Search NASA⌕ Search

SEARCH · Search NASA

Results for “spectrographs”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

HST/STIS Spectroscopy of the Local Lyman-Alpha Forest

The Space Telescope Imaging Spectrograph (STIS) aboard the Hubble Space Telescope has brought a new era in studying the low-redshift Lyman-alpha Forest. The advantages of STIS over previous HST spectrographs include:(l) a high spectral resolution (7 km/s) comparable to Keck/HIRES spectra of the high-redshift Lyman-alpha forest; (2) a high observing efficiency brought about by an imaging detector able to span the full fares wavelength range (1150-1700 A, or equivalently, z=0.0-0.4) in a single exposure. The STIS Investigation Definition Team is therefore conducting an observational program to determine the properties of the low-redshift intergalactic medium as manifested by the Lyman-alpha forest. The team has made observations of the quasars: 3C 273, 3C 351, and PKS 0405. We shall present results based on the sightline to 3C 273, the brightest of these sources.

Heap, Sara R.↗

The AstroBiology Explorer (ABE) MIDEX Mission Concept

The Astrobiology Explorer (ABE) is a MIDEX mission concept under study at NASA's Ames Research Center in collaboration with Ball Aerospace & Technologies, Corp. ABE will conduct IR spectroscopic observations to address important problems in astrobiology, astrochemistry, and astrophysics. The core observational program would make fundamental scientific progress in understanding the distribution, identity, and evolution of ices and organic matter in dense molecular clouds, young forming stellar systems, stellar outflows, the general diffuse ISM, HII regions, Solar System bodies, and external galaxies. The ABE instrument concept includes a 0.6 m aperture Cassegrain telescope and two moderate resolution (R = 2000-3000) spectrographs covering the 2.5-16 micron spectral region. Large format (1024x 1024 pixel or larger) IR detector arrays and bandpass filters will allow each spectrograph to cover an entire octave of spectral range or more per exposure without any moving parts. The telescope will be cooled below 50K by a cryogenic dewar shielded by a sunshade. The detectors will be cooled to approximately 8K. The optimum orbital configuration for achieving the scientific objectives of the ABE mission is a low background, 1 AU Earth driftaway orbit requiring a Delta II launch vehicle. This configuration provides a low thermal background and allows adequate communications bandwidth and good access to the entire sky over the approximate 1-2 year mission lifetime.

Ennico, Kimberly↗

Deuterium Abundance Toward G191-B2B: Results from the Far Ultraviolet Spectroscopic Explorer (FUSE) Mission

High-resolution spectra of the hot white dwarf G191-B2B covering the wavelength region 905-1187A were obtained with the Far Ultraviolet Spectroscopic Explorer (FUSE). This data was used in conjunction with existing high-resolution Hubble Space Telescope STIS observations to evaluate the total H(sub I), D(sub I), O(sub I) and N(sub I) column densities along the line of sight. Previous determinations of N(D(sub I)) based upon GHRS (Goddard High Resolution Spectrograph) and STIS (Space Telescope Imaging Spectrograph) observations were controversial due to the saturated strength of the D(sub I) Lyman alpha line. In the present analysis the column density of D(sub I) has been measured using only the unsaturated Lyman beta and Lyman gamma lines observed by FUSE. A careful inspection of possible systematic uncertainties tied to the modeling of the stellar continuum or to the uncertainties in the FUSE instrumental character series has been performed. The column densities derived are: log N(D(sub I)) = 13.40+/-0.07, log N(O(sub I)) = 14.86+/-0.07, and log N(N(sub I)) = 13.87+/-0.07 quoted with 2sigma, uncertainties. The measurement of the H(sub I) column density by profile fitting of the Lyman alpha line has been found to be unsecure. If additional weak hot interstellar components are added to the three detected clouds along the line of sight, the H(sub I)) column density can be reduced quite significantly, even though the signal-to-noise ratio and spectral resolution at Lyman alpha are excellent. The new estimate of N(H(sub I)) toward G191-B2B reads: logN(H (sub I)) = 18.18+/-0.18 (2sigma uncertainty), so that the average (D/H) ratio on the line of sight is: (D/H)= 1.66(+0.9/-0.6) x 10(exp -5) (2sigma uncertainty).

