Search NASA⌕ Search

SEARCH · Search NASA

Results for “targeted quantification”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

Smart Methane Emission Detection System Development (Final Report)

Working with the Department of Energy’s National Energy Technology Laboratory, Southwest Research Institute® (SwRI®) developed a system to identify methane leaks reliably, accurately, and autonomously at critical midstream sections of the natural gas distribution network in real- time for the purpose of mitigating methane emissions using Optical Gas Imaging (OGI) cameras. SwRI’s Smart Leak Detection – Methane (SLED/M) adds a high degree of automation to the process of methane leak detection to minimize sources of human error, minimize response time to a leak event, and maximize midstream visibility. Furthermore, SwRI has been working towards integrating Quantitative OGI (QOGI) capabilities into this existing technology. By leveraging Deep Learning, SwRI now has the capability to estimate fugitive emission leak rates quickly and reliably, which allows operators to detect emissions, quantify leak rate, prioritize repairs, and validate the repairs in a single instrument. The next generation QOGI technology leverages the same cameras used in Leak Detection and Repair (LDAR) programs, with improvements in safety and speed for traditional quantification-based repairs, ultimately leading to less overhead cost for the operators. The goals for this research were to develop two types of models with the following goals: 1. Run in real-time on the edge (≥ 12 Hz) 2. Classification: Achieve less than 5% false positive detection 3. Classification: Achieve ≥ 95% methane plume detection rate 4. Regression: achieve ≤ 10 standard cubic feet per hour (scfh) prediction > 70% of the time In order to achieve these results, multiple infrared (IR) and other sensors were investigated in tandem with the midwave IR (MWIR) OGI to provide additional information to train the underlying models. Information on atmospheric conditions including humidity, temperature, pressure, and solar radiation was provided by a weather station. Several machine learning and deep learning architectures and methods, including looking at quantized classification networks and regressions networks, were explored. As further data was collected, curated, and labeled, it allowed for more refined regressive networks to be adequately trained, leading to better insight into the true flow rates being observed. An important valuable deliverable of this research effort was the development of an advanced network which underwent multiple iterations capable of giving a continuous output. The current network has a predicted mean average percentage error (MAPE) of 12.3% just outside our target goal of 10.00%, but an accuracy of 97.78% at ±50 scfh, well within the overall goal for the Department of Energy (DOE) program. Upon closer inspection, it was observed that more than 10% of datapoints contributing to the MAPE predictions were the result of low flow rate predictions and are beyond the sensitivity of instrument measurement as a result of normal operational variation and noise.

03 NATURAL GAS↗

A framework for assessment of predictive capability maturity and its application in nuclear thermal hydraulics

Here this work presents a formalized and computerized framework for the assessment of decision regarding the adequacy of a simulation tool for a nuclear reactor application. The decision regarding a code’s adequacy for an application is dependent on the assessment of different attributes that govern verification, validation, and uncertainty quantification of the code. In this work, the focus is on code validation. Therefore, the framework is developed and illustrated from the perspective of decision regarding the validation assessment of a code. Code validation assessment is performed based on the validation test results, data applicability, and process quality assurance factors. The process quality assurance factors warrant the trustworthiness of the evidence and help in checking people and process compliance with respect to the standard requirements. The proposed framework is developed using an argument modeling technique called Goal Structuring Notation (GSN). Goal structuring notation facilitates structural knowledge representation, information abstraction, evidence incorporation, and provides a skeletal structure for quantitative maturity assessment. The decision schema for the development of the decision model is based on the Predictive Capability Maturity Model (PCMM) and Analytic Hierarchy Process (AHP) and formalized using Goal structuring notation. Each decision attribute is formulated as a claim, where the degree of validity of the claim (attribute’s assessment) is expressed using different maturity levels. The GSN representation of the decision model is transformed into a confidence network to provide evidence-based quantitative maturity assessment using the Bayesian network. A metric based on the expected utility of maturity levels, called expected distance metric, is proposed to measure the distance between target maturity and achieved maturity on a scale of zero to one. Expected distance metric helps in comparing the assessment of different attributes and identification of major areas of concern in terms of modeling capability, data needs, and quality of assessment process. The practical application of the framework is demonstrated by a case study on validation assessment of a thermal-hydraulic code for a challenge problem called Departure from Nucleate Boiling (DNB).

42 ENGINEERING↗

Uncertainty-Guided Prediction Horizon of Phase-Resolved Ocean Wave Forecasting Under Data Sparsity: Experimental and Numerical Evaluation

Accurate short-term wave forecasting is critical for the safe and efficient operation of marine structures that rely on real-time, phase-resolved ocean wave information for control and monitoring purposes (e.g., digital twins). These systems often depend on environmental sensors (e.g., waverider buoys, wave-sensing LIDAR). Challenges arise when upstream sensor data are missing, sparse, or phase-shifted due to drift. This study investigates the performance of two machine learning models, time-series dense encoder (TiDE) and long short-term memory (LSTM), for forecasting phase-resolved ocean surface elevations under varying degrees of data degradation. We introduce the τ-trimming algorithm, which adapts the prediction horizon based on uncertainty thresholds derived from historical forecasts. Numerical wave tank (NWT) and wave basin experiments are used to benchmark model performance under short- and long-term data masking, spatially coarse sensor grids, and upstream phase shifts. Results show under a 50% probability of upstream data loss, the τ-trimmed TiDE model achieves a 46% reduction in error at the most upstream target, compared to 22% for LSTM. Furthermore, phase misalignment in upstream data introduces a near-linear increase in forecast error. Under moderate model settings, a ±3 s misalignment increases the mean absolute error by approximately 0.5 m, while the same error is accumulated at ±4 s using the more conservative approach. These findings inform the design of resilient, uncertainty-aware wave forecasting systems suited for realistic offshore sensing environments.

