Search NASA⌕ Search

SEARCH · Search NASA

Results for “storage capability”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

Marshall Space Flight Center Propulsion Systems Department (PSD) Knowledge Management (KM) Initiative

NASA Marshall Space Flight Center's Propulsion Systems Department (PSD) is four months into a fifteen month Knowledge Management (KM) initiative to support enhanced engineering decision making and analyses, faster resolution of anomalies (near-term) and effective, efficient knowledge infused engineering processes, reduced knowledge attrition, and reduced anomaly occurrences (long-term). The near-term objective of this initiative is developing a KM Pilot project, within the context of a 3-5 year KM strategy, to introduce and evaluate the use of KM within PSD. An internal NASA/MSFC PSD KM team was established early in project formulation to maintain a practitioner, user-centric focus throughout the conceptual development, planning and deployment of KM technologies and capabilities within the PSD. The PSD internal team is supported by the University of Alabama's Aging Infrastructure Systems Center of Excellence (AISCE), lntergraph Corporation, and The Knowledge Institute. The principle product of the initial four month effort has been strategic planning of PSD KNI implementation by first determining the "as is" state of KM capabilities and developing, planning and documenting the roadmap to achieve the desired "to be" state. Activities undertaken to suppo~th e planning phase have included data gathering; cultural surveys, group work-sessions, interviews, documentation review, and independent research. Assessments and analyses have beon pedormed including industry benchmarking, related local and Agency initiatives, specific tools and techniques used and strategies for leveraging existing resources, people and technology to achieve common KM goals. Key findings captured in the PSD KM Strategic Plan include the system vision, purpose, stakeholders, prioritized strategic objectives mapped to the top ten practitioner needs and analysis of current resource usage. Opportunities identified from research, analyses, cultural1KM surveys and practitioner interviews include: executive and senior management sponsorship, KM awareness, promotion and training, cultural change management, process improvement, leveraging existing resources and new innovative technologies to align with other NASA KM initiatives (convergence: the big picture). To enable results based incremental implementation and future growth of the KM initiative, key performance measures have been identified including stakeholder value, system utility, learning and growth (knowledge capture, sharing, reduced anomaly recurrence), cultural change, process improvement and return-on-investment. The next steps for the initial implementation spiral (focused on SSME Turbomachinery) have been identified, largely based on the organization and compilation of summary level engineering process models, data capture matrices, functional models and conceptual-level svstems architecture. Key elements include detailed KM requirements definition, KM technology architecture assessment, - evaluation and selection, deployable KM Pilot design, development, implementation and evaluation, and justifying full implementation (estimated Return-on-Investment). Features identified for the notional system architecture include the knowledge presentation layer (and its components), knowledge network layer (and its components), knowledge storage layer (and its components), User Interface and capabilities. This paper provides a snapshot of the progress to date, the near term planning for deploying the KM pilot project and a forward look at results based growth of KM capabilities with-in the MSFC PSD.

Caraccioli, Paul↗

Investigation of Fe-Ni Battery/Module for Grid Service Duty Cycles

Iron–nickel (Fe-Ni) batteries are renowned for their durability and resilience against overcharging and operating temperatures. However, they encounter challenges in achieving widespread adoption for energy storage applications due to their low efficiency and the need for regular maintenance and electrolyte replacement, which adds to maintenance costs. This study evaluates and demonstrates the capabilities of Fe-Ni batteries for participating in grid energy storage applications. Stable performance was observed frequency regulation (FR) testing at 100% and 50% state of charge (SOC)s, while at 50% SOC, there was a 14% increase in efficiency compared to 100% SOC. Although 25% SOC achieved higher efficiency, limited cyclability was observed due to reaching the discharge cutoff voltage. Optimal SOC selection, battery monitoring, maintenance, and appropriate charging strategies of Fe-Ni batteries seem to be crucial for their FR applications. Fe-Ni batteries exhibit stable peak shaving (PS) results, indicating their suitability and reliability under various load conditions for PS testing. Extended cycling tests confirm their potential for long-term grid-scale energy storage, enhancing their appeal for PS and FR applications.

25 ENERGY STORAGE↗

Report of the Artificial Gravity Panel

Tethers can be embodied into NASA's future space station development both as an experimental facility and as a technology for systems enhancement. Early action should be taken to ensure that the basic tether system be baselined into the initial space station architecture and that further concept studies be arranged to embody this basic capability. Space station tethered satellite operations would be continuous, subject to need and occasional association with local spacecraft operations in the proximity of the space station. The use of the tether principles would be further explored for attitude control and/or attitude stabilization damping, and proximity operations. For new tether uses, action should be taken to look at the tether for holding storage uses, proximity operations, and for extension of the capabilities of attached payloads systems. These applications should emphasize dynamic off-vertical tethers, rapid deployment, active-steered tethers, tether-boom combinations, and other concepts.

