Search NASA⌕ Search

SEARCH · Search NASA

Results for “variable flow”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

Analysis of Hydrology and Interim Measure Performance in the Chromium Plume at Los Alamos National Laboratory - 20498

Hexavalent chromium, Cr(VI), is present in the regional aquifer beneath Los Alamos National Laboratory (LANL) at concentrations greater than the New Mexico groundwater standard (50 ppb). The source of the Cr is blowdown from a power plant where potassium dichromate was used as a corrosion inhibitor from 1956 to 1972. Blowdown comingled with effluent from another source and migrated approximately 3 miles down a canyon, primarily as surface flow, until reaching an alluvial infiltration zone. The infiltrating water moved vertically through a thick (approximately 900 ft), complex stratigraphic sequence of unsaturated tuffs, basalt, and unconsolidated alluvial deposits. Horizontal transport also took place within spatially limited perched groundwater horizons in the vadose zone (VZ). Breakthrough at the regional aquifer water table is thought to have occurred in multiple hydraulic windows or 'drip points' located approximately 3 miles from the initial release site at the power plant. The regional aquifer is highly heterogeneous and anisotropic, and displays unconfined behavior in an upper zone and confined behavior at depth. The Cr(VI) contamination has so far remained confined to the upper approximately 25 m of the aquifer. The ambient hydraulic gradient in the regional aquifer is toward the east/southeast, but the water table is extremely flat in the Cr plume area compared to surrounding areas. There is some local variability in flow direction, potentially related to effects of seasonal pumping from nearby Los Alamos county water-supply wells, which draw from the regional aquifer several hundred feet below the water table. An interim measure (IM) is currently operating at the site to achieve hydraulic control of plume migration using a series of extraction wells, ion-exchange treatment, and injection along the downgradient portion of the plume. The migration of Cr contamination in the aquifer has been previously evaluated using a calibrated probabilistic numerical model, which has also been used to design the spatial configuration of extraction and injection wells for the IM, and to identify locations for monitoring wells. The model is built using the Finite Element Heat and Mass (FEHM) transfer code, and the Model Analysis and Decision Support (MADS) software is used for analyses. To date, the portion of the IM system that has operated in a continuous manner has been very effective at hydraulic control. Modifications to the flow field associated with the influence of IM pumping and injection are evaluated here, with modeling constraints to be provided by recent observations of tracers injected into both monitoring wells and IM injection wells, as well as opportunistic observations of geochemical signatures of treated ion-exchange effluent injected into IM injection wells. The tracer and geochemical data provide insights into modified flow directions within the Cr plume area that cannot be otherwise obtained. Results of the modeling work are being used to inform adaptive management of IM operations and will be a valuable tool for development and refinement of long-term remediation strategies. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Evaluation of a distributed catchment scale water balance model

The validity of some of the simplifying assumptions in a conceptual water balance model is investigated by comparing simulation results from the conceptual model with simulation results from a three-dimensional physically based numerical model and with field observations. We examine, in particular, assumptions and simplifications related to water table dynamics, vertical soil moisture and pressure head distributions, and subsurface flow contributions to stream discharge. The conceptual model relies on a topographic index to predict saturation excess runoff and on Philip's infiltration equation to predict infiltration excess runoff. The numerical model solves the three-dimensional Richards equation describing flow in variably saturated porous media, and handles seepage face boundaries, infiltration excess and saturation excess runoff production, and soil driven and atmosphere driven surface fluxes. The study catchments (a 7.2 sq km catchment and a 0.64 sq km subcatchment) are located in the North Appalachian ridge and valley region of eastern Pennsylvania. Hydrologic data collected during the MACHYDRO 90 field experiment are used to calibrate the models and to evaluate simulation results. It is found that water table dynamics as predicted by the conceptual model are close to the observations in a shallow water well and therefore, that a linear relationship between a topographic index and the local water table depth is found to be a reasonable assumption for catchment scale modeling. However, the hydraulic equilibrium assumption is not valid for the upper 100 cm layer of the unsaturated zone and a conceptual model that incorporates a root zone is suggested. Furthermore, theoretical subsurface flow characteristics from the conceptual model are found to be different from field observations, numerical simulation results, and theoretical baseflow recession characteristics based on Boussinesq's groundwater equation.

