Performance study of GPUs in real-time trigger applications for HEP experiments

Graphical Processing Units (GPUs) have evolved into highly parallel, multi-threaded, multicore powerful processors with high memory bandwidth. GPUs are used in a variety of intensive computing applications. The combination of highly parallel architecture and high memory bandwidth makes GPUs a potentially promising technology for effective real-time processing for High Energy Physics (HEP) experiments. However, not much is known of their performance in real-time applications that require low latency, such as the trigger for HEP experiments. We describe an R and D project with the goal to study the performance of GPU technology for possible low latency applications, performing basic operations as well as some more advanced HEP lower-level trigger algorithms (such as fast tracking or jet finding). We present some preliminary results on timing measurements, comparing the performance of a CPU versus a GPU with NVIDIA's CUDA general-purpose parallel computing architecture, carried out at CDF's Level-2 trigger test stand. These studies will provide performance benchmarks for future studies to investigate the potential and limitations of GPUs for real-time applications in HEP experiments.

43 PARTICLE ACCELERATORS↗

The 3SPACE digitizer: A new input device for solid geometry modeling

The 3SPACE Digitizer is a derivation of SPASYN, which is a patented magnetic transducing system offering an accurate method of calculating the location of one object relative to another. SPASYN uses low-frequency magnetic fields to measure both the position and orientation of its sensor relative to its transmitter. The 3SPACE Digitizer unit consists of a system's electronics unit, a model table, a stylus, and a keypad. In operation, the 3SPACE Digitizer determines the X, Y, Z coordinates of any point located on a low-conductive, three-dimensional model. This data, along with the orientation of the Digitizer's stylus, is immediately available for transmission to a host computer or graphics terminal. Digitization is effected by touching the point to be measured with the tip of a handheld stylus. The 3SPACE Digitizer presents new opportunities for interacting with computers in a large number of engineering and scientific applications. Developed from proven military technology, the 3SPACE Digitizer significantly simplifies three-dimensional digitization and overcomes many of the problems that once plagued such procedures. Its ability to digitize solid objects makes it a valuable new tool for computer-aided design and manufacturing.

Scully, J.↗

Steady-State Calibration of a Diesel Engine in Computational Fluid Dynamics Using a Graphical Processing Unit-Based Chemistry Solver

The prospect of analysis-driven precalibration of a modern diesel engine is extremely valuable in order to significantly reduce hardware investments and accelerate engine designs compliant with stricter fuel economy regulations. Advanced modeling tools, such as CFD, are often used with the goal of streamlining significant portions of the calibration process. The success of the methodology largely relies on the accuracy of analytical predictions, especially engine-out emissions. However, the effectiveness of CFD simulation tools for in-cylinder engine combustion is often compromised by the complexity, accuracy, and computational overhead of detailed chemical kinetics necessary for combustion calculations. The standard approach has been to use skeletal kinetic mechanisms (~50 species), which consume acceptable computational time but with degraded accuracy. In this work, a comprehensive demonstration and validation of the analytical precalibration process is presented for a passenger car diesel engine using CFD simulations and a graphical processing unit (GPU)-based chemical kinetics solver (Zero-RK, developed at Lawrence Livermore National Laboratory, Livermore, CA) on high performance computing resources to enable the use of detailed kinetic mechanisms. Diesel engine combustion computations have been conducted over 600 operating points spanning in-vehicle speed-load map, using massively parallel ensemble simulation sets on the Titan supercomputer located at the Oak Ridge Leadership Computing Facility. The results with different mesh resolutions have been analyzed to compare differences in combustion and emissions (NOx, carbon monoxide CO, unburned hydrocarbons (UHC), and smoke) with actual engine measurements. The results show improved agreement in combustion and NOx predictions with a large n-heptane mechanism consisting of 144 species and 900 reactions with refined mesh resolution; however, agreement in CO, UHC, and smoke remains a challenge.

