Search NASA⌕ Search

SEARCH · Search NASA

Results for “CCD Camera”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

Videogrammetric Model Deformation Measurement Technique

The theory, methods, and applications of the videogrammetric model deformation (VMD) measurement technique used at NASA for wind tunnel testing are presented. The VMD technique, based on non-topographic photogrammetry, can determine static and dynamic aeroelastic deformation and attitude of a wind-tunnel model. Hardware of the system includes a video-rate CCD camera, a computer with an image acquisition frame grabber board, illumination lights, and retroreflective or painted targets on a wind tunnel model. Custom software includes routines for image acquisition, target-tracking/identification, target centroid calculation, camera calibration, and deformation calculations. Applications of the VMD technique at five large NASA wind tunnels are discussed.

Burner, A. W.↗

Array biosensor for detection of toxins

The array biosensor is capable of detecting multiple targets rapidly and simultaneously on the surface of a single waveguide. Sandwich and competitive fluoroimmunoassays have been developed to detect high and low molecular weight toxins, respectively, in complex samples. Recognition molecules (usually antibodies) were first immobilized in specific locations on the waveguide and the resultant patterned array was used to interrogate up to 12 different samples for the presence of multiple different analytes. Upon binding of a fluorescent analyte or fluorescent immunocomplex, the pattern of fluorescent spots was detected using a CCD camera. Automated image analysis was used to determine a mean fluorescence value for each assay spot and to subtract the local background signal. The location of the spot and its mean fluorescence value were used to determine the toxin identity and concentration. Toxins were measured in clinical fluids, environmental samples and foods, with minimal sample preparation. Results are shown for rapid analyses of staphylococcal enterotoxin B, ricin, cholera toxin, botulinum toxoids, trinitrotoluene, and the mycotoxin fumonisin. Toxins were detected at levels as low as 0.5 ng mL(-1).

Review↗

Solar Array in Simulated LEO Plasma Environment

Six different types of solar arrays have been tested in large vacuum chambers. The low Earth orbit plasma environment was simulated in plasma vacuum chambers, where the parameters could be controlled precisely. Diagnostic equipment included spherical Langmuir probes, mass spectrometer, low-noise CCD camera with optical spectrometer, video camera, very sensitive current probe to measure arc current, and a voltage probe to register variations in a conductor potential. All data (except video) were obtained in digital form that allowed us to study the correlation between external parameters (plasma density, additional capacitance, bias voltage, etc) and arc characteristics (arc rate, arc current pulse width and amplitude, gas species partial pressures, and intensities of spectral lines). Arc inception voltages, arc rates, and current collections are measured for samples with different coverglass materials and thickness, interconnect designs, and cell sizes. It is shown that the array with wrapthrough interconnects have the highest arc threshold and the lowest current collection. Coverglass design with overhang results in decrease of current collection and increase of arc threshold. Doubling coverglass thickness causes the increase in arc inception voltage. Both arc inception voltage and current collection increase significantly with increasing a sample temperature to 80 C. Sustained discharges are initiated between adjacent cells with potential differences of 40 V for the sample with 300 m coverglass thickness and 60 V for the sample with 150 m coverglass thickness. Installation of cryogenic pump in large vacuum chamber provided the possibility of considerable outgassing of array surfaces which resulted in significant decrease of arc rate. Arc sites were determined by employing a video-camera, and it is shown that the most probable sites for arc inception are triple-junctions, even though some arcs were initiated in gaps between cells. It is also shown that the arc rate increases with increasing of ion collection current. The analysis of optical spectra (240-800 nm) reveals intensive narrow atomic lines (Ag, H) and wide molecular bands (OH, CH, SiH, SiN) that confirms a complicated mechanism of arc plasma generation. The results obtained seem to be important for the understanding of the arc inception mechanism, which is absolutely essential for progress toward the design of high-voltage solar array for space application.

