Search NASA⌕ Search

SEARCH · Search NASA

Results for “Decarbonization Potential”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

Hydrogen Applications for Energy Transition in Port and Airport Operations at the Port Authority of New York and New Jersey

The Port Authority of New York and New Jersey (PANYNJ) is focused on achieving meaningful reductions in emissions as part of its environmental sustainability efforts. To reach its 2030 target for reducing Scope 1 and Scope 2 carbon dioxide equivalent (CO2e) emissions and its goal of net-zero emissions by 2050, PANYNJ is exploring a range of energy solutions, including hydrogen technologies. This report evaluates the potential role of hydrogen in reducing emissions across key operational areas: vehicles, equipment, stationary power, aviation propulsion, and marine propulsion. It examines hydrogen's technical feasibility, infrastructure needs, and economic implications within PANYNJ's operational context. The findings aim to inform decisions as PANYNJ transitions to cleaner energy sources and reduces environmental impacts. Based on the existing literature and stakeholders' feedback, the report outlines both opportunities and challenges associated with hydrogen integration, providing insights to guide PANYNJ's future sustainability initiatives.

33 ADVANCED PROPULSION SYSTEMS↗

Thermal Storage Integrated into Air-Source Heat Pumps to Leverage Building Electrification: A Systematic Literature Review

Air-source heat pumps (ASHPs) can support a decarbonized economy by replacing combustion appliances in homes and electrifying heating systems in buildings. However, ASHPs have not seen significant adoption primarily due to deteriorated performance under cold conditions - at very low temperatures they require auxiliary resistance heating to meet the heating demand and defrost the evaporator. The additional heat lowers the system efficiency. Thermal energy storage (TES) is a candidate technology to help overcome some of these issues. This paper presents a systematic literature review to map the existing research on the integration of TES into ASHPs. Our review of 59 publications indicates that thermal storage increases the ASHP coefficient of performance by 27% on average, albeit with higher initial cost compared to conventional fossil-fueled heating systems. Phase change materials may be ideal to be integrated with ASHPs due to their high energy density and compact design, but only a few publications address TES sizing and design. First and Second Laws of Thermodynamics are widely used to create metrics to assess ASHP-TES integration, and only recently have cost and environmental impact been explored. This literature review suggests that more comprehensive metrics are needed to evaluate the potential benefits of ASHP-TES systems.

air source heat pump↗

Demonstration of the carbon capture with building make-up air unit

Building-integrated carbon capture technology has the potential to reduce the cost of CO 2 capture while improving indoor air quality (IAQ). To promote the adoption of CO 2 capture in a building environment, this study investigated the possibility of integrating carbon capture technology with an existing rooftop make-up air unit (MAU) system to trap CO 2 . Here, in this study, a modular compact CO 2 capture system containing amine-functionalized polymer fibers was examined. The system, which was installed at the exhaust of the MAU, captures CO 2 before it leaves the building to enter the atmosphere as a greenhouse gas. The demonstrated average amount of CO 2 captured was 1.1–1.4 mmol/g of adsorbent material. Techno-economic analysis (TEA) was further performed on the CO 2 capture system, considering material costs, energy costs, as well as transportation and regeneration costs. These results were then used to estimate the levelized cost per ton CO 2 captured (LCOC). To achieve LCOC below $\$$100/t-CO 2 , adsorbents should have working capacities of 4.9 t and 3 t-CO 2 /year for 5 years and 10 years of operation, respectively. In summary, this study highlights a viable path toward the decarbonization of the commercial buildings sector and provides quantitative performance and economic insight on the suitability of building-integrated carbon capture technology.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Design of Phase-Change Thermal Storage Device in a Heat Pump for Building Electric Peak Load Shaving: Preprint