42 ENGINEERING↗

Exploration of zeroth-order wavefunctions and energies as a first step toward intramolecular symmetry-adapted perturbation theory

Non-covalent interactions occur between and within all molecules and have a profound impact on structural and electronic phenomena in chemistry, biology, and material science. Understanding the nature of inter- and intramolecular interactions is essential not only for establishing the relation between structure and properties, but also for facilitating the rational design of molecules with targeted properties. These objectives have motivated the development of theoretical schemes decomposing intermolecular interactions into physically meaningful terms. Among the various existing energy decomposition schemes, Symmetry-Adapted Perturbation Theory (SAPT) is one of the most successful as it naturally decomposes the interaction energy into physical and intuitive terms. Unfortunately, analogous approaches for intramolecular energies are theoretically highly challenging and virtually nonexistent. Here, we introduce a zeroth-order wavefunction and energy, which represent the first step toward the development of an intramolecular variant of the SAPT formalism. The proposed energy expression is based on the Chemical Hamiltonian Approach (CHA), which relies upon an asymmetric interpretation of the electronic integrals. The orbitals are optimized with a non-hermitian Fock matrix based on two variants: one using orbitals strictly localized on individual fragments and the other using canonical (delocalized) orbitals. The zeroth-order wavefunction and energy expression are validated on a series of prototypical systems. The computed intramolecular interaction energies demonstrate that our approach combining the CHA with strictly localized orbitals achieves reasonable interaction energies and basis set dependence in addition to producing intuitive energy trends. Our zeroth-order wavefunction is the primary step fundamental to the derivation of any perturbation theory correction, which has the potential to truly transform our understanding and quantification of non-bonded intramolecular interactions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Quantification of Tumor Volume Changes During Radiotherapy for Non-Small-Cell Lung Cancer

Purpose: Dose escalation for lung cancer is limited by normal tissue toxicity. We evaluated sequential computed tomography (CT) scans to assess the possibility of adaptively reducing treatment volumes by quantifying the tumor volume reduction occurring during a course of radiotherapy (RT). Methods and Materials: A total of 22 patients underwent RT for Stage I-III non-small-cell lung cancer with conventional fractionation; 15 received concurrent chemotherapy. Two repeat CT scans were performed at a nominal dose of 30 Gy and 50 Gy. Respiration-correlated four-dimensional CT scans were used for evaluation of respiratory effects in 17 patients. The gross tumor volume (GTV) was delineated on simulation and all individual phases of the repeat CT scans. Parenchymal tumor was evaluated unless the nodal volume was larger or was the primary. Subsequent image sets were spatially co-registered with the simulation data for evaluation. Results: The median GTV reduction was 24.7% (range, -0.3% to 61.7%; p < 0.001, two-tailed t test) at the first repeat scan and 44.3% (range, 0.2-81.6%, p < 0.001) at the second repeat scan. The volume reduction was not significantly different between patients receiving chemoradiotherapy vs. RT alone, a GTV >100 cm{sup 3} vs. <100 cm{sup 3}, and hilar and/or mediastinal involvement vs. purely parenchymal or pleural lesions. A tendency toward a greater volume reduction with increasing dose was seen, although this did not reach statistical significance. Conclusion: The results of this study have demonstrated significant alterations in the GTV seen on repeat CT scans during RT. These observations raise the possibility of using an adaptive approach toward RT of non-small-cell lung cancer to minimize the dose to normal structures and more safely increase the dose directed at the target tissues.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Development of a video image-based QA system for the positional accuracy of dynamic tumor tracking irradiation in the Vero4DRT system

