Search NASA⌕ Search

SEARCH · Search NASA

Results for “Dilute solution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

LITERATURE REVIEW OF BORIC ACID SOLUBILITY DATA

A new solvent system is being evaluated for use in the Modular Caustic-Side Solvent Extraction Unit (MCU) and in the Salt Waste Processing Facility (SWPF). The new system replaces the current dilute nitric acid strip solution with 0.01 M boric acid. This literature study is performed to determine if there is a potential for boric acid to crystallize in the lines with emphasis on the transfer lines to the Defense Waste Processing Facility. This report focuses on the aqueous phase chemistry of boric acid under conditions relevant to MCU and SWPF. Operating and transfer conditions examined for the purpose of this review include temperatures between 13 C (McLeskey, 2008) and 45 C (Fondeur, 2007) and concentrations from 0 to 3M in nitric acid as well as exposure of small amounts of entrained boric acid in the organic phase to the sodium hydroxide caustic wash stream. Experiments were also conducted to observe any chemical reactions and off-gas generation that could occur when 0.01 M boric acid solution mixes with 3 M nitric acid solution and vice versa. Based on the low concentration (0.01M) of boric acid in the MCU/SWPF strip acid and the moderate operating temperatures (13 C to 45 C), it is unlikely that crystallization of boric acid will occur in the acid strip solution under process or transfer conditions. Mixing experiments of boric and nitric acid show no measurable gas generation (< 1 cc of gas per liter of solution) under similar process conditions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Integrated Coulomb Blockade Thermometry for Quantum Computing

In our work we present on-chip thermometry concept aimed at improving temperature control during quantum measurements. The key issue addressed is lack of precise temperature monitoring, especially considering the unavoidable thermal resistance between the qubits’ chip and mixing plate of dilution refrigerator. The suggested solution includes a Coulomb Blockade Thermometer (CBT) based on an array of intrinsically normal-conducting tunnel junctions, currently developed at Aalto University. This is a practical solution for superconducting qubit systems.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Functional Surface Coating to Enhance the Stability of LiNi 0.6 Mn 0.2 Co 0.2 O 2

Parasitic reactions are responsible for continuous performance loss during the normal operation and storage of lithium-ion batteries, particularly for those using nickel-rich cathode materials. Among many contributors, residual Li 2 CO 3 on the surface of nickel-rich cathodes plays a detrimental role in promoting parasitic reactions, and hence accelerates the performance loss of those cathode materials. In this work, a wet impregnation process was utilized to convert the detrimental Li 2 CO 3 and LiOH impurities into a beneficial functional surface coating comprising phosphates. Specifically, hydro-phosphates were used as the functional surface modification agents to mitigate the detrimental effect of surface residuals. The best electrochemical performance was achieved by modifying LiNi 0.6 Mn 0.2 Co 0.2 O 2 with a diluted dihydro-phosphate solution (pKa = 7.2), while the metal cation had a negligible impact on the electrochemical performance. This work provides a cheap and simple method for enabling the high performance of nickel-rich cathodes.

25 ENERGY STORAGE↗

Anti-reflection coatings on large area glass sheets

Antireflective coatings which may be suitable for use on the covers of photovoltaic solar modules can be easily produced by a dipping process. The coatings are applied to glass by drawing sheets of glass vertically out of dilute aqueous sodium silicate solutions at a constant speed, allowing the adherent liquid film to dry, then exposing the dried film to concentrated sulfuric acid, followed by a water rinse and dry. The process produces coatings of good optical performance (96.7 percent peak transmission at 0.540 mu M wavelength) combined with excellent stain and soil resistance, and good resistance to abrasion. The process is reproduceable and easily controlled.

Pastirik, E.↗

Polyvinyl pyridine microspheres

Microspheres are produced by cobalt gamma radiation initiated polymerization of a dilute aqueous vinyl pyridine solution. Addition of cross-linking agent provides higher surface area beads. Addition of monomers such as hydroxyethylmethacrylate acrylamide or methacrylamide increases hydrophilic properties and surface area of the beads. High surface area catalytic supports are formed in the presence of controlled pore glass substrate.

