Search NASA⌕ Search

SEARCH · Search NASA

Results for “tracking errors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

Direct Measurement of the Nickel Spectrum in Cosmic Rays in the Energy Range from 8.8 GeV/$\mathcal{n}$ to 240 GeV/$\mathcal{n}$ with CALET on the International Space Station

The relative abundance of cosmic ray nickel nuclei with respect to iron is by far larger than for all other transiron elements; therefore it provides a favorable opportunity for a low background measurement of its spectrum. Since nickel, as well as iron, is one of the most stable nuclei, the nickel energy spectrum and its relative abundance with respect to iron provide important information to estimate the abundances at the cosmic ray source and to model the Galactic propagation of heavy nuclei. However, only a few direct measurements of cosmic-ray nickel at energy larger than ~ 3 GeV/n are available at present in the literature, and they are affected by strong limitations in both energy reach and statistics. In this Letter, we present a measurement of the differential energy spectrum of nickel in the energy range from 8.8 to 240 GeV/n , carried out with unprecedented precision by the Calorimetric Electron Telescope (CALET) in operation on the International Space Station since 2015. The CALET instrument can identify individual nuclear species via a measurement of their electric charge with a dynamic range extending far beyond iron (up to atomic number Z = 40 ). The particle’s energy is measured by a homogeneous calorimeter (1.2 proton interaction lengths, 27 radiation lengths) preceded by a thin imaging section (3 radiation lengths) providing tracking and energy sampling. This Letter follows our previous measurement of the iron spectrum [O. Adriani et al. (CALET Collaboration), Phys. Rev. Lett. 126, 241101 (2021).], and it extends our investigation on the energy dependence of the spectral index of heavy elements. It reports the analysis of nickel data collected from November 2015 to May 2021 and a detailed assessment of the systematic uncertainties. In the region from 20 to 240 GeV/n our present data are compatible within the errors with a single power law with spectral index -2.51 ± 0.07 .

79 ASTRONOMY AND ASTROPHYSICS↗

TU-F-17A-05: Calculating Tumor Trajectory and Dose-Of-The-Day for Highly Mobile Tumors Using Cone-Beam CT Projections

Purpose: Cone-beam CT (CBCT) projection images provide anatomical data in real-time over several respiratory cycles, forming a comprehensive picture of tumor movement. We developed a method using these projections to determine the trajectory and dose of highly mobile tumors during each fraction of treatment. Methods: CBCT images of a respiration phantom were acquired, where the trajectory mimicked a lung tumor with high amplitude (2.4 cm) and hysteresis. A template-matching algorithm was used to identify the location of a steel BB in each projection. A Gaussian probability density function for tumor position was calculated which best fit the observed trajectory of the BB in the imager geometry. Two methods to improve the accuracy of tumor track reconstruction were investigated: first, using respiratory phase information to refine the trajectory estimation, and second, using the Monte Carlo method to sample the estimated Gaussian tumor position distribution. 15 clinically-drawn abdominal/lung CTV volumes were used to evaluate the accuracy of the proposed methods by comparing the known and calculated BB trajectories. Results: With all methods, the mean position of the BB was determined with accuracy better than 0.1 mm, and root-mean-square (RMS) trajectory errors were lower than 5% of marker amplitude. Use of respiratory phase information decreased RMS errors by 30%, and decreased the fraction of large errors (>3 mm) by half. Mean dose to the clinical volumes was calculated with an average error of 0.1% and average absolute error of 0.3%. Dosimetric parameters D90/D95 were determined within 0.5% of maximum dose. Monte-Carlo sampling increased RMS trajectory and dosimetric errors slightly, but prevented over-estimation of dose in trajectories with high noise. Conclusions: Tumor trajectory and dose-of-the-day were accurately calculated using CBCT projections. This technique provides a widely-available method to evaluate highly-mobile tumors, and could facilitate better strategies to mitigate or compensate for motion during SBRT.

