Search NASA⌕ Search

SEARCH · Search NASA

Results for “FLEX”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

Human Performance in Simulated Reduced Gravity Environments

NASA is currently designing a new space suit capable of working in deep space and on Mars. Designing a suit is very difficult and often requires trade‐offs between performance, cost, mass, and system complexity. Our current understanding of human performance in reduced gravity in a planetary environment (the moon or Mars) is limited to lunar observations, studies from the Apollo program, and recent suit tests conducted at JSC using reduced gravity simulators. This study will look at our most recent reduced gravity simulations performed on the new Active Response Gravity Offload System (ARGOS) compared to the C‐9 reduced gravity plane. Methods: Subjects ambulated in reduced gravity analogs to obtain a baseline for human performance. Subjects were tested in lunar gravity (1.6 m/sq s) and Earth gravity (9.8 m/sq s) in shirt‐sleeves. Subjects ambulated over ground at prescribed speeds on the ARGOS, but ambulated at a self‐selected speed on the C‐9 due to time limitations. Subjects on the ARGOS were given over 3 minutes to acclimate to the different conditions before data was collected. Nine healthy subjects were tested in the ARGOS (6 males, 3 females, 79.5 +/- 15.7 kg), while six subjects were tested on the C‐9 (6 males, 78.8 +/- 11.2 kg). Data was collected with an optical motion capture system (Vicon, Oxford, UK) and was analyzed using customized analysis scripts in BodyBuilder (Vicon, Oxford, UK) and MATLAB (MathWorks, Natick, MA, USA). Results: In all offloaded conditions, variation between subjects increased compared to 1‐g. Kinematics in the ARGOS at lunar gravity resembled earth gravity ambulation more closely than the C‐9 ambulation. Toe‐off occurred 10% earlier in both reduced gravity environments compared to earth gravity, shortening the stance phase. Likewise, ankle, knee, and hip angles remained consistently flexed and had reduced peaks compared to earth gravity. Ground reaction forces in lunar gravity (normalized to Earth body weight) were 0.4 +/- 0.2 on the ARGOS, but only 0.2 +/- 0.1 on the C‐9. Discussion: Gait analysis showed differences in joint kinematics and temporal‐spatial parameters between the reduced gravity simulators and with respect to earth gravity. Although most of the subjects chose a somewhat unique ambulation style as a result of learning to ambulate in a new environment, all but two were consistent with keeping an Earth‐like gait. Learning how reduced gravity affects ambulation will help NASA to determine optimal suit designs, influence mission planning, help train crew, and may shed light on the underlying methods the body uses to optimize gait for energetic efficiency. Conclusion: Kinematic and kinetic analysis demonstrated noteworthy differences between an offloaded environment and 1‐g, as would be expected. The analysis showed a trend to change the ambulation style in an offloaded environment to a rolling‐loping walk (resembling crosscountry skiing) with increased swing time. This ambulation modification, particularly in the ARGOS, indicated that the relative kinetic energy of the subject was increased, on average, per the static body weight compared to the 1‐g condition. How much of this was influenced by the active offloading of the ARGOS system is unknown.

Cowley, Matthew↗

Dust Tolerant Commodity Transfer Interface Mechanisms for Planetary Surfaces

Regolith is present on most planetary surfaces such as Earth's moon, Mars, and Asteroids. If human crews and robotic machinery are to operate on these regolith covered surfaces, they must face the consequences of interacting with regolith fines which consist of particles below 100 microns in diameter down to as small as submicron scale particles. Such fine dust will intrude into mechanisms and interfaces causing a variety of problems such as contamination of clean fluid lines, jamming of mechanisms and damaging connector seals and couplings. Since multiple elements must be assembled in space for system level functionality, it will be inevitable that interfaces will be necessary for structural connections, and to pass commodities such as cryogenic liquid propellants, purge and buffer gases, water, breathing air, pressurizing gases, heat exchange fluids, power and data. When fine regolith dust is present in the environment it can be lofted into interfaces where it can compromise the utility of the interface by preventing the connections from being successfully mated, or by inducing fluid leaks or degradation of power and data transmission. A dust tolerant, hand held "quick-disconnect" cryogenic fluids connector housing has been developed at NASA KSC which can be used by astronaut crews to connect flex lines that will transfer propellants and other useful fluids to the end user. In addition, a dust tolerant, automated, cryogenic fluid, multiple connector, power and data interface mechanism prototype has been developed, fabricated and demonstrated by NASA at Kennedy Space Center (KSC). The design and operation of these prototypes are explained and discussed.

