Search NASA⌕ Search

SEARCH · Search NASA

Results for “temperature profiles”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

Investigating Temperature Uniformity and Accuracy in PV Module Lamination: A Verification Study

This study investigates the temperature uniformity and accuracy of a photovoltaic (PV) module lamination process by addressing inconsistencies identified in 2017 data where irregular temperature changes were observed across setpoints. The 2017 data showed a notable drop in temperature upon bladder initiation, except for the 145 degrees Celsius profile. This inconsistency indicated potential inaccuracies in manual data recording methods. To address this concern, a verification experiment was conducted to evaluate temperature uniformity across the 2014 Bent River SPL2828 laminator platen and within test samples. Thermocouples, paired with Omega data acquisition software, were deployed to measure temperatures at multiple platen locations and within test samples. The experiment compared lamination temperatures of polyethylene-co-vinyl acetate (EVA) encapsulant when paired with solite glass or TPE backsheets. The methodology included verifying temperature uniformity directly on the platen and by using a large glass/EVA/glass sample using multiple thermocouples. Smaller samples were built with glass/EVA/glass and glass/EVA/backsheet configurations with one centered thermocouple to verify and compare sample temperatures. This verification aims to refine lamination temperature profiles, enhance data accuracy and provide insights into optimal process control for uniform module lamination. Ensuring consistent and uniform lamination may improve the accuracy and reliability of research outcomes.

14 SOLAR ENERGY↗

TEMPEST (Thermo-Electric Model for Powering Energy Storage Technologies)

NREL's TEMPEST model combines electrical and thermal modeling for residential-scale battery systems. The model and default parameters are based off of two common commercial residential batteries. Key inputs to the model include house load, temperature of the battery location, and the solar profile. The key output of the TEMPEST model is the battery profile and internal battery temperature. If internal battery temperature exceeds limits, a derating will occur and this will be reflected in the battery profile. In addition to thermal modeling, the TEMPEST model uses realistic operating principals that are common in today's residential batteries. Mainly, the TEMPEST model incorporates "modes" of operation that constrain battery setpoint based on house load, solar output, and state of charge. The TEMPEST model can be used to analyze the effect of battery temperature, deratings, and mode setpoints on utility network loading and customer bills.

Blonsky, Michael↗

D retention and depth profile behavior for single crystal tungsten with high temperature neutron irradiation

Single crystalline W (tungsten) samples irradiated at 633, 963 and 1073 K by neutrons to a damage level of 0.1 dpa were exposed to a high-flux D (deuterium) plasma at 673, 873 and 973 K, respectively, in TPE (Tritium Plasma Experiment) at INL (Idaho National Laboratory). Deuterium desorption was analyzed by TDS (Thermal Desorption Spectroscopy), and D depth profiles were determined by NRA (Nuclear Reaction Analysis) at SNL (Sandia National Laboratories). HIDT (Hydrogen Isotope Diffusion and Trapping) simulation code was applied to evaluate D behavior for neutron-damaged W at higher temperature. The D retention at depths up to 3 f.tm for the neutron-damaged sample at 673 K was two orders of magnitude larger than that for undamaged tungsten, and its D desorption spectrum had a single broad stage at around 900 K. As the neutron irradiation/plasma exposure temperature increased, D retention was largely reduced, and the desorption temperature was increased to higher temperatures above 1100 K. The D depth profiles by NRA also showed D migration toward bulk by higher temperature irradiation, compared to undamaged W. The HIDT simulation indicated that the major binding energy of D was changed from 1.43 eV to 2.07 eV at higher neutron irradiation and plasma exposure temperatures, suggesting that some vacancies and small vacancy clusters would aggregate to form larger voids, or depopulation of weak traps at high D plasma exposure temperatures. It can be said that more stable trapping sites played dominant roles in the D retention at higher neutron irradiation and plasma exposure temperature. The binding energy by HIDT simulation was almost consistent with the reported value by TMAP, but the consideration of not only total D retention measured by TDS but also D depth profile by NRA led to the more accurate D behavior in neutron-damaged W.