60 APPLIED LIFE SCIENCES↗

Hanford SMART System: Calculation of Radionuclide Emissions, Ambient Air Concentrations and Error Propagation (Final Report)

This document, authored by Radiological Assessment Corporation (RAC), details the calculations used to convert laboratory radiological analytical sample data and field measurement data for both ambient air samplers and stack air samples to concentration values with associated uncertainty. The RAC supported an effort by Mission Support Alliance (MSA) to replace the Automated Bar Coding of All Samples at Hanford (ABCASH) and Environmental Release Summary (ERS) database software with a commercial off-the-shelf (COTS) data management software system. The ABCASH and ERS databases were not compatible with the Hanford system standards Windows 10 Operating System deployed in calendar year 2018. The replacement software, Sample Management and Analytical Results Tracking (SMART), is used for environmental data collection, analyses, and regulatory reporting for the Hanford Environmental Surveillance and Effluent Monitoring programs.

54 ENVIRONMENTAL SCIENCES↗

BrachyView, a novel in-body imaging system for HDR prostate brachytherapy: Experimental evaluation

Purpose: This paper presents initial experimental results from a prototype of high dose rate (HDR) BrachyView, a novel in-body source tracking system for HDR brachytherapy based on a multipinhole tungsten collimator and a high resolution pixellated silicon detector array. The probe and its associated position estimation algorithms are validated and a comprehensive evaluation of the accuracy of its position estimation capabilities is presented. Methods: The HDR brachytherapy source is moved through a sequence of positions in a prostate phantom, for various displacements in x, y, and z. For each position, multiple image acquisitions are performed, and source positions are reconstructed. Error estimates in each dimension are calculated at each source position and combined to calculate overall positioning errors. Gafchromic film is used to validate the accuracy of source placement within the phantom. Results: More than 90% of evaluated source positions were estimated with an error of less than one millimeter, with the worst-case error being 1.3 mm. Experimental results were in close agreement with previously published Monte Carlo simulation results. Conclusions: The prototype of HDR BrachyView demonstrates a satisfactory level of accuracy in its source position estimation, and additional improvements are achievable with further refinement of HDR BrachyView’s image processing algorithms.

60 APPLIED LIFE SCIENCES↗

Fast Dynamic Aperture Optimization with Reversal Integration

A fast method for dynamic aperture (DA) optimization of storage rings has been developed through the use of reversal integration. Even if dynamical systems have an exact reversal symme- try, a numerical forward integration di ers from its reversal. For chaotic trajectories, cumulative round-o errors are scaled, which results in an exponential growth in the di erence. The exponential e ect, intrinsically associated with the Lyapunov exponent, is a generic indicator of chaos because it represents the sensitivity of chaotic motion to an initial condition. A chaos indicator of the charged particle motion is then obtained by comparing the forward integrations of particle trajectories with corresponding reversals, a.k.a. \backward integrations." The indicator was con rmed to be ob- servable through short-term particle tracking simulations. Therefore, adopting it as an objective function could speed up optimization. The DA of the National Synchrotron Light Source II storage ring, and another test di raction-limited light source ring, were optimized using this method for the purpose of demonstration.

36 MATERIALS SCIENCE↗

Explainable machine learning reveals that local structural motifs encode the thermodynamic state across the CuZr metallic glass-forming range

Metallic glasses derive their properties from the statistics of local atomic motifs rather than from long-range order, yet a quantitative, chemistry-specific link between motif populations and the underlying glassy state has remained elusive. In this work we combine large-scale molecular dynamics, Voronoi tessellation, deep neural networks, and SHapley Additive exPlanations (SHAP) to identify which local structural motifs define the glassy state of Cu—Zr metallic glasses. A dataset of 17,180 atomistic configurations spanning ten compositions (Cu 20 Zr 80 –Cu 80 Zr 20 ) and four quench rates (10 9 –10 12 K/s) is used to train a feed-forward neural network that regresses temperature across the 50–2000 K liquid–supercooled–glass range, achieving a mean absolute error of 19.89 K and R 2 = 0.9974, confirming that the local structural state is faithfully encoded in motif-level structure. SHAP analysis then reveals that a tightly coupled near-icosahedral family of motifs (coordination numbers (CN) 11–13, including the full icosahedron 001200 and its single-atom-perturbation sibling 10930) collectively encodes the thermodynamic state of the system across the full glass-forming range. The CN = 11–13 ordered members carry negative SHAP values at high populations, tracking the most deeply-quenched configurations, while 10930 shows the reversed signature consistent with its role as a soft-spot host whose population shrinks as the icosahedral network deepens. The analysis demonstrates that explainable machine learning can isolate the minimal motif vocabulary defining the glassy state and recovers the near-icosahedral building blocks previously identified by data-driven analyses of Cu—Zr. The approach provides a general, chemistry-specific route for characterizing the structural state of disordered materials.