Butler, G.↗

Subcooling for Long Duration In-Space Cryogenic Propellant Storage

Cryogenic propellants such as hydrogen and oxygen are crucial for exploration of the solar system because of their superior specific impulse capability. Future missions may require vehicles to remain in space for months, necessitating long-term storage of these cryogens. A Thermodynamic Cryogen Subcooler (TCS) can ease the challenge of cryogenic fluid storage by removing energy from the cryogenic propellant through isobaric subcooling of the cryogen below its normal boiling point prior to launch. The isobaric subcooling of the cryogenic propellant will be performed by using a cold pressurant to maintain the tank pressure while the cryogen's temperature is simultaneously reduced using the TCS. The TCS hardware will be integrated into the launch infrastructure and there will be no significant addition to the launched dry mass. Heat leaks into all cryogenic propellant tanks, despite the use of the best insulation systems. However, the large heat capacity available in the subcooled cryogenic propellants allows the energy that leaks into the tank to be absorbed until the cryogen reaches its operational thermodynamic condition. During this period of heating of the subcooled cryogen there will be minimal loss of the propellant due to venting for pressure control. This simple technique can extend the operational life of a spacecraft or an orbital cryogenic depot for months with minimal mass penalty. In fact isobaric subcooling can more than double the in-space hold time of liquid hydrogen compared to normal boiling point hydrogen. A TCS for cryogenic propellants would thus provide an enhanced level of mission flexibility. Advances in the important components of the TCS will be discussed in this paper.

Mustafi, Shuvo↗

Automation of electromagnetic compatability (EMC) test facilities

Efforts to automate electromagnetic compatibility (EMC) test facilities at Marshall Space Flight Center are discussed. The present facility is used to accomplish a battery of nine standard tests (with limited variations) deigned to certify EMC of Shuttle payload equipment. Prior to this project, some EMC tests were partially automated, but others were performed manually. Software was developed to integrate all testing by means of a desk-top computer-controller. Near real-time data reduction and onboard graphics capabilities permit immediate assessment of test results. Provisions for disk storage of test data permit computer production of the test engineer's certification report. Software flexibility permits variation in the tests procedure, the ability to examine more closely those frequency bands which indicate compatibility problems, and the capability to incorporate additional test procedures.

Harrison, C. A.↗

An Overview of Behind-the-Meter Solar-Plus-Storage Program Design: With Considerations for India

Indian consumers have been deploying behind-the-meter generation (predominantly diesel backup, and, more recently, photovoltaic) and storage systems (predominantly lead-acid and other kinds of batteries as uninterrupted power supplies) by the millions for decades) to address reliability issues within the Indian power system. The same energy storage systems could provide additional services to the consumer and distribution companies if properly regulated and designed from the outset to be grid interactive. Grid-connected distributed solar PV (DPV), or rooftop solar, has also seen wide deployment in India and features prominently in the Government of India’s plans for a transition to clean, reliable, and affordable energy for all. At the same time, many utilities and state governments, as well as the central government in India are currently funding-constrained for both operational and future capital expenditures in the power sector, and some perceive customer-sited resources as exacerbating existing financial challenges. In that context, behind-the-meter energy storage systems paired with distributed photovoltaic (DPV) - with the capability to act as both generation and load - represent a potentially unique and disruptive power sector technology capable of providing a range of important services to customers, utilities, and the broader power system in India. This report aims to offer a comprehensive, evidence-based approach to designing customer programs based on experience in the United States that can help regulators, utilities, and policymakers in India manage the range of challenges and opportunities that increased behind-the-meter energy storage deployment will bring to the power system, in particular when these systems are paired with DPV.