Dust Tolerant↗

Deployment Methods for an Origami-Inspired Rigid-Foldable Array

The purpose of this work is to evaluate several deployment methods for an origami-inspired solar array at two size scales: 25-meter array and CubeSat array. The array enables rigid panel deployment and introduces new concepts for actuating CubeSat deployables. The design for the array was inspired by the origami flasher model (Lang, 1997; Shafer, 2001). Figure 1 shows the array prototyped from Garolite and Kapton film at the CubeSat scale. Prior work demonstrated that rigid panels like solar cells could successfully be folded into the final stowed configuration without requiring the panels to flex (Zirbel, Lang, Thomson, & al., 2013). The design of the array is novel and enables efficient use of space. The array can be wrapped around the central bus of the spacecraft in the case of the large array, or can accommodate storage of a small instrument payload in the case of the CubeSat array. The radial symmetry of this array around the spacecraft is ideally suited for spacecraft that need to spin. This work focuses on several actuation methods for a one-time deployment of the array. The array is launched in its stowed configuration and it will be deployed when it is in space. Concepts for both passive and active actuation were considered.

Zirbel, Shannon A.↗

Advanced Launch Technology Life Cycle Analysis Using the Architectural Comparison Tool (ACT)

Life cycle technology impact comparisons for nanolauncher technology concepts were performed using an Affordability Comparison Tool (ACT) prototype. Examined are cost drivers and whether technology investments can dramatically affect the life cycle characteristics. Primary among the selected applications was the prospect of improving nanolauncher systems. As a result, findings and conclusions are documented for ways of creating more productive and affordable nanolauncher systems; e.g., an Express Lane-Flex Lane concept is forwarded, and the beneficial effect of incorporating advanced integrated avionics is explored. Also, a Functional Systems Breakdown Structure (F-SBS) was developed to derive consistent definitions of the flight and ground systems for both system performance and life cycle analysis. Further, a comprehensive catalog of ground segment functions was created.

Space Flight Architecture↗

Fully Integral, Flexible Composite Driveshaft

An all-composite driveshaft incorporating integral flexible diaphragms was developed for prime contractor testing. This new approach makes obsolete the split lines required to attach metallic flex elements and either metallic or composite spacing tubes in current solutions. Subcritical driveshaft weights can be achieved that are half that of incumbent technology for typical rotary wing shaft lengths. Spacing tubes compose an integral part of the initial tooling but remain part of the finished shaft and control natural frequencies and torsional stability. A concurrently engineered manufacturing process and design for performance competes with incumbent solutions at significantly lower weight and with the probability of improved damage tolerance and fatigue life.

Lawrie, Duncan↗

Monitoring Human Performance During Suited Operations: A Technology Feasibility Study Using EMU Gloves

Mobility tracking of human subjects while conducting suited operations still remains focused on the external movement of the suit and little is known about the human movement within it. For this study, accelerometers and bend sensitive resistors were integrated into a custom carrier glove to quantify range of motion and dexterity from within the pressurized glove environment as a first stage feasibility study of sensor hardware, integration, and reporting capabilities. Sensors were also placed on the exterior of the pressurized glove to determine if it was possible to compare a glove joint angle to the anatomical joint angle of the subject during tasks. Quantifying human movement within the suit was feasible, with accelerometers clearly detecting movements in the wrist and reporting expected joint angles at maximum flexion or extension postures with repeatability of plus or minus 5 degrees between trials. Bend sensors placed on the proximal interphalangeal and distal interphalangeal joints performed less well. It was not possible to accurately determine the actual joint angle using these bend sensors, but these sensors could be used to determine when the joint was flexed to its maximum and provide a general range of mobility needed to complete a task. Further work includes additional testing with accelerometers and the possible inclusion of hardware such as magnetometers or gyroscopes to more precisely locate the joint in 3D space. We hope to eventually expand beyond the hand and glove and develop a more comprehensive suit sensor suite to characterize motion across more joints (knee, elbow, shoulder, etc.) and fully monitor the human body operating within the suit environment.

