Search NASA⌕ Search

SEARCH · Search NASA

Results for “Accuracy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

OSLD energy response performance and dose accuracy at 24 - 1250 keV: Comparison with TLD-100H and TLD-100

OSLD was evaluated in terms of energy response and accuracy of the measured dose in comparison with TLD-100H and TLD-100. The OSLD showed a better energy response performance for H{sub p}(10) whereas for H{sub p}(0.07), TLD-100H is superior than the others. The OSLD dose accuracy is comparable with the other two dosimeters since it fulfilled the requirement of the ICRP trumpet graph analysis.

61 RADIATION PROTECTION AND DOSIMETRY↗

Accuracy evaluation of a Compton X-ray spectrometer with bremsstrahlung X-rays generated by a 6 MeV electron bunch

A Compton-scattering-based X-ray spectrometer is developed to obtain the energy distribution of fast electrons produced by intense laser and matter interactions. Bremsstrahlung X-rays generated by fast electrons in a material are used to measure fast electrons’ energy distribution in matter. In the Compton X-ray spectrometer, X-rays are converted into recoil electrons by Compton scattering in a converter made from fused silica glass, and a magnet-based electron energy analyzer is used to measure the energy distribution of the electrons that recoil in the direction of the incident X-rays. The spectrum of the incident X-rays is reconstructed from the energy distribution of the recoil electrons. The accuracy of this spectrometer is evaluated using a quasi-monoenergetic 6 MeV electron bunch that emanates from a linear accelerator. An electron bunch is injected into a 1.5 mm thick tungsten plate to produce bremsstrahlung X-rays. The spectrum of these bremsstrahlung X-rays is obtained in the range from 1 to 9 MeV. The energy of the electrons in the bunch is estimated using a Monte Carlo simulation of particle-matter interactions. The result shows that the spectrometer's energy accuracy is ±0.5 MeV for 6.0 MeV electrons.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Accuracy of an infrared marker-based patient positioning system (ExacTrac®) for stereotactic body radiotherapy in localizing the planned isocenter using fiducial markers

Stereotactic Body Radiation Therapy (SBRT) requires a controlled immobilization and position monitoring of patient and target. The purpose of this work is to analyze the performance of the imaging system ExacTrac® (ETX) using infrared and fiducial markers. Materials and methods: In order to assure the accuracy of isocenter localization, a Quality Assurance procedure was applied using an infrared marker-based positioning system. Scans were acquired of an inhouse-agar gel and solid water phantom with infrared spheres. In the inner part of the phantom, three reference markers were delineated as reference and one pellet was place internally; which was assigned as the isocenter. The iPlan® RT Dose treatment planning system. Images were exported to the ETX console. Images were acquired with the ETX to check the correctness of the isocenter placement. Adjustments were made in 6D the reference markers were used to fuse the images. Couch shifts were registered. The procedure was repeated for verification purposes. Results: The data recorded of the verifications in translational and rotational movements showed averaged 3D spatial uncertainties of 0.31 ± 0.42 mm respectively 0.82° ± 0.46° in the phantom and the first correction of these uncertainties were of 1.51 ± 1.14 mm respectively and 1.37° ± 0.61°. Conclusions: This study shows a high accuracy and repeatability in positioning the selected isocenter. The ETX-system for verifying the treatment isocenter position has the ability to monitor the tracing position of interest, making it possible to be used for SBRT positioning within uncertainty ≤1mm.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Quantum limits on optical phase estimation accuracy from classical rate-distortion theory

The classical information-theoretic lower bound on the distortion of a random variable upon transmission through a noisy channel is applied to quantum-optical phase estimation. An approach for obtaining Bayesian lower bounds on the phase estimation accuracy is described that employs estimates of the classical capacity of the relevant quantum-optical channels. The Heisenberg limit for lossless phase estimation is derived for arbitrary probe state and prior distributions of the phase, and shot-noise scaling of the phase accuracy is established in the presence of nonzero loss for a parallel entanglement-assisted strategy with a single probe mode.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Does DFT-SAPT method provide spectroscopic accuracy?