14 SOLAR ENERGY↗

The Power and Energy Storage Systems Toolbox -- PSTess v.1.0

The Power and Energy Storage Systems Toolbox (PSTess) is a MATLAB-based computing package for dynamic simulation and analysis of utility-scale battery storage systems. This codebase is a fork of the Power Systems Toolbox Version 3.0, developed at Rensselaer Polytechnic Institute (RPI) and Cherry Tree Scientific Software. While PSTess shares a common lineage with PST, it is a substantially different application. As the name implies, the main distinguishing characteristic of PSTess is its ability to model inverter-based energy storage systems (ESS). The model that enables this is called ess.m, and it serves the dual role of representing ESS operational constraints and the generator/converter interface. With PSTess, the generator/converter interface is modeled as a controllable current source with the ability to modulate both active and reactive current. The model ess.m permits four-quadrant modulation, which allows it to represent a wide variety of inverter-based resources beyond energy storage when paired with an appropriate supplemental control model. Examples include utility-scale photovoltaic (PV) power plants, type 4 wind plants, and static synchronous compensators (STATCOM). This capability is especially useful for modeling hybrid plants that combine energy storage with renewable resources. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525. SAND2021-8322 O

Elliott, RyanT.↗

The Power and Energy Storage Systems Toolbox–PSTess (V1.0)

This document describes the Power and Energy Storage Systems Toolbox for MATLAB, abbreviated as PSTess. This computing package is a fork of the Power Systems Toolbox (PST). PST was originally developed at Rensselaer Polytechnic Institute (RPI) and later upgraded by Dr. Graham Rogers at Cherry Tree Scientific Software. While PSTess shares a common lineage with PST Version 3.0, it is a substantially different application. This document supplements the main PST manual by describing the features and models that are unique to PSTess. As the name implies, the main distinguishing characteristic of PSTess is its ability to model inverter-based energy storage systems (ESS). The model that enables this is called ess.m , and it serves the dual role of representing ESS operational constraints and the generator/converter interface. As in the WECC REGC_A model, the generator/converter interface is modeled as a controllable current source with the ability to modulate both real and reactive current. The model ess.m permits four-quadrant modulation, which allows it to represent a wide variety of inverter-based resources beyond energy storage when paired with an appropriate supplemental control model. Examples include utility-scale photovoltaic (PV) power plants, Type 4 wind plants, and static synchronous compensators (STATCOM). This capability is especially useful for modeling hybrid plants that combine energy storage with renewable resources or FACTS devices.

97 MATHEMATICS AND COMPUTING↗

Integrated Large-Scale Data Management Platform for Photovoltaic Power Conversion Equipment (PCE) Reliability Data

To meet the demand for accuracy and real-time capability of PV system degradation evaluation, massive volume data is needed to run high-fidelity and high-efficiency simulations and perform advanced data analysis. However, PV farm operators have a series of difficulties with PV inverter data, such as data collection from multiple channels, massive data storage, data management and massive data analysis. To address these challenges, we developed an integrated data management platform capable of data acquisition, processing, storage, query, and performing big data analysis utilizing AI algorithms. The platform can also achieve data correctness verification and provide an effective distributed data management solution to retrieve massive data and establish a connection to distributed computational frameworks.

data management platform↗

Integrated Large-Scale Data Management Platform for Photovoltaic Power Conversion Equipment (PCE) Reliability Data: Preprint

To meet the demand for accuracy and real-time capability of PV system degradation evaluation, massive volume data is needed to run high-fidelity and high-efficiency simulations and perform advanced data analysis. However, PV farm operators have a series of difficulties with PV inverter data, such as data collection from multiple channels, massive data storage, data management and massive data analysis. To address these challenges, we developed an integrated data management platform capable of data acquisition, processing, storage, query, and performing big data analysis utilizing AI algorithms. The platform can also achieve data correctness verification and provide an effective distributed data management solution to retrieve massive data and establish a connection to distributed computational frameworks.

data management↗

ACES: Infrastructure As Code. Model Optimization and Performance Capability

Infrastructure as Code (IaC) refers to managing infrastructure (networks, physical/virtual machines, storage, and connection topology) in a descriptive model/language, rather than configuring it manually or using interactive configuration tools. Just like source code can be compiled to generate the same binary code, IaC enables generating the same environment every time it is applied. IaC is a key DevOps practice and is generally used in conjunction with continuous integration (CI) and continuous delivery (CD). In CI, all code changes are merged into a mainline branch and validated multiple times a day as developers check in their changes to the source code. In CD on the other hand, code changes are automatically packaged for a new release-to-production on a regular basis. This typically enables teams to deliver software changes much more quickly and often. Developing and managing the ACES platform using (IaC) is vital for the robust deployment and continued sustainment of this foundational computing capability. IaC and DevOps practices will help us solve many of the common challenges often encountered in developing and maintaining compute infrastructure. First, it will make the provisioning, deployment, and maintenance of the compute infrastructure across multiple environments much more efficient. Second, these processes help make the overall system much more stable by continuously testing new changes as they are introduced to the system. Third, it allows us to be much more confident of the security controls in place since they can be tested as part of the CI process and all new changes can be audited and tracked. Finally, IaC enables the ACES Platform to be adaptable to the emerging technologies due to its ability to spin up different test beds to evaluate and incorporate these technologies. This document addresses common infrastructure-management challenges, describes what happens if they are not addressed, and highlights the value of utilizing IaC to tackle them. Finally, we will provide a high-level overview of the IaC and DevOps practices being utilized by the ACES Platform team.

