Search NASA⌕ Search

SEARCH · Search NASA

Results for “vertically aligned”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

A Parameterization of the Cloud Scattering Polarization Signal Derived From GPM Observations for Microwave Fast Radative Transfer Models

Microwave cloud polarized observations have shown the potential to improve precipitation retrievals since they are linked to the orientation and shape of ice habits. Stratiform clouds show larger brightness temperature (TB) polarization differences (PDs), defined as the vertically polarized TB (TBV) minus the horizontally polarized TB (TBH), with ~10 K PD values at 89 GHz due to the presence of horizontally aligned snowflakes, while convective regions show smaller PD signals, as graupel and/or hail in the updraft tend to become randomly oriented. The launch of the global precipitation measurement (GPM) microwave imager (GMI) has extended the availability of microwave polarized observations to higher frequencies (166 GHz) in the tropics and midlatitudes, previously only available up to 89 GHz. This study analyzes one year of GMI observations to explore further the previously reported stable relationship between the PD and the observed TBs at 89 and 166 GHz, respectively. The latitudinal and seasonal variability is analyzed to propose a cloud scattering polarization parameterization of the PD-TB relationship, capable of reconstructing the PD signal from simulated TBs. Given that operational radiative transfer (RT) models do not currently simulate the cloud polarized signals, this is an alternative and simple solution to exploit the large number of cloud polarized observations available. Finally, the atmospheric radiative transfer simulator (ARTS) is coupled with the weather research and forecasting (WRF) model, in order to apply the proposed parameterization to the RT simulated TBs and hence infer the corresponding PD values, which show to reproduce the observed GMI PDs well.

54 ENVIRONMENTAL SCIENCES↗

Horn Location Sensors (HLS) for LBNF

The Long-Baseline Neutrino Facility (LBNF) will deliver the world's most powerful muon neutrino beam to the Deep Underground Neutrino Experiment (DUNE), initially operating at 1.2 MW and upgradeable to 2.4 MW. Ensuring the accurate direction of this beam is critical for DUNE's precision goals. This talk introduces the Horn Location Sensors (HLS) system, designed to provide precise, relative measurements of the focusing horns, targets, and beam position monitors in the neutrino beamline. The HLS system employs high-precision FSI-based hydrostatic leveling sensors to track vertical motion and tilt, achieving precision on the order of 0.1 mm. Built for minimal maintenance in radioactive environments, the HLS system ensures precise alignment of beamline components during high-power operations. This system is essential for maintaining beam accuracy and enhancing DUNE's scientific performance.

43 PARTICLE ACCELERATORS↗

Bottlebrush Block Copolymer Thin Films

The self-assembly of block copolymers (BCPs) in thin films is governed by interfacial interactions (enthalpy) between the blocks and interfaces (at both the substrate and the surface). Advantage can also be taken of entropy to control the polymer orientation. Here, we synthesized a series of bottlebrush block copolymers (BBCPs), with deuterated polystyrene (DPS) as the core block and poly­(solketal acrylate) (PSA) as the corona block, where the backbone length (N BB) and grafting densities (GDs) were varied. The hydrophobic PSA block was converted to a hydrophilic poly­(glyceryl acrylate) (PGA) block by solid-state hydrolysis, bringing the BBCP from a disordered state into an ordered state with a lamellar microdomain morphology. The orientation of the morphology as a function of distance from the interfaces was systematically investigated by atomic force microscopy (AFM), interference microscopy, grazing-incidence small-angle X-ray scattering (GISAXS), and grazing-incidence small angle neutron scattering (GISANS). For N BB = 1 (diblock BCP), a mixed lamellar orientation was found. For N BB = 5 (star-like BBCP), a vertical orientation of the lamellar microdomains was found dominantly at the interfaces that propagated into the bulk of the film due to the entropic penalty associated with constraints on the junction points. Increasing the N BB to 50 (rod-like BBCP) and 100 (worm-like BBCP) yielded a random orientation, as the side chains became overcrowded when aligned in the same direction. By reducing the grafting density (GD) of a N BB = 50 BBCP from 100% to 75% and 50% by the incorporation of spacers into the backbone, the steric hindrance of side chains is reduced markedly, facilitating a vertical orientation of the lamellar microdomains. However, the vertical orientation becomes more random within the bulk of the thin film for different BBCP architectures. By modifying the substrate with a layer of PS, the preferential interactions between the core block of the BBCP and the interfaces induce a reconfiguration of the BBCP, drawing the core block out to contact substrate directly driven by enthalpy. Under these conditions, N BB = 5 showed a predominantly parallel orientation of the lamellar microdomains with the corona block minimizing contact with the substrate. Higher N BB values of 50 and 100 showed a more random orientation of the lamellar microdomains at different depths on the PS-modified substrate. Overall, thin-film morphology was regulated by tuning the configuration of the BBCP, varying the entropic contribution to the microdomain orientation.