42 ENGINEERING↗

Graphical Planning Of Spacecraft Missions

Mission Planning Graphical Tool (MPGT) computer program provides analysts with graphical representations of spacecraft and environmental data used in planning missions. Designed to be generic software tool configured to analyze any specified Earth-orbiting spacecraft mission. Data presented as series of overlays on top of two-dimensional or three-dimensional projection of Earth. Includes spacecraft-orbit tracks, ground-station-antenna masks, solar and lunar ephemerides, and coverage by Tracking Data and Relay Satellite System (TDRSS). From graphical representations, analyst determines such spacecraft-related constraints as communication coverage, infringement upon zones of interference, availability of sunlight, and visibility of targets to instruments.

Jeletic, J. F.↗

TOMS FM-2 Calibration Report

The radiance and irradiance sensitivities of the TOMS are tabulated in table 1. The results obtained with FEL standard F-281 are actual while those computed for lamps F-239 and F-207 are for reference purposes as those standards were out of calibration at the time of use. The irradiance results were computed for the serial number 5 carousel surfaces, the flight unit, and the serial number 4 carousel surfaces, the flight backup unit. The data and results are presented tabularly and graphically. The computed instrument sensitivities based on the radiance results are higher than those resulting from the irradiance data (see figure's 9 a,b,&c). No quantitative explanation for this difference has been determined. The radiance data was obtained with the instrument in the NADIR detent while the irradiance data was obtained with the scan mirror rotated 90 degrees from NADIR to view the diffuser. The sensitivity plots show the pronounce effects of the instruments measured spectral bandwidth used in the computations. The radiance data, figures 5 a,b & c, are quite smooth. Sources of error in the calibrations include the normalized radiance, source lamp irradiance , diffuser BRDF, and geometry factors. These are discussed in the errors of calibration section included in this report.

Source record↗

Radiation View-Factor Program With Interactive Graphics

VIEW is six computer programs for determining view factors, graphically displaying surfaces, and evaluating solar irradiation of assemblage of surfaces. Programs offer thermal engineer powerful system for view-factor determination. Central program of system (VIEWC) computes longwave radiantenergy exchange factors between surfaces that make up enclosure. Other VIEW programs support user working with VIEWC.

Emery, A. F.↗

Validation of GPUMCD for low-energy brachytherapy seed dosimetry

Purpose: To validate GPUMCD, a new package for fast Monte Carlo dose calculations based on the GPU (graphics processing unit), as a tool for low-energy single seed brachytherapy dosimetry for specific seed models. As the currently accepted method of dose calculation in low-energy brachytherapy computations relies on severe approximations, a Monte Carlo based approach would result in more accurate dose calculations, taking in to consideration the patient anatomy as well as interseed attenuation. The first step is to evaluate the capability of GPUMCD to reproduce low-energy, single source, brachytherapy calculations which could ultimately result in fast and accurate, Monte Carlo based, brachytherapy dose calculations for routine planning. Methods: A mixed geometry engine was integrated to GPUMCD capable of handling parametric as well as voxelized geometries. In order to evaluate GPUMCD for brachytherapy calculations, several dosimetry parameters were computed and compared to values found in the literature. These parameters, defined by the AAPM Task-Group No. 43, are the radial dose function, the 2D anisotropy function, and the dose rate constant. These three parameters were computed for two different brachytherapy sources: the Amersham OncoSeed 6711 and the Imagyn IsoStar IS-12501. Results: GPUMCD was shown to yield dosimetric parameters similar to those found in the literature. It reproduces radial dose functions to within 1.25% for both sources in the 0.5< r <10 cm range. The 2D anisotropy function was found to be within 3% at r = 5 cm and within 4% at r = 1 cm. The dose rate constants obtained were within the range of other values reported in the literature.Conclusion: GPUMCD was shown to be able to reproduce various TG-43 parameters for two different low-energy brachytherapy sources found in the literature. The next step is to test GPUMCD as a fast clinical Monte Carlo brachytherapy dose calculations with multiple seeds and patient geometry, potentially providing more accurate results than the TG-43 formalism while being much faster than calculations using general purpose Monte Carlo codes.

61 RADIATION PROTECTION AND DOSIMETRY↗

What Makes an Icon Effective?

