Search NASA⌕ Search

SEARCH · Search NASA

Results for “Advanced Photon Source”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

High P-T phase transitions and P-V-T equation of state of hafnium

We measured the volume of hafnium at several pressures up to 67 GPa and at temperatures between 300 to 780 K using a resistively heated diamond anvil cell with synchrotron x-ray diffraction at the Advanced Photon Source. The measured data allows us to determine the P-V-T equation of state of hafnium. The previously described [Xia et al., Phys. Rev. B 42, 6736-6738 (1990)] phase transition from hcp ({alpha}) to simple hexagonal ({omega}) phase at 38 GPa at room temperature was not observed even up to 51 GPa. The {omega} phase was only observed at elevated temperatures. Our measurements have also improved the experimental constraint on the high P-T phase boundary between the {omega} phase and high pressure bcc ({beta}) phase of hafnium. Isothermal room temperature bulk modulus and its pressure derivative for the {alpha}-phase of hafnium were measured to be B{sub 0} = 112.9{+-}0.5 GPa and B{sub 0}'=3.29{+-}0.05, respectively. P-V-T data for the {alpha}-phase of hafnium was used to obtain a fit to a thermodynamic P-V-T equation of state based on model by Brosh et al. [CALPHAD 31, 173-185 (2007)].

Hrubiak, Rostislav↗

Structural evolution of detonation carbon in composition B by X-ray scattering

Products evolved during the detonation of high explosives are primarily a collection of molecular gases and solid carbon condensates. Electron microscopy studies have revealed that detonation carbon (soot) can contain a variety of unique carbon particles possessing novel morphologies, such as carbon onions and ribbons. Despite these observations very little is known about the conditions that leads to the production of these novel carbon nanoparticles. A fuller understanding on conditions that generate such nanoparticles would greatly benefit from time-resolved studies that probe particle formation and evolution through and beyond the chemical reaction zone. Herein, we report initial results employing time-resolved X-ray scattering (TRSAXS) measurements to monitor nanosecond time-scale carbon products formed from detonating Composition B (60% TNT, 40% RDX). These studies were performed at the Dynamic Compression Sector (DCS, Sector 35) at the Advanced Photon Source (Argonne National Laboratory). Lastly, analysis of the collected scattering patterns reveals the presence of fractal multi-layered carbon condensates.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

i RadMat: A thermo-mechanical testing system for in situ high-energy X-ray characterization of radioactive specimens

Here, we present an in situ Rad iated Mat erials (iRadMat) experimental module designed to interface with a servo-hydraulic load frame for X-ray measurements at beamline 1-ID at the Advanced Photon Source. This new capability allows in situ studies of radioactive specimens subject to thermo-mechanical loading using a suite of high-energy X-ray scattering and imaging techniques. The iRadMat is a radiation-shielded vacuum heating system with the sample rotation-under-load capability. We describe the design features and performances of the iRadMat and present a dataset from a 300 °C uniaxial tensile test of a neutron-irradiated pure Fe specimen to demonstrate its capabilities.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

DIASCoPE: Directly integrated acoustic system combined with pressure experiments—A new method for fast acoustic velocity measurements at high pressure

A novel experimental system to measure elastic wave velocities in samples in situ under extreme conditions of pressure and temperature in a multi-anvil apparatus has been installed at Beamline 6-BM-B of the Advanced Photon Source at Argonne National Laboratory. This system allows for measurement of acoustic velocities via ultrasonic interferometry, and makes use of the synchrotron beam to measure sample densities via X-ray diffraction and sample lengths using X-radiographic imaging. This system is fully integrated into the automated software controls of the beamline and is capable of collecting robust data on elastic wave travel times in less than 1 s, which is an improvement of more than one to two orders of magnitude over existing systems. Moreover, this fast data collection time has been shown to have no effect on the obtained travel time results. This allows for more careful study of time-dependent phenomena with tighter snapshots in time of processes that would otherwise be lost or averaged out in other acoustic measurement systems.

