Search NASA⌕ Search

SEARCH · Search NASA

Results for “Capture”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

Durable and Versatile Immobilized Carbonic Anhydrase on Textile Structured Packing for CO 2 Capture

High-performance carbon dioxide (CO 2 )-capture technologies with low environmental impact are necessary to combat the current climate change crisis. Durable and versatile “drop-in-ready” textile structured packings with covalently immobilized carbonic anhydrase (CA) were created as efficient, easy to handle catalysts for CO 2 absorption in benign solvents. The hydrophilic textile structure itself contributed high surface area and superior liquid transport properties to promote gas-liquid reactions that were further enhanced by the presence of CA, leading to excellent CO 2 absorption efficiencies in lab-scale tests. Mechanistic investigations revealed that CO 2 capture efficiency depended primarily on immobilized enzymes at or near the surface, whereas polymer entrapped enzymes were more protected from external stressors than those exposed at the surface, providing strategies to optimize performance and durability. Textile packing with covalently attached enzyme aggregates retained 100% of the initial 66.7% CO 2 capture efficiency over 71-day longevity testing and retained 85% of the initial capture efficiency after 1-year of ambient dry storage. Subsequent stable performance in a 500 h continuous liquid flow scrubber test emphasized the material robustness. Biocatalytic textile packings performed well with different desirable solvents and across wide CO 2 concentration ranges that are critical for CO 2 capture from coal and natural gas-fired power plants, from natural gas and biogas for fuel upgrading, and directly from air.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Dynamics of Asteroid 2006 RH120: Pre-Capture and Escape Phases

Asteroid 2006 RH120 was the first natural object captured by the Earth to be observed called a Minimoon. In this work, we show that the invariant manifolds of the orbits around the L1 and L2 Lagrange points play a significant role in the capture of the asteroid around Earth and its eventual escape from the Earth approximately 1 year later. This is similar to the Temporary Capture of comets around Jupiter. We determined that the asteroid was in a 27:29 mean motion resonance with the Earth and approached the Earth through the stable manifold of an L1 Northern Halo Orbit. After the Temporary Capture, the asteroid escaped the Earth through the unstable manifold of an L2 Southern Halo orbit and into a 21:20 resonant orbit with the Earth. The asteroid travelled through a series of resonant orbits before and after the capture. These resonant transitions are similar to the orbits of Galileo and Cassini during their touring phase, using resonant orbits to reduce mission ∆V requirements.

NEO↗

COMBUSTION-ASSISTED CO2 CAPTURE USING MECC MEMBRANES

Mixed Electron and Carbonate ion Conductor (MECC) membranes have been proposed as a means to separate CO{sub 2} from power plant flue gas. Here a modified MECC CO{sub 2} capture process is analyzed that supplements retentate pressurization and permeate evacuation as a means to create a CO{sub 2} driving force with a process assisted by the catalytic combustion of syngas on the permeate side of the membrane. The combustion reactions consume transported oxygen, making it unavailable for the backwards transport reaction. With this change, the MECC capture system becomes exothermic, and steam for electricity production may be generated from the waste heat. Greater than 90% of the CO{sub 2} in the flue gas may be captured, and a compressed CO{sub 2} product stream is produced. A fossil-fueled power plant using this process would consume 14% more fuel per unit electricity produced than a power plant with no CO{sub 2} capture system, and has the potential to meet U.S. DOE's goal that deployment of a CO{sub 2} capture system at a fossil-fueled power plant should not increase the cost of electricity from the combined facility by more than 30%.

20 FOSSIL-FUELED POWER PLANTS↗

Control system design for maintaining CO{sub 2} capture in IGCC power plants while loading-following

