Search NASA⌕ Search

SEARCH · Search NASA

Results for “Beam Distribution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

Generating Ultrashort Coherent Soft X-ray Radiation in Storage Rings Using Angular-modulated Electron Beams

A technique is proposed to generate ultrashort coherent soft x-ray radiation in storage rings using angular-modulated electron beams. In the scheme a laser operating in the TEM01 mode is first used to modulate the angular distribution of the electron beam in an undulator. After passing through a special beam line with non-zero transfer matrix element R{sub 54}, the angular modulation is converted to density modulation which contains considerable higher harmonic contents of the laser. It is found that the harmonic number can be one or two orders of magnitude higher than the standard coherent harmonic generation method which relies on beam energy modulation. The technique has the potential of generating femtosecond coherent soft x-ray radiation directly from an infrared seed laser and may open new research opportunities for ultrafast sciences in storage rings.

43 PARTICLE ACCELERATORS↗

Effect of nonuniform radial density distribution on the space charge dominated beam bunching

Beam dynamics of a space charge dominated beam during the bunch compression is studied self consistently for the case of fixed shape non-uniform bell shape and hollow shape density distributions in the transverse direction. We have used thick slices at different parts of the beam to account for variation in the beam radius in the study of the transverse dynamics. The longitudinal dynamics has been studied using the disc model. The axial variation of the radius of the slices and emittance growth arising from the phase dependence of the transverse rf forces are also included in the simulation. We have modified the beam envelope equation to take into account the longitudinal space charge effect on the transverse motion which arises due to the finite bunch size. To demonstrate the application of the theoretical formulations developed, we have studied a sinusoidal beam bunching system and presented detailed numerical results.

43 PARTICLE ACCELERATORS↗

IBS for non-gaussian distributions

In many situations distribution can significantly deviate from Gaussian which requires accurate treatment of IBS. Our original interest in this problem was motivated by the need to have an accurate description of beam evolution due to IBS while distribution is strongly affected by the external electron cooling force. A variety of models with various degrees of approximation were developed and implemented in BETACOOL in the past to address this topic. A more complete treatment based on the friction coefficient and full 3-D diffusion tensor was introduced in BETACOOL at the end of 2007 under the name 'local IBS model'. Such a model allowed us calculation of IBS for an arbitrary beam distribution. The numerical benchmarking of this local IBS algorithm and its comparison with other models was reported before. In this paper, after briefly describing the model and its limitations, they present its comparison with available experimental data.

43 PARTICLE ACCELERATORS↗

Wave generation by contaminant ions

Investigations dealing with the generation of waves by contaminant ions are reported. The studies included the properties of the velocity distribution function of such ions. It was found that it takes about one ion-cyclotron period for the distribution function to transform from a beam to a ring distribution. A linear instability analysis was performed to examine the possibility of wave excitation by an ion beam streaming perpendicular to the ambient magnetic field in an ionospheric type of plasma. A simulation code was developed to study the nonlinear behavior of the waves excited by beam and ring types of ion distributions. The code treats both electrons and ions as particles kinetically to also factor in the possible involvement of lower-hybrid waves.

Singh, N.↗

SU-E-T-409: Evaluation of Tissue Composition Effect On Dose Distribution in Radiotherapy with 6 MV Photon Beam of a Medical Linac

Purpose: The aim of this study is to evaluate soft tissue composition effect on dose distribution for various soft tissues and various depths in radiotherapy with 6 MV photon beam of a medical linac. Methods: A phantom and Siemens Primus linear accelerator were simulated using MCNPX Monte Carlo code. In a homogeneous cubic phantom, six types of soft tissue and three types of tissue-equivalent materials were defined separately. The soft tissues were muscle (skeletal), adipose tissue, blood (whole), breast tissue, soft tissue (9-component) and soft tissue (4-component). The tissue-equivalent materials included: water, A-150 tissue-equivalent plastic and perspex. Photon dose relative to dose in 9-component soft tissue at various depths on the beam’s central axis was determined for the 6 MV photon beam. The relative dose was also calculated and compared for various MCNPX tallies including,F8, F6 and,F4. Results: The results of the relative photon dose in various materials relative to dose in 9-component soft tissue and using different tallies are reported in the form of tabulated data. Minor differences between dose distributions in various soft tissues and tissue-equivalent materials were observed. The results from F6 and F4 were practically the same but different with,F8 tally. Conclusion: Based on the calculations performed, the differences in dose distributions in various soft tissues and tissue-equivalent materials are minor but they could be corrected in radiotherapy calculations to upgrade the accuracy of the dosimetric calculations.

