Search NASA⌕ Search

SEARCH · Search NASA

Results for “APEX”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

Polished diamond X-ray lenses

High-quality bi-concave 2D focusing diamond X-ray lenses of apex-radius R = 100 µm produced via laser-ablation and improved via mechanical polishing are presented here. Both for polished and unpolished individual lenses and for stacks of ten lenses, the remaining figure errors determined using X-ray speckle tracking are shown and these results are compared with those of commercial R = 50 µm beryllium lenses that have similar focusing strength and physical aperture. For two stacks of ten diamond lenses (polished and unpolished) and a stack of eleven beryllium lenses, this paper presents measured 2D beam profiles out of focus and wire scans to obtain the beam size in the focal plane. These results are complemented with small-angle X-ray scattering (SAXS) measurements of a polished and an unpolished diamond lens. Again, this is compared with the SAXS of a beryllium lens. The polished X-ray lenses show similar figure errors to commercially available beryllium lenses. While the beam size in the focal plane is comparable to that of the beryllium lenses, the SAXS signal of the polished diamond lenses is considerably lower.

47 OTHER INSTRUMENTATION↗

Nonuniform Charge Collection in SiOx-Based Passivated-Contact Silicon Solar Cells

In this contribution, we report on the charge-collection characteristics of silicon photovoltaic devices using passivated contacts based on the c-Si/SiO x /poly-Si structure. Using electron-beam induced current (EBIC) imaging in plan-view and cross-section orientations, we find that charge collection in a device with a 1.5-nm-thick SiO x layer is fairly uniform in the p-n junction region and does not appear to be influenced by pyramidal surface texture. In contrast, a device with a 2.2-nm-thick oxide layer shows significant spatial variation in the charge-collection signal. The apexes of the pyramids exhibit reduced EBIC signal whereas the valleys between adjacent pyramids show the strongest collection. Our results indicate that charge collection in c-Si/SiO x /poly-Si structures can be influenced by both the properties of the SiO x layer and surface texture.

14 SOLAR ENERGY↗

On a High-Mirror Stellarator Reactor Exploratory Concept With Neutrons Concentrated on Centrifuge Liquids

In the framework of fusion energy research based on magnetic confinement, stellarators allow numerous degrees of freedom for the design of the magnetic trap and plasma shape. Taking advantage of these features, some plasma shapes might benefit several of the many integrated elements involved in commercial fusion reactors, like, e.g., decreasing the number, mass and complexity of replaced activated in-vessel components (IVC) (i.e., by using liquids), extraction of large power, tritium generation, and remote maintenance. Certainly, free-surface liquid materials were proposed for tokamaks and field-reversed configuration (FRC) to try to improve some of such elements, i.e., in advanced power extraction (APEX) studies. Some reactor-relevant quasi-isodynamic (QI) magnetic configurations exhibit a relatively straight sector of plasma and high magnetic mirror. The combination of those elements and possibilities in a single stellarator reactor concept might have some advantages, in spite of the uncertainties due to the current low technological readiness level (TRL). The proposed and studied reactor concept is based on a vacuum vessel having short curved sectors and longer wide cylindrical sectors, which encloses a high-mirror low-vertical-excursion magnetic configuration, and swirling liquids or rotating cylinders, which centrifuge molten Li salts located at the low field region. Thus, the molten salts (if possible covered by a thin layer of liquid lithium) would be located on the internal perimeter of the cylinder, to act as particle exhaust (except for helium), neutron power extractor, and tritium breeder. The high-mirror feature tries to concentrate the neutron power at the cylindrical sectors, which might avoid using breeding materials at the curved sectors. The different elements of the concept are exploratorily studied and defined, and the difficulties assessed.

centrifuge↗

Intrinsic and extrinsic factors interact during development to influence telomere length in a long‐lived reptile

