Search NASA⌕ Search

SEARCH · Search NASA

Results for “CITY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

Summary of Massachusetts Clean Energy Center's Workforce Needs Assessment for the City of Lawrence

In July 2023, the Massachusetts Clean Energy Center (MassCEC) published an employment report titled “Powering the Future: A Massachusetts Clean Energy Workforce Needs Assessment.” This report was intended to support the State in meeting its 2030 decarbonization goals by identifying both existing workforce and training resources as well as gaps and barriers that need to be addressed in order to scale the State’s workforce to meet future demand. The following is a summary of the content that is relevant to Lawrence, MA. This was completed as part of the US Department of Energy’s Communities LEAP (Local Energy Action Program) Pilot supporting the Lawrence Stakeholders Coalition (LSC) led by Browning the Green Space in partnership with Groundwork Lawrence, All In Energy, and the City of Lawrence.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

The Feasibility of Incorporating a 3D Velocity Model Into Earthquake Location Around Salt Lake City, UT Using a Physics Informed Neural Network

Earthquake location algorithms typically require travel time calculation. Doing this calculation in 3D, despite advances in algorithm efficiency and computational power, can still be prohibitively expensive in terms of resources and storage. Implementation of high-resolution 3D models in routine earthquake location would be a significant step forward in most of the world. Machine learning algorithms have potential to act as substitutes for travel time calculation algorithms or stored travel time tables. We investigate EikoNet - a physics informed neural network machine learning model that estimates travel times very quickly and comes with negligible memory-overhead. Specifically, we apply EikoNet to the Wasatch Fault Community Velocity Model (WFCVM), a highly detailed and complex 3D velocity model of the Salt Lake City, UT region. While routine locations in the area and studies of the 2020 Magna, UT earthquake sequence used a 1D velocity model, a 3D model may help better our understanding the structure of the major fault in the region. Our primary goal was to test the speed, memory requirements, and accuracy of EikoNet compared to a reference eikonal solver. We find that while the EikoNet is exceedingly fast and requires little memory overhead, achieving acceptable accuracy in estimated travel times is difficult and requires extensive computational resources.

58 GEOSCIENCES↗

Understanding Commercial Building Energy Use in the Greater New York City Area: Building Stock Segmentation for Retrofit Planning

This report is part of the second phase of a publication series focusing on approximately 100 different local geographies, or "clusters." Each report provides characteristic features and energy data for commercial buildings in a specific area to help policy makers at the city, county, and state level better understand building energy use and emissions. This report breaks down the energy consumption and emissions of the building stock in the counties shown in Figure 2 by building type, building size, end use, energy consumption, emissions, and segment.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Understanding Commercial Building Energy Use in Greater Kansas City: Building Stock Segmentation for Retrofit Planning

This report is part of the second phase of a publication series focusing on approximately 100 different local geographies, or "clusters." Each report provides characteristic features and energy data for commercial buildings in a specific area to help policy makers at the city, county, and state level better understand building energy use and emissions. This report breaks down the energy consumption and emissions of the building stock in the counties shown in Figure 2 by building type, building size, end use, energy consumption, emissions, and segment.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Clean Cities and Communities Partnership 2023 Activity Report

This is the 2023 report for the Clean Cities and Communities (CC&C) partnership. It tracks the metrics that have been reported by individual coalitions and aggregated to the national level. It looks at the various outreach activities, grant activities, and implementation of clean transportation technologies. Such technologies include natural gas vehicles, electric vehicles, propane vehicles, hydrogen fuel cell vehicles, biodiesel, ethanol, idle reduction technologies, fuel economy improvement technologies, vehicle-miles-traveled reduction technologies, and off-road technologies. The CC&C partnership had an energy use impact of over 1 billion gallons in 2023 and reduced emissions by nine million tons. Outreach, engagement, and training activities increased 18% from last year.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Understanding Commercial Building Energy Use in the Greater Columbia-Fayetteville-Jefferson City-Joplin-Springfield-Wichita Areas: Building Stock Segmentation for Retrofit Planning

This report is part of the second phase of a publication series focusing on approximately 100 different local geographies, or "clusters." Each report provides characteristic features and energy data for commercial buildings in a specific area to help policy makers at the city, county, and state level better understand building energy use and emissions. This report breaks down the energy consumption and emissions of the building stock in the counties shown in Figure 2 by building type, building size, end use, energy consumption, emissions, and segment.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Benchmark Calculation for the Quad Cities Unit 1 Cycles 1-3 Using the SCALE 6.3/Polaris–PARCS v3.4.2 Code Package