Chen, Zhan↗

Coil Creep and Skew-Quadrupole Field Components in the Tevatron

During the start-up of Run II of the Tevatron Collider program, several issues surfaced which were not present, or not seen as detrimental, during Run I. These included the repeated deterioration of the closed orbit requiring orbit smoothing every two weeks or so, the inability to correct the closed orbit to desired positions due to various correctors running at maximum limits, regions of systematically strong vertical dipole corrections, and the identification of very strong coupling between the two transverse degrees-of-freedom. It became apparent that many of the problems being experienced operationally were connected to a deterioration of the main dipole magnet alignment, and remedial actions were undertaken. However, the alignment alone was not enough to explain the corrector strengths required to handle transverse coupling. With one exception, strong coupling had generally not been an issue in the Tevatron during Run I. Based on experience with the Main Ring, the Tevatron was designed with a very strong skew quadrupole circuit to compensate any quadrupole alignment and skew quadrupole field errors that might present themselves. The circuit was composed of 48 correctors placed evenly throughout the arcs, 8 per sector, evenly placed in every other cell. Other smaller circuits were installed but not initially needed or commissioned. These smaller circuits were composed of individual skew quadrupole correctors on either side of the long straight sections. These circuits were tuned by first bringing the horizontal and vertical tunes near each other. The skew quadrupoles were then adjusted to minimize tune split, usually to less than 0.003. Initially, the main skew quad circuit (designated T:SQ) could accomplish this global decoupling with only 4% of its possible current, and the smaller circuits were not required at all. The start-up of Run Ib was complicated by what was later discovered to be a rolled triplet quadrupole magnet in one of the Interaction Regions. This led to a reduction in luminosity of nearly 50%, as well as operational confusion until it was uncovered. By the time Collider Run II began, the current needed on the main SQ circuit had increased to 60% of its maximum value. Some of the smaller circuits were also needed to fully decouple the tunes. With this history, several studies were performed early in Run II to search for strong local coupling sources like the triplet quadrupole, but without success. The strong corrector settings were indicative of a much larger problem than a single rolled magnet, and the locality of the error was hard to deduce from the setting of a global correction system. Several possible reasons for the increase in coupling were investigated.

43 PARTICLE ACCELERATORS↗

HALL EFFECT CONTROLLED GAS DYNAMICS IN PROTOPLANETARY DISKS. II. FULL 3D SIMULATIONS TOWARD THE OUTER DISK

We perform three-dimensional stratified shearing-box magnetohydrodynamic (MHD) simulations on the gas dynamics of protoplanetary disks with a net vertical magnetic flux of B {sub z0}. All three nonideal MHD effects, Ohmic resistivity, the Hall effect, and ambipolar diffusion, are included in a self-consistent manner based on equilibrium chemistry. We focus on regions toward outer disk radii, from 5 to 60 AU, where Ohmic resistivity tends to become negligible, ambipolar diffusion dominates over an extended region across the disk height, and the Hall effect largely controls the dynamics near the disk midplane. We find that at around R = 5 AU the system launches a laminar or weakly turbulent magnetocentrifugal wind when the net vertical field B {sub z0} is not too weak. Moreover, the wind is able to achieve and maintain a configuration with reflection symmetry at the disk midplane. The case with anti-aligned field polarity (Ω⋅B{sub z0}<0) is more susceptible to the magnetorotational instability (MRI) when B {sub z0} decreases, leading to an outflow oscillating in radial directions and very inefficient angular momentum transport. At the outer disk around and beyond R = 30 AU, the system shows vigorous MRI turbulence in the surface layer due to far-UV ionization, which efficiently drives disk accretion. The Hall effect affects the stability of the midplane region to the MRI, leading to strong/weak Maxwell stress for aligned/anti-aligned field polarities. Nevertheless, the midplane region is only very weakly turbulent in both cases. Overall, the basic picture is analogous to the conventional layered accretion scenario applied to the outer disk. In addition, we find that the vertical magnetic flux is strongly concentrated into thin, azimuthally extended shells in most of our simulations beyond 15 AU, leading to enhanced radial density variations know as zonal flows. Theoretical implications and observational consequences are briefly discussed.