Troch, Peter A.↗

Numerical study of groundwater flow cycling controlled by seawater/freshwater interaction in Woodville Karst Plain

Seawater intrusion due to sea level rise and climate change could significantly contaminate coastal groundwater resources, particularly in Florida, the flat low-land state in the United States. Based on the field investigation and hydrological measurements, a three-dimensional SEAWAT model is developed to evaluate the groundwater flow cycling and seawater intrusion to freshwater system in the Woodville Karst Plain (WKP), a typical karst groundwater system in the Floridan aquifer. The karst conduit network in the aquifer acts as fast flow pathway for groundwater flow and solute transport, so seawater could deeply intrude into the aquifer. Wakulla Spring, an inland spring 17 km from the coast and a coastal submarine spring, Spring Creek Spring Complex are connected through the conduit network. The flow direction between the two springs switches under various rainfall conditions in this region, thus the discharges at two karst springs are used to estimate the location of seawater/freshwater mixing interface. The SEAWAT modeling results indicate that the mixing interface, defined as 2 PSU (Practical Salinity Unit), intrudes 3 to 5 km through the subsurface karst conduit during the dry season and severely contaminates nearly 1 km width of groundwater around the conduit. The salinity distribution and the distance of seawater intrusion through the conduit system are very sensitive to precipitation variation and the sea level boundary condition. Furthermore, predictions are made for seawater intrusion to the aquifer under various sea level rise, precipitation scenarios and water pumping. The results show that the seawater intrusion could reach and contaminate inland freshwater systems if sea level rises 1.0 m or during a long-term no-precipitation season. Finally, this study provides insights for modeling and predicting the vulnerability of a coastal karst aquifer through the simulation of variable-density flow.

58 GEOSCIENCES↗

Numerical study of variable density turbulence interaction with a normal shock wave

Accurate numerical simulations of shock–turbulence interaction (STI) are conducted with a hybrid monotonicity-preserving–compact-finite-difference scheme for a detailed study of STI in variable density flows. Theoretical and numerical assessments of data confirm that all turbulence scales as well as the STI are well captured by the computational method. Linear interaction approximation (LIA) convergence tests conducted with the shock-capturing simulations exhibit a similar trend of converging to LIA predictions to shock-resolving direct numerical simulations (DNS). The effects of density variations on STI are studied by comparing the results corresponding to an upstream multi-fluid mixture with the single-fluid case. Here the results show that for the current parameter ranges, the turbulence amplification by the normal shock wave is much higher and the reduction in turbulence length scales is more significant when strong density variations exist. Turbulent mixing enhancement by the shock is also increased and stronger mixing asymmetry in the postshock region is observed when there is significant density variation. The turbulence structure is strongly modified by the shock wave, with a differential distribution of turbulent statistics in regions having different densities. The dominant mechanisms behind the variable density STI are identified by analysing the transport equations for the Reynolds stresses, vorticity, normalized mass flux and density specific volume covariance.

42 ENGINEERING↗

Method development for determining the hydraulic conductivity of fractured porous media