Lemoine, M.↗

Toroidal Varied-Line Space (TVLS) Gratings

It is a particular challenge to develop a stigmatic spectrograph for XUV wavelengths since the very low normal-incidence reflectance of standard materials most often requires that the design be restricted to a single optical element which must simultaneously provide both re-imaging and spectral dispersion. This problem has been solved in the past by the use of toroidal gratings with uniform line-spaced rulings (TULS). A number of solar EUV (Extreme Ultraviolet) spectrometers have been based on such designs, including SOHO/CDS, Solar-B/EIS, and the sounding rockets SERTS and EUNIS. More recently, Kita, Harada, and collaborators have developed the theory of spherical gratings with varied line-space rulings (SVLS) operated at unity magnification, which have been flown on several astronomical satellite missions. We now combine these ideas into a spectrometer concept that puts varied-line space rulings onto toroidal gratings. Such TVLS designs are found to provide excellent imaging even at very large spectrograph magnifications and beam-speeds, permitting extremely high-quality performance in remarkably compact instrument packages. Optical characteristics of two solar spectrometers based on this concept are described: SUMI, proposed as a sounding rocket experiment, and NEXUS, proposed for the Solar Dynamics Observatory mission.

Thomas, Roger J.↗

Multiple Velocity Components in the C IV Absorption Line of NGC 5548

We have observed the much-studied Seyfert 1 galaxy NGC 5548 with the Goddard High-Resolution Spectrograph (GHRS) on the Hubble Space Telescope (HST). Our 14 ks observation covers the C IV emission line at a resolution of greater than 20,000. Our purpose was to study the absorption line found at lower resolution by IUE and the HST Faint Object Spectrograph. We found that the C IV absorption line resolves into six separate doublets with equivalent widths of 0.07-0.38 Angstrom. The absorption lines have blueshifts relative to the systemic velocity of the galaxy of 380-1250 km s(exp -1), except for one, which has a redshift of 250 km s(exp -1), suggesting both inflow and outflow. The inflowing component may be related to the accretion flow into the nuclear black hole. All the doublet lines are resolved by the GHRS. Three doublets are narrow, with FWHM greater than or approximately 100 km s(exp -1), and three are broad, FWHM approximately 160-290 km s(exp -1). We find evidence of partial covering by the narrow absorption lines. Either (but not both) of the two strongest broad doublets could be from the same material that produces the X-ray ionized absorber seen in soft X-rays. The remaining five systems must be at least 10 times less ionized (and so of lower total column density) to remain consistent with the X-ray spectra.

Mathur, Smita↗

Simultaneous UV and X-ray Spectroscopy of the Seyfert 1 Galaxy NGC 5548. I: Physical Conditions in the UV Absorbers

We present new UV spectra of the nucleus of the Seyfert 1 galaxy NGC 5548, which we obtained with the Space Telescope Imaging Spectrograph at high spectral resolution, in conjunction with simultaneous Chandra X-ray Observatory spectra. Taking advantage of the low UV continuum and broad emission-line fluxes, we have determined that the deepest UV absorption component covers at least a portion of the inner, high-ionization narrow-line region (NLR). We find nonunity covering factors in the cores of several kinematic components, which increase the column density measurements of N V and C IV by factors of 1.2 to 1.9 over the full-covering case; however, the revised columns have only a minor effect on the parameters derived from our photoionization models. For the first time, we have simultaneous N V and C IV columns for component 1 (at -1040 km/s), and find that this component cannot be an X-ray warm absorber, contrary to our previous claim based on nonsimultaneous observations. We find that models of the absorbers based on solar abundances severely overpredict the O VI columns previously obtained with the Far Ultraviolet Spectrograph, and present arguments that this is not likely due to variability. However, models that include either enhanced nitrogen (twice solar) or dust, with strong depletion of carbon in either case, are successful in matching all of the observed ionic columns. These models result in substantially lower ionization parameters and total column densities compared to dust-free solar-abundance models, and produce little O VII or O VIII, indicating that none of the UV absorbers are X-ray warm absorbers.