Bekdash, Omar↗

Leak Mitigation in Mechanically Pumped Fluid Loops for Long Duration Space Missions

Mechanically pumped fluid loops (MPFLs) are increasingly considered for spacecraft thermal control. A concern for long duration space missions is the leak of fluid leading to performance degradation or potential loop failure. An understanding of leak rate through analysis, as well as destructive and non-destructive testing, provides a verifiable means to quantify leak rates. The system can be appropriately designed to maintain safe operating pressures and temperatures throughout the mission. Two MPFLs on the Mars Science Laboratory Spacecraft, launched November 26, 2011, maintain the temperature of sensitive electronics and science instruments within a -40 deg C to 50 deg C range during launch, cruise, and Mars surface operations. With over 100 meters of complex tubing, fittings, joints, flex lines, and pumps, the system must maintain a minimum pressure through all phases of the mission to provide appropriate performance. This paper describes the process of design, qualification, test, verification, and validation of the components and assemblies employed to minimize risks associated with excessive fluid leaks from pumped fluid loop systems.

thermal controls↗

Accommodating Thickness in Origami-Based Deployable Arrays

The purpose of this work is to create deployment systems with a large ratio of stowed-to-deployed diameter. Deployment from a compact form to a final flat state can be achieved through origami-inspired folding of panels. There are many models capable of this motion when folded in a material with negligible thickness; however, when the application requires the folding of thick, rigid panels, attention must be paid to the effect of material thickness not only on the final folded state, but also during the folding motion (i.e., the panels must not be required to flex to attain the final folded form). The objective is to develop new methods for deployment from a compact folded form to a large circular array (or other final form). This paper describes a mathematical model for modifying the pattern to accommodate material thickness in the context of the design, modeling, and testing of a deployable system inspired by an origami six-sided flasher model. The model is demonstrated in hardware as a 1/20th scale prototype of a deployable solar array for space applications. The resulting prototype has a ratio of stowed-to-deployed diameter of 9.2 (or 1.25 m deployed outer diameter to 0.136 m stowed outer diameter).

flasher↗

Validation of a Cephalad Fluid Shift Countermeasure

INTRODUCTION: This project will provide critical data required to objectively determine how an optimized thigh cuff could be incorporated into the NASA integrated physiological countermeasure suite. This project will determine if thigh cuffs used during simulated spaceflight impact intracranial pressure (ICP), ocular structure and function, and intraocular pressure (IOP) using state of-the-art techniques. Additionally, some of the same methods, hardware, and protocols will be employed in the present investigation to enable direct comparisons to the International Space Station (ISS) "Fluid Shifts" experiment with Chibis-Lower Body Negative Pressure (LBNP). This study will determine the temporal physiological responses of thigh cuff application and removal on ocular and cerebral variables (including invasive ICP) in a microgravity analog. Furthermore, this proposed study will determine tissue pressure distribution applied by thigh cuffs in order to improve comfort, mobility, and efficacy of the countermeasure. Our specific aim is to determine the efficacy of a novel thigh cuff device to mitigate cephalad fluid shifts. We hypothesize that a thigh cuff countermeasure employed in a microgravity analog will temporarily reverse or attenuate ocular and cerebral-volume-pressure variables, approaching normal Earth-based seated posture, the most frequent posture assumed in daily life. In addition, we hypothesize that the magnitude of fluid and pressure redistribution using a thigh cuff countermeasure may require a longer exposure time than that of Chibis-LBNP (using ground-based data from our "Fluid Shifts" project). This project directly addresses Critical Path Roadmap Risks and Questions regarding "Risk of Spaceflight-Induced Intracranial Hypertension/Vision Alterations," and IRP Gap VIIP13: We need to identify preventative and treatment countermeasures to mitigate changes in ocular structure and function and intracranial pressure during spaceflight. METHODS: Noninvasive measures and tissue pressure distributions beneath thigh cuffs The objectives of this study are to: 1) determine the distribution of skin surface pressures beneath the advanced thigh cuff in ten subjects, 2) calibrate the built-in pressure measurement system of the advanced thigh cuff using an industry standard device, and 3) collect subjective feedback and data on the new cuff design to allow for further adjustments prior to invasive studies. A Tekscan Industrial Sensing (I-Scan) system will measure the pressure distribution of the advanced thigh cuff against the skin. In addition, we will measure blood pooling in the thigh and record the circumference of the thigh using Hokanson strain gauge plethysmography. The advanced thigh cuff will be adjusted to obtain a skin contact pressure of 30-50 mmHg as visualized on the Tekscan system. The built-in advanced thigh cuff pressure monitor will be recorded simultaneously to allow direct comparison to the Tekscan measurements. The volunteer will then remove the thigh cuff and remain at rest for five minutes with no legging applied. The thigh cuff will be donned again and pressure measurements will be taken in the same manner for up to 10 repetitions to show reproducibility of pressure after donning. At the conclusion of the study, subjects will be asked to flex their knee, stand, walk, and sit with the thigh cuff activated. During each of these maneuvers the subject will rate their pain/comfort using a modified Borg scale. Effect of thigh cuffs on ICP during simulated microgravity Ommaya reservoir patients will be recruited from the John Wayne Cancer Institute. Ommaya reservoirs provide safe and direct access for the measurement of ICP. Subjects will be instrumented for continuous blood pressure, ECG, and invasive ICP measures. The subjects will be positioned in the upright sitting posture for a 10-minute stabilization period. After the 10-minute stabilization period, imaging measures [ICP, Optical Coherence Tomography, IOP, ocular and vascular ultrasound] will be performed. Following baseline seated measures, the subject will be positioned randomly in the supine, 15deg head-down-tilt, and 15deg head-down-tilt with thigh cuffs and measures repeated. DISCUSSION: Tests to down-select thigh cuff designs will occur in early 2016. Invasive ICP and noninvasive eye imaging tests will begin in spring 2016. Supported by NSBRI through NCC 9-58.