Plausible, but unvalidated, theoretical model constructs for unsaturated hydraulic conductivity of fractured porous media are currently used in Performance Assessment (PA) modeling for cracked saltstone and concrete (Flach 2011). The Nuclear Regulatory Commission (NRC) has expressed concern about the lack of model support for these assumed Moisture Characteristic Curves (MCC) data, as noted in Requests for Additional Information (RAIs) PA-8 and SP-4 (Savannah River Remediation, LLC, 2011). The objective of this task was to advance PA model support by developing an experimental method for determining the hydraulic conductivity of fractured cementitious materials under unsaturated conditions, and to demonstrate the technique on fractured saltstone samples. The task was requested through Task Technical Request (TTR) HLW-SSF-TTR-2012-0016 and conducted in accordance with Task Technical & Quality Assurance Plan (TTQAP) SRNL-TR-2012-00090. Preliminary method development previously conducted by Kohn et al. (2012) identified transient outflow extraction as the most promising method for characterizing the unsaturated properties of fractured porous media. While the research conducted by Kohn et al. (2012) focused on fractured media analogs such as stacked glass slides, the current task focused directly on fractured saltstone. For this task, four sample types with differing fracture geometries were considered: 1) intact saltstone, 2) intact saltstone with a single saw cut, smooth surface fracture, 3) micro-fractured saltstone (induced by oven drying), and 4) micro-fractured saltstone with a single, fully-penetrating, rough-surface fracture. Each sample type was tested initially for saturated hydraulic conductivity following method ASTM D 5084 using a flexible wall permeameter. Samples were subsequently tested using the transient outflow extraction method to determine cumulative outflow as a function of time and applied pressure. Of the four sample types tested, two yielded datasets suitable for analysis (sample types 3 and 4). The intact saltstone sample (sample type 1) did not yield any measureable outflow over the pressure range of the outflow test (0-1000 cm H 2 O). This was expected because the estimated air entry pressure for intact saltstone is on the order of 100,000 cm H 2 O (Dixon et al., 2009). The intact saltstone sample with a single saw cut smooth surface fracture (sample type 2) did not produce useable data because the fracture completely drained at less than 10 cm H 2 O applied pressure. The cumulative outflow data from sample types 3 and 4 were analyzed using an inverse solution of the Richard’s equation for water flow in variably saturated porous media. This technique was implemented using the computer code Hydrus-1D (Šimunek et al., 2008) and the resulting output included the van Genuchten-Mualem water retention and relative permeability parameters and predicted saturated hydraulic conductivity (Van Genuchten, 1980; Van Genuchten et al., 1991). Estimations of relative permeability and saturated conductivity are possible because the transient response of the sample to pressure changes is recorded during the multi-step outflow extraction test. Characteristic curves were developed for sample types 3 and 4 based on the results of the transient outflow method and compared to that of intact saltstone previously reported by Dixon et al. (2009). The overall results of this study indicate that the outflow extraction method is suitable for measuring the hydraulic properties of micro-fractured porous media. The resulting cumulative outflow data can be analyzed using the computer code Hydrus-1D to generate the van Genuchten curve fitting parameters that adequately describe fracture drainage. The resulting characteristic curves are consistent with blended characteristic curves that combine the behaviors of low pressure drainage associated with fracture flow with high pressure drainage from the bulk saltstone matrix.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Process design tools and techno-economic analysis for capacitive deionization

Capacitive deionization (CDI) devices use cyclical electrosorption on porous electrode surfaces to achieve water desalination. Process modeling and design of CDI systems requires accurate treatment of the coupling among input electrical forcing, input flow rates, and system responses including salt removal dynamics, water recovery, energy storage, and dissipation. Techno-economic analyses of CDI further require a method to calculate and compare between a produced commodity (e.g. desalted water) versus capital and operational costs of the system. In this work, we demonstrate a new modeling and analysis tool for CDI developed as an installable Matlab program that allows direct numerical simulation of CDI dynamics and calculation of key performance and cost parameters. The program is provided for free and is used to run open-source Simulink models. The Simulink environment sends information to the program and allows for a drag and drop design space where users can connect CDI cells to relevant periphery blocks such as grid energy, battery, solar panel, waste disposal, and maintenance/labor cost streams. The program allows for simulation of arbitrary current forcing and arbitrary flow rate forcing of one or more CDI cells. We employ validated well-mixed reactor formulations together with a non-linear circuit model formulation that can accommodate a variety of electric double layer sub-models (e.g. for charge efficiency). The program includes a graphical user interface (GUI) to specify CDI plant parameters, specify operating conditions, run individual tests or parameter batch-mode simulations, and plot relevant results. The techno-economic models convert among dimensional streams of species (e.g. feed, desalted water, and brine), energy, and cost and enable a variety of economic estimates including levelized water costs.