Ground state potential energy curves for homonuclear and heteronuclear dimers consisting of noble gas atoms from He to Kr were calculated within the symmetry adapted perturbation theory based on the density functional theory (DFT-SAPT). These potentials together with spectroscopic data derived from them were compared to previous high-precision coupled cluster with singles and doubles including the connected triples theory calculations (or better if available) as well as to experimental data used as the benchmark. The impact of midbond functions on DFT-SAPT results was tested to study the convergence of the interaction energies. It was shown that, for most of the complexes, DFT-SAPT potential calculated at the complete basis set (CBS) limit is lower than the corresponding benchmark potential in the region near its minimum and hence, spectroscopic accuracy cannot be achieved. The influence of the residual term δ(HF) on the interaction energy was also studied. As a result, we have found that this term improves the agreement with the benchmark in the repulsive region for the dimers considered, but leads to even larger overestimation of potential depth D{sub e}. Although the standard hybrid exchange-correlation (xc) functionals with asymptotic correction within the second order DFT-SAPT do not provide the spectroscopic accuracy at the CBS limit, it is possible to adjust empirically basis sets yielding highly accurate results.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Improving z-tracking accuracy in the two-photon single-particle tracking microscope

Here, we present a method that can improve the z-tracking accuracy of the recently invented TSUNAMI (Tracking of Single particles Using Nonlinear And Multiplexed Illumination) microscope. This method utilizes a maximum likelihood estimator (MLE) to determine the particle's 3D position that maximizes the likelihood of the observed time-correlated photon count distribution. Our Monte Carlo simulations show that the MLE-based tracking scheme can improve the z-tracking accuracy of TSUNAMI microscope by 1.7 fold. In addition, MLE is also found to reduce the temporal correlation of the z-tracking error. Taking advantage of the smaller and less temporally correlated z-tracking error, we have precisely recovered the hybridization-melting kinetics of a DNA model system from thousands of short single-particle trajectories in silico. Our method can be generally applied to other 3D single-particle tracking techniques.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

On the accuracy of the Padé-resummed master equation approach to dissipative quantum dynamics

Well-defined criteria are proposed for assessing the accuracy of quantum master equations whose memory functions are approximated by Padé resummation of the first two moments in the electronic coupling. These criteria partition the parameter space into distinct levels of expected accuracy, ranging from quantitatively accurate regimes to regions of parameter space where the approach is not expected to be applicable. Extensive comparison of Padé-resummed master equations with numerically exact results in the context of the spin–boson model demonstrates that the proposed criteria correctly demarcate the regions of parameter space where the Padé approximation is reliable. The applicability analysis we present is not confined to the specifics of the Hamiltonian under consideration and should provide guidelines for other classes of resummation techniques.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Assessment of the accuracy of coupled cluster perturbation theory for open-shell systems. I. Triples expansions

The accuracy at which total energies of open-shell atoms and organic radicals may be calculated is assessed for selected coupled cluster perturbative triples expansions, all of which augment the coupled cluster singles and doubles (CCSD) energy by a non-iterative correction for the effect of triple excitations. Namely, the second- through sixth-order models of the recently proposed CCSD(T–n) triples series [J. J. Eriksen et al., J. Chem. Phys. 140, 064108 (2014)] are compared to the acclaimed CCSD(T) model for both unrestricted as well as restricted open-shell Hartree-Fock (UHF/ROHF) reference determinants. By comparing UHF- and ROHF-based statistical results for a test set of 18 modest-sized open-shell species with comparable RHF-based results, no behavioral differences are observed for the higher-order models of the CCSD(T–n) series in their correlated descriptions of closed- and open-shell species. In particular, we find that the convergence rate throughout the series towards the coupled cluster singles, doubles, and triples (CCSDT) solution is identical for the two cases. For the CCSD(T) model, on the other hand, not only its numerical consistency, but also its established, yet fortuitous cancellation of errors breaks down in the transition from closed- to open-shell systems. The higher-order CCSD(T–n) models (orders n > 3) thus offer a consistent and significant improvement in accuracy relative to CCSDT over the CCSD(T) model, equally for RHF, UHF, and ROHF reference determinants, albeit at an increased computational cost.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Assessment of the accuracy of coupled cluster perturbation theory for open-shell systems. II. Quadruples expansions

We extend our assessment of the potential of perturbative coupled cluster (CC) expansions for a test set of open-shell atoms and organic radicals to the description of quadruple excitations. Namely, the second- through sixth-order models of the recently proposed CCSDT(Q–n) quadruples series [J. J. Eriksen et al., J. Chem. Phys. 140, 064108 (2014)] are compared to the prominent CCSDT(Q) and ΛCCSDT(Q) models. From a comparison of the models in terms of their recovery of total CC singles, doubles, triples, and quadruples (CCSDTQ) energies, we find that the performance of the CCSDT(Q–n) models is independent of the reference used (unrestricted or restricted (open-shell) Hartree-Fock), in contrast to the CCSDT(Q) and ΛCCSDT(Q) models, for which the accuracy is strongly dependent on the spin of the molecular ground state. By further comparing the ability of the models to recover relative CCSDTQ total atomization energies, the discrepancy between them is found to be even more pronounced, stressing how a balanced description of both closed- and open-shell species—as found in the CCSDT(Q–n) models—is indeed of paramount importance if any perturbative CC model is to be of chemical relevance for high-accuracy applications. In particular, the third-order CCSDT(Q–3) model is found to offer an encouraging alternative to the existing choices of quadruples models used in modern computational thermochemistry, since the model is still only of moderate cost, albeit markedly more costly than, e.g., the CCSDT(Q) and ΛCCSDT(Q) models.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