Replacing carbon-intensive fossil fuel heating systems with electric heat pumps powered by renewables is a promising approach to decarbonize the building sector. However, one of the technical barriers of this approach is the large scale of heat demand, which will put excessive stress on the electricity grid. Integrating thermal energy storage (TES) into the heating systems can help alleviate this problem, by shifting thermal load and thus shaving peaks in the building electric load. Therefore, it is critical to understand how to design a thermal storage device in a heat pump for peak load shaving. In this study, we developed a numerical model for a cascaded vapor compression heat pump system integrating a phase change thermal storage device. This novel system can control the net thermal charging and discharging rate of the TES independently from the building's thermal load, which allows for precise control of electric power use. In the current study, we controlled the system to shave building electric peak load during a cold winter morning, and to charge TES during the relatively warm afternoon while still providing space heating. We used the model to evaluate the system performance with and without peak shaving. We also investigated the effect of PCM transition Tt on the peak reduction and electric energy saving potentials. The results show that peak shaving scheme effectively reduces the peak electric power consumption during a predefined discharge time window. When comparing to the no shaving case, for PCM Tt = 10 degrees C, the peak electric load reduction is 23.5%. When comparing to an air-source heat pump with back up electric heater, as Tt increases from 0 to 20 degrees C, the peak reduction increases from 46.1% to 50.9%. Integrating PCM Tt = 10 degrees C with peak shaving leads to the 45.5% of electric energy saving, which is the highest among the three transition temperatures.

electric energy saving↗

Hydropower representation in water and energy system models: a review of divergences and call for reconciliation

Abstract Reservoir-based hydropower systems represent key interactions between water and energy systems and are being transformed under policy initiatives driven by increasing water and energy demand, the desire to reduce environmental impacts, and interacting effects of climate change. Such policies are often guided by complex system models, whereby divergence in system representations can potentially translate to incompatible planning outcomes, thereby undermining any planning that may rely on them. We review different approaches and assumptions in hydropower representation in water and energy systems. While the models and issues are relevant globally, the review focuses on applications in California given its extensive development of energy and water models for policy planning, but discusses the extent to which these observations apply to other regions. Structurally, both water-driven and energy-driven management models are similar. However, in energy models, hydropower is often represented as a single-priority output. Water management models typically allocate water for competing priorities, which are generally uninformed by dynamic electricity load demand, and often result in a lower priority for hydropower. In water models, constraints are increasingly resolved for non-energy components (e.g. inflow hydrology and non-energy water demand); few analogues exist for energy models. These limitations may result in inadequate representations of each respective sector, and vastly different planning outcomes for the same facilities between the two different sectors. These divergent modeling approaches manifest themselves in California where poorly reconciled outcomes may affect decisions in hydropower licensing, electricity grid flexibility and decarbonization, and planning for environmental water. Fully integrated water-energy models are computationally intensive and specific to certain regions, but better representation of each domain in respective efforts would help reconcile divergences in planning and management efforts related to hydropower across energy and water systems.

Rheinheimer, David E. (ORCID:0000000315259069)↗

Technoeconomic Analysis of Kraft Pulp Mill Integration with an Advanced Nuclear Reactor

This study focuses on post-combustion capture and oxy-fuel combustion for the boilers at the mill, as well as steam integration with the nuclear power plant. The primary goal of the research outlined in this report is to design, analyze, and document the integration of industrial-scale HTGR with a reference Kraft Pulp Mill. The purpose is to deliver reliable, cost-effective, and sustainable clean energy alternatives while reducing CO2 emissions. Specifically, this study focuses on 6 different scenarios that include carbon capture equipment and some of them use nuclear power to meet the heat and electricity needs of the reference plant. Also, 2 of these scenarios are created while also producing clean hydrogen through integrated High-Temperature Steam Electrolysis (HTSE). This report offers a detailed techno-economic assessment of different scenarios for a Kraft Pulp Mill, including an analysis of tax credits (section 45V, 45Q, and 48E) provided by the Inflation Reduction Act (IRA) of 2022. The evaluation explores the potential economic benefits and challenges of incorporating different configurations, including nuclear energy, into Kraft Pulp Mill operations, with particular attention to energy efficiency, economic implications, and environmental impact. By assessing both the technical feasibility and economic viability, this analysis aims to identify existing gaps and propose solutions for the successful implementation of nuclear integration. The findings are intended to provide valuable insights for stakeholders considering the adoption of advanced nuclear reactors in the pulp and paper industries.

