Search NASA⌕ Search

SEARCH · Search NASA

Results for “Distributed optimization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

Distributed Automatic Load-Frequency Control with Optimality in Power Systems

With the increasing penetration of renewable energy resources, power systems face new challenges in balancing power supply and demand and maintaining the nominal frequency. This paper studies load control to handle these challenges. In particular, a fully distributed automatic load control algorithm, which only needs local measurement and local communication, is proposed. We prove that the control algorithm globally converges to an optimal operating point which minimizes the total disutility of users, restores the nominal frequency and the scheduled tie-line power flows, and respects the thermal constraints of transmission lines. It is also shown that the convergence still holds even when inaccurate system parameters are used in the control algorithm. Lastly, the effectiveness, optimality, and robustness of the proposed algorithm are demonstrated via numerical simulations.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Post-synthetic modulation of the charge distribution in a metal–organic framework for optimal binding of carbon dioxide and sulfur dioxide

Modulation of pore environment is an effective strategy to optimize guest binding in porous materials. We report the post-synthetic modification of the charge distribution in a charged metal–organic framework, MFM-305-CH3, [Al(OH)(L)]Cl, [(H2L)Cl ¼ 3,5-dicarboxy-1-methylpyridinium chloride] and its effect on guest binding. MFM-305-CH3 shows a distribution of cationic (methylpyridinium) and anionic (chloride) centers and can be modified to release free pyridyl N-centres by thermal demethylation of the 1- methylpyridinium moiety to give the neutral isostructural MFM-305. This leads simultaneously to enhanced adsorption capacities and selectivities (two parameters that often change in opposite directions) for CO2 and SO2 in MFM-305. The host–guest binding has been comprehensively investigated by in situ synchrotron X-ray and neutron powder diffraction, inelastic neutron scattering, synchrotron infrared and 2 H NMR spectroscopy and theoretical modelling to reveal the binding domains of CO2 and SO2 in these materials. CO2 and SO2 binding in MFM-305-CH3 is shown to occur via hydrogen bonding to the methyl and aromatic-CH groups, with a long range interaction to chloride for CO2. In MFM-305 the hydroxyl, pyridyl and aromatic C–H groups bind CO2 and SO2 more effectively via hydrogen bonds and dipole interactions. Post-synthetic modification via dealkylation of the as-synthesised metal–organic framework is a powerful route to the synthesis of materials incorporating active polar groups that cannot be prepared directly.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Performance Evaluation of Distributed Energy Resource Management Algorithm in Large Distribution Networks

This paper presents performance evaluation of hierarchical optimization and control for distributed energy resource management system (DERMS) in large distribution networks via an advanced hardware-in-the-loop (HIL) platform. The HIL platform provides realistic testing in a laboratory envi-ronment, including the accurate modeling of a full-scale dis-tribution system of 11,000 nodes, the DERMS software con-troller, and 90 power hardware photovoltaics (PVs) and bat-tery inverters. The applied DERMS algorithm is designed based on a real-time optimal power flow algorithm and im-plemented with acceleration design that performs fast dis-patch of simulated PVs and real physical hardware DER devices every 4 seconds.

distributed energy management system (DERMS)↗

Estimation of the Maximum Theoretical Productivity of Fed-Batch Bioreactors

A key step towards the development of an integrated biorefinery is the screening of economically viable processes, which depends sharply on the yields and productivities that can be achieved by an engineered microorganism. In this study, we extend an earlier method which used dynamic optimization to find the maximum theoretical productivity of batch cultures to explicitly include fed-batch bioreactors. In addition to optimizing the intracellular distribution of metabolites between cell growth and product formation, we calculate the optimal control trajectory of feed rate versus time. We further analyze how sensitive the productivity is to substrate uptake and growth parameters.

09 BIOMASS FUELS↗

A numerical analysis of a magnetocaloric refrigerator with a 16-layer regenerator

A numerical analysis was conducted to study a room temperature magnetocaloric refrigerator with a 16-layer parallel plates active magnetic regenerator (AMR). Sixteen layers of LaFeMnSiH having different Curie temperatures were employed as magnetocaloric material (MCM) in the regenerator. Measured properties data was used. A transient one dimensional (1D) model was employed, in which a unique numerical method was developed to significantly accelerate the simulation speed of the multi-layer AMR system. As a result, the computation speed of a multi-layer AMR case was very close to the single-layer configuration. The performance of the 16-layer AMR system in different frequencies and utilizations has been investigated using this model. To optimize the layer length distribution of the 16-layer MCMs in the regenerator, a set of 137 simulations with different MCM distributions based on the Design of Experiments (DoE) method was conducted and the results were analyzed. The results show that the 16-layer AMR system can operate up to 84% of Carnot cycle COP at a temperature span of 41 K, which cannot be obtained using an AMR with fewer layers. Here, the DoE results indicate that for a 16-layer AMR system, the uniform distribution is very close to the optimized design.