42 ENGINEERING↗

Simulating bioclogging effects on dynamic riverbed permeability and infiltration

Bioclogging in rivers can detrimentally impact aquifer recharge. This is particularly so in dry regions, where losing rivers are common, and where disconnection between surface water and groundwater (leading to the development of an unsaturated zone) can occur. Reduction in riverbed permeability due to biomass growth is a time-variable parameter that is often neglected, yet permeability reduction from bioclogging can introduce order of magnitude changes in seepage fluxes from rivers over short (i.e., monthly) timescales. To address the combined effects of bioclogging and disconnection on infiltration, we developed in this paper numerical representations of bioclogging processes within a one-dimensional, variably saturated flow model representing losing-connected and losing-disconnected rivers. We tested these formulations using a synthetic case study informed with biological data obtained from the Russian River, California, USA. Our findings show that modeled biomass growth reduced seepage for losing-connected and losing-disconnected rivers. However, for rivers undergoing disconnection, infiltration declines occurred only after the system was fully disconnected. Before full disconnection, biologically induced permeability declines were not significant enough to offset the infiltration gains introduced by disconnection. The two effects combine to lead to a characteristic infiltration curve where peak infiltration magnitude and timing is controlled by permeability declines relative to hydraulic gradient gains. Biomass growth was found to hasten the onset of full disconnection; a condition we term ‘effective disconnection’. Finally, our results show that river infiltration can respond dynamically to bioclogging and subsequent permeability declines that are highly dependent on river connection status.

58 GEOSCIENCES↗

Development of an Optimal Variable-Pitch Controller for Floating Axial-Flow Marine Hydrokinetic Turbines

This article discusses the development of an optimal variable-pitch controller for floating, axial-flow marine turbines. Recently, OpenFAST, an open-source wind turbine modeling tool, has been extended to model marine turbines. A controller is necessary to simulate marine turbines for different load cases using OpenFAST, which greatly impacts the performance of the energy system. Previous studies have designed controllers using a linearized model of the marine turbine, which can be time-consuming and require the expertise of a control engineer. In this study, we use an automated approach that uses generic models of the marine turbine to identify the controller gains, which can expedite the process of designing a controller. Using an optimizer to identify the control system parameters can additionally improve the controller's performance. The optimal controller tuned using such an approach results in a 20% reduction in the tower-base damage equivalent loading and better tracking of the rated generator speed and power.

axial flow↗

Verification of Energy Reduction Effect through Control Optimization of Supply Air Temperature in VRF-OAP System

This paper developed an algorithm that controls the supply air temperature in the variable refrigerant flow (VRF), outdoor air processing unit (OAP) system, according to indoor and outdoor temperature and humidity, and verified the effects after applying the algorithm to real buildings. The VRF-OAP system refers to a heating, ventilation, and air conditioning (HVAC) system to complement a ventilation function, which is not provided in the VRF system. It is a system that supplies air indoors by heat treatment of outdoor air through the OAP, as a number of indoor units and OAPs are connected to the outdoor unit in the VRF system simultaneously. This paper conducted experiments with regard to changes in efficiency and the cooling capabilities of each unit and system according to supply air temperature in the OAP using a multicalorimeter. Based on these results, an algorithm that controlled the temperature of the supply air in the OAP was developed considering indoor and outdoor temperatures and humidity. The algorithm was applied in the test building to verify the effects of energy reduction and the effects on indoor temperature and humidity. Loads were then changed by adjusting the number of conditioned rooms to verify the effect of the algorithm according to various load conditions. In the field test results, the energy reduction effect was approximately 15–17% at a 100% load, and 4–20% at a 75% load. However, no significant effects were shown at a 50% load. The indoor temperature and humidity reached a comfortable level.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A priori analysis on deep learning of subgrid-scale parameterizations for Kraichnan turbulence

In the present study, we investigate different data-driven parameterizations for large eddy simulation of two-dimensional turbulence in the a priori settings. These models utilize resolved flow field variables on the coarser grid to estimate the subgrid-scale stresses. We use data-driven closure models based on localized learning that employs a multilayer feedforward artificial neural network with point-to-point mapping and neighboring stencil data mapping, and convolutional neural network fed by data snapshots of the whole domain. The performance of these data-driven closure models is measured through a probability density function and is compared with the dynamic Smagorinksy model (DSM). The quantitative performance is evaluated using the cross-correlation coefficient between the true and predicted stresses. We analyze different frameworks in terms of the amount of training data, selection of input and output features, their characteristics in modeling with accuracy, and training and deployment computational time. We also demonstrate computational gain that can be achieved using the intelligent eddy viscosity model that learns eddy viscosity computed by the DSM instead of subgrid-scale stresses. Here, we detail the hyperparameters optimization of these models using the grid search algorithm.