36 MATERIALS SCIENCE↗

TEM turbulence in simulation and experiment in quasisymmetric and degraded-symmetry configurations of the HSX stellarator

The Helically Symmetric Experiment (HSX) has demonstrated reduced neoclassical transport and flow damping with quasisymmetry, but the difference of turbulent transport between quasisymmetric and degraded-symmetry configurations has not been definitively assessed. Profile analysis presented here shows that anomalous transport at the mid-radius is larger with degraded quasisymmetry when temperature and density profiles are matched. An initial comparison (${T_\mathrm{i}/T_\mathrm{e}} = 1$) between the quasisymmetric and degraded symmetry configurations finds that trapped-electron mode (TEM) turbulence can support larger heat fluxes in the degraded symmetry configuration despite smaller linear growth rates. However, further simulations at the experimental temperature ratio ($T_\mathrm{i}/T_\mathrm{e} = 0.2$) do not reproduce this effect. Experimental measurements of heat transport and density fluctuation amplitude are compared to nonlinear gyrokinetic simulations at the experimental temperature ratio. The heat flux and density fluctuation amplitude in simulation reproduce a substantial dependence on the density gradient, and the simulated heat flux matches measurements within experimental uncertainties, indicating that TEM turbulence is responsible for the anomalous transport at the steep density gradient in HSX.

HSX↗

Neural-Network-Enhanced COTSIM: Advancing Predictive Capabilities for Fast DIII-D Simulations

Sustaining fusion reactions in tokamaks requires heating plasma to thermonuclear temperatures while maintaining confinement and stability. Neutral beam injection (NBI) provides heating, current drive, torque, and fueling, while electron cyclotron (EC) waves are widely used for heating and current drive; together, these actuators shape the plasma current, temperature, and density profiles. The control-oriented tokamak simulator (COTSIM), a predictive, control-oriented code, has been enhanced with neural-network surrogates for transport and sources. Turbulent transport is predicted by MMMnet—a neural-network version of the updated multimode model (MMM 9.0.10)—with significantly reduced computation time relative to MMM; neoclassical transport follows the Chang–Hinton model. NUBEAMnet, a surrogate of the Monte Carlo NUBEAM module, predicts beam-driven heating, current, and torque. EC heating and current drive use a control-oriented, empirically scaled source model; plasma resistivity follows the Spitzer formulation; bootstrap current uses the Sauter model. Equilibrium is computed using both prescribed and fixed-boundary solvers (FBSs), and the pedestal structure is modeled with an empirical pedestal model. For a representative DIII-D discharge, COTSIM predicts electron and ion temperature and safety-factor profiles in close agreement with TRANSP predictive and interpretive simulations while extending predictions through the pedestal region to the plasma edge (versus 80% of the minor radius in TRANSP). Furthermore, the equivalent COTSIM simulation runs in under 3 min compared to about 2 h for TRANSP, enabling rapid scenario planning, optimization of tokamak operation, and between-pulse control design.

Control-oriented tokamak simulator (COTSIM)↗

Evaluation of liquid-phase thermometry in impinging jet sprays using synchrotron x-ray scattering

Liquid thermometry during primary and secondary breakup of liquid sprays is challenging due to the presence of highly dynamic, optically complex flow features. This work evaluates the use of x-ray scattering from a focused, monochromatic beam of the Advanced Photon Source at Argonne National Laboratory for the measurement of liquid temperatures within the mixing zone of an impinging jet spray. The measured scattering profiles are converted to temperature through a previously developed two-component partial least squares (PLS) regression model. Transmitive mixing during jet merging is inferred through spatial mapping of temperatures within the impingement region. In this work, the technique exhibits uncertainties of ±2K in temperature and 2% in capturing the correct scattering profile, showing its potential utility for probing liquid temperature distributions in multiphase flows.

