Knowledge-based approach to system integration

To solve complex problems one can often use the decomposition principle. However, a problem is seldom decomposable into completely independent subproblems. System integration deals with problem of resolving the interdependencies and the integration of the subsolutions. A natural method of decomposition is the hierarchical one. High-level specifications are broken down into lower level specifications until they can be transformed into solutions relatively easily. By automating the hierarchical decomposition and solution generation an integrated system is obtained in which the declaration of high level specifications is enough to solve the problem. We offer a knowledge-based approach to integrate the development and building of control systems. The process modeling is supported by using graphic editors. The user selects and connects icons that represent subprocesses and might refer to prewritten programs. The graphical editor assists the user in selecting parameters for each subprocess and allows the testing of a specific configuration. Next, from the definitions created by the graphical editor, the actual control program is built. Fault-diagnosis routines are generated automatically as well. Since the user is not required to write program code and knowledge about the process is present in the development system, the user is not required to have expertise in many fields.

Blokland, W.↗

Properties of PMR Polyimides Improved by Preparation of Polyhedral Oligomeric Silsesquioxane (POSS) Nanocomposites

The field of hybrid organic-inorganic materials has grown drastically over the last several years. This interest stems from our ever-increasing ability to custom-build and control molecular structure at several length scales. This ability to control both the composition and structure of hybrid materials is sometimes broadly referred to as nanocomposite systems. One class of hybrid (organic-inorganic) nanostructured material is polyhedral oligomeric silsesquioxane (POSS), shown in the preceding diagram. The hybrid composition gives POSS materials dramatically enhanced properties relative to traditional hydrocarbons and inorganics. An important benefit of this technology is that it makes possible the formulations of nanostructured chemicals with excellent thermal and oxidative stability. This is largely due to the inorganic component.

Campbell, Sandi G.↗

Propulsion Component Test Capabilities at MSFC’s Test Stand 115

Marshall Space Flight Center’s Test Stand 115 (TS115) is a propulsion component test facility in operation since its original activation in 1964 for testing small to medium size liquid rocket engine components including injectors, channel-cooled chambers, nozzles, passively-cooled metallic and composite nozzle extensions, valves, turbomachinery, and igniters. TS115 is a "blowdown" type facility, using high pressure tankage and components to provide liquid, gaseous, and cryogenic fluid delivery at specified pressures and flowrates. The facility consists of an open steel test stand structure, a mechanical hardware preparation shop, an electrical support equipment building, a control room, and a centralized data system room. In general, the facility infrastructure is rated to 3,000 psig. TS115 can accommodate thrust levels up to 10,000 lbf in the horizontal position. The facility is actively used for various internal NASA test programs as well as test campaigns for external customers from other government agencies, commercial industry partners, and academia. The available fluid systems, electrical power and instrumentation capabilities, facility controls and data acquisition systems, test program support capabilities, and available test rig configurations for external customer use are discussed in this paper.

Tal Wammen↗

Systems and methods for controlling energy use in a building management system using energy budgets

Systems and methods for limiting power consumption by a heating, ventilation, and air conditioning (HVAC) subsystem of a building are shown and described. A mathematical linear operator is found that transforms the unused or deferred cooling power usage of the HVAC system based on pre-determined temperature settings to a target cooling power usage. The mathematical operator is applied to the temperature settings to create a temperature setpoint trajectory expected to provide the target cooling power usage.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Integration of Photovoltaics into Building Energy Usage through Advanced Control of Rooftop Unit

This paper presents a computational approach to forecast photovoltaic (PV) power in kW based on a neural network linkage of publicly available cloud cover data and on-site solar irradiance sensor data. We also describe a control approach to utilize rooftop air conditioning units (RTUs) to support renewable integration. The PV forecasting method is validated using data from a rooftop PV panel installed on the Distributed Energy, Communications, and Controls (DECC) laboratory at Oak Ridge National Laboratory. The validation occurs in multiple phases to ensure that each component of the approach is the best representation of the actual expected output. The control of the RTU is based on model predictive methods.

Starke, Michael R↗

Exploration Drilling and Technology Demonstration At Fort Bliss

The Tularosa-Hueco basin in south-central New Mexico has long been known as an extensional area of high heat flow. Much of the basin is within the Fort Bliss military reservation, which is an exceptionally high value customer for power independent of the regional electric grid and for direct use energy in building climate control. A series of slim holes drilled in the 1990s established the existence of a thermal anomaly but not its practical value. This study began in 2009 with a demonstration of new exploration drilling technology. The subsequent phases reported here delivered a useful well, comparative exploration data sets and encouragement for further development. A production-size well, RMI56-5, was sited after extensive study of archival and newly collected data in 2010-2011. Most of 2012 was taken up with getting state and Federal authorities to agree on a lead agency for permitting purposes, getting a drilling permit and redesigning the drilling program to suit available equipment. In 2013 we drilled, logged and tested a 924 m well on the McGregor Range at Fort Bliss using a reverse circulation rig. Rig tests demonstrated commercial permeability and the well has a 7-inch slotted liner for use either in production or injection. An August 2013 survey of the completed well showed a temperature of 90 C with no reversal, the highest such temperature in the vicinity. The well’s proximity to demand suggests a potentially valuable resource for direct use heat and emergency power generation. The drilling produced cuttings of excellent size and quality. These were subjected to traditional analyses (thin sections, XRD) and to the QEMScan™ for comparison. QEMScan™ technology includes algorithms for determining such properties of rocks as density, mineralogy, heavy/light atoms, and porosity to be compared with direct measurements of the cuttings. In addition to a complete cuttings set, conventional and resistivity image logs were obtained in the open hole before the well was cased.

