Search NASA⌕ Search

SEARCH · Search NASA

Results for “Equivalent”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

General sum rules for WW scattering in Higgsless models: Equivalence theorem and deconstruction identities

We analyze inelastic 2{yields}2 scattering amplitudes for gauge bosons and Nambu-Goldstone bosons in deconstructed Higgsless models. Using the (KK) equivalence theorem in 4D (5D), we derive a set of general sum rules among the boson masses and multiboson couplings that are valid for arbitrary deconstructed models. Taking the continuum limit, our results naturally include the 5D Higgsless model sum rules for arbitrary 5D geometry and boundary conditions; they also reduce to the elastic sum rules when applied to the special case of elastic scattering. For the case of linear deconstructed Higgsless models, we demonstrate that the sum rules can also be derived from a set of general deconstruction identities and completeness relations. We apply these sum rules to the deconstructed 3-site Higgsless model and its extensions; we show that in 5D ignoring all higher KK modes (n>1) is inconsistent once the inelastic channels become important. Finally, we discuss how our results generalize beyond the case of linear Higgsless models.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Note on the equivalence of a barotropic perfect fluid with a k-essence scalar field

In this brief report, we obtain the necessary and sufficient condition for a class of noncanonical single scalar field models to be exactly equivalent to barotropic perfect fluids, under the assumption of an irrotational fluid flow. An immediate consequence of this result is that the nonadiabatic pressure perturbation in this class of scalar field systems vanishes exactly at all orders in perturbation theory and on all scales. The Lagrangian for this general class of scalar field models depends on both the kinetic term and the value of the field. However, after a field redefinition, it can be effectively cast in the form of a purely kinetic k-essence model.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Probing the Goldstone equivalence theorem in heavy weak doublet decays

We explore here the decays from heavy Higgsino-like weak doublets into Z , h bosons and missing particles. When pair-produced at the LHC, the subsequent Z , h → ℓ ℓ , b b ¯ decays in the doublet decay cascade can yield 4 ℓ , 2 ℓ 2 b and 4 b + E T + j ( s ) final states. Mutual observation of any two of these channels would provide information on the associated doublets’ decay branching fractions into a Z or h , thereby probing the Goldstone equivalence relation, shedding additional light on the Higgs sector of beyond the Standard Model theories and facilitating the discrimination of various contending models, in turn. We compare the Z / h decay ratio expected in the minimal supersymmetric model, the next-to-minimal supersymmetric model (NMSSM)and a minimal singlet-doublet dark matter model. Furthermore, we conduct a full Monte Carlo analysis of the prospects for detecting the targeted final states during 14 TeV running of the LHC in the context of a representative NMSSM benchmark model.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Converting three-space matrices to equivalent six-space matrices for Delone scalars in S 6

The transformations from the primitive cells of the centered Bravais lattices to the corresponding centered cells have conventionally been listed as three-by-three matrices that transform three-space lattice vectors. Using those three-by-three matrices when working in the six-dimensional space of lattices represented as Selling scalars as used in Delone (Delaunay) reduction, one could transform to the three-space representation, apply the three-by-three matrices and then back-transform to the six-space representation, but it is much simpler to have the equivalent six-by-six matrices and apply them directly. The general form of the transformation from the three-space matrix to the corresponding matrix operating on Selling scalars (expressed in space S 6 ) is derived, and the particular S 6 matrices for the centered Delone types are listed. (Note: in his later publications, Boris Delaunay used the Russian version of his surname, Delone.)

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A Machine Learning based Approach of Estimating Equivalent Circuit Model Parameters at Different SoCs of Li-ion Batteries from Voltage Relaxation

Abstract: In this study, an approach of estimating the equivalent circuit model (ECM) parameters for Li-ion batteries (LIBs) is proposed based on the voltage value at different intervals while relaxing the LIB after discharge. The typical approach for estimating ECM parameters of a LIB is to conduct electrochemical impedance spectroscopy (EIS) measurements at different frequencies and fit them to a predefined circuit model, which requires additional measuring arrangements and specialized devices. The proposed methodology utilizes four different voltages at 0s, 60s, 360s, and 1800s alongside the specific state of charge (SoC) value for a specific constant discharge current value of ~1C until the relaxation stage to train and evaluate three regression-based machine learning models— Support Vector Regression (SVR), Extreme Gradient Boosting (XGBoost), and Gaussian Process Regression (GPR)—for estimating the ECM parameters of the selected model. Bayesian optimization is employed for hyperparameter tuning to achieve optimal performance for all the regressor models, among which, the GPR provided the best performance with the root-mean-squared error (RMSE) of less than 4x10-4 on average for the resistive components and less than 0.27 for capacitive components with excellent R2 scores. The simplicity of the approach enables it to eliminate the need for sophisticated measuring equipment and computation power.