Load-following requirements for future integrated gasification combined cycle (IGCC) power plants with precombustion CO{sub 2} capture are expected to be far more challenging as electricity produced by renewable energy is connected to the grid and strict environmental limits become mandatory requirements. In this work, loadfollowing studies are performed using a comprehensive dynamic model of an IGCC plant with pre-combustion CO{sub 2} capture developed in Aspen Engineering Suite (AES). Considering multiple single-loop controllers for power demand load following, the preferred IGCC control strategy from the perspective of a power producer is gas turbine (GT) lead with gasifier follow. In this strategy, the GT controls the load by manipulating its firing rate while the slurry feed flow to the gasifier is manipulated to control the syngas pressure at the GT inlet. The syngas pressure control is an integrating process with significant time delay mainly because of the large piping and equipment volumes between the gasifier and the GT inlet. A modified proportional–integral–derivative (PID) control is considered for IGCC syngas pressure control. The desired CO{sub 2} capture rate must be maintained while the IGCC plant follows the load. For maintaining the desired CO{sub 2} capture rate, the control performance of PID control is compared with linear model predictive control (LMPC). The results show that the LMPC outperforms PID control for maintaining CO{sub 2} capture rates in an IGCC power plant while load following.

20 FOSSIL-FUELED POWER PLANTS↗

Evaluation of Cryogenic Systems for Post Combustion CO2 Capture

Cryogenic capture of carbon dioxide from flue gas streams is one potential pathway to reduce the CO2 emissions from power plants and industrial sources. In this paper, a minimum energy analysis of idealized cryogenic carbon capture processes is performed. Parametric studies on this idealized process are quantified to study the effect of minimum capture temperature and simulated heat exchange approach temperatures. The theoretical and practical difficulties in approaching this ideal process are described and discussed. Finally, the Sustainable Energy Solutions External Cooling Loop Cryogenic Carbon Capture™ process is evaluated and compared to the idealized carbon-capture process.

20 FOSSIL-FUELED POWER PLANTS↗

Analysis of bipolar membranes for electrochemical CO 2 capture from air and oceanwater

Carbon dioxide (CO 2 ) must be removed from the atmosphere to mitigate the negative effects of climate change. However, the most scalable methods for removing CO 2 from the air require heat from fossil-fuel combustion to produce pure CO 2 and continuously regenerate the sorbent. Bipolar-membrane electrodialysis (BPM-ED) is a promising technology that uses renewable electricity to dissociate water into acid and base to regenerate bicarbonate-based CO 2 capture solutions, such as those used in chemical loops of direct-air-capture (DAC) processes, and in direct-ocean capture (DOC) to promote atmospheric CO 2 drawdown via decarbonization of the shallow ocean. In this study, we develop an experimentally validated 1D model for the electrochemical regeneration of CO 2 from bicarbonate-based carbon capture solutions and seawater using BPM-ED. For DAC, our experimental and computational results demonstrate that pH swings induced by BPM water dissociation drive the formation of CO 2 at the cation-exchange layer|catholyte interface with energy-intensities of less than 150 kJ mol -1 . However, high rates of bubble formation increase energy intensity at current densities >100 mA cm -2 . Correspondingly, accelerating water dissociation catalysis and enacting bubble removal could enable CO 2 recovery at energy intensities <100 kJ mol -1 and current densities >100 mA cm -2 . For DOC, mass transport limitations associated with low carbon concentrations in oceanwater suggest that DOC is best suited for clean production of acid and base usable in downstream processes. Further, these results provide design principles for industrial-scale CO 2 recovery using BPM-ED.

54 ENVIRONMENTAL SCIENCES↗

Study of 149 Sm Capture and Total Cross Sections for Burnup Credit Applications [Slides]

This presentation highlights how capture and transmission measurements were performed with the DANCE (Detector for Advanced Neutron Capture Experiments) instrument with capture data from 8 eV – 1 keV, and DICER (Device for Indirect Capture Experiments on Radionuclides) instruments with transmission data from 1meV – 1 keV. There were additional measurements of 147 Sm which had contaminant in the samples, 3.4 eV strong resonance, interesting abnormalities. The data analysis is complete and the R-Matrix analysis almost (90%) complete.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Strategic Siting of Direct Air Capture Facilities in the United States