08 HYDROGEN↗

The intrinsic value of bioblendstocks: Prenol as a case study

Decarbonizing the transportation sector is likely to require both electrification and increased incorporation of biofuels and/or bioblendstocks. While the social and environmental benefits of bioblendstocks are well understood, their real value for the fuel producers has not been established. As such, this work considers prenol as a bioblendstock case study to identify sources of intrinsic value to fuel blenders by studying the properties of binary mixtures with gasoline components. The considered refinery blendstocks were samples of full range naphthas from the distillation, fluidized catalytic cracking, isomerization, alkylation, and reforming units. Octane numbers, Reid vapor pressure, distillation curves, and sulfur content were evaluated. Our results indicate the need for adjusting the formulation of the base fuel, depending on the interplay among the properties of the bioblendstock and those of the base fuel. Prenol increased research octane number (RON) and octane sensitivity (OS) of the base fuel, by up to 25 and 10 octane numbers, respectively. Additionally, 10 vol% prenol reduced RVP up to 2.2 psi, for the more volatile blendstock. Thus, considering prenol as a low volatility, RON/OS boosting bioblendstock, the composition of the preferred base fuel was proposed as containing reduced olefins and aromatics, and increase light fractions. The potential impact of this new gasoline formulation on refining processes and products gives rise to direct sources of value to the refiners, such as exporting products to the chemicals market, increasing the value of intermediate refinery streams, decreasing operating severity of certain refinery units, and broadening of the product suite.

09 BIOMASS FUELS↗

Storage Futures Study: Key Learnings for the Coming Decades

This report is the final in NREL's Storage Futures Study, a multiyear research project that explored the role and impact of energy storage in the evolution and operation of the U.S. power sector. The SFS examined the potential impact of energy storage technology advancement on the deployment of utility-scale storage and the adoption of distributed storage, and the implications for future power system infrastructure investment and operations. The research findings and supporting data were published across a series of six reports, culminating in this final, seventh publication that draws upon findings from across the study, previous work, and additional analysis to identify eight key learnings about the future of energy storage and its impact on the power system. The key learnings can help policymakers, technology developers, and grid operators prepare for the coming way of energy storage deployment.

25 ENERGY STORAGE↗

Photovoltaic and Behind-the-Meter Battery Storage: Advanced Smart Inverter Controls and Field Demonstration

Electric utilities have little visibility of the electrical distribution system, and consequently, limited diagnostic capabilities. The distribution grid was designed for a unidirectional power flow, where energy is supplied by few large centralized power plants; however, this is set to change to meet California’s aggressive decarbonization goals. The large-scale deployment of distributed renewable generation, such as photovoltaics (PV), can have many negative effects on an unprepared grid. As illustrated in the California “duck curve,” PV generation modifies load profiles during the day, which causes steep ramping in the evening. This effect indicates the need to revise the electrical grid’s design and operation. This project sought to (a) create a centralized resource in California to test and validate distribution technology controls with industry standard PV, storage, and high-fidelity sensors, (b) support strategic and operational decisions for new grid architectures by providing simulation models, (c) promote new ways to control clusters of PV smart inverters, in accordance with California Rule 21, and (d) innovate, develop, and field test a predictive controller to maximize economic profit for the customer while supporting the grid. The controller was built using the state-of-the-art model predictive control methodology to optimally control behind-the-meter PV and battery storage. In consideration of the duck curve, the controller optimally controls the battery dispatch by charging during excess generation periods and discharging during the critical afternoon demand hours. The controller was evaluated in annual simulations and revealed the potential cost-effectiveness of behind-the-meter battery storage. The simulations showed that the annual electricity bill could be reduced by as much as 35 percent, with a payback period of the investment in battery storage in about 6 years – significantly shorter than the manufacturer’s 10-year warranty. All developed simulation models, the grid event library, and the MPC controller are open-source and available online.

Model Predictive control↗

Sustainable aviation fuels from biomass and biowaste via bio- and chemo-catalytic conversion: Catalysis, process challenges, and opportunities

Sustainable aviation fuel (SAF) production from biomass and biowaste streams is an attractive option for decarbonizing the aviation sector, one of the most-difficult-to-electrify transportation sectors. Despite ongoing commercialization efforts using ASTM-certified pathways (e.g., lipid conversion, Fischer-Tropsch synthesis), production capacities are still inadequate due to limited feedstock supply and high production costs. New conversion technologies that utilize lignocellulosic feedstocks are needed to meet these challenges and satisfy the rapidly growing market. Combining bio- and chemo-catalytic approaches can leverage advantages from both methods, i.e., high product selectivity via biological conversion, and the capability to build C-C chains more efficiently via chemical catalysis. Herein, conversion routes, catalysis, and processes for such pathways are discussed, while key challenges and meaningful R&D opportunities are identified to guide future research activities in the space. Bio and chemo-catalytic conversion primarily utilize the carbohydrate fraction of lignocellulose, leaving lignin as a waste product. This makes lignin conversion to SAF critical in order to utilize whole biomass, thereby lowering overall production costs while maximizing carbon efficiencies. Thus, lignin valorization strategies are also reviewed herein with vital research areas identified, such as facile lignin depolymerization approaches, highly integrated conversion systems, novel process configurations, and catalysts for the selective cleavage of aryl C–O bonds. The potential efficiency improvements available via integrated conversion steps, such as combined biological and chemo-catalytic routes, along with the use of different parallel pathways, are identified as key to producing all components of a cost-effective, 100% SAF.

