Search NASA⌕ Search

SEARCH · Search NASA

Results for “Distributed Power Generation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

Network-Cognizant Design of Decentralized Volt/VAR Controllers

This paper considers the problem of designing decentralized Volt/VAR controllers for distributed energy resources (DERs). The voltage-reactive power characteristics of individual DERs are obtained by solving a convex optimization problem, where given performance objectives (e.g., minimization of the voltage deviations from a given profile) are specified and stability constraints are enforced. The resultant Volt/VAR characteristics are network-cognizant, in the sense that they embed information on the location of the DERs and, consequently, on the effect of reactive-power adjustments on the voltages throughout the feeder. Bounds on the maximum voltage deviation incurred by the controllers are analytically established. Numerical results are reported to corroborate the technical findings.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Comparison of High-Frequency Solar Irradiance: Ground Measured vs. Satellite-Derived

High-frequency solar variability is an important to grid integration studies, but ground measurements are scarce. The high resolution irradiance algorithm (HRIA) has the ability to produce 4-sceond resolution global horizontal irradiance (GHI) samples, at locations across North America. However, the HRIA has not been extensively validated. In this work, we evaluate the HRIA against a database of 10 high-frequency ground-based measurements of irradiance. The evaluation focuses on variability-based metrics. This results in a greater understanding of the errors in the HRIA as well as suggestions for improvement to the HRIA.

14 SOLAR ENERGY↗

Developing a Reduced 240-Bus WECC Dynamic Model for Frequency Response Study of High Renewable Integration

The ongoing changes in the generation resource mix, driven by the rapid adoption of inverter-based resources (IBR) as well as the early retirement of synchronous generators, are bringing new challenges to the planning and operation of bulk electric power systems. Consequently, there is an increasing need to understand, design, and quantify the reliability service provision from IBRs by performing integrated scheduling and dynamic simulations. However, test systems that have consistent scheduling and dynamic models rarely exist largely because of the decoupled nature of the two simulations on a synchronous generator-dominated system. This paper develops the dynamic model of a reduced Western Electricity Coordinating Council (WECC) system. In conjunction with the existing scheduling model, it is suitable for integrating scheduling and dynamic simulations. The reduced 240-bus WECC model reflects the generation resource mix of the Western Interconnection as of 2018. Moreover, the developed dynamic model is validated against field frequency events measured by FNET/GridEye and preserves the dominant inter-area oscillation mode in WECC.

dynamic simulation↗

Development of fast-running eighth core nodal solution

A fast-running, eighth-core solution technique has been developed for the quick core calculations in ANC, the Westinghouse core analysis code based on the nodal expansion method, and the BEACON{sup TM} Core Monitoring System (BEACON). This technique, referred to as 'Fast Eighth' (Fast8), enables users to obtain satisfactory macroscopic core calculation results such as reactivity, axial offset and assembly power much more quickly than calculations performed in the standard full-core or quarter-core geometry. Fast8 uses three techniques: folding the radial geometry into eighth-core geometry, reducing the axial geometry into a coarse axial mesh geometry, and smearing the spacer grids into nodes on-the-fly after the first calculation in the standard geometry. These geometry adjustments in Fast8 contribute to the reduction of the number of neutronic and material nodes while maintaining the reaction rates in each node. The axial mesh condition dependency in Fast8 is investigated in a xenon transient calculation in single assembly geometry, and the Fast8 maximum axial mesh size is determined based on these results. Fast8 is then applied to the load swing calculation, and the results are compared with the reference, full-core geometry, solution. The critical boron concentration and axial offset of Fast8 show good agreement with the reference solutions, and that Fast8 is a good technique for obtaining macroscopic core calculation results in significantly shorter time. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Research and Development of Zinc Air Fuel Cell To Achieve Commercialization Final Report CRADA No. TC-1544-98

The specific goal of this project was to advance the development of the zinc air fuel cell (ZAFC) towards commercial readiness in different mobile applications, including motor bikes, passenger cars, vans, buses and off-road vehicles (golf carts, factory equipment), and different stationary applications including generator sets, uninterruptible power systems and electric utility loading leveling and distributive power.