Vayner, Boris↗

Study of Cluster Formation and its Effects on Rayleigh and Raman Scattering Measurements in a Mach 6 Wind Tunnel

Using a frequency-doubled Nd-YAG pulsed laser and a single-intensified CCD camera, Rayleigh scattering measurements have been performed to study the cluster formation in a Mach 6 wind tunnel at NASA Langley Research Center. These studies were conducted both in the free stream and in a model flow field for various flow conditions to gain an understanding of the dependence of the Rayleigh scattering (by clusters) on the local pressures and temperatures in the facility. Using the same laser system, we have also performed simultaneous measurements of the local temperature using the rotational Raman scattering of molecular nitrogen and determined the densities of molecular oxygen and nitrogen by using the vibrational Raman scattering from these species. Quantitative results will be presented in detail with emphasis on the applicability of the Rayleigh scattering for obtaining quantitative measurements of molecular densities both in the free stream and in the model flow field.

Shirinzadeh, B.↗

Transitsearch Workshop

The discovery of more than 100 planets around nearby solar-like stars that surpass Jupiter in size yet orbit their stars more quickly than Mercury has heralded a new era in astronomy. These enigmatic 'Hot-Jupiters' are large enough and close enough to their parent stars that their 'transits' can be captured by astronomers equipped with a small computer controlled telescope and a quality electronic CCD camera. The planet reveals its presence through the periodic decrease in brightness as it passes (or transits) in front of the star as seen from Earth. The first known transiting extrasolar planet HD 209458b, in the constellation Pegasus, has been the subject of hundreds of scientific papers since its discovery in 1999. The transit of 8th magnitude HD 209458 has been observed by at least a dozen non-professional astronomers using telescopes as small as 4 inches in aperture. Using equipment already in hand, and armed with target lists, transit time predictions, observing techniques and software procedures developed by astronomers at NASA's Ames Research Center and the University of California at Santa Cruz, non-professional astronomers can contribute significantly to the study of extrasolar planets by carefully measuring the brightness of stars with known Hot-Jupiters. In this way, we may resume (after a two century interruption!) the tradition of planetary discoveries by amateur astronomers begun with William Herschel's 1787 discovery of the 'solar' planet Uranus. In the few years transitsearch has been in existence, investigators Tim Castellano (NASA Ames) and Greg Laughlin (UCSC) have written articles for Sky and Telescope and Astronomy magazines, have been featured in stories by the Reuters News Service, Nature magazine, Science magazine, Space.com, the American Institute of Physics and others and received several hundred thousand total hits on their website www.transitsearch,org.

Castellano, T.↗

The Astro-E2 Mission

The Astro-E2 observatory is a rebuild of the original Astro-E observatory that was lost during launch in February 2000. It is scheduled for launch into low earth orbit on a Japanese M-V rocket in early 2005. The Institute of Space and Astronautical Science, Japan Aerospace Exploration Agency, is developing the observatory with major contributions from the US. The three instruments on the observatory are the high-resolution x-ray spectrometer (the XRS) featuring a 30-pixel x-ray microcalorimeter array, a set of four CCD cameras (the XIS) and a combination photo-diode/scintillator detector system (the HXD) that will extend the band pass up to nearly 700 keV. A significant feature of Astro-E2 is that all of the instruments are coaligned and operated simultaneously. With its high spectral resolution and collecting area for spectroscopy above 1 keV, Astro-E2 should enable major discovery space and pioneer new technology for use in space. Prime areas for investigation are supernova remnants, active galaxies and the measurement of black hole properties via relativistically-broadened Fe-K emission galaxies. A number of enhancements have been made for the Astro-E2/XRS, including a higher resolution microcalorimeter array, ii mechanical cooler for longer cryogen life, and an improved in-flight calibration system. The Astro-E2/XIS has also been improved to include two back-side-illuminated CCDs to enhance the low energy response. Improvements have also been made to the x-ray mirrors used for both the XRS and XIS to sharpen the point spread function and reduce the effects of stray light. In this talk we will present the essential features of Astro-E2, paying particular attention to the enhancements, and describe the major scientific strengths of the observatory.

