Search NASA⌕ Search

SEARCH · Search NASA

Results for “Energy Efficiency Program”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

Driving the Shift to Energy-Efficient and Climate-Responsible Commercial Refrigeration Equipment in Chile

This report provides an overview of global and Chile-specific market trends, technological advancements, and policy developments related to commercial refrigeration equipment, with an emphasis on refrigerated display cabinets. Section 2 examines CRE market trends at the global and Chilean levels. Section 3 presents CRE energy consumption and the latest technological options for improving energy performance. It also discusses low global warming potential (GWP)1 refrigerant options for CRE. Section 4 provides a cost-effectiveness analysis. Section 5 reviews other regional energy efficiency standards and labeling programs and offers potential standard requirements for Chile. Section 6 concludes the report by summarizing key findings and conclusions. Finally, Appendix A provides detailed guidelines intended as a starting point to inform policies and programmes.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The interaction of reactants, intermediates and products with Cu ions in Cu-SSZ-13 NH3 SCR catalysts: An energetic and ab initio X-ray absorption modeling study

Copper-exchanged SSZ-13 (Cu-SSZ-13) provides excellent catalytic activity and hydrothermal stability in the selective catalytic reduction (SCR) of NOx by using NH3 as a reductant. In this contribution, we compare the most likely positions for Cu with a single charge compensating Al atom (ZCu), including the effect of the adsorption of reactants, intermediates and products of a NH3 SCR reaction by using first-principles calculations based on density functional theory. We find that the 6-membered ring (6MR) site is the most energetically favorable while the 8-membered ring (8MR) sites are less favorable with energy differences about 0.5 eV with respect to the 6MR site. Upon molecular adsorption, the energy differences between Cu in the 8MR and 6MR sites decreases and almost disappears, which means that the thermodynamic stability of ZCu with molecularly adsorbed species is nearly identical for Cu in different sites. Considering more complicated scenarios of NO (or CO) adsorption, we find that the co-adsorption of 2 NO (or 2 CO) molecules weakens their interaction with Cu, as well as their co-adsorption with OH and H2O. The X-ray absorption near edge structure (XANES) of Cu in Cu-SSZ-13 under different conditions was also modeled from first principles. We find that the pre-edge feature in the K-edge XANES of Cu in clean Cu-SSZ-13 with Cu in a 8MR site is induced by a 1s to 4s transition while there is no pre-edge peak when Cu is in a 6MR site. Molecular adsorption onto Cu in a 6MR or a 8MR site results in the same K-edge XANES. When NO is adsorbed onto Cu in SSZ-13, we find that the origin of the small pre-edge peak in the K-edge XANES lies in a 1s to 3d electron transition. On the other hand, when CO or N2 is adsorbed onto an isolated Cu atom in SSZ-13, a transition from the 1s state to the hybridized state of 3d and 4p results in a pre-edge peak in the K-edge of the XANES spectrum. It is also found that the edge position and intensity of the maximum peak of Cu K-edge XANES depend on the Cu locations and the adsorbed molecules. By studying the Cu K-edge XANES of ZCu with adsorption of species of different oxidizing power, we conclude that a higher oxidation state of Cu will result in a higher energy edge position in the Cu K-edge XANES. These results are expected to greatly aid our understanding of Cu-SSZ-13 SCR catalysts. This work was supported by institutional funds provided to JSM from the Voiland School of Chemical Engineering and Bioengineering. Financial support was also provided by the National Science Foundation GOALI program under contract Nos. CBET-1258717, CBET-1258715 and CBET-1258690. We thank Prof. Fabio Ribeiro, Mr. Atish Parekh, Prof. W. F. Schneider, Mr. Christopher Paolucci, Mr. Trunjoyo Anggara and Prof. Jeff Miller for stimulating discussions on the modeling of the XANES spectrum and Ms. Alyssa Hensley for her comments on the manuscript. J.Sz. acknowledges the financial support of this work by the U.S. Department of Energy (DOE), Office of Energy Efficiency and Renewable Energy, Vehicle Technologies Program. A portion of the computer time for the computational work was performed using EMSL, a national scientific user facility sponsored by the Department of Energy’s Office of Biological and Environmental Research and located at PNNL. PNNL is a multi-program national laboratory operated for the US DOE by Battelle.