Rembaum, Alan↗

Cross-linked polyvinyl pyridine coated glass particle catalyst support and aqueous composition or polyvinyl pyridine adducted microspheres

Microspheres are produced by cobalt gamma radiation initiated polymerization of a dilute aqueous vinyl pyridine solution. Addition of cross-linking agent provides higher surface area beads. Addition of monomers such as hydroxyethylmethacrylate acrylamide or methacrylamide increases hydrophilic properties and surface area of the beads. High surface area catalytic supports are formed in the presence of controlled pore glass substrate.

Rembaum, Alan↗

Polyvinyl pyridine microspheres

Microspheres are produced by cobalt gamma radiation initiated polymerization of a dilute aqueous vinyl pyridine solution. Addition of cross-linking agent provides higher surface area beads. Addition of monomers such as hydroxyethylmethacrylate acrylamide or methacrylamide increases hydrophilic properties and surface area of the beads. High surface area catalytic supports are formed in the presence of controlled pore glass substrate.

Rembaum, Alan↗

Formulating Precursors for Coating Metals and Ceramics

A protocol has been devised for formulating low-vapor-pressure precursors for protective and conversion coatings on metallic and ceramic substrates. The ingredients of a precursor to which the protocol applies include additives with phosphate esters, or aryl phosphate esters in solution. Additives can include iron, chromium, and/or other transition metals. Alternative or additional additives can include magnesium compounds to facilitate growth of films on substrates that do not contain magnesium. Formulation of a precursor begins with mixing of the ingredients into a high-vapor-pressure solvent to form a homogeneous solution. Then the solvent is extracted from the solution by evaporation - aided, if necessary, by vacuum and/or slight heating. The solvent is deemed to be completely extracted when the viscosity of the remaining solution closely resembles the viscosity of the phosphate ester or aryl phosphate ester. In addition, satisfactory removal of the solvent can be verified by means of a differential scanning calorimetry essay: the absence of endothermic processes for temperatures below 150 C would indicate that the residual solvent has been eliminated from the solution beyond a detectable dilution level.

Morales, Wilfredo↗

Improvement of Laser Damage Resistance and Diffraction Efficiency of Multilayer Dielectric Diffraction Gratings by HF-Etchback Linewidth Tailoring

Multilayer dielectric (MLD) diffraction gratings for Petawatt-class laser systems possess unique laser damage characteristics. Details of the shape of the grating lines and the concentration of absorbing impurities on the surface of the grating structures both have strong effects on laser damage threshold. It is known that electric field enhancement in the solid material comprising the grating lines varies directly with the linewidth and inversely with the line height for equivalent diffraction efficiency. Here, they present an overview of laser damage characteristics of MLD gratings, and describe a process for post-processing ion-beam etched grating lines using very dilute buffered hydrofluoric acid solutions. This process acts simultaneously to reduce grating linewidth and remove surface contaminants, thereby improving laser damage thresholds through two pathways.

42 ENGINEERING↗

Rapid and continuous analyte processing in droplet microfluidic devices

The compositions and methods described herein are designed to introduce functionalized microparticles into droplets that can be manipulated in microfluidic devices by fields, including electric (dielectrophoretic) or magnetic fields, and extracted by splitting a droplet to separate the portion of the droplet that contains the majority of the microparticles from the part that is largely devoid of the microparticles. Within the device, channels are variously configured at Y- or T junctions that facilitate continuous, serial isolation and dilution of analytes in solution. The devices can be limited in the sense that they can be designed to output purified analytes that are then further analyzed in separate machines or they can include additional channels through which purified analytes can be further processed and analyzed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Rapid and continuous analyte processing in droplet microfluidic devices

The compositions and methods described herein are designed to introduce functionalized microparticles into droplets that can be manipulated in microfluidic devices by fields, including electric (dielectrophoretic) or magnetic fields, and extracted by splitting a droplet to separate the portion of the droplet that contains the majority of the microparticles from the part that is largely devoid of the microparticles. Within the device, channels are variously configured at Y- or T junctions that facilitate continuous, serial isolation and dilution of analytes in solution. The devices can be limited in the sense that they can be designed to output purified analytes that are then further analyzed in separate machines or they can include additional channels through which purified analytes can be further processed and analyzed.