Kelley, Richard L.↗

Gel stretch method: a new method to measure constitutive properties of cardiac muscle cells

Diastolic dysfunction is an important cause of congestive heart failure; however, the basic mechanisms causing diastolic congestive heart failure are not fully understood, especially the role of the cardiac muscle cell, or cardiocyte, in this process. Before the role of the cardiocyte in this pathophysiology can be defined, methods for measuring cardiocyte constitutive properties must be developed and validated. Thus this study was designed to evaluate a new method to characterize cardiocyte constitutive properties, the gel stretch method. Cardiocytes were isolated enzymatically from normal feline hearts and embedded in a 2% agarose gel containing HEPES-Krebs buffer and laminin. This gel was cast in a shape that allowed it to be placed in a stretching device. The ends of the gel were held between a movable roller and fixed plates that acted as mandibles. Distance between the right and left mandibles was increased using a stepper motor system. The force applied to the gel was measured by a force transducer. The resultant cardiocyte strain was determined by imaging the cells with a microscope, capturing the images with a CCD camera, and measuring cardiocyte and sarcomere length changes. Cardiocyte stress was characterized with a finite-element method. These measurements of cardiocyte stress and strain were used to determine cardiocyte stiffness. Two variables affecting cardiocyte stiffness were measured, the passive elastic spring and viscous damping. The passive spring was assessed by increasing the force on the gel at 1 g/min, modeling the resultant stress vs. strain relationship as an exponential [sigma = A/k(ekepsilon - 1)]. In normal cardiocytes, A = 23.0 kN/m2 and k = 16. Viscous damping was assessed by examining the loop area between the stress vs. strain relationship during 1 g/min increases and decreases in force. Normal cardiocytes had a finite loop area = 1.39 kN/m2, indicating the presence of viscous damping. Thus the gel stretch method provided accurate measurements of cardiocyte constitutive properties. These measurements have allowed the first quantitative assessment of passive elastic spring properties and viscous damping in normal mammalian cardiocytes.

Non-NASA Center↗

Light microscopic image analysis system to quantify immunoreactive terminal area apposed to nerve cells

The present report describes a desktop computer-based method for the quantitative assessment of the area occupied by immunoreactive terminals in close apposition to nerve cells in relation to the perimeter of the cell soma. This method is based on Fast Fourier Transform (FFT) routines incorporated in NIH-Image public domain software. Pyramidal cells of layer V of the somatosensory cortex outlined by GABA immunolabeled terminals were chosen for our analysis. A Leitz Diaplan light microscope was employed for the visualization of the sections. A Sierra Scientific Model 4030 CCD camera was used to capture the images into a Macintosh Centris 650 computer. After preprocessing, filtering was performed on the power spectrum in the frequency domain produced by the FFT operation. An inverse FFT with filter procedure was employed to restore the images to the spatial domain. Pasting of the original image to the transformed one using a Boolean logic operation called 'AND'ing produced an image with the terminals enhanced. This procedure allowed the creation of a binary image using a well-defined threshold of 128. Thus, the terminal area appears in black against a white background. This methodology provides an objective means of measurement of area by counting the total number of pixels occupied by immunoreactive terminals in light microscopic sections in which the difficulties of labeling intensity, size, shape and numerical density of terminals are avoided.

