Search NASA⌕ Search

SEARCH · Search NASA

Results for “threshold based”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

The Renewable Fuel Standard May Limit Overall Greenhouse Gas Savings by Corn Stover-Based Cellulosic Biofuels in the U.S. Midwest: Effects of the Regulatory Approach on Projected Emissions

The Renewable Fuel Standard (RFS) program specifies a greenhouse gas (GHG) reduction threshold for cellulosic biofuels, while the Low Carbon Fuel Standard (LCFS) program in California does not. Here, we investigate the effects of the GHG threshold under the RFS on projected GHG savings from two corn stover-based biofuel supply chain systems in the United States Midwest. The analysis is based on a techno-economic framework that minimizes ethanol selling price. The GHG threshold lowers the lifecycle GHG of ethanol: 34.39 +/- 4.92 gCO(2) MJ(-1) in the RFS-compliant system and 46.30 +/- 10.05 gCO(2) MJ1 in the non RFS-compliant system. However, hypothetical biorefinery systems complying with the RFS will not process the more GHG-intensive corn stover, and thus much less biofuel will be produced compared to the non RFS-compliant system. Thus, taken as a whole, the non RFS-compliant system would achieve more GHG savings than an RFS-compliant system: 10.7 TgCO(2) year(-1) in the non RFS-compliant system compared with 4.4 TgCO(2) year1 in the RFS-compliant system. These results suggest that the current RFS GHG reduction threshold may not be the most efficient way to carry out the purposes of the Energy Security and Independence Act in the corn stover-based biofuel system: relaxing the threshold could actually increase the overall GHG savings from corn stover-based biofuels. Therefore, the LCFS-type regulatory approach is recommended for the corn stover-based cellulosic biofuel system under the RFS program. In addition, our calculation of the GHG balance for stover-based biofuel accounts for SOC losses, while the current RFS estimates do not include effects on SOC.

CARBON, BIOMASS, VOLUME↗

Lead-chalcogenide mid-infrared vertical external cavity surface emitting lasers with improved threshold: Theory and experiment

Mid-infrared Vertical External Cavity Surface Emitting Lasers (VECSEL) based on narrow gap lead-chalcogenide (IV-VI) semiconductors exhibit strongly reduced threshold powers if the active layers are structured laterally for improved optical confinement. This is predicted by 3-d optical calculations; they show that lateral optical confinement is needed to counteract the anti-guiding features of IV-VIs due to their negative temperature dependence of the refractive index. An experimental proof is performed with PbSe quantum well based VECSEL grown on a Si-substrate by molecular beam epitaxy and emitting around 3.3 μm. With proper mesa-etching, the threshold intensity is about 8-times reduced.

36 MATERIALS SCIENCE↗

2005 ACGIH Lifting TLV: Employee-Friendly Presentation and Guidance for Professional Judgment

The American Council of Governmental Industrial Hygienists (ACGIH) Lifting Threshold Limit Values (TLVs) provide a tool to reduce incidence of low back and shoulder injuries. However, application of the TLV is too complicated for floor-level workers and relies on professional judgment to assess commonly encountered tasks. This paper presents an Employee-Friendly Simplified Format of the TLV that has been adapted from Table 1 of the Lifting TLV presented in the 2005 TLVs and BEIs Based on the Documentation of the Threshold Limit Values for Chemical Substances and Physical Agents & Biological Exposure Indices. This simplified format can be employed by floor-level workers to self-assess lifting tasks. The Ergonomics Project Team also provides research-based guidance for applying professional judgment consistent with standard industry practice: Extended Work Shifts – Reduce weight by 20% for shifts lasting 8 to 12 hours; Constrained Lower Body Posture – Reduce weight by 25% when lifting in such postures; Infrequently Performed Lifts – Lift up to 15 lbs. ≤3 lifts per hour within the zones marked “No safe limit for repetitive lifting” in the TLVs Table 1; Asymmetry beyond 30° – Reduce weight by 10 lbs. for lifts with up to 60° asymmetry from sagittal plane.