Purpose: To develop and evaluate a new video image-based QA system, including in-house software, that can display a tracking state visually and quantify the positional accuracy of dynamic tumor tracking irradiation in the Vero4DRT system. Methods: Sixteen trajectories in six patients with pulmonary cancer were obtained with the ExacTrac in the Vero4DRT system. Motion data in the cranio–caudal direction (Y direction) were used as the input for a programmable motion table (Quasar). A target phantom was placed on the motion table, which was placed on the 2D ionization chamber array (MatriXX). Then, the 4D modeling procedure was performed on the target phantom during a reproduction of the patient’s tumor motion. A substitute target with the patient’s tumor motion was irradiated with 6-MV x-rays under the surrogate infrared system. The 2D dose images obtained from the MatriXX (33 frames/s; 40 s) were exported to in-house video-image analyzing software. The absolute differences in the Y direction between the center of the exposed target and the center of the exposed field were calculated. Positional errors were observed. The authors’ QA results were compared to 4D modeling function errors and gimbal motion errors obtained from log analyses in the ExacTrac to verify the accuracy of their QA system. The patients’ tumor motions were evaluated in the wave forms, and the peak-to-peak distances were also measured to verify their reproducibility. Results: Thirteen of sixteen trajectories (81.3%) were successfully reproduced with Quasar. The peak-to-peak distances ranged from 2.7 to 29.0 mm. Three trajectories (18.7%) were not successfully reproduced due to the limited motions of the Quasar. Thus, 13 of 16 trajectories were summarized. The mean number of video images used for analysis was 1156. The positional errors (absolute mean difference + 2 standard deviation) ranged from 0.54 to 1.55 mm. The error values differed by less than 1 mm from 4D modeling function errors and gimbal motion errors in the ExacTrac log analyses (n = 13). Conclusions: The newly developed video image-based QA system, including in-house software, can analyze more than a thousand images (33 frames/s). Positional errors are approximately equivalent to those in ExacTrac log analyses. This system is useful for the visual illustration of the progress of the tracking state and for the quantification of positional accuracy during dynamic tumor tracking irradiation in the Vero4DRT system.

60 APPLIED LIFE SCIENCES↗

Single-well experimental design for studying residual trapping of superciritcal carbon dioxide

The objective of our research is to design a single-well injection-withdrawal test to evaluate residual phase trapping at potential CO{sub 2} geological storage sites. Given the significant depths targeted for CO{sub 2} storage and the resulting high costs associated with drilling to those depths, it is attractive to develop a single-well test that can provide data to assess reservoir properties and reduce uncertainties in the appraisal phase of site investigation. The main challenges in a single-well test design include (1) difficulty in quantifying the amount of CO{sub 2} that has dissolved into brine or migrated away from the borehole; (2) non-uniqueness and uncertainty in the estimate of the residual gas saturation (S{sub gr}) due to correlations among various parameters; and (3) the potential biased S{sub gr} estimate due to unaccounted heterogeneity of the geological medium. To address each of these challenges, we propose (1) to use a physical-based model to simulation test sequence and inverse modeling to analyze data information content and to quantify uncertainty; (2) to jointly use multiple data types generated from different kinds of tests to constrain the Sgr estimate; and (3) to reduce the sensitivity of the designed tests to geological heterogeneity by conducting the same test sequence in both a water-saturated system and a system with residual gas saturation. To perform the design calculation, we build a synthetic model and conduct a formal analysis for sensitivity and uncertain quantification. Both parametric uncertainty and geological uncertainty are considered in the analysis. Results show (1) uncertainty in the estimation of Sgr can be reduced by jointly using multiple data types and repeated tests; and (2) geological uncertainty is essential and needs to be accounted for in the estimation of S{sub gr} and its uncertainty. The proposed methodology is applied to the design of a CO{sub 2} injection test at CO2CRC's Otway Project Site, Victoria, Australia.

54 ENVIRONMENTAL SCIENCES↗

WIPP Certification of the Retrieval Box Assay System at the Advanced Mixed Waste Treatment Plant, Idaho - 16241

The Retrieval Box Assay System (RBAS) at the Advanced Mixed Waste Treatment Plant (AMWTP) is an Imaging Passive Active Neutron system supplemented with a High Purity Germanium (HPGe) gamma system for the quantification of Pu-239 Fissile Gram Equivalent (FGE) and transuranic (TRU) alpha activity of waste containers of various sizes up to 249 cm x 149 cm x 198 cm (Length x Width x Height). The system was originally calibrated in 2002 (with a range of surrogate matrices and radioactive sources in a 213 cm x 122 cm x 122 cm FRP box) and has been operational for over a decade. As of August 2015, the RBAS has measured approximately 18,000 boxes (50,000 m3 of waste) which has subsequently been fed into the facility's treatment process. Its success, and the wide envelope of waste that it can characterize, has led AMWTP to extend the RBAS mission to include WIPP certification. As part of this new project, the instrument must be capable of meeting WIPP's Waste Acceptance Criteria (WAC) which include reporting activities and masses of the 10 WIPP-tracked radionuclides. The system will be required to assay sludge and debris waste streams, shredded waste and large metal items. The container size includes Standard Waste Box (SWBs), Fiberglass Reinforced Plywood (FRPs) and large Shredder Boxes. Sludge matrices will be loaded into 210-liter (55-gallon) drums and placed inside an SWB. After assay, boxes will be over-packed into SLB-II's for shipment to WIPP. The target waste streams will contain mixtures of Weapons Grade plutonium, Heat Source plutonium (high in Pu-238 content) and Mixed Oxide (MOX). The activity of the waste is expected to encompass a wide dynamic range of activity from low-level waste (LLW) to TRU with up to several hundred grams of plutonium. Some packages will have high gamma activity associated with fission and activation products such as Cs-137 and Co-60. The existing RBAS hardware (detectors, electronics, assay chamber etc.) was retained for this project. Two lead filters were provided and installed on the existing filter wheels to attenuate the gamma ray flux from the highest activity boxes to avoid overload of the HPGe detectors. The new software suite includes PC-FRAM (Version 5), which is used for the isotopic analysis of the gamma spectra. Integration of FRAM and neutron results is performed using a software package known as RBAS WIPP Analysis Reporting Software (RWARS). This package also performs matrix dependent background adjustments. Other upgrades provided include automated tests that identify when assay parameters fall outside a predetermined range and a new Quality Checking (QC) application. Minimum Detectable Activity (MDA) values were determined for the active and passive neutron modes as a function of measured matrix correction indices. The resulting Minimum Detectable Concentration (MDC) has been demonstrated to be less than 3700 Bq/g alpha activity (100 nCi/g). Modifications were performed to update the system TMU parameters to accommodate assay of non-standard size boxes and a wider range of matrix materials. A series of calibration confirmation, measurements were performed on site in 2014 using a representative range of surrogate boxes and radioactive sources including Pu. The WIPP WAC performance criteria were successfully demonstrated up to 157 g Pu and the system passed its first Performance Demonstration Program (PDP) cycle in the Spring of 2015. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Measuring Plant Metabolite Abundance in Spearmint ( Mentha spicata L.) with Raman Spectra to Determine Optimal Harvest Time