Strey, Helmut↗

Analysis of countercurrent membrane vapor extraction of a dilute aqueous biosolute

Removal of dilute bioproducts from fermenter broths is a major challenge both to avoid microbe inhibition and to recover solutes economically without water loss. We analyze a proposed new process, membrane vapor extraction (MVE), where semi-volatile dilute aqueous solutes vaporize at the upstream side of an omniphobic, microporous membrane and dissolve into a nonpolar solvent highly favorable to the solutes but not to water. A new membrane-process analysis is outlined and applied to the countercurrent recovery of 2 wt % aqueous butanol by a prototype solvent (dodecane) at 40°C. Thermodynamic phase equilibria, pioneered by the Prausnitz school, are crucial to MVE process design. Over 90% of the feed butanol is recovered with essentially no water loss giving a separation factor of over 1000. Energy requirements in MVE are low. In this study, our design calculations demonstrate that MVE is a viable separation process to remove and recover dilute aqueous biosolutes.

mass-transfer resistance↗

Removal of Pertechnetate From Simulated Nuclear Waste Streams Using Supported Zerovalent Iron

The application of nanoparticles of predominantly zerovalent iron (nanoiron), either unsupported or supported, to the separation and reduction of pertechnetate anions (TcO{sub 4{sup -}}) from complex waste mixtures was investigated as an alternative approach to current waste-processing schemes. Although applicable to pertechnetate-containing waste streams in general, the research discussed here was directed at two specific potential applications at the U.S. Department of Energy's Hanford Site: (1) the direct removal of pertechnetate from highly alkaline solutions, typical of those found in Hanford tank waste, and (2) the removal of dilute pertechnetate from near-neutral solutions, typical of the eluate streams from commercial organic ion-exchange resins that may be used to remediate Hanford tank wastes. It was envisioned that both applications would involve the subsequent encapsulation of the loaded sorbent material into a separate waste form. A high surface area (>200 m{sup 2}/g) base-stable, nanocrystalline zirconia was used as a support for nanoiron for tests with highly alkaline solutions, while a silica gel support was used for tests with near-neutral solutions. It was shown that after 24 h of contact time, the high surface area zirconia supported nanoiron sorbent removed about 50% (K{sub d} = 370 L/kg) of the pertechnetate from a pH 14 tank waste simulant containing 0.51 mM TcO{sub 4{sup -}} and large concentrations of Na{sup +}, OH{sup -}, NO{sub 3{sup -}}, and CO{sub 3{sup 2-}} for a phase ratio of 360 L simulant per kg of sorbent. It was also shown that after 18 h of contact time, the silica-supported nanoiron removed >95% pertechnetate from a neutral pH eluate simulant containing 0.076 mM TcO{sub 4{sup -}} for a phase ratio of 290 L/kg. It was determined that in all cases, nanoiron reduced the Tc(VII) to Tc(IV), or possibly to Tc(V), through a redox reaction. Finally, it was demonstrated that a mixture of 20 mass % of the solid reaction products obtained from contacting zirconia-supported nanoiron with an alkaline waste solution containing Re(VII), a surrogate for Tc(VII), with 80 mass % alkali borosilicate based frit heat-treated at 700 {sup o}C for 4 h sintered into an easily handled glass composite waste form.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Aluminum Hydroxide Solubility in Sodium Hydroxide Solutions Containing Nitrite/Nitrate of Relevance to Hanford Tank Waste

The technical basis to support the One System River Protection Project Integrated Flowsheet assumption for diluting staged direct feed low-activity waste (DFLAW) from the Hanford waste tanks with raw river water must be assessed in light of the risk of aluminum hydroxide (gibbsite) precipitation prior to the subsequent transfer of tank contents into the low-activity waste pretreatment system (LAWPS) and/or the Tank Side Cesium Removal (TSCR) system from days to months after dilution. Aluminum solubility must be predicted as a function of the significant variables that influence gibbsite dissolution and precipitation. These variables include (i) other solution components that meaningfully affect the activity coefficient of either hydroxide or the aluminate ion, particularly nitrate and nitrite; and (ii) temperature. Based on a review of waste solubility data and the impact of dilution on solution stabilities with specific focus on aluminum hydroxide, data gaps associated with the impact of these variables on the prediction of gibbsite solubility with temperature were identified. An experimental program to aid in the prediction of gibbsite solubility in NaOH solutions containing a range of sodium nitrate and sodium nitrite concentrations up to the solubility limit at a range of temperatures has been conducted. The results of these investigations are summarized in this report.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Bench Scale Study of Coating Formulations for Abatement of Mercury Vapor and Recovery of Mercury Spills