Direct air capture (DAC) systems that capture carbon dioxide (CO 2 ) directly from the atmosphere are garnering considerable attention for their potential role as negative emission technologies in achieving net-zero CO 2 emission goals. Common DAC technologies are based either on liquid–solvent (L-DAC) or solid–sorbent (S-DAC) to capture CO 2 . A comprehensive multi-factor comparative economic analysis of the deployment of L-DAC and S-DAC facilities across various United States (U.S.) cities is presented in this paper. The analysis considers the influence of various factors on the favorability of DAC deployment, including local climatic conditions such as temperature, humidity, and CO 2 concentrations; the availability of energy sources to power the DAC system; and costs for the transport and storage of the captured CO 2 along with the consideration of the regional market and policy drivers. The deployment analysis in over 70 continental U.S. cities shows that L-DAC and S-DAC complement each other spatially, as their performance and operational costs vary in different climates. L-DAC is more suited to the hot, humid Southeast, while S-DAC is preferrable in the colder, drier Rocky Mountain region. Strategic deployment based on regional conditions and economics is essential for promoting the commercial adoptability of DAC, which is a critical technology to meet the CO 2 reduction targets.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Direct Air Capture and Utilization System (DACUS): FEED Study of CarbonCapture Inc. DAC and CarbonCure Utilization Technologies Using United States Steel’s Gary Works Plant Waste Heat

The effects of climate change are drastically perceived through the alarming rates of severe events such as flooding, hurricanes, wildfires, global temperature rise, sea-level rise, and ocean acidification etc., which has prompted the nations across the globe to control & reduce greenhouse gas (GHG) emissions, by massive adoption of electric vehicles, switching to renewal energy sources and promoting sustainable green products. However, recent climate studies have shown that such efforts will not be enough to keep the global temperature rising under 1.5° Celsius by the year 2050, which lead to the development of multiple Direct Air Capture (DAC) technologies. A DAC system extracts CO2 directly from the atmosphere, which is either stored underground for long term or utilized in other processes. The DACUS proposed at U.S. Steel Corporation’s Gary Works Plant in Gary, Indiana, will include an innovative DAC technology from CarbonCapture Inc. (CCI), which will be collocated and powered by waste heat from the steel plant to capture CO2 from ambient air, and CarbonCure CO2 utilization technology- which is a commercial technology that is already installed and in use by early adopters in more than 150 concrete mixing plants across North America and Asia. The University of Illinois at Urbana Champaign spearheaded this Front-End Engineering Design (FEED) study project, which was funded by US Department of Energy (DOE), aimed at designing a state-of-the art DACU system that can remove minimum of 5,000 tonne/year net CO2 from air (based on cradle-to-gate LCA) and converting the captured CO2 into low carbon intensity products. The off takers of the low Carbon product produced by the DACUS have also been identified near the steel plant in the Indiana, Illinois & Wisconsin Region. This creates a full CO2 value chain and provides a means to assess the impact of this holistic approach on job creation, regional economic impact, and environmental justice. DACUS is a promising new technology for reducing greenhouse gas in the atmosphere. Operation costs are minimized by locating CCI’s innovative DAC collector at United States Steel's Gary Works site where waste heat is utilized. Carbon emissions are minimized in CO2 transportation. The captured CO2 will be permanently sequestered in concrete used as construction material. This DOE funded FEED study demonstrates a full CO2 value chain for a DACU system, supported by an industrial facility. If this project were constructed, it would have a very positive and lasting impact on both the environment and the community.

42 ENGINEERING↗

Developing a roadmap for carbon capture, and storage in Oklahoma by assessing the viability of stacked storage

Abstract The Intergovernmental Panel on Climate Change concludes that CO 2 capture and storage (CCS) is critical for climate‐stabilizing energy transitions. In CCS, captured CO 2 is sequestered in saline aquifers within sedimentary basins. The CO 2 storage capacity and the rate of injection are functions of the geology of the saline aquifer, which is uncertain. To minimize impacts of this uncertainty, CCS projects could include backup plans, such as co‐locating geologic CO 2 storage (GCS) sites with or near existing CO 2 ‐enhanced oil recovery (CO 2 ‐EOR) operations. These “stacked storage” projects could hedge against uncertainty in the saline formation performance because captured CO 2 could be injected into either location in the event of unexpected events (e.g., the injectivity decreases). Here, we investigate the possibility and ramifications of developing CCS networks in Oklahoma that are amendable to stacked storage. We find that stacked storage is possible in Oklahoma but the counties with the lowest‐cost saline storage resources do not have existing CO 2 ‐EOR operations. At the systems level, we find it is slightly more expensive (e.g., $1/tCO 2 to $5/tCO 2 ) to site GCS in counties with CO 2 ‐EOR projects. This increased expense is largely due to increased CO 2 transportation costs because hundreds of km of additional pipeline is required to capture CO 2 from the lowest‐cost sources. Overall, our results suggest that it is optimal to build more pipelines and avoid injecting CO 2 in some of the lowest‐cost saline storage resources, to enable capturing CO 2 from the least‐cost sources. © 2023 Society of Chemical Industry and John Wiley & Sons, Ltd.