25 ENERGY STORAGE↗

Fast Quasi-Static Time-Series Simulation for Accurate PV Inverter Semiconductor Fatigue Analysis with a Long-Term Solar Profile

Power system simulations with long-term data typically have large time steps varying from one second to a few minutes. However, for PV inverter semiconductors, the minimum thermal stress cycle occurs over the fundamental grid frequency (50 or 60 Hz). This requires the time step of the fatigue simulation to be around 100 µs. This small time step requires long computation times to process yearly power production profiles. This paper proposes a fast fatigue simulation for inverter semiconductors using the quasi-static time series (QSTS) simulation concept. The proposed simulation calculates the steady state of the semiconductor junction temperature by using a Fast Fourier Transform (FFT). The small thermal cycling during a switching period and even over the fundamental waveform is disregarded to further accelerate the simulation speed. The resulting time step of the fatigue simulation is 15 minutes, which is consistent with the solar dataset. The error of the proposed simulation is 0.16% compared to the fatigue simulation results using the complete thermal stress profile. A PV inverter that responds to a Transactive Energy System (TES) is simulated to demonstrate the use of the proposed fatigue simulation. The proposed simulation has the potential to co-simulate with system level simulation tools that also adopt the QSTS concept.

Liu, Yunting↗

Investigating the Role of Accident Tolerant Cladding on Source Term Reduction for High-Burnup PWRs Using MELCOR

The use of accident tolerant fuel (ATF) cladding can increase coping times during and beyond design basis accidents. While such gains may be incremental, they provide a margin that can potentially be recovered to enable high-burnup (HBU) operation. Realizing such a margin requires demonstrating that the combination of HBU and ATF has not led to an overall increase in source term. This study investigates the influence of cladding technology (Zr-based, Cr-coated Zr, and FeCrAl) and fuel cycle length (18 and 24 months) on radiological dose at the boundary of the exclusion zone for a four-loop pressurized water reactor to investigate whether ATF claddings can provide such benefits. We analyze a recovered large break loss-of-coolant accident scenario to investigate the impact of transient timescale on the benefits of such coping time increases. The simulations have been performed using the MELCOR and MELCOR Accident Consequence Code System codes. For the cases analyzed, increased fuel cycle length did not necessarily increase radionuclide release and hydrogen generation, as these were found to be sensitive to the core power distribution. Similarly, off-site dose consequence is dominated by short-lived radionuclides that tend to saturate earlier in the burnup, so higher burnup operation did not necessarily increase the source term for the phenomena and transients analyzed here. Delays in recovery of the lowpressure safety injection system increase hydrogen production and radionuclide release, especially between 780 s and 1620 s, due to the nonlinear oxidation and core degradation behavior. Results show that Cr-coated Zr enhances safety by delaying heatup and gap release. Here, when uncertainty propagation on oxidation properties is considered, FeCrAl exhibits the lowest overall radionuclide release and off-site dose throughout the spectrum. However, while the considered “base model” performance is superior under delayed injection scenarios, upper-bound cases display hydrogen generation risk comparable to the Zr-based cladding.