Zhang, Renqin↗

Affordable Cold Climate Infill Housing with Hybrid Insulation Approach, Wyandotte, Michigan (Fact Sheet)

Even builders who are relatively new to energy-efficient construction can consistently reach a target whole house airtightness of 1.5 air changes per hour at 50 Pascals (ACH50) with high R-value enclosures that use a hybrid insulation approach. The City of Wyandotte, Michigan, started a construction program in 2010 to build affordable, energy-efficient homes on lots in existing neighborhoods. A goal of the program was to engage local builders in energy-efficient construction and be able to deliver the new houses for less than $100/ft2. By the end of 2012, approximately 25 new houses were built by five local builders under this program. To help builders consistently achieve the airtightness target, a local architect worked with researchers from Building Science Corporation, a U.S. Department of Energy Building America team, to develop a technology specification with several key pieces. A high R-value wall and roof assembly made use of 2 ?6 advanced framing and a hybrid insulation approach that included insulating sheathing to control thermal bridging and closed cell spray polyurethane foam insulation (ccSPF) for its airtightness and vapor control benefits. This approach allows the air barrier to be completed and tested before any finishing work occurs, ensuring that problems are spotted and corrected early in the construction process.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

2020 Can Do Colorado E-Bike Mini Pilot Program Study

### The Colorado Energy Office conducted a mini pilot program study as part of the Can Do Colorado initiative, providing e-bikes to 13 low-income participants. The program aimed to encourage energy-efficient transportation during the COVID-19 pandemic as transit services were reduced and people were concerned about exposure. The insights garnered from this small-scale pilot study informed the design of a full-scale, 2-year pilot in locations across Colorado. For more information about the mini pilot program, see NLR's [Preliminary Results Report](https://www.nlr.gov/docs/fy21osti/79657.pdf). Micromobility options such as e-bikes offer a solution for improving energy efficiency for short-distance trips, especially in urban areas. Pedal-assist e-bikes use an electric motor and battery to help power the bike. The motor amplifies the power behind each pedal stroke, augmenting the energy you put into the bike. #### Data Collection Agency The Colorado Energy Office conducted the survey. #### Survey Methodology Participants in the program received a Momentum LaFree E+ e-bike (Class 1) and accessories at no cost and manually submitted travel data and feedback for 3 months using the CanBikeCo App. The smartphone app, developed in partnership with NLR, used a customized version of the [NLR OpenPATH platform](https://www.nlr.gov/transportation/openpath.html). #### Survey Records and Data Survey records include a total of 13 participants. This dataset contains 3 months of end-to-end, multimodal travel data manually submitted via smartphone app by 13 low-income essential workers in the greater Denver area. The data includes distance, mode (e.g., e-bike, car, transit), trip purpose, and demographic information.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy Efficiency and Renewable Energy Research, Development, and Deployment in Meeting Greenhouse Gas Mitigation Goals: The Case of the Lieberman-Warner Climate Security Act of 2007 (S. 2191)

The U.S. federal government is considering actions to reduce greenhouse gas emissions. Renewable energy and energy efficiency technologies could help reduce greenhouse gas emissions, so the cost of these technologies could significantly influence the overall cost of meeting greenhouse gas limits. This paper examines the potential benefit of reduced technology cost by analyzing the case of the Lieberman-Warner Climate Security Act of 2007 (S.2191). This act had a goal of reducing national carbon emissions in 2050 to levels 72 percent below 2006 emission levels. In April 2008, the U.S. Department of Energy, Energy Information Administration (EIA) published an analysis of the effects of S.2191 on the U.S. energy sector. This report presents a similar analysis: both analyses examined the impacts of S.2191, and both used versions of the National Energy Modeling System. The analysis reported here used modified technology assumptions to reflect U.S. Department of Energy, Office of Energy Efficiency and Renewable Energy (EERE) program goals. The results show that achieving EERE program goals could reduce the cost of meeting greenhouse gas limits, reduce the cost of renewable electricity generation and biofuels, and reduce energy intensity.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Overcoming Codes and Standards Barriers to Innovations in Building Energy Efficiency

In this journal article, the authors discuss approaches to overcoming building code barriers to energy-efficiency innovations in home construction. Building codes have been a highly motivational force for increasing the energy efficiency of new homes in the United States in recent years. But as quickly as the codes seem to be changing, new products are coming to the market at an even more rapid pace, sometimes offering approaches and construction techniques unthought of when the current code was first proposed, which might have been several years before its adoption by various jurisdictions. Due to this delay, the codes themselves can become barriers to innovations that might otherwise be helping to further increase the efficiency, comfort, health or durability of new homes. . The U.S. Department of Energy’s Building America, a program dedicated to improving the energy efficiency of America’s housing stock through research and education, is working with the U.S. housing industry through its research teams to help builders identify and remove code barriers to innovation in the home construction industry. The article addresses several approaches that builders use to achieve approval for innovative building techniques when code barriers appear to exist.

