Modeled Results of Four Residential Energy Efficiency Measure Packages for Deriving Advanced Building Construction Research Targets

The Advanced Building Construction (ABC) Initiative from the U.S. Department of Energy Building Technologies Office is working to accelerate industrialized construction innovations for decarbonizing buildings. To inform performance and cost targets for research under the ABC Initiative, this analysis used the ResStock™ tool to evaluate the energy savings, utility bill impacts, and carbon emissions impacts of four simulated upgrade packages with specific target performance levels on a large sample of residential dwelling units (approximately 550,000) representative of the U.S. housing stock.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Building America Case Study: Initial and Long-Term Movement of Cladding Installed Over Exterior Rigid Insulation (Fact Sheet)

Changes in the International Energy Conservation Code (IECC) from 2009 to 2012 have resulted in the use of exterior rigid insulation becoming part of the prescriptive code requirements. With more jurisdictions adopting the 2012 IECC builders are going to finding themselves required to incorporate exterior insulation in the construction of their exterior wall assemblies. For thick layers of exterior insulation (levels greater than 1.5 inches), the use wood furring strips attached through the insulation back to the structure has been used by many contractors and designers as a means to provide a convenient cladding attachment location. However, there has been a significant resistance to its widespread implementation due to a lack of research and understanding of the mechanisms involved and potential creep effects of the assembly under the sustained dead load of a cladding. This research was an extension on previous research conducted by BSC in 2011, and 2012. Each year the understanding of the system discrete load component interactions, as well as impacts of environmental loading has increased. The focus of the research was to examine more closely the impacts of screw fastener bending on the total system capacity, effects of thermal expansion and contraction of materials on the compressive forces in the assembly, as well as to analyze a full years worth of cladding movement data from assemblies constructed in an exposed outdoor environment.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Initial and Long-Term Movement of Cladding Installed Over Exterior Rigid Insulation

Changes in the International Energy Conservation Code (IECC) from 2009 to 2012 have resulted in the use of exterior rigid insulation becoming part of the prescriptive code requirements. With more jurisdictions adopting the 2012 IECC builders are going to finding themselves required to incorporate exterior insulation in the construction of their exterior wall assemblies. For thick layers of exterior insulation (levels greater than 1.5 inches), the use wood furring strips attached through the insulation back to the structure has been used by many contractors and designers as a means to provide a convenient cladding attachment location. However, there has been a significant resistance to its widespread implementation due to a lack of research and understanding of the mechanisms involved and potential creep effects of the assembly under the sustained dead load of a cladding. This research was an extension on previous research conducted by BSC in 2011, and 2012. Each year the understanding of the system discrete load component interactions, as well as impacts of environmental loading has increased. The focus of the research was to examine more closely the impacts of screw fastener bending on the total system capacity, effects of thermal expansion and contraction of materials on the compressive forces in the assembly, as well as to analyze a full years worth of cladding movement data from assemblies constructed in an exposed outdoor environment.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy-Efficient and Comfortable Buildings through Multivariate Integrated Control (ECoMIC)