A fast field-deployable method utilizing Raman spectroscopy to determine the optimal harvest time of plants to extract the highest abundance of target metabolites is presented. Rosmarinic acid is a metabolite extracted from spearmint (Mentha spicata L.). Leaves from commercial “Native” and proprietary clonal line “KI110” spearmint were measured as a function of cell type and age to determine rosmarinic acid abundance. A linear regression model with leave-one-out cross-validation (R 2 CV = 0.61, RMSECV = 11.1 mg/g) was developed between selected Raman peak areas and rosmarinic acid concentrations determined by high-performance liquid chromatography (HPLC). A principal component analysis (PCA) model was also developed to determine rosmarinic acid abundance. The method may be suited to the analysis of many agriculturally relevant plant species and metabolites with distinct Raman peaks.

59 BASIC BIOLOGICAL SCIENCES↗

FY25 Theory and Simulation Performance Target: Development of an integrated modeling framework for fusion reactor design and assessment (Final Report)

This report documents the FY25 Theory and Simulation Performance Target (TSPT) of developing an integrated modeling framework for fusion reactor design and assessment (FREDA). Over Q1-Q4, new capabilities were developed across both plasma and engineering domains and demonstrated on an example representation of a Compact Advanced Tokamak with a Dual Cooled Lead Lithium blanket. This represents a first-of-a-kind demonstration of coupled core-to-wall-to-engineering for a reactor. Self-consistent CESOL workflows were applied to provide core, pedestal, and SOL prediction; new modules were developed for energetic particle stability (FAR3D) and transport (TGLF-EP) analysis; and boundary plasma modeling (SOLPS-ITER, BOUT++/Hermes-3) was expanded to evaluate wall and divertor heat fluxes and interface with engineering thermal analysis. A parameterized CAD tool, TRACER, was expanded to generate medium-fidelity divertor, blanket, and coil geometries; OpenFOAM and Diablo workflows were applied for first-wall and divertor thermal analyses with helium cooling; and reduced-order models were created for high-mass-flux divertor cooling. Magnet multiphysics capabilities were verified between Elmer, Diablo, and a new MFEM-based solver, and workflows enable stress, thermal, and neutron-fluence analysis of TF coils with neutronics-driven heating. Nuclear and blanket analysis workflows were demonstrated, including tritium breeding, transport, and CFD-informed thermo-mechanical assessment. Preliminary multi-fidelity uncertainty quantification workflows were applied to boundary modeling codes and shown to achieve variance reductions with fewer high-fidelity boundary simulations. Key findings highlight the challenges of resolving the ITEP gap to find suitable balance between wall and divertor loads, neutron heating, and practical limits of PFC cooling. Next step priorities are to develop automated workflows to check boundary code convergence and detachment, implement tighter physics-engineering CAD provenance tracking, and inclusion of plasma-material interface models for SLAG and tungsten cracking behavior. Collectively, these developments establish sophisticated capabilities for predictive, multi-fidelity, whole-device modeling that integrates plasma physics, materials, magnets, and nuclear engineering to guide pathways to viable Fusion Pilot Plant design points.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A robust real-time surface reconstruction method on point clouds captured from a 3D surface photogrammetry system

Purpose: To develop a robust and real-time surface reconstruction method on point clouds captured from a 3D surface photogrammetry system. Methods: The authors have developed a robust and fast surface reconstruction method on point clouds acquired by the photogrammetry system, without explicitly solving the partial differential equation required by a typical variational approach. Taking advantage of the overcomplete nature of the acquired point clouds, their method solves and propagates a sparse linear relationship from the point cloud manifold to the surface manifold, assuming both manifolds share similar local geometry. With relatively consistent point cloud acquisitions, the authors propose a sparse regression (SR) model to directly approximate the target point cloud as a sparse linear combination from the training set, assuming that the point correspondences built by the iterative closest point (ICP) is reasonably accurate and have residual errors following a Gaussian distribution. To accommodate changing noise levels and/or presence of inconsistent occlusions during the acquisition, the authors further propose a modified sparse regression (MSR) model to model the potentially large and sparse error built by ICP with a Laplacian prior. The authors evaluated the proposed method on both clinical point clouds acquired under consistent acquisition conditions and on point clouds with inconsistent occlusions. The authors quantitatively evaluated the reconstruction performance with respect to root-mean-squared-error, by comparing its reconstruction results against that from the variational method. Results: On clinical point clouds, both the SR and MSR models have achieved sub-millimeter reconstruction accuracy and reduced the reconstruction time by two orders of magnitude to a subsecond reconstruction time. On point clouds with inconsistent occlusions, the MSR model has demonstrated its advantage in achieving consistent and robust performance despite the introduced occlusions. Conclusions: The authors have developed a fast and robust surface reconstruction method on point clouds captured from a 3D surface photogrammetry system, with demonstrated sub-millimeter reconstruction accuracy and subsecond reconstruction time. It is suitable for real-time motion tracking in radiotherapy, with clear surface structures for better quantifications.