79 ASTRONOMY AND ASTROPHYSICS↗

Early Clinical Experience With Kilovoltage Image-Guided Radiation Therapy for Interfraction Motion Management

Interest in image-guided radiation therapy (IGRT) reflects the desire to minimize interfraction positioning variability. Using a kilovoltage (kV) imaging unit mounted to a traditional LINAC allows daily matching of kV images to planning digitally reconstructed radiographs (DRRs). We quantify and evaluate the significance of calculated deviation from the intended isocenter. Since September 2004, 117 patients with various malignancies were treated using the On-Board Imaging (OBI) system, with 2088 treatment sessions. Patients were positioned by the treating therapist; orthogonal images were then obtained with the OBI unit. Couch shifts were made, aligning bony anatomy to the initial simulation image. Routine port films were performed weekly (after that day's OBI session). Ninety percent of all lateral, longitudinal, and vertical shifts were less than 0.8 cm, 0.6 cm, and 0.7 cm, respectively. The median vector shift for each anatomic site was: 0.42 cm for head and neck, 0.40 cm for CNS, 0.59 cm for GU/prostate, and 0.73 cm for breast; shift magnitude did not change with successive OBI sessions. The use of OBI effectively corrects setup variability. These shifts are typically small and random. The use of OBI likely can replace weekly port films for isocenter verification; however, OBI does not provide field shape verification.

61 RADIATION PROTECTION AND DOSIMETRY↗

THE IMPACT OF BARYON PHYSICS ON THE STRUCTURE OF HIGH-REDSHIFT GALAXIES

We study the detailed structure of galaxies at redshifts z {>=} 2 using cosmological simulations with improved modeling of the interstellar medium and star formation. The simulations follow the formation and dissociation of molecular hydrogen and include star formation only in cold molecular gas. The molecular gas is more concentrated toward the center of galaxies than the atomic gas, and as a consequence, the resulting stellar distribution is very compact. For halos with total mass above 10{sup 11} M{sub Sun }, the median half-mass radius of the stellar disks is 0.8 kpc at z Almost-Equal-To 3. The vertical structure of the molecular disk is much thinner than that of the atomic neutral gas. Relative to the non-radiative run, the inner regions of the dark matter halo change shape from prolate to mildly oblate and align with the stellar disk. However, we do not find evidence for a significant fast-rotating 'dark disk' of dark matter around the stellar disk. The outer halo regions retain the orientation acquired during accretion and mergers and are significantly misaligned with the inner regions. The radial profile of the dark matter halo contracts in response to baryon dissipation, establishing an approximately isothermal profile throughout most of the halo. This effect can be accurately described by a modified model of halo contraction. The angular momentum of a fixed amount of inner dark matter is approximately conserved over time, while in the dissipationless case most of it is transferred outward during mergers. The conservation of the dark matter angular momentum provides supporting evidence for the validity of the halo contraction model in a hierarchical galaxy formation process.

79 ASTRONOMY AND ASTROPHYSICS↗

Thin Films of a Main Chain Columnar Liquid Crystal: Studies of Structure, Phase Transitions and Alignment

The structure of thin films of poly(di-n-propylsiloxane), PDPS, was studied with a combination of optical and atomic force microscopy, electron diffraction, and grazing incidence X-ray diffraction. Two different morphological features are observed in the mesomorphic films. The lamellar ribbons are composed of the chains oriented parallel to the plane of the substrate in which the reciprocal space 10 vector is vertical. The other feature with a circular symmetry, the cylindrite, contains the chains parallel to the substrate normal. The cylindrites and needles are essentially the same mesomorphic lamellae that develop differently under the conditions of confinement. The crystallization of PDPS films does not change the gross morphological features developed during the mesophase formation and mainly proceeds via epitaxial growth of the {alpha}-crystal on the parent mesophase. Spontaneous alignment of the mesomorphic PDPS films on the PTFE-rubbed substrates allows fabricating highly crystalline inorganic polymer surfaces oriented on the scale of centimeters.