60 APPLIED LIFE SCIENCES↗

A fully 3D atomistic quantum mechanical study on random dopant induced effects in 25nm MOSFETs

We present a fully 3D atomistic quantum mechanical simulation for nanometered MOSFET using a coupled Schroedinger equation and Poisson equation approach. Empirical pseudopotential is used to represent the single particle Hamiltonian and linear combination of bulk band (LCBB) method is used to solve the million atom Schroedinger's equation. We studied gate threshold fluctuations and threshold lowering due to the discrete dopant configurations. We compared our results with semiclassical simulation results. We found quantum mechanical effects increase the threshold fluctuation while decreases the threshold lowering. The increase of threshold fluctuation is in agreement with previous study based on approximated density gradient approach to represent the quantum mechanical effect. However, the decrease in threshold lowering is in contrast with the previous density gradient calculations.

36 MATERIALS SCIENCE↗

Scattering assisted injection based injectorless mid infrared quantum cascade laser

An injectorless five-well mid infrared quantum cascade laser is analyzed which relies on phonon scattering injection in contrast to resonant tunneling injection, which has been previously used for injectorless designs. A Monte Carlo based self-consistent electron and photon transport simulator is used to analyze the performance of the analyzed design and compare it to existing injectorless designs. The simulation results show that the analyzed design could greatly enhance the optical gain and the characteristic temperatures of injectorless quantum cascade lasers (QCLs) which have typically been hindered by low characteristic temperatures and significant temperature related performance degradation. Simulations of the analyzed device predict threshold current densities of 0.85 kA/cm{sup 2} and 1.95 kA/cm{sup 2} at 77 K and 300 K, respectively, which are comparable to the threshold current densities of conventional injector based QCLs.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Bayesian estimation of dose thresholds

An example is described of Bayesian estimation of radiation absorbed dose thresholds (subsequently simply referred to as dose thresholds) using a specific parametric model applied to a data set on mice exposed to 60Co gamma rays and fission neutrons. A Weibull based relative risk model with a dose threshold parameter was used to analyse, as an example, lung cancer mortality and determine the posterior density for the threshold dose after single exposures to 60Co gamma rays or fission neutrons from the JANUS reactor at Argonne National Laboratory. The data consisted of survival, censoring times and cause of death information for male B6CF1 unexposed and exposed mice. The 60Co gamma whole-body doses for the two exposed groups were 0.86 and 1.37 Gy. The neutron whole-body doses were 0.19 and 0.38 Gy. Marginal posterior densities for the dose thresholds for neutron and gamma radiation were calculated with numerical integration and found to have quite different shapes. The density of the threshold for 60Co is unimodal with a mode at about 0.50 Gy. The threshold density for fission neutrons declines monotonically from a maximum value at zero with increasing doses. The posterior densities for all other parameters were similar for the two radiation types.

NASA Discipline Radiation Health↗

Resonance Suppression based on Predictive Control of Grid-following Inverters with LCL Filter in Weak Grid Condition

This paper presents an effective resonance suppression control when grid interactive inverter with LCL filter experience weak grid conditions. The resonance suppression mechanism is based on finite-set model predictive control (FSMPC) with adaptive cost function to alter the controller objectives seamlessly. The large parasitic impedance and low short circuit ratio (SCR) of weak grid challenges the operation of gridconnected inverters. Specifically, the LCL filter resonance may get excited, resulting in collapse of the inverter operation. To address this issue, an effective active damping approach is implemented in the proposed control. In the proposed active damping scheme for resonance suppression, the feedback currents are switched based on the operating conditions of inverter. During the stiff grid conditions, grid current serves as feedback to the controller. While in the weak grid conditions, the inverter current is selected as feedback signal. The toggling action between these two feedback currents is determined by comparing moving RMS of grid current with threshold current as constraint in the cost function of the proposed MPC scheme. The threshold current for toggling action is based on the reference active and reactive power setpoints plus an acceptable band of variation. The theoretical analysis is verified by several case studies.

Umar, Muhammad Farooq↗

Integrated unaligned resonant modulator tuning

Methods and systems for tuning a resonant modulator are disclosed. One method includes receiving a carrier signal modulated by the resonant modulator with a stream of data having an approximately equal number of high and low bits, determining an average power of the modulated carrier signal, comparing the average power to a predetermined threshold, and operating a tuning device coupled to the resonant modulator based on the comparison of the average power and the predetermined threshold. One system includes an input structure, a plurality of processing elements, and a digital control element. The input structure is configured to receive, from the resonant modulator, a modulated carrier signal. The plurality of processing elements are configured to determine an average power of the modulated carrier signal. The digital control element is configured to operate a tuning device coupled to the resonant modulator based on the average power of the modulated carrier signal.