Non-NASA Center↗

Non-GPS Geolocation for Space and Terrestrial Applications

Some near and far term space missions involve formation flying, which requires that the positions of multiple spacecraft be accurately known relative to a hub spacecraft. Many such missions will be located far outside the radius of the GPS constellation. So in such missions it will not be possible to derive position knowledge through the capabilities afforded by the GPS service. Consequently, in such missions, it is necessary to determine relative positions by other means. Depending on how well a position must be known, thus far it has appeared necessary to use means other than RF ranging, due to technical limitations. Once spacecraft have been crudely positioned using RF ranging, other tools such as star trackers, ccd cameras, and laser ranging are to be used for precise and accurate ranging. NASA Glenn is investigating an innovation in RF ranging that could be very useful for extending the capabilities of RF ranging in many circumstances. Currently, this innovation is a technical secret, but this paper will discuss the possibility of using RF triangulation for the purposes stated in its title, without disclosing any proprietary information. This paper includes a simulation that successfully illustrates how this technology could be used to perform vehicle tracking.

Robinson, Daryl C.↗

Time-Averaged Velocity, Temperature and Density Surveys of Supersonic Free Jets

A spectrally resolved molecular Rayleigh scattering technique was used to simultaneously measure axial component of velocity U, static temperature T, and density p in unheated free jets at Mach numbers M = 0.6,0.95, 1.4 and 1.8. The latter two conditions were achieved using contoured convergent-divergent nozzles. A narrow line-width continuous wave laser was passed through the jet plumes and molecular scattered light from a small region on the beam was collected and analyzed using a Fabry-Perot interferometer. The optical spectrum analysis air density at the probe volume was determined by monitoring the intensity variation of the scattered light using photo-multiplier tubes. The Fabry-Perot interferometer was operated in the imaging mode, whereby the fringe formed at the image plane was captured by a cooled CCD camera. Special attention was given to remove dust particles from the plume and to provide adequate vibration isolation to the optical components. The velocity profiles from various operating conditions were compared with that measured by a Pitot tube. An excellent comparison within 5m's demonstrated the maturity of the technique. Temperature was measured least accurately, within 10K, while density was measured within 1% uncertainty. The survey data consisted of centerline variations and radial profiles of time-averaged U, T and p. The static temperature and density values were used to determine static pressure variations inside the jet. The data provided a comparative study of jet growth rates with increasing Mach number. The current work is part of a data-base development project for Computational Fluid Dynamics and Aeroacoustics codes that endeavor to predict noise characteristics of high speed jets. A limited amount of far field noise spectra from the same jets are also presented. Finally, a direct experimental validation was obtained for the Crocco-Busemann equation which is commonly used to predict temperature and density profiles from known velocity profiles. Data presented in this paper are available in ASCII format upon request.

Panda, Jayanta↗

Irregular Satellites of the Planets

This proposal is directed towards the observational exploration of the irregular satellite systems of the planets. Primarily we use large-format CCD cameras on the world's largest telescopes, on Mauna Kea, to discover new irregular satellites and then to monitor their positions in order to ascertain their orbital characteristics. Separate observations are taken to determine the physical properties of the irregular satellites. The big picture science objective is to determine how these satellites were captures, and to use the properties of the satellites and their orbits to place constraints on early solar system (including formation) processes. Work in the first year has focussed on a major investigation of the Saturn irregular satellite system. We secured observing time on the Subaru and Gemini 8-m diameter telescopes in December 2004, January, February and March 2005 for the conduct of a deep, wide-area survey. This has resulted in the detection and orbit determination for 12 new satellites to be announced in the next week or two. Additional satellites were lost, temporarily, due to unusually poor weather conditions on Mauna Kea. These objects will be recovered and their orbits published next year. A separate survey of the Uranus irregular satellites was published (Sheppard, Jewitt and Kleyna 2005). Away from the telescope, we have discovered the amazing result that the four giant planets possess similar numbers of irregular satellites. This flies in the face of the standard gas-drag model for satellite capture, since only two of the giant planets are gas giants and the others (Uranus and Neptune) formed by a different process and in the absence of much gas. The constancy of the satellite number (each giant holds approximately 100 irregular satellites measured down to the kilometer scale) is either a coincidence, with different capture mechanisms at different planets giving by chance the same total numbers of irregular satellites, or indicates that the satellites were captured by a completely different process. We favor the latter (Jewitt and Sheppard 2005).