Crenshaw, D. M.↗

The Mars Microbeam Raman Spectrometer: An Improved Advanced Brassboard

An advanced brassboard (ADBB) of the Mars Miscrobeam Raman Spectrometer is being developed. The probe and spectrograph have been redesigned with improved optics and the electronics have been miniaturized. The modified optical design in the probe and spectrograph provides better spectral resolution than the previous model and enables the probe design to be more compatible with robotic arm deployment. The CCD detector is now cooled thermoelectrically in anticipation of eventual terrestrial field testing of the instrument.

Haskin, L. A.↗

The Star Formation History of Orion and its Environs

During this period of performance, we have obtained the following observations and carried out the analysis of the Orion associations itemized below. 1. Quest Optical Photometry: The photometric survey carries out with the Quest camera is finished. The strips at declinations +1 degree and -1 degree have already been processed. Photometry for a total of around 400,000 stars was obtained in these two strips with the Quest camera pipeline. Around 24,000 variables were picked out of this total by our variability software. Of these, around 2,500 stars fall above the main sequence and so were picked as candidates for spectroscopic follow-up. 2. Slit spectroscopy of bright candidates: Spectra for some 800 candidate PMS stars were obtained with the FAST spectrograph at the SAO 1.5m telescope in Mt. Hopkins. The spectra are being analyzed; 300 stars have been confirmed as young. 3. Multifiber spectroscopy: The first test of the multifiber spectrograph Hectoechelle were carried out in December 2003. One field of the Orion Nebula Cluster was observed with Hectochelle at three wavelength settings. A total of 157 spectra were obtained. Of these, 63 stars have been confirmed as Classical T Tauri stars, and 36 additional stars need further follow up. A paper is in preparation. 4. UBVRI photometry: We were granted time with the 4-shooter CCD Mosaic Camera at the SAO 1.2m telescope, to obtain UBVRI photometry of a subset of 53 newly identified T Tauri stars in the strips centered at DEC=-1 and +l. This sample is composed of strong Halpha emitting PMS stars (Classical T Tauri stars) located mostly in the Orion OB l b association, around the Orion Belt area. We have estimated mass accretion rates for 22 for these stars using the U photometry and the calibration of Gullbring et al. (1998), and found it to be similar to that of young stars in associations of similar age. 5. Near and mid-IR photometry: During the winter of 2003, we used the IR Camera on the SAO 1.2m telescope, to obtain L- band photometry of a set of the newly identified Orion OB l a and l b stars, in order to look for IR excess emission coming from the hotter inner parts of circumstellar disks. These data is being combined with the GEMINI/OSCIR 10 micron photometry obtained during 2002 and the mass accretion rates to determine the properties of disks in Ori lb. A paper is presently on preparation.

Calvet, Nuria↗

Variable Intrinsic UV Absorption in the Seyfert 1.5 Galaxy NGC 3516

We have examined the physical conditions in the intrinsic UV absorbing gas in the Seyfert 1.5 galaxy NGC 3516, using echelle spectra obtained with the Space Telescope Imaging Spectrograph aboard the Hubble Space Telescope on 2000 October 1. We confirm the presence of the 4 kinematic components detected in earlier Goddard High Resolution Spectrograph (GHRS) spectra, as well as 4 new absorption features with radial velocities ranging from -692 to -1372 kilometers per second. The C IV column densities of components 3 and 4 appear to have increased significantly compared to the GHRS epoch. Based on photoionization modeling and our analysis of contemporaneous Chandra X-ray Observatory spectra, we argue that these changes are in response to the drop in ionizing flux.