On the accuracy of Hipparcos using binary stars as a calibration tool

Stellar binary systems, specifically those that present the most accurate available orbital elements, are a reliable tool to test the accuracy of astrometric observations. We selected all 35 binaries with these characteristics. Our objective is to provide standard uncertainties for the positions and parallaxes measured by Hipparcos relative to this trustworthy set, as well as to check supposed correlations between several parameters (measurement residuals, positions, magnitudes, and parallaxes). In addition, using the high-confidence subset of visual–spectroscopic binaries, we implemented a validation test of the Hipparcos trigonometric parallaxes of binary systems that allowed the evaluation of their reliability. Standard and non-standard statistical analysis techniques were applied in order to achieve well-founded conclusions. In particular, errors-in-variables models such as the total least-squares method were used to validate Hipparcos parallaxes by comparison with those obtained directly from the orbital elements. Previously, we executed Thompson's τ technique in order to detect suspected outliers in the data. Furthermore, several statistical hypothesis tests were carried out to verify if our results were statistically significant. A statistically significant trend indicating larger Hipparcos angular separations with respect to the reference values in 5.2 ± 1.4 mas was found at the 10{sup −8} significance level. Uncertainties in the polar coordinates θ and ρ of 1.°8 and 6.3 mas, respectively, were estimated for the Hipparcos observations of binary systems. We also verified that the parallaxes of binary systems measured in this mission are absolutely compatible with the set of orbital parallaxes obtained from the most accurate orbits at least at the 95% confidence level. This methodology allows us to better estimate the accuracy of Hipparcos observations of binary systems. Indeed, further application to the data collected by Gaia should yield a standard procedure to compare both data sets.

79 ASTRONOMY AND ASTROPHYSICS↗

The effect of inhomogeneities on the distance to the last scattering surface and the accuracy of the CMB analysis

The standard analysis of the CMB data assumes that the distance to the last scattering surface can be calculated using the distance-redshift relation as in the Friedmann model. However, in the inhomogeneous universe, even if (δρ) = 0, the distance relation is not the same as in the unperturbed universe. This can be of serious consequences as a change of distance affects the mapping of CMB temperature fluctuations into the angular power spectrum C{sub l}. In addition, if the change of distance is relatively uniform no new temperature fluctuations are generated. It is therefore a different effect than the lensing or ISW effects which introduce additional CMB anisotropies. This paper shows that the accuracy of the CMB analysis can be impaired by the accuracy of calculation of the distance within the cosmological models. Since this effect has not been fully explored before, to test how the inhomogeneities affect the distance-redshift relation, several methods are examined: the Dyer-Roeder relation, lensing approximation, and non-linear Swiss-Cheese model. In all cases, the distance to the last scattering surface is different than when homogeneity is assumed. The difference can be as low as 1% and as high as 80%. An usual change of the distance is around 20–30%. Since the distance to the last scattering surface is set by the position of the CMB peaks, in order to have a good fit, the distance needs to be adjusted. After correcting the distance, the cosmological parameters change. Therefore, a not properly estimated distance to the last scattering surface can be a major source of systematics. This paper shows that if inhomogeneities are taken into account when calculating the distance then models with positive spatial curvature and with Ω{sub Λ} ∼ 0.8−0.9 are preferred.