42 ENGINEERING↗

Probing the cosmic gamma-ray burst rate with trigger simulations of the swift burst alert telescope

The gamma-ray burst (GRB) rate is essential for revealing the connection between GRBs, supernovae, and stellar evolution. Additionally, the GRB rate at high redshift provides a strong probe of star formation history in the early universe. While hundreds of GRBs are observed by Swift, it remains difficult to determine the intrinsic GRB rate due to the complex trigger algorithm of Swift. Current studies of the GRB rate usually approximate the Swift trigger algorithm by a single detection threshold. However, unlike the previously flown GRB instruments, Swift has over 500 trigger criteria based on photon count rate and an additional image threshold for localization. To investigate possible systematic biases and explore the intrinsic GRB properties, we develop a program that is capable of simulating all the rate trigger criteria and mimicking the image threshold. Our simulations show that adopting the complex trigger algorithm of Swift increases the detection rate of dim bursts. As a result, our simulations suggest that bursts need to be dimmer than previously expected to avoid overproducing the number of detections and to match with Swift observations. Moreover, our results indicate that these dim bursts are more likely to be high redshift events than low-luminosity GRBs. This would imply an even higher cosmic GRB rate at large redshifts than previous expectations based on star formation rate measurements, unless other factors, such as the luminosity evolution, are taken into account. The GRB rate from our best result gives a total number of 4568{sub −1429}{sup +825} GRBs per year that are beamed toward us in the whole universe.

79 ASTRONOMY AND ASTROPHYSICS↗

Transcript and blood-microbiome analysis towards a blood diagnostic tool for goats affected by Haemonchus contortus

The Alpine goat (Capra aegagrus hircus) is parasitized by the barber pole worm (Haemonchus contortus). Hematological parameters from transcript and metagenome analysis in the host are reflective of infestation. We explored comparisons between blood samples of control, infected, infected zoledronic acid-treated, and infected antibody (anti-γδ T cells) treated wethers under controlled conditions. Seven days post-inoculation (dpi), we identified 7,627 transcripts associated with the different treatment types. Microbiome measurements at 7 dpi revealed fewer raw read counts across all treatments and a less diverse microbial flora than at 21 dpi. This study identifies treatment specific transcripts and an increase in microflora abundance and diversity as wethers age. Further, F/B ratio reflect health, based on depression or elevation above thresholds defined by the baseline of non-infected controls. Forty Alpine wethers were studied where blood samples were collected from five goats in four treatment groups on 7 dpi and 21 dpi. Transcript and microbiome profiles were obtained using the Partek Flow (St. Louis, Missouri, USA) software suites pipelines. Inflammation comparisons were based on the Firmicutes/Bacteriodetes ratios that are calculated as well as the reduction of microbial diversity.

60 APPLIED LIFE SCIENCES↗

SETI Pulse Detection Algorithm: Analysis of False-alarm Rates

Some earlier work by the Search for Extraterrestrial Intelligence (SETI) Science Working Group (SWG) on the derivation of spectrum analyzer thresholds for a pulse detection algorithm based on an analysis of false alarm rates is extended. The algorithm previously analyzed was intended to detect a finite sequence of i periodically spaced pulses that did not necessarily occupy the entire observation interval. This algorithm would recognize the presence of such a signal only if all i-received pulse powers exceeded a threshold T(i): these thresholds were selected to achieve a desired false alarm rate, independent of i. To simplify the analysis, it was assumed that the pulses were synchronous with the spectrum sample times. This analysis extends the earlier effort to include infinite and/or asynchronous pulse trains. Furthermore, to decrease the possibility of missing an extraterrestrial intelligence signal, the algorithm was modified to detect a pulse train even if some of the received pulse powers fall below the threshold. The analysis employs geometrical arguments that make it conceptually easy to incorporate boundary conditions imposed on the derivation of the false alarm rates. While the exact results can be somewhat complex, simple closed form approximations are derived that produce a negligible loss of accuracy.