Kraemer, S. B.↗

WaFIRS, a Waveguide Far-IR Spectrometer: Enabling Space-Borne Spectroscopy of High-z Galaxies in the Far-IR and Submm

The discovery of galaxies beyond z approximately equal to 1 which emit the bulk of their luminosity at long wavelengths has demonstrated the need for high sensitivity, broadband spectroscopy in the far-IR/submm/mm bands. Because many of these sources are not detectable in the optical, long wavelength spectroscopy is key to measuring their redshifts and ISM conditions. The continuum source list will increase in the next decade with new ground-based instruments (SCUBA2, Bolocam, MAMBO) and the surveys of HSO and SIRTF. Yet the planned spectroscopic capabilities lag behind, primarily due to the difficulty in scaling existing IR spectrograph designs to longer wavelengths. To overcome these limitations, we are developing WaFIRS, a novel concept for long-wavelength spectroscopy which utilizes a parallel-plate waveguide and a curved diffraction grating. WaFIRS provides the large (approximately 60%) instantaneous bandwidth and high throughput of a conventional grating system, but offers a dramatic reduction in volume and mass. WaFIRS requires no space overheads for extra optical elements beyond the diffraction grating itself, and is two-dimensional because the propagation is confined between two parallel plates. Thus several modules could be stacked to multiplex either spatially or in different frequency bands. The size and mass savings provide opportunities for spectroscopy from space-borne observatories which would be impractical with conventional spectrographs. With background-limited detectors and a cooled 3.5 telescope, the line sensitivity would be better than that of ALMA, with instantaneous broad-band coverage. We have built and tested a WaFIRS prototype for 1-1.6 mm, and are currently constructing Z-Spec, a 100 mK model to be used as a ground-based lambda/DELTAlambda approximately equal to 350 submillimeter galaxy redshift machine.

Bradford, C. M.↗

Microshutters Arrays for the JWST Near Infrared Spectrometer

The Near Infrared Spectrograph (NIRSpec) for the James Webb Space Telescope (JWST) is an essential instrument for measuring the number and density evolution of galaxies following the epoch of initial formation. The NIRSpec is a multi-object spectrograph, allowing simultaneous observation of more than 100 candidate high redshift galaxies. A critical element of the instrument is the programmable field selector, the Microshutter Array. The system consists of four 175 x 384 arrays of individually openable shutters, close packed on a 100 x 200 micron pitch, which allow selection of over 200 candidate objects over the 3 min x 3 min field of the NIRSpec. We will describe the development, production, and test of this critical element of the NIRSpec.

Moseley, Harvey↗

Rocket and Laboratory Studies in Astronomy

This report covers the period from March 1, 2001 to August 31, 2004. This grant was the continuation of NASA grant NAG5-5122 and supported the Johns Hopkins sounding rocket program that had its roots in the 1960s. The emphasis of this program has been the development of instrumentation for far-ultraviolet astronomy, the training of graduate students in all aspects of a space mission, and the application of these techniques to timely scientific problems. During this period we completed the fabrication of our new long-slit dual-order spectrograph (LIDOS), and successfully flew it on a Black Brant sounding rocket on December 16, 2003 (36.208 UG). The targets were the bright star gamma-Cassiopeiae and its surrounding reflection nebulae, IC 59 and IC 63. We also continued the analysis of the data from our previous flight to study the reflection nebula IC 405 (36.198 UG), which revealed a far-ultraviolet nebular scatter to stellar flux ratio that, contrary to expectations, rises steeply toward the blue. Verifying this result required extensive post-flight analysis and calibration of the Faint Object Telescope FOT) payload, which entailed measuring the telescope mirror reflectivities, the absolute efficiency of the spectrograph, and the telescope point spread function, using a new vacuum collimator developed as part of former graduate student Eric Burgh's Ph.D. dissertation. This work, being done with graduate student Kevin France, has been completed and a paper describing the results has been accepted for publication by the Astrophysical Journal. We have also continued a number of laboratory calibration studies and design efforts.