42 ENGINEERING↗

Kinetic and temperature sensitivity properties of soil exoenzymes through the soil profile down to one-meter depth at a temperate coniferous forest (Blodgett, CA)

This dataset contains data on kinetic and temperature sensitivity parameters of the exoenzymes β-glucosidase (BG), leucine/leucyl aminopeptidase (LAP) and acid phosphatase (AP) across a soil profile down to 90 cm depth at Blodgett forest, CA, USA. These data were generated to determine if kinetic and thermal properties of microbial exoenzymes involved in organic matter decomposition varied with soil depth, following variation in soil properties and microbial communities, as part of the study: Alves et al. (2021). Kinetic Properties of Microbial Exoenzymes Vary with Soil Depth but Have Similar Temperature Sensitivities Through the Soil Profile. Frontiers in Microbiology 12:3618. https://doi.org/10.3389/fmicb.2021.735282. This research was performed within the framework of the TES Belowground Biogeochemistry SFA project, in particular association with a long-term field warming experiment of the whole soil profile at Blodgett forest. Samples for this work were collected from locations representative of the field experimental plots. Potential enzyme activity rates were measured using laboratory fluorometric assays with soils collected at 0-10, 10-20, 30-40, 50-60, 60-70 and 80-90 cm deep in biological triplicates (i.e., three soil cores collected at different representative locations). Assays with each soil were conducted over a gradient of eight substrate concentrations per enzyme, and incubated at 4, 10, 16, 25, 35 or 50°C. Enzyme Michaelis-Menten kinetics were modeled over the eight substrate concentrations at each temperature, and the temperature sensitivity of the kinetic parameters was modeled over the six temperatures using linear Arrhenius/Q10 and non-linear Macromolecular Rate Theory (MMRT) models. The dataset includes the fully processed enzyme activity rate data used to model Michaelis-Menten kinetics, calculated kinetic and temperature sensitivity parameters, and basic soil and microbial biomass chemistry for each sample. All data is provided for each individual biological replicate, and kinetic and temperature sensitivity parameters are also provided as means of the biological replicates. The dataset also includes all raw measurement data and code used to parse, combine and perform the analyses described by Alves et al. (2021). For file descriptions, see the file-level metadata files: “enzymes_dataProcessed_flmd.xlsx” (processed data); “enzymes_dataRaw_flmd.xlsx” (compressed raw data and metadata); and “enzymes_code_flmd.xlsx” (compressed code). The experimental design, list of parameters measured, soil and microbial biomass chemistry data, and means of biological replicates for kinetic and temperature sensitivity parameters are also provided as human-readable tables in file “enzymeTraits_design_results_tables.xlsx”.

54 ENVIRONMENTAL SCIENCES↗

Multi-scale transport in the DIII-D ITER baseline scenario with direct electron heating and projection to ITER

Multi-scale fluctuations measured by turbulence diagnostics spanning long and short wavelength spatial scales impact energy confinement and the scale-lengths of plasma kinetic profiles in the DIII-D ITER baseline scenario with direct electron heating. Contrasting discharge phases with ECH + neutral beam injection (NBI) and NBI only at similar rotation reveal higher energy confinement and lower fluctuations when only NBI heating is used. Modeling of the core transport with TGYRO using the TGLF turbulent transport model and NEO neoclassical transport reproduces the experimental profile changes upon application of direct electron heating and indicates that multi-scale transport mechanisms are responsible for changes in the temperature and density profiles. Intermediate and high-k fluctuations appear responsible for the enhanced electron thermal flux, and intermediate-k electron modes produce an inward particle pinch that increases the inverse density scale length. Projection to ITER is performed with TGLF and indicates a density profile that has a finite scale length due to intermediate-k electron modes at low collisionality and increases the fusion gain. For a range of E×B shear, the dominant mechanism that increases fusion performance is suppression of outward low-k particle flux and increased density peaking.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Operation above the Greenwald density limit in high performance DIII-D negative triangularity discharges