Levitt, B. K.↗

A phenomenological model on the kink mode threshold varying with the inclination of sheath boundary

In nature and many laboratory plasmas, a magnetic flux tube threaded by current or a flux rope has a footpoint at a boundary. The current driven kink mode is one of the fundamental ideal magnetohydrodynamic instabilities in plasmas. It has an instability threshold that has been found to strongly depend on boundary conditions (BCs). We provide a theoretical model to explain the transition of this threshold dependence between nonline tied and line tied boundary conditions. We evaluate model parameters using experimentally measured plasma data, explicitly verify several kink eigenfunctions, and validate the model predictions for boundary conditions BCs that span the range between NLT and LT BCs. Based on this model, one could estimate the kink threshold given knowledge of the displacement of a flux rope end, or conversely estimate flux rope end motion based on knowledge of it kink stability threshold.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Cost-Effectiveness Analysis of Intensity Modulated Radiation Therapy Versus 3-Dimensional Conformal Radiation Therapy for Preoperative Treatment of Extremity Soft Tissue Sarcomas

Purpose: Create a cost-effectiveness model comparing preoperative intensity modulated radiation therapy (IMRT) versus 3-dimensional conformal radiation therapy (3DCRT) for extremity soft tissue sarcomas. Methods and Materials: Input parameters included 5-year local recurrence rates, rates of acute wound adverse events, and chronic toxicities (edema, fracture, joint stiffness, and fibrosis). Health-state utilities were used to calculate quality-adjusted life years (QALYs). Overall treatment costs per QALY or incremental cost-effectiveness ratio (ICER) were calculated. Roll-back analysis was performed using average costs and utilities to determine the baseline preferred radiation technique. One-way, 2-way, and probabilistic sensitivity analyses (PSA) were performed for input parameters with the largest impact on the ICER. Results: Overall treatment costs were $17,515.58 for 3DCRT compared with $22,920.51 for IMRT. The effectiveness was higher for IMRT (3.68 QALYs) than for 3DCRT (3.35 QALYs). The baseline ICER for IMRT was $16,842.75/QALY, making it the preferable treatment. The ICER was most sensitive to the probability of local recurrence, upfront radiation costs, local recurrence costs, certain utilities (no toxicity/no recurrence, grade 1 toxicity/no local recurrence, grade 4 toxicity/no local recurrence), and life expectancy. Dominance patterns emerged when the cost of 3DCRT exceeded $15,532.05 (IMRT dominates) or the life expectancy was under 1.68 years (3DCRT dominates). Furthermore, preference patterns changed based on the rate of local recurrence (threshold: 13%). The PSA results demonstrated that IMRT was the preferred cost-effective technique for 64% of trials compared with 36% for 3DCRT. Conclusions: Based on our model, IMRT is the preferred technique by lowering rates of local recurrence, severe toxicities, and improving QALYs. From a third-party payer perspective, IMRT should be a supported approach for extremity soft tissue sarcomas.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Testing and signal identification for two-sample high-dimensional covariances via multi-level thresholding

The paper considers testing and signal identification for covariance matrices from two populations of marginally sub-Gaussian distributed. A multi-level thresholding procedure is proposed for testing the equality of two high-dimensional covariance matrices, which is designed to detect sparse and faint differences between the covariances. A novel -statistic composition is developed to establish the asymptotic distribution of the thresholding statistics in conjunction with the matrix blocking and the coupling techniques. It is shown that the proposed test is more powerful than the existing tests in detecting sparse and weak signals in covariances. Multiple testing procedures are constructed to discover different covariances and the sub-groups of variables with different covariance structures between the two populations. The proposed procedures are based on the multi-level thresholding test, which are able to control the false discovery proportion () with high power. Simulation experiments and a case study on the returns of the S&P 500 stocks before and after the COVID-19 pandemic are conducted to demonstrate and compare the utilities of the proposed methods.

97 MATHEMATICS AND COMPUTING↗

A critical evaluation of the NCRP COMMENTARY 27 endorsement of the linear no-threshold model of radiation effects