This project aims to develop an integrated control solution for enhanced energy efficiency and user comfort in commercial buildings. The developed technology is a zone-based control framework that minimizes energy usage while maintaining occupants’ visual and thermal comfort through control of electric lights, motorized venetian blinds and thermostats. The control framework is designed following a modular, scalable and flexible architecture to facilitate easy integration with exiting building management systems. The control framework contains two key algorithms: 1) the lighting load balancing algorithm and 2) the thermostat control algorithm. The lighting load balancing algorithm adopts a model-based closed-loop control approach to determine the optimal electric light and venetian blind settings. It is formulated into an optimization problem with minimizing lighting-related energy consumptions as the objective and delivering adequate task light and preventing daylight glare as the constraints. The thermostat control algorithm is based on a well-established thermal comfort model and formulated as a root-finding problem to dynamically determine the optimal thermostat setpoint for both energy savings and improved thermal comfort. To address building-wide scalability, a system architecture was developed for the zone-based control technology. Three levels of services are defined in the architecture: external services, facility level services and zone level services. The zone-level service includes the control algorithms described above as well as the corresponding interfaces, profiles, sensors and actuators to realize the zone controller. The facility level services connect to the zones through a backbone network, handle supervisory level information and controls, and thus facilitate building-wide scalability. The external services provide communication capability to entities outside of the building for grid interaction and remote access. Various aspects of the developed control technology were evaluated and verified through both simulations and testbed implementations. Simulations coupling a DOE medium office reference building in EnergyPlus building simulation software and a prototype controller in Matlab were performed. During summer time in a mixed-humid climate zone, the simulations revealed reductions of 27% and 42% in electric lighting load and cooling load, respectively, when compared to an advanced base case with daylight dimming and blinds automatically tilted to block direct sun. Two single-room testbeds were established. The testbed at Philips Lighting business building (Rosemont, IL) was designed for quantifying energy performance of integrated controls. This particular implementation achieved 40% and 79% savings on lighting and HVAC energy, respectively, compared to a relatively simple base case operated on predefined schedules. While the resulting energy savings was very encouraging, it should be noted that there may be several caveats associated with it. 1) The test was run during late spring and early summer, and the savings numbers might not be directly used to extrapolate the annual energy savings. 2) Due to the needs for separate control and metering of the small-scale demonstrator within a large building, the HVAC system, hence the corresponding savings, did not represent a typical energy code-compliant design. 3) The light level in the control case was regulated at a particular setpoint, which was lower than then the full-on light level in the base case, and the savings resulted from tuning down the light level to the setpoint was not attributable to the contribution of the developed technology. The testbed at the Lawrence Berkeley National Laboratory (Berkeley, CA) specifically focused on glare control integration, and has demonstrated the feasibility and capability of the glare detection and prevention technique. While the short one-month test in this testbed provided a functional indication of the developed technology, and it would require at least a full solstice-to-solstice cycle to ruinously quantify the performance, which was not possible within the project timeframe. There are certain limitations inherited from the operational assumptions, which could potentially affect the effectiveness and applicability of the developed control technologies. The system takes a typical ceiling-mounting approach for the photosensor locations, and therefore, the control performance relies on proper commissioning or the built-in intelligence of the photosensor for pertinent task light level estimations. For spaces where daylight penetration diminishes significantly deeper into the zone, certain modification to the control algorithms is required to accommodate multiple lighting control subzones and the corresponding sensors for providing a more uniform light level across the entire zone. Integrated control of visual and thermal comfort requires the lighting control zone and thermal control zone to coincide with each other. In other words, the area illuminated by a lighting circuit needs to be the same area served by the thermostat. Thus, the original zoning will potentially constrain the applicability of this technology in retrofitting projects. This project demonstrated the technical feasibility of a zone-based integrated control technology. From the simulation results and testbed implementations, up to 60% lighting energy savings in daylit areas relative to a “no-controls” case can easily be achieved. A 20% reduction of whole building energy consumption is also attainable. In the aspect of occupant comfort, the testbed demonstrated the ability to maintain specified light level on the workplane while promptly mitigate daylight glare 90% of the time. The control system also managed to maintain the thermal environment at a comfortable level 90% of the time. The aspect of system scalability was guaranteed by the system architecture design, based on which the testbeds were instantiated. Analysis on the aspect of economic benefit has yielded an about 6-year payback time for a medium-sized building, including the installation of all hardware and software, such as motorized blinds and LED luminaires. The payback time can be significantly reduced if part of the hardware is already in place for retrofitting projects. It needs to be noted that since the payback analysis was partly based on the testbed performance results, it is constrained by the caveats associated with the testbed implementations. The main uncertainty lies in the contribution from the space conditioning energy savings as it was non-trivial to realistically configure a room-size HVAC system for directly extrapolating whole-building HVAC energy savings. It is recommended to further evaluate the developed technology at a larger scale, where the lighting and HVAC energy consumption can be realistically measured at the building level, to more rigorously quantify the performance potentials.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

