analysis centers. Other than providing consistent observations for analysis this procedure does not provide a true correction. The literature discusses the problem of radiosonde temperature errors but it is not apparent what effort, if any, has been taken to quantify these errors. In order to quantify this radiation error, radiosondes containing multiple thermistors with different coatings were flown at Goddard Space Flight Center/Wallops Flight Facility. The coatings employed had different spectral characteristics and, therefore, different absorption and emissivity properties. Discrimination of the recorded temperatures enabled day and night correction values to be determined for the US standard white-coated rod thermistor. The correction magnitudes are given and a comparison of US measured temperatures before and after correction are compared with temperatures measured with the Vaisala radiosonde. The US and Vaisala radiosonde data are from the recently completed WMO International Radiosonde Intercomparison held at Wallops. The corrections are in the proper direction, day and night, and reduce day-night temperature differences to less than 0,5°C between surface and 30 hPa. The present uncorrected temperatures used with the Viz radiosonde have day-night differences that exceed 1°C at levels below 90 hPa. Additional measurements are planned to confirm these preliminary results and determine the solar elevation angle effect on the corrections. The technique used to obtain the corrections may also be used to recover a true 'absolute' value and might be considered a valuable contribution to the meteorological community for use as a reference instrument.

Temperature measurement↗

A new spectrally-invariant approach to the remote sensing of inhomogeneous clouds

Current operational satellite retrievals of cloud optical and microphysical properties go back to the Nakajima-King technique developed at the end of the 1980s. This technique is based on library calculations for plane-parallel homogeneous clouds. It often works well for overcast skies but leads to substantial errors for inhomogeneous and broken cloud fields where the plane-parallel-geometry assumption is no longer valid. The basic concept of a new technique was first introduced in nuclear physics to quantify the critical conditions of reactors. Based on the eigenvalues of the radiative transfer equation, their approach provides a powerful means to parameterize the structure of 3D media. This parameterization was later successfully applied to relate surface reflectance spectra to 3D canopy structure and is known as the spectrally-invariant approximation. The proposed approach adapts this technique to the remote sensing of cloud properties such as droplet single scattering albedo and the average number of scatterings (which are the fundamental parameters in radiative transfer theory), with an emphasis on quantifying the associated errors and uncertainties. This retrieval is free from the plane-parallel homogeneous cloud assumption.

clouds↗

The solar spectral irradiance 1200-3184 A near solar maximum - July 15, 1980

Results of a sounding rocket program designed to measure the total solar ultraviolet input to the upper atmosphere are presented. Two spectrometers, a far-ultraviolet (FUV) to cover 1160-1850 A, and a middle ultraviolet (MUV) to cover 1600-3184 A, were launched piggy-back on a Black Brant rocket to an altitude of 325 km on 7-15-1980. Tables of the detailed error budgets of the reclaimed instruments are provided. Comparisons are made with results of a 1979 flight, and of 1979 and 1980 flights with solar minimum results of Rottman (1981), and reveal significant solar spectral irradiance variability from solar minimum to maximum. MUV readings below 2100 A were 14% higher in 1980 and 14% lower in 1979 than Rottman's data, and it is concluded that a significant variability occurred at wavelengths less than 1800 A.

Mount, G. H.↗

Overview of oxygen opacity experiments at the National Ignition Facility and investigation of potential systematic errors

Experiments to measure oxygen opacity at stellar interior conditions have been performed at the National Ignition Facility in a Discovery Science campaign. These experiments utilize the Opacity-on-NIF platform with a sample comprised of O, Mg, and Si. The spectral data from the Opacity Spectrometer cover the 1000–2000 eV photon energy range showing bound-free continuum absorption from O and line absorption from Mg and Si. DANTE and the Gated X-ray Detector are employed to measure the sample plasma’s temperature and density, respectively. Initial data show lower transmission than expected by theoretical models, raising questions of whether potential background or data uniformity concerns could produce systematic errors in the inferred transmission. Here, we investigate three concerns thought to be important for the oxygen opacity data, including instrumental scattered background, sample self-emission non-uniformity, and backlight continuum non-uniformity. Additionally, we show the effect of a recently developed method to account for 2nd order crystal reflection. The total effect of these concerns on one experiment is found to be small compared to the observed difference between the inferred transmission and a model calculation at the inferred temperature and density. Thus, we conclude that these potential sources of systematic error cannot account for the observed difference, increasing the likelihood of a real effect due to the high temperature and density conditions. However, because this is only a single experiment, we cannot make a firm conclusion. More experiments measuring the opacity and necessary calibrations are needed to assess the reproducibility and uncertainty of this result.