A sealant formulation has been developed that effectively mitigates human exposure to elemental mercury vapor evolving from spilled mercury. The sealant may be dispensed using a fogging methodology (for industrial settings) or a common spray bottle (for home or school settings). In parallel, the potential for Hg recovery using strippable coatings was evaluated. Four liquid coatings were evaluated: one fogging fixative (FX2) developed at INL for the containment of surface and airborne contamination and three commercially available strippable decontamination gels (Carboset 441, Encor 449, and Stripcoat TLC Free). Bench scale mercury vapor abatement tests were conducted in an enclosure using FX2 with the addition of a mercury absorbent and a mercury reactant. Testing with FX2 showed the reactant contributed significantly to reducing the rate of mercury evaporation. The reactant had a minimal impact on the mercury evaporation rate for the strippable coatings. The potential of strippable coatings to remove/recover mercury was inferred from the adhesive and cohesive performance of sprayable dilutions of the coatings applied to porous and non-porous surfaces. Testing provided the following results: • Mercury vapor concentration was reduced by a factor of 40 using the reactant enhanced FX2 solution, as well as with dilutions of Carboset and Encor. Dilute Stripcoat was less effective at reducing Hg evaporation. • A 100× reduction in Hg evaporation rate was achieved using a coating of FX + the Hg reactant (a.k.a. FX Hg), compared to uncoated Hg. • A 2× reduction in the Hg vapor accumulation rate was achieved using FX Hg, compared to the strippable coatings. • Strippability and adhesion tests show that dilutions of Carboset and Stripcoat can be stripped from a variety of indoor surfaces. Dilute Encor was not strippable. Results suggest FX Hg and dilute Carboset will likely reduce Hg vapor concentrations, in an indoor setting, to a level at or below the Occupational Safety and Health Administration 8-hour human exposure limit (0.1 mg/m3). FX Hg dispensed via fogging would increase worker safety during remediation and demolition of industrial facilities with high levels of elemental mercury contamination. When applied via spray bottle, FX Hg may provide a safe and convenient method for the mitigation of Hg vapor in residential or commercial settings (e.g., offices, homes, schools). This approach would be most beneficial where recovery of the spilled Hg is impractical. A sprayed then stripped application of dilute Carboset may provide a safe and convenient method for recovery of small Hg spills in residential and commercial settings. Further testing is required to determine if liquid Hg sufficiently adheres to the strippable coating to be recovered in this way. If it can be dispensed as a fog, dilute Carboset could be employed to recover Hg contamination in industrial settings. Testing of the foggability of dilute Carboset is required to assess this potential.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Revisiting the formation of cyclic clusters in liquid ethanol

The liquid phase of ethanol in pure and in non-polar solvents was studied at room temperature using Fourier transform infrared (FT-IR) and {sup 1}H nuclear magnetic resonance (NMR) spectroscopies together with theoretical approach. The FT-IR spectra for pure ethanol and solution in cyclohexane at different dilution stages are consistent with {sup 1}H NMR results. The results from both methods were best explained by the results of the density functional theory based on a multimeric model. It is suggested that cyclic trimers and tetramers are dominated in the solution of cyclohexane/hexane with the concentration greater than 0.5M at room temperature. In liquid ethanol, while the primary components at room temperature are cyclic trimers and tetramers, there is a certain amount (∼14%) of open hydroxide group representing the existence of chain like structures in the equilibria. The cyclic cluster model in the liquid and concentrated solution phase (>0.5M) can be used to explain the anomalously lower freezing point of ethanol (159 K) than that of water (273 K) at ambient conditions. In addition, {sup 1}H NMR at various dilution stages reveals the dynamics for the formation of cyclic clusters.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Derivation of Equivalent Continuous Dilution for Cyclic, Unsteady Driving Forces

This article uses an analytical approach to determine the dilution of an unsteadily-generated solute in an unsteady solvent stream, under cyclic temporal boundary conditions. The goal is to find a simplified way of showing equivalence of such a process to a reference case where equivalent dilution is defined as a weighted average concentration. This derivation has direct applications to the ventilation of indoor spaces where indoor air quality and energy consumption cannot in general be simultaneously optimized. By solving the equation we can specify how much air we need to use in one ventilation pattern compared to another to obtain same indoor air quality. Because energy consumption is related to the amount of air exchanged by a ventilation system, the equation can be used as a first step to evaluate different ventilation patterns effect on the energy consumption. The use of the derived equation is demonstrated by representative cases of interest in both residential and non-residential buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