Highlights: • The linear no-threshold (LNT) model of radiation effects has fractured the scientific community. • This paper analyzes the latest review of the LNT model, NCRP Commentary 27. • Expert reviews of the LNT model rely on institutional inertia and numerous logical fallacies. • Recommendations to advance this debate in an objective future review are provided. Regulatory policy to protect the public and the environment from radiation is universally based on the linear, no-threshold model (LNT) of radiation effects. This model has been controversial since its inception over nine decades ago, and remains so to this day, but it has proved remarkably resistant to challenge from the scientific community. The LNT model has been repeatedly endorsed by expert advisory bodies, and regulatory agencies in turn adopt policies that reflect this advice. Unfortunately, these endorsements rest on a foundation of institutional inertia and numerous logical fallacies. These include most significantly setting the LNT as the null hypothesis, and shifting the burden of proof onto LNT skeptics. Other examples include arbitrary exclusion of alternative hypotheses, ignoring criticisms of the LNT, cherry-picking evidence, and making policy judgements without foundation. This paper presents an evaluation of the National Council on Radiation Protection and Measurements’ (NCRP) Commentary 27, which concluded that recent epidemiological studies are compatible with the continued use of the LNT model for radiation protection. While this report will likely provide political cover for regulators’ continued reliance on the LNT, it is a missed opportunity to advance the scientific discussion of the effects of low dose, low dose-rate radiation exposure. Due to its Congressionally chartered mission, no organization is better positioned than the NCRP to move this debate forward, and recommendations for doing so in future reviews are provided.

54 ENVIRONMENTAL SCIENCES↗

Symptomatic Pericardial Effusion After Chemoradiation Therapy in Esophageal Cancer Patients

Purpose: We investigated clinical and treatment-related factors as predictors of symptomatic pericardial effusion in esophageal cancer patients after concurrent chemoradiation therapy. Methods and Materials: We reviewed 214 consecutive primary esophageal cancer patients treated with concurrent chemoradiation therapy between 2001 and 2010 in our institute. Pericardial effusion was detected on follow-up computed tomography. Symptomatic effusion was defined as effusion ≥grade 3 according to Common Terminology Criteria for Adverse Events v4.0 criteria. Percent volume irradiated with 5 to 65 Gy (V5-V65) and mean dose to the pericardium were evaluated employing dose-volume histograms. To evaluate dosimetry for patients treated with two-dimensional planning in the earlier period (2001-2005), computed tomography data at diagnosis were transferred to a treatment planning system to reconstruct three-dimensional plans without modification. Optimal dosimetric thresholds for symptomatic pericardial effusion were calculated by receiver operating characteristic curves. Associating clinical and treatment-related risk factors for symptomatic pericardial effusion were detected by univariate and multivariate analyses. Results: The median follow-up was 29 (range, 6-121) months for eligible 167 patients. Symptomatic pericardial effusion was observed in 14 (8.4%) patients. Dosimetric analyses revealed average values of V30 to V45 for the pericardium and mean pericardial doses were significantly higher in patients with symptomatic pericardial effusion than in those with asymptomatic pericardial effusion (P<.05). Pericardial V5 to V55 and mean pericardial doses were significantly higher in patients with symptomatic pericardial effusion than in those without pericardial effusion (P<.001). Mean pericardial doses of 36.5 Gy and V45 of 58% were selected as optimal cutoff values for predicting symptomatic pericardial effusion. Multivariate analysis identified mean pericardial dose as the strongest risk factor for symptomatic pericardial effusion. Conclusions: Dose-volume thresholds for the pericardium facilitate predicting symptomatic pericardial effusion. Mean pericardial dose was selected based not only on the optimal dose-volume threshold but also on the most significant risk factor for symptomatic pericardial effusion.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Real-time signal detection for Cyclotron Radiation Emission Spectroscopy measurements using antenna arrays

Cyclotron Radiation Emission Spectroscopy (CRES) is a technique for precision measurement of the energies of charged particles, which is being developed by the Project 8 Collaboration to measure the neutrino mass using tritium beta-decay spectroscopy. Project 8 seeks to use the CRES technique to measure the neutrino mass with a sensitivity of 40 meV, requiring a large supply of tritium atoms stored in a multi-cubic meter detector volume. Antenna arrays are one potential technology compatible with an experiment of this scale, but the capability of an antenna-based CRES experiment to measure the neutrino mass depends on the efficiency of the signal detection algorithms. Here, in this paper, we develop efficiency models for three signal detection algorithms and compare them using simulations from a prototype antenna-based CRES experiment as a case-study. The algorithms include a power threshold, a matched filter template bank, and a neural network based machine learning approach, which are analyzed in terms of their average detection efficiency and relative computational cost. It is found that significant improvements in detection efficiency and, therefore, neutrino mass sensitivity are achievable, with only a moderate increase in computation cost, by utilizing either the matched filter or machine learning approach in place of a power threshold, which is the baseline signal detection algorithm used in previous CRES experiments by Project 8.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