Several criteria like conspicuity, legibility, and comprehension must be met for an icon to be effective. Previous studies found that visual and cognitive features of icons have significant influence on meeting the criteria for icon effectiveness. The aim of this paper is to present a review on visual features (color, shape, size) and cognitive features (familiarity, concreteness, complexity, meaningfulness, semantic distance). The influence of these features on icon effectiveness was studied. The relationships amongst cognitive features and ways to quantify cognitive features were identified. Suggestions regarding opportunities for future research on icons were also highlighted. Such a review would be helpful in formulating research plans and methodologies for icon studies in the future. In addition, this review would facilitate graphic designers to create more user-friendly icons in various contexts.

97 MATHEMATICS AND COMPUTING↗

The effects of a dynamic graphical model during simulation-based training of console operation skill

LOADER is a Windows-based simulation of a complex procedural task. The task requires subjects to execute long sequences of console-operation actions (e.g., button presses, switch actuations, dial rotations) to accomplish specific goals. The LOADER interface is a graphical computer-simulated console which controls railroad cars, tracks, and cranes in a fictitious railroad yard. We hypothesized that acquisition of LOADER performance skill would be supported by the representation of a dynamic graphical model linking console actions to goal and goal states in the 'railroad yard'. Twenty-nine subjects were randomly assigned to one of two treatments (i.e., dynamic model or no model). During training, both groups received identical text-based instruction in an instructional-window above the LOADER interface. One group, however, additionally saw a dynamic version of the bird's-eye view of the railroad yard. After training, both groups were tested under identical conditions. They were asked to perform the complete procedure without guidance and without access to either type of railroad yard representation. Results indicate that rather than becoming dependent on the animated rail yard model, subjects in the dynamic model condition apparently internalized the model, as evidenced by their performance after the model was removed.

Farquhar, John D.↗

Review of Teleoperator Research

A predictor display to overcome time lag problems with remote control systems is discussed. The video picture is a (necessarily) time-delayed picture from the remote location, generated as a coherent frame (snapshot) so that all picture elements in a single scan are delayed the same. The computer-generated graphics is a line drawing of the present configuration of the manipulator arm, vehicle or other device. The latter is generated by using the same control signals which are sent to the remote manipulator (device) to drive a computer model of it. The computer model is drawn on the video display in exactly the same location as where it will actually be after a one-way time delay and where it will be seen to be on the video after one round-trip time delay. If one waits at least one round-trip delay without moving, both the graphics model and the video picture of the manipulator (device) are seen to coincide. The predictor technque proved to work well and was shown for time delays in the 1-3 second range to reduce completion times for a variety of manipulation tasks by 50-150 percent reliably.

Sheridan, T. B.↗

Detection And Mapping (DAM) package. Volume 4B: Software System Manual, part 2

Computer programs, graphic devices, and an integrated set of manual procedures designed for efficient production of precisely registered and formatted maps from digital data are presented. The software can be used on any Univac 1100 series computer. The software includes pre-defined spectral limits for use in classifying and mapping surface water for LANDSAT-1, LANDSAT-2, and LANDSAT-3.

Schlosser, E. H.↗

A modernized PDL approach for Ada software development

The desire to integrate newly available, graphically-oriented Computed Aided Software Engineering (CASE) tools with existing software design approaches is changing the way Program Design Language (PDL) or Process Description Language is used for large system development. In the approach documented here, Software Engineers use graphics tools to model the problem and to describe high level software design in diagrams. An Ada-based PDL is used to document low level design. Some results are provided along with an analysis for each of three smaller General Electric (GE) Ada development projects that utilized variations on this approach. Finally some considerations are identified for larger scale implementation.

Usavage, Paul, Jr.↗

Computationally efficient Bayesian estimation of graphical networks for omics data

Graphical networks are useful, widely-used modeling approaches to represent complex biological processes with biological measurements generated by platforms such as mass spectrometry. Bayesian analyses of graphical networks for omics data have several advantages over their frequentist counterparts, such as the inclusion of prior knowledge in the estimation of models. However, Bayesian approaches to date have only been feasible for data with a couple hundred biomolecules due to prohibitive computational time, but omics data often contains tens of thousands of biomolecules. Here, we present and illustrate a more computationally efficient approach named BPlane (Bayesian PseudoLikelihood-based Algorithm for Network Estimation) to extend Bayesian modeling capabilities for larger-sized datasets, such as most untargeted proteomics data. Via simulation, we demonstrate that BPlane produces substantial computational savings over a current state-of-the-art Bayesian algorithm while maintaining competitive edge detection accuracy. On a SARS-CoV2 proteomics data with 7000 proteins, the competing algorithm takes three times as long to complete the first iteration as BPlane takes to converge after over 100 iterations.

