Search NASA⌕ Search

SEARCH · Search NASA

Results for “BEAM LINES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

The New Fast Ignitor Oriented Target Area in the Vulcan Laser at the CLF

During the course of 2008 we have conducted an upgrade to one of the short pulse beam lines of the Vulcan laser and one of the target areas the Target Area West, at the Central Laser Facility . The aim of this upgrade was to provide to the plasma physics communities a facility capable to perform fast ignitor oriented experiments. The final specification of that target area will be to provide 500J at 10ps combined with 6 long pulse beams, with a total energy of 1.5 KJ, and another 100J 1ps pulse. Nevertheless, the target area was planned also to be flexible and it will be able to perform dual short pulse interaction, 100 J 1 ps per each beam. Some experiments have been already been conducted in this target area, with different configurations and laser requirements. We present here the state of this new target area and its capabilities.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A treatment planning study to assess the feasibility of laser-driven proton therapy using a compact gantry design

Purpose: Laser-driven proton acceleration is suggested as a cost- and space-efficient alternative for future radiation therapy centers, although the properties of these beams are fairly different compared to conventionally accelerated proton beams. The laser-driven proton beam is extremely pulsed containing a very high proton number within ultrashort bunches at low bunch repetition rates of few Hz and the energy spectrum of the protons per bunch is very broad. Moreover, these laser accelerated bunches are subject to shot-to-shot fluctuations. Therefore, the aim of this study was to investigate the feasibility of a compact gantry design for laser-driven proton therapy and to determine limitations to comply with. Methods: Based on a published gantry beam line design which can filter parabolic spectra from an exponentially decaying broad initial spectrum, a treatment planning study was performed on real patient data sets. All potential parabolic spectra were fed into a treatment planning system and numerous spot scanning proton plans were calculated. To investigate limitations in the fluence per bunch, the proton number of the initial spectrum and the beam width at patient entrance were varied. A scenario where only integer shots are delivered as well as an intensity modulation from shot to shot was studied. The resulting plans were evaluated depending on their dosimetric quality and in terms of required treatment time. In addition, the influence of random shot-to-shot fluctuations on the plan quality was analyzed. Results: The study showed that clinically relevant dose distributions can be produced with the system under investigation even with integer shots. For small target volumes receiving high doses per fraction, the initial proton number per bunch must remain between 1.4 × 10{sup 8} and 8.3 × 10{sup 9} to achieve acceptable delivery times as well as plan qualities. For larger target volumes and standard doses per fraction, the initial proton number is even more restricted to stay between 1.4 × 10{sup 9} and 2.9 × 10{sup 9}. The lowest delivery time that could be reached for such a case was 16 min for a 10 Hz system. When modulating the intensity from shot to shot, the delivery time can be reduced to 6 min for this scenario. Since the shot-to-shot fluctuations are of random nature, a compensation effect can be observed, especially for higher laser shot numbers. Therefore, a fluctuation of ±30% within the proton number does not translate into a dosimetric deviation of the same size. However, for plans with short delivery times these fluctuations cannot cancel out sufficiently, even for ±10% fluctuations. Conclusions: Under the analyzed terms, it is feasible to achieve clinically relevant dose distributions with laser-driven proton beams. However, to keep the delivery times of the proton plans comparable to conventional proton plans for typical target volumes, a device is required which can modulate the bunch intensity from shot to shot. From the laser acceleration point of view, the proton number per bunch must be kept under control as well as the reproducibility of the bunches.

60 APPLIED LIFE SCIENCES↗

Chromosome Aberrations in Human Epithelial Cells Exposed Los Alamos High-Energy Secondary Neutrons: M-BAND Analysis