36 MATERIALS SCIENCE↗

MO-G-18C-03: Evaluation of Deformable Image Registration for Lung Motion Estimation Using Hyperpolarized Gas Tagging MRI

Purpose: Hyperpolarized gas (HP) tagging MRI is a novel imaging technique for direct measurement of lung motion during breathing. This study aims to quantitatively evaluate the accuracy of deformable image registration (DIR) in lung motion estimation using HP tagging MRI as references. Methods: Three healthy subjects were imaged using the HP MR tagging, as well as a high-resolution 3D proton MR sequence (TrueFISP) at the end-of-inhalation (EOI) and the end-of-exhalation (EOE). Ground truth of lung motion and corresponding displacement vector field (tDVF) was derived from HP tagging MRI by manually tracking the displacement of tagging grids between EOI and EOE. Seven different DIR methods were applied to the high-resolution TrueFISP MR images (EOI and EOE) to generate the DIR-based DVFs (dDVF). The DIR methods include Velocity (VEL), MIM, Mirada, multi-grid B-spline from Elastix (MGB) and 3 other algorithms from DIRART toolbox (Double Force Demons (DFD), Improved Lucas-Kanade (ILK), and Iterative Optical Flow (IOF)). All registrations were performed by independent experts. Target registration error (TRE) was calculated as tDVF – dDVF. Analysis was performed for the entire lungs, and separately for the upper and lower lungs. Results: Significant differences between tDVF and dDVF were observed. Besides the DFD and IOF algorithms, all other dDVFs showed similarity in deformation magnitude distribution but away from the ground truth. The average TRE for entire lung ranged 2.5−23.7mm (mean=8.8mm), depending on the DIR method and subject's breathing amplitude. Larger TRE (13.3–23.7mm) was found in subject with larger breathing amplitude of 45.6mm. TRE was greater in lower lung (2.5−33.9 mm, mean=12.4mm) than that in upper lung (2.5−11.9 mm, mean=5.8mm). Conclusion: Significant differences were observed in lung motion estimation between the HP gas tagging MRI method and the DIR methods, especially when lung motion is large. Large variation among different DIR methods was also observed.

60 APPLIED LIFE SCIENCES↗

Technical Note: Evaluation of the systematic accuracy of a frameless, multiple image modality guided, linear accelerator based stereotactic radiosurgery system

Purpose: To evaluate the total systematic accuracy of a frameless, image guided stereotactic radiosurgery system. Methods: The localization accuracy and intermodality difference was determined by delivering radiation to an end-to-end prototype phantom, in which the targets were localized using optical surface monitoring system (OSMS), electromagnetic beacon-based tracking (Calypso®), cone-beam CT, “snap-shot” planar x-ray imaging, and a robotic couch. Six IMRT plans with jaw tracking and a flattening filter free beam were used to study the dosimetric accuracy for intracranial and spinal stereotactic radiosurgery treatment. Results: End-to-end localization accuracy of the system evaluated with the end-to-end phantom was 0.5 ± 0.2 mm with a maximum deviation of 0.9 mm over 90 measurements (including jaw, MLC, and cone measurements for both auto and manual fusion) for single isocenter, single target treatment, 0.6 ± 0.4 mm for multitarget treatment with shared isocenter. Residual setup errors were within 0.1 mm for OSMS, and 0.3 mm for Calypso. Dosimetric evaluation based on absolute film dosimetry showed greater than 90% pass rate for all cases using a gamma criteria of 3%/1 mm. Conclusions: The authors’ experience demonstrates that the localization accuracy of the frameless image-guided system is comparable to robotic or invasive frame based radiosurgery systems.