The density limit in strongly-shaped negative triangularity (NT) discharges is studied experimentally in the DIII-D tokamak. Record-high Greenwald fractions f G are obtained, using gas puff injection only, with values up to near 2, where f G is defined as the ratio of the line-averaged density over n G = I p /(π a 2 ), with I p [MA] the plasma current and a[m] the plasma minor radius. A clear higher operational limit with higher auxiliary power is also demonstrated, with the ohmic density limit about two times lower than with additional neutral beam injection heating. The evolution of the electron density, temperature and pressure profiles are analyzed as well. The core density can be up to twice the Greenwald density and keeps increasing, while the value at the separatrix remains essentially constant and slightly below n G . The edge temperature gradient collapses to near zero and NT plasmas are shown to be resilient to such profiles in terms of disruptivity. We also present the time evolution of the inverse electron pressure scale length with the value at the last closed flux surface (LCFS) decreasing below the value at the normalized radius 0.9 near the density limit, demonstrating the clear drop of confinement starting from the edge. This inverse scale length ‘collapse’ at the LCFS also defines well the characteristic behavior of the kinetic profiles approaching a density limit.

density limit↗

Numerical Investigation of Wall-Cooling Effect on Aero-Optical Distortions for Hypersonic Boundary Layer

Compressible wall-modeled large-eddy simulations of Mach 8 turbulent boundary-layer flows over a flat plate were carried out for the conditions of the hypersonic wind tunnel at Sandia National Laboratories. The simulations provide new insight into the effect of wall cooling on the aero-optical path distortions for hypersonic turbulent boundary-layer flows. Four different wall-to-recovery temperature ratios, 0.3, 0.48, 0.71, and 0.89, are considered. Despite the much lower grid resolution, the mean velocity, temperature, and resolved Reynolds stress profiles from the simulation for a temperature ratio of 0.48 are in good agreement with those from a reference direct numerical simulation. The normalized root-mean-square optical path difference obtained from the present simulations is compared with that from reference direct numerical simulations, Sandia experiments, as well as predictions obtained with a semi-analytical model by Notre Dame University. Here the present analysis focuses on the effect of wall cooling on the wall-normal density correlations, on key underlying assumptions of the aforementioned model such as the strong Reynolds analogy, and on the elevation angle effect on the optical path difference. Wall cooling is found to increase the velocity fluctuations and decrease the density fluctuations, resulting in an overall reduction of the normalized optical path distortion. Compared to the simulations, the basic strong Reynolds analogy overpredicts the temperature fluctuations for cooled walls. Also different from the strong Reynolds analogy, the velocity and temperature fluctuations are not perfectly anticorrelated. Finally, as the wall temperature is raised, the density correlation length, away from the wall but inside the boundary layer, increases significantly for beam paths tilted in the downstream direction.

42 ENGINEERING↗

Dynamic Subgrid Turbulence Modeling for Shallow Cumulus Convection Simulations beyond LES Resolutions

A scale-dependent dynamic Smagorinsky model is implemented in the Met Office/NERC Cloud (MONC) model using two averaging flavors, along Lagrangian pathlines and local moving averages. The dynamic approaches were compared against the conventional Smagorinsky–Lilly scheme in simulating the diurnal cycle of shallow cumulus convection. The simulations spanned from the LES to the near-gray-zone and gray-zone resolutions and revealed the adaptability of the dynamic model across the scales and different stability regimes. The dynamic model can produce a scale- and stability-dependent profile of the subfilter turbulence length scale across the chosen resolution range. At gray-zone resolutions the adaptive length scales can better represent the early precloud boundary layer leading to temperature and moisture profiles closer to the LES compared to the standard Smagorinsky. As a result, the initialization and general representation of the cloud field in the dynamic model is in good agreement with the LES. In contrast, the standard Smagorinsky produces a less well-mixed boundary layer, which fails to ventilate moisture from the boundary layer, resulting in the delayed spinup of the cloud layer. Moreover, strong downgradient diffusion controls the turbulent transport of scalars in the cloud layer. However, the dynamic approaches rely on the resolved field to account for nonlocal transports, leading to overenergetic structures when the boundary layer is fully developed and the Lagrangian model is used. Introducing the local averaging version of the model or adopting a new Lagrangian time scale provides stronger dissipation without significantly affecting model behavior.

