Search NASA⌕ Search

SEARCH · Search NASA

Results for “Analysis software”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

A New Workflow of X-ray CT Image Processing and Data Analysis of Structural Features in Rock Using Open-Source Software

X-ray computed tomography (CT) images of rock specimens often contain artifacts which must be corrected before scientific analyses are performed. Here, we present a new workflow of automated image processing to utilize poor-quality X-ray CT scan images. The workflow runs on the open-source image analysis software and efficiently separates desired features from low-contrast scanned images. The new workflow is a two-step technique using contrast enhancement and automated feature segmentation to generate noise-free binary images. The results of binary images using the proposed workflow and using a conventional thresholding technique are analyzed to show the quality of the proposed method. The paper also presents a workflow of estimating the structural geometries of features in two and three dimensions. The results of the structural feature analyses and computational time were compared between the open-source (ImageJ) and commercial image analysis software (Bruker Computed Tomography Analyzer). The commercial software was more computationally efficient, but the task-specific macros in open-source software enabled the user-desired automation in image processing and data extraction of desired structural features of comparable quality.

47 OTHER INSTRUMENTATION↗

SCA Tools - SCRM Value Add or Lossy Noise Machines

Software supply chain risk management (SCRM) depends upon accurate information regarding the software components that comprise any given software system. The collection of components included in a software package can be organized within a software bill of materials, or SBOM. SBOMs are ideally generated when the software components are put together, such as at compile time, but for many reasons that has not and is not always possible. For example, legacy or proprietary software packages often do not have SBOMs available to downstream consumers of that software. It’s not just end users that are affected, manufacturers themselves also must deal with this problem. To answer these questions, the market has seen the rise of several commercial software composition analysis (SCA) tools. These tools aim to peer into completed software systems, automatically identifying hidden software dependencies and looking up known vulnerabilities associated with those dependencies to enable end-users to enhance their cyber supply chain risk management processes. These tools are potentially a huge boon to end users of legacy and proprietary software – and a potential bane, depending on how accurate they are. This research asks that question – how accurate are currently available binary SCA tools – and provides answers to several other questions: What does it mean to be “accurate”? What limitations do the tools have in identifying common edge cases that take place in modern software development? Can they help you avoid a devastating supply chain attack, or is it all just noise? After researching SCA tools on the market, we identified three vendors that fit our use case and would provide analysis on compiled binaries. Using these tools, we submitted firmware for critical infrastructure devices for analysis and SBOM generation. The SBOM outputs were then cross referenced with SBOMs generated through manual analysis for comparison. In addition to the firmware samples, we also submitted edge case samples based off a popular open-source library that were specifically crafted to evaluate each tools’ ability to accurately identify components. These samples were customized to be consistent with modifications we have seen in modern software development as well as a couple that are representative of supply chain attacks.

97 MATHEMATICS AND COMPUTING↗

Digital X-ray Pipe Inspector Software

The Digital X-ray Pipe Inspector software requires a digital x-ray image of a pipe as input to the program, such as the image in Attachment A Figure 1. The image may be in a variety of software formats such as bitmap, jpeg, tiff, DICOM or DICONDE. The software allows the user to interactively select a region of interest from the image for analysis. This software is used to analyze digital x-ray images of pipes to evaluate loss of wall thickness. The software specifically provides tools to analyze the image in (a) the pipe walls, (b) between the pipe walls. Traditional software uses only the information at the pipe wall while this new software also evaluates the image between the pipewalls. This makes the inspection process faster, more thorough, more efficient, and reduces expensive reshots. Attachment A Figure 2 shows a region of interest (a green box) drawn by the user around an anomaly in the pipe wall. This area is automatically analyzed by the external pipe wall tool with the result shown in Attachment A Figure 3. The edges of the pipe wall are detected and highlighted in yellow and areas where the wall thickness in less the the minimum wall threshold are shown in red. These measurements are typically made manually in other software programs, which lead to errors and inconsistency because the location of the edges are estimated by the user. Attachment A Figure 4 shows a region of interest (a green box) drawn by the user between the pipe walls. As can be seen there are intensity anomalies that correspond to wall defects. However, this information is not used directly by other software programs. In order to fully investigate these anomalies, the pipe would be reinspected in a different orientation to attempt to obtain a view of the anomaly in the pipe wall rather than the interior of the pipe. The pipe may need to be x-rayed a number of times to obtain the correct orientation. This is very costly and time consuming. The new software can perform the analysis directly on the intensity information in the original image. Figures 5 through 9 in Attachment A show wall defects in red for various percents of wall thickness loss. For example, Figure 5 show defects (in red) where the wall thickness is 95% or less than the nominal wall thickness (or a 5% or greater wall thickness loss). Wall thicknesses can be given in absolute terms as well.