09 BIOMASS FUELS↗

A Review of Coupled Geochemical–Geomechanical Impacts in Subsurface CO 2 , H 2 , and Air Storage Systems

Increased demand for decarbonization and renewable energy has led to increasing interest in engineered subsurface storage systems for large-scale carbon reduction and energy storage. In these applications, a working fluid (CO 2 , H 2 , air, etc.) is injected into a deep formation for permanent sequestration or seasonal energy storage. The heterogeneous nature of the porous formation and the fluid–rock interactions introduce complexity and uncertainty in the fate of the injected component and host formations in these applications. Interactions between the working gas, native brine, and formation mineralogy must be adequately assessed to evaluate the efficiency, risk, and viability of a particular storage site and operational regime. This study reviews the current state of knowledge about coupled geochemical–geomechanical impacts in geologic carbon sequestration (GCS), underground hydrogen storage (UHS), and compressed air energy storage (CAES) systems involving the injection of CO 2 , H 2 , and air. Specific review topics include (1) existing injection induced geochemical reactions in these systems; (2) the impact of these reactions on the porosity and permeability of host formation; (3) the impact of these reactions on the mechanical properties of host formation; and (4) the investigation of geochemical-geomechanical process in pilot scale GCS. This study helps to facilitate an understanding of the potential geochemical–geomechanical risks involved in different subsurface energy storage systems and highlights future research needs.

08 HYDROGEN↗

End-Use Savings Shapes Measure Documentation: Heat Pump Rooftop Units With Exhaust Air Energy Recovery

This technical report documents the Advanced Rooftop Unit Control End Use Savings Shapes (EUSS) measure, including providing a description of the technology, modeling methods, and the energy savings calculated from applying the measure to applicable across the US commercial building stock using ComStock to quantify its potential. This measure replaces gas furnace and electric resistance rooftop units with high-efficiency variable speed heat pump rooftop units (HP-RTU) that include exhaust air heat or energy recovery. The measure uses the same assumptions and technology as the variable speed HP-RTU measure from EUSS 2023 release 1 but adds energy recovery to precondition outdoor ventilation air to reduce HVAC loads. The HP-RTU compressor lockout temperature is modeled as 0 degrees Fahrenheit; below this temperature, the heat pump is set to shut off. The unit is sized based on the design cooling loads, with backup electric resistance heating addressing any remaining loads including heating hours below the compressor lockout temperature when there is no heat pump heating.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Graphene reinforced UHMWPE fibers

Thermoplastic polymers are increasingly used in electric vehicles, hydrogen fuel cell vehicles, and other decarbonization applications due to their lightweight and formability. Higher-strength polymers are needed to supplant metals in the vehicle structure, thereby reducing mass and improving efficiency. Ultra-high molecular weight polyethylene (UHMWPE) fibers possess one of the highest strength-to-weight ratios of technical polymers, and further improvement via reinforcement by nanofillers, such as graphene, will expand their performance envelope. Here, in this work, UHMWPE/graphene nanocomposite fibers were gel spun and characterized for their morphological, microstructural, thermal, and mechanical properties. The addition of a low fraction of graphene improved the tensile strength of the fibers by 25% and tensile modulus by 32%. Differential scanning calorimetry showed an increase in melting temperature and degree of crystallinity, which indicates improved coordination of the molecular chains induced by the addition of graphene. The reinforcement also affected the cross-sectional shape of the fibers; the aspect ratio of the fibers’ elliptical shape declined with increasing graphene content showing the skeletal effect of the graphene nanofillers in the polymer matrix. The reinforcing effect of graphene declined above a threshold concentration, and theoretical modeling was applied to demonstrate that increased agglomerates led to reduced properties. This work demonstrates a simple, effective method to produce graphene-reinforced UHMWPE fibers and lays a foundation for understanding the potential for leveraging graphene to form ultra-high-performance nanocomposite fibers for myriad engineering applications.