79 ASTRONOMY AND ASTROPHYSICS↗

Preliminary Comparisons of the Information Content and Utility of TM Versus MSS Data

Comparisons were made between subscenes from the first TM scene acquired of the Washington, D.C. area and a MSS scene acquired approximately one year earlier. Three types of analyses were conducted to compare TM and MSS data: a water body analysis, a principal components analysis and a spectral clustering analysis. The water body analysis compared the capability of the TM to the MSS for detecting small uniform targets. Of the 59 ponds located on aerial photographs 34 (58%) were detected by the TM with six commission errors (15%) and 13 (22%) were detected by the MSS with three commission errors (19%). The smallest water body detected by the TM was 16 meters; the smallest detected by the MSS was 40 meters. For the principal components analysis, means and covariance matrices were calculated for each subscene, and principal components images generated and characterized. In the spectral clustering comparison each scene was independently clustered and the clusters were assigned to informational classes. The preliminary comparison indicated that TM data provides enhancements over MSS in terms of (1) small target detection and (2) data dimensionality (even with 4-band data). The extra dimension, partially resultant from TM band 1, appears useful for built-up/non-built-up area separation.

Markham, B. L.↗

A spectral multi-domain technique with application to generalized curvilinear coordinates

Spectral collocation methods have proven to be efficient discretization schemes for many aerodynamic and fluid mechanic problems. The high order accuracy and resolution shown by these methods allows one to obtain engineering accuracy solutions on coarse meshes, or alternatively, to obtain solutions with very small error. One drawback to these techniques was the requirement that a complicated physical domain must map into a simple computational domain for discretization. This mapping must be smooth if the high order accuracy and expontential convergence rates associated with spectral methods are to be preserved. Additionally even smooth stretching transformations can decrease the accuracy of a spectral method, if the stretching is severe. A further difficulty with spectral methods was in their implementation on parallel processing computers, where efficient spectral algorithms were lacking. The above restrictions are overcome by splitting the domain into regions, each of which preserve the advantages of spectral collocation, and allow the ratio of the mesh spacing between regions to be several orders of magnitude higher than allowable in a single domain. Such stretchings would be required to resolve the thin viscous region in an external aerodynamic problem. Adjoining regions are interfaced by enforcing a global flux balance which preserves high-order continuity of the solution, regardless of the type of the equations being solved.

Macaraeg, M. G.↗

DANTE as a primary temperature diagnostic for the NIF iron opacity campaign

The Opacity Platform on the National Ignition Facility (NIF) has been developed to measure iron opacities at varying densities and temperatures relevant to the solar interior and to verify recent experimental results obtained at the Sandia Z-machine, that diverge from theory. The first set of NIF experiments collected iron opacity data at ∼150 eV to 160 eV and an electron density of ∼7 × 1021 cm−3, with a goal to study temperatures up to ∼210 eV, with electron densities of up to ∼3 × 1022 cm−3. Among several techniques used to infer the temperature of the heated Fe sample, the absolutely calibrated DANTE-2 filtered diode array routinely provides measurements of the hohlraum conditions near the sample. However, the DANTE-2 temperatures are consistently low compared to pre-shot LASNEX simulations for a range of laser drive energies. We have re-evaluated the estimated uncertainty in the reported DANTE-2 temperatures and also the error generated by varying channel participation in the data analysis. An uncertainty of ±5% or better can be achieved with appropriate spectral coverage, channel participation, and metrology of the viewing slot.

Opachich, Y. P. (ORCID:0000000314323989)↗

KilonovaNet : Surrogate models of kilonova spectra with conditional variational autoencoders

ABSTRACT Detailed radiative transfer simulations of kilonova spectra play an essential role in multimessenger astrophysics. Using the simulation results in parameter inference studies requires building a surrogate model from the simulation outputs to use in algorithms requiring sampling. In this work, we present kilonovanet, an implementation of conditional variational autoencoders (cVAEs) for the construction of surrogate models of kilonova spectra. This method can be trained on spectra directly, removing overhead time of pre-processing spectra, and greatly speeds up parameter inference time. We build surrogate models of three state-of-the-art kilonova simulation data sets and present in-depth surrogate error evaluation methods, which can in general be applied to any surrogate construction method. By creating synthetic photometric observations from the spectral surrogate, we perform parameter inference for the observed light-curve data of GW170817 and compare the results with previous analyses. Given the speed with which kilonovanet performs during parameter inference, it will serve as a useful tool in future gravitational wave observing runs to quickly analyse potential kilonova candidates.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Research on infrared astrophysics and X ray and XUV astronomy