TEAMER: Biofouling Analysis for Wave Energy Piston Design - Load Cell Data

Biofouling and corrosion are a major concern for all ocean-deployed components, especially when mechanical motion is involved. Triton has developed the concept of a biofouling mitigation seal as part of the piston sealing assembly for the Triton Wave Energy Converter (TSI-WEC). This mitigation seal has the purpose of preventing the formation of a biofilm on the inside of the piston cylinder. It is hypothesized that the prevention of a biofilm will reduce the amount of macro-biofouling that can occur in the piston assembly. The mitigation seal can also reduce the wear on the main dynamic seal, helping to maintain smooth operation and water-tightness. The cylinder is made from a thermoset composite epoxy, which is resistant to corrosion. However, no studies have researched the material's performance with biofouling. Triton placed two prototype Power Take-Off (PTO) assemblies in a PNNL biofouling tank, one with a biofouling mitigation seal and one without, allowing for an evaluation of seal effectiveness at the prevention of biofouling. In actual WEC operation, wave action would react against the piston, which would drive the linear actuator and electric generator, providing electrical power. In the test setup, this was reversed; a linear actuator was powered to drive the piston in a consistent motion within the cylinder. There are two assemblies: one has a biofouling mitigation seal, the other (control) does not. The following data encompasses a 4 month test period, with load cells being used to monitor piston friction force. Results from this testing will be used to improve seal design and material selection, mitigating risk of premature failure during open water testing and evaluation. This project is part of the TEAMER RFTS 3 (request for technical support) program.

16 TIDAL AND WAVE POWER↗

An Analysis of Representative Heating Load Lines for Residential HSPF Ratings

This report describes an analysis to investigate representative heating loads for single-family detached homes using current EnergyPlus simulations (DOE 2014a). Hourly delivered load results are used to determine binned load lines using US Department of Energy (DOE) residential prototype building models (DOE 2014b) developed by Pacific Northwest National Laboratory (PNNL). The selected residential single-family prototype buildings are based on the 2006 International Energy Conservation Code (IECC 2006) in the DOE climate regions. The resulting load lines are compared with the American National Standards Institute (ANSI)/Air-Conditioning, Heating, and Refrigeration Institute (AHRI) Standard 210/240 (AHRI 2008) minimum and maximum design heating requirement (DHR) load lines of the heating seasonal performance factor (HSPF) ratings procedure for each region. The results indicate that a heating load line closer to the maximum DHR load line, and with a lower zero load ambient temperature, is more representative of heating loads predicted for EnergyPlus prototype residential buildings than the minimum DHR load line presently used to determine HSPF ratings. An alternative heating load line equation was developed and compared to binned load lines obtained from the EnergyPlus simulation results. The effect on HSPF of the alternative heating load line was evaluated for single-speed and two-capacity heat pumps, and an average HSPF reduction of 16% was found. The alternative heating load line relationship is tied to the rated cooling capacity of the heat pump based on EnergyPlus autosizing, which is more representative of the house load characteristics than the rated heating capacity. The alternative heating load line equation was found to be independent of climate for the six DOE climate regions investigated, provided an adjustable zero load ambient temperature is used. For Region IV, the default DOE climate region used for HSPF ratings, the higher load line results in an ~28% increase in delivered heating load and an ~52% increase in the estimated heating operating cost over that given in the AHRI directory (AHRI 2014).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Data for Post-Access Report: Tidal Energy Resource Characterization and Model Validation via the Assessment of Cost-effective Spatially Distributed Current Measurements from microFloat Swarms