60 APPLIED LIFE SCIENCES↗

Avian Activity Classification Using Recurrent Networks to Fuse Videos with Metadata on Imbalanced Datasets

Activity classification plays a crucial role in various real-life scenarios involving both humans and animals. There is an increasing need for precise activity classification focused on avian-solar interactions, as the usage of solar energy facilities, such as photovoltaic array power stations, has been observed to impact bird species richness, behavior, and activity. However, there has been no work to develop an automated system to monitor and classify these avian-solar interactions. All current methods rely on human observers, which is time and human resources costly and subject to errors related to searcher efficiency. With the recent success of Deep Learning models in activity classification problems, this paper develops a recurrent neural network-based model to automatically classify six avian activities around solar energy facilities. Our proposed model integrates critical feature engineering metadata with video frame data, enabling improved learning and more accurate activity classification. Furthermore, we address the challenge of data imbalance during training and demonstrate the efficacy of our model in detecting and classifying different activities within video tracks. Additionally, we analyze the saliency/backpropagation map of the trained proposed model and validate its decision-making rationale.

Avian activity classification; bidirectional LSTM;↗

Image quality in thoracic 4D cone-beam CT: A sensitivity analysis of respiratory signal, binning method, reconstruction algorithm, and projection angular spacing

Purpose: Respiratory signal, binning method, and reconstruction algorithm are three major controllable factors affecting image quality in thoracic 4D cone-beam CT (4D-CBCT), which is widely used in image guided radiotherapy (IGRT). Previous studies have investigated each of these factors individually, but no integrated sensitivity analysis has been performed. In addition, projection angular spacing is also a key factor in reconstruction, but how it affects image quality is not obvious. An investigation of the impacts of these four factors on image quality can help determine the most effective strategy in improving 4D-CBCT for IGRT. Methods: Fourteen 4D-CBCT patient projection datasets with various respiratory motion features were reconstructed with the following controllable factors: (i) respiratory signal (real-time position management, projection image intensity analysis, or fiducial marker tracking), (ii) binning method (phase, displacement, or equal-projection-density displacement binning), and (iii) reconstruction algorithm [Feldkamp–Davis–Kress (FDK), McKinnon–Bates (MKB), or adaptive-steepest-descent projection-onto-convex-sets (ASD-POCS)]. The image quality was quantified using signal-to-noise ratio (SNR), contrast-to-noise ratio, and edge-response width in order to assess noise/streaking and blur. The SNR values were also analyzed with respect to the maximum, mean, and root-mean-squared-error (RMSE) projection angular spacing to investigate how projection angular spacing affects image quality. Results: The choice of respiratory signals was found to have no significant impact on image quality. Displacement-based binning was found to be less prone to motion artifacts compared to phase binning in more than half of the cases, but was shown to suffer from large interbin image quality variation and large projection angular gaps. Both MKB and ASD-POCS resulted in noticeably improved image quality almost 100% of the time relative to FDK. In addition, SNR values were found to increase with decreasing RMSE values of projection angular gaps with strong correlations (r ≈ −0.7) regardless of the reconstruction algorithm used. Conclusions: Based on the authors’ results, displacement-based binning methods, better reconstruction algorithms, and the acquisition of even projection angular views are the most important factors to consider for improving thoracic 4D-CBCT image quality. In view of the practical issues with displacement-based binning and the fact that projection angular spacing is not currently directly controllable, development of better reconstruction algorithms represents the most effective strategy for improving image quality in thoracic 4D-CBCT for IGRT applications at the current stage.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Use of Uncertainty in Modeling DFLAW Treatment at Hanford - 17115