In this study, benchmark calculations were performed for the Quad Cities Unit 1 cycles 1–3 to validate the SCALE 6.3/Polaris–PARCS v3.4.2 code package with the ENDF/B-VII.1 AMPX 56-group library by comparing the simulated results with the measured data. The benchmark results will be used in evaluating uncertainties of the SCALE/Polaris–PARCS code package for boiling water reactor physics analysis for key nuclear parameters such as reactivity and assembly power peaking factors. This report details plant and fuel design specifications and input data for SCALE/Polaris, GenPMAXS, and PARCS; additionally, detailed information is provided for all the input and output files produced for the benchmark calculations. The benchmark results are summarized herein so that they can be used to evaluate uncertainties with other benchmark results for key nuclear parameters.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Understanding Multifamily Energy Use in Carson City, Storey, and Washoe County: Building Stock Segmentation for Retrofit Planning

This report is an addendum to a publication series that focuses on approximately 100 different local geographies, or "clusters". This addendum expands the report series to include large multifamily building characteristics as well as energy and emission data for each local geography. The intention of this addendum is to help policymakers at the city, county, and state levels better understand building energy use and emissions in large multifamily buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Understanding Multifamily Energy Use in the Greater Columbia-Fayetteville-Jefferson City-Joplin-Springfield-Wichita Areas: Building Stock Segmentation for Retrofit Planning

This report is an addendum to a publication series that focuses on approximately 100 different local geographies, or "clusters". This addendum expands the report series to include large multifamily building characteristics as well as energy and emission data for each local geography. The intention of this addendum is to help policymakers at the city, county, and state levels better understand building energy use and emissions in large multifamily buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Understanding Multifamily Energy Use in the Greater New York City Area: Building Stock Segmentation for Retrofit Planning

This report is an addendum to a publication series that focuses on approximately 100 different local geographies, or "clusters". This addendum expands the report series to include large multifamily building characteristics as well as energy and emission data for each local geography. The intention of this addendum is to help policymakers at the city, county, and state levels better understand building energy use and emissions in large multifamily buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Understanding Multifamily Energy Use in Greater Kansas City: Building Stock Segmentation for Retrofit Planning

This report is an addendum to a publication series that focuses on approximately 100 different local geographies, or "clusters". This addendum expands the report series to include large multifamily building characteristics as well as energy and emission data for each local geography. The intention of this addendum is to help policymakers at the city, county, and state levels better understand building energy use and emissions in large multifamily buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Catalyst-Based Nonchemical Water Treatment System Frank E. Moss US Courthouse Salt Lake City, Utah

In 2012 and 2013, the US General Services Administration (GSA) and Oak Ridge National Laboratory conducted an evaluation of a novel nonchemical water treatment (NCWT) system at the Frank E. Moss US Courthouse in Salt Lake City, Utah. This system purports to use a proprietary metallic catalyst to change the water’s chemistry such that hard calcite does not form on surfaces that are in contact with the water. The catalyst-based NCWT system was installed on an electric domestic water heater in the courthouse. 1 This water heater had been experiencing severe calcite buildup on the heating elements. The calcite buildup impeded heat transfer from the heating elements into the domestic water, leading to the thermostat being set excessively high in an attempt to maintain the water temperature. This caused excess heat to build up on the elements, resulting in their premature failure which required frequent replacement. The buildup also required the elements to stay energized constantly to produce enough heat to maintain temperature in the domestic hot water system. After installing the catalyst-based NCWT system, calcite buildup was dramatically reduced and failure of the elements ceased. Labor and material savings from not having to replace the elements ($\$$1,060/year) allow for less than a two-year simple payback when compared to the installed cost of the system ($\$$1,692) plus minimal annual maintenance ($\$$100/year). The catalyst-based NCWT system should be considered for deployment in any heating system that is subject to calcification, including hydronic heating systems and boilers, condensing boilers, gas water heaters, and electric water heaters. Had the catalyst-based NCWT technology not been installed on the water heater, a conventional salt-based calcite prevention system would have provided the same prevention of calcite buildup. The budget installed cost of such a system would have been $\$$3,200 plus $\$$350/year in chemicals and $\$$1,500/year labor to service the chemicals. Comparing the conventional to the catalyst-based system, the latter has both a lower installed cost and annual operating cost. The original test plan was to install the technology on both the domestic water heating system and on the site’s cooling tower, which had faced calcite issues in its history. This tower has had a calcite buildup problem that is currently being addressed with a salt-based treatment system. The project’s timeline did not allow for installing a system and testing it on the tower during the initial phase of this project in 2012 and 2013. A preliminary economic analysis was performed to estimate the installed cost and potential savings on the cooling tower. If installed on the site’s cooling tower, the installed cost of the catalyst-based system would be more expensive than the salt-based system ($\$$32,380 vs. $\$$2,700 for the salt-based). However, the salt-based system requires $\$$900/year in chemicals and $\$$3,900/year in labor, neither of which is needed by the catalyst based system. This would give a simple payback of less than seven years using the technology on a cooling tower.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Gateway Cities Unplugged: (em)Powering Affordable Housing (Final Technical Report)

The Gateway Cities Unplugged: (em)Powering Affordable Housing (the “Project”) was launched to address a critical challenge in the U.S. building and energy sectors: enabling multifamily buildings especially those serving low and moderate‑income (LMI) communities to actively support grid modernization through Grid‑Interactive Efficient Buildings (GEB). Multifamily housing represents a large share of national building energy consumption, yet the sector faces persistent barriers to adopting advanced load flexibility technologies, including capital constraints, aging infrastructure, and limited access to demand‑side management tools. This Project sought to overcome those barriers by defining, evaluating, and designing commercially viable GEB technology packages for six representative multifamily properties across Massachusetts, Connecticut, and New York.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Sodar - Colorado City, TX - Processed Data

This dataset was produced from the raw sodar .txt files from the Colorado City, TX site during the WFIP1 campaign. Quality control and formatting have been applied to transform the numerous raw files into a single file to provide user friendliness and improved wind resource characterization at this location.