15 GEOTHERMAL ENERGY↗

Innovative Glazing Materials

Windows have the unique capability of being able to achieve a net zero energy impact by admitting solar gains in the winter to offset thermal losses and admitting daylight to offset electric lighting. If rejection or admission of solar heat gains and daylight are appropriately timed, then heating, cooling and lighting energy use at the perimeter zone can be reduced to net zero energy levels. Nano-scale switchable coatings on glass have been developed to actively modulate solar intensity and spectral transmission. We provide a brief overview of these switchable glazing materials, discuss the desired performance objectives for such materials, and present results from recently completed monitored studies of state-of-the-art switchable windows, particularly with respect to occupant response and market factors. Careful application of state-of-the-art switchable windows and new material science developments on the horizon can deliver the desired net zero energy performance while meeting critical human factors and market related requirements.

Building energy efficiency↗

Developing High-Performance Computing Model of Vapor Transition Through Advanced Membranes for Applications in 7AC Liquid Desiccant Air Conditioners

This poster for the 2019 Advanced Manufacturing Office Peer Review covers the high-performance computing model development for applications in Liquid Desiccant Air Conditioners. Conventional compressor-based cooling has undergone incremental changes over the past 100 years. Further improvements in efficiency require evermore complex systems, especially under humid conditions. Microporous membranes offer unique opportunities for efficient humidity control in buildings using an absorbent desiccant solution, but membranes are not designed for this purpose. This project used molecular dynamic (MD) simulations to determine the effect of membrane properties on important metrics for these air-conditioning applications, focusing on the membrane properties at the membrane/liquid/air interface. Improved membranes can enable smaller, more durable, and less costly designs for these membrane air conditioning systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

DECENTRALIZED APPROACH TO MULTI-ZONE GREY-BOX MODELING FOR MODEL-BASED PREDICTIVE CONTROL

This study aims to improve the easiness of utilizing the grey-box model (i.e., Resistance-Capacitance circuit) for Model-based Predictive Control (MPC). The primary barrier of implementing the MPC is estimating the control-oriented building model that needs to be computationally inexpensive and quick but reasonably precise in predicting building load and indoor conditions. The estimating of the model parameters becomes more complicated when the building scale is larger; e.g., multi-zone building. In this study, a decentralized approach is introduced; each zone is split and individually estimated with measured boundary temperature from adjacent zones integrated into one single system model. The proposed decentralized method is demonstrated with experimental data from a full-scale multi-zone test cell compared with the centralized reference case.

Joe, Jaewan↗

Harvesting the low-hanging fruit of high energy savings -- Virtual Occupancy using Wi-Fi Data

Approximately 20% of primary energy consumed in the U.S. is attributed to HVAC use. Ideally, HVAC operation would be driven by actual building occupancy, but lack of reliable occupancy information often results in the use of conservative static schedules. This disparity is even more pronounced in a college campus, where the function of each space differs by building (classrooms, offices, libraries) and the class schedules change frequently -- every semester, day of week, and hour. While several research papers propose the use of counts of the Wi-Fi connections (e.g., phones, computers) as a proxy for occupancy, few real-world implementations exist. This paper describes the development and deployment of an open-source Wi-Fi-to-Occupancy software library in 65 buildings of a college campus, and the planned integration with the building energy management and control system at the building scale. Over a year of Wi-Fi data was gathered into distinct academic periods, including fall and spring semester, academic breaks, and summer sessions. Patterns such as students moving between classrooms, closing laptops before exams, etc., can be visualized from the data. Approximating occupancy from Wi-Fi data presents challenges which we address in this project -- for example, identifying static devices, or estimating the ratio of devices per person. Utilizing real-time occupancy data to inform optimal HVAC schedules and ventilation rates creates the potential to identify and reduce energy waste. Other potential applications include forecasting occupancy, and using Wi-Fi data to predict peak demands. Finally, the paper discusses how to easily scale these tools to other buildings.

Pritoni, Marco↗

Energy Systems Integration Facility Stewardship Summary: Fiscal Year 2023

A summary of NREL's good stewardship of the nationally unique Energy Systems Integration Facility (ESIF) highlighting performance metrics, infrastructure and capability upgrades, and examples of R&D impact. In fiscal year 2023, ESIF installed its third-generation high-performance computer, expanded capabailities for validating building energy controls, and demonstrated a leap in scale through virtual networking with another national laboratory. ESIF researchers made breakthroughs in cybersecurity for energy systems, efficient high-powered electric vehicle charging, leveraging reinforcement learning for grid resilience, and more.