Abstract The mechanisms connecting environmental conditions to plasticity in biological aging trajectories are fundamental to understanding individual variation in functional traits and life history. Recent findings suggest that telomere biology is especially dynamic during early life stages and has long‐term consequences for subsequent reproduction and survival. However, our current understanding is mostly derived from studies investigating ecological and anthropogenic factors separately, leaving the effects of complex environmental interactions unresolved. American alligators ( Alligator mississippiensis ) are long‐lived apex predators that rely on incubation temperature during a discrete period during development and endocrine cues to determine sex, making them especially vulnerable to current climatic variability and exposure to anthropogenic contaminants interfering with hormone function. Here, we combine field studies with a factorial design to understand how the developmental environment, along with intrinsic biological variation contribute to persistent telomere variation. We found that exposure to a common endocrine disrupting contaminant, DDE, affects telomere length, but that the directionality is highly dependent upon incubation temperature. Variation in hatchling growth, underlies a strong clutch effect. We also assess concentrations of a panel of glucocorticoid hormones and find that contaminant exposure elicits an increase in circulating glucocorticoids. Consistent with emerging evidence linking stress and aging trajectories, GC levels also appear to trend with shorter telomere length. Thus, we add support for a mechanistic link between contaminants and glucocorticoid signalling, which interacts with ecological aspects of the developmental environment to alter telomere dynamics.

Bae, Junsoo↗

Nanofabrication of sharp diamond tips by e-beam lithography and inductively coupled plasma reactive ion etching.

Ultrasharp diamond tips make excellent atomic force microscopy probes, field emitters, and abrasive articles due to diamond's outstanding physical properties, i.e., hardness, low friction coefficient, low work function, and toughness. Sharp diamond tips are currently fabricated as individual tips or arrays by three principal methods: (1) focused ion beam milling and gluing onto a cantilever of individual diamond tips, (2) coating silicon tips with diamond films, or (3) molding diamond into grooves etched in a sacrificial substrate, bonding the sacrificial substrate to another substrate or electrodepositing of a handling chip, followed by dissolution of the sacrificial substrate. The first method is tedious and serial in nature but does produce very sharp tips, the second method results in tips whose radius is limited by the thickness of the diamond coating, while the third method involves a costly bonding and release process and difficulties in thoroughly filling the high aspect ratio apex of molding grooves with diamond at the nanoscale. To overcome the difficulties with these existing methods, this article reports on the feasibility of the fabrication of sharp diamond tips by direct etching of ultrananocrystalline diamond (UNCD{reg_sign}) as a starting and structural material. The UNCD is reactive ion etched using a cap-precursor-mask scheme. An optimized etching recipe demonstrates the formation of ultrasharp diamond tips ({approx} 10 nm tip radius) with etch rates of 650 nm/min.

36 MATERIALS SCIENCE↗

Electric discharge initiation in water with gas bubbles: A time scale approach

High voltage nanosecond pulse driven electric discharges in de-ionized water with an argon bubble suspended between two electrodes were experimentally investigated. Two electrode configurations were used to temporally resolve the time scales of the discharge from the applied voltage rise time (7 ns), through the end of the first pulse (∼30 ns), and longer (>50 ns). We found that, in positive and negative applied voltage polarities, discharge initiates in the water at the tip of the anode. The discharge in the water rapidly extends (∼104 m/s) to the apex of the bubble and light emitted from inside the bubble begins to form. The steep rate of rise of the applied voltage (dV/dt<4 kV/ns) and the short time for the development of discharge in the water suggest that cavitation is a likely mechanism for discharge initiation and propagation in water. In addition, the short duration of the applied voltage pulse results in only a partial Townsend discharge inside the bubble.