Accident Tolerant Fuel↗

Primary Frequency Response with Aggregated DERs

Power networks have to withstand a variety of disturbances that affect system frequency, and the problem is compounded with the increasing integration of intermittent renewable generation. Following a large-signal generation or load disturbance, system frequency is arrested leveraging primary frequency control provided by governor action in synchronous generators. In this work, we propose a framework for distributed energy resources (DERs) deployed in distribution networks to provide (supplemental) primary frequency response. Particularly, we demonstrate how power-frequency droop slopes for individual DERs can be designed so that the distribution feeder presents a guaranteed frequency-regulation characteristic at the feeder head. Furthermore, the droop slopes are engineered such that injections of individual DERs conform to a well-defined fairness objective that does not penalize them for their location on the distribution feeder. Time-domain simulations for an illustrative network composed of a combined transmission network and distribution network with frequency-responsive DERs are provided to validate the approach.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Multi-modular power plant with dedicated electrical grid

A multi-modular power plant includes a plurality of on-site nuclear power modules that generate a power plant output, and a number of power plant systems which operate using electricity associated with a house load of the power plant. A switchyard associated with the power plant may electrically connect the power plant to a distributed electrical grid. The distributed electrical grid may be configured to service a plurality of geographically distributed consumers. Additionally, the switchyard may electrically connect the power plant to a dedicated electrical grid. The dedicated electrical grid may provide electricity generated from the power plant output to a dedicated service load, and the power plant output may be equal to or greater than a combined load of the dedicated service load and the house load. At least a portion of the power plant output may be distributed to both the power plant systems and the dedicated electrical grid.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Can developing countries leapfrog the centralized electrification paradigm?

Due to the rapidly decreasing costs of small renewable electricity generation 'systems, centralized power systems are no longer a necessary condition of universal access to modern energy services. Developing countries, where centralized electricity infrastructures are less developed, may be able to adopt these new technologies more quickly. We first review the costs of grid extension and distributed solar home systems (SHSs) as reported by a number of different studies. We then present a general analytic framework for analyzing the choice between extending the grid and implementing distributed solar home systems. Drawing upon reported grid expansion cost data for three specific regions, we demonstrate this framework by determining the electricity consumption levels at which the costs of provision through centralized and decentralized approaches are equivalent in these regions. We then calculate SHS capital costs that are necessary for these technologies provide each of five tiers of energy access, as defined by the United Nations Sustainable Energy for All initiative. Our results suggest that solar home systems can play an important role in achieving universal access to basic energy services. The extent of this role depends on three primary factors: SHS costs, grid expansion costs, and centralized generation costs. Given current technology costs, centralized systems will still be required to enable higher levels of consumption; however, cost reduction trends have the potential to disrupt this paradigm. By looking ahead rather than replicating older infrastructure styles, developing countries can leapfrog to a more distributed electricity service model. (C) 2016 International Energy Initiative. Published by Elsevier Inc. All rights reserved.

distributed electrification↗

Distributed Coordination of Energy Storage with Distributed Generators

With a growing emphasis on energy efficiency and system flexibility, a great effort has been made recently in developing distributed energy resources (DER), including distributed generators and energy storage systems. This paper first formulates an optimal coordination problem considering constraints at both system and device levels, including power balance constraint, generator output limits, storage energy and power capacity and charging/discharging efficiencies. An algorithm is then proposed to dynamically and automatically coordinate DERs in a distributed manner. With the proposed algorithm, the agent at each DER only maintains a local incremental cost and updates it through information exchange with a few neighbors, without relying on any central decision maker. Simulation results are used to illustrate and validate the proposed algorithm.

Distributed control↗

ARPA-E PNDIODES "PN Junctions by Ion Implantation" Project (Final Report)