60 APPLIED LIFE SCIENCES↗

Quasi-Isochronous Muon Capture

Intense muon beams have many potential applications, including neutrino factories and muon colliders. However, muons are produced as tertiary beams, resulting in diffuse phase space distributions. To make useful beams, the muons must be rapidly cooled before they decay. An idea conceived recently for the collection and cooling of muon beams, namely, the use of a Quasi-Isochronous Helical Channel (QIHC) to facilitate capture of muons into RF buckets, has been developed further. The resulting distribution could be cooled quickly and coalesced into a single bunch to optimize the luminosity of a muon collider. After a brief elaboration of the QIHC concept, some recent developments are described.

43 PARTICLE ACCELERATORS↗

Quasi-isochronous Muon Collection Channels

Intense muon beams have many potential applications, including neutrino factories and muon colliders. However, muons are produced as tertiary beams, resulting in diffuse phase space distributions. To make useful beams, the muons must be rapidly cooled before they decay. An idea conceived recently for the collection and cooling of muon beams, namely, the use of a Quasi-Isochronous Helical Channel (QIHC) to facilitate capture of muons into RF buckets, has been developed further. The resulting distribution could be cooled quickly and coalesced into a single bunch to optimize the luminosity of a muon collider. After a brief elaboration of the QIHC concept, recent developments are described.

43 PARTICLE ACCELERATORS↗

Probe measurements of the electron distribution function in an electron-beam-produced ytterbium plasma

A nonequilibrium anisotropic plasma produced by an electron beam in the residual air with a low content of ytterbium vapor was investigated by the probe method. It is found that a minor (at a level of a few ppm) admixture of ytterbium to low-pressure air substantially modifies the electron energy distribution function (EEDF): the main peak corresponding to thermal electrons broadens, and new peaks appear. It is shown that the observed change in the EEDF is caused by the low ionization energy of ytterbium, due to which one beam electron can ionize several ytterbium atoms. The new peaks in the EEDF correspond to the final energies of a beam electron after each subsequent ionizing collision with ytterbium atoms.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Intra-Beam and Touschek Scattering Computations for Beam with Non-Gaussian Longitudinal Distributions

Both intra-beamscattering (IBS) and the Touschek effect become prominent formulti-bend-achromat- (MBA-) based ultra-low-emittance storage rings. To mitigate the transverse emittance degradation and obtain a reasonably long beam lifetime, a higher harmonic rf cavity (HHC) is often proposed to lengthen the bunch. The use of such a cavity results in a non-gaussian longitudinal distribution. However, common methods for computing IBS and Touschek scattering assume Gaussian distributions. Modifications have been made to several simulation codes that are part of the elegant [1] toolkit to allow these computations for arbitrary longitudinal distributions. After describing thesemodifications, we review the results of detailed simulations for the proposed hybrid seven-bend-achromat (H7BA) upgrade lattice [2] for the Advanced Photon Source.

Xiao, A.↗

Ion-beam mixing in crystalline and amorphous germanium isotope multilayers

Gallium (Ga) implantation induced self-atom mixing in crystalline and amorphous germanium (Ge) is investigated utilizing isotopically controlled Ge multilayer structures grown by molecular beam epitaxy. The distribution of the Ga ions and the ion-beam induced depth-dependent mixing of the isotope structure was determined by means of secondary ion mass spectrometry. Whereas the distribution of Ga in the crystalline and amorphous Ge is very similar and accurately reproduced by computer simulations based on binary collision approximation (BCA), the ion-beam induced self-atom mixing is found to depend strongly on the state of the Ge structure. The experiments reveal stronger self-atom mixing in crystalline than in amorphous Ge. Atomistic simulations based on BCA reproduce the experimental results only when unphysically low Ge displacement energies are assumed. Analysis of the self-atom mixing induced by silicon implantation confirms the low displacement energy deduced within the BCA approach. This demonstrates that thermal spike mixing contributes significantly to the overall mixing of the Ge isotope structures. The disparity observed in the ion-beam mixing efficiency of crystalline and amorphous Ge indicates different dominant mixing mechanisms. We propose that self-atom mixing in crystalline Ge is mainly controlled by radiation enhanced diffusion during the early stage of mixing before the crystalline structure turns amorphous, whereas in an already amorphous state self-atom mixing is mediated by cooperative diffusion events.