Sponsel, Nicholas L. (ORCID:0000000181729378)↗

Respiratory motion effects on whole breast helical tomotherapy

The effects of intrafraction respiratory motion on nonhelical intensity-modulated radiotherapy have been well addressed in the literature, both theoretically and experimentally. However, the consequences of respiratory motion on helical tomotherapy, for patient-specific treatment plans, are less well known. Parameters specific to this treatment modality such as pitch, gantry speed, and degree of modulation may play prominent roles in radiation delivery with respect to intrafraction respiratory motion. This phantom-based study specifically addressed the effects of intrafraction respiratory motion on whole breast helical tomotherapy. A device capable of driving an acrylic phantom with reproducible, one-dimensional, anterior-posterior motion resembling a sinusoid of 4.6 mm crest-trough amplitude was developed. A plan to irradiate the corner of an acrylic phantom using parameters typical of a whole breast helical tomotherapy technique was developed using the TomoTherapy Hi-Art-II System registered . The treatment was delivered to the phantom, with Kodak EDR2 film in the axial plane, for each of the following conditions: (i) phantom at 270 deg. initial sinusoidal phase and 12 cycles/min motion, (ii) phantom at 270 deg. initial sinusoidal phase and 18 cycles/min motion, and (iii)-(v) phantom at 18 cycles/min motion with 0 deg., 90 deg., and 180 deg. initial sinusoidal phases. A measure of technique reproducibility was also performed for several irradiations with the phantom static at 270 deg. initial sinusoidal phase. Films were processed using a Kodak MIN-R mammography film processor, scanned with a Vidar NXR-16 Dosimetry Pro scanner and analyzed with RIT113 v.4.2 software. Films were compared to a reference film irradiated under the conditions of no motion and 270 deg. sinusoidal phase. For all comparisons, 5% dose difference threshold, 3% dose difference and 2 mm distance-to-agreement gamma analysis, and isodose plots were generated. The results of this study show a small area of greater than 5% decrease in dose at the phantom's anterior surface and a 1.5-3 mm posterior-medial shift of isodose lines in the penumbral and apex regions of the PTV. Frequency and phase effects are apparent within the PTV where dose varies with high spatial frequency. As the reference film was produced by delivering the treatment plan to the phantom static and in the position corresponding to maximum expiration, results are representative of extreme deviations between planned and delivered dose with respect to sinusoidal motion of clinically relevant magnitudes and frequencies.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Prostate brachytherapy postimplant dosimetry: Seed orientation and the impact of dosimetric anisotropy in stranded implants

Purpose: In postimplant dosimetry for prostate brachytherapy, dose is commonly calculated using the TG-43 1D formalism, because seed orientations are difficult to determine from CT images, the current standard for the procedure. However, the orientation of stranded seeds soon after implantation is predictable, as these seeds tend to maintain their relative spacing, and orient themselves along the implant trajectory. The aim of this study was to develop a method for determining seed orientations from reconstructed strand trajectories, and to use this information to investigate the dosimetric impact of applying the TG-43 2D formalism to clinical postimplant analysis. Methods: Using in-house software, the preplan to postimplant seed correspondence was determined for a cohort of 30 patients during routine day-0 CT-based postimplant dosimetry. All patients were implanted with stranded-seed trains. Spline curves were fit to each set of seeds composing a strand, with the requirement that the distance along the spline between seeds be equal to the seed spacing within the strand. The orientations of the seeds were estimated by the tangents to the spline at each seed centroid. Dose distributions were then determined using the 1D and 2D TG-43 formalisms. These were compared using the TG-137 recommended dose metrics for the prostate, prostatic urethra, and rectum. Results: Seven hundred and sixty one strands were analyzed in total. Defining the z-axis to be cranial-positive and the x-axis to be left-lateral positive in the CT coordinate system, the average seed had an inclination of 21 deg. {+-} 10 deg. and an azimuth of -81 deg. {+-} 57 deg. These values correspond to the average strand rising anteriorly from apex to base, approximately parallel to the midsagittal plane. Clinically minor but statistically significant differences in dose metrics were noted. Compared to the 2D calculation, the 1D calculation underestimated prostate V100 by 1.1% and D90 by 2.3 Gy, while overestimating V150 and V200 by 1.6% and 1.3%, respectively. Urethral and rectal dose quantifiers tended to be underestimated by the 1D calculation. The most pronounced differences were in the urethral D30 and rectal D2cc, which rose by 3.8 and 1.9 Gy, respectively, using the 2D calculation. The total volume of the 100% isodose region as a percentage of the prostate volume was found to increase by 0.4%. Conclusions: Stranded seeds in the supine patient are not oriented in a uniformly random manner, nor are they aligned along the axis of the CT scanner. Instead, this study identified a consistent anterior pitch that is likely attributable to differences in patient pose between implant and CT imaging. The angle of the ultrasound probe with respect to the patient during implant may have also been a contributing factor. The dose metrics derived using the 1D formalism were found to be within 2%, on average, of those derived using the 2D formalism. For greater accuracy, 2D dosimetry can be pursued using the strand-fitting method described in this work. If a 1D representation is used, integrating over the empirically determined seed orientation density reported here may be more appropriate than assuming that seed inclinations are distributed uniformly.