Feldman, Paul D.↗

A Program to Detect and Characterize Extra-Solar Giant Planets

The upgrade to the AFOE spectrograph at the 1.5-m Tillinghast telescope at FLWO Observatory, described in detail in the previous progress report, was completed. Work included installing a new CCD detector (using SA0 internal funds) to replace the previous detector, which had failed after many thermal cyclings during the previous nearly ten years of operation. The new detector (a back-illuminated Marconi 2K x 2K detector) shows excellent quantum efficiency, and employs dual readout channels to keep the readout time as short as 20 seconds. Tests of the attainable radial velocity precision of the upgraded spectrograph with the new detector show an improvement in radial velocity detection efficiency by a factor of about 10 over the previous AFOE configuration, allowing us to push the photon-noise-limited doppler precision of 7 m/s to correspondingly fainter stars. This work was carried out by Co-investigator Sylvain Korzennik, along with the late Peter Nisenson.

Lindstrim, David↗

Ultraviolet Views of Enceladus, Tethys, and Dione

The Cassini Ultraviolet Imaging Spectrograph (UVIS) has collected ultraviolet observations of many of Saturn's icy moons since Cassini's insertion into orbit around Saturn. We will report on results from Enceladus, Tethys and Dione, orbiting in the Saturn system at distances of 3.95, 4.88 and 6.26 Saturn radii, respectively. Icy satellite science objectives of the UVIS include investigations of surface age and evolution, surface composition and chemistry, and tenuous exospheres. We address these objectives by producing albedo maps, and reflection and emission spectra, and observing stellar occultations. UVIS has four channels: EUV: Extreme Ultraviolet (55 nm to 110 nm), FUV: Far Ultraviolet (110 to 190 nm), HSP: High Speed Photometer, and HDAC: Hydrogen-Deuterium Absorption Cell. The EUV and FUV spectrographs image onto a 2-dimensional detector, with 64 spatial rows by 1024 spectral columns. To-date we have focused primarily on the far ultraviolet data acquired with the low resolution slit width (4.8 angstrom spectral resolution). Additional information is included in the original extended abstract.

Hansen, C. J.↗

CO/H2 in Translucent Clouds

A thorough examination of techniques to improve the resolution of the FUSE spectrograph was undertaken. These involved co-adding time tagged data very carefully so as to remove any blurs caused by drift. In addition, data was binned by detector pulse height bin (to eliminate any positional vs. gain variations, e.g. "walk"). These techniques only resulted in an extremely modest increase in the spectral resolution, insufficient to allow the CO/H2 studies to be performed. The only remaining potential source of blur was defocus - implying the instrument was never properly focused on orbit. Private discussions with B.G. Anderson of the FUSE team resulted in my learning that this was in fact the case - the slidgrating distance was never optimized on orbit - resulting in a degradation of the peak performance of the instrument. Unfortunately, this was never publicized, even to myself, a member of the instrument tem and the spectrograph designer.