36 MATERIALS SCIENCE↗

A Machine Learning-Based Method to Estimate Transformer Primary-Side Voltages with Limited Customer-Side AMI Measurements

Distribution control applications such as volt/var optimization, network reconfiguration, and distribution automation require accurate knowledge of the distribution system state. The lack of sufficient sensors on the primary side of distribution networks often limits the accuracy of the control decisions by these applications. The deployment of advanced metering infrastructure (AMI) provides utilities an opportunity to translate the AMI data on the secondary onto the primary so that it can be used as pseudo-measurements to augment the limited existing measurements on the primary. This paper develops a machine learning based approach for estimating service transformer primary-side voltages by using limited secondary-side AMI measurement. The machine learning model is developed by using random forest algorithm. The estimated primary-side voltages can be used by utilities as pseudo-measurements for distribution control applications. The detailed secondary model topology, which is an essential input data for many existing algorithms, is not required for the proposed method. The performance of the proposed method is validated by using AMI measurements from the field and an actual distribution feeder model of San Diego Gas & Electric Company.

advanced metering infrastructure↗

A Machine Learning-Based Method to Estimate Transformer Primary-Side Voltages with Limited Customer-Side AMI Measurements

Distribution control applications such as volt/var optimization, network reconfiguration, and distribution automation require accurate knowledge of the distribution system state. The lack of sufficient sensors on the primary side of distribution networks often limits the accuracy of the control decisions by these applications. The deployment of advanced metering infrastructure (AMI) provides utilities an opportunity to translate the AMI data on the secondary onto the primary so that it can be used as pseudo-measurements to augment the limited existing measurements on the primary. This paper develops an approach for estimating service transformer primary-side voltages by using limited secondary-side AMI measurements. The estimated primary-side voltages can be used by utilities as pseudo-measurements for distribution control applications. The detailed secondary model topology, which is an essential input data for many existing algorithms, is not required for the proposed method. The performance of the proposed method is validated by using AMI measurements from the field and an actual distribution feeder model of San Diego Gas & Electric Company.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A Machine Learning-Based Method to Estimate Transformer Primary-Side Voltages with Limited Customer-Side AMI Measurements: Preprint

Distribution control applications such as volt/var optimization, network reconfiguration, and distribution automation require accurate knowledge of the distribution system state. The lack of sufficient sensors on the primary side of distribution networks often limits the accuracy of the control decisions by these applications. The deployment of advanced metering infrastructure (AMI) provides utilities an opportunity to translate the AMI data on the secondary onto the primary so that it can be used as pseudo-measurements to augment the limited existing measurements on the primary. This paper develops an approach for estimating service transformer primary-side voltages by using limited secondary-side AMI measurements. The estimated primary-side voltages can be used by utilities as pseudo-measurements for distribution control applications. The detailed secondary model topology, which is an essential input data for many existing algorithms, is not required for the proposed method. The performance of the proposed method is validated by using AMI measurements from the field and an actual distribution feeder model of San Diego Gas & Electric Company.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Hierarchical distributed voltage regulation

Embodiments of the disclosure provide for hierarchically distributed voltage regulation and power flow optimization in a power distribution network. According to one embodiment, a regional coordinator system may determine power flow for an autonomous grid (AG) representing a portion of the distribution network based on a set of voltage parameters from nodes in the AG. The set of voltage parameters my include a current voltage magnitude. The regional coordinator system may provide, to a central controller system of the distribution network, one or more power flow parameters based on the determined power flow for the AG.

Zhou, Xinyang↗

Consensus-Based Control and Optimization of Power System Inertia

The integration of distributed energy resources (DERs), such as solar, wind, and energy storage systems, into power grids through inverter-based resources reduces power system inertia, leading to faster frequency dynamics and potential grid instability. To address this challenge, this paper proposes a distributed, consensus-based approach for the real-time control and optimization of inertia sources (synchronous generators and/or DERs) during system disturbances, enhancing both system stability and economic performance. The distributed control and optimization approach assumes each inertia source exchanges information solely with its neighbor ones, making it easily scalable to large power grid networks. The impacts of the communication connectivity among the inertia sources as well as their generation capacity limits on the distributed approach are investigated. We also demonstrate the approach’s robustness in scenarios involving communication time delays and packet losses, validating its effectiveness through numerical simulations on a 4-bus test system and a two-area 8-bus test system.