Average or mean is understood by most; standard deviation (SD) is understood by few. Certainty is easy to model; uncertainty is not. The flowsheet simulation, described in this paper, placed uncertainties in the G2 model of the Hanford Tank Waste Treatment and Immobilization Plant's (WTP) Direct Feed Low-Activity Waste (DFLAW) process for performance and sensitivity evaluations. G2 is a dynamic material balance model that starts and proceeds with operating logic until all the feed is processed. Dynamic material balance is achieved by tracking the flows, storage, and change of all materials within the plant as time increments. Processing equipment and limitations of the flowsheet are modeled (e.g., equipment types, piping, volumes, flowrates, efficiencies, and physical and chemical environments that impact separations, phase equilibriums, and chemical reactions). Operating logic represents the rules and strategies of a running plant. The G2 model simulated both certainty and uncertainty scenarios for comparison purposes. For the uncertainty scenarios, process decisions were made using presumed values to simulate various operational measurement errors and process variabilities. Presumed means that the known G2 values are adjusted to replicate measurement errors and variabilities. These include: 1) volume measurement, 2) sample analysis, 3) melter decontamination factor (DF), 4) glass former weighing, and 5) glass former composition variations. The errors were randomly generated in accordance with SD values of measurement devices, laboratory methods, and glass former composition ranges. The G2 model runs give insight on the DFLAW process' controllability and the expected range of glass properties. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Optimizing radar scan strategies for tracking isolated deep convection using observing system simulation experiments

Abstract. Optimizing radar observation strategies is one of the most important considerations in pre-field campaign periods. This is especially true for isolated convective clouds that typically evolve faster than the observations captured by operational radar networks. This study investigates uncertainties in radar observations of the evolution of the microphysical and dynamical properties of isolated deep convective clouds developing in clean and polluted environments. It aims to optimize the radar observation strategy for deep convection through the use of high-spatiotemporal cloud-resolving model simulations, which resolve the evolution of individual convective cells every 1 min, coupled with a radar simulator and a cell tracking algorithm. The radar simulation settings are based on the Tracking Aerosol Convection Interactions ExpeRiment (TRACER) and Experiment of Sea Breeze Convection, Aerosols, Precipitation and Environment (ESCAPE) field campaigns held in the Houston, TX, area but are generalizable to other field campaigns focusing on isolated deep convection. Our analysis produces the following four outcomes. First, a 5–7 m s−1 median difference in maximum updrafts of tracked cells is shown between the clean and polluted simulations in the early stages of the cloud lifetimes. This demonstrates the importance of obtaining accurate estimates of vertical velocity from observations if aerosol impacts are to be properly resolved. Second, tracking of individual cells and using vertical cross section scanning every minute capture the evolution of precipitation particle number concentration and size represented by polarimetric observables better than the operational radar observations that update the volume scan every 5 min. This approach also improves multi-Doppler radar updraft retrievals above 5 km above ground level for regions with updraft velocities greater than 10 m s−1. Third, we propose an optimized strategy composed of cell tracking by quick (1–2 min) vertical cross section scans from more than one radar in addition to the operational volume scans. We also propose the use of a single-RHI (range height indicator) updraft retrieval technique for cells close to the radars, for which multi-Doppler radar retrievals are still challenging. Finally, increasing the number of deep convective cells sampled by such observations better represents the median maximum updraft evolution with sample sizes of more than 10 deep cells, which decreases the error associated with sampling the true population to less than 3 m s−1.

54 ENVIRONMENTAL SCIENCES↗

Understanding Biases in Simulated Cloud Radiative Effects in E3SMv3

This study systematically investigates biases in cloud radiative effects (CREs) within the recently released Energy Exascale Earth System Model version 3 (E3SMv3). Compared to its previous version (E3SMv2), E3SMv3 shows excessively strong shortwave CRE over tropical and subtropical oceans, the Southern Ocean, and the Northern Hemisphere storm tracks, which is primarily caused by an overestimation of optically intermediate low clouds. The model also displays excessive longwave CRE over the Maritime Continent and other tropical deep convection regions, resulting from an overestimation of optically thick high clouds. Implementing the Predicted Particle Properties (P3) scheme for stratiform clouds played the most significant role in these cloud changes. In addition, using a double-moment scheme for convective clouds contributed to the increase in intermediate low clouds and optically thick clouds in tropical deep convection regions. Error metrics for total cloud amount (E TCA ), cloud properties (E ctp-τ ), and cloud properties weighted by their SW and LW radiative impacts (E SW and E LW ) indicate that E3SMv3's ability to reproduce observed cloud radiative effect of low, middle, and high clouds has not been improved compared to E3SMv2. Nevertheless, the performance of E3SMv3 remains well within the spread of CMIP6 models, with E SW and E LW values smaller than those in most CMIP6 models. This study underscores the importance of integrating diverse satellite observations for robust cloud evaluation and using cloud-radiation relationships as consistency check for model errors. It suggests that further model developments focus on improving cloud microphysics and their interactions with radiation.