Whitaker, Matthew L.↗

Heavy ion linear accelerator for radiation damage studies of materials

A new eXtreme MATerial (XMAT) research facility is being proposed at Argonne National Laboratory to enable rapid in situ mesoscale bulk analysis of ion radiation damage in advanced materials and nuclear fuels. This facility combines a new heavy-ion accelerator with the existing high-energy X-ray analysis capability of the Argonne Advanced Photon Source. The heavy-ion accelerator and target complex will enable experimenters to emulate the environment of a nuclear reactor making possible the study of fission fragment damage in materials. Material scientists will be able to use the measured material parameters to validate computer simulation codes and extrapolate the response of the material in a nuclear reactor environment. Utilizing a new heavy-ion accelerator will provide the appropriate energies and intensities to study these effects with beam intensities which allow experiments to run over hours or days instead of years. The XMAT facility will use a CW heavy-ion accelerator capable of providing beams of any stable isotope with adjustable energy up to 1.2 MeV/u for 238 U 50+ and 1.7 MeV for protons. This energy is crucial to the design since it well mimics fission fragments that provide the major portion of the damage in nuclear fuels. The energy also allows damage to be created far from the surface of the material allowing bulk radiation damage effects to be investigated. Furthermore, the XMAT ion linac includes an electron cyclotron resonance ion source, a normal-conducting radio-frequency quadrupole and four normal-conducting multi-gap quarter-wave resonators operating at 60.625 MHz. This paper presents the 3D multi-physics design and analysis of the accelerating structures and beam dynamics studies of the linac.

47 OTHER INSTRUMENTATION↗

Fabrication and efficiency measurement of a Mo/C/Si/C three material system multilayer Laue lens

In this letter we report on the manufacturing of a multilayer Laue lens (MLL) consisting of a multilayer stack with three materials: molybdenum and silicon as absorber and spacer layer, respectively, and carbon as transition layers. The design has four layers per period: Mo/C/Si/C. It yields 6000 zones, and provides an aperture of 50 μm. This allows the MLL structure to accept a large portion of the coherent part of the beam and achieving a small spot size. The MLL deposition was made by magnetron sputtering at the Fraunhofer IWS, the sectioning was done by laser cutting and subsequent focused ion beam milling to a thickness that provides a good efficiency for a photon energy of 12 keV. The diffraction efficiency as a function of the tilting angle has been measured at beamline 1-BM of the Advanced Photon Source. An efficiency of almost 40% has been achieved. This shows that the material system performs well compared to MLLs made of two-materials and that it is in an excellent agreement with the numerically calculated efficiency for a comparable molybdenum/silicon bilayer system lens. Here, we conclude that the three material system offers high efficiencies and is advantageous for stress reduction in MLLs.

36 MATERIALS SCIENCE↗

Correlation of the fragility of metallic liquids with the high temperature structure, volume, and cohesive energy

In this work, the thermal expansion coefficients, structure factors, and viscosities of twenty-five equilibrium and supercooled metallic liquids have been measured using an electrostatic levitation (ESL) facility. The structure factor was measured at the Advanced Photon Source, Argonne, using the ESL. A clear connection between liquid fragility and structural and volumetric changes at high temperatures is established; the observed changes are larger for the more fragile liquids. It is also demonstrated that the fragility of metallic liquids is determined to a large extent by the cohesive energy and is, therefore, predictable. These results are expected to provide useful guidance in the future design of metallic glasses.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A compact membrane-driven diamond anvil cell and cryostat system for nuclear resonant scattering at high pressure and low temperature

In order to study the vibrational and thermal dynamic properties of materials using the nuclear resonant inelastic X-ray scattering (NRIXS) and the hyperfine interactions and magnetic properties using the synchrotron Mössbauer spectroscopy (SMS) at simultaneously high pressure (multi-Mbar) and low temperature (T< 10 K), a new miniature panoramic diamond anvil cell (mini-pDAC) as well as a special gas membrane driven mechanism have been developed and implemented at 3ID, Advanced Photon Source. The gas membrane system allows in situ pressure tuning of the mini- pDAC at low temperature. The mini-pDAC fits into a specially designed compact liquid helium flow cryostat system to achieve low temperature, where liquid helium flows through the holder of the mini-pDAC to cool the sample more efficiently. The sample temperature as low as 9 K has been achieved. Through the membrane, the sample pressure as high as 1.4 Mbar has been generated from this mini-pDAC. The instrument has been routinely used at 3ID for NRIXS and SMS studies. In this paper, technical details of the mini-pDAC, membrane engaging mechanism and the cryostat system are described, and some experimental results are discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of a hybrid molecular beam epitaxy deposition system for in situ surface x-ray studies

A portable metalorganic gas delivery system designed and constructed to interface with an existing molecular beam epitaxy chamber at beamline 33-ID-E of the Advanced Photon Source is described. This system offers the ability to perform in situ X-ray measurements of complex oxide growth via hybrid molecular beam epitaxy. The performance of the hybrid molecular beam epitaxy system while delivering metalorganic source materials is described. In conclusion, the high-energy X-ray scattering capabilities of the hybrid molecular beam epitaxy system are demonstrated both on oxide films grown solely from the metalorganic source and ABO 3 oxide perovskites containing elements from both the metalorganic source and a traditional effusion cell.