High-energy secondary neutrons, produced by the interaction of galactic cosmic rays (GCR) with the atmosphere, spacecraft structure and planetary surfaces, contribute a significant fraction to the dose equivalent radiation measurement in crew members and passengers of commercial aviation travel as well as astronauts in space missions. The Los Alamos Nuclear Science Center (LANSCE) neutron facility's 30L beam line (4FP30L-A/ICE House) is known to generate neutrons that simulate the secondary neutron spectrum of the Earth's atmosphere at high altitude. The neutron spectrum is also similar to that measured onboard spacecrafts like the MIR and the International Space Station (ISS). To evaluate the biological damage, we exposed human epithelial cells in vitro to the LANSCE neutron beams with an entrance dose rate of 2.5 cGy/hr, and studied the induction of chromosome aberrations that were identified with multicolor-banding in situ hybridization (mBAND) technique. With this technique, individually painted chromosomal bands on one chromosome allowed the identification of inter-chromosomal aberrations (translocation to unpainted chromosomes) and intra-chromosomal aberrations (inversions and deletions within a single painted chromosome). Compared to our previous results with gamma-rays and 600 MeV/nucleon Fe ions of high dose rate at NSRL (NASA Space Radiation Laboratory at Brookhaven National Laboratory), the neutron data from the LANSCE experiments showed significantly higher frequency of chromosome aberrations. However, detailed analysis of the inversion type revealed that all of the three radiation types in the study induced a low incidence of simple inversions. Most of the inversions in gamma-ray irradiated samples were accompanied by other types of intrachromosomal aberrations but few inversions were accompanied by interchromosomal aberrations. In contrast, neutrons and Fe ions induced a significant fraction of inversions that involved complex rearrangements of both inter- and intrachromosome exchanges. The distribution of damage sites on chromosome 3 was also compared for different radiation types. The breakpoints were randomly localized on chromosome 3 with neutrons and Fe ions exposure, whereas non-random distribution with clustering breakpoints was observed with gamma-rays exposure. The specific fingerprint of neutron radiations on chromosomal aberrations will be discussed.

Hada, M.↗

Mechanical Design and Evaluation of the MP-11-Like Wire Scanner Prototype

A wire scanner (WS) is a linearly actuated diagnostic device that uses fiber wires (such as Tungsten or Silicon Carbide) to obtain the position and intensity profile of the proton beam at the Los Alamos Neutron Science Center (LANSCE) particle accelerator. LANSCE will be installing approximately 86 new WS in the near future as part of the LANSCE Risk Mitigation project. These 86 new WS include the replacement of many current WS and some newly added to the current linear accelerator and other beam lines. The reason for the replacement and addition of WS is that many of the existing actuators have parts that are no longer readily available and are difficult to find, thus making maintenance very difficult. One of the main goals is to construct the new WS with as many commercially-available-off-the-shelf components as possible. In addition, faster beam scans (both mechanically and in term of data acquisition) are desired for better operation of the accelerator. This document outlines the mechanical design of the new MP-11-like WS prototype and compares it to a previously built and tested SNS-like WS prototype.

42 ENGINEERING↗

Methods and Procedures for Shielding Analyses for the SNS

In order to provide radiologically safe Spallation Neutron Source operation, shielding analyses are performed according to Oak Ridge National Laboratory internal regulations and to comply with the Code of Federal Regulations. An overview of on-going shielding work for the accelerator facility and neutrons beam lines, methods, used for the analyses, and associated procedures and regulations is presented. Methods used to perform shielding analyses are described as well.

43 PARTICLE ACCELERATORS↗

Constants and Pseudo-Constants of Coupled Beam Motion in the PEP-II Rings

Constants of beam motion help as cross checks to analyze beam diagnostics and the modeling procedure. Pseudo-constants, like the betatron mismatch parameter or the coupling parameter det C, are constant till certain elements in the beam line change them. This can be used to visually find the non-desired changes, pinpointing errors compared with the model.

43 PARTICLE ACCELERATORS↗

Imposing strong correlated energy spread on relativistic bunches with transverse deflecting cavities

We demonstrate a novel scheme for imposing or removing large energy chirp on relativistic electron bunches. This method relies on the transverse-to-longitudinal mixing accomplished with a set of transverse deflecting cavities. The working principles of the new concept are explained using the first-order matrix formalism in the approximation of the linear single-particle dynamics. The scheme demonstrates versatility regarding the average beam energy and, hence, positioning along the accelerator beam line. The performance of the scheme is numerically investigated with the elegant particle-tracking code. It is shown that the associated nonlinear effects causing emittance deterioration for the extreme quantities of the total energy spread can be effectively compensated by optimization of the Twiss parameters while relying on the eigenemittance analysis. The impact of the longitudinal space charge effects on the beam dynamics in the proposed scheme is also investigated.