Building America↗

Accuracy of HVAC Load Predictions: Validation of EnergyPlus and DOE-2 using FLEXLAB Measurements

The aim of the project reported here was to better understand the level of accuracy of three building energy simulation (BES) engines (‘engines’) — EnergyPlus™, DOE-2.1e, and DOE-2.2 — by identifying and investigating significant deviations between the performance predicted by these engines and actual performance as measured in the FLEXLAB® test facility at Lawrence Berkeley National Laboratory (LBNL). The specific test conditions included some of those prescribed in ANSI/ASHRAE Standard 140 - Standard Method of Test for the Evaluation of Building Energy Analysis Computer Programs. Detailed measurements of FLEXLAB performance, including indoor temperatures and heat fluxes and air-flow and water flow rates and temperatures in the Heating, Ventilating and Air Conditioning (HVAC) system, together with hourly weather data, were recorded and used in analyzing the simulation results from EnergyPlus v8.8, DOE-2.2 v3.65 and DOE-2.1e v127. These engines are commonly used in the United States for building energy code compliance, federal, state, and utility incentives programs, as well as energy efficient design of new buildings and energy retrofit of existing buildings. Seven conventional overhead mixing ventilation scenarios were tested and each engine was found to have a similar level of agreement with the measurements of space-level heating and sensible cooling loads. These results provide useful information regarding the accuracy of these engines in predicting the cooling and heating load elements of whole building energy performance. This information is intended for practitioners who are concerned about transitioning between simulation tools with different engines and for managers of utility programs leveraging these tools for evaluating and/or projecting measure savings to be incentivized under their programs. The results of the comparisons of simulated and measured performance indicate that the predictions from all three engines are not significantly different. The 24-hour average value of the absolute mean bias indicates the likely magnitude of the error in any particular case. The average mean bias is reduced by cancelation of overprediction in one case by underprediction in another. The daytime absolute mean biases, which may be more important for both energy performance and occupant comfort, are ~6%, presumably because of the greater complexity involved in simulating in the presence of solar radiation. EnergyPlus typically overpredicts the cooling load and/or underpredicts the heating load by ~1.5% and the DOE-2 engines typically underpredict the cooling load by approximately the same amount. The Root Mean Square Error is relatively more sensitive to shorter term variations in the difference between predicted and measured loads; the three engines have similar values, ~10%, suggesting that the uncertainties in their predictions of peak loads may also be similar in magnitude. The implication of these results is that users, both designers and program analysts, can use EnergyPlus, DOE-2.1e, or DOE-2.2 to model conventional commercial buildings equipped with overhead mixing ventilation with a similar level of confidence. Further work is required to better understand the variability in the level of agreement between the engine predictions and FLEXLAB measurements, where a particular engine will agree well with FLEXLAB in some cases and not so well in others and another engine will agree or disagree in different cases. As the sources of this variability are identified and eliminated or reduced significantly, it is recommended that the experimental capabilities and methods developed in the study reported here should be applied to validating heating and cooling load calculations for spaces with different types of furniture and miscellaneous loads. These methods should then be applied to low energy space conditioning systems in EnergyPlus including, in particular, radiant slab and radiant ceiling panel cooling and heating systems and ‘mixed mode’ systems that combine mechanical cooling and natural ventilation systems, focusing on controls, including control of thermal mass. The work reported here addresses the conventional method of heating and cooling occupied spaces; other methods, such as the use of radiant heating and cooling systems have the potential to provide equivalent occupant comfort, or better, with lower energy consumption. These systems are addressed more explicitly in EnergyPlus but there is a need for empirical validation to give users the same level of confidence in modeling these systems that they have, or should have, in modeling conventional systems, based on the results presented here.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy Efficiency and Renewable Energy Research, Development, and Deployment in Meeting Greenhouse Gas Mitigation Goals: The Case of the Lieberman-Warner Climate Security Act of 2007 (S.2191)