36 MATERIALS SCIENCE↗

Informing electrification strategies of residential neighborhoods with urban building energy modeling

Electrifying end uses is a key strategy to reducing GHG emissions in buildings. However, it may increase peak electricity demand that triggers the need to upgrade the existing power distribution system, leading to delays in electrification and needs of significant investment. There is also concern that building electrification may cause an increase of energy costs, leading to further energy burden for low-income communities. This study uses the urban scale building modeling tool CityBES to assess the electrification impacts of more than 43,000 residential buildings in a neighborhood of Portland, Oregon, USA. Energy efficiency upgrades were investigated on their potential to mitigate the increase of peak electricity demand and energy burden. Simulation results from the calibrated EnergyPlus models show that electrification with heat pumps for space heating and cooling as well as for domestic water heating can reduce CO2e emissions by 38%, but increase peak electricity demand by about 9% from the baseline building stock. Combining electrification measures and energy efficiency upgrades can reduce CO2e emissions by 48% while reducing peak electricity demand by 6% and saving the median household energy costs by 28%. City and utility decision makers should consider integrating energy efficiency upgrades with electrification measures as an effective residential building electrification strategy, which significantly reduces carbon emissions, caps or even decreases peak demand while reducing energy burden of residents.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The Essential Role of Integrated Nuclear-Renewable Energy Systems in Achieving Economy-wide Net Zero Solutions

Background/Objectives. The Biden administration has committed to full decarbonization of the U.S. electricity grid by 2035 and economy-wide net zero emissions by 2050. These aggressive goals demand immediate action if we are to be successful, and they require us to think more holistically about our clean energy options. Focused laboratory initiatives, such as the INL Integrated Energy Systems (IES) Initiative, and multiple programs within the Department of Energy are working together to address these holistic solutions. Approach/Activities. Traditionally, electricity generation and management and meeting energy demands for industry and transportation are considered independently. As we seek to achieve net zero, we need to reassess our energy demands. When we consider overall energy use, only one-third is in the form of electricity. Additional energy demands are in the form of heat or steam for industrial processes, as well as transportation. Emissions across these sectors are much harder to abate, and electrification may not be the best option. Reducing environmental emissions at an affordable cost, while maintaining grid reliability and resilience, will require us to use all of the clean energy resources that we have available. That means coordinating the use of nuclear, renewables, and fossil fuels with carbon capture to meet growing demands for electricity, industrial applications, and mobility. The primary focus of IES research is to assess the technical and economic potential of various IES solutions to enhance the flexibility and utilization of nuclear energy generators working alongside renewable generators to meet an array of energy demands—thereby maximizing the utilization of clean energy resources across all energy sectors. Various energy applications and product streams beyond electricity are being evaluated, ranging from generation of potable water to production of hydrogen, fertilizers, synthetic fuels, and various chemicals. Results/Lessons Learned. This presentation will highlight the wide array of RD&D being conducted to develop and deploy nuclear-based IES that will be key to achieving our net zero goals. By working with key collaborators in the nuclear industry, analytical studies are now becoming a reality in multiple demonstration projects.

08 HYDROGEN↗

Renewable Energy and Efficiency Technologies in Scenarios of U.S. Decarbonization in Two Types of Models: Comparison of GCAM Modeling and Sector-Specific Modeling