Gibbs, Kenneth M.↗

Interactive statistical decision tools (GiSdT): An open source software integration of decision analysis and stakeholder judgment for sustainable waste management, disposal and remediation - 15650

The vast majority of remediation and waste management decisions are made without quantitative consideration of economic and socio-political factors. They are made instead based on quantitative metrics of human health risk. Sustainable decisions need to be made based on all three 'pillars of sustainability' (economics, environment and social), and require understanding and characterization of the costs and values associated with each pillar. In addition, such decisions need to conform to regulatory or other legal requirements, which often constrains the decision space of interest. Although efforts are often made to include factors across all three pillars (for example, for decisions made under CERCLA), these efforts are usually qualitative, and hence difficult to defend. They lack technical defensibility, transparency and traceability. The purpose of GiSdT (Guided Interactive Statistical Decision Tools) is to provide a quantitative framework whereby all aspects of a decision problem, such as remediation and waste management decisions, can be addressed quantitatively, and hence, defensibly, transparently and traceably. Most decision-makers do not currently have access to useful or usable methods and approaches when are presented with choices that have significant impacts across all three pillars of sustainability. The goal of GiSdT is to provide that access by identifying or developing effective and user-friendly decision methods and approaches that empower decision-makers to explicitly and routinely incorporate all aspects of sustainability into their decision-making. To identify and develop these methods and approaches, GiSdT provides the tools needed for decision-makers and stakeholders to understand and characterize their knowledge of their current decision-making processes, and what methods and approaches they need to pro-actively and quantitatively address all aspects of sustainability in their decisions. GiSdT is an open source interactive framework program that provides the tools needed to address the relevant components of a sustainability-based decision problem, including describing the decision landscape, translating that landscape into goals and objectives, valuing the measurable attributes that describe each objective, identifying decision options and addressing the uncertainty in the attributes (e.g., human health risk, institutional controls) through appropriate probabilistic models. In addition to addressing these quantitative technical components, the GiSdT program is aimed at facilitating stakeholder involvement so that the perspectives, values and objectives are all relevant stakeholders are addressed explicitly in the decision making process. The technical underpinnings of our software program, called Guided Interactive Statistical Decision Tools (GiSdT), are described. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

PyApprox: A software package for sensitivity analysis, Bayesian inference, optimal experimental design, and multi-fidelity uncertainty quantification and surrogate modeling

PyApprox is a Python-based one-stop-shop for probabilistic analysis of numerical models such as those used in the earth, environmental and engineering sciences. Easy to use and extendable tools are provided for constructing surrogates, sensitivity analysis, Bayesian inference, experimental design, and forward uncertainty quantification. The algorithms implemented represent a wide range of methods for model analysis developed over the past two decades, including recent advances in multi-fidelity approaches that use multiple model discretizations and/or simplified physics to significantly reduce the computational cost of various types of analyses. An extensive set of Benchmarks from the literature is also provided to facilitate the easy comparison of new or existing algorithms for a wide range of model analyses. Here, this paper introduces PyApprox and its various features, and presents results demonstrating the utility of PyApprox on a benchmark problem modeling the advection of a tracer in groundwater.

54 ENVIRONMENTAL SCIENCES↗

Development of Automated Software Program for the Analysis of Alzheimer's Disease Scans: Evaluation of PET imaging with PBR-111 in HV and AD subjects