ADVANCED PROPULSION SYSTEMS,ENERGY CONSERVATION, C↗

Oxadiazole-based Heterocycles as Building Block for Material Property Control: Design, Synthesis, and Characterization of 3,4-Bis(3-(4-nitro-1,2,5-oxadiazol-3-yl)- 1,2,4-oxadiazol-5-yl)-1,2,5-oxadiazole (LLM-210)

This paper presents an approach to novel oxadiazole-based melt-castable energetic material, LLM-210. Used in pour-in process and 3D printing, melt-castable energetic materials (MCEM) must possess required physical and safety properties of industry-standard energetic materials, also a narrow range of melting point between 80-100 °C. Melting point is difficult to accurately predict, therefore, searching for MCEM is challenging. 3,4-Bis(5-(4-nitro-1,2,5-oxadiazol-3-yl)-1,2,4-oxadiazol3-yl)-1,2,5-oxadiazole (LLM-205), composed of five-oxadiazole rings allied via carbon-carbon bonds, was selected as new MCEM candidate. The target molecule was synthesized and characterized, showing a density of 1.807g/cm3 ; thermal decomposing temperature at 299 °C; and insensitive to external stimuli, but the melting point of 104 °C was out of the rang. Based on the molecular properties and ab initio calculations, 3,4-bis(3-(4-nitro-1,2,5-oxadiazol-3-yl)-1,2,4-oxadiazol-5-yl)- 1,2,5-oxadiazole (LLM-210), an isomer of LLM-205, was designed and synthesized from a different way. LLM-210 was characterized as MCEM, possessing melting point of 87 °C; density of 1.812 g/cm3 ; and exothermally decomposing temperature at 314 °C; being insensitive to external stimuli. In this study, the relationship of molecular structure to properties of LLM-205 and LLM-210 based on the results of Density Functional Theory (DFT) and X-ray crystallographic analysis is also briefly discussed.

Chemistry - Chemical explosives↗

Modulating thermal load through lightweight residential building walls using thermal energy storage and controlled precooling strategy

Precooling is a recognized technique for reducing cooling energy in buildings during peak hours by shifting load to off-peak hours. This technique is particularly effective in buildings with high thermal mass, because of their large thermal energy storage capacity, and in commercial buildings due to their variable electricity pricing based on time-of-use rates. Precooling in residential buildings has been a matter of limited interest in the past because of their low thermal mass and typically uniform electricity pricing rate. While previous studies on precooling primarily focused on cost savings, an important aspect of precooling is the thermal load modulation, which could be very effective in managing peak demand in lightweight residential buildings integrated with thermal energy storage systems. In this study, we examine different precooling strategies to manage the heat gains in lightweight building walls integrated with phase-change materials. We create nine different precooling profiles by controlling the interior temperature, and then evaluate the influence of the precooling profiles on four key building energy performance parameters: total heat gain, peak heat gain, maximum heat gain during peak hours, and time at which peak occurs. To thoroughly understand the fundamental physics, we first consider hypothetical climates and obtain the optimal precooling strategy required to achieve maximum peak shedding and shifting while minimizing the total heat gains. We then extend the model to Baltimore, Maryland, and estimate the benefits of the optimized precooling strategy under real conditions. The optimal precooling strategy proposed in this study can shift the peak heat gain by up to 14 hours, thereby reducing the heat gain during peak period by up to 95%, at the expense of a 23% increase in the total heat gains.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Integration of thermally anisotropic building envelopes with TES and advanced controls to tailor HVAC loads

Heating, ventilation, and air conditioning (HVAC) systems are the primary energy consumers in buildings to meet heating or cooling energy demands. The building envelope can play an active role in reducing this demand and associated costs by collecting thermal energy naturally available, such as diurnal temperature swings, solar irradiance, and night sky radiation cooling, to offset heating and cooling loads.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Experimental Demonstration of Frequency Regulation by Commercial Buildings – Part I: Modeling and Hierarchical Control Design

Here, this paper is the first part of a two-part series in which we present results from one of the first worldwide experimental demonstrations of frequency regulation in a commercial building test facility. We demonstrate that commercial buildings can track a frequency regulation signal with high accuracy and minimal occupant discomfort in a realistic environment. In addition, we show that buildings can determine the reserve capacity and baseline power a priori, and identify the optimal tradeoff between frequency regulation and energy efficiency.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Lessons Learned from Industry Engagement in Export Controls

There are several U.S. government-sponsored programs with significant experience engaging with foreign government and industry partners to support capacity-building in export controls. This work seeks to answer the question: How can the outreach experience of the U.S. government-sponsored export control capacity-building programs (ECCBP) inform best practices for engaging with advanced reactor vendors in the domain of international nuclear safeguards? To answer this question, we interviewed export control subject matter experts with experience working for the U.S. ECCBPs – the Bureau of Industry and Security (BIS), the Export Control and Related Border Security (EXBS) program, and the International Nonproliferation Export Control Program (INECP) – and developed a set of recommendations for industry engagement based on the collective experience of interviewees.