The U.S. federal government is considering actions to reduce greenhouse gas emissions. Renewable energy and energy efficiency technologies could help reduce greenhouse gas emissions, so the cost of these technologies could significantly influence the overall cost of meeting greenhouse gas limits. This paper examines the potential benefit of reduced technology cost by analyzing the case of the Lieberman-Warner Climate Security Act of 2007 (S.2191). This act had a goal of reducing national carbon emissions in 2050 to levels 72 percent below 2006 emission levels. In April 2008, the U.S. Department of Energy, Energy Information Administration (EIA) published an analysis of the effects of S.2191 on the U.S. energy sector. This report presents a similar analysis: both analyses examined the impacts of S.2191, and both used versions of the National Energy Modeling System. The analysis reported here used modified technology assumptions to reflect U.S. Department of Energy, Office of Energy Efficiency and Renewable Energy (EERE) program goals. The results show that achieving EERE program goals could reduce the cost of meeting greenhouse gas limits, reduce the cost of renewable electricity generation and biofuels, and reduce energy intensity.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Summary of Prioritized Research Opportunities: Building America Program Planning Meeting, Washington, D.C., November 2-4, 2010

This report outlines the results of brainstorming sessions conducted at the Building America Fall 2010 planning meeting, in which research teams and national laboratories identified key research priorities to incorporate into multi-year planning, team research agendas, expert meetings, and technical standing committees.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Boston Architectural College Urban Sustainability Initiative

The Boston Architectural College's Urban Sustainability initiative is a demonstration project as defined by the National Energy Technology Laboratory. BAC's proposed project with the U.S. Department of Energy - NETL, is a large part of that overall initiative. The BAC's Urban Sustainability Initiative is a multi-part project with several important goals and objectives that will have a significant impact on the surrounding neighborhood including: energy conservation, reduction of storm water runoff, generation of power through alternative energy sources, elimination/reduction of BAC carbon footprint, and to create a vehicle for ongoing public outreach and education. Education and outreach opportunities will serve to add to the already comprehensive Sustainability Design courses offered at BAC relative to energy savings, performance and conservation in building design. At the finish of these essential capital projects there will be technical materials created for the education of the design, sustainability, engineering, community development and historic preservation communities, to inform a new generation of environmentally-minded designers and practitioners, the city of Boston and the general public. The purpose of the initiative, through our green renovations program, is to develop our green alley projects and energy saving renovations to the BAC physical plant, to serve as a working model for energy efficient design in enclosed 19th century and 20th century urban sites and as an educational laboratory for teaching ecological and sustainable technologies to students and the public while creating jobs. The scope of our project as it relates to the BAC and the U.S. Department of Energy- NETL combined efforts includes: Task I of the project is Phase II (Green Alley). Task I encompasses various renovation activities that will demonstrate the effectiveness of permeable paving and ground water recharge systems. It will aid in the reduction of storm water runoff into the Charles River Basin in one of its most significantly polluted sections and, will provide a green renovation mechanism for the redirected storm water of a public alley way. This activity is designed to improve the quality of water recharging the ground water and protecting the vulnerable wood pilings under many of the historic masonry buildings in Boston's Back Bay. Sustainable design research and system monitoring opportunities will also be incorporated, providing ongoing tools for public outreach and education through innovative signage and "virtual tour" technology. The monitoring will include a "building performance dash board" that reflects real time operating conditions and improvements in environmental and economic performance to be prominently displayed on the face of our 320 Newbury Street building (approximately 1.5 million people walk by annually). The project site and demonstration area is located at the rear of 951 Boylston Street, Boston, MA 02115 and the parking area adjacent to Public Alley #444 in Boston's historic Back Bay. Task II of the project is Geothermal Solution. This task involves the installation of approximately seven Geothermal wells which will tap into the earth's constant underground temperatures to provide air-conditioning and heating for BAC facilities. The environmentally friendly geothermal system uses no fossil fuel, produces no emissions and runs silently, providing a sustainable model for commercial and residential buildings throughout Boston. Ultimately the combination of this project and other projects will assist in making the BAC "carbon-neutral", and could generate enough additional energy to provide free power to the Engine 33 and Ladder 15 Firehouse located at 941 Boylston Street. The project is located at the rear of 951 Boylston Street, Boston, MA 02115 and the parking area adjacent to Public Alley #444 in Boston's historic Back Bay. Task III of the project is the Sustainability Design Curriculum at the BAC. The BAC is the nation’s largest independent, multi-disciplinary college of spatial design, and a leader in sustainable design education. The Sustainabiltiy Design program, in particular, focuses on energy efficiency,energy performance, energy modeling, energy and air quality principles, green building, renewable energy alternatives and much more. Additionally, the Urban Sustainability Initiative has an objective of providing courses relative to the BAC's demonstration project with DOE, the project’s period of performance activities, subsequent performance data and anticipated sustainability teaching tools. In keeping with BAC's practice based curriculum, students have been involved in the discussion and planning of this project since its inception and sustainability issues have become a part of other programs throughout the college as well. Students will continue to benefit from this hands-on learning opportunity. The project is located at 320 Newbury Street Boston, MA 02115. Task IV of the project is Program Management and Reporting. This task will involve BAC's oversight and general management of the entire project including subcontract administration, contracts administration, technical and financial reporting, design and renovation assistance, other deliverables in accordance with the Federal Assistance reporting Checklist and other contractual obligations and provisions.