43 PARTICLE ACCELERATORS↗

Electron density profile measurements at a self-focusing ion beam with high current density and low energy extracted through concave electrodes

The self-focusing phenomenon has been observed in a high current density and low energy ion beam. In order to study the mechanism of this phenomenon, a special designed double probe to measure the electron density and temperature is installed into the chamber where the high current density ion beam is injected. Electron density profile is successfully measured without the influence of the ion beam components. Estimated electron temperature and density are ∼0.9 eV and ∼8 × 10{sup 8} cm{sup −3} at the center of ion beam cross section, respectively. It was found that a large amount of electrons are spontaneously accumulated in the ion beam line in the case of self-forcing state.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-F-T-149: Development of the Monte Carlo Simulation Platform Using Geant4 for Designing Heavy Ion Therapy Beam Nozzle

Purpose: The significant issue of particle therapy such as proton and carbon ion was a accurate dose delivery from beam line to patient. For designing the complex delivery system, Monte Carlo simulation can be used for the simulation of various physical interaction in scatters and filters. In this report, we present the development of Monte Carlo simulation platform to help design the prototype of particle therapy nozzle and performed the Monte Carlo simulation using Geant4. Also we show the prototype design of particle therapy beam nozzle for Korea Heavy Ion Medical Accelerator (KHIMA) project in Korea Institute of Radiological and Medical Science(KIRAMS) at Republic of Korea. Methods: We developed a simulation platform for particle therapy beam nozzle using Geant4. In this platform, the prototype nozzle design of Scanning system for carbon was simply designed. For comparison with theoretic beam optics, the beam profile on lateral distribution at isocenter is compared with Mont Carlo simulation result. From the result of this analysis, we can expected the beam spot property of KHIMA system and implement the spot size optimization for our spot scanning system. Results: For characteristics study of scanning system, various combination of the spot size from accerlator with ridge filter and beam monitor was tested as simple design for KHIMA dose delivery system. Conclusion: In this report, we presented the part of simulation platform and the characteristics study. This study is now on-going in order to develop the simulation platform including the beam nozzle and the dose verification tool with treatment planning system. This will be presented as soon as it is become available.

60 APPLIED LIFE SCIENCES↗

Complete Status Report Documenting the Development of Friction Stir Welding for Producing a Butt Joint in Thin Wall Tubing of ODS Alloys