Jewitt, David↗

Fuzzy Logic Particle Tracking

A new all-electronic Particle Image Velocimetry technique that can efficiently map high speed gas flows has been developed in-house at the NASA Lewis Research Center. Particle Image Velocimetry is an optical technique for measuring the instantaneous two component velocity field across a planar region of a seeded flow field. A pulsed laser light sheet is used to illuminate the seed particles entrained in the flow field at two instances in time. One or more charged coupled device (CCD) cameras can be used to record the instantaneous positions of particles. Using the time between light sheet pulses and determining either the individual particle displacements or the average displacement of particles over a small subregion of the recorded image enables the calculation of the fluid velocity. Fuzzy logic minimizes the required operator intervention in identifying particles and computing velocity. Using two cameras that have the same view of the illumination plane yields two single exposure image frames. Two competing techniques that yield unambiguous velocity vector direction information have been widely used for reducing the single-exposure, multiple image frame data: (1) cross-correlation and (2) particle tracking. Correlation techniques yield averaged velocity estimates over subregions of the flow, whereas particle tracking techniques give individual particle velocity estimates. For the correlation technique, the correlation peak corresponding to the average displacement of particles across the subregion must be identified. Noise on the images and particle dropout result in misidentification of the true correlation peak. The subsequent velocity vector maps contain spurious vectors where the displacement peaks have been improperly identified. Typically these spurious vectors are replaced by a weighted average of the neighboring vectors, thereby decreasing the independence of the measurements. In this work, fuzzy logic techniques are used to determine the true correlation displacement peak even when it is not the maximum peak, hence maximizing the information recovery from the correlation operation, maintaining the number of independent measurements, and minimizing the number of spurious velocity vectors. Correlation peaks are correctly identified in both high and low seed density cases. The correlation velocity vector map can then be used as a guide for the particle-tracking operation. Again fuzzy logic techniques are used, this time to identify the correct particle image pairings between exposures to determine particle displacements, and thus the velocity. Combining these two techniques makes use of the higher spatial resolution available from the particle tracking. Particle tracking alone may not be possible in the high seed density images typically required for achieving good results from the correlation technique. This two-staged velocimetric technique can measure particle velocities with high spatial resolution over a broad range of seeding densities.

Source record↗

Stable Lobed Mixer With Combustion Demonstrated and Measured

The NASA Lewis Research Center collaborated with the Massachusetts Institute of Technology (MIT) on an experiment to study the use of lobed mixers to improve the fuel-air mixing process and increase combustion intensity in combustors with minimal pressure loss. This experiment is the first known stable combusting flow studied for this device, and the data show a much faster and much more uniform combustion process than for flat-plate mixers. Several potential benefits may be realized from this study in future combustors, including a reduction in NO_x emissions because of the more uniform temperature distribution. The experiment was done in Lewis' Planar Reacting Shear Layer facility, which was adapted to accept a lobed mixer in addition to the original planar tip. A graduate student at MIT provided the mixer design concept, and Lewis provided the engineering, operations, and research expertise. The experiment used hydrogen-nitrogen mixtures to react with vitiated hot air at 920 K. A flow speed of about 120 m/sec and a speed ratio of 0.5 were used. Flow diagnostics consisted of traversing fine-wire thermocouples and pitot probes for flow mapping. Supplementary fluorescence images were taken with a charged coupled device (CCD) camera to show the location and temporal behavior of the reaction zone. The data showed that the lobed mixer consumed the reactants between 3 to 10 times faster than a corresponding planar shear layer. The figure shows the dramatic difference in the measured temperature distribution with and without the lobed mixer. The increased mixing rate was due to a larger interfacial area as well as to the secondary flow from the streamwise vortices off the tips of the lobes. In addition, the fluorescence images showed that the lobes acted as flame stabilizers.