36 MATERIALS SCIENCE↗

Demonstration of a chamber for strain mapping of steel specimens under mechanical load in a hydrogen environment by synchrotron radiation

Here, we demonstrate a hydrogen gas chamber suitable for lattice strain measurements and capturing radiographs of a steel specimen under a mechanical load using high energy synchrotron x-rays. The chamber is suitable for static and cyclic mechanical loading. Experiments were conducted at the 1-ID-E end station of the Advanced Photon Source, Argonne National Laboratory. Diffraction patterns show a high signal-to-noise ratio suitable for lattice strain measurements for the specimen and with minimal scattering and overlap from the gas chamber manufactured from aluminum. In situ radiographs of a specimen in the hydrogen chamber show the ability to track a growing crack and to map the lattice strain around the crack with high spatial and strain resolution.

47 OTHER INSTRUMENTATION↗

A CO 2 laser heating system for in situ high pressure-temperature experiments at HPCAT

We present a CO 2 laser heating setup for synchrotron x-ray diffraction inside a diamond anvil cell, situated at HPCAT (Sector 16, Advanced Photon Source, Argonne National Lab, Illinois, USA), which is modular and portable between the HPCAT experiment hutches. Specifically, the system allows direct laser heating of wide bandgap insulating materials to thousands of degrees at static high pressures up to the Mbar regime. Alignment of the focused CO 2 laser spot is performed using a mid-infrared microscope, which addressed past difficulties with aligning the invisible radiation. The implementation of the mid-infrared microscope alongside a mirror pinhole spatial filter system allows precise alignment of the heating laser spot and optical pyrometry measurement location to the x-ray probe. A comparatively large heating spot (~50 μ m) relative to the x-ray beam (<10 μ m) reduces the risk of temperature gradients across the probed area. Each component of the heating system and its diagnostics have been designed with portability in mind and compatibility with the various experimental hutches at the HPCAT beamlines. We present measurements on ZrO 2 at 5.5 GPa which demonstrate the improved room-temperature diffraction data quality afforded by annealing with the CO 2 laser. We also present in situ measurements at 5.5 GPa up to 2800 K in which we do not observe the postulated fluorite ZrO 2 structure, in agreement with recent findings.

47 OTHER INSTRUMENTATION↗

Towards in-situ high precision local material velocity measurements in lattice materials under dynamic compression

The study of dynamic compression of materials requires high precision spatial and temporal resolution to infer the material state at any given time. In ultra-fast imaging experiments such as those performed at the Dynamic Compression Sector at the Advanced Photon Source, the current CCD frame rate is less than the X-ray pulse rate necessitating that 4 CCDs be used to image a single scintillator screen to obtain the same projection of transmitted or diffracted beam at time intervals synchronized with the X-ray beam. The use of multiple-camera setups is often employed for a variety of reasons including enhancing the temporal resolution through interleaving frames or increasing the number of viewpoints, for example. Physical corrections are made to have each CCD approximately viewing the same field of view, however we present corrections that can be made after the data collection to further refine and be able to compare movements and changes in the sample between independent CCDs. These software corrections enable higher precision and higher fidelity comparison of position changes due to sample deformation. Furthermore, we present a method to correct images (or frames) as a demonstration toward high fidelity displacement measurements in these types of ultra-fast multi-camera setup experiments.

36 MATERIALS SCIENCE↗

On evaluating x-ray imaging crystals with synchrotron radiation

Bent crystals are central to 1-D resolved x-ray spectroscopy and two-dimensional x-ray imaging of plasmas. Nominally identical crystals may differ in their performance with x-rays even though their visible-light images are close to identical. The detailed information needed to understand those differences, viz., the crystal’s local diffraction properties over the area that contributes to the image, is averaged out in the imaging tests that ideally precede the actual crystal’s use. Here the local diffraction of spherically bent crystals made from quartz is examined in the x-ray topography setup at the x-ray optics testing beamline 1-BM at the Advanced Photon Source, with radiation obtained from a flat quartz conditioning crystal made for the purpose.

Pereira, N. R.↗

Fly scan apparatus for high pressure research using diamond anvil cells

In this paper, the hardware and software used to execute fly scans at Sector 16 of the Advanced Photon Source is described. The system design and capabilities address dimensions and time scales relevant to samples in high pressure diamond anvil cells. The time required for routine sample positioning and centering is significantly reduced and, more importantly, the time savings associated with fly scanning makes it feasible for users to routinely generate two-dimensional x-ray transmission and x-ray diffraction maps. Consequently, this facilitates an important shift in high pressure research as experimentalists embrace the study of heterogeneous and minute sample volumes in the diamond anvil cell.