97 MATHEMATICS AND COMPUTING↗

Impact of Electrode Thickness and Temperature on the Rate Capability of Li 4 Ti 5 O 12 /LiMn 2 O 4 Cells

Growing demand for stationary energy storage systems requires the development of low cost, long cycle life, safe batteries. Lithium-ion batteries (LiBs) utilizing Li 4 Ti 5 O 12 /LiMn 2 O 4 (LMO) cathode are promising candidates providing critical-material-free chemistry, high power capability, and long lifespan. However, their low energy density is a major drawback. In this work, we evaluate the rate performance of LTO/LMO cells fabricated with electrode loadings from 1.7 to 4.2 mAh cm -2 toward the development of high energy density and low cost LTO/LMO cells. The operating temperature is varied from 30 °C to 55 °C to evaluate the impact of electrode thickness vs temperature limitations on the electrode utilization. In addition, Newman modeling is performed to provide detailed understandings of the cell performance. Combining experimental and simulated results, we show the rate capability of the thicker electrodes is limited by the electrolyte transport. When the cells are discharged by applying pulsed current, Li + ion depletion is mitigated and the discharge capacity increases. Thus, high energy density LTO/LMO cells for BTMS applications can operate more efficiently when intermittent rest is applied. Finally, overcoming electrolyte transport limitations will be the key to enabling the development of high energy density LTO/LMO cells using thick electrodes.

25 ENERGY STORAGE↗

Thermochemical reduction modeling in a high-temperature moving-bed reactor for energy storage: 1D model

The design of robust and efficient high-temperature thermochemical reactors and determination of operating conditions are critical steps toward enabling high-efficiency long-duration solar energy storage. This work presents a computational model for the thermal reduction of a metal oxide material (Mg-Mn-O) up to 1450 °C and the coupled complex transport phenomena in a novel tubular thermal reactor design that features the capability for a high extent-of-reduction (high energy storage density) and inherent heat recuperation. A one-dimensional model coupling counter-current gas–solid flow, two-phase heat transfer, thermochemical redox reactions, and species transport in a moving-bed reactor is developed. Simplified versions of the model are validated with published results in the literature for packed beds with both inert and reactive particles; the fully coupled model is also validated with experimental measurements of a moving-bed reactor in terms of local temperatures and oxygen release at the exit. Detailed comparisons on the effects of different boundary conditions in the reaction zone (prescribed wall temperature vs. heat flux conditions) and formulations based on a simple uniform flow assumption vs. plug flow using Ergun equation for gas flow are investigated. The results are compared with experimental measurements, and for all cases, the energy flow components in the reactor system and the thermal to chemical conversion efficiency and overall system efficiency are computed. Finally, the predicted high thermal-to-chemical efficiency ~95% and system efficiency ~30% agree with experimental measurements.

25 ENERGY STORAGE↗

Probing the In Situ Pseudocapacitive Charge Storage in Ti 3 C 2 MXene Thin Films with X-ray Reflectivity

MXenes are a large family of two-dimensional materials that are attractive for energy storage due to their high-rate charging capabilities as well as for electrochemical actuators, water purification, and many other technologies. Ion intercalation during electrochemically driven charge and discharge processes is the fundamental process associated with MXene functionality, which we have characterized here using in situ and operando X-ray reflectivity (XRR). Experiments performed at the Advanced Photon Source at Argonne National Laboratory monitored the changes in the structure of a Ti 3 C 2 MXene film on a platinum current collector as a function of static applied potential between 0.3 and –0.7 V vs Ag/AgCl in an aqueous 0.1 M Li 2 SO 4 electrolyte. Negative potential sweeps lead to a contraction of 1.2 Å in the interlayer spacing and a loss of electron density between the layers, likely due to Li + ion insertion and water removal. The change in lattice spacing includes a continuous variation vs potential as well as an additional discrete contraction that occurs near –0.35 V that has the characteristics of a first-order transition. The continuous change in the MXene interlayer spacing is associated with the capacitive charge, while the discrete change in structure correlated to the weak feature in the cyclic voltammogram at –0.35 V can be interpreted as either a pseudocapacitive charging process or a potential-dependent change in capacity.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