60 APPLIED LIFE SCIENCES↗

Testing of an Iodine and Tritium Capture System for an NO₂-Based Tritium Pretreatment Process

The reprocessing of used nuclear fuel would release volatile radionuclides into the off-gas streams of a processing plant, including ³H, ¹⁴C, ⁸⁵Kr, and ¹²⁹I. One potential simplification to the management of the off-gas streams could be achieved through an efficient tritium pretreatment (TPT) step in which the UO₂ fuel is oxidized by either air or NO₂ before dissolution. The oxidation of the UO₂ fuel matrix will result in the release of tritium from the fuel. Upfront release of tritium from the fuel in a pretreatment step with subsequent tritium abatement can minimize or eliminate the distribution of tritium throughout a plant. This can decrease or eliminate the need for tritium capture on multiple off-gas streams and prevent distribution to the aqueous inventory. The use of NO₂ as the oxidant in an advanced tritium pretreatment (ATPT) allows for the oxidation to be performed at lower temperatures and may also result in the quantitative release of iodine from the fuel. The ATPT off-gas will contain up to 75 vol% NO₂ gas. Spencer et al. identified the most promising iodine sorbent as silver nitrate-impregnated alumina (AgA) and the most promising tritium sorbents as 3Å molecular sieve (3Å MS) and silica gel for radionuclide capture from ATPT off-gas streams. An initial series of tests were conducted in fiscal years 2017–2018 with the intent of demonstrating the recovery of iodine and tritium using these sorbents from a recirculating gas stream that simulated the NO₂ recycle loop envisioned for the ATPT system. These initial tests showed low tritium recoveries and significant variations in the iodine recovery on the AgA. Ultimately it was concluded, following disassembly of the system, that corrosion within the system was partially the cause of the poor recovery of both species. All components of that system were disposed of at the end of the analysis. One of the conclusions drawn from the initial tests pointed to the reconsideration of the materials of construction. Based on that recommendation a new test bed for the advanced TPT off-gas system, that addresses the issues identified in the fiscal years 2017 and 2018 scoping tests, was designed and constructed. The test bed used high nickel alloys wherever possible to address the previously observed corrosion issues, a redesigned surge tank to permit ease of purging, an improved feed injection system and a more modular system design that allowed testing of incremental increases in system complexity to allow the isolation of any element that results in changes to recovery of target species. Accompanying that design, a multifaceted test plan was completed. The overarching goals of this test series were two-fold. The first goal was to demonstrate the ability to recover both the iodine and tritium that would be released during TPT in a manner that the releases from the fuel can be quantified. The second goal was to demonstrate that the combined recovery system could operate in any of the three proposed TPT modes (once-through air or O₂, recirculating air or O₂, or recirculating NO x ). A total of 22 tests were completed. Ten tests examined tritium behavior under varying operating parameters, 8 tests examined iodine behavior under varying operating parameters, and 4 tests examined both tritium and iodine behavior. Silica gel was used for the tritium sorbent, and AgA or Ag-mordenite (AgZ) was used as the iodine sorbent. The following conclusions were drawn: Full recovery is achieved for both sorbates when no sorbent is in place indicating no accumulation within the test system. In even the simplest of the configurations (i.e., no sorbents in the columns), iodine is more difficult to transport and recover from the system than tritium. Analysis of the AgA iodine sorbent beds from the integrated tritium and iodine tests indicate quantitative iodine recovery can be achieved (within anticipated experimental errors). This system may provide a means for the quantification of the iodine released by the ATPT process within the experimental uncertainties. This would support 0.33 to 1.00 kg demonstrations of the ATPT process with actual used nuclear fuel. Iodine penetrated further into AgZ than into AgA when operated in gas recirculation mode. Tritium adsorbs to and cannot be fully recovered from the 10-cm column of silica gel at regeneration temperatures up to 140 °C.; Tritium adsorbs to and cannot be recovered from the 10-cm column of AgA at desorption temperatures up to 200 °C. Co-adsorbed tritium was recovered to a greater extent from AgZ than from AgA, but recovery was not complete. No visible corrosion was observed in the test system.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Proteomics investigation of endogenous S-nitrosylation in Arabidopsis