A challenging attempt using friction stir welding to produce a butt joint between two 1.0 mm thick plates of 14YWT was nearly successful. The modified tool pin mostly penetrated the thickness of the adjoined thin plate samples resulting in a small blunt notch on the bottom surface of the butt joint. A bend occurred in the thin plate sample due to formation of stresses from clamping the thin plate sample during FSW. The peak displacement of the bend occurred along the center line of the butt joint. The weld zone showed good microstructure mixing with some flashing mostly on the retreating side that suggested excess heat input by friction between the traveling and spinning tool pin and thin plates of 14YWT. Neutron diffraction experiments were performed on the bent sample of 14YWT to measure the residual stresses in the butt joint on the HB-2B beam line at the Neutron Residual Stress Facility at HFIR. However, the neutron scattering to background noise ratio was very low during data acquisition. Measurements of lattice strains were obtained in the rolling (RD) and normal (ND) directions but not in the extrusion direction (ED) of the thin plate sample. Unfortunately, the quality of the data was not sufficient for determining the residual stresses in the butt joint. From the previous neutron scattering experiments conducted on four hot rolled plates (R1, R2, R3 and R4) of 14YWT, the residual stresses were calculated from lattice strain data and plotted in 2-D color contour maps for ED, RD and ND. The results showed variations in the magnitude and spatial position of residual stresses in the microstructure of the four plates. The magnitude in residual stresses in ED and RD increased gradually with increasing rolling deformation for R1 (50%) to R2 (76%), followed by larger increases in R3 (89%) and R4 (95%). The maximum peaks in residual stresses for R4 was ~710-730 MPa in ED and RD. The residual stresses in ND were below ~300 MPa for each of the 4 rolled plates, with a maximum residual stress in R4 (95%) of ~400 MPa. These results indicated that significant residual stresses representing ~57% of the yield stress of 14YWT (SM13) had accumulated in the 14YWT plate after hot rolling to the 1 mm thickness, which was used in the FSW experiments. The microstructure analysis of the 1.0 mm thick plate of 14YWT containing the butt joint produced by FSW revealed significant changes in the grain structure and texture between the unaffected zone (UZ) of the rolled plate and the butt joint weld. In the UZ, the grains were severely elongated after 95% deformation and mainly possessed the {101} texture component in the ED. Two predominant grain misorientation angles were observed: one consisting of small misorientations of <5º between highly elongated grains and the other consisting of large misorientations of >15º in pockets of small grains that might have formed by dynamic recrystallization processes during rolling of the plate at 1000ºC. The morphology and texture of grains in the heat affected zone (HAZ) were similar to those in UZ, except the grains had coarsened due to excess heat input during FSZ. A population of pores formed and the grains both coarsened and changed to isotropic morphology in the microstructure of the butt joint on both the advancing and retreating sides. The texture of grains in both regions were randomly orientated between the 3 poles {001}, {101} and {111}. The main difference in texture of grains between the advancing side and retreating side was with the misorientation angles of neighboring grains. Most of the grains in the advancing side had misorientation angles of >5º indicating that these grains experienced recrystallization. On the retreating side, areas containing larger grains showed high misorientation angles of >15º compared to areas appearing as bands of grains with misorientation angles of <5º and between 5º-15º. Numerous small pockets of grains with low misorientation angles of <5º were distributed in the microstructure among the grains showing high misorientation angles of >15º. It was determined that the grains associated with low misorientation angles contained sub-grain structures, which was consistent with both recrystallization and recovery mechanisms for grains located on the retreating side of the butt joint. These results demonstrate the complex microstructure that evolves in the microstructure of 14YWT resulting from the input of high temperatures and severe deformations during FSW.

36 MATERIALS SCIENCE↗

Soil Activation and Groundwater Contamination at Brookhaven National Laboratory, Upton, New York

In November 1999, tritium (H-3) was detected in the groundwater near one of Brookhaven National Laboratory's (BNL) accelerator experiments at concentrations above the 20,000 pico curie per liter (pCi/L) Maximum Contaminant Level (MCL). Sodium-22 (Na-22) was also detected in the groundwater, but at concentrations well below the 400 pCi/L MCL. An investigation into the source of the contamination revealed that the tritium and sodium-22 originated from activated soil shielding located adjacent to the g-2 target building where approximately five percent of the beam was inadvertently striking one of the beam-line magnets. Rainwater was able to infiltrate the activated soils and carry the tritium and sodium-22 into the groundwater. The highest tritium level detected in groundwater during the 1999 investigation was nearly 1.8 million pCi/L. To prevent additional rainwater infiltration into the activated soil shielding, a concrete cap was constructed over the soil shielding in December 1999. Other corrective actions included refocusing the beam and improved beam loss monitoring to reduce additional soil activation, storm-water management improvements, and additional groundwater monitoring. From 2001 through 2004, three high concentration zones (or slugs) of tritium were observed passing through the groundwater monitoring well network immediately down-gradient of the source area, with a maximum observed concentration of 3.4 million pCi/L. Some of the tritium that was previously leached from the activated soil was trapped in the vadose (unsaturated) zone soils directly above the water table after then cap was installed. A portion of this residual tritium was later mobilized into the groundwater during periods of high groundwater table elevations, which can occur following heavy seasonal rainfall. Monitoring results for the past two years indicate that the amount of tritium being released from the vadose zone is decreasing, with tritium concentrations consistently below 100,000 pCi/L. The tritium plume is currently 550 meters long, and is located entirely in the central portion of the BNL site. The plume has not impacted any of the Laboratory's drinking water supply wells. Contaminant transport modeling suggests that the tritium plume will attenuate entirely in the central portion of the BNL site by years 2010-2015. (authors)

54 ENVIRONMENTAL SCIENCES↗

Single Crystal Diamond Beam Position Monitors with Radiofrequency Electronic Readout

