Search NASA⌕ Search

SEARCH · Search NASA

Results for “surface reflection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

Simultaneous and Constrained Calibration of Multiple Hyperspectral Images Through a New Generalized Empirical Line Model

The empirical line (EL) calibration method is commonly used for atmospheric correction of remotely sensed spectral images and recovery of surface reflectance. The current EL-based methods are applicable to calibrate only single images. Therefore, the use of the EL calibration is impractical for imaging campaigns, where many (partially overlapped) images are acquired to cover a large area. In addition, the EL results are unconstrained and an undesired reflectance with negative values or larger than 100% can be obtained. In this paper, we use the standard EL model to formulate a new generalized empirical line (GEL) model. Based on the GEL, we present a novel method for simultaneous and constrained calibration of multiple images. This new method allows for calibration through multiple image constrained empirical line (MIcEL) and three additional calibration modes. Given a set of images, we use the available ground targets and automatically extracted tie points between overlapping images to calibrate all the images in the set simultaneously. Quantitative and visual assessments of the proposed method were carried out relatively to the off-the-shelf method quick atmospheric correction (QUAC), using real hyperspectral images and field measurements. The results clearly show the superiority of MIcEL with respect to the minimization of the difference between the reflectance values of the same object in different overlapping images. An assessment of the absolute accuracy, with respect to 11 field measurement points, shows that the accuracy of MIcEL, with an average mean absolute error (MAE) of ~11%, is comparable with respect to the QUAC.

47 OTHER INSTRUMENTATION↗

Cloud Detection over Sunglint Regions with Observations from the Earth Polychromatic Imaging Camera (EPIC)

With the ability to observe the entire sunlit side of the Earth, EPIC data have become an important resource for studying cloud daily variability. Inaccurate cloud masking is a great source of uncertainty. One main region that is prone to error in cloud masking is the sunglint area over ocean surfaces. Cloud detection over these regions is challenging for the EPIC instrument because of its limited spectral channels. Clear sky ocean surface reflectance from visible channels over sunglint is much larger than that over the non-glint areas and can exceed reflectance from thin clouds. This paper presents an improved EPIC ocean cloud masking algorithm (Version 3). Over sunglint regions (glint angle ≤ 25°), the algorithm utilizes EPIC’s oxygen (O2) A-band ratio (764nm to 780 nm) in addition to the 780 nm reflectance observations in masking tests. Outside the sunglint regions, a dynamic reflectance threshold for the Rayleigh corrected 780 nm reflectance is applied. The thresholds are derived as a function of glint angle. When compared with co-located data from the geosynchronous Earth orbit (GEO) and the low Earth orbit (LEO) observations, the consistency of the new ocean cloud mask algorithm has increased by 4~10% and 4~6% in the glint center and granule edges respectively. The false positive rate is reduced by 10~17%. Overall global ocean cloud detection consistency increases by 2%. This algorithm, along with other improvements to the EPIC cloud masks, has been implemented in the EPIC cloud products Version 3. This algorithm will improve the cloud daily variability analysis by removing the artificial peak at local noon time in the glint center latitudes and reducing biases in the early morning and late afternoon cloud fraction over ocean surfaces.

EPIC↗

Channel Rank Improvement in Urban Drone Corridors Using Passive Intelligent Reflectors

Multiple-input multiple-output (MIMO) techniques can help in scaling the achievable air-to-ground (A2G) channel capacity while communicating with drones. However, spatial multiplexing with drones suffers from rank deficient channels due to the unobstructed line-of-sight (LoS), especially in millimeter wave (mmWave) frequencies that use narrow beams. One possible solution is utilizing low-cost and low-complexity metamaterial based intelligent reflecting surfaces (IRS) to enrich the multipath environment, taking into account that the drones are restricted to fly only within well-defined drone corridors. A hurdle with this solution is placing the IRSs optimally. In this study, we propose an approach for IRS placement with a goal to improve the spatial multiplexing gains, and hence to maximize the average channel capacity in a predefined drone corridor. Our results at 6 GHz, 28 GHz and 60 GHz show that the proposed approach increases the average rates for all frequency bands for a given drone corridor, when compared with the environment where there are no IRSs present, and IRS-aided channels perform close to each other at sub-6 and mmWave bands.