This project evaluated how high-resolution, spatially distributed field data can be used to refine and validate site-scale hydrodynamic simulations of tidal channels. Use of such spatially-distributed field observations or site-scale hydrodynamic simulations will be needed for producing accurate predictions of tidal energy production over larger arrays of tidal turbines. The data contained in this archive includes field observations of water velocity from a series of short surveys in Agate Pass taken on August 20th, 2020 using station-keeping ADCP (acoustic doppler current profiler) measurements, drifting downward-looking ADCPs, and microFloats, gathered by researchers at APL-UW under a previous project. It also includes high-resolution hydrodynamic model runs for the site during that time generated under TEAMER support. An explanatory file (.pdf format) describes the survey and field data structure. Processed data is stored in .mat format. Survey summary: start time, number of floats, water level. microFloat data: - Cleaned data for each float in survey, - Time series of position (lat., lon.), depth (relative to surface), and horizontal velocity (u, v) Drifting ADCP data: - Cleaned data for each drifting ADCP in survey - Time series of position (lat., lon.), sample depth (relative to surface), and observed water velocity (u,v,w) Stationary ADCP data: - Cleaned data for each station-keeping data set in survey - Time series of position (lat., lon.), sample depth (relative to surface), and observed water velocity (u,v,w) FVCOM (Finite Volume Coastal Ocean Model) model outputs: Water level and velocity, as well as derived variables (e.g., power density) from the final refined model simulations for the Agate Pass subdomain. Contained in NetCDF and ASCII files for the duration of August 18th and 20th 2020 field surveys. Additional scripts for processing the data and generating the figures in the report are included.

16 TIDAL AND WAVE POWER↗

Initial validation of ALFRED: A Monte Carlo code built on Geant4 for TREAT energy deposition

Predicting the energy deposited in the specimen during an experiment in the Transient Reactor Test (TREAT) Facility is a complex problem due to the nature of the transients occurring in the reactor. In addition, the many particles contributing to energy deposition have different behavior in time and space. ALFRED, a new Geant4 based code, is developed to transport and simulate each particle generated in the core. This code is verified against OpenMC (Open Monte Carlo) on the Godiva benchmark and a simple TREAT model. Next, the energy deposition in TREAT is calculated: 181.05 ± 0.01 MeV for the “instantaneous” energy deposition (which accounts for the energy deposited within 1 s after neutron emission) in fuel and 189.90 ± 0.01 MeV for the total energy deposition in fuel. We discuss these results in this paper with previous calculations and experimental evaluations. This work demonstrates ALFRED’s potential as a high-fidelity tool for computing the spatial and temporal energy deposition in TREAT paving the way for a better understanding of the energy coupling factors in TREAT.

73 - NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Hawaii Wave Surge Energy Converter (HAWSEC) OSU O.H. Hinsdale Basin