79 ASTRONOMY AND ASTROPHYSICS↗

Matter power spectrum and the challenge of percent accuracy

Future galaxy surveys require one percent precision in the theoretical knowledge of the power spectrum over a large range including very nonlinear scales. While this level of accuracy is easily obtained in the linear regime with perturbation theory, it represents a serious challenge for small scales where numerical simulations are required. In this paper we quantify the precision of present-day N -body methods, identifying main potential error sources from the set-up of initial conditions to the measurement of the final power spectrum. We directly compare three widely used N -body codes, Ramses, Pkdgrav3, and Gadget3 which represent three main discretisation techniques: the particle-mesh method, the tree method, and a hybrid combination of the two. For standard run parameters, the codes agree to within one percent at k ≤1 h Mpc{sup −1} and to within three percent at k ≤10 h Mpc{sup −1}. We also consider the bispectrum and show that the reduced bispectra agree at the sub-percent level for k ≤ 2 h Mpc{sup −1}. In a second step, we quantify potential errors due to initial conditions, box size, and resolution using an extended suite of simulations performed with our fastest code Pkdgrav3. We demonstrate that the simulation box size should not be smaller than L =0.5 h {sup −1}Gpc to avoid systematic finite-volume effects (while much larger boxes are required to beat down the statistical sample variance). Furthermore, a maximum particle mass of M {sub p}=10{sup 9} h {sup −1}M{sub ⊙} is required to conservatively obtain one percent precision of the matter power spectrum. As a consequence, numerical simulations covering large survey volumes of upcoming missions such as DES, LSST, and Euclid will need more than a trillion particles to reproduce clustering properties at the targeted accuracy.

79 ASTRONOMY AND ASTROPHYSICS↗

Accuracy versus run time in an adiabatic quantum search

Adiabatic quantum algorithms are characterized by their run time and accuracy. The relation between the two is essential for quantifying adiabatic algorithmic performance yet is often poorly understood. We study the dynamics of a continuous time, adiabatic quantum search algorithm and find rigorous results relating the accuracy and the run time. Proceeding with estimates, we show that under fairly general circumstances the adiabatic algorithmic error exhibits a behavior with two discernible regimes: The error decreases exponentially for short times and then decreases polynomially for longer times. We show that the well-known quadratic speedup over classical search is associated only with the exponential error regime. We illustrate the results through examples of evolution paths derived by minimization of the adiabatic error. We also discuss specific strategies for controlling the adiabatic error and run time.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Improved time-domain accuracy standards for model gravitational waveforms

Model gravitational waveforms must be accurate enough to be useful for detection of signals and measurement of their parameters, so appropriate accuracy standards are needed. Yet these standards should not be unnecessarily restrictive, making them impractical for the numerical and analytical modelers to meet. The work of Lindblom, Owen, and Brown [Phys. Rev. D 78, 124020 (2008)] is extended by deriving new waveform accuracy standards which are significantly less restrictive while still ensuring the quality needed for gravitational-wave data analysis. These new standards are formulated as bounds on certain norms of the time-domain waveform errors, which makes it possible to enforce them in situations where frequency-domain errors may be difficult or impossible to estimate reliably. These standards are less restrictive by about a factor of 20 than the previously published time-domain standards for detection, and up to a factor of 60 for measurement. These new standards should therefore be much easier to use effectively.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Postprocessing for Improved Accuracy and Resolution of Spread Spectrum Time-Domain Reflectometry

Reflectometry, which is commonly used for locating faults on electrical wires, produces sampled time domain signatures with peaks that are often missed due to this sampling. Resultant errors in these sampled peaks translate to errors in calculating the impedance and location of the fault. Typical signal processing methods to improve the accuracy of these sampled peaks have complexity on the order of O(N 2 ). For embedded fault location applications, algorithms with lower complexity are desired. In this article, we introduce three algorithms for improving the accuracy of the peak with a complexity of O(N). Finally, we evaluate these algorithms on the practical case of calculating the velocity of propagation and the characteristic impedance of a photovoltaic (PV) cable using spread spectrum time-domain reflectometry.

47 OTHER INSTRUMENTATION↗

Shake loss intensities in x-ray photoelectron spectroscopy: Theory, experiment, and atomic composition accuracy for MgO and related compounds