Sagar, Md. Samiul [The University of Alabama (UA)]↗

Ground Vehicle Generalized Forces and Moment Governor Design Via Noncertainty-Equivalent Adaptive Prescribed Performance Control

Torque-vectoring technology demonstrates great potential in improving the safety and performance of ground vehicles. In this paper, a novel generalized forces and moment governor for torque vectoring is suggested. The proposed solution strategically combines prescribed performance control, noncertainty equivalent adaptive control design, and a smooth projection operator. The main advantage of the proposed control strategy lies in its capability to guarantee both the transient performance and prompt recovery of the desired deterministic behavior of the closed-loop adaptive system, even in the presence of parametric uncertainties. ASM simulation results are presented to validate the efficacy of the proposed generalized forces and moment governor and to demonstrate its superiority over a baseline solution.

Zhou, Xingyu↗

Measurement-based Power System Dynamic Model Reduction Using ARX Equivalents

The increasing complexity of power system has made it difficult to simulate large-scale power system in detail. Therefore, to improve computational efficiency, model reduction techniques has been applied to reduce the external area and focus on the dynamics of the internal area. This paper proposes a measurement-based model reduction method which reduces the external system by replacing external system with ARX equivalents. The modeled transfer function parameters are obtained using system identification approach. Case studies on the NPCC system and EI system are carried out. Results show that the proposed reduction method can effectively retain the dynamic behavior of the study area while mitigating computation burden.

Jiang, Zhihao↗

Battery Equivalent Model for Residential HVAC

Flexible loads, especially heating, ventilation, and air-conditioning (HVAC) systems can be used to provide a battery-like service to the power grid by varying their demand up and down over a baseline. Recent work has reported that the round-trip efficiency for providing grid services with HVAC systems can be close to 1. Inspired by this promising result, in this work, we rigorously develop a battery equivalent model (BEM) for residential HVAC systems. Relying only on typically available data, the proposed BEM will bridge the observability and controllability gaps between utility companies and customers. The proposed BEM will enable the utility companies to manage the flexible HVAC devices as easy as charging/discharging the conventional energy storage devices. Validated physics-based models are used to train the BEM, whose prediction accuracy is illustrated through a simulation study.

Dong, Jin↗

A Two-Dimensional Non-Linear Magnetic Equivalent Circuit Model to Facilitate the Preliminary Design of a Normal Conducting Quadrupole

Normal conducting quadrupoles have been used to focus charged particle beams in synchrotrons, beam transfer lines, medical linacs, etc. for a long time. Optimization techniques based on analytical expressions combined with the use of a numerical field analysis tool exist in the literature for the design of an optimal pole tip shape. However, the initial shape and dimensions of the remaining yoke (including the pole itself and yoke base that act as the return path) are usually less well defined. This article discusses a design methodology for a normal conducting quadrupole based on a two-dimensional magnetic equivalent circuit. Here, this approach considers the geometry of the entire magnet and the non-linear behavior of the yoke material, thereby eliminating the initial iterations. The design outcome of this exercise serves as a competent starting point and can then be used to refine the pole tip, pole taper, yoke size, and add other geometrical features to achieve the required field quality, gradient, coil considerations, etc. by employing a finite element analysis tool. An example design study to demonstrate the proposed methodology is presented.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

An Equivalent Time-Variant Storage Model to Harness EV Flexibility: Forecast and Aggregation

The demand for vehicle charging will necessitate large investments in power distribution, transmission, and generation. However, this demand is often also flexible in time, and can be actively managed to reduce the needed investments, and to better integrate renewable electricity. Harnessing this flexibility requires forecasting and controlling electric vehicle (EV) charging at thousands of stations. In this work, we address the problem of forecasting and management of the aggregate flexible demand from tens to thousands of EV supply equipment (EVSEs). First, it presents an equivalent time-variant storage model for flexible demand at an aggregation of EVSEs. The proposed model is generalizable to different markets, and also to different flexible loads. Model parameters representing multiple EVSEs can be easily aggregated by summation, and forecasted using autoregressive models. The forecastability of uncontrolled demand and storage parameters is evaluated using data from 1341 nonresidential EVSEs located in Northern California. The median coefficient of variation is as low as 24% for the forecast of uncontrolled demand at the highest aggregation and 10-15% for the storage parameters. The benefits of aggregation and forecastability are demonstrated using an energy arbitrage scenario. Purchasing energy day ahead is less expensive than in the real-time market, but relies on a uncertain forecast of charging availability. The results show that the forecastability significantly improves for larger aggregations. This helps the aggregator make a better forecast, and decreases the cost of charging in comparison to an uncontrolled case by 60% with respect to an oracle scenario.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Unchanged carbon balance driven by equivalent responses of production and respiration to climate change in a mixed‐grass prairie