36 MATERIALS SCIENCE↗

Measuring of plasma properties induced by non-vacuum electron beam welding

Electron beam plasma measurement was realised by means of DIABEAM system invented by ISF RWTH Aachen. The Langmuir probe method is used for measurement. The relative simplicity of the method and the possibility of dispersion of high power on the probe allow its application for the investigation of high-power electron beams. The key element of the method is a rotating thin tungsten wire, which intersects the beam transversely on its axis and collects part of the current by itself. The signals, which are registered in the DIABEAM as a voltage, were taken in the form of amplitude. The conversion of the probe current into the distribution along the beam radius was realised using the Abel's method. A voltage-current characteristic was built for the beam current. The local electron density as well as the electron temperature, the floating potential and the plasma potential were measured and calculated by means of this characteristic.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Field-size dependence of doses of therapeutic carbon beams

To estimate the physical dose at the center of spread-out Bragg peaks (SOBP) for various conditions of the irradiation system, a semiempirical approach was applied. The dose at the center of the SOBP depends on the field size because of large-angle scattering particles in the water phantom. For a small field of 5x5 cm{sup 2}, the dose was reduced to 99.2%, 97.5%, and 96.5% of the dose used for the open field in the case of 290, 350, and 400 MeV/n carbon beams, respectively. Based on the three-Gaussian form of the lateral dose distributions of the carbon pencil beam, which has previously been shown to be effective for describing scattered carbon beams, we reconstructed the dose distributions of the SOBP beam. The reconstructed lateral dose distribution reproduced the measured lateral dose distributions very well. The field-size dependencies calculated using the reconstructed lateral dose distribution of the therapeutic carbon beam agreed with the measured dose dependency very well. The reconstructed beam was also used for irregularly shaped fields. The resultant dose distribution agreed with the measured dose distribution. The reconstructed beams were found to be applicable to the treatment-planning system.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-F-T-178: Optimized Design of a Diamond Detector Specifically Dedicated to the Dose Distribution Measurements in Clinical Proton Pencil Beams

Purpose: In proton-therapy, pencil beam scanning (PBS) dosimetry presents a real challenge due to the small size of the beam (about 3 to 8 mm in FWHM), the pulsed high dose rate (up to 100 Gy/s) and the proton energy variation (about 30 MeV to 250 MeV). In the framework of French INSERM DEDIPRO project, a specifically dedicated single crystal diamond dosimeter (SCDDo) was developed with the objective of obtaining accurate measurements of the dose distribution in PBS modality. Methods: Monte Carlo simulations with MCNPX were performed. A small proton beam of 5 mm in FWHM was simulated as well as diamond devices with various size, thickness and holder composition. The calculated doses-to-diamond were compared with the doses-to-water in order to reduce the perturbation effects. Monte-Carlo simulations lead to an optimized SCDDo design for small proton beams dosimetry. Following the optimized design, SCDDos were mounted in water-equivalent holders with electrical connection adapted to standard electrometer. First, SCDDos performances (stability, repeatability, signal-to-background ratio…) were evaluated with conventional photon beams. Then, characterizations (dose linearity, dose rate dependence…) with wide proton beams were performed at proton-therapy center (IC-CPO) from Curie Institute (France) with the passive proton delivery technique, in order to confirm dosimetric requirements. Finally, depth-dose distributions were measured in a water tank, for native and modulated Bragg Peaks with the collimator of 12 cm, and compared to a commercial PPC05 parallel-plate ionization chamber reference detector. Lateral-dose profiles were also measured with the collimator of 5 mm, and compared to a commercial SFD diode. Results: The results show that SCDDo design does not disturb the dose distributions. Conclusion: The experimental dose distributions with the SCDDo are in good agreement with the commercial detectors and no energy dependence was observed with this device configuration.