61 RADIATION PROTECTION AND DOSIMETRY↗

Monte Carlo dosimetry for {sup 103}Pd, {sup 125}I, and {sup 131}Cs ocular brachytherapy with various plaque models using an eye phantom

Purpose: To investigate dosimetry for ocular brachytherapy for a range of eye plaque models containing{sup 103}Pd, {sup 125}I, or {sup 131}Cs seeds with model-based dose calculations. Methods: Five representative plaque models are developed based on a literature review and are compared to the standardized COMS plaque, including plaques consisting of a stainless steel backing and acrylic insert, and gold alloy backings with: short collimating lips and acrylic insert, no lips and silicone polymer insert, no lips and a thin acrylic layer, and individual collimating slots for each seed within the backing and no insert. Monte Carlo simulations are performed using the EGSnrc user-code BrachyDose for single and multiple seed configurations for the plaques in water and within an eye model (including nonwater media). Simulations under TG-43 assumptions are also performed, i.e., with the same seed configurations in water, neglecting interseed and plaque effects. Maximum and average doses to ocular structures as well as isodose contours are compared for simulations of each radionuclide within the plaque models. Results: The presence of the plaque affects the dose distribution substantially along the plaque axis for both single seed and multiseed simulations of each plaque design in water. Of all the plaque models, the COMS plaque generally has the largest effect on the dose distribution in water along the plaque axis. Differences between doses for single and multiple seed configurations vary between plaque models and radionuclides. Collimation is most substantial for the plaque with individual collimating slots. For plaques in the full eye model, average dose in the tumor region differs from those for the TG-43 simulations by up to 10% for{sup 125}I and {sup 131}Cs, and up to 17% for {sup 103}Pd, and in the lens region by up to 29% for {sup 125}I, 34% for {sup 103}Pd, and 28% for {sup 131}Cs. For the same prescription dose to the tumor apex, the lowest doses to critical ocular structures are generally delivered with plaques containing {sup 103}Pd seeds. Conclusions: The combined effects of ocular and plaque media on dose are significant and vary with plaque model and radionuclide, suggesting the importance of model-based dose calculations employing accurate ocular and plaque media and geometries for eye plaque brachytherapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-D-9A-06: 3D Localization of Neurovascular Bundles Through MR-TRUS Registration in Prostate Radiotherapy