54 ENVIRONMENTAL SCIENCES↗

Implementation of low temperature spectrometers for the JET high resolution Thomson scattering diagnostic for disruption plasma measurements

This work presents a system upgrade of the High Resolution Thomson Scattering (HRTS) diagnostic on JET that allows it to measure low temperature (1–500 eV) plasma pre- and post-Thermal quench (TQ), which would help us further understand the Shattered Pellet Injection (SPI) physics. The upgrade was done by connecting optic fibers from the original HRTS system to four spectrometers specialized in measuring low temperature plasmas. The upgraded system allows for the measurement of low temperature plasma at up to 12 spatial points, which can be flexibly distributed throughout the JET outer midplane profile during the dedicated SPI experiments. In other JET experiments, four previously unused groups of fibers were used to measure the central plasma to provide disruption data without changing the standard HRTS system. The low temperature Thomson scattering system was installed, commissioned, and cross-calibrated against the standard HRTS diagnostic in a calibration pulse. The system worked reliably during the JET experiments and provided electron density and temperature profiles for pre- and post-TQ low temperature plasmas in the SPI campaign.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An ICA-Based HVAC Load Disaggregation Method Using Smart Meter Data

This paper presents an independent component analysis (ICA) based unsupervised-learning method for heat, ventilation, and air-conditioning (HVAC) load disaggregation using row-resolution (i.e., 15 minutes) smart meter data. We first demonstrate that the electricity consumption profiles on mild-temperature days can be used to approximate the base load on hot days. A residual load profile can then be calculated by subtracting the mild-day load profile from the hot-day load profile. The residual load profiles are processed using ICA for HVAC load extraction. An optimization-based algorithm is proposed for post-adjustment of the ICA results, considering two bounding factors for enhancing the robustness of the ICA algorithm. First, we use the hourly HVAC energy bounds computed from the relationship between HVAC load and temperature to remove unrealistic HVAC load spikes. Second, we exploit the dependency between the daily nocturnal and diurnal loads extracted from historical meter data to smooth the base load profile. Pecan Street data with sub-metered HVAC data were used to test and verify the proposed methods. Simulation results demonstrated that the proposed method is computationally efficient and robust across multiple customers.

Kim, Hyeonjin↗

Gyrokinetic simulation of turbulence and transport in the SPARC tokamak

The turbulence and transport expected in the SPARC tokamak Primary Reference Discharge (PRD) [P. Rodriguez-Fernandez et al., J. Plasma Phys. 86, 865860503 (2020)] have been investigated with the gyrokinetic code CGYRO [J. Candy et al., J. Comput. Phys. 324, 73–93 (2016)]. Linear and nonlinear simulations that focus on ion (kθρs<1.0) and electron-scale (kθρs>1.0) turbulence were used to probe the nature of the turbulence and the resulting transport in the fusion core. It is found that in the SPARC PRD, ion temperature gradient (ITG) turbulence is expected to dominate transport over most of the profile with some potential trapped electron mode impact in the near edge. Stiff turbulence is observed over a part of the plasma core such that SPARC's ion temperature profile will likely be pinned to just above the critical gradient for ITG. The role of electromagnetic turbulence, rotation, and electron-scale turbulence was investigated to provide some insight into the physics required to accurately predict SPARC performance via gyrokinetics. Additionally, predictions of impurity peaking for potential low- and high-Z SPARC first-wall materials are probed using ion-scale simulation. The dominance of low-k turbulence in SPARC provides a potential opportunity for more tractable prediction of plasma profiles using nonlinear gyrokinetics. This work is the first step toward full gyrokinetic profile prediction of SPARC kinetic profiles and the resulting fusion power and plasma gain.

Howard, N. T. (ORCID:0000000287876309)↗

Optimal sensor network design for multi-scale, time-varying differential algebraic equation systems: Application to an entrained-flow gasifier refractory brick

An algorithm for optimal sensor network design for multi-scale, time-varying differential algebraic equation systems with non-separable dynamics is presented. As the process is time-varying, an integral normalized posterior error covariance of a multi-scale filter is minimized to obtain the optimal sensor locations. For reducing the computational cost, an adaptive sampling rate approach is considered for the slowly-varying variables. The algorithm is applied to a smart refractory brick with embedded sensors as part of an entrained-flow gasifier. Thermistors and interdigital capacitors are considered as candidate measurement technologies for estimating temperature and slag penetration profile along the gasifier wall. Finally, when the optimal set of sensors obtained from the algorithm is used for estimating temperature and slag penetration profiles in a multi-scale Kalman filter framework, satisfactory estimates are obtained despite high measurement noise and model mismatch.