17 WIND ENERGY↗

Source Analysis of Ozone Pollution in Liaoyuan City’s Atmosphere Based on Machine Learning Models and HYSPLIT Clustering Method

Firstly, this study investigates the spatiotemporal distribution characteristics of the ozone (O 3 ) pollution in Liaoyuan City using monitoring data from 2015 to 2024. Then, three machine learning models (ML)—random forest (RF), support vector machine (SVM), and artificial neural network (ANN)—are employed to quantify the influence of meteorological and non-meteorological factors on O 3 concentrations. Finally, the HYSPLIT clustering method and CMAQ model are utilized to analyze inter-regional transport characteristics, identifying the causes of O 3 pollution. The results indicate that O 3 pollution in Liaoyuan exhibits a distinct seasonal pattern, with the highest concentrations found in spring and summer, peaking in the afternoon. Among the three ML models, the random forest model demonstrates the best predictive performance (R 2 = 0.9043). Feature importance identifies NO 2 as the primary driving factor, followed by meteorological conditions in the second quarter and land surface characteristics. Furthermore, regional transport significantly contributes to O 3 pollution, with approximately 80% of air mass trajectories in heavily polluted episodes originating from adjacent industrial areas and the sea. The combined effects of transboundary precursors and O 3 transport with local emissions and meteorological conditions further increase the O 3 pollution level. This study highlights the need to strengthen coordinated NO X and VOCs emission reductions and enhance regional joint prevention and control strategies in China.

HYSPLIT clustering↗

SARS-CoV-2 Omicron (B.1.1.529) Infection of Wild White-Tailed Deer in New York City

There is mounting evidence of SARS-CoV-2 spillover from humans into many domestic, companion, and wild animal species. Research indicates that humans have infected white-tailed deer, and that deer-to-deer transmission has occurred, indicating that deer could be a wildlife reservoir and a source of novel SARS-CoV-2 variants. We examined the hypothesis that the Omicron variant is actively and asymptomatically infecting the free-ranging deer of New York City. Between December 2021 and February 2022, 155 deer on Staten Island, New York, were anesthetized and examined for gross abnormalities and illnesses. Paired nasopharyngeal swabs and blood samples were collected and analyzed for the presence of SARS-CoV-2 RNA and antibodies. Of 135 serum samples, 19 (14.1%) indicated SARS-CoV-2 exposure, and 11 reacted most strongly to the wild-type B.1 lineage. Of the 71 swabs, 8 were positive for SARS-CoV-2 RNA (4 Omicron and 4 Delta). Two of the animals had active infections and robust neutralizing antibodies, revealing evidence of reinfection or early seroconversion in deer. Variants of concern continue to circulate among and may reinfect US deer populations, and establish enzootic transmission cycles in the wild: this warrants a coordinated One Health response, to proactively surveil, identify, and curtail variants of concern before they can spill back into humans.

60 APPLIED LIFE SCIENCES↗

Simulated Fuel Economy and Emissions Performance during City and Interstate Driving for a Heavy-Duty Hybrid Truck

We compare simulated fuel economy and emissions for both conventional and hybrid class 8 heavy-duty diesel trucks operating over multiple urban and highway driving cycles. Both light and heavy freight loads were considered, and all simulations included full aftertreatment for NOx and particulate emissions controls. The aftertreatment components included a diesel oxidation catalyst (DOC), urea-selective catalytic NOx reduction (SCR), and a catalyzed diesel particulate filter (DPF). Our simulated hybrid powertrain was configured with a pre-transmission parallel drive, with a single electric motor between the clutch and gearbox. A conventional HD truck with equivalent diesel engine and aftertreatment was also simulated for comparison. Our results indicate that hybridization can significantly increase HD fuel economy and improve emissions control in city driving. However, there is less potential hybridization benefit for HD highway driving. A major factor behind the reduced hybridization benefit for highway driving is that there are fewer opportunities to utilize regenerative breaking. Our aftertreatment simulations indicate that opportunities for passive DPF regeneration are much greater for both hybrid and conventional trucks during highway driving due to higher sustained exhaust temperatures. When passive DPF regeneration is extensively utilized, the fuel penalty for particulate control is virtually eliminated, except for the 0.4%-0.9% fuel penalty associated with the slightly higher exhaust backpressure.

Daw, C. Stuart↗