Purpose: Erectile dysfunction (ED) is the most common complication of prostate-cancer radiotherapy (RT) and the major mechanism is radiation-induced neurovascular bundle (NVB) damage. However, the localization of the NVB remains challenging. This study's purpose is to accurately localize 3D NVB by integrating MR and transrectal ultrasound (TRUS) images through MR-TRUS fusion. Methods: T1 and T2-weighted MR prostate images were acquired using a Philips 1.5T MR scanner and a pelvic phase-array coil. The 3D TRUS images were captured with a clinical scanner and a 7.5 MHz biplane probe. The TRUS probe was attached to a stepper; the B-mode images were captured from the prostate base to apex at a 1-mm step and the Doppler images were acquired in a 5-mm step. The registration method modeled the prostate tissue as an elastic material, and jointly estimated the boundary condition (surface deformation) and the volumetric deformations under elastic constraint. This technique was validated with a clinical study of 7 patients undergoing RT treatment for prostate cancer. The accuracy of our approach was assessed through the locations of landmarks, as well as previous ultrasound Doppler images of patients. Results: MR-TRUS registration was successfully performed for all patients. The mean displacement of the landmarks between the post-registration MR and TRUS images was 1.37±0.42 mm, which demonstrated the precision of the registration based on the biomechanical model; and the NVB volume Dice Overlap Coefficient was 92.1±3.2%, which demonstrated the accuracy of the NVB localization. Conclusion: We have developed a novel approach to improve 3D NVB localization through MR-TRUS fusion for prostate RT, demonstrated its clinical feasibility, and validated its accuracy with ultrasound Doppler data. This technique could be a useful tool as we try to spare the NVB in prostate RT, monitor NBV response to RT, and potentially improve post-RT potency outcomes.

60 APPLIED LIFE SCIENCES↗

SU-E-P-08: Alarming Range of Seed Activities Ordered for I-125 Plaque Brachytherapy

Purpose: To investigate the variation in I-125 seed activities ordered by various clinics for their plaque brachytherapy cases under a standardized set of assumptions. Methods: A majority of the plaque programs in North America were contacted and a survey was designed to give a few standardized cases to allow inter-comparison of seed activities ordered. Tumor dose, treatment duration, number of seeds, plaque, and tumor apex were held constant in order to reveal differences in prescription point, seed type, and seed activity. Results: While the survey is presently underway, preliminary results show alarmingly wide variations between centers. Differences up to 45% have been found with 15% differences being common. Conclusion: Though knowledge of the TG-43 dose calculation formalism is common, a number of factors in the field of plaque brachytherapy lead to alarming differences in activity of I-125 seeds being ordered for a given tumor. Knowledge of the present reality of widely varying treatment activities, and thus doses to tumor and normal structures, should serve as motivation for centers involved in this modality to review their programs with others in the community and share their experiences.

60 APPLIED LIFE SCIENCES↗

Patient position alters attenuation effects in multipinhole cardiac SPECT

Purpose: Dedicated cardiac cameras offer improved sensitivity over conventional SPECT cameras. Sensitivity gains are obtained by large numbers of detectors and novel collimator arrangements such as an array of multiple pinholes that focus on the heart. Pinholes lead to variable amounts of attenuation as a source is moved within the camera field of view. This study evaluated the effects of this variable attenuation on myocardial SPECT images. Methods: Computer simulations were performed for a set of nine point sources distributed in the left ventricular wall (LV). Sources were placed at the location of the heart in both an anthropomorphic and a water-cylinder computer phantom. Sources were translated in x, y, and z by up to 5 cm from the center. Projections were simulated with and without attenuation and the changes in attenuation were compared. A LV with an inferior wall defect was also simulated in both phantoms over the same range of positions. Real camera data were acquired on a Discovery NM530c camera (GE Healthcare, Haifa, Israel) for five min in list-mode using an anthropomorphic phantom (DataSpectrum, Durham, NC) with 100 MBq of Tc-99m in the LV. Images were taken over the same range of positions as the simulations and were compared based on the summed perfusion score (SPS), defect width, and apparent defect uptake for each position. Results: Point sources in the water phantom showed absolute changes in attenuation of ≤8% over the range of positions and relative changes of ≤5% compared to the apex. In the anthropomorphic computer simulations, absolute change increased to 20%. The changes in relative attenuation caused a change in SPS of <1.5 for the water phantom but up to 4.2 in the anthropomorphic phantom. Changes were larger for axial than for transverse translations. These results were supported by SPS changes of up to six seen in the physical anthropomorphic phantom for axial translations. Defect width was also seen to significantly increase. The position-dependent changes were removed with attenuation correction. Conclusions: Translation of a source relative to a multipinhole camera caused only small changes in homogeneous phantoms with SPS changing <1.5. Inhomogeneous attenuating media cause much larger changes to occur when the source is translated. Changes in SPS of up to six were seen in an anthropomorphic phantom for axial translations. Attenuation correction removes the position-dependent changes in attenuation.