Abstract Responses of grassland carbon (C) cycling to climate change and land use remain a major uncertainty in model prediction of future climate. To explore the impacts of global change on ecosystem C fluxes and the consequent changes in C storage, we have conducted a field experiment with warming (+3 °C), altered precipitation (doubled and halved), and annual clipping at the end of growing seasons in a mixed‐grass prairie in Oklahoma, USA , from 2009 to 2013. Results showed that although ecosystem respiration ( ER ) and gross primary production ( GPP ) negatively responded to warming, net ecosystem exchange of CO 2 ( NEE ) did not significantly change under warming. Doubled precipitation stimulated and halved precipitation suppressed ER and GPP equivalently, with the net outcome being unchanged in NEE . These results indicate that warming and altered precipitation do not necessarily have profound impacts on ecosystem C storage. In addition, we found that clipping enhanced NEE due to a stronger positive response of GPP compared to ER , indicating that clipping could potentially be an effective land practice that could increase C storage. No significant interactions between warming, altered precipitation, and clipping were observed. Meanwhile, we found that belowground net primary production ( BNPP ) in general was sensitive to climate change and land use though no significant changes were found in NPP across treatments. Moreover, negative correlations of the ER / GPP ratio with soil temperature and moisture did not differ across treatments, highlighting the roles of abiotic factors in mediating ecosystem C fluxes in this grassland. Importantly, our results suggest that belowground C cycling (e.g., BNPP ) could respond to climate change with no alterations in ecosystem C storage in the same period.

Xu, Xia↗

Comparison of on-shot, in-tank, and equivalent-target-plane measurements of the OMEGA Laser System focal spot

The newly developed full-beam-in-tank (FBIT) diagnostic has the capability to characterize multiple beamlines in the target chamber. In addition to measuring multiple beams, we can obtain measurements of the step-by-step changes to achieve smoothing by spectral dispersion (SSD), the SSD kernel, and SSD synchronization. Since other existing diagnostics are all located upstream of the target chamber, this diagnostic can be used to explore a propagating beam through the final optics assembly. In this work, we investigate current discrepancies between laser diagnostics and experimental results by comparing results of on-shot direct measurements using FBIT and the equivalent-target-plane diagnostic.

47 OTHER INSTRUMENTATION↗

Evaluation of an a-Si EPID in direct detection configuration as a water-equivalent dosimeter for transit dosimetry

Purpose: A major problem associated with amorphous silicon (a-Si) electronic portal imaging devices (EPIDs) for transit dosimetry is the presence of a phosphor layer, which can introduce large deviations from water-equivalent behavior due to energy-dependent response and visible light scattering. In this study, an amorphous silicon EPID was modified to a direct detection configuration by removing the phosphor layer, and the accuracy of using it for transit dosimetry measurements was investigated for 6 and 18 MV treatment beams by comparison to ion-chamber in water measurements. Methods: Solid water and copper were both evaluated as buildup materials. Using the optimum buildup thickness in each case, effects of changes in radiation field size, source to detector distance, and patient/phantom thickness were investigated by comparison to reference measurements made by an ionization chamber on the central axis. The off-axis response of the imager was also investigated by comparison of EPID image profiles to dose profiles obtained by a scanning ionization chamber in a water tank with various thicknesses of slab phantoms, and an anthropomorphic phantom in the beam using Gamma evaluation (3%, 3 mm criteria). The imaging characteristics of the direct EPID were investigated by comparison to a commercial EPID using QC3V phantom, and by taking images of an anthropomorphic pelvic phantom containing fiducial gold markers. Results: Either 30 mm of solid water or 3.3 mm of copper were found to be the most suitable buildup thicknesses with solid water providing more accurate results. Using solid water buildup, the EPID response compared to the reference dosimeter within 2% for all conditions except phantom thicknesses larger than 25 cm in 6 MV beams, which was up to 6.5%. Gamma evaluation results comparing EPID profiles and reference ionization chamber profiles showed that for 6 and 18 MV beams, at least 91.8% and 90.9% of points had a Gamma<1 for all phantoms, respectively. But using copper buildup, the EPID response had more discrepancies from the ionization chamber reference measurements, including: More than 2% difference for small air gaps using 6 MV beams, up to 8% difference for phantom thicknesses larger than 25 cm in 6 MV beams, and large differences (up to 9.3%) for increasing phantom thicknesses in 18 MV beams. The percentage of points with Gamma<1 with copper buildup were at least 96.6% and 99.8% in 6 and 18 MV beams, respectively. Conclusions: The direct EPID performs as an ion-chamber detector for transit dosimetry applications in all geometries studied except for small discrepancies at 6 MV for thick phantoms. This can be ameliorated by the calibration of the EPID to dose at an intermediate phantom thickness. The major current limitation of the direct EPID is poor quality of images compared with the clinical configuration, which could be overcome by a method to interchange between imaging and dosimetry setups.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Water equivalent path length measurement in proton radiotherapy using time resolved diode dosimetry