07 ISOTOPE AND RADIATION SOURCES↗

Direct measurement of the Kirkwood-Rihaczek distribution for the spatial properties of a coherent light beam

We present a direct measurement of the Kirkwood-Rihaczek (KR) distribution for spatial properties of a coherent light beam in terms of position and momentum (angle) coordinates. We employ a two-local oscillator (LO) balanced heterodyne detection (BHD) to simultaneously extract the distribution of the transverse position and momentum of a light beam. The two-LO BHD can measure the KR distribution for any complex wave field (including quantum mechanical wave function) without applying tomography methods (inverse Radon transformation). The transformation of the KR distribution to the Wigner, Glauber-Sudarshan P, and Husimi or Q distributions in spatial coordinates are illustrated through experimental data. The KR distribution can provide the local information of a wave field, which is suitable for studying particle properties of a quantum system. Meanwhile, the Wigner function is suitable for studying wave properties such as interference, and hence provides nonlocal information of the wave field. The method developed here can be used for exploring the spatial quantum state for information processing and optical phase-space imaging for biomedical applications.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Intial characterization fo a commerical electron gun for profiling high intensity proton beams in Project X

Measuring the profile of a high-intensity proton beam is problematic in that traditional invasive techniques such as flying wires don't survive the encounter with the beam. One alternative is the use of an electron beam as a probe of the charge distribution in the proton beam as was done at the Spallation Neutron Source at ORNL. Here we present an initial characterization of the beam from a commercial electron gun from Kimball Physics, intended for use in the Fermilab Main Injector for Project X. Despite the fact that the horizontal spot size is abnormally large in the high current measurement, the spot size at the downstream cross X2 is reasonable in the context of measuring the deflection. A thin foil OTR would help with the beam heating and should be tried. The next phase of this experiment is to simulate the proton beam with a pair of current carrying wires and to design and construct a fast deflector. Some of the remaining issues to be considered include determining the minimum beam current needed to observe the deflected beam for a given sweep time and the impact of longitudinal variations in the charge density of the bunch.

43 PARTICLE ACCELERATORS↗

NIO1 diagnostics

The radio frequency ion source NIO1, jointly developed by Consorzio RFX and INFN-LNL, will generate a 60kV-135mA hydrogen negative ion beam, composed of 9 beamlets over an area of about 40 × 40 mm{sup 2}. This experiment will operate in continuous mode and in conditions similar to those foreseen for the larger ion sources of the Neutral Beam Injectors for ITER. The modular design of NIO1 is convenient to address the several still open important issues related to beam extraction, optics, and performance optimization. To this purpose a set of diagnostics is being implemented. Electric and water cooling plant related measurements will allow monitoring current, pressure, flow, and temperature. The plasma in the source will be characterized by emission spectroscopy, cavity ring-down and laser absorption spectroscopy. The accelerated beam will be analyzed with a fast emittance scanner, its intensity profile and divergence with beam emission spectroscopy and visible tomography. The power distribution of the beam on the calorimeter will be monitored by thermocouples and by an infrared camera. This contribution presents the implementation and initial operation of some of these diagnostics in the commissioning phase of the experiment, in particular the cooling water calorimetry and emission spectroscopy.

43 PARTICLE ACCELERATORS↗

Measurement techniques using the electron beam profile scanner at the Fermilab Main Injector

This work presents techniques for non-invasive transverse profile measurements of high-intensity proton beams using an Electron Beam Profile Scanner (EBPS). The EBPS utilizes low-energy electrons as a probe to analyze the transverse size of proton beams, allowing for potential analysis on a single-bunch basis. Recent upgrades to the Fermilab Main Injector have enhanced beam power on target to 1 MW, with future developments targeting 2 MW. The higher beam power has increased the demand for non-invasive diagnostics, as invasive methods can disrupt operations.The techniques presented include 1) the slow scan technique, which serves as a proof of concept for the probe beam, 2) the one-shot scan technique for measuring horizontal beam profiles, and 3) the raster scan technique for analyzing horizontal beam profiles as a function of the longitudinal distribution of the beam. The profiles obtained will be crucial for studying and understanding instabilities in high-power, high-intensity proton beams. This will contribute to optimizing the operation of high-power proton accelerators by minimizing beam loss, activation, and damage to both the diagnostics and the accelerator components.

Mwaniki, Matilda [IIT, Chicago]↗

Saturation of fluorescence in flames with a Gaussian laser beam

The method of saturated fluorescence for measuring species concentrations in flames is usually performed with laser beams that do not provide a constant intensity distribution across the focal volume. Because of the intensity distribution across the beam, the fluorescence signal does not depend on laser power or intensity in the same manner as for uniform illumination. This leads to anomolous apparent saturation intensities. In the following, the effect is considered for atomic fluorescence. Relations for the fluorescence signal under two common excitation geometries are derived and uncertainty relations used to consider the benefits of high laser intensity.

Daily, J. W.↗