The following information and metadata applies to both the Phase I (Hydrodynamics) and Phase II (Full System Power Take-Off) zip folders which contain testing data from the OSU (Oregon State University) O.H. Hinsdale Wave Research Laboratory, from both OSU and the University of Hawaii at Manoa (UH). See zip folders provided further below in the downloads section. For experimental data of the full system, including PTO, see Phase II dataset. There are two main directories in each Phases's zip folder: "OSU_data" and "UH_data". The "OSU_data" directory contains data collected from their DAQ (data acquisition system), which includes all wave gauge observations, as well as body motions derived from their Qualisys motion tracking system. The organization of the directory follows OSU's convention. Detailed information on the instrument setup can be found under "OSU_data/docs/setup/instm_locations". The experiments conducted are documented in the "OSU_data/docs/daq_logs", which provides the trial number to the corresponding data located under "OSU_data/data" in several formats (e.g., ".mat" and ".txt"). Inside the trial directory, data is provided for each of the instruments defined in "OSU_data/docs/setup/instm_locations". The "UH_data" directory contains data collected from their DAQ. The data is stored in a ".tdms" file format. There are free plug-ins for Microsoft Excel and MathWorks MATLAB to read the ".tdms" format. Below are a few links providing methods to read in the data, but a Google search should identify alternatives sources if these no longer exist (valid as of January 2024): Excel: http://www.ni.com/example/27944/en/ MATLAB: https://www.mathworks.com/matlabcentral/fileexchange/30023-tdms-reader The Excel plugin is recommend to get a quick overview of the data. The UH data is organized by directory name, in which the sub-directories for each experiment contains a directory whose name defines the wave height and period for the experimental data within. For example, a directory name "H02_T0275" corresponds to an experiment with wave height 0.1m and a period of 2.75s. For random wave data, the gamma value is also included in the directory name. For example, a directory name "H02_T0225_G18" corresponds to an experiment with a significant wave height of 0.2m, a peak period of 2.25s, and a gamma value of 1.8, with each spectra being a TMA spectrum. For the free decay experiments, the directory name is defined by the initial angular displacement. For example, a directory name "ang05_run01" corresponds to an experiment with an initial angular displacement of 5 degrees. There is a dataset in the UH data for each corresponding experiment defined in the OSU DAQ logs. The ".tdms" data is output from the DAQ at fixed intervals. Therefore, if multiple files are contained within the folder, the data will need to be stitched together. Within the UH dataset, there are two input channels from the OSU DAQ providing a random square wave signal for time synchronization ("ENV-WHT-0010") and a high/low signal ("ENV-WHT-0012") to identify when the wave maker is active (+5V). The UH data is logged as a collection of channel outputs. Channels not in use for the OSU testing (either Phase I or Phase II) are marked "nan" below. If the sensor is disconnected, it will record noise throughout the experiment. Below are the channel definitions in terms of what they measure: GPS Time = time CYL-POS-0001 = position between flap and fixed reference CYL-LCA-0001 = force between flap and hydraulic cylinder REC-LPT-0001 = nan REC-HPT-0001 = nan REC-HPT-0002 = nan REC-HPT-0003 = nan HHT-HPT-0001 = pressure at exhaust ("head" only) REC-FQC-0001 = nan REC-FQC-0002 = nan HHT-FQC-0001 = flow at exhaust ("head" only) ENV-WHT-0001 = nan ENV-WHT-0002 = nan ENV-WHT-0003 = nan ENV-WHT-0010 = random signal from OSU DAQ ENV-WHT-0012 = high/low signal from OSU DAQ Also included is a calibration curve to convert the string pot data to flap pi...

16 TIDAL AND WAVE POWER↗

Fast solvers for tokamak fluid models with PETSc

Multigrid (MG) is widely recognized as a highly effective solver for the model problem, the Laplacian, but textbook MG fails on most problems of interest. MG methods have been applied to complex, real-world applications with careful consideration of the physical model and discretization. In this work we develop the first step in applying MG methods to science and engineering relevant magnetohydrodynamics (MHD) tokamak models in the M3D-C1 (https://m3dc1.pppl.gov) fusion energy science code. The semi-implicit time integrator in M3D-C1 is composed of many linear solves. The implicit advance of the momentum equation is the most challenging and is the focus of this work. The current production solver in M3D-C1 is a block Jacobi (BJ) preconditioner within a Krylov solver, where blocks group degrees of freedom on planes of constant toroidal coordinate. BJ convergence degrades as the number of planes increases due to the spectral properties of the matrix preconditioned with BJ. The partially magnetic field-aligned, regular toroidal grid structure in M3D-C1 is amenable to semi-coarsening geometric MG in the toroidal direction. This paper develops such a solver and demonstrates competitive performance on a runaway electron model of a SPARC (https://cfs.energy/technology/sparc) disruption, and superior robustness on a stellarator model on which the BJ solver fails to converge.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Cosmic ray electrons, positrons and the synchrotron emission of the Galaxy: consistent analysis and implications

A multichannel analysis of cosmic ray electron and positron spectra and of the diffuse synchrotron emission of the Galaxy is performed by using the DRAGON code. This study is aimed at probing the interstellar electron source spectrum down to E ∼< 1GeV and at constraining several propagation parameters. We find that above 4GeV the e{sup −} source spectrum is compatible with a power-law of index ∼ 2.5. Below 4GeV instead it must be significantly suppressed and the total lepton spectrum is dominated by secondary particles. The positron spectrum and fraction measured below a few GeV are consistently reproduced only within low reacceleration models. We also constrain the scale-height z{sub t} of the cosmic-ray distribution using three independent (and, in two cases, original) arguments, showing that values of z{sub t} ∼< 2kpc are excluded. This result may have strong implications for particle dark matter searches.