15 GEOTHERMAL ENERGY↗

Energy Assessments under the Top 10,000 Program - A Case Study for a Steel Mill in China

One of the largest energy-savings programs for the Chinese industrial sector was the Top-1,000 Program, which targeted the 1,000 largest industrial enterprises in China. This program was launched in 2006, implemented through 2010, and covered 33% of national energy usage. Because of the success of the Top-1000 initiative, the program has now been expanded to the Top-10,000 program in the 12th Five-Year Plan period (2011-2015). The Top-10,000 program covers roughly 15,000 industrial enterprises, or about two-thirds of China s total energy consumption. Implementing energy audit systems and conducting industrial energy efficiency assessments are key requirements of the Top-10,000 program. Previous research done by Lawrence Berkeley National Laboratory (LBNL) has shown that there is a significant potential for improvement in energy assessment practices and applications in China. Issues such as lack of long term policy mechanisms, insufficient motivation for industrial enterprises, limited technical scope of energy assessments, and lack of systematic standardization have been identified. Through the support of the U.S. Department of Energy (DOE) and the U.S. State Department (with additional co-funding from the Energy Foundation China), LBNL, Oak Ridge National Laboratory, the Institute for Sustainable Communities (ISC), and DOE Energy Experts worked collaboratively with Chinese local organizations and conducted a series of industrial energy efficiency assessment demonstrations in selected Chinese industrial plants. The project aimed to not only introduce standardized methodologies and tools for energy assessments, but also to bring the systems approach for energy system analysis to the Top 10,000 enterprises. Through the project, five energy system assessments were conducted, and more than 300 Chinese experts from local energy conservation centers, universities, research organizations, energy service companies, and plant engineers were trained. This paper begins by introducing China s national energy intensity and carbon intensity reduction targets. Then, this paper explains the development of Top 10,000 program, including program requirements, the method for target allocation, key supporting policies, as well as challenges in implementing the program. By focusing on a process heating energy system assessment conducted in a Chinese steel mill, this paper presents an example of an energy system assessment conducted on steel reheating furnaces, including overall energy efficiency levels, areas of heat loss, and the potential for energy savings. In addition, the paper provides energy-savings recommendations that were identified during the assessment, as well as potential energy and energy costs savings. To conclude, this paper presents key findings that could further improve the Top 10,000 program by implementing a systems approach for energy assessments.

China Energy Efficiency↗

Energy Efficient Mobility Systems 2018 Annual Progress Report

Energy Efficient Mobility Systems (EEMS) Program activities during FY 2018 focused on analytical research to understand the impacts that new mobility technologies and services will have at the vehicle, traveler, and overall transportation system-level. This research included the development of vehicle and transportation system simulation models and tools to evaluate the complex interactions among the various actors within the mobility landscape, analysis of empirical data to characterize which solutions may provide the largest benefits, and development of new control systems and algorithms that use vehicle connectivity and automation to improve the performance and efficiency of individual vehicles as well as the overall traffic system This document presents a brief overview of the EEMS Program and documents progress and results for projects within four of the five EEMS activity areas: (1) the SMART (Systems and Modeling for Accelerated Research in Transportation) Mobility Lab Consortium, (2) High Performance Computing and Big Data Solutions for Mobility Data, (3) Advanced R&D Projects conducted by industry and academia, and (4) Core Modeling, Simulation, and Evaluation, Similarly, the remaining EEMS activity area – (5) Living Labs (managed under VTO’s Technology Integration Program). Each of the individual progress reports provide a project overview and highlights of the technical results.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Capturing Energy Efficiency in Residential Real Estate Transactions