99 GENERAL AND MISCELLANEOUS↗

Compact folded metasurface spectrometer

Abstract An optical design space that can highly benefit from the recent developments in metasurfaces is the folded optics architecture where light is confined between reflective surfaces, and the wavefront is controlled at the reflective interfaces. In this manuscript, we introduce the concept of folded metasurface optics by demonstrating a compact spectrometer made from a 1-mm-thick glass slab with a volume of 7 cubic millimeters. The spectrometer has a resolution of ~1.2 nm, resolving more than 80 spectral points from 760 to 860 nm. The device is composed of three reflective dielectric metasurfaces, all fabricated in a single lithographic step on one side of a substrate, which simultaneously acts as the propagation space for light. The folded metasystem design can be applied to many optical systems, such as optical signal processors, interferometers, hyperspectral imagers, and computational optical systems, significantly reducing their sizes and increasing their mechanical robustness and potential for integration.

47 OTHER INSTRUMENTATION↗

Solar Shutter

Solar receiver turned off by movable reflective shutter. When reflective surface interposed across optical axis, incoming solar heat reflected back to concentrator for rejection into space.

Hale, R. R.↗

Deformable Subreflector Computed by Geometric Optics

Distorted antenna surfaces forced to produce a uniform wave front. SUBFORMING employs geometric optics in determining subreflector coordinates to match main reflector surface with known distortions. Antenna with distorted paraboloidal reflecting surface forced to produce uniform wave front by using a Cassegrainian geometry with path-length-compensating subreflector. Program written in FORTRAN V for batch execution.

Williams, W. F.↗

Electrical properties of polyimides containing a near-surface deposit of silver

Films containing a surface or near-surface deposit of palladium, gold or copper metal as well as tin, cobalt, copper, or lithium oxides have been prepared by dissolving appropriate metal salts into poly(amide-acid)/N,N-dimethylacetamide solutions and curing the solvent cast films to temperatures up to 300 C. This preparation technique has been extended to evaluate the thermal, spectroscopic, and electrical characteristics of condensation polyimide films modified with silver nitrate. A near-surface deposit of metallic silver results but the reflective surface has high electrical resistivity (sheet resistivity) due to a polymer coating or overlayer above the metal. Details pertaining to the silver nitrate modified condensation polyimides are presented. Also, the applicability of the structural model and electrical model previously proposed for the cobalt oxide system are assessed.

Rancourt, J. D.↗

Two-dimensional high temperature strain measurement system

Two-dimensional optical strain measurements on high temperature test specimens are presented. This two-dimensional capability is implemented through a rotatable sensitive strain axis. Three components of surface strain can be measured automatically, from which the first and second principal strains are calculated. One- and two-dimensional strain measurements at temperatures beyond 750 C with a resolution of 15 microstrain are demonstrated. The system is based on a one-dimensional speckle shift technique. The speckle shift technique makes use of the linear relationship between surface strain and the differential shift of laser speckle patterns in the diffraction plane. Laser speckle is a phase effect that occurs when spatially coherent light interacts with an optically rough surface. Since speckle is generated by any diffusely reflecting surface, no specimen preparation is needed to obtain a good signal. Testing was done at room temperature on a flat specimen of Inconel 600 mounted in a fatigue testing machine. A load cell measured the stress on the specimen before and after acquiring the speckle data. Strain components were measured at 0 C (parallel to the load axis) and at plus or minus 45 C, and plots indicate the calculated values of the first and second principal strains. The measured values of Young's modulus and Poisson's ratio are in good agreement with handbook values. Good linearity of the principal strain moduli at high temperatures indicate precision and stability of the system. However, a systematic error in the high-temperature test setup introduced a scale factor in the slopes of the two-dimensional stress-strain curves. No high temperature effects, however, have been observed to degrade speckle correlation.

Lant, Christian T.↗

Laser Sounder for Global Measurement of CO2 Concentrations in the Troposphere from Space: Progress