Power system inertia↗

Voltage positioning using co-optimization of controllable grid assets in radial networks

With increasing penetration of solar PV, some distribution feeders are experiencing highly variable net-load flows and even reverse flows. To optimize distribution systems under such conditions, the scheduling of mechanical devices, such as OLTCs and capacitor banks, needs to take into account forecasted solar PV and actual grid conditions. However, these legacy switching assets are operated on a daily or hourly timescale, due to the wear and tear associated with mechanical switching, which makes them unsuitable for real-time control. Therefore, there is a natural timescale- separation between these slower mechanical assets and the responsive nature of inverter-based resources. In this paper, we present a network admissible convex formulation for holistically scheduling controllable grid assets to position voltage optimally against solar PV. An optimal hourly schedule is presented that utilizes mechanical resources to position the predicted voltages close to nominal values, while minimizing the use of inverter-based resources (i.e., DERs), making them available for control at a faster time-scale (after the uncertainty reveals itself). A convex, inner approximation of the OPF problem is adapted to a mixed-integer linear program that minimizes voltage deviations from nominal (i.e., maximizes voltage margins). Here, the resulting OPF solution respects all the network constraints and is, hence, robust against modeling simplifications. Simulation based analysis on IEEE distribution feeders validates the approach.

24 POWER TRANSMISSION AND DISTRIBUTION↗

SU-E-T-456: Impact of Dose Calculation Algorithms On Biologically Optimized VMAT Plans for Esophageal Cancer

Purpose: To evaluate the impact of dose calculation algorithm on the dose distribution of biologically optimized Volumatric Modulated Arc Therapy (VMAT) plans for Esophgeal cancer. Methods: Eighteen retrospectively treated patients with carcinoma esophagus were studied. VMAT plans were optimized using biological objectives in Monaco (5.0) TPS for 6MV photon beam (Elekta Infinity). These plans were calculated for final dose using Monte Carlo (MC), Collapsed Cone Convolution (CCC) & Pencil Beam Convolution (PBC) algorithms from Monaco and Oncentra Masterplan TPS. A dose grid of 2mm was used for all algorithms and 1% per plan uncertainty maintained for MC calculation. MC based calculations were considered as the reference for CCC & PBC. Dose volume histogram (DVH) indices (D95, D98, D50 etc) of Target (PTV) and critical structures were compared to study the impact of all three algorithms. Results: Beam models were consistent with measured data. The mean difference observed in reference with MC calculation for D98, D95, D50 & D2 of PTV were 0.37%, −0.21%, 1.51% & 1.18% respectively for CCC and 3.28%, 2.75%, 3.61% & 3.08% for PBC. Heart D25 mean difference was 4.94% & 11.21% for CCC and PBC respectively. Lung Dmean mean difference was 1.5% (CCC) and 4.1% (PBC). Spinal cord D2 mean difference was 2.35% (CCC) and 3.98% (PBC). Similar differences were observed for liver and kidneys. The overall mean difference found for target and critical structures was 0.71±1.52%, 2.71±3.10% for CCC and 3.18±1.55%, 6.61±5.1% for PBC respectively. Conclusion: We observed a significant overestimate of dose distribution by CCC and PBC as compared to MC. The dose prediction of CCC is closer (<3%) to MC than that of PBC. This can be attributed to poor performance of CCC and PBC in inhomogeneous regions around esophagus. CCC can be considered as an alternate in the absence of MC algorithm.

60 APPLIED LIFE SCIENCES↗

Allocating Reserves in Active Distribution Systems for Tertiary Frequency Regulation

This paper proposes a cooperative game theory-based approach for reserve optimization to enable distributed energy resources (DERs) participate in tertiary frequency regulation. Tertiary frequency regulation schemes ensure that reserve requirements of primary and secondary frequency regulation are fulfilled with a minimum cost. While the available reserve from a single distribution system may not suffice tertiary frequency regulation, stacked reserve from several distribution systems can enable them participate in tertiary frequency regulation at scale. In this paper, a two-stage strategy is proposed to effectively and precisely allocate spinning reserve requirement from each DER in distribution systems. In the first stage, two types of characteristic functions are computed: worthiness index (WI) and power loss reduction (PLR). In the second stage, the equivalent Shapley values are computed based on the characteristic functions, which are used to determine distribution factors for reserve allocation among DERs. The effectiveness of the proposed method for allocating reserves among DERs is demonstrated through several case studies on modified versions of the IEEE 13-node and 33-node distribution systems.

Gautam, Mukesh↗