47 OTHER INSTRUMENTATION↗

Multimode scanning X-ray diffraction microscopy for diamond anvil cell experiments

We have designed and implemented a new experimental system for fast mapping of crystal structures and other structural features of materials under high pressure at the High Pressure Collaborative Access Team, Sector 16 of the Advanced Photon Source. The system utilizes scanning X-ray diffraction microscopy (SXDM) and is optimized for use with diamond anvil cell devices. In SXDM, the X-ray diffraction (XRD) is collected in a forward scattering geometry from points on a two-dimensional grid by fly-scanning the sample with respect to a micro-focused X-ray beam. The recording of XRD is made during the continuous motion of the sample using a fast (millisecond) X-ray area detector in synchrony with the sample positioners, resulting in a highly efficient data collection for SXDM. A new computer program, X-ray Diffractive Imaging (XDI), has been developed with the SXDM system. The XDI program provides a graphical interface for constructing and displaying the SXDM images in several modes: (1) phase mapping based on structural information, (2) pressure visualization based on the equation of state, (3) microstructural features mapping based on peak shape parameters, and (4) grain size and preferred-orientation based on peak shape parameters. The XDI is a standalone program and can be generally used for displaying SXDM images. Two examples of iron and zirconium samples under high pressure are presented to demonstrate the applications of SXDM. Published under license by AIP Publishing.

47 OTHER INSTRUMENTATION↗

Precision Flexure Stages Design for a Compact Multilayer Laue Lens Test Bed for Hard X-ray Nanofocusing

Both the Advanced Photon Source (APS) at Argonne National Laboratory (ANL) and the Beijing Synchrotron Radiation Facility (BSRF) at Institute of High Energy Physics (IHEP) have a keen interest in the development of a compact Multilayer Laue Lens (MLL) test bed for hard x-ray nanofocusing. Recently, collaboration between ANL and IHEP, as a part of the Argonne Strategic Partnership Project (SPP) 85J05, has produced designs of precision flexure stages for a compact MLL test bed for hard x-ray nanofocusing using commercial flexural pivots and Argonne developed laminar nanopositioning flexures. Two sets of the new flexure stages will be built with the new designs, one for R&D activities at the BSRF for the new planned 6 GeV high energy photon source (HEPS) and one for upgrade of the existing MLL test bed at the APS x-ray optics test beamline. Mechanical design and preliminary test for the MLL test bed flexure stages for Argonne SPP project 85J05 are presented in this paper.

nanopositioning flexure stage↗

Optomechanical Design of Compact Laminar Flexure Bending Mechanism for Elliptically Bent Hard X-ray Mirrors

As a part of the Argonne Strategic Partnership Project (SPP) 85E77, collaboration between Argonne National Laboratory (ANL) and Shanghai Institute of Applied Physics (SINAP), has produced designs for a precision compact flexure bending mechanism to provide elliptically shaped 90-mm and 160-mm long hard x-ray mirrors. The design utilizes Argonne's laminar nanopositioning flexure technique. The flexure mirror bending mechanism will be incorporated into the beamline upgrade project at the Shanghai Synchrotron Radiation Facility (SSRF). Additionally, an Argonne Laboratory-Directed Research and Development (LDRD) project at the Advanced Photon Source (APS) has adopted a modified optomechanical design of the precision compact mirror benders for 300-mm-long hard x-ray mirrors with integrated profile monitoring and feedback, which are described in this paper. The mirror benders are designed with configurations for open-loop or closed-loop controls. Capacitive sensors can be applied to the mirror benders to ensure positioning reproducibility. Design specifications as well as finite element analyses results of the compact mirror benders for hard x-ray mirrors with trapezoid and rectangular shapes are discussed in this paper.

X-ray optics, nanopositioning flexure stage↗

Mechanical Design of a UHV Non-magnetic Kappa Diffractometer

A UHV non-magnetic kappa geometry diffractometer has been designed for the resonant soft X-ray scattering (RSXS) branch of the Intermediate Energy X-ray (IEX) beamline at the Advanced Photon Source (APS), Argonne National Laboratory. The kappa geometry allows for a large q-range and space for a sample environment (electric or magnetic fields). To avoid distorting the sample environment field, non-magnetic SmarAct, GmbH stages are used for the 4)-axis, X, Y, and Z linear stages. The ic and 0 axes are controlled by high-precision UHV compatible Physik Instrumente (PI) GmbH & Co. rotation stages. The design goal was to achieve a 50 gm sphere of confusion. To achieve this, iterative designs were developed using FEA and commercial stages were chosen that had minimal wobble, eccentricity, and flatness errors.

X-ray diffractometer↗