Over the energy range 5{approx}30 keV a suitably contacted, thin ({approx}100 {mu}m) diamond plate can be operated in situ as a continuous monitor of X-ray beam intensity and position as the diamond absorbs only a small percentage of the incident beam. Single crystal diamond is a completely homogeneous material showing fast (ns), spatially uniform signal response and negligible (<pA) leakage currents. Due to its unsurpassed thermal conductivity, it is the only semiconductor material that can be used in intense synchrotron white beams. We report on tests made at ESRF and DESY using diamond beam position monitors of simple quadrant electrode designs with metal contacts, operated using wideband electronic readout corresponding to the RF accelerator frequency. The instrumentation for these monitors must cover a large range of operating conditions: different beam sizes, fluxes, energies and time structure corresponding to the synchrotron fill patterns. Sophisticated new RF sampling electronics can satisfy most requirements: using a modified Libera Brilliance readout system, we measured the center of gravity position of a 25 {mu}m beam at the DORIS III F4 beam line at a rate of 130 Msample/s with narrowband filtering of a few MHz bandwidth. Digitally averaging the signal further provided a spatial resolution {approx}20 nm.

43 PARTICLE ACCELERATORS↗

In situ TEM and synchrotron characterization of U–10Mo thin specimen annealed at the fast reactor temperature regime

U–Mo metallic alloys have been extensively used for the Reduced Enrichment for Research and Test Reactors (RERTR) program, which is now known as the Office of Material Management and Minimization under the Conversion Program. This fuel form has also recently been proposed as fast reactor metallic fuels in the recent DOE Ultra-high Burnup Fast Reactor project. In order to better understand the behavior of U–10Mo fuels within the fast reactor temperature regime, a series of annealing and characterization experiments have been performed. Annealing experiments were performed in situ at the Intermediate Voltage Electron Microscope (IVEM-Tandem) facility at Argonne National Laboratory (ANL). An electro-polished U–10Mo alloy fuel specimen was annealed in situ up to 700 °C. At an elevated temperature of about 540 °C, the U–10Mo specimen underwent a relatively slow microstructure transition. Nano-sized grains were observed to emerge near the surface. At the end temperature of 700 °C, the near-surface microstructure had evolved to a nano-crystalline state. In order to clarify the nature of the observed microstructure, Laue diffraction and powder diffraction experiments were carried out at beam line 34-ID of the Advanced Photon Source (APS) at ANL. Phases present in the as-annealed specimen were identified with both Laue diffraction and powder diffraction techniques. The U–10Mo was found to recrystallize due to thermally-induced recrystallization driven by a high density of pre-existing dislocations. A separate in situ annealing experiment was carried out with a Focused Ion Beam processed (FIB) specimen. A similar microstructure transition occurred at a lower temperature of about 460 °C with a much faster transition rate compared to the electro-polished specimen. - Highlights: • TEM annealing experiments were performed in situ at the IVEM facility up to fast reactor temperature. • At 540 °C, the U-10Mo specimen underwent a slow microstructure transition where nano-sized grains were observed to emerge. • UO{sub 2} phase exists at the thin area of the as-annealed specimen whereas U-10Mo γ phase dominated at the thicker part. • Bcc γ U-10Mo recrystallized to become nano-meter sized crystallites near the specimen surface. • A separateannealing experiment was conducted with a FIB processed specimen where similar transition occurred at a lower temperature of 460 °C with a faster rate.

36 MATERIALS SCIENCE↗

E906/SeaQuest MARS15 Simulation

The E906/SeaQuest spectrometer is designed to measure high energy muons produced in the forward direction by interactions of the 120 GeV Main Injector proton beam with a variety of targets. The spectrometer consists of two dipole magnets (both of which deflect charged particles in the horizontal plane) and a collection of tracking detectors. The first spectrometer magnet (FMAG) is a solid iron magnet. This magnet serves as a beam dump as well as a muon analysis magnet. A series of MARS15 simulations were done by Nikolai Mokhov to verify and guide the design of concrete shielding around FMAG and the target area immediately upstream of FMAG. The result of the fourth and last round of simulations is summarized here. This was a high statistics simulation that required approximately 48 cpu-weeks of computing time on the APC Energy Deposition Group cluster. The MARS15 simulation used a model of FMAG and its surroundings. The model includes air gaps in the concrete shielding, the largest of which are required because of the geometry of the saddle coils. A small volume surrounding the beam line just upstream of the magnet is filled with borated polyethylene. The borated polyethylene extends into the air gap necessitated by the saddle coils. With the exception of the top layer of six 'H' blocks, the concrete shielding is modeled in detail. The top layer of blocks are intended to shield the roof and downstream end of NM4 in the event of a loss of beam accident well upstream of the target; they provide only a small benefit in the normal running condition simulated by MARS.