The relative intensities of XPS core levels, scaled by their photoionization cross sections, are regularly used to determine sample atomic composition. Cross sections, however, give the intensity to all possible final states for the core ionizations, not just to the main peak. This includes all intrinsic satellite structure (shake states and, for open shell systems, the different ionic multiplets). In practice, for solids, this is usually experimentally impossible to determine accurately because such a satellite structure sits on the inelastically scattered electron background and cannot be easily separated. Therefore, usually, only the intensity of the main peak is used. This limits the ultimate possible accuracy of XPS composition determination. The purpose of the present paper is to examine the contributions that a theoretical analysis of losses of intensity can make to improve quantitation. For an MgO single crystal, we show that the correct stoichiometry of 1:1 can be recovered using the theoretical analysis of the experimental MgO peak ratio intensities. For materials with a sufficient bandgap for the XPS main peaks to be separated from the scattered background, the intensity of main peaks can often be accurately determined. Thus, if one uses theory to calculate that fraction of the total intensity lost from a main peak into all its satellite structure, the intensity of just main peaks could then be used to more accurately determine relative atom % composition. This work tests this approach using a single crystal MgO (50% Mg, 50% O) standard. Ab initio electronic structure theory of representative MgO clusters is used to determine Hartree–Fock wave functions for the ground state and final ionized states corresponding to the main Mg 2p and O1s XPS peaks of the oxide. The sudden approximation, SA, is used to determine the fractional losses from these main peaks to shake satellites, which is found to be greater for O1s than Mg2p. This results in predicted “apparent composition” for stoichiometric MgO of 55.2% Mg, 44.8% O instead of the true 50% Mg, 50% O. Equivalent theory for CaO results in a predicted apparent Ca value of 53.4%. Experimentally, using Mg2s or 2p intensity ratio to O1s, we find values between 52.2% and 56.0% Mg using two crystals and four different instrument electron pass energies. The average value of the measurements is 54.5% Mg when corrected for the presence of an adventitious carbon overlayer and slight surface hydroxide. Though this agreement with theory may be somewhat fortuitous, given the potential experimental errors, which are fully discussed, it is similar to that in our earlier study on LiF. We also present preliminary experimental data on Mg(OH) 2 and MgSO 4 , which show a similar trend of apparently higher than 50% Mg, but we have no theory values. We are not yet able to experimentally test for validation of the difference between apparent composition for MgO (55.2% Mg) and CaO (53.4% Ca), owing to significant carbonate formation at the surface of the single crystal CaO. Here, an important conclusion is that the theoretical determination of shake losses, obtained with ab initio wavefunctions and the SA, is likely to be a useful way to calibrate the accuracy and reliability of compositions obtained from XPS intensities and merits further study.

47 OTHER INSTRUMENTATION↗

Examination of geometric and dosimetric accuracies of gated step-and-shoot intensity modulated radiation therapy

Due to the complicated technical nature of gated radiation therapy, electronic and mechanical limitations may affect the precision of delivery. The purpose of this study is to investigate the geometric and dosimetric accuracies of gated step-and-shoot intensity modulated radiation treatments (SS-IMRT). Unique segmental MLC plans are designed, which allow quantitative testing of the gating process. Both ungated and gated deliveries are investigated for different dose sizes, dose rates, and gating window times using a commercial treatment system (Varian Trilogy) together with a respiratory gating system [Varian Real-Time Position Management system]. Radiographic film measurements are used to study the geometric accuracy, where it is found that with both ungated and gated SS-IMRT deliveries the MLC leaf divergence away from planned is less than or equal to the MLC specified leaf tolerance value for all leafs (leaf tolerance being settable from 0.5-5 mm). Nevertheless, due to the MLC controller design, failure to define a specific leaf tolerance value suitable to the SS-IMRT plan can lead to undesired geometric effects, such as leaf motion of up to the maximum 5 mm leaf tolerance value occurring after the beam is turned on. In this case, gating may be advantageous over the ungated case, as it allows more time for the MLC to reach the intended leaf configuration. The dosimetric precision of gated SS-IMRT is investigated using ionization chamber methods. Compared with the ungated case, it is found that gating generally leads to increased dosimetric errors due to the interruption of the 'overshoot phenomena.' With gating the average timing deviation for intermediate segments is found to be 27 ms, compared to 18 ms for the ungated case. For a plan delivered at 600 MU/min this would correspond to an average segment dose error of {approx}0.27 MU and {approx}0.18 MU for gated and ungated deliveries, respectively. The maximum dosimetric errors for individual intermediate segments are found to deviate by up to {approx}0.64 MU from their planned value when delivered at 600 MU/min using gating, this compares to only {approx}0.32 MU for the ungated case.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Anniversary Paper: Role of medical physicists and the AAPM in improving geometric aspects of treatment accuracy and precision

The last 50 years have seen great advances in the accuracy of external beam radiation therapy. Geometrical uncertainties have been reduced from a centimeter or more in presimulation, skin-mark guided days to 1-2 mm in today's image-guided radiation therapy treatments. Medical physicists, with the support and guidance of the American Association of Physicists in Medicine (AAPM), have been, and continue to be, at the forefront of research, development and clinical implementation in this area. This article reviews some of the major contributions of physicists to the improvement of treatment accuracy and precision, and speculates as to what the future may bring.

62 RADIOLOGY AND NUCLEAR MEDICINE↗