42 ENGINEERING↗

Fully Automated Laser Ablation Liquid Capture Sample Analysis using NanoElectrospray Ionization Mass Spectrometry

RATIONALE: Laser ablation provides for the possibility of sampling a large variety of surfaces with high spatial resolution. This type of sampling when employed in conjunction with liquid capture followed by nanoelectrospray ionization provides the opportunity for sensitive and prolonged interrogation of samples by mass spectrometry as well as the ability to analyze surfaces not amenable to direct liquid extraction. METHODS: A fully automated, reflection geometry, laser ablation liquid capture spot sampling system was achieved by incorporating appropriate laser fiber optics and a focusing lens into a commercially available, liquid extraction surface analysis (LESA ) ready Advion TriVersa NanoMate system. RESULTS: Under optimized conditions about 10% of laser ablated material could be captured in a droplet positioned vertically over the ablation region using the NanoMate robot controlled pipette. The sampling spot size area with this laser ablation liquid capture surface analysis (LA/LCSA) mode of operation (typically about 120 m x 160 m) was approximately 50 times smaller than that achievable by direct liquid extraction using LESA (ca. 1 mm diameter liquid extraction spot). The set-up was successfully applied for the analysis of ink on glass and paper as well as the endogenous components in Alstroemeria Yellow King flower petals. In a second mode of operation with a comparable sampling spot size, termed laser ablation/LESA , the laser system was used to drill through, penetrate, or otherwise expose material beneath a solvent resistant surface. Once drilled, LESA was effective in sampling soluble material exposed at that location on the surface. CONCLUSIONS: Incorporating the capability for different laser ablation liquid capture spot sampling modes of operation into a LESA ready Advion TriVersa NanoMate enhanced the spot sampling spatial resolution of this device and broadened the surface types amenable to analysis to include absorbent and solvent resistant materials.

alstroemeria↗

Development of Holmium-163 electron-capture spectroscopy with transition-edge sensors

Calorimetric decay energy spectroscopy of electron-capture-decaying isotopes is a promising method to achieve the sensitivity required for electron neutrino mass measurement. The very low total nuclear decay energy (Q EC < 3 keV) and short half-life (4570 years) of 163 Ho make it attractive for high-precision electron-capture spectroscopy (ECS) near the kinematic endpoint, where the neutrino momentum goes to zero. In the ECS approach, an electron-capture-decaying isotope is embedded inside a microcalorimeter designed to capture and measure the energy of all the decay radiation except that of the escaping neutrino. We have developed a complete process for proton irradiation-based isotope production, isolation, and purification of 163 Ho. We have developed transition-edge sensors for this measurement and methods for incorporating 163 Ho into high-resolution microcalorimeters, and have measured the electron-capture spectrum of 163 Ho. Finally, we present our work in these areas and discuss the measured spectrum and its comparison to current theory.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Experimental investigation of the effect of pore size distribution on nano-particle capture efficiency within ceramic particulate filters

The effect of the pore size distribution on size-resolved filtration efficiency was investigated for two ceramic particulate filters using particulate matter (PM) generated by a spark-ignition direct-injection engine fueled with gasoline. The cordierite filter tested had a porosity of 43%, a median pore diameter (d_50) of 12 µm, and a wide pore size distribution with a lognormal standard deviation (s’) of 0.3. The aluminum titanate filter had very similar porosity, d_50, and thickness, but significantly narrower pore size distribution (s’ = 0.1). The testing of two filters under identical experimental conditions enabled the impact of the pore size distribution on filtration performance to be evaluated. Filtration experiments were performed focusing on just the filter wall, starting from a clean filter until the transition to cake filtration (filtration efficiency > 99%). Time-resolved particle size distribution measurements were used to evaluate the progression of filtration performance and estimate trapped mass within the filter. The aluminum titanate filter, with a narrow pore size distribution, exhibited significantly better diffusion capture efficiency. The negative impact of higher flow velocity on diffusion capture efficiency was more pronounced for a narrower pore size distribution. Flow distributions measured using capillary-flow porometry were used to develop a cylindrical pore flow model to understand the impact of the differences in pore size distribution on observed trends in diffusion capture efficiency within a clean filter. The model helps demonstrate how large pores on the high end of a wider pore size distribution can carry a large fraction of the flow, with less efficient capture of small particles by diffusion. The experimental results and data demonstrate that the bubble point diameter and width of the pore size distribution significantly influence diffusion capture efficiencies for filters with very similar median pore diameter, porosity, and thickness.