60 APPLIED LIFE SCIENCES↗

SU-E-I-75: Development of New Biological Fingerprints for Patient Recognition to Identify Misfiled Images in a PACS Server

Purpose: We are trying to develop an image-searching technique to identify misfiled images in a picture archiving and communication system (PACS) server by using five biological fingerprints: the whole lung field, cardiac shadow, superior mediastinum, lung apex, and right lower lung. Each biological fingerprint in a chest radiograph includes distinctive anatomical structures to identify misfiled images. The whole lung field was less effective for evaluating the similarity between two images than the other biological fingerprints. This was mainly due to the variation in the positioning for chest radiographs. The purpose of this study is to develop new biological fingerprints that could reduce influence of differences in the positioning for chest radiography. Methods: Two hundred patients were selected randomly from our database (36,212 patients). These patients had two images each (current and previous images). Current images were used as the misfiled images in this study. A circumscribed rectangular area of the lung and the upper half of the rectangle were selected automatically as new biological fingerprints. These biological fingerprints were matched to all previous images in the database. The degrees of similarity between the two images were calculated for the same and different patients. The usefulness of new the biological fingerprints for automated patient recognition was examined in terms of receiver operating characteristic (ROC) analysis. Results: Area under the ROC curves (AUCs) for the circumscribed rectangle of the lung, upper half of the rectangle, and whole lung field were 0.980, 0.994, and 0.950, respectively. The new biological fingerprints showed better performance in identifying the patients correctly than the whole lung field. Conclusion: We have developed new biological fingerprints: circumscribed rectangle of the lung and upper half of the rectangle. These new biological fingerprints would be useful for automated patient identification system because they are less affected by positioning differences during imaging.

60 APPLIED LIFE SCIENCES↗

SU-E-J-79: Evaluation of Prostate Volume Changes During Radiotherapy Using Implanted Markers and On-Board Imaging

Purpose: To evaluate prostate volume changes during radiation therapy using implanted gold markers and on-board imaging. Methods: Twenty-five patients were included who underwent an implantation of three gold markers. Cartesian coordinates of markers were assessed in kV-images. The coordinates of centers of two markers were measured on kV-images from the center of the marker at the apex which was reference. The distances between the markers were extrapolated from the coordinates using the Euclid formula. The radius of the sphere through markers was calculated using sinus theorem. The prostate volume for the first and last fraction was substituted with a sphere model and was calculated for each patient. The t-test was used for analysis. Results: The mean prostate volume for first and last fraction was 24.65 and 20.87 cc, respectively (p≤0.05). The prostate volume was smaller for 23 patients, whereas there was an expansion for 2 patients. Fifteen patients had androgen deprivation during radiotherapy (H group) and ten did not (NH group). The mean prostate volume for the first and last fraction for the NH group was 30.73 cc and 24.89 cc and for the H group 20.84 cc and 18.19 cc, respectively. There was a 15.8% volume change during treatment for the NH group and 12.2% for the H group, but the difference was not statistically significant. The radius difference of the theoretical sphere for the first and last fraction was 0.98 mm (range, 0.09–2.95 mm) and remained below 2 mm in 88% of measurements. Conclusion: There was a significant volume change during prostate radiotherapy. The difference between H group and NH group was not significant. The radius changes did not exceed 3 mm and it was below adaptive treatment requirements. Our results indicate that prostate volume changes during treatment should be taken into account during contouring and treatment planning.