42 ENGINEERING↗

An efficient three-dimensional rhizosphere modeling capability to study the effect of root system architecture on soil water and reactive transport

This research was to develop a rhizosphere modeling capability for plant-soil interactions by integrating water and ion uptake and release from three dimensional (3D) root systems and 3D variably saturated flow and multicomponent reactive transport in soil. We combined open source software for simulating plant and soil interactions with parallel processing computational technologies to address highly-resolved root system architecture and soil hydrobiogeochemical processes. Simulation capability was demonstrated on Brachypodium distachyon . Our demonstration problem showed that availability of water and plant nutrients is controlled by the interplay between 1) transpiration-driven cycles of water uptake, root zone saturation and desaturation; 2) sorption and desorption via competitive ion exchange; 3) buildup of ions not taken up during kinetic uptake of nutrients/ions from pore water; and 4) advection, dispersion, and diffusion of ions in the soil. The uptake of water and ions by individual roots leads to dynamic, local gradients in ion concentrations. The resulting higher solution ionic strength can lead to increasing sorption of K+ and NH4+ on the soil exchange sites, despite their preferential absorption by roots. The modeling framework makes it possible to explore alternative conceptual models and improve the understanding of the biogeochemical and physical environment within the rhizosphere.

59 BASIC BIOLOGICAL SCIENCES↗

A jet fuel surrogate formulated by real fuel properties

An implicit methodology based on chemical group theory to formulate a jet aviation fuel surrogate by the measurements of several combustion related fuel properties is tested. The empirical formula and derived cetane number of an actual aviation fuel, POSF 4658, have been determined. A three component surrogate fuel for POSF 4658 has been formulated by constraining a mixture of n-decane, iso-octane and toluene to reproduce the hydrogen/carbon ratio and derived cetane number of the target fuel. The validity of the proposed surrogate is evaluated by experimental measurement of select combustion properties of POSF 4658, and the POSF 4658 surrogate. (1)A variable pressure flow reactor has been used to chart the chemical reactivity of stoichiometric mixtures of POSF 4658/O{sub 2}/N{sub 2} and POSF 4658 surrogate/O{sub 2}/N{sub 2} at 12.5 atm and 500-1000 K, fixing the carbon content at 0.3% for both mixtures. (2)The high temperature chemical reactivity and chemical kinetic-molecular diffusion coupling of POSF 4658 and POSF 4658 surrogate have been evaluated by measurement of the strained extinction limit of diffusion flames. (3)The autoignition behavior of POSF 4658 and POSF 4658 surrogate has been measured with a shock tube at 674-1222 K and with a rapid compression machine at 645-714 K for stoichiometric mixtures of fuel in air at pressures close to 20 atm. The flow reactor study shows that the character and extent of chemical reactivity of both fuels at low temperature (500-675 K) and high temperature (900 K+) are extremely similar. Slight differences in the transition from the end of the negative temperature coefficient regime to hot ignition are observed. The diffusion flame strained extinction limits of the fuels are observed to be indistinguishable when compared on a molar basis. Ignition delay measurements also show that POSF 4658 exhibits NTC behavior. Moreover, the ignition delays of both fuels are also extremely similar over the temperature range studied in both shock tube and rapid compression machine experiments. A chemical kinetic model is constructed and utilized to interpret the experimental observations and provides a rationale as to why the real fuel and surrogate fuel exhibit such similar reactivity. (author)

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A DNS evaluation of mixing models for transported PDF modelling of turbulent nonpremixed flames