Source record↗

Stereo Imaging Velocimetry

Stereo imaging velocimetry (SIV) will permit the collection of quantitative, three-dimensional flow data from any optically transparent fluid that can be seeded with tracer particles. This includes such diverse experiments as the study of multiphase flow, bubble nucleation and migration, pool combustion, and crystal growth. This technique will be useful to the microgravity science community as our investigations of fluid behavior in reduced-gravity environments enhance our knowledge of heat transfer, surface tension, concentration-gradient-driven anomalies, and residual effects from g-jitter. In its proposed configuration, the NASA Lewis Research Center's Stereo Imaging Velocimeter will consist of at least two charged coupled device (CCD) cameras, oriented at some relative angle with respect to each other. The cameras will observe a fluid experiment that has been seeded with tracer particles that are neutrally buoyant to permit accurate flow tracking. Except for the tracer particles, this measurement technique will be nonintrusive. Velocity accuracies will be on the order of 1 to 5 percent of full field. Each camera will make a two-dimensional record of the motion of the seed particles in the observation volume. Three-dimensional data will be obtained by computationally combining the two-dimensional information.

Source record↗

Ultraviolet Molecular Rayleigh Scattering Used to Measure Velocity in High-Speed Flow

Molecular Rayleigh scattering offers a means to measure gas flow parameters including density, temperature, and velocity. No seeding of the flow is necessary. The Rayleigh scattered power is proportional to the gas density, the spectral width is related to the gas temperature, and the shift in the frequency of the spectral peak is proportional to one component of the fluid velocity. Velocity measurements based on Rayleigh scattering are more suitable for high-speed flow, where the bulk fluid velocity is on the order of, or larger than, the molecular thermal velocities. Use of ultraviolet wavelengths for Rayleigh scattering diagnostics is attractive for two reasons. First, the Rayleigh scattering cross section is proportional to the inverse 4th power of the wavelength. And second, the reflectivity of metallic surfaces is generally less than it is at longer wavelengths. This is of particular interest in confined flow situations, such as in small wind tunnels and aircraft engine components, where the stray laser light scattered from the windows and internal surfaces in the test facility limits the application of Rayleigh scattering diagnostics. In this work at the NASA Lewis Research Center, molecular Rayleigh scattering of the 266-nm fourth harmonic of a pulsed, injection seeded Nd:YAG (neodymium:yttriumaluminum- garnet) laser was used to measure velocity in a supersonic free air jet with a 9.3- mm exit diameter. The frequency of the Rayleigh scattered light was analyzed with a planar mirror Fabry-Perot interferometer used in a static imaging mode, with the images recorded on a cooled, high-quantum-efficiency charge-coupled discharge (CCD) camera. In addition, some unshifted light from the same laser pulse was imaged through the interferometer to generate a reference. Data were obtained with single laser pulses at velocities up to Mach 1.3. The measured velocities were in good agreement with velocities calculated from isentropic flow relations. Our conclusion from this study was that ultraviolet Rayleigh scattering is preferable in confined flow situations because of the increase in the ratio of Rayleigh scattering signal to stray laser light. On the other hand, in open flows, such as free jets and larger wind tunnels where stray laser light can be controlled, visible Rayleigh scattering is preferable.