GEOS: A performance portable multi-physics simulation framework for subsurface applications

GEOS is a simulation framework focused on solving tightly coupled multi-physics problems with an initial emphasis on subsurface reservoir applications. Currently, GEOS supports capabilities for studying carbon sequestration, geothermal energy, hydrogen storage, and related subsurface applications. The unique aspect of GEOS that differentiates it from existing reservoir simulators is the ability to simulate tightly coupled compositional flow, poromechanics, fault slip, fracture propagation, and thermal effects, etc. Extensive documentation is available on the GEOS documentation pages (GEOS Documentation, 2024). Note that GEOS, as presented here, is a complete rewrite of the previous incarnation of the GEOS referred to in (Settgast et al., 2017).

58 GEOSCIENCES↗

American-Made Challenges Round 2 Voucher: Orison Enables Solar

This report documents the technical assistance provided to Orison as part of the American-Made Challenges Round 2 Voucher: Orison Enables Solar project. A testbed was developed and used to demonstrate, using modeling and simulation, the capability of controlled behind-the-meter energy storage to (1) reduce net load variability caused by appliances and distributed generation and (2) enable customers to respond to the time-of-use pricing. We demonstrate that load leveling can shave peak loads or limit solar photovoltaic export and that load shifting enables customers to reduce load during “peak” pricing intervals. In the scenarios that we simulated, load leveling was effective up to the charging and discharging limits of the storage systems and the effectiveness of load shifting was a function of the energy capacity of the storage systems. This report describes the co-simulation testbed and the scenarios simulated, including controller setup and simulation results. Considerations for a multi-objective controller are also discussed.

14 SOLAR ENERGY↗

CB10412: Bulk CWA Destruction

The objective of this project was to eliminate and/or render bulk agent unusable by a threat entity via neutralization and/or polymerization of the bulk agent using minimal quantities of additives. We proposed the in situ neutralization and polymerization of bulk chemical agents (CAs) by performing reactions in the existing CA storage container via wet chemical approaches using minimal quantities of chemical based materials. This approach does not require sophisticated equipment, fuel to power generators, electricity to power equipment, or large quantities of decontaminating materials. By utilizing the CA storage container as the batch reactor, the amount of logistical resources can be significantly reduced. Fewer personnel are required since no sophisticated equipment needs to be set up, configured, or operated. Employing the CA storage container as the batch reactor enables the capability to add materials to multiple containers in a short period of time as opposed to processing one container at a time for typical batch reactor approaches. In scenarios where a quick response is required, the material can be added to all the CA containers and left to react on its own without intervention. Any attempt to filter the CA plus material solution will increase the rate of reaction due to increased agitation of the solution.

36 MATERIALS SCIENCE↗

Modular, Multifunction, Multiport and Medium Voltage Utility Scale SiC PV Inverter (Final Report)

This project is to develop and demonstrate a Modular, Multi-function, Multiport and Medium Voltage utility scale SiC solar inverter (M4 Inverter). The M4 Inverter is a next generation utility scale PV + storage inverter that can substantially reduce the levelized cost of energy (LCOE) while providing grid friendly ancillary services. Conventional utility scale solar inverters includes three parts, a megawatt rated solar inverter, a low frequency transformer (LFT) and a medium voltage switch gear. The proposed M4 Inverter directly converts the DC output of solar panels to medium voltage AC, eliminating the bulky and costly LFT. The M4 Inverter also has a DC port to interface with an additional energy storage device. This plus its bidirectional power flow capability, allows multiple functions in addition to PV maximum power tracking be achieved. These additional functionalities include but not limited to reactive power support, peak shaving, fast frequency regulation and synthetic inertia. Predicted LCOE reductions with these added functionalities, improved efficiency and longer lifetime time are more than 30% compared with the 2017 utility scale solar LCOE. A 1MVA SiC M4 Inverter was developed and tested at high power level. The project has also advanced the state of the art in controller hardware in the loop simulation capability. Power electronic innovations introduced in the M4 Inverter includes 1700V SiC MOSFET application in 1500V PV system, soft switching three-port power converters and modular converter architecture.

24 POWER TRANSMISSION AND DISTRIBUTION↗