aerosol filtration, Aftertreatment, ceramic exhaus↗

Clustering representative days for power systems generation expansion planning: Capturing the effects of variable renewables and energy storage

Decision makers rely on models to make important regulatory, policy, and investment decisions. For power systems, these models must capture (i) the future challenges introduced by the integration of large quantities of variable renewable energy sources and (ii) the role that energy storage technologies should play. In this paper, we explore several different approaches to selecting representative days for generation expansion planning models, focusing on capturing these dynamics. Further, we propose a new methodology for adjusting the outputs of clustering algorithms that provides three advantages: the targeted level of net demand is captured, the underlying net demand shapes that define ramping challenges are accurately represented, and the relationship between annual energy and peak demand is captured. This weighting methodology reduces the magnitude of the error in the representative day based generation expansion planning models estimation of costs by 61% on average. The results also demonstrate the importance of carefully performing the clustering of representative days for both system costs and technology mix. In most cases improvements to the total cost of different representative day based expansion plans are realised where conventional generation capacity is substituted for energy storage. Based on the energy storage technology selected we conclude this capacity is being used to address ramping challenges as opposed to shifting renewable generation from off to on peak periods, reinforcing the importance of capturing detailed intraday dynamics in the representative day selection process.

Clustering↗

Incorporation of market signals for the optimal design of post combustion carbon capture systems

Recent studies have shown that fossil generators equipped with post-combustion carbon capture (PCC) systems are needed to reduce the cost of deep decarbonization. Such generators need to be flexible and responsive to grid conditions, particularly in a high variable renewable energy (VRE) environment. In this work, we evaluate the net present value (NPV) of retrofitting an existing natural gas combined cycle (NGCC) unit with a flexible PCC system while incorporating market signals from a high VRE grid. We use our industrial partner’s NGCC configuration as representative of existing NGCC units and Svante’s rapid-temperature swing adsorption (TSA) for PCC. Because of its ability to rapidly startup/shutdown and ramp-up/ramp-down, the chosen capture technology is very attractive for load-following operations. For a given set of market signals, we formulate a two-stage stochastic multi-period optimization problem, under the price-taker assumption, to simultaneously optimize the design of the capture system and operation of the entire plant. Rigorous models for the NGCC unit, PCC system, and compression system are developed using commercial process simulators and validated with either plant or vendor data. For computational tractability, we develop surrogate/reduced-order models for use in the optimization problem. The surrogate model for the NGCC plant is constructed by linearizing the rigorous dynamic model at 75% load, while data-driven nonlinear surrogate models for the capture and compression systems are constructed using simulation data from the rigorous models. The optimization problem, formulated as a mixed integer bilinear program, is implemented in the IDAES® integrated platform and solved to global optimality using Gurobi 9.5. Using this formulation, we determine the profitability of retrofitting an existing NGCC unit with the chosen capture system for multiple regions in the U.S. under two scenarios with different carbon prices. Importantly, the results show that the optimal decision strongly depends on the region and on the carbon price, thereby demonstrating the importance of the inclusion of market signals in the design process.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Intensified Co-electrolysis Process for Syngas Production from Captured CO 2

CO 2 reduction to syngas provides a way of ameliorating carbon footprint and storing energy in high-energy-density and versatile feedstock. This current work explores the isothermal integration of CO2 capture with an intensified unit operation for the reduction of CO2 and capture media regeneration. Intensified captured CO2 co-electrolysis (ICC) to syngas (H2:CO ratio of 2) with low CO2 content (<10%) was demonstrated with over 70% CO2 conversion at a current density up to 0.20 A/cm2 for 14 hours of operation. Integration of the co-electrolysis unit with CO2 capture was performed feeding pure and diluted CO2, for which CO2 conversions >65% were observed. Performance of the capture unit becomes critical to maintain syngas ratios (SR). Technology feasibility was assessed through comparative techno-economic and life cycle analysis showing that process intensification enables competitive performance, even at the higher energy consumption featured at the current state of the technology. This because several unit operations can be avoided. LCA also showed that based on the current US electricity mix the reduction of life cycle CO2 emissions is possible at scenarios observed with 0.15 A/cm2 to accomplish a carbon-negative technology.