Highlights: Black-Right-Pointing-Pointer Identification and quantification of nitrosothiols. Black-Right-Pointing-Pointer A first dataset of endogenously nitrosylated cysteines in Arabidopsis cells. Black-Right-Pointing-Pointer Nitrosothiols display apolar motifs not located in close vicinity of cysteines. Black-Right-Pointing-Pointer Salt stress alters the endogenous nitrosylation of specific cysteines in Arabidopsis. -- Abstract: S-Nitrosylation emerges as an important protein modification in many processes. However, most data were obtained at the protein level after addition of a NO donor, particularly in plants where information about the cysteines nitrosylated in these proteins is scarce. An adapted work-flow, combining the classical biotin switch method and labeling with isotope-coded affinity tags (ICAT), is proposed. Without addition of NO donor, a total of 53 endogenous nitrosocysteines was identified in Arabidopsis cells, in proteins belonging to all cell territories, including membranes, and covering a large panel of functions. This first repertoire of nitrosothiols in plants enabled also preliminary structural description. Three apolar motifs, not located in close vicinity of cysteines and accounting for half the dataset, were detected and are proposed to complement nitrosylation prediction algorithms, poorly trained with plant data to date. Analysis of changes induced by a brief salt stress showed that NaCl modified the nitrosylation level of a small proportion of endogenously nitrosylated proteins and did not concern all nitrosothiols in these proteins. The possible role of some NO targets in the response to salt stress was discussed.

60 APPLIED LIFE SCIENCES↗

Sequential Learning of Active Subspaces

This study shows that in recent years, active subspace methods (ASMs) have become a popular means of performing subspace sensitivity analysis on black-box functions. Naively applied, however, ASMs require gradient evaluations of the target function. In the event of noisy, expensive, or stochastic simulators, evaluating gradients via finite differencing may be infeasible. In such cases, often a surrogate model is employed, on which finite differencing is performed. When the surrogate model is a Gaussian process (GP), we show that the ASM estimator is available in closed form, rendering the finite-difference approximation unnecessary. We use our closed-form solution to develop acquisition functions focused on sequential learning tailored to sensitivity analysis on top of ASMs. We also show that the traditional ASM estimator may be viewed as a method of moments estimator for a certain class of GPs. We demonstrate how uncertainty on GP hyperparameters may be propagated to uncertainty on the sensitivity analysis, allowing model-based confidence intervals on the active subspace. Our methodological developments are illustrated on several examples.

97 MATHEMATICS AND COMPUTING↗

Arctic Black Carbon Loading and Profile Using the Single-Particle Soot Photometer (SP2) Field Campaign Report

One of the major issues confronting aerosol climate simulations of the Arctic and Antarctic cryospheres is the lack of detailed data on the vertical and spatial distribution of aerosols with which to test these models. This is due, in part, to the inherent difficulty of conducting such measurements in extreme environments. However given the pronounced sensitivity of the polar regions to radiative balance perturbations, it is incumbent upon our community to better understand and quantify these perturbations, and their unique feedbacks, so that robust model predictions of this region can be realized. One class of under-measured radiative forcing agents in the polar region is the absorbing aerosol—black carbon and brown carbon. Black carbon (BC; also referred to as light-absorbing carbon [LAC], refractory black carbon [rBC], and soot) is second only to CO2 as a positive forcing agent. Roughly 60% of BC emissions can be attributed to anthropogenic sources (fossil fuel combustion and open-pit cooking), with the remaining fraction being due to biomass burning. Brown carbon (BrC), a major component of biomass burning, collectively refers to non-BC carbonaceous aerosols that typically possess minimal light absorption at visible wavelengths but exhibit pronounced light absorption in the near-ultraviolet (UV) spectrum. Both species can be sourced locally or be remotely transported to the Arctic region and are expected to perturb the radiative balance. The work conducted in this field campaign addresses one of the more glaring deficiencies currently limiting improved quantification of the impact of BC radiative forcing in the cryosphere: the paucity of data on the vertical and spatial distributions of BC. By expanding the Gulfstream aircraft (G-1) payload for the U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) Climate Research Facility-sponsored ACME-V campaign to include the Single-Particle Soot Photometer (SP2)) and leveraging the ACME-V campaign’s deployment within the Arctic Circle during the summer of 2015 (Deadhorse, Alaska [70° 12' 20" N, 148° 30' 42" W]), the truly unique opportunity presented itself to acquire profile data on BC loading at little additional cost. Since the SP2 is a particle-resolved measurement, the resulting data set provides refractory black carbon (rBC) mass loadings, size and mass distributions, and rBC-containing particle mixing state, all of which are expected to readily find value in the modeling community. As part of the ACME-V (http://www.arm.gov/campaigns/aaf2014armacmev) campaign, CO, CO2, and CH4 were also measured, providing the unique opportunity for carbon closure. We will also work closely with modelers who require such data and expect this collaboration will lead directly to a better understanding of the climate impacts of BC in the Arctic. The primary measurement objective was to acquire airborne data on the vertical and spatial distributions of refractory black carbon (rBC) loading, size and mass distribution, and particle mixing state. The primary scientific objective was to provide a targeted data set of rBC particle distributions to better understand and constrain the impact of black carbon radiative forcing in the cryosphere. The SP2-based data set during this campaign is available in the DOE-ARM archive (http://www.arm.gov/campaigns/aaf2015abclp).