36 MATERIALS SCIENCE↗

Microfocusing at the PG1 beamline at FLASH

The Kirkpatrick–Baez (KB) refocusing mirror system installed at the PG1 branch of the plane-grating monochromator beamline at the soft X-ray/XUV free-electron laser in Hamburg (FLASH) is designed to provide tight aberration-free focusing down to 4 µm × 6 µm full width at half-maximum (FWHM) on the sample. Such a focal spot size is mandatory to achieve ultimate resolution and to guarantee best performance of the vacuum-ultraviolet (VUV) off-axis parabolic double-monochromator Raman spectrometer permanently installed at the PG1 beamline as an experimental end-station. The vertical beam size on the sample of the Raman spectrometer, which operates without entrance slit, defines and limits the energy resolution of the instrument which has an unprecedented design value of 2 meV for photon energies below 70 eV and about 15 meV for higher energies up to 200 eV. In order to reach the designed focal spot size of 4 µm FWHM (vertically) and to hold the highest spectrometer resolution, special fully motorized in-vacuum manipulators for the KB mirror holders have been developed and the optics have been aligned employing wavefront-sensing techniques as well as ablative imprints analysis. Lastly, aberrations like astigmatism were minimized. In this article the design and layout of the KB mirror manipulators, the alignment procedure as well as microfocus optimization results are presented.

43 PARTICLE ACCELERATORS↗

Strain-driven alignment of In nanocrystals on InGaAs quantum dot arrays and coupled plasmon-quantum dot emission

We report the alignment of In nanocrystals on top of linear InGaAs quantum dot (QD) arrays formed by self-organized anisotropic strain engineering on GaAs (100) by molecular beam epitaxy. The alignment is independent of a thin GaAs cap layer on the QDs revealing its origin is due to local strain recognition. This enables nanometer-scale precise lateral and vertical site registration between the QDs and the In nanocrystals and arrays in a single self-organizing formation process. The plasmon resonance of the In nanocrystals overlaps with the high-energy side of the QD emission leading to clear modification of the QD emission spectrum.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Proton reconstruction with the TOTEM Roman pot detectors for high- β * LHC data

The TOTEM Roman pot detectors are used to reconstruct the transverse momentum of scattered protons and to estimate the transverse location of the primary interaction. This paper presents new methods of track reconstruction, measurements of strip-level detection efficiencies, cross-checks of the LHC beam optics, and detector alignment techniques, along with their application in the selection of signal collision events. The track reconstruction is performed by exploiting hit cluster information through a novel method using a common polygonal area in the intercept-slope plane. The technique is applied in the relative alignment of detector layers with μm precision. A tag-and-probe method is used to extract strip-level detection efficiencies. The alignment of the Roman pot system is performed through time-dependent adjustments, resulting in a position accuracy of 3 μm in the horizontal and 60 μm in the vertical directions. The goal is to provide an optimal reconstruction tool for central exclusive physics analyses based on the high-β* data-taking period at $\sqrt({s})$ = 13 TeV in 2018.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Mineralogy, fabric and deformation domains in D" across the southwestern border of the African LLSVP

Recent advances in seismic anisotropy studies that jointly use reflections and shear wave splitting have proven to place tight constraints on the plausible anisotropic and deformation scenarios in the D" region. We apply this novel methodology to a large area of the D" region beneath the South Atlantic, in proximity to and within the African large low seismic velocity province (LLSVP). This area of the mantle is characterized by a transition from fast to slow seismic velocity anomalies and it is thought to be the location of deep-seated plumes responsible for hotspot volcanism. Attempting to probe mantle composition and deformation along the LLSVP borders may provide key information on mantle dynamics. By analysing seismic phases sampling this region, we detect a D" discontinuity over a large area beneath the South Atlantic, with inferred depth ranges ~170 to ~240 km above the core–mantle boundary. We find evidence for a D" reflector within the area of the LLSVP. Shear wave splitting observations suggest that anisotropy is present in this region of the mantle, in agreement with previous studies that partially sampled this region. We model the observations considering lattice- and shape-preferred orientation of materials expected in the D" region. A regional variation of mineralogy, phase transition boundaries, and deformation direction is required to explain the data. We infer two distinct domains of mineralogy and deformation: aligned post-perovskite outside the LLSVP and aligned bridgmanite within the LLSVP. Finally, the scenario depicted by this study agrees well with the current hypotheses for the composition of the LLSVP and with the prevalence of vertical deformation directions expected to occur along the LLSVPs borders.