60 APPLIED LIFE SCIENCES↗

SU-E-T-149: Brachytherapy Patient Specific Quality Assurance for a HDR Vaginal Cylinder Case

Purpose: Commonly Ir-192 HDR treatment planning system commissioning is only based on a single absolute measurement of source activity supplemented by tabulated parameters for multiple factors without independent verification that the planned distribution corresponds to the actual delivered dose. The purpose on this work is to present a methodology using Gafchromic film with a statistically valid calibration curve that can be used to validate clinical HDR vaginal cylinder cases by comparing the calculated plan dose distribution in a plane with the corresponding measured planar dose. Methods: A vaginal cylinder plan was created with Oncentra treatment planning system. The 3D dose matrix was exported to a Varian Eclipse work station for convenient extraction of a 2D coronal dose plane corresponding to the film position. The plan was delivered with a sheet of Gafchromic EBT3 film positioned 1mm from the catheter using an Ir-192 Nucletron HDR source. The film was then digitized with an Epson 10000 XL color scanner. Film analysis is performed with MatLab imaging toolbox. A density to dose calibration curve was created using TG43 formalism for a single dwell position exposure at over 100 points for statistical accuracy. The plan and measured film dose planes were registered using a known dwell position relative to four film marks. The plan delivered 500 cGy to points 2 cm from the sources. Results: The distance to agreement of the 500 cGy isodose between the plan and film measurement laterally was 0.5 mm but can be as much as 1.5 mm superior and inferior. The difference between the computed plan dose and film measurement was calculated per pixel. The greatest errors up to 50 cGy are near the apex. Conclusion: The methodology presented will be useful to implement more comprehensive quality assurance to verify patient-specific dose distributions.

60 APPLIED LIFE SCIENCES↗

SU-E-T-443: Geometric Uncertainties in Eye Plaque Dosimetry for a Fully Loaded 16 Mm COMS Plaque

Purpose: To determine the effect of geometric uncertainties in the seed positions in a COMS eye plaque on the central axis (CAX) dose. Methods: A Silastic insert was placed into a photopolymer 3D printed 16 mm COMS plaque, which was then positioned onto a custom-designed PMMA eye phantom. High resolution 3D images were acquired of the setup using a Siemens Inveon microPET/CT scanner. Images were acquired with the plaque unloaded and loaded with IsoAid I-125 seed shells (lack of silver core to minimize metal artifacts). Seed positions and Silastic thickness beneath each slot were measured. The measured seed coordinates were used to alter the seed positions within a standard 16 mm COMS plaque in Plaque Simulator v5.7.3 software. Doses along the plaque CAX were compared for the original and modified plaque coordinates using 3.5 mCi seeds with treatment times set to deliver 70 Gy to tumour apexes of 3.5, 5, and 10 mm height. Results: The majority of seeds showed length-wise displacement, and all seeds showed displacement radially outward from the eye center. The average radial displacement was 0.15 mm larger than the expected 1.4 mm offset, approximately half of which was due to increased Silastic thickness beneath each slot. The CAX doses for the modified seed positions were consistently lower for all tumour heights due to geometric displacement of the seeds; dose differences were found to increase to a maximum of 2.6% at a depth of ∼10 mm, after which they decreased due to the inverse square dose fall-off minimizing this effect. Conclusion: This work presents initial results of a broader dosimetric uncertainty evaluation for fully loaded COMS eye plaques and demonstrates the effects of seed positioning uncertainties. The small shifts in seed depths had noticeable effects on the CAX doses indicating the importance of careful Silastic loading. Funding provided by Alberta Cancer Foundation Grant #26655, Vanier Canada Graduate Scholarship, and Alberta Innovates Health Sciences Graduate Studentship.