79 ASTRONOMY AND ASTROPHYSICS↗

Nonlinear structure formation in the cubic Galileon gravity model

We model the linear and nonlinear growth of large scale structure in the Cubic Galileon gravity model, by running a suite of N-body cosmological simulations using the ECOSMOG code. Our simulations include the Vainshtein screening effect, which reconciles the Cubic Galileon model with local tests of gravity. In the linear regime, the amplitude of the matter power spectrum increases by ∼ 20% with respect to the standard ΛCDM model today. The modified expansion rate accounts for ∼ 15% of this enhancement, while the fifth force is responsible for only ∼ 5%. This is because the effective unscreened gravitational strength deviates from standard gravity only at late times, even though it can be twice as large today. In the nonlinear regime (k∼>0.1h Mpc{sup −1}), the fifth force leads to only a modest increase (∼<8%) in the clustering power on all scales due to the very efficient operation of the Vainshtein mechanism. Such a strong effect is typically not seen in other models with the same screening mechanism. The screening also results in the fifth force increasing the number density of halos by less than 10%, on all mass scales. Our results show that the screening does not ruin the validity of linear theory on large scales which anticipates very strong constraints from galaxy clustering data. We also show that, whilst the model gives an excellent match to CMB data on small angular scales (l∼>50), the predicted integrated Sachs-Wolfe effect is in tension with Planck/WMAP results.

79 ASTRONOMY AND ASTROPHYSICS↗

CalWave - TEAMER UMaine 2021 Tank Testing

This is the data submission to the teamer report for RFTS1 during which tank testing at UMaine W2 tank occurred. This submission includes the relevant information and recorded data of CalWave's UMaine wave tank testing conducted under TEAMER Request for Support Round 1. During the testing CalWave assessed an autonomous control approach for changing PTO gain parameters based on "on board" sea state detection. The data submitted includes an overview of normalized PTO gains based on sea state values and for a set of 8 relevant sea states the WEC motion. All data was collected on CalWave's SCADA system and UMaine's motion tracking system. The data submitted suffices the creation of figures as shown in the PDF report submitted alongside the data and the submission includes excel sheets (parameter gains), MATLAB structures (absorber motion), and the mentioned PDF report.

16 TIDAL AND WAVE POWER↗

Identification of RESNET HERS Index Values Corresponding to Minimal Complicance with the IECC Performance Path

This analysis provides a limited evaluation of the relationship between the Residential Energy Services Network (RESNET) Home Energy Rating System (HERS) Index and the simulation-based performance approach used in the 2012 International Energy Conservation Code (IECC). Not all differences between the approaches are analyzed here; only a subset of the distinctions considered likely to result in quantifiable differences in the outcomes of the two approaches or otherwise believed to be of interest to code developers and policy makers are considered. This analysis evaluates, for a single-family residence with various characteristics, the ranges of HERS Index values that would result in compliance with the 2012 IECC.

Taylor, Zachary Todd↗

A Preliminary Feasibility Assessment of the RESNET HERS Index as an Alternative Compliance Path for the IECC

This analysis provides a limited evaluation of the relationship between the Residential Energy Services Network (RESNET) Home Energy Rating System (HERS) Index and the simulation-based performance approach used in the 2012 International Energy Conservation Code (IECC). Not all differences between the approaches are analyzed here; only a few distinctions considered likely to result in quantifiable differences in the outcomes of the two approaches and for which available studies have not quantified those differences. This analysis establishes, for a single-family residence with gas heat and a crawlspace foundation, a set of climate-zone-specific, complying HERS Index values that could be used to inform the development of a HERS-based compliance path in the IECC.

Taylor, Zachary T.↗

Compact Buried Ducts in a Hot-Humid Climate House

A system of compact, buried ducts provides a high-performance and cost-effective solution for delivering conditioned air throughout the building. This report outlines research activities that are expected to facilitate adoption of compact buried duct systems by builders. The results of this research would be scalable to many new house designs in most climates and markets, leading to wider industry acceptance and building code and energy program approval.