Macias, B.↗

CryoCart Restoration and Vacuum Pipe Construction

Propulsion systems that utilize hypergolic propellants have been used to power space vehicles since the beginning of the space program. Liquid methane and oxygen propulsion systems have emerged as an alternative and have proven to be more environmentally friendly. The incorporation of liquid methane/liquid oxygen (LOX) into the propulsion system has demonstrated an increase in engine performance, as well as a reduction in the volume, size and complexity of the system. Consequently, reducing the total mass of the vehicle which is a crucial aspect that is considered when planning space missions to both the Moon and Mars [1]. Project Morpheus has made significant advancements in liquid oxygen/liquid methane propulsion system technologies by incorporating a LOX/methane propulsion system to a vertical test bed. The vehicle consisted of a 5,000 lb main engine and four 20 lb remote control system (RCS) engines that utilize liquid methane/LOX as its propellant [1]. The vehicle completed successful flight testing at Kennedy Space Center in 2014 which marked the completion of the Morpheus project. Subsequent projects utilizing Morpheus' vertical test bed have been developed to make further advancements. One of the subsequent projects consisted of the addition of a smaller 2,000 lb main engine and a cold helium heat exchanger which would make it possible for a pressurant tank systems to be send to Mars or the Moon by significantly decreasing the overall mass and volume of the pressurant tank. The hot fire tests of the integrated system with the smaller main engine and cold helium heat exchanger were successful at sea level, but further studies are being conducted to better understand how the vertical test bed will behave under thermal-vacuum conditions. For this reason, the integrated vehicle will be taken to Plum Brook to be tested in a chamber capable of simulating these conditions. To ensure that the vehicle will function properly under vacuum conditions, testing will be first completed at the component level. During this process, the igniter of the main engine and the RCS thrusters will be tested under a vacuum. To complete the testing of the components, the test setup first needed to be finalized. The CryoCart is being used to feed the propellants to the test article. The CryoCart is a movable test set-up that was developed in 2009 to provide a mobile platform for testing oxygen/methane systems with hot-fire capability up to 100 lbf. The CryoCart consists of three different systems: Oxygen, Methane, and liquid Nitrogen. The Oxygen and Methane systems are placed into two different carts while the liquid nitrogen system is mainly located in the methane cart. Over the years, the CryoCart has been utilized for different projects and has undergone deterioration. For this reason, a new phase has been developed to rebuild it to working conditions once again. During my internship, I was aiding in the construction and restoration of the CryoCart. In the initial stages of the process, I updated the fluid and electrical schematics for the oxygen, methane, and test article systems. The original CryoCart consisted of an electrical panel that utilized electromechanical relays and a terminal to drive the igniter power and signal, as well as the main fuel and oxygen valves. This electrical panel connected to the CryoCart through various wire harnesses that could be found exiting from the CryoCart. First, it was determined how these harnesses connected to the electromechanical relays so that they worked correctly. Once the electrical system was understood, an alternative for the electromechanical relays and the Molex connectors used throughout the system was sought since these components can often prove to be unreliable. Solid State relays and MIL connectors were purchased to serve as replacements. Upon arrival of the parts, crimping and wiring was completed to install the new solid state relays and MIL connectors. During the replacement of the relays and connectors, system checks of the electrical system were ran to ensure that the system was working