We describe progress toward developing a laser-based technique for the remote measurement of the tropospheric CO2 concentrations from orbit. Our goal is to demonstrate a lidar technique and instrument technology that will permit measurements of the CO2 column abundance in the lower troposphere from aircraft at the few ppm level, with a capability of scaling to permit global CO2 measurements from orbit. Accurate measurements of the tropospheric CO2 mixing ratio from space are challenging due to the many potential error sources. These include possible interference from other trace gas species, the effects of temperature, clouds, aerosols & turbulence in the path, changes in surface reflectivity, and variability in dry air density caused by changes in atmospheric pressure, water vapor and topographic height. Some potential instrumental errors include frequency drifts in the transmitter, small transmission and sensitivity drifts in the instrument. High signal-to-noise ratios and measurement stability are needed for mixing ratio estimates at the few ppm level. We have been developing a laser sounder approach as a candidate for a future space mission. It utilizes multiple different laser transmitters to permit simultaneous measurement of CO2 and O2 extinction, and aerosol backscatter in the same measurement path. It directs the narrow co-aligned laser beams from the instrument's fiber lasers toward nadir, and measures the energy of the strong laser echoes reflected from the Earth's land and water surfaces. During the measurement its narrow linewidth lasers are rapidly tuned on- and off- selected CO2 line near 1572 nm and an O2 absorption line near 770 nm. The receiver measures the energies of the laser echoes from the surface and any clouds and aerosols in the path with photon counting detectors. Ratioing the on- to off-line echo pulse energies for each gas permits the column extinction and column densities of CO2 and O2 to be estimated simultaneously via the differential absorption lidar technique. For the on-line wavelengths, the side of the selected absorption lines are used, which due to pressure broadening, weights the measurements to the lower troposphere, where CO2 variations caused by surface sources and sinks are largest. Simultaneous measurements of O2 column abundance are made using an identical approach using an O2 line. The laser backscatter profiles from clouds and aerosols are measured with other lidar channels, which permits identifying measurements influenced by clouds and/or aerosol scattering in the path. For space use, our lidar would continuously measure at nadir in near polar circular orbit. Using dawn and dusk measurements made over the same region will make it possible to sample the diurnal variations in CO2 mixing ratios. A 1-m diameter telescope is used for the receiver for all wavelengths. When averaging over 50 seconds, our calculations show a SNR of approximately 1500 is achievable for each gas at each on- and off-line measurement. Measurements from such a mission can be used to generate monthly global maps of the lower tropospheric CO2 column abundance. Our calculations show global coverage with an accuracy of a few ppm with a spatial resolution of approximately 50,000 sq. km are achievable each month. We have demonstrated some key elements of the laser, detector and receiver approaches in the laboratory and with measurements over a 206 m horizontal path. These include stable measurements of CO2 line shapes in an absorption cell using a fiber laser amplifier seeded by a tunable diode laser, measurement of small amplitude changes at low optical signal levels with the PMT receiver, and comparison of the horizontal path measurements of CO2 against those from an in-situ instrument.

Abshire, J. B.↗

Compact micro-concentrator for photovoltaic cells

A reflector array comprises a plurality of partial parabolic reflectors arranged in rows and columns with each reflector directing radiation to a receiver or from a transmitter located at the focus of the reflector. In a compact photovoltaic cell arrangement, each cell is shielded from direct radiation by the adjacent reflector. The reflectors can be formed as one unit with reflective material or with the reflecting surfaces coated with aluminum, silver, or other suitable reflecting material. A secondary reflector can be positioned at the focus of a reflector for directing radiation to a receiver or from a transmitter located at a more accessible location in the array.

Terao, Akira↗

Asteroids - Surface composition from reflection spectroscopy

Minerals partly composing the surfaces of 14 asteroids are determined by using asteroid reflectance spectra and optical properties of meteorites and other materials. Individual electronic absorption features are identified in the asteroids' spectra. The energies, relative strengths, and shapes of these features are interpreted by using laboratory and theoretical studies. Analysis of the initial 14 asteroid reflectance spectra indicates the presence of the following types of surface materials: six carbonaceous chondrite-like; two stony-iron-like (metal/silicate ratio approximately equal to 1); one iron meteorite-like; one basaltic achondrite-like; and four silicate-metal assemblages (metal/silicate ratio approximately equal to 0.25). These results support the conclusion that the asteroid belt is a source of at least some meteoritic material, and they show a relation between certain asteroids and certain classes of meteorites.

Mccord, T. B.↗

Highly reflective polymeric substrates functionalized utilizing atomic layer deposition

Reflective surfaces are one of the key elements of solar plants to concentrate energy in the receivers of solar thermal electricity plants. Polymeric substrates are being considered as an alternative to the widely used glass mirrors due to their intrinsic and processing advantages, but optimizing both the reflectance and the physical stability of polymeric mirrors still poses technological difficulties. In this work, polymeric surfaces have been functionalized with ceramic thin-films by atomic layer deposition. The characterization and optimization of the parameters involved in the process resulted in surfaces with a reflection index of 97%, turning polymers into a real alternative to glass substrates. The solution we present here can be easily applied in further technological areas where seemingly incompatible combinations of polymeric substrates and ceramic coatings occur.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Deriving Albedo from Coupled MERIS and MODIS Surface Products