Purpose: To verify water equivalent path length (WEPL) before treatment in proton radiotherapy using time resolved in vivo diode dosimetry. Methods: Using a passively scattered range modulated proton beam, the output of a diode driving a fast current-to-voltage amplifier is recorded at a number of depths in a water tank. At each depth, a burst of overlapping single proton pulses is observed. The rms duration of the burst is computed and the resulting data set is fitted with a cubic polynomial. Results: When the diode is subsequently set to an arbitrary depth and the polynomial is used as a calibration curve, the ''unknown'' depth is determined within 0.3 mm rms. Conclusions: A diode or a diode array, placed (for instance) in the rectum in conjunction with a rectal balloon, can potentially determine the WEPL at that point, just prior to treatment, with submillimeter accuracy, allowing the beam energy to be adjusted. The associated unwanted dose is about 0.2% of a typical single fraction treatment dose.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-T-403: Measurement of the Neutron Ambient Dose Equivalent From the TrueBeam Linac Head and Varian 2100 Clinac

Purpose: High-energy x-ray therapy produces an undesirable source of stray neutron dose to healthy tissues, and thus, poses a risk for second cancer induction years after the primary treatment. Hence, the purpose of this study was to measure the neutron ambient dose equivalent, H*(10), produced from the TrueBeam and Varian 2100 linac heads, respectively. Of particular note is that there is no measured data available in the literature on H*(10) production from the TrueBeam treatment head. Methods: Both linacs were operated in flattening filter mode using a 15 MV x-ray beam on TrueBeam and an 18 MV x-ray beam for the Varian 2100 Clinac with the jaws and multileaf collimators in the fully closed position. A dose delivery rate of 600 MU/min was delivered on the TrueBeam and the Varian 2100 Clinac, respectively and the H*(10) rate was measured in triplicate using the WENDI-2 detector located at multiple positions including isocenter and longitudinal (gun-target) to the isocenter. Results: For each measurement, the H*(10) rate was relatively constant with increasing distance away from the isocenter with standard deviations on the order of a tenth of a mSv/h or less for the given beam energy. In general, fluctuations in the longitudinal H*(10) rate between the anterior-posterior couch directions were approximately a percent for both beam energies. Conclusion: Our preliminary results suggest an H*(10) rate of about 30 mSv/h (40 mSv/h) or less for TrueBeam (Varian Clinac 2100) for all measurements considered in this study indicating a relatively low contribution of produced secondary neutrons to the primary therapeutic beam.

60 APPLIED LIFE SCIENCES↗

TH-C-19A-01: Analytic Design Method to Make a 2D Planar, Segmented Ion Chamber Water-Equivalent for Proton Dose Measurements