Seasholtz, Richard G.↗

X-Ray Computed Tomography Monitors Damage in Composites

The NASA Lewis Research Center recently codeveloped a state-of-the-art x-ray CT facility (designated SMS SMARTSCAN model 100-112 CITA by Scientific Measurement Systems, Inc., Austin, Texas). This multipurpose, modularized, digital x-ray facility includes an imaging system for digital radiography, CT, and computed laminography. The system consists of a 160-kV microfocus x-ray source, a solid-state charge-coupled device (CCD) area detector, a five-axis object-positioning subassembly, and a Sun SPARCstation-based computer system that controls data acquisition and image processing. The x-ray source provides a beam spot size down to 3 microns. The area detector system consists of a 50- by 50- by 3-mm-thick terbium-doped glass fiber-optic scintillation screen, a right-angle mirror, and a scientific-grade, digital CCD camera with a resolution of 1000 by 1018 pixels and 10-bit digitization at ambient cooling. The digital output is recorded with a high-speed, 16-bit frame grabber that allows data to be binned. The detector can be configured to provide a small field-of-view, approximately 45 by 45 mm in cross section, or a larger field-of-view, approximately 60 by 60 mm in cross section. Whenever the highest spatial resolution is desired, the small field-of-view is used, and for larger samples with some reduction in spatial resolution, the larger field-of-view is used.

Baaklini, George Y.↗

Use of a Novel Rover-mounted Fluorescence Imager and Fluorescent Probes to Detect Biological Material in the Atacama Desert in Daylight

We have developed an imaging system, the Fluorescence Imager (FI), for detecting fluorescence signals from sparse microorganisms and biofilms during autonomous rover exploration. The fluorescence signals arise both from naturally occurring chromophores, such as chlorophyll of cyanobacteria and lichens, and from fluorescent probes applied to soil and rocks. Daylight imaging has been accomplished by a novel use of a high-powered flashlamp synchronized to a CCD camera. The fluorescent probes are cell permanent stains that have extremely low intrinsic fluorescence (quantum yields less than 0.01) and a large fluorescence enhancement (quantum yields greater than 0.4) when bound to the target. Each probe specifically targets either carbohydrates, proteins, nucleic acids or membrane lipids, the four classes of macromolecules found in terrestrial life. The intent of the probes is to interrogate the environment for surface and endolithic life forms.

Weinstein, S.↗

Optical Tweezer Assembly and Calibration

An Optical Tweezer, as the name implies, is a useful tool for precision manipulation of micro and nano scale objects. Using the principle of electromagnetic radiation pressure, an optical tweezer employs a tightly focused laser beam to trap and position objects of various shapes and sizes. These devices can trap micrometer and nanometer sized objects. An exciting possibility for optical tweezers is its future potential to manipulate and assemble micro and nano sized sensors. A typical optical tweezer makes use of the following components: laser, mirrors, lenses, a high quality microscope, stage, Charge Coupled Device (CCD) camera, TV monitor and Position Sensitive Detectors (PSDs). The laser wavelength employed is typically in the visible or infrared spectrum. The laser beam is directed via mirrors and lenses into the microscope. It is then tightly focused by a high magnification, high numerical aperture microscope objective into the sample slide, which is mounted on a translating stage. The sample slide contains a sealed, small volume of fluid that the objects are suspended in. The most common objects trapped by optical tweezers are dielectric spheres. When trapped, a sphere will literally snap into and center itself in the laser beam. The PSD s are mounted in such a way to receive the backscatter after the beam has passed through the trap. PSD s used with the Differential Interference Contrast (DIC) technique provide highly precise data. Most optical tweezers employ lasers with power levels ranging from 10 to 100 miliwatts. Typical forces exerted on trapped objects are in the pico-newton range. When PSDs are employed, object movement can be resolved on a nanometer scale in a time range of milliseconds. Such accuracy, however, can only by utilized by calibrating the optical tweezer. Fortunately, an optical tweezer can be modeled accurately as a simple spring. This allows Hook s Law to be used. My goal this summer at NASA Glenn Research Center is the assembly and calibration of an optical tweezer setup in the Instrumentation and Controls Division (5520). I am utilizing a custom LabVIEW Virtual Instrument program for data collection and microscope stage control. Helping me in my assignment are the following people: Mentor Susan Wrbanek (5520), Dr. Baha Jassemnejad (UCO) and Technicians Ken Weiland (7650) and James Williams (7650). Without their help, my task would not be possible.

Collins, Timothy M.↗