08 HYDROGEN↗

Novel techniques for constraining neutron-capture rates relevant for r -process heavy-element nucleosynthesis

The rapid-neutron capture process (r process) is identified as the producer of about 50% of elements heavier than iron. This process requires an astrophysical environment with an extremely high neutron flux over a short amount of time ( seconds), creating very neutron-rich nuclei that are subsequently transformed to stable nuclei via beta decay. In 2017, one site for the r process was confiimed: the advanced LIGO and advanced Virgo detectors observed two neutron stars merging, and immediate follow-up measurements of the electromagnetic transients demonstrated an "afterglow" over a broad range of frequencies fully consistent with the expected signal of an r process taking place. Although neutronstar mergers are now known to be r-process element factories, contributions from other sites are still possible, and a comprehensive understanding and description of the r process is still lacking. One key ingredient to large-scale r-process reaction networks is radiative neutron-capture ( n , &#x3B3; ) rates, for which there exist virtually no data for extremely neutron rich nuclei involved in the r process. Due to the current status of nuclear-reaction theory and our poor understanding of basic nuclear properties such as level densities and average g-decay strengths, theoretically estimated ( n , &#x3B3; ) rates may vary by orders of magnitude and represent a major source of uncertainty in any nuclear-reaction network calculation of r-process abundances. Here in this review, we discuss new approaches to provide information on neutron-capture cross sections and reaction rates relevant to the r process. In particular, we focus on indirect, experimental techniques to measure radiative neutron-capture rates. While direct measurements are not available at present, but could possibly be realized in the future, the indirect approaches present a first step towards constraining neutron-capture rates of importance to the r process.

(n, γ,) cross sections↗

Ultra-fast microwave regeneration of CO 2 solid sorbents for energy-efficient direct air capture

Large-scale deployment of direct air capture (DAC) technologies has become critical for mitigating climate change. Towards this end, energy-efficient regeneration of the sorbents used in the process of carbon capture from air is very important to significantly reduce the high operational cost of DAC. Guanidine compounds can be used with environmentally friendly aqueous amino acids (e.g., potassium sarcosinate) for fast and effective CO 2 capture from air, and have a strong potential for low-energy CO 2 release and sorbent regeneration. In this process, the amino acid absorbs the CO 2 from the air, and the guanidine compounds react with the CO 2 -rich amino acid solution and crystallize as an insoluble carbonate salt. Separation and thermal regeneration of the precipitated guanidine carbonate salt leads to an overall low-temperature and low-energy direct air capture process. Effective CO 2 release from the solid guanidine compound can be achieved by mild heating at 120 °C. Here, in this study, to overcome the relatively inefficient traditional conductive heating of the crystalline solid (i.e., Methylglyoxal-bis(iminoguanidine) carbonate, MGBIG carbonate), we evaluated the feasibility of microwave heating of MGBIG carbonate in terms of power requirement, radiation time, and solids mass for efficient CO 2 desorption. The energy consumption needed by a microwave oven and a conventional oven to regenerate the same mass of the sorbent was directly measured to compare the total energy required per unit mass of regenerated sample and provide an understanding of the potential benefits of microwave regeneration. We found that microwave heating effectively regenerates MGBIG carbonate, which may be facilitated by the water molecules that are co-crystallized with carbonate in the guanidine crystals. Microwave heating at 2.54 GHz with 1250 W is up to 17 times faster than conventional conductive heating at 160 °C, resulting in 40 % electrical energy reduction. These results indicate that microwave regeneration may be an energy-efficient method for fast regeneration of solid sorbents used for direct air capture.

42 ENGINEERING↗