42 ENGINEERING↗

Dynamic evolution of ultracold electron beams from nanostructured cathodes

Dynamic Coulomb expansion of dense, nonuniform particle beamlets can lead to causticlike formations in the charge density profile of the resultant beam. Such features only occur for cold beams where thermal diffusion of the particles is minimized. These phenomena have been observed experimentally for select cases with ion beams but not yet for electron beams as the electron dynamics occur over far faster timescales. We simulate the interaction of electron bunches while varying the initial transverse temperature and density profiles to determine the thresholds that characterize this pattern formation. Furthermore, we extend the simulations to geometric arrangements that are more pertinent to the nanotip cathode application and consider the effects of asymmetries and the impact of a low-density halo on the overall process. The simulations are conducted using a previously documented high-fidelity algorithm for collisional particle dynamics. These studies identify the temperature and density thresholds required for caustic formation and provide guidance for optimizing the design of nanoscale structured cathodes. We also demonstrate that the correlation between the final density patterns and the underlying beam parameters enables a virtual diagnostic tool for measuring ultralow emittance beams solely based on a transverse charge density profile.

43 PARTICLE ACCELERATORS↗

Improved method for temporally interpolating radiosonde profiles in the convective boundary layer

A significantly improved technique for temporally interpolating radiosonde (RS) profiles of potential temperature and water vapor mixing ratio in the planetary boundary layer during daytime is introduced. The key innovation of this technique is its operation on a height grid normalized with the planetary boundary layer height. This study utilized a three-month dataset of three-hourly soundings from the Atmospheric Radiation Measurement Facility's Southern Great Plains site. The technique was evaluated for convective boundary layer cases, with the necessary boundary layer height data obtained from a ground-based infrared spectrometer. A total of 79 comparisons were conducted between reference soundings and interpolated profiles that did and did not employ height normalization. The results demonstrated a substantial improvement in the representation of interpolated profiles using the new technique, characterized by enhanced correlation, improved amplitude representation, and reduced bias for potential temperature, as well as improved correlation and reduced bias for water vapor mixing ratio.

convective boundary layer↗

Enhancing $\phi$-sensitivity of ignition delay times through dilution of fuel-air mixture

The high $\phi$-sensitivity (η) of ignition delay time (τ IDT ) is one of the desirable fuel properties for the high-load extension of advanced compression ignition engine. Recent studies revealed the effectiveness of a high dilution rate (x D ) for enhancing η at the engine-relevant conditions. This study aims to quantify the effect of dilution on the η of isooctane using a combined experiment-simulation approach. The ignition delay of the isooctane/air mixture was measured with an Advanced Fuel Ignition Delay Analyzer (AFIDA) over the temperature range of 623 - 923 K at 10 bar pressure with global $\phi$ = 0.3 - 0.6, with and without 28.6% of additional N 2 dilution. For precise evaluation of experimental η, the facility effect of the AFIDA experiment was characterized with three-dimensional computational fluid dynamics (3-D CFD) simulation. The temperature in the combustion chamber from 3-D CFD indicated a substantial temporal dependency, varying up to ~52 K by charge-cooling of fuel injection and heat transfer from the wall. We introduced the dimensionless number θ(t) for characterizing the temporal profile of chamber temperature. Consideration of the facility effect using θ(t) resulted in better agreement between the experimental ..eta.. and zero-dimensional (0-D) kinetics simulation. The refined η were then further utilized to quantify the effectiveness of dilution to η The extent of η enhancement with dilution strategy was maximized at the low-temperature chemistry regime, increasing η by 77% with a 28.6% dilution rate. Further analysis on the dilution effect was carried out using 0-D kinetics simulation, revealing the critical dimensionless numbers relevant to the effectiveness of dilution to η enhancement. Here, this study is the first experiment-simulation combined research to quantify the effect of dilution on η, facilitating the kinetics model refinement for better reproduction of $\phi$-sensitivity.

33 ADVANCED PROPULSION SYSTEMS↗