Electricity accounts for nearly 40% of the energy generated in the United States, of which 65% is lost to electrical system inefficiency before reaching end-use sectors. Power electronics will play a growing role in this distribution and end-use, with up to 80% of electricity estimated to pass through power electronics from generation to consumption by 2030. This gives technical improvements in power electronics enormous potential to drive efficiency gains throughout the U.S. economy. Current Si-based power architectures including MOSFETs and IGBTs are limited by high losses, low switching frequency, and poor high-temperature performance. Given the material properties of GaN, devices can exhibit a given turn-on resistance and breakdown voltage with a minute fraction of the area of a Si device—all with higher switching speeds. While n-type doping of III-nitrides has reached a high level of maturity and integration into commercialized products, p-type doping presents distinct challenges that requires continued research. The success of the next generation of GaN-based power devices depends in large part on the ability to form selective-area p-type regions, which can be accomplished by ion implantation of the prevailing acceptor dopant, Mg. This approach is relatively inexpensive and is a fab-ready processing step for creation of current-generation power electronic devices including BJTs, IGBTs, and diode rectifiers. However, ion implantation induces lattice damage and creates point defects within the material, which negatively impacts dopant activation annealing. These forms of damage may be removed by high-temperature annealing, however short annealing time and higher pressures are required to prevent decomposition of the material. We approach this challenge through an innovative combination of approaches toward obtaining high-conductivity p-type GaN. By the novel employment of a gyrotron, a microwave source that can be shaped into a highly localized beam to dissipate very high power in a semiconductor target, a wafer of GaN can be annealed in short (<2 s) ‘pulses’ at temperatures of 1450 °C (2640 °F) to achieve p-type activation without appreciable surface degradation. The p-type activation of Mg-implanted GaN can be further aided by co-implantation with N, believed to enhance the removal of point defects that compensate the acceptors dopant. Elevation to such high temperatures for even a short time induces degradation of GaN-to overcome, we have implemented additional measures to retain high-quality crystalline GaN while removing implant damage and activating Mg dopant. A bilayer cap of AlN is deposited by a combination of chemical and physical vapor deposition to protect the GaN surface. To prevent decomposition of GaN loss of N during annealing, a custom vessel—to contain pressurized N while allowing injection of microwave energy—is employed. By detailed study of the interaction of various measures that are implemented to protect the sample surface (GaN), activate the implanted dopants, and mitigate damage of the lattice heating damage during annealing, we are able to achieve p-type GaN and observe recovery of the crystal and removal of substantial density of defects created during the implantation process.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Large-scale optimal control of interconnected natural gas and electrical transmission systems

We present a detailed optimal control model that captures spatiotemporal interactions between gas and electric transmission networks. We use the model to study flexibility and economic opportunities provided by coordination. A large-scale case study in the Illinois system reveals that coordination can enable the delivery of significantly larger amounts of natural gas to the power grid. In particular, under a coordinated setting, gas-fired generators act as distributed demand response resources that can be controlled by the gas pipeline operator. This enables more efficient control of pressures and flows in space and time and overcomes delivery bottlenecks. We demonstrate that the additional flexibility not only can benefit the gas operator but can also lead to more efficient power grid operations and results in increased revenue for gas-fired power plants. We also use the optimal control model to analyze computational issues arising in these complex models. We demonstrate that the interconnected Illinois system with full physical resolution gives rise to a highly nonlinear optimal control problem with 4400 differential and algebraic equations and 1040 controls that can be solved with a state-of-the-art sparse optimization solver. (C) 2016 Elsevier Ltd. All rights reserved.

Chiang, Nai-Yuan↗

Risk-Based Distributionally Robust Optimal Power Flow With Dynamic Line Rating

In this paper, we propose a risk-based data-driven distributionally robust approach to investigating the optimal power flow with dynamic line rating. The risk terms, including penalties for load shedding, wind generation curtailment and line overload, are embedded into the objective function. To robustify the solution, we consider a distributional uncertainty set based on the second-order moment, that captures the correlation between wind generation outputs and line ratings, and also the Wasserstein distance, that hedges against data perturbations. We show that the proposed model can be reformulated as a convex conic program. Approximations of the proposed model are suggested, which leads to a significant reduction of the number of the constraints. For practical large-scale test systems, a distributionally robust optimal power flow model with Wasserstein-distance-based distributional uncertainty set and its convex reformulation are also provided. Simulation results on the 5-bus, the IEEE 118-bus and the Polish 2736-bus test systems validate the effectiveness of the proposed models.

distributionally robust optimization↗