54 ENVIRONMENTAL SCIENCES↗

High Accuracy Signal Validation Framework for Sensor Calibration Assessment in NPPs

Effective and efficient health management of sensing channels and instrumentation supports reliable and accurate process monitoring capacities in any industry. Current practice in the nuclear industry relies on periodic calibration assessment and correction activities. This time based maintenance technique consists of three steps: i) removal of sensor to a test environment, ii) testing and recalibration, and iii) reinstallation of sensor into its working environment. This procedure is highly labor intensive, adds to the outage cost and timeline, and contributes to worker radiation exposure and ALARA requirements. Furthermore, the human element contributes to error factors in all stages of the procedure. The effectiveness of this calibration procedure after sensors are returned to working environmental variables also raises concerns, and the practicability of this periodic approach is uncertain for future reactor designs with longer operating cycles between refueling outages. Studies indicate that periodic calibration assessment find only 10% of sensing instrumentations with calibration issues during a single outage (18- 24 months), meaning at least 90% of sensors are undergoing unnecessary maintenance actions. This provides an opportunity to maintain the current levels of safety and functional integrity with fewer, more targeted maintenance actions and lower economic burden. Performance-based maintenance planning shows much promise over current periodic maintenance approaches. Specifically, online monitoring (OLM) utilizes the continually collected process data to non-intrusively monitor the calibration status of process instrumentation and detect the onset of de-calibration, thereby minimizing the number of recalibration procedures required. Ultimately, this can lead to termination of time based recalibration at NPPs. OLM utilizes the process measurements made for process monitoring and control to evaluate the calibration status of the sensors and instrumentation making the measurements. OLM can detect and differentiate sensor faults and process anomalies, thus providing a valuable tool to suit the industry's and regulatory body's requirements. Though supported by more than a decade of research, OLM for sensor calibration assessment is yet to be implemented in the US fleet due to regulatory requirements and constraints. As shown in Figure 1, OLM utilizes process data to train statistical models that predict normal, error-free process behavior. Measured process values are compared with error-corrected predictions to ascertain the presence of faults. The reliability of OLM is dependent on the quality of its predictions, measured in part by the uncertainty in these predictions. This research develops a framework to accurately quantify the prediction uncertainty based on Bayesian inference techniques to provide the required confidence levels for OLM systems. The expected outcomes include signal validation by high-accuracy, high-confidence uncertainty quantification for variable sensor types and operating ranges. Furthermore, the framework will facilitate fault detection capacities and so-called virtual sensors, a capability to replace faulty sensor measurements with error-corrected values when a sensor fault is detected. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

TH-A-207B-00: Shear-Wave Imaging and a QIBA US Biomarker Update

Imaging of tissue elastic properties is a relatively new and powerful approach to one of the oldest and most important diagnostic tools. Imaging of shear wave speed with ultrasound is has been added to most high-end ultrasound systems. Understanding this exciting imaging mode aiding its most effective use in medicine can be a rewarding effort for medical physicists and other medical imaging and treatment professionals. Assuring consistent, quantitative measurements across the many ultrasound systems in a typical imaging department will constitute a major step toward realizing the great potential of this technique and other quantitative imaging. This session will target these two goals with two presentations. A. Basics and Current Implementations of Ultrasound Imaging of Shear Wave Speed and Elasticity - Shigao Chen, Ph.D. Learning objectives-To understand: Introduction: Importance of tissue elasticity measurement Strain vs. shear wave elastography (SWE), beneficial features of SWE The link between shear wave speed and material properties, influence of viscosity Generation of shear waves External vibration (Fibroscan) ultrasound radiation force Point push Supersonic push (Aixplorer) Comb push (GE Logiq E9) Detection of shear waves Motion detection from pulse-echo ultrasound Importance of frame rate for shear wave imaging Plane wave imaging detection How to achieve high effective frame rate using line-by-line scanners Shear wave speed calculation Time to peak Random sample consensus (RANSAC) Cross correlation Sources of bias and variation in SWE Tissue viscosity Transducer compression or internal pressure of organ Reflection of shear waves at boundaries B. Elasticity Imaging System Biomarker Qualification and User Testing of Systems – Brian Garra, M.D. Learning objectives-To understand: Goals Review the need for quantitative medical imaging Provide examples of quantitative imaging biomarkers Acquaint the participant with the purpose of the RSNA Quantitative Imaging Biomarker Alliance and the need for such an organization Review the QIBA process for creating a quantitative biomarker Summarize steps needed to verify adherence of site, operators, and imaging systems to a QIBA profile Underlying Premise and Assumptions Objective, quantifiable results are needed to enhance the value of diagnostic imaging in clinical practice Reasons for quantification Evidence based medicine requires objective, not subjective observer data Computerized decision support tools (eg CAD) generally require quantitative input. Quantitative, reproducible measures are more easily used to develop personalized molecular medical diagnostic and treatment systems What is quantitative imaging? Definition from Imaging Metrology Workshop The Quantitative Imaging Biomarker Alliance Formation 2008 Mission Structure Example Imaging Biomarkers Being Explored Biomarker Selection Groundwork Draft Protocol for imaging and data evaluation QIBA Profile Drafting Equipment and Site Validation Technical Clinical Site and Equipment QA and Compliance Checking Ultrasound Elasticity Estimation Biomarker US Elasticity Estimation Background Current Status and Problems Biomarker Selection-process and outcome US SWS for Liver Fibrosis Biomarker Work Groundwork Literature search and analysis results Phase I phantom testing-Elastic phantoms Phase II phantom testing-Viscoelastic phantoms Digital Simulated Data Protocol and Profile Drafting Protocol: based on UPICT and existing literature and standards bodies protocols Profile-Current claims, Manufacturer specific appendices What comes after the profile Profile Validation Technical validation Clinical validation QA and Compliance Possible approaches Site Operator testing Site protocol re-evaluation Imaging system Manufacturer testing and attestation User acceptance testing and periodic QA Phantom Tests Digital Phantom Based Testing Standard QA Testing Remediation Schemes Profile Evolution Towards additional applications Towards higher accuracy and precision Supported in part by NIH contract HHSN268201300071C from NIBIB. Collaboration with GE Global Research, no personal support.; S. Chen, Some technologies described in this presentation have been licensed. Mayo Clinic and Dr. Chen have financial interests these technologies.