Environmental sciences↗

Dose reconstruction for real-time patient-specific dose estimation in CT

Purpose: Many recent computed tomography (CT) dose reduction approaches belong to one of three categories: statistical reconstruction algorithms, efficient x-ray detectors, and optimized CT acquisition schemes with precise control over the x-ray distribution. The latter category could greatly benefit from fast and accurate methods for dose estimation, which would enable real-time patient-specific protocol optimization. Methods: The authors present a new method for volumetrically reconstructing absorbed dose on a per-voxel basis, directly from the actual CT images. The authors’ specific implementation combines a distance-driven pencil-beam approach to model the first-order x-ray interactions with a set of Gaussian convolution kernels to model the higher-order x-ray interactions. The authors performed a number of 3D simulation experiments comparing the proposed method to a Monte Carlo based ground truth. Results: The authors’ results indicate that the proposed approach offers a good trade-off between accuracy and computational efficiency. The images show a good qualitative correspondence to Monte Carlo estimates. Preliminary quantitative results show errors below 10%, except in bone regions, where the authors see a bigger model mismatch. The computational complexity is similar to that of a low-resolution filtered-backprojection algorithm. Conclusions: The authors present a method for analytic dose reconstruction in CT, similar to the techniques used in radiation therapy planning with megavoltage energies. Future work will include refinements of the proposed method to improve the accuracy as well as a more extensive validation study. The proposed method is not intended to replace methods that track individual x-ray photons, but the authors expect that it may prove useful in applications where real-time patient-specific dose estimation is required.

60 APPLIED LIFE SCIENCES↗

Adaptive AFM scan speed control for high aspect ratio fast structure tracking

Improved imaging rates in Atomic Force Microscopes (AFM) are of high interest for disciplines such as life sciences and failure analysis of semiconductor wafers, where the sample topology shows high aspect ratios. Also, fast imaging is necessary to cover a large surface under investigation in reasonable times. Since AFMs are composed of mechanical components, they are associated with comparably low resonance frequencies that undermine the effort to increase the acquisition rates. In particular, high and steep structures are difficult to follow, which causes the cantilever to temporarily loose contact to or crash into the sample. Here, we report on a novel approach that does not affect the scanner dynamics, but adapts the lateral scanning speed of the scanner. The controller monitors the control error signal and, only when necessary, decreases the scan speed to allow the z-piezo more time to react to changes in the sample's topography. In this case, the overall imaging rate can be significantly increased, because a general scan speed trade-off decision is not needed and smooth areas are scanned fast. In contrast to methods trying to increase the z-piezo bandwidth, our method is a comparably simple approach that can be easily adapted to standard systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Tracing and Forecasting Metabolic Indices of Cancer Patients Using Patient-Specific Deep Learning Models

We develop a patient-specific dynamical system model from the time series data of the cancer patient’s metabolic panel taken during the period of cancer treatment and recovery. The model consists of a pair of stacked long short-term memory (LSTM) recurrent neural networks and a fully connected neural network in each unit. It is intended to be used by physicians to trace back and look forward at the patient’s metabolic indices, to identify potential adverse events, and to make short-term predictions. When the model is used in making short-term predictions, the relative error in every index is less than 10% in the L ∞ norm and less than 6.3% in the L 1 norm in the validation process. Once a master model is built, the patient-specific model can be calibrated through transfer learning. As an example, we obtain patient-specific models for four more cancer patients through transfer learning, which all exhibit reduced training time and a comparable level of accuracy. This study demonstrates that this modeling approach is reliable and can deliver clinically acceptable physiological models for tracking and forecasting patients’ metabolic indices.