Transported probability density function (TPDF) approaches are well suited to modelling turbulent, reacting, variable density flows. One of the main challenges to the successful deployment of TPDF methods is accurately modelling the unclosed molecular mixing term. This study examines three of the most widely used mixing models: the Interaction by Exchange with the Mean (IEM), Modified Curl (MC) and Euclidean Minimum Spanning Tree (EMST) models. Direct numerical simulation (DNS) data-sets were used to provide both initial conditions and inputs needed over the course of the runs, including the mean flow velocities, mixing frequency, and the turbulent diffusion coefficient. The same chemical mechanism and thermodynamic properties were used, allowing the study to focus on the mixing model. The simulation scenario was a one-dimensional, nonpremixed, turbulent jet flame burning either a syngas or ethylene fuel stream that featured extinction and reignition. This test scenario was selected because extinction and reignition phenomena are sensitive to the mixing model. Three DNS cases were considered for both the syngas and ethylene cases with a parametric variation of Reynolds and Damköhler numbers, respectively. Extinction events became more popular with increasing Reynolds number in the syngas cases and with decreasing Damköhler number in the ethylene cases. The model was first tested with the mixing frequency defined from the dissipation rate and variance of mixture fraction. With this definition, for the syngas cases this study finds that the TPDF method is successful at predicting flame extinction and reignition using all three mixing models for the relatively lower and intermediate Reynolds number cases, but that all models under-predict reignition in the relatively higher Reynolds number case. In the ethylene fuelled cases, only the EMST mixing model correctly predicts the reignition event for the two higher Damköhler number cases, yet, in the lowest Damköhler number case the EMST model over-predicts reignition and the IEM and MC models under-predict it. Mixing frequency was then modelled based on the turbulence frequency and a model constant $C_{\phi}$, the ratio of scalar to mechanical mixing rates. The DNS cases were reexamined with this definition and the findings suggested that the optimal value for $C_{\phi}$ is mixing model and case dependent. In particular, it was found in the ethylene case considered that reignition could be achieved with the IEM and MC models by adjusting the value of $C_{\phi}$.

42 ENGINEERING↗

A framework for quantifying the impact of occupant behavior on energy savings of energy conservation measures

To improve energy efficiency—during new buildings design or during a building retrofit—evaluating the energy savings potential of energy conservation measures (ECMs) is a critical task. In building retrofits, occupant behavior significantly impacts building energy use and is a leading factor in uncertainty when determining the effectiveness of retrofit ECMs. Current simulation-based assessment methods simplify the representation of occupant behavior by using a standard or representative set of static and homogeneous assumptions ignoring the dynamics, stochastics, and diversity of occupant's energy-related behavior in buildings. The simplification contributes to significant gaps between the simulated and measured actual energy performance of buildings. This paper presents a framework for quantifying the impact of occupant behaviors on ECM energy savings using building performance simulation. During the first step of the study, three occupant behavior styles (austerity, normal, and wasteful) were defined to represent different levels of energy consciousness of occupants regarding their interactions with building energy systems (HVAC, windows, lights and plug-in equipment). Next, a simulation workflow was introduced to determine a range of the ECM energy savings. Then, guidance was provided to interpret the range of ECM savings to support ECM decision making. Finally, a pilot study was performed in a real building to demonstrate the application of the framework. Simulation results show that the impact of occupant behaviors on ECM savings vary with the type of ECM. Occupant behavior minimally affects energy savings for ECMs that are technology-driven (the relative savings differ by less than 2%) and have little interaction with the occupants; for ECMs with strong occupant interaction, such as the use of zonal control variable refrigerant flow system and natural ventilation, energy savings are significantly affected by occupant behavior (the relative savings differ by up to 20%). Finally, the study framework provides a novel, holistic approach to assessing the uncertainty of ECM energy savings related to occupant behavior, enabling stakeholders to understand and assess the risk of adopting energy efficiency technologies for new and existing buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Operation and performance of VRF systems: Mining a large-scale dataset