Energy system projections from quantitative models inform actions ranging from short-term and local decisions, such as those about technology and infrastructure deployment, and global and long-term negotiations and targets. Computational limits require model designers to balance coverage and resolution (i.e., breadth versus depth). Some models, such as the Global Change Analysis Model (GCAM), represent all energy sources and uses with less resolution than models that focus on a single sector's energy use. GCAM balances global supply and demand of all energy carriers projecting prices using internal calculations for energy sources and costs of greenhouse gas mitigation while capturing interlinkages between the energy system, water, agriculture and land use, the economy, and the climate. This globally comprehensive model was used to frame the Long-Term Strategy of the United States: Pathways to Net-Zero Greenhouse Gas Emissions by 2050, which the White House released in 2021 and has been used to inform national and global economy-wide climate change mitigation discussions and strategy development for decades. Unlike GCAM, sectoral models focus on a portion of the energy sector and with greater detail and resolution. The Regional Energy Deployment System (ReEDS) electricity-sector model, for example, projects electricity system capacity expansion and operation with high-fidelity representation of emerging technologies for deep decarbonization, such as variable renewable energy and energy storage, and integration of these technologies into the electric grid. The Transportation Energy and Mobility Pathway Options (TEMPO) transportation-sector model enables analysis of household choices, with a focus on adoption, charging, and use of electric vehicles. The Scout buildings-sector model supports detailed consideration of the policies and markets that can accelerate the adoption of electrification and energy conservation measures in buildings. Such sector-specific models are instrumental in informing technology research, sectoral planning strategies, and sector-specific aspects of greenhouse gas mitigation strategies in the United States. The integrated multisector and sector-specific modeling approaches represented by GCAM and these sectoral models are complementary. The integrated multisector approach calculates energy pricing and resource allocation within the model, which is important for consistency when future conditions substantially diverge from current conditions in transformative scenarios. The sector-specific approach facilitates representation of granular details across spatial, temporal, technological, and market dimensions that enable exploration of particular interactions and trade-offs. This report presents the results of recent work to explore the differences and trade-offs between these approaches by comparing GCAM with the sector-specific ReEDS, TEMPO, and Scout models. The report compares both model structures and results, and it addresses their potential relevance and applications.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Long-Term Photovoltaic System Performance in Cold, Snowy Climates

As countries around the world transition towards renewable energy, there is increasing interest in using photovoltaic (PV) technologies to help decarbonize northern and alpine communities due to their scalability and affordability. However, a barrier to large-scale adoption of PV in cold climates is long-term performance uncertainty under snowfall, freeze-thaw cycles, low temperatures, and high winds. In this work, we provide a comprehensive review of published silicon degradation rates in cold Koppen-Geiger climate classifications of Dfb (humid continental), Dfc (subarctic), and ET (tundra). We first analyze the system degradation rates of three subarctic ground-mounted photovoltaic sites in North America using the RdTools year-on-year method: an Al-BSF double-axis tracking site in Fairbanks, Alaska (65degrees N); a PERC and silicon heterojunction bifacial vertical and south-tilted site in Fairbanks, Alaska; and a PERC south-facing fixed-tilt site in Fort Simpson, Northwest Territories (62degrees N). Degradation rates of these newly analyzed sites vary between -0.4%/year and -1.5%/year. Combining these data with previously reported cold climate degradation rates, we show that the distribution of cold climate degradation peaks at -0.1%/year to -0.2%/year but has a large tail with rates above -0.5%/year. The average reported cold climate degradation rate is -0.45%/year, whereas the median value is -0.33%/year. These results suggest that despite frequent freeze-thaw cycles and potential exposure to high wind and snow loads, PV systems in cold climates tend to degrade slower than PV systems in warmer climates. The limited sample size of reported degradation rates in cold climates (27) motivates the need for further data acquisition and monitoring efforts as new technologies are deployed.

14 SOLAR ENERGY↗

Defining Infrastructure Feasibility for Hub-Scale Offshore Atlantic Carbon Storage in the Northeastern United States

In the Northeast U.S., deep rock formations along the Atlantic outer continental shelf may have the potential to sequester 150–1136 million metric tons of CO2. However, the design and infrastructure necessary to develop offshore carbon storage in this region is not well defined because there has been little oil and gas exploration and no commercial production. Consequently, an infrastructure feasibility design was completed for a hub-scale offshore CO2 storage system along the Northeast U.S. Atlantic. The design included development of a detailed, site-specific geological model for a location near the Great Stone Dome geological structure in the Baltimore Canyon Trough off the coast of Delaware, Maryland, and New Jersey. A field injection system topology design was completed to portray a design with eight wells in two clusters connected by central manifolds. Reservoir simulations were completed for the injection system that showed the hub may be able to inject 17 million metric tons (MMT) of CO2 per year for thirty years, but injection rates varied substantially across the eight wells. A CO2 pipeline design determined feasible routes from the east coast shoreline to the injection field. Finally, the CO2 injection system design included subsea injection trees, manifolds, and power umbilicals. This is the first study to define large-scale carbon storage design and infrastructure options for the offshore Atlantic, which can help to progress this region towards field characterization and early-mover deployment for future decarbonization in the region.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