58 GEOSCIENCES↗

Magnetic and electronic properties of La{sub 0.7}Ca{sub 0.3}MnO{sub 3}/h-YMnO{sub 3} bilayer

La{sub 0.7}Ca{sub 0.3}MnO{sub 3}/h-YMnO{sub 3} (h ∼ hexagonal) bilayer thin films are grown using pulsed laser deposition technique and magnetic/band-offset measurements are performed to explore the magnetic/electronic properties. The bilayer displays the signatures of the ferromagnetic (FM) La{sub 0.7}Ca{sub 0.3}MnO{sub 3} layer and antiferromagnetic (AFM) h-YMnO{sub 3} layer. The uncompensated spins at the interface of FM/AFM layers caused exchange bias effect. The vertical and horizontal shift in field cooled isothermal magnetization curves below the AFM transition temperature shows dependence on the sign of the cooling magnetic field. Type-II band alignment at the interface of bilayer is realized through valence band offset and conduction band offset values estimated from the photoemission results.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Vertically Oriented Hexagonal Mesoporous Films Formed Through Nanometre-Scale Epitaxy

Polymer- and surfactant-templated mesoporous inorganic materials offer a unique combination of controllable nanoscale architecture, materials variation and low-cost solution processing. Inorganic materials can be produced with a range of periodic pore structures, with feature size ranging from 2 to 30 nm, and from a diverse set of materials. Unfortunately in thin-film form, the pores of the ubiquitous hexagonal honeycomb phase tend to lie in the plane of the substrate making these materials unsuitable for applications where diffusion into the pores is required. Here, we show that nanometre-scale epitaxy on a patterned substrate can be used to form vertically oriented pores in honeycomb-structured films. We use the surface of cubic mesoporous films to form the pattern; as such, our method does not sacrifice the simple processing advantages of a self-assembled system. A precise lattice match between the hexagonal and cubic films is needed for vertical orientation, a condition that can be achieved using mixed templates or selective pore swelling. Pore orientation is characterized by a combination of microscopy and diffraction. Here, we present alignment data on oriented nanopores in the 10--15 nm range, but the method should be applicable across the 2--30 nm pore size range of these self-organized materials.

36 MATERIALS SCIENCE↗

Set Up and Test Results for a Vibrating Wire System for Quadrupole Fiducialization

Quadrupoles will be placed between the undulator segments in LCLS to keep the electron beam focused as it passes through. The quadrupoles will be assembled with their respective undulator segments prior to being placed into the tunnel. Beam alignment will be used to center the quadrupoles, along with the corresponding undulators, on the beam. If there is any displacement between the undulator and the quadrupole axes in the assemblies, the beam will deviate from the undulator axis. If it deviates by more than 80{micro}m in vertical or 140{micro}m in horizontal directions, the undulator will not perform as required by LCLS. This error is divided between three sources: undulator axis fiducialization, quadrupole magnetic axis fiducialization, and assembly of the two parts. In particular, it was calculated that the quadrupole needs to be fiducialized to within 25{micro}m in both vertical and horizontal directions. A previous study suggested using a vibrating wire system for finding the magnetic axis of a quadrupole. The study showed that the method has high sensitivity (up to 1{micro}m) and laid out guidelines for constructing it. There are 3 steps in fiducializing the quadrupole with the vibrating wire system. They are positioning the wire at the magnet center (step 1), finding the wire with position detectors (step 2), and finding the quadrupole tooling ball positions relative to the position detector tooling balls (step 3). The following break up of error was suggested for the fiducialization steps: 10{micro}m for step 1 (finding the center), 20{micro}m for step 2 (finding the wire), and 10{micro}m for step 3 (tooling ball measurements). The purpose of this study is to investigate whether the vibrating wire system meets the requirements for LCLS. In particular, if it can reliably fiducialize a quadrupole magnetic center to within 25{micro}m in both vertical and horizontal directions. The behavior of individual system components is compared to the expected performance. A vibrating wire system was constructed to fiducialize the quadrupoles between undulator segments in the LCLS. This note studies the ability of the system to fulfill the fiducialization requirements.