Study goal: A Phase 1 evaluation of the kinetics, clearance and cerebral distribution of one novel peripheral benzodiazepine receptors(PBR)positron emission tomography (PET) imaging agent, 18F-PBR-111 following intravenous administration in healthy volunteers and Alzheimer's disease (AD) patients. Short title: Evaluation of PET imaging with PBR-111 in HV and AD subjects Proof of Mechanism. Primary Objective: To evaluate the cerebral distribution of PBR-111 positron emission tomography (PET) for detection/exclusion of microglial activation in patients with Alzheimer's disease subjects compared to healthy volunteers. Secondary objectives: - To assess the dynamic uptake and washout of [18F]PBR-111, a potential imaging bio-marker for inflammatory changes in brain, using positron emission tomography in subjects with Alzheimer's disease (AD) and healthy volunteers (HV). - To perform blood metabolite characterization of [18F]PBR-111 in subjects with AD and HV to determine the nature of metabolites in assessment of [18F]-PBR-111 as a PET brain imaging agent. Name of radioactive drug substance: PBR-111 Dose(s): The applied PBR-111 radioactive dose will be up to 5.0 mCi, diluted in a maximum of 10 ml of saline. The radioligand will be administered as a slow intravenous bolus injection (i.e., 6 sec/ml) into a large vein (e.g., antecubital vein). Route of administration: Intravenous injection Duration of treatment: Single administration of a diagnostic agent Indication: PBR-111 positron emission tomography (PET) imaging has the potential to detect microglial activation. In the presence of PBR-111 uptake (representative of microglial activation), inflammation in the brain can be detected. Diagnosis and main criteria for inclusion: Study participants will be HVs and patients diagnosed with probable AD. HVs must be 18 years of age (at least four subjects 50 years of age) and have no evidence of cognitive impairment or other neurologic disease by medical history. The lack of cognitive impairment will also be based on a Clinical Dementia Rating (CDR) of 0. Patients with probable AD must be 50 years of age and must fulfill the National Institute of Neurological and Communicative Disorders and Stroke, Alzheimer's Disease and Related Disorders Association [NINCDS-ADRDA] criteria for probable AD. The CDR score must be 1.0 and 2.0 and have a modified Hachinski of 4. All HVs and all patients with probable AD must be able to comply with all study procedures. Study design: This is a Phase 1, open-label, single-center, non-randomized single dose study to assess the kinetics, clearance and cerebral distribution of PBR-111 PET imaging in detecting microglial activation in the brain in patients with probable AD compared to HVs. All aspects related to image acquisition, processing, and visual as well as quantitative evaluation will be developed, optimized, and validated (where required). Each subject will be required to visit the study center during the screening phase and on the PBR-111 PET imaging day (baseline). A telephone follow-up visit will be performed 7 days (± 3 days) after PBR-111 PET administration. At the screening visit, each subject (or caregiver in the case of AD subjects) will be asked to provide written informed consent or assent. During the screening phase (maximum duration of 60 days) subject medical, neurological, and surgical history, clinical assessments, and a neuro-psychiatric evaluation will be performed on all eligible subjects. Subjects will be allowed to leave the center after all evaluations have been completed. During this period an MRI of the brain will be performed during the screening period. If an MRI of the brain has been performed within six months of the imaging visit using the methods described in the protocol, and there has been no medically significant events in the interim, the previous MRI may be used. During the PBR-111 PET imaging day, all subjects will receive a single intravenous injection of PBR-111 and scanning will be performed over a 3.5 hour period. Each subject will have a telephone follow-up 7 days (± 3 days) thereafter to assess for adverse events. Methodology: - Assessments to provide clinical characterization of the AD subjects will be performed. - After administration of PBR-111, images will be generated with state-of-the-art PET imaging. Images will be assessed quantitatively for the presence of microglial activation by a nuclear physician blinded to clinical data. - Total radioactivity and estimation of the fraction of radioactivity associated to the un-metabolized tracer will be determined. In addition, the metabolite patterns of PBR-111 are determined in venous plasma and arterial samples based on high-performance liquid chromatography (HPLC) analyses. - Arterial sampling will be acquired in the initial two AD and two HV subjects and modeling will be assessed to determine if additional arterial sampling is necessary.

97 MATHEMATICS AND COMPUTING↗

Software tool for the analysis and visualization of whole genome alignments

GenomeVISTA is a tool which performs and displays pairwise and multiple whole genome DNA alignments. The tools provides a graphical user interface by which users can navigate alignments and multiple levels of resolution and get imformation about individual aligned regions. Users can load their own sequences into GenomeVISTA or view pre-computed alignments for genomes in the VISTA database.