MERIS Level 2 surface reflectance products are now available to the scientific community. This paper demonstrates the production of MERIS-derived surface albedo and Nadir Bidirectional Reflectance Distribution Function (BRDF) adjusted reflectances by coupling the MERIS data with MODIS BRDF products. Initial efforts rely on the specification of surface anisotropy as provided by the global MODIS BRDF product for a first guess of the shape of the BRDF and then make use all of the coincidently available, partially atmospherically corrected, cloud cleared, MERIS observations to generate MERIS-derived BRDF and surface albedo quantities for each location. Comparisons between MODIS (aerosol-corrected) and MERIS (not-yet aerosol-corrected) surface values from April and May 2003 are also presented for case studies in Spain and California as well as preliminary comparisons with field data from the Devil's Rock Surfrad/BSRN site.

Gao, Feng↗

Secondary shock wave in laser-material interaction

In this work, the effects of shock driven process of the laser-ablated argon plume in a background gas environment are explored via molecular dynamics simulations. The primary shock wave propagation and its influence on the backward motion of the target material are delineated. It is observed that the strong pressure gradient inside the main shock wave overcomes the forward momentum of the plume and some compressed gas, leading to backward movement and redeposition on the target surface. Reflection of the backward moving gas on the target surface results in the secondary shock wave. Detailed investigation of the secondary shock wave phenomenon is provided, which gives, for the first time, an insight into formation and evolution of the internal gaseous shock at the atomistic level.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Pruning The ELM Survey: Characterizing Candidate Low-mass White Dwarfs through Photometric Variability

We assess the photometric variability of nine stars with spectroscopic T {sub eff} and log g values from the ELM Survey that locates them near the empirical extremely low-mass (ELM) white dwarf instability strip. We discover three new pulsating stars: SDSS J135512.34+195645.4, SDSS J173521.69+213440.6, and SDSS J213907.42+222708.9. However, these are among the few ELM Survey objects that do not show radial velocity (RV) variations that confirm the binary nature expected of helium-core white dwarfs. The dominant 4.31 hr pulsation in SDSS J135512.34+195645.4 far exceeds the theoretical cut-off for surface reflection in a white dwarf, and this target is likely a high-amplitude δ Scuti pulsator with an overestimated surface gravity. We estimate the probability to be less than 0.0008 that the lack of measured RV variations in four of eight other pulsating candidate ELM white dwarfs could be due to low orbital inclination. Two other targets exhibit variability as photometric binaries. Partial coverage of the 19.342 hr orbit of WD J030818.19+514011.5 reveals deep eclipses that imply a primary radius >0.4 R {sub ⊙}—too large to be consistent with an ELM white dwarf. The only object for which our time series photometry adds support to ELM white dwarf classification is SDSS J105435.78−212155.9, which has consistent signatures of Doppler beaming and ellipsoidal variations. We conclude that the ELM Survey contains multiple false positives from another stellar population at T {sub eff}≲9000 K, possibly related to the sdA stars recently reported from SDSS spectra.

79 ASTRONOMY AND ASTROPHYSICS↗

Improvement in the quantum sensitivity of InAs/InAsSb/InAsSbP heterostructure photodiodes

InAs/InAs{sub 0.88}Sb{sub 0.12}/InAs{sub 0.50}Sb{sub 0.20}P{sub 0.30} heterostructure photodiodes operating at room temperature in the spectral range 1-4.8 {mu}m are developed. It is shown that the formation of a curvilinear reflecting surface constituted by a number of hemispheres on the rearside of the photodiode chip leads to an increase in the quantum sensitivity of the photodiodes by a factor of 1.5-1.7 at wavelengths in the range 2.2-4.8 {mu}m. At an exposed photodiode area of 0.9 mm{sup 2} and a p-n junction area of 0.15 mm{sup 2}, a zero-bias differential resistance of 30 {Omega} and a quantum sensitivity of 0.24 electron/photon at a wavelength of 3 {mu}m are obtained. The operation of a photodiode with re-reflection of the photon flux in the crystal due to reflection from the curvilinear surface of the rearside of the photodiode chip is theoretically analyzed. The possibility of effective conversion of the re-reflected flux of photons into a photocurrent, with a simultaneous decrease in the p-n junction area, is demonstrated. An increase in the quantum sensitivity in the short-wavelength spectral range 1-2.2 {mu}m by 35% relative to the calculated data is observed, which is probably due to impact ionization in the narrow-gap active region.

36 MATERIALS SCIENCE↗