43 PARTICLE ACCELERATORS↗

Set Up and Test Results for a Vibrating Wire System for Quadrupole Fiducialization

Quadrupoles will be placed between the undulator segments in LCLS to keep the electron beam focused as it passes through. The quadrupoles will be assembled with their respective undulator segments prior to being placed into the tunnel. Beam alignment will be used to center the quadrupoles, along with the corresponding undulators, on the beam. If there is any displacement between the undulator and the quadrupole axes in the assemblies, the beam will deviate from the undulator axis. If it deviates by more than 80{micro}m in vertical or 140{micro}m in horizontal directions, the undulator will not perform as required by LCLS. This error is divided between three sources: undulator axis fiducialization, quadrupole magnetic axis fiducialization, and assembly of the two parts. In particular, it was calculated that the quadrupole needs to be fiducialized to within 25{micro}m in both vertical and horizontal directions. A previous study suggested using a vibrating wire system for finding the magnetic axis of a quadrupole. The study showed that the method has high sensitivity (up to 1{micro}m) and laid out guidelines for constructing it. There are 3 steps in fiducializing the quadrupole with the vibrating wire system. They are positioning the wire at the magnet center (step 1), finding the wire with position detectors (step 2), and finding the quadrupole tooling ball positions relative to the position detector tooling balls (step 3). The following break up of error was suggested for the fiducialization steps: 10{micro}m for step 1 (finding the center), 20{micro}m for step 2 (finding the wire), and 10{micro}m for step 3 (tooling ball measurements). The purpose of this study is to investigate whether the vibrating wire system meets the requirements for LCLS. In particular, if it can reliably fiducialize a quadrupole magnetic center to within 25{micro}m in both vertical and horizontal directions. The behavior of individual system components is compared to the expected performance. A vibrating wire system was constructed to fiducialize the quadrupoles between undulator segments in the LCLS. This note studies the ability of the system to fulfill the fiducialization requirements.

43 PARTICLE ACCELERATORS↗

U.S. Department of Energy Reference Model Program RM2: Experimental Results

The Reference Model Project (RMP), sponsored by the U.S. Department of Energy’s (DOE) Wind and Water Power Technologies Program within the Office of Energy Efficiency & Renewable Energy (EERE), aims at expediting industry growth and efficiency by providing non-proprietary Reference Models (RM) of MHK technology designs as study objects for open-source research and development (Neary et al. 2014a,b). As part of this program, MHK turbine models were tested in a large open channel facility at the University of Minnesota’s St. Anthony Falls Laboratory (UMN - SAFL) . Reference Model 2 (RM2) is a 1:15 geometric scale dual - rotor cross flow vertical axis device with counter - rotating rotors, each with a rotor diameter d T = 0.43m and rotor height, h T = 0.323 m. RM2 is a river turbine designed for a site modeled after a reach in the lower Mississippi River near Baton Rouge, Louisiana (Barone et al. 2014) . Precise blade angular position and torque measurements were synchronized with three acoustic Doppler velocimeters (ADV) aligned with each rotor and the midpoint for RM2 . Flow conditions for each case were controlled such that depth, h = 1m, and volumetric flow rate, Q w = 2. 35m 3 s -1 , resulting in a hub height velocity of approximately U hub = 1. 2 ms -1 and blade chord length Reynolds numbers of Re c = 6 .1x10 4 . Vertical velocity profiles collected in the wake of each device from 1 to 10 rotor diameters are used to estimate the velocity recovery and turbulent characteristics in the wake, as well as the interaction of the counter-rotating rotor wakes. The development of this high resolution laboratory investigation provides a robust dataset that enables assessing computational fluid dynamics (CFD) models and their ability to accurately simulate turbulent inflow environments, device performance metrics, and to reproduce wake velocity deficit, recovery and higher order turbulent statistics.

13 HYDRO ENERGY↗