This report provides examples of programs across the U.S. that are successfully engaging the real estate community and overcoming barriers to valuing energy efficiency in the home resale process. The paper recommends actions that efficiency real estate professionals can take to facilitate the availability and use of reliable energy information at point of sale.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Reducing Transaction Costs for Energy Efficiency Investments and Analysis of Economic Risk Associated With Building Performance Uncertainties: Small Buildings and Small Portfolios Program

The small buildings and small portfolios (SBSP) sector face a number of barriers that inhibit SBSP owners from adopting energy efficiency solutions. This pilot project focused on overcoming two of the largest barriers to financing energy efficiency in small buildings: disproportionately high transaction costs and unknown or unacceptable risk. Solutions to these barriers can often be at odds, because inexpensive turnkey solutions are often not sufficiently tailored to the unique circumstances of each building, reducing confidence that the expected energy savings will be achieved. To address these barriers, NREL worked with two innovative, forward-thinking lead partners, Michigan Saves and Energi, to develop technical solutions that provide a quick and easy process to encourage energy efficiency investments while managing risk. The pilot project was broken into two stages: the first stage focused on reducing transaction costs, and the second stage focused on reducing performance risk. In the first stage, NREL worked with the non-profit organization, Michigan Saves, to analyze the effects of 8 energy efficiency measures (EEMs) on 81 different baseline small office building models in Holland, Michigan (climate zone 5A). The results of this analysis (totaling over 30,000 cases) are summarized in a simple spreadsheet tool that enables users to easily sort through the results and find appropriate small office EEM packages that meet a particular energy savings threshold and are likely to be cost-effective.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Selling an Energy Efficiency Loan Portfolio in Oregon: Resale of the Craft3 loan portfolio to Self-Help Credit Union

Under the Clean Energy Works (CEW) program, Craft3 developed a loan product that widened access to financing for homeowners, offered long term funding, and collected repayments through the customer?s utility bill. The program?s success led Craft3 to pursue the sale of the loan portfolio to both mitigate its own risks and replenish funds for lending. This sale breaks new ground for energy efficiency finance and is notable as it was completed even with many novel program design elements. It replenished Craft3?s program capital and uncovered some valuable lessons that may facilitate future transactions. However, the lack of data history and the unproven nature of the loan portfolio meant that Craft3 had to limit the risk of losses to Self-Help, the purchaser of the portfolio. It remains to be seen whether this experience will pave the way for more sales of on-bill energy efficiency loan portfolios. This case study illustrates how certain program design decisions can sometimes both facilitate programmatic objectives and possibly present challenges for the sale of a portfolio of energy efficiency loans.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

2011 Residential Energy Efficiency Technical Update Meeting Summary Report: Denver, Colorado - August 9-11, 2011

This report provides an overview of the U.S. Department of Energy Building America program's Summer 2011 Residential Energy Efficiency Technical Update Meeting. This meeting was held on August 9-11, 2011, in Denver, Colorado, and brought together more than 290 professionals representing organizations with a vested interest in energy efficiency improvements in residential buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The Role of Ir in Ternary Rh-Based Catalysts for Syngas Conversion to C2+ Oxygenates

Transition metal modified Rh-catalysts can be used for converting syngas (CO+H2) into C2+ oxygenates. It has been found that Mn has a favorable effect in the selectivity towards oxygenates, while addition of Ir to the binary Rh-Mn catalysts significantly increases the space-time yield of C2+ oxygenates. In this paper, we use quantum mechanical calculations to investigate the distribution of promoter sites within Rh rich nanoparticles and their role in the conversion of syngas towards ethanol. This work was supported by the U.S. Department of Energy (DOE), Office of Energy Efficiency and Renewable Energy Biomass Program. The Pacific Northwest National Laboratory (PNNL) is operated by Battelle for the DOE under Contract DE-AC05-76RL01830. A portion of the research was performed in the Environmental Molecular Sciences Laboratory (EMSL), a national science user facility sponsored by the Department of Energy’s Office of Biological and Environmental Research located at PNNL.

DFT models↗