60 APPLIED LIFE SCIENCES↗

A continuous surface reconstruction method on point cloud captured from a 3D surface photogrammetry system

Purpose: To accurately and efficiently reconstruct a continuous surface from noisy point clouds captured by a surface photogrammetry system (VisionRT). Methods: The authors have developed a level-set based surface reconstruction method on point clouds captured by a surface photogrammetry system (VisionRT). The proposed method reconstructs an implicit and continuous representation of the underlying patient surface by optimizing a regularized fitting energy, offering extra robustness to noise and missing measurements. By contrast to explicit/discrete meshing-type schemes, their continuous representation is particularly advantageous for subsequent surface registration and motion tracking by eliminating the need for maintaining explicit point correspondences as in discrete models. The authors solve the proposed method with an efficient narrowband evolving scheme. The authors evaluated the proposed method on both phantom and human subject data with two sets of complementary experiments. In the first set of experiment, the authors generated a series of surfaces each with different black patches placed on one chest phantom. The resulting VisionRT measurements from the patched area had different degree of noise and missing levels, since VisionRT has difficulties in detecting dark surfaces. The authors applied the proposed method to point clouds acquired under these different configurations, and quantitatively evaluated reconstructed surfaces by comparing against a high-quality reference surface with respect to root mean squared error (RMSE). In the second set of experiment, the authors applied their method to 100 clinical point clouds acquired from one human subject. In the absence of ground-truth, the authors qualitatively validated reconstructed surfaces by comparing the local geometry, specifically mean curvature distributions, against that of the surface extracted from a high-quality CT obtained from the same patient. Results: On phantom point clouds, their method achieved submillimeter reconstruction RMSE under different configurations, demonstrating quantitatively the faith of the proposed method in preserving local structural properties of the underlying surface in the presence of noise and missing measurements, and its robustness toward variations of such characteristics. On point clouds from the human subject, the proposed method successfully reconstructed all patient surfaces, filling regions where raw point coordinate readings were missing. Within two comparable regions of interest in the chest area, similar mean curvature distributions were acquired from both their reconstructed surface and CT surface, with mean and standard deviation of (μ{sub recon} = − 2.7 × 10{sup −3} mm{sup −1}, σ{sub recon} = 7.0 × 10{sup −3} mm{sup −1}) and (μ{sub CT} = − 2.5 × 10{sup −3} mm{sup −1}, σ{sub CT} = 5.3 × 10{sup −3} mm{sup −1}), respectively. The agreement of local geometry properties between the reconstructed surfaces and the CT surface demonstrated the ability of the proposed method in faithfully representing the underlying patient surface. Conclusions: The authors have integrated and developed an accurate level-set based continuous surface reconstruction method on point clouds acquired by a 3D surface photogrammetry system. The proposed method has generated a continuous representation of the underlying phantom and patient surfaces with good robustness against noise and missing measurements. It serves as an important first step for further development of motion tracking methods during radiotherapy.

60 APPLIED LIFE SCIENCES↗

Digital Quantum Simulation of the Schwinger Model and Symmetry Protection with Trapped Ions

Tracking the dynamics of physical systems in real time is a prime application of quantum computers. Using a trapped-ion system with up to six qubits, we simulate the real-time dynamics of a lattice gauge theory in 1+1 dimensions, i.e., the lattice Schwinger model, and demonstrate nonperturbative effects such as pair creation for times much longer than previously accessible. We study the gate requirement of two formulations of the model using the Suzuki-Trotter product formula, as well as the trade-off between errors from the ordering of the Hamiltonian terms, the Trotter step size, and experimental imperfections. To mitigate experimental errors, a recent symmetry-protection protocol for suppressing coherent errors and a symmetry-inspired postselection scheme are applied. This work demonstrates the integrated theoretical, algorithmic, and experimental approach that is essential for efficient simulation of lattice gauge theories and other complex physical systems.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