43 PARTICLE ACCELERATORS↗

First-ever deployment of a SiPM-on-tile calorimeter in a collider: a parasitic test with 200 GeV p p collisions at RHIC.

We describe the testing of a prototype SiPM-on-tile iron-scintillator calorimeter at the Relativistic Heavy Ion Collider (RHIC) during its 200 GeV p p run in 2024. The prototype, measuring 20 × 20 cm 2 and 24 radiation lengths in depth, was positioned in the STAR experimental hall, approximately 8 m from the interaction point and 65 cm from the beam line, covering a pseudorapidity range of about 3.1 < η < 3.4. By using the dark current of a reference SiPM as a radiation monitor, we estimate that the prototype was exposed to a fluence of about 10 10 1-MeV n eq /cm 2 . Channel-by-channel calibration was performed in a data-driven way with the signature from minimum-ionizing particles during beam-on conditions. AGeant4 detector simulation, with inputs from thePythia8 event generator, describes measurements of energy spectra and hit multiplicities reasonably well. These results mark the first deployment, commissioning, calibration, and long-term operation of a SiPM-on-tile calorimeter in a collider environment. This experimental campaign will guide detector designs and operational strategies for the ePIC detector at the future EIC, as well as other applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

MANX, a 6-D Muon Beam Cooling Experiment for RAL

MANX is a six-dimensional muon ionization cooling demonstration experiment based on the concept of a helical cooling channel in which a beam of muons loses energy in a continuous helium or hydrogen absorber while passing through a special superconducting magnet called a helical solenoid. The goals of the experiment include tests of the theory of the helical cooling channel and the helical solenoid implementation of it, verification of the simulation programs, and a demonstration of effective six-dimensional cooling of a muon beam. We report the status of the experiment and in particular, the proposal to have MANX follow MICE at the Rutherford-Appleton Laboratory (RAL) as an extension of the MICE experimental program. We describe the economies of such an approach which allow the MICE beam line and much of the MICE apparatus and expertise to be reused.

43 PARTICLE ACCELERATORS↗

Current capabilities and future needs for semiconductor ion implantation (invited)

For many years the largest commercial application for particle accelerators has been semiconductor ion implantation. These tools differ from other accelerators in many respects. In particular they are automated to a very high degree and, in addition to technical performance requirements their success depends on other key metrics including productivity, availability and cost of ownership. These tools also operate with a large variety of species, four orders of magnitude of energy range and five orders of magnitude of dose range. The ion source is a key component of implanters with its own performance metrics that include beam current, lifetime, and materials cost. In this paper, we describe the primary applications for ion implantation and some of the beam line architectures that are used. We describe the ion source that has evolved for this application. Some key future challenges for implanter ion source development are also discussed.

36 MATERIALS SCIENCE↗

Simulation of a cascaded longitudinal space charge amplifier for coherent radiation generation

Longitudinal space charge (LSC) effects are generally considered as harmful in free-electron lasers as they can seed unfavorable energy modulations that can result in density modulations with associated emittance dilution. It was pointed out, however, that such \micro-bunching instabilities" could be potentially useful to support the generation of broadband coherent radiation. Therefore there has been an increasing interest in devising accelerator beam lines capable of controlling LSC induced density modulations. In the present paper we augment these previous investigations by combining a grid-less space charge algorithm with the popular particle-tracking program elegant. This high-fidelity model of the space charge is used to benchmark conventional LSC models. We then employ the developed model to optimize the performance of a cascaded longitudinal space charge amplifier using beam parameters comparable to the ones achievable at Fermilab Accelerator Science & Technology (FAST) facility currently under commissioning at Fermilab.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