Source record↗

Optimisation of the Search for CP-symmetry Violation at the Deep Underground Neutrino Experiment

The Deep Underground Neutrino Experiment (DUNE) is a next-generation long baseline experiment, which will be situated in South Dakota. Its detectors will utilise liquid-argon time projection chamber technology, which is able to capture neutrino interactions with an incredible spatial and calorimetric resolution. With what will become the world’s most intense neutrino beam, a highly capable near detector, and four (10kt fducial mass) far detector modules, DUNE will be able to achieve an ambitious physics programme. Most notably, DUNE will determine whether charge-parity symmetry is broken in neutrino oscillations - a finding that would have significant implications for the understanding of the matter-antimatter asymmetry in our Universe.This thesis presents the optimisation of a CP-violation analysis at DUNE using thePandora pattern-recognition software. The analysis assumes a 3.5 year exposure (1.36 × 1023 protons on target) to a neutrino and an antineutrino beam (7 year total). Only the predicted data of the far detector modules is used; near detector samples are not included. The initial sensitivity to CP-violation is found to be 3.8σ+0.9σ−1.1σ in an estimate that includes oscillation parameter uncertainties, systematic uncertainties and statistical fluctuations, and assumes a normal-ordering of the neutrino mass hierarchy. The performance of the Pandora event reconstruction is linked to that of the analysis, which is found to be limited by the reconstruction of the initial track-like region of electrons and photons. The ShowerRefinement algorithm is developed in response to this and its implementation into the analysis workflow results in an improved sensitivity to CP-violation of 4.6σ+0.9σ−1.0σ. With a perfected neutrino interaction vertex placement, this is further increased to 5.1σ+1.0σ−1.1σ.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

GADRAS-DRF Enhancements for Safeguards – Custom Peak Fitting to Enhance Model Fitting and Isotopics

One major software update was accomplished within the Gamma Detector Response and Analysis Software-Detector Response Function (GADRAS-DRF) package. This update allows users to adjust individual peak fits for use in subsequent analysis processes within GADRAS-DRF. A graphical user interface (GUI) was implemented so users can see the effect of their fit adjustments on the spectrum. This new feature will enhance the capability of the previously funded auto-enrichment and peak-based 1D model fit feature that was implemented in FY23 (Fiscal Year). Isotopic analysis was performed using M400 data obtained from uranium standards and the isotopic assessment is given with and without manual peak adjustments.

07 ISOTOPE AND RADIATION SOURCES↗

Quantitative Risk Analysis of High Safety Significant Safety-related Digital Instrumentation and Control Systems in Nuclear Power Plants using IRADIC Technology

This report documents the activities performed by Idaho National Laboratory (INL) during fiscal year (FY) 2021 for the U.S. Department of Energy (DOE) Light Water Reactor Sustainability (LWRS) Program, Risk Informed Systems Analysis (RISA) Pathway, digital instrumentation and control (DI&C) Risk Assessment project. In FY-2019, the RISA Pathway initiated a project to develop a risk assessment strategy for delivering a strong technical basis to support effective, licensable, and secure DI&C technologies for digital upgrades/designs. An integrated risk assessment technology for the DI&C systems (IRADIC technology) was proposed for this strategy, which aims to (1) provide a best-estimate risk-informed capability to quantitatively and accurately estimate the safety margin obtained from plant modernization, especially for the High Safety Significant Safety-related (HSSSR) DI&C systems, (2) develop an advanced risk assessment technology to support transition from analog to DI&C technologies for nuclear industry, (3) assure the long-term safety and reliability of vital HSSSR DI&C systems, (4) reduce uncertainty in costs and support integration of DI&C systems in the plant. To achieve these technical goals and deal with the expensive licensing justifications from regulatory insights, the IRADIC technology is instructive for nuclear vendors and utilities to effectively lower the costs associated with digital compliance and speed industry advances by: (1) defining an integrated risk-informed analysis process for DI&C upgrade, including hazard analysis, reliability analysis, and consequence analysis, (2) applying systematic and risk-informed tools to address common cause failures (CCFs) and quantify responding failure probabilities for DI&C technologies, particularly software CCFs, (3) evaluating the impact of digital failures at the individual level, system level, and plant level, (4) providing insights and suggestions on designs to manage the risks; thus, to support the development, licensing, and deployment of advanced DI&C technologies on nuclear power plant (NPPs). In this report, an approach for performing software CCF analysis, given limited data, is developed and demonstrated using a case study of a highly redundant digital reactor trip system. Consequence analysis is also performed based on different accident scenarios. Results indicate that plant modernization including the improvement of HSSSR DI&C systems will make great benefits to plant safety by providing more safety margins to accident management. In addition, a novel approach is proposed in this report for the quantification of software hazards when sufficient operational and testing data available. The method incorporates software development quality as well as strong analysis techniques to identify and link software defects to potential failure modes. The approach includes both semantic and test-based analysis to detect failures that can exist in different stages of the software development life cycle. This method is applied to an advanced human system interface relevant to reactor trip safety developed from the APR 1400 design.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