correctly. While completing system checks, the pressure transducers that were not functioning properly were also replaced and any issue with the wiring or signal was addressed. Once the electrical components were replaced, the restoration of the fluid system began. Parts of the tubing in the CryoCart had to be rebuild and often consisted of sizing, cutting, bending, filing, and sanding the tubing to prepare it to be flared. Many components had to be proof-tested to bring their certifications up to date, and several components had to be replaced. Various flex hoses, valves, and fittings were send to the Clean Lab because they were new, dirty, or had gone through proof-testing. Once they arrived from the cleaning lab they had to be put back to the system and leak checks and functional tests were conducted. In the Nitrogen system, the copper tubing located in the Oxygen cart was rebuild and Aerogel insulation was added to this section. A new gaseous nitrogen system was added to the CryoCart to purge the vacuum tube which will serve as the test chamber. Once the CryoCart was completed, construction of parts of the vacuum tube began. A flange was manufactured with welded fittings to hold the line of the vacuum pump as well as some extra fittings which will serve as extra inlets used to introduce fluid lines to the vacuum tube. Stress analysis was ran in this flange to ensure that it would not fail under vacuum conditions. The fluid lines leading from the air side of the vacuum to the test article were also constructed and added to the mount that had already been manufactured. Three different sets of tubing were constructed to accommodate the seven different RCS thruster and the main engine igniter that are going to be tested. Full electrical system checks were completed to ensure that all the wire harnesses and valves were functioning. Upon the completion of the CryoCart and the vacuum tube, hot fire testing for the RCS thrusters and the main engine igniter are going to begin. During this time any issues encountered with the engines or igniter will be addressed to ensure that the components function under vacuum conditions. After successful completion of testing, the vertical test bed, Morpheus, will be rebuilt and prepared to be sent to Plum Brook. In Plum Brook, the vehicle will be tested in the thermal-vacuum chamber to demonstrate that integrated lox-methane propulsion system operation in space-like conditions. This internship has allowed me the opportunity to gain valuable hands on experience and to develop skills that will aid in my education as well as in the workforce, while at the same time helping me determine that I would like to further pursue a career in propulsion engineering.

Chaidez, Mariana↗

Comparison of Sun-Induced Chlorophyll Fluorescence Estimates Obtained from Four Portable Field Spectroradiometers

Remote Sensing of Sun-Induced Chlorophyll Fluorescence (SIF) is a research field of growing interest because it offers the potential to quantify actual photosynthesis and to monitor plant status. New satellite missions from the European Space Agency, such as the Earth Explorer 8 FLuorescence EXplorer (FLEX) mission-scheduled to launch in 2022 and aiming at SIF mapping-and from the National Aeronautics and Space Administration (NASA) such as the Orbiting Carbon Observatory-2 (OCO-2) sampling mission launched in July 2014, provide the capability to estimate SIF from space. The detection of the SIF signal from airborne and satellite platform is difficult and reliable ground level data are needed for calibration/validation. Several commercially available spectroradiometers are currently used to retrieve SIF in the field. This study presents a comparison exercise for evaluating the capability of four spectroradiometers to retrieve SIF. The results show that an accurate far-red SIF estimation can be achieved using spectroradiometers with an ultrafine resolution (less than 1 nm), while the red SIF estimation requires even higher spectral resolution (less than 0.5 nm). Moreover, it is shown that the Signal to Noise Ratio (SNR) plays a significant role in the precision of the far-red SIF measurements.