Green, James↗

Solar CIV Vacuum-Ultraviolet Fabry-Perot Interferometers

Aims: A tunable, high spectral resolution, high effective finesse, vacuum ultraviolet (VUV) Fabry-Perot interferometer (PPI) is designed for obtaining narrow-passband images, magnetograms, and Dopplergrams of the transition region emission line of CIV (155 nm). Methods: The integral part of the CIV narrow passband filter package (with a 2-10 pm FWHM) consists of a multiple etalon system composed of a tunable interferometer that provides high-spectral resolution and a static low-spectral resolution interferometer that allows a large effective free spectral range. The prefilter for the interferometers is provided by a set of four mirrors with dielectric high-reflective coatings. A tunable interferometer, a VUV piezoelectric-control etalon, has undergone testing using the surrogate F2 eximer laser line at 157 nm for the CIV line. We present the results of the tests with a description of the overall concept for a complete narrow-band CIV spectral filter. The static interferometer of the filter is envisioned as being hudt using a set of fixed MgF2 plates. The four-mirror prefilter is designed to have dielectric multilayer n-stacks employing the design concept used in the Ultraviolet Imager of NASA's Polar Spacecraft. A dual etalon system allows the effective free spectral range to be commensurate with the prefilter profile. With an additional etalon, a triple etalon system would allow a spectrographic resolution of 2 pm. The basic strategy has been to combine the expertise of spaceflight etalon manufacturing with VUV coating technology to build a VUV FPI which combines the best attributes of imagers and spectrographs into a single compact instrument. Results. Spectro-polarimetry observations of the transition region CIV emission can be performed to increase the understanding of the magnetic forces, mass motion, evolution, and energy release within the solar atmosphere at the base of the corona where most of the magnetic field is approximately force-free. The 2D imaging of the full vector magnetic field at the height of maximum magnetic influence (minimum plasma beta) can be accomplished, albeit difficult, by measuring the Zeeman splitting of the CIV resonance pair. Designs of multiple VUV FPIs can be developed for integration into future orbiting solar observatories to obtain rapid cadence, spectral imaging of the transition region.

Gary, G. Allen↗

The Homunculus: a Unique Astrophysical Laboratory

eta Car is surrounded by bipolar shells, the Homunculus and the internal Little Homunculus, that are observed in both emission and absorption. Thin disks, located between the bipolar lobes, include the very bright Weigelt blobs and the neutral emission structure called the Strontium filament. All are affected by changes in UV and X-Ray flux of the binary system. For example, the normally ionized Little Homunculus recombines during the few month long spectroscopic minimum and then reionizes. Spectral data, obtained with Hubble Space Telescope/Space Telescope Imaging Spectrograph (HST/STIS) and with Very Large Telescope/UltraViolet Echelle Spectrograph (VLT/UVES), provide a wealth of information on spectroscopic properties of neutral and singly-ionized metals and on chemistry of nitrogen rich, carbon, oxygen poor, dense, warm gas. This information is important to understand gamma ray bursters (GRB) that reveal red-shifted near-UV metallic absorptions from pre-GRB stellar ejecta.

Gull, T. R.↗

Remote Raman Sensor System for Testing of Rocks and Minerals

Recent and future explorations of Mars and lunar surfaces through rovers and landers have spawned great interest in developing an instrument that can perform in-situ analysis of minerals on planetary surfaces. Several research groups have anticipated that for such analysis, Raman spectroscopy is the best suited technique because it can unambiguously provide the composition and structure of a material. A remote pulsed Raman spectroscopy system for analyzing minerals was demonstrated at NASA Langley Research Center in collaboration with the University of Hawaii. This system utilizes a 532 nm pulsed laser as an excitation wavelength, and a telescope with a 4-inch aperture for collecting backscattered radiation. A spectrograph equipped with a super notch filter for attenuating Rayleigh scattering is used to analyze the scattered signal. To form the Raman spectrum, the spectrograph utilizes a holographic transmission grating that simultaneously disperses two spectral tracks on the detector for increased spectral range. The spectrum is recorded on an intensified charge-coupled device (ICCD) camera system, which provides high gain to allow detection of inherently weak Stokes lines. To evaluate the performance of the system, Raman standards such as calcite and naphthalene are analyzed. Several sets of rock and gemstone samples obtained from Ward s Natural Science are tested using the Raman spectroscopy system. In addition, Raman spectra of combustible substances such acetone and isopropanol are also obtained. Results obtained from those samples and combustible substances are presented.

Garcia, Christopher S.↗