The infrared research was divided into two related subjects, observations at wavelengths less than 34 microns and millimeter wavelength observations. A new complex of infrared sources in the Orion Nebula observed along with a broad range of galactic and extragalactic objects. The Comet Kohoutek was measured in the 1-20 micron wavelength region and its thermal properties agreed closely with those of Comet Ikeya-Seki. Combined infrared and photoelectric studies of the Makarian galaxies showed them to have a composite spectrum with a large emission feature in the far infrared. The development of one millimeter photometry and composited bolometers is described. A technique of reconstructing two dimensional surface brightness distributions with appropriate errors from individual strip scans was developed. Model parameters were determined by fitting data in non-linear systems. Results show spectral parameter uncertainties are underestimated or incorrectly evaluated in most studies.

Source record↗

A study of the effects of vertical resolution and measurement errors on an iteratively inverted temperature profile

A direct inversion method for inverting the temperature profile from satellite-measured radiation is discussed. The nth power of the weighting function in the integral radiative-transfer equation is used as the weight in the averaging process. The vertical resolution of the inverted temperature profile and the response of the inverted temperature profile to the measurement errors are examined in terms of n. It is found that for smaller values of n, the vertical resolution and the effect of measurement errors are reduced. When n = 0, both the vertical resolution and error effect are minimum. The temperature profile is adjusted by a constant; any structure different from the initial shape cannot be resolved. This is equivalent to the case where the entire atmosphere is treated as one layer with a fixed shape of temperature profile. When n approaches infinity, both the vertical resolution and error effect are maximum. This is equivalent to the case where the entire atmosphere is divided into m (the number of spectral channels) layers. Within each layer, the temperatures are adjusted by a constant, and any structure different from the initial shape cannot be resolved. Also, the shape of the final solution is closer to the initial profile if the value of n is smaller.

Chow, M.-D.↗

Specular reflectance of optical-black coatings in the far infrared

Far-infrared specular reflectance spectra of seven optically black coatings near normal incidence are presented. Seven photometric spectra were obtained using eleven bandpass transmission filters in the wavelength range between 12 and 500 microns, and three interferometric spectra were obtained for corroboration. Data on the construction, thickness, and rms surface roughness of the coatings are also presented. The chemical composition of three coatings can be distinguished from that of the others by a strong absorption feature between 20 and 40 microns, which can be largely attributed to amorphous silicate material. At 100 microns, the most and least reflective coatings differ by nearly 3 orders of magnitude. Inverse relationships observed between the spectra and the roughness and thickness of the coatings led to development of a reflecting-layer model for the measured reflectance. The model successfully describes the spectra at wavelengths outside the silicate absorption, and optical constants are deduced from a nonlinear least squares fit to the data. Parametric errors are estimated by chi-square analysis, and sensitivity tests are performed to determine which parameters control reflectance in different spectral regions.

Smith, S. M.↗

SO2 absorption cross sections in the near U.V.

In order to understand data measured by the TOMS instrument on Nimbus 7 after the eruption of El Chichon, absorption cross sections are measured in SO2 between 3000 and 3240 A at 295 and 210 K. Errors for these measurements range from less than 2 percent to about 10 percent. Measurements in the 3175 + or 5 A spectral region observed by TOMS indicate that there is a 9 percent reduction in the average cross section at 210 K compared to room-temperature data. Peak cross sections measured at low temperature show increases up to 20 percent over room-temperature data, while cross-section decreases are measured at low temperatures in the areas between the strong features.

Mcgee, Thomas J.↗

Low pressure gas flow analysis through an effusive inlet using mass spectrometry

A mass spectrometric method for analyzing flow past and through an effusive inlet designed for use on the tethered satellite and other entering vehicles is discussed. Source stream concentrations of species in a gaseous mixture are determined using a calibration of measured mass spectral intensities versus source stream pressure for standard gas mixtures and pure gases. Concentrations are shown to be accurate within experimental error. Theoretical explanations for observed mass discrimination effects as they relate to the various flow situations in the effusive inlet and the experimental apparatus are discussed.

Brown, David R.↗