Julitta, Tommaso↗

All-Elastomer 3-Axis Contact Resistive Tactile Sensor Arrays and Micromilled Manufacturing Methods Thereof

At least one tactile sensor includes an insulating layer and a conductive layer formed on the surface of the insulating layer. The conductive layer defines at least one group of flexible projections extending orthogonally from the surface of the insulating layer. The flexible projections include a major projection extending a distance orthogonally from the surface and at least one minor projection that is adjacent to and separate from the major projection wherein the major projection extends a distance orthogonally that is greater than the distance that the minor projection extends orthogonally. Upon a compressive force normal to, or a shear force parallel to, the surface, the major projection and the minor projection flex such that an electrical contact resistance is formed between the major projection and the minor projection. A capacitive tactile sensor is also disclosed that responds to the normal and shear forces.

Charalambides, Alexandros↗

Cracking Problems and Mechanical Characteristics of PME and BME Ceramic Capacitors

Most failures in MLCCs are caused by cracking that create shorts between opposite electrodes of the parts. A use of manual soldering makes this problem especially serious for space industry. Experience shows that different lots of ceramic capacitors might have different susceptibility to cracking under manual soldering conditions. This simulates a search of techniques that would allow revealing capacitors that are most robust to soldering-induced stresses. Currently, base metal electrode (BME) capacitors are introduced to high-reliability applications as a replacement of precious metal electrode (PME) parts. Understanding the difference in the susceptibility to cracking between PME and BME capacitors would facilitate this process. This presentation gives a review of mechanical characteristics measured in-situ on MLCCs that includes flexural strength, Vickers hardness, indentation fracture toughness, and the board flex testing and compare characteristics of BME and PME capacitors. A history case related to cracking in PME capacitors that caused flight system malfunctions and mechanisms of failure are considered. Possible qualification tests that would allow evaluation of the resistance of MLCCs to manual soldering are suggested and perspectives related to introduction of BME capacitors discussed.

Reliability↗

On-Ground Calibration and Optical Alignment for the Orion Optical Navigation Camera

The Orion Multi-Purpose Crew Vehicle on-board Navigation System will utilize the Optical Navigation measurements of the Moon and Earth during cis-lunar operations. Misalignment or an un-calibrated optical navigation camera may cause large measurement residuals in any on-board attitude determination and navigation system. Therefore, a novel estimation technique to calibrate the internal camera parameters, and a high accuracy optical alignment procedure to estimate the external camera alignment are introduced in this paper. The intrinsic camera parameters such as the focal length, the principle point offsets, and the camera lens distortion parameters will be estimated and evaluated using images of star fields. This calibration estimation technique can be used either on-ground or in flight. The proposed technique in this paper is using the discrepancy between imaged star vectors attained from the OpNav camera, and the matched star vectors from the star catalog to determine the changes in internal camera parameters. This gave rise to the two basic types of calibration the attitude dependent and attitude independent methods. The former utilizes the errors in imaged and cataloged vectors themselves, and the latter using the discrepancy in angles between pairs of vectors from the camera and catalog. The alignment procedure is carried out using Theodolite autocollimator measurements taken off alignment cubes mounted on the Orion frame and also the measurements from the OpNav focal plane. It is assumed that the alignment cubes and OpNav camera are rigidly mounted to the frame so that flexing effects do not significantly alter the orientation of the cubes relative to the OpNav camera.