60 APPLIED LIFE SCIENCES↗

TH-A-207B-01: Basics and Current Implementations of Ultrasound Imaging of Shear Wave Speed and Elasticity

Imaging of tissue elastic properties is a relatively new and powerful approach to one of the oldest and most important diagnostic tools. Imaging of shear wave speed with ultrasound is has been added to most high-end ultrasound systems. Understanding this exciting imaging mode aiding its most effective use in medicine can be a rewarding effort for medical physicists and other medical imaging and treatment professionals. Assuring consistent, quantitative measurements across the many ultrasound systems in a typical imaging department will constitute a major step toward realizing the great potential of this technique and other quantitative imaging. This session will target these two goals with two presentations. A. Basics and Current Implementations of Ultrasound Imaging of Shear Wave Speed and Elasticity - Shigao Chen, Ph.D. Learning objectives-To understand: Introduction: Importance of tissue elasticity measurement Strain vs. shear wave elastography (SWE), beneficial features of SWE The link between shear wave speed and material properties, influence of viscosity Generation of shear waves External vibration (Fibroscan) ultrasound radiation force Point push Supersonic push (Aixplorer) Comb push (GE Logiq E9) Detection of shear waves Motion detection from pulse-echo ultrasound Importance of frame rate for shear wave imaging Plane wave imaging detection How to achieve high effective frame rate using line-by-line scanners Shear wave speed calculation Time to peak Random sample consensus (RANSAC) Cross correlation Sources of bias and variation in SWE Tissue viscosity Transducer compression or internal pressure of organ Reflection of shear waves at boundaries B. Elasticity Imaging System Biomarker Qualification and User Testing of Systems – Brian Garra, M.D. Learning objectives-To understand: Goals Review the need for quantitative medical imaging Provide examples of quantitative imaging biomarkers Acquaint the participant with the purpose of the RSNA Quantitative Imaging Biomarker Alliance and the need for such an organization Review the QIBA process for creating a quantitative biomarker Summarize steps needed to verify adherence of site, operators, and imaging systems to a QIBA profile Underlying Premise and Assumptions Objective, quantifiable results are needed to enhance the value of diagnostic imaging in clinical practice Reasons for quantification Evidence based medicine requires objective, not subjective observer data Computerized decision support tools (eg CAD) generally require quantitative input. Quantitative, reproducible measures are more easily used to develop personalized molecular medical diagnostic and treatment systems What is quantitative imaging? Definition from Imaging Metrology Workshop The Quantitative Imaging Biomarker Alliance Formation 2008 Mission Structure Example Imaging Biomarkers Being Explored Biomarker Selection Groundwork Draft Protocol for imaging and data evaluation QIBA Profile Drafting Equipment and Site Validation Technical Clinical Site and Equipment QA and Compliance Checking Ultrasound Elasticity Estimation Biomarker US Elasticity Estimation Background Current Status and Problems Biomarker Selection-process and outcome US SWS for Liver Fibrosis Biomarker Work Groundwork Literature search and analysis results Phase I phantom testing-Elastic phantoms Phase II phantom testing-Viscoelastic phantoms Digital Simulated Data Protocol and Profile Drafting Protocol: based on UPICT and existing literature and standards bodies protocols Profile-Current claims, Manufacturer specific appendices What comes after the profile Profile Validation Technical validation Clinical validation QA and Compliance Possible approaches Site Operator testing Site protocol re-evaluation Imaging system Manufacturer testing and attestation User acceptance testing and periodic QA Phantom Tests Digital Phantom Based Testing Standard QA Testing Remediation Schemes Profile Evolution Towards additional applications Towards higher accuracy and precision Supported in part by NIH contract HHSN268201300071C from NIBIB. Collaboration with GE Global Research, no personal support.; S. Chen, Some technologies described in this presentation have been licensed. Mayo Clinic and Dr. Chen have financial interests these technologies.

60 APPLIED LIFE SCIENCES↗