EM algorithm↗

Window-Based Graphics For Scheduling

XOPPS computer program generates window-based graphics for scheduling and planning projects. Provides easy and fast on-screen "what-you-see-is-what-you-get" editing capabilities. Object-oriented, but unique in its capability for creating objects that have date attributes. Can be used in conjunction with project-management software. Written in C language for Sunseries workstations running SunOS. XOPPS was developed in 1992, based on the Sunview version of OPPS (NPO-18439) developed in 1990. It is copyrighted work with all copyright vested in NASA.

Mulnix, Cassie↗

A prototype expert/information system for examining environmental risks of KSC activities

Protection of the environment and natural resources at the Kennedy Space Center (KSC) is of great concern. An expert/information system to replace the paper-based KSC Environmental Checklist was developed. The computer-based system requests information only as a required and supplies assistance as needed. The most comprehensive portion of the system provides information about endangered species habitat at KSC. This module uses geographic information system (GIS) data and tools, expert rules, color graphics, computer-based video, and hypertext to provide information.

Engel, Bernard A.↗

Software For Diagnosis Of Parallel Processing

Ames Instrumentation System (AIMS) computer program package of software tools measuring and analyzing performances of parallel-processing application programs. Helps programmer to debug and refine, and to monitor and visualize execution of, parallel-processing application software for Intel iPSC/860 (or equivalent) multicomputer. Performance data collected displayed graphically on computer workstations supporting X-Windows.

Hontalas, Philip↗

Dynamic analysis of astronaut motions in microgravity: Applications for Extravehicular Activity (EVA)

Simulations of astronaut motions during extravehicular activity (EVA) tasks were performed using computational multibody dynamics methods. The application of computational dynamic simulation to EVA was prompted by the realization that physical microgravity simulators have inherent limitations: viscosity in neutral buoyancy tanks; friction in air bearing floors; short duration for parabolic aircraft; and inertia and friction in suspension mechanisms. These limitations can mask critical dynamic effects that later cause problems during actual EVA's performed in space. Methods of formulating dynamic equations of motion for multibody systems are discussed with emphasis on Kane's method, which forms the basis of the simulations presented herein. Formulation of the equations of motion for a two degree of freedom arm is presented as an explicit example. The four basic steps in creating the computational simulations were: system description, in which the geometry, mass properties, and interconnection of system bodies are input to the computer; equation formulation based on the system description; inverse kinematics, in which the angles, velocities, and accelerations of joints are calculated for prescribed motion of the endpoint (hand) of the arm; and inverse dynamics, in which joint torques are calculated for a prescribed motion. A graphical animation and data plotting program, EVADS (EVA Dynamics Simulation), was developed and used to analyze the results of the simulations that were performed on a Silicon Graphics Indigo2 computer. EVA tasks involving manipulation of the Spartan 204 free flying astronomy payload, as performed during Space Shuttle mission STS-63 (February 1995), served as the subject for two dynamic simulations. An EVA crewmember was modeled as a seven segment system with an eighth segment representing the massive payload attached to the hand. For both simulations, the initial configuration of the lower body (trunk, upper leg, and lower leg) was a neutral microgravity posture. In the first simulation, the payload was manipulated around a circular trajectory of 0.15 m radius in 10 seconds. It was found that the wrist joint theoretically exceeded its ulnal deviation limit by as much as 49. 8 deg and was required to exert torques as high as 26 N-m to accomplish the task, well in excess of the wrist physiological limit of 12 N-m. The largest torque in the first simulation, 52 N-m, occurred in the ankle joint. To avoid these problems, the second simulation placed the arm in a more comfortable initial position and the radius and speed of the circular trajectory were reduced by half. As a result, the joint angles and torques were reduced to values well within their physiological limits. In particular, the maximum wrist torque for the second simulation was only 3 N-m and the maximum ankle torque was only 6 N-m.