Samaan, Malak↗

Development of a Novel Helmet Support Assembly for NASA Orion Crew Survival Suit

Orion Spacecraft water landing environments have necessitated the design and testing of a novel Helmet Support Assembly (HSA) as part of the NASA Orion Crew Survival Systems (OCSS) launch and re-entry spacesuit. A series of development sled tests using 5 th female, 50th male, and 95th male Hybrid III Anthropometric Test Devices (ATDs) simulated worst case water landings and identified the need for an integrated suit countermeasure to control the helmet during dynamic loading. Initial prototype countermeasures rigidly restrained the helmet keeping the helmet in place as desired, but led to large force and moment transmission to the upper neck. Further development led to a flexible HSA which used high-strength steel wire contoured to the size-matched ATD thorax and attached to both the front and rear of the neck ring. The selected wire diameter and contoured shape provided some ability to flex under the expected worst-case dynamic loads. The existing shoulder harness was used to restrain the helmet motion during “eyeballs out/down” loading while also attempting to prevent head-to-helmet contact in “eyeballs down” spinal-axis loading. A new small prototype helmet was also developed and tested for the 5th and 50th ATDs with both HSA devices. Dynamic impact tests were conducted on the HIA (Horizontal Impulse Accelerator) at Wright Patterson Air Force Base (WPAFB) under simulated off-nominal landing conditions using a representative Orion seat and 5-point harness. For each ATD size, peak Neck Injury Criteria (Nij) were compared to equivalent sled tests with an unsuited ATD configuration. Adding a helmet without attempting to control motion increased peak Nij values for all ATD sizes. The use of the rigid countermeasure showed decreased peak Nij results for the 5th female, but increased peak Nij values for both 50th configurations and the 95th male ATDs. By comparison, the flexible HSA showed reduced peak Nij values for all ATD sizes. Overall, this series of dynamic impact tests identified a risk of increased crew neck loading when under- or over-restraining the helmet during simulated Orion water landings and also demonstrated an effective strategy to mitigate those loads with a compliant HSA design.

Safety↗

Cryogenic Angle Measurement at NASA Langley

NASA’s National Transonic Facility is one of the few cryogenic wind-tunnel facilities in the world, where tunnel conditions may reach -250 F. Model angle of attack (AoA) at NTF is typically measured by an on-board accelerometer package that is exposed to the cryogenic tunnel conditions. These NTF AoA packages house two Q-Flex accelerometers in a compact heated environment in order to maintain constant temperature of the sensors for stability. Recently, drift in sensor output was observed in one of the NTF AoA packages. The drift is correlated with the AoA package temperature and cryogenic soak time. This paper studies the temperature and time dependent behavior of the NTF AoA packages, and reviews their design and calibration. Recommended improvements to the AoA packages are made to improve the stability of the model angle of attack measurements at cryogenic conditions.

Toro, Kenneth G.↗

TPSAS-NF1676L-14834-DND

A recent spin-off from flight deck adaptive automation research at NASA Langley Research Center is a biocybernetic invention referred to informally as MindShift. When using the MindShift technology, a person is able to play off-the-shelf Nintendo Wii games enhanced with biofeedback, which is used to improve self-regulation of physiological functioning. Therefore, the user experiences the challenge of regulating their physiological responses during gameplay in addition to the intended challenges presented in the video game. The research projects being conducted under the supervision of Dr. Alan Pope and Chad Stephens at NASA Langley Research Center examine the effects of interacting with the MindShift invention technology on subjects' self-regulation of heart rate and brainwave activity, performance in the games, performance on cognitive tasks, and subjective experience of effort (i.e., workload). The MindShift invention's effects are being compared to the effects of interacting with the games without the MindShift technology and to the effects of interacting with commercial-off-the-shelf (COTS) brain-computer interface (BCI) technology, specifically the Mattel Mind Flex and the Uncle Milton Star Wars Force Trainer. A 32-channel electroencephalograph system is used to record subjects' brainwave and electrocardiographic activity. The potential for biofeedback game system applications is wide-ranging - from a more engaging form of clinical biofeedback training to a new challenge for avid gamers. Consequently, research needs to be conducted to fully understand the effects that these new games have on a person's physiological and psychological functioning. Biocybernetic technology like MindShift developed from the idea that operators of critical systems such as aerospace systems could hone their stress management and attention skills in biofeedback-augmented leisure activities while off-the-job in order to positively affect their on-the-job performance. This human performance enhancement technology is applicable to skill training on manually controlled critical tasks, such as unmanned aerial vehicle teleoperation, thus enabling the training of cognitive skills to be concurrent with manual skills. Furthermore, this type of technology can apply to medical and clinical uses of biofeedback by serving as an additional form of clinical biofeedback training that may be particularly useful for those with ADHD.

Brittany N Neilson↗