The energy consumption of air-conditioning systems has gained increasing attention as it contributes significantly to the global building energy use. The variable refrigerant flow (VRF) system is a common air-conditioning system applied widely in residential and office buildings in China. Understanding the actual operation and performance of VRF systems is fundamental for the energy-efficient design and operation of VRF systems. Previous research on VRF system operation used either limited field data covering certain building types and climate zones or used a questionnaire to obtain a larger dataset. However, they did not capture the wide applications of VRF systems quantitatively across all building types, climate zones, and operating conditions. To fill this gap, statistical and clustering analysis was conducted on the newly proposed key performance indicators of approximately 287,000 VRF systems for residential and commercial buildings in all five climate zones in China. In this work, the main findings are: (1) VRF systems are mainly used for cooling in all climate zones in China; (2) among all building types, the duration of use is lowest in residential buildings and highest in hotels and medical buildings; (3) the distribution of the ideal VRF cooling coefficient of performance (COP) is similar across all climate zones and building types; whereas the COPs of ideal VRF heating in the Severe Cold region and Cold regions are lower than those in other climate zones; and (4) partial load operations for VRF systems are common in residential buildings and office buildings due to the part-time-part-space operation mode. These findings can inform the actual application of VRF systems in China, supporting the design, operation, industry standard development, and performance optimization of VRF systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Effects of hydration on fractures and shale permeability under different confining pressures: An experimental study

Water-rich fracturing fluids are injected into gas shale formations to promote the effective development of gas. However, the relationship between gas production decreases and the variability flow-back fluid behavior (rate and amount) remains a significant challenge to the industry. This study focused on the effects of water hydration on the rock fracture properties of a major gas shale formation in China. Shale from hydration experiments was characterized for a number of key parameters including length, volume, width, surface area, thickness and fracture frequency. X-ray computed tomography (CT) scanning was conducted on shale reservoir samples exposed to water at zero overburden stress and under three different confining pressures (725 psi, 2175 psi, and 2900 psi). CT scanning images were obtained to evaluate fracture evolutions during hydration for both the connected and unconnected fracture networks. In addition, permeabilities before and after hydration were also quantified. Results from the ambient condition experiment revealed the propagation of fractures, the formation of new fractures, and the formation of better connectivity caused by a more complicated fracture network. However, the fracture evolution of the other three samples under confining pressures are markedly different, including: more unconnected fracture networks, less fracture volume, and a poorer connectivity of fractures.

bio-inspired, mechanical behavior, carbon sequestr↗

Uncertainty estimation of bifurcated solutions in the Rayleigh–Bénard problem for advanced nuclear reactors applications

Multiphysics models of nuclear reactors frequently comprise nonlinear systems of equations. The nonlinear nature of these models could lead to solution bifurcations, where a small change in a certain parameter, e.g., the thermophysical properties of the coolant, can lead to a sudden change in the system’s behavior. At the point in parameter space where this happens, called a critical point, the Jacobian matrix of the model’s nonlinear operator becomes singular potentially permitting multiple solutions to coexist. In this paper, we perform uncertainty estimation (UE) in a parameter range that includes bifurcated solutions within the context of Rayleigh–Bénard problem. We perform this analysis assuming uncertain temperature difference, and tilt angle for the iterative solution algorithm with a unit Prandtl number (Pr = 1). Also, we perform this analysis under uncertain thermophysical properties for both FLiBe molten salt and liquid sodium as working fluid. We deploy two approaches to compute statistical moments for the resulting distributions of selected flow-field variables. The first approach is the blind computation of the mean and the standard deviation without any consideration of solution bifurcation, while the second approach utilizes k-means clustering to cluster each branch’s solutions together and compute separate statistical moments for each branch. The statistical distributions are obtained by perturbing the selected parameters about nominal values that correspond to a solution on one of the valid branches, and that solution is used as initial guess for the iterative solution algorithm. We found that perturbation of any parameter when its nominal value is close to its critical point always leads to branch jumping, i.e., the iterations converge to a solution on a branch different from the branch of the initial guess. This produces a statistical ensemble comprised of fundamentally different solutions leading to wrong mean values and uncertainty estimates, whereas clustering provides an efficient way to deal with this type of computation. This work is important for developing Gen IV nuclear systems because many of these systems rely on natural convection for cooling especially in accident conditions.

97 - MATHEMATICS AND COMPUTING↗