Purpose: Quality Assurance (QA) measurements of proton therapy fields must accurately measure steep longitudinal dose gradients as well as characterize the dose distribution laterally. Currently, available devices for two-dimensional field measurements perturb the dose distribution such that routine QA measurements performed at multiple depths require multiple field deliveries and are time consuming. Methods: A design procedure for a two-dimensional detector array is introduced whereby the proton energy loss and scatter are adjusted so that the downstream dose distribution is maintained to be equivalent to that which would occur in uniform water. Starting with the design for an existing, functional two-dimensional segmented ion chamber prototype, a compensating material is introduced downstream of the detector to simultaneously equate the energy loss and lateral scatter in the detector assembly to the values in water. An analytic formalism and procedure is demonstrated to calculate the properties of the compensating material in the general case of multiple layers of arbitrary material. The resulting design is validated with Monte Carlo simulations. Results: With respect to the specific prototype design considered, the results indicate that a graphite compensating layer of the proper dimensions can yield proton beam range perturbation less than 0.1mm and beam sigma perturbation less than 2% across the energy range of therapeutic proton beams. Conclusion: We have shown that, for a 2D gas-filled detector array, a graphite-compensating layer can balance the energy loss and multiple Coulomb scattering relative to uniform water. We have demonstrated an analytic formalism and procedure to determine a compensating material in the general case of multiple layers of arbitrary material. This work was supported by the US Army Medical Research and Materiel Command under Contract Agreement No. DAMD17-W81XWH-04-2-0022. Opinions, interpretations, conclusions and recommendations are those of the author and are not necessarily endorsed by the US Army.

07 ISOTOPE AND RADIATION SOURCES↗

SU-E-J-141: Activity-Equivalent Path Length Approach for the 3D PET-Based Dose Reconstruction in Proton Therapy

Purpose: Ion beam therapy is sensitive to uncertainties from treatment planning and dose delivery. PET imaging of induced positron emitter distributions is a practical approach for in vivo, in situ verification of ion beam treatments. Treatment verification is usually done by comparing measured activity distributions with reference distributions, evaluated in nominal conditions. Although such comparisons give valuable information on treatment quality, a proper clinical evaluation of the treatment ultimately relies on the knowledge of the actual delivered dose. Analytical deconvolution methods relating activity and dose have been studied in this context, but were not clinically applied. In this work we present a feasibility study of an alternative approach for dose reconstruction from activity data, which is based on relating variations in accumulated activity to tissue density variations. Methods: First, reference distributions of dose and activity were calculated from the treatment plan and CT data. Then, the actual measured activity data were cumulatively matched with the reference activity distributions to obtain a set of activity-equivalent path lengths (AEPLs) along the rays of the pencil beams. Finally, these AEPLs were used to deform the original dose distribution, yielding the actual delivered dose. The method was tested by simulating a proton therapy treatment plan delivering 2 Gy on a homogeneous water phantom (the reference), which was compared with the same plan delivered on a phantom containing inhomogeneities. Activity and dose distributions were were calculated by means of the FLUKA Monte Carlo toolkit. Results: The main features of the observed dose distribution in the inhomogeneous situation were reproduced using the AEPL approach. Variations in particle range were reproduced and the positions, where these deviations originated, were properly identified. Conclusions: For a simple inhomogeneous phantom the 3D dose reconstruction from PET-activity induced by proton beams was shown to be feasible.

60 APPLIED LIFE SCIENCES↗

WE-EF-303-10: Single- Detector Proton Radiography as a Portal Imaging Equivalent for Proton Therapy

Purpose: In proton therapy, patient alignment is of critical importance due to the sensitivity of the proton range to tissue heterogeneities. Traditionally proton radiography is used for verification of the water-equivalent path length (WEPL), which dictates the depth protons reach. In this work we propose its use for alignment. Additionally, many new proton centers have cone-beam computed tomography in place of beamline X-ray imaging and so proton radiography offers a unique patient alignment verification similar to portal imaging in photon therapy. Method: Proton radiographs of a CIRS head phantom were acquired using the Beam Imaging System (BIS) (IBA, Louvain-la-Neuve) in a horizontal beamline. A scattered beam was produced using a small, dedicated, range modulator (RM) wheel fabricated out of aluminum. The RM wheel was rotated slowly (20 sec/rev) using a stepper motor to compensate for the frame rate of the BIS (120 ms). Dose rate functions (DRFs) over two RM wheel rotations were acquired. Calibration was made with known thicknesses of homogeneous solid water. For each pixel the time width, skewness and kurtosis of the DRFs were computed. The time width was used to compute the object WEPL. In the heterogeneous phantom, the excess skewness and excess kurtosis (i.e. difference from homogeneous cases) were computed and assessed for suitability for patient set up. Results: The technique allowed for the simultaneous production of images that can be used for WEPL verification, showing few internal details, and excess skewness and kurtosis images that can be used for soft tissue alignment. These latter images highlight areas where range mixing has occurred, correlating with phantom heterogeneities. Conclusion: The excess skewness and kurtosis images contain details that are not visible in the WET images. These images, unique to the time-resolved proton radiographic method, could be used for patient set up according to soft tissues.

60 APPLIED LIFE SCIENCES↗