60 APPLIED LIFE SCIENCES↗

TU-CD-BRA-11: Application of Bone Suppression Technique to Inspiratory/expiratory Chest Radiography

Purpose: The bone suppression technique based on advanced image processing can suppress the conspicuity of bones on chest radiographs, creating soft tissue images normally obtained by the dual-energy subtraction technique. This study was performed to investigate the usefulness of bone suppression technique in quantitative analysis of pulmonary function in inspiratory/expiratory chest radiography. Methods: Commercial bone suppression image processing software (ClearRead; Riverain Technologies) was applied to paired inspiratory/expiratory chest radiographs of 107 patients (normal, 33; abnormal, 74) to create corresponding bone suppression images. The abnormal subjects had been diagnosed with pulmonary diseases, such as pneumothorax, pneumonia, emphysema, asthma, and lung cancer. After recognition of the lung area, the vectors of respiratory displacement were measured in all local lung areas using a cross-correlation technique. The measured displacement in each area was visualized as displacement color maps. The distribution pattern of respiratory displacement was assessed by comparison with the findings of lung scintigraphy. Results: Respiratory displacement of pulmonary markings (soft tissues) was able to be quantified separately from the rib movements on bone suppression images. The resulting displacement map showed a left-right symmetric distribution increasing from the lung apex to the bottom region of the lung in many cases. However, patients with ventilatory impairments showed a nonuniform distribution caused by decreased displacement of pulmonary markings, which were confirmed to correspond to area with ventilatory impairments found on the lung scintigrams. Conclusion: The bone suppression technique was useful for quantitative analysis of respiratory displacement of pulmonary markings without any interruption of the rib shadows. Abnormal areas could be detected as decreased displacement of pulmonary markings. Inspiratory/expiratory chest radiography combined with the bone suppression technique has potential for predicting local lung function on the basis of dynamic analysis of pulmonary markings. This work was partially supported by Nakatani Foundation, Grant-in-aid for Scientific Research (C) of Ministry of Education, Culture, Sports, Science and Technology, JAPAN (Grant number : 24601007), and Nakatani Foundation, Mitsubishi Foundation, and the he Mitani Foundation for Research and Development. Yasushi Kishitani is a staff of TOYO corporation.

60 APPLIED LIFE SCIENCES↗

Multidimensional dosimetry of {sup 106}Ru eye plaques using EBT3 films and its impact on treatment planning

Purpose: The purpose of this study was to establish a method to perform multidimensional radiochromic film measurements of {sup 106}Ru plaques and to benchmark the resulting dose distributions against Monte Carlo simulations (MC), microdiamond, and diode measurements. Methods: Absolute dose rates and relative dose distributions in multiple planes were determined for three different plaque models (CCB, CCA, and COB), and three different plaques per model, using EBT3 films in an in-house developed polystyrene phantom and the MCNP6 MC code. Dose difference maps were generated to analyze interplaque variations for a specific type, and for comparing measurements against MC simulations. Furthermore, dose distributions were validated against values specified by the manufacturer (BEBIG) and microdiamond and diode measurements in a water scanning phantom. Radial profiles were assessed and used to estimate dosimetric margins for a given combination of representative tumor geometry and plaque size. Results: Absolute dose rates at a reference depth of 2 mm on the central axis of the plaque show an agreement better than 5% (10%) when comparing film measurements (MCNP6) to the manufacturer’s data. The reproducibility of depth-dose profile measurements was <7% (2 SD) for all investigated detectors and plaque types. Dose difference maps revealed minor interplaque deviations for a specific plaque type due to inhomogeneities of the active layer. The evaluation of dosimetric margins showed that for a majority of the investigated cases, the tumor was not completely covered by the 100% isodose prescribed to the tumor apex if the difference between geometrical plaque size and tumor base ≤4 mm. Conclusions: EBT3 film dosimetry in an in-house developed phantom was successfully used to characterize the dosimetric properties of different {sup 106}Ru plaque models. The film measurements were validated against MC calculations and other experimental methods and showed a good agreement with data from BEBIG well within published tolerances. The dosimetric information as well as interplaque comparison can be used for comprehensive quality assurance and for considerations in the treatment planning of ophthalmic brachytherapy.

60 APPLIED LIFE SCIENCES↗