Search NASA⌕ Search

SEARCH · Search NASA

Results for “FLUID MEASUREMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

Constitutive modelling of lubricants in concentrated contacts at high slide to roll ratios

A constitutive lubricant friction model for rolling/sliding concentrated contacts such as gears and cams was developed, based upon the Johnson and Tevaarwerk fluid rheology model developed earlier. The friction model reported herein differs from the earlier rheological models in that very large slide to roll ratios can now be accommodated by modifying the thermal response of the model. Also the elastic response of the fluid has been omitted from the model, thereby making it much simpler for use in the high slide to roll contacts. The effects of this simplification are very minimal on the outcome of the predicted friction losses (less than 1%). In essence then the lubricant friction model developed for the high slide to roll ratios treats the fluid in the concentrated contact as consisting of a nonlinear viscous element that is pressure, temperature, and strain rate dependent in its shear response. The fluid rheological constants required for the prediction of the friction losses at different contact conditions are obtained by traction measurements on several of the currently used gear lubricants. An example calculation, using this model and the fluid parameters obtained from the experiments, shows that it correctly predicts trends and magnitude of gear mesh losses measured elsewhere for the same fluids tested here.

Tevaarwerk, J. L.↗

Comparison of Interstitial Fluid pH, PCO2, PO2 with Venous Blood Values During Repetitive Handgrip Exercise

We evaluated the use of a small, fiber optic sensor to measure pH, PCO2 and PO2 from forearm muscle interstitial fluid (IF) during handgrip dynamometry. PURPOSE: Compare pH, PCO2 and PO2 values obtained from venous blood with those from the IF of the flexor digitorum superficialis (FDS) during three levels of exercise intensity. METHODS: Six subjects (5M/1F), average age 29+/-5 yrs, participated in the study. A venous catheter was placed in the retrograde direction in the antecubital space and a fiber optic sensor (Paratrend, Diametrics Medical, Inc.) was placed through a 22 G catheter into the FDS muscle under ultrasound guidance. After a 45 min rest period, subjects performed three 5-min bouts of repetitive handgrip exercise (2s contraction/1 s relaxation) at attempted levels of 15%, 30% and 45% of maximal voluntary contraction. The order of the exercise bouts was random with the second and third bouts started after blood lactate had returned to baseline. Venous blood was sampled every minute during exercise and analyzed with an I-Stat CG-4+ cartridge, while IF fiber optic sensor measurements were obtained every 2 s. Change from pre-exercise baseline to end of exercise was computed for pH, PCO2 and PO2. Blood and IF values were compared with a paired t-test. RESULTS: Baseline values for pH, PCO2 and PO2 were 7.37+/-0.02, 46+/-4 mm Hg, and 36+/-6 mm Hg respectively in blood and 7.39+/-0.02, 44+/-6 mm Hg, and 35+/-14 mm Hg in IF. Average changes over all exercise levels are noted in the Table below. For each parameter the exercise-induced change was at least twice as great in IF as in blood. In blood and IF, pH and PCO2 increases were directly related to exercise intensity. Change in venous PO2 was unrelated to exercise intensity, while IF PO2 decreased with increases in exercise intensity. CONCLUSIONS: Measurement of IF pH, PCO2 and PO2 is more sensitive to exercise intensity than measurement of the same parameters in venous blood and provides continuous assessment during and after exercise.

Hagan, Ronald Donald↗

Two-Phase Flow in Packed Beds, Filters and Orifices: Summary of Findings of the Packed Bed Reactor Experiment Onboard of the International Space Station

Understanding the hydrodynamics of adiabatic two-phase flows in packed bed reactors enables the optimization of chemical reaction rates and products that crucial in pharmaceuticals and energy production industries. Additionally, this understanding aids in designing more efficient and compact reactors and reducing space and resource requirements. Insights gained from studying and understanding such flows in microgravity contribute to advancements of space technologies and the enhancement of our capabilities for undertaking future long duration safe, and sustainable space exploration missions. The objective of the Packed Bed Reactor Experiment series (PBRE and PBRE-2) was to develop a fundamental understanding of the hydrodynamics of adiabatic two-phase flows through porous media in microgravity. This work provides a description of the PBRE fluid system and presents the highlights of the PBRE and PBRE-2 previously flown with different packings and operated onboard of the International Space Station Microgravity Science Glovebox (ISS-MSG). These highlights include flow patterns and two-phase pressure drop, and the impact of capillary effects on pressure drop at various gas and liquid flow rates. This work also presents preliminary results from the Packed Bed Reactor Experiment-Water Recovery Series (PBRE-WRS) recently flown with filters and orifices, which was also operated on the ISS-MSG. The objective of the experiment is to validate hydrodynamic models at a range of gas and liquid flow rates pertinent to the operation of these test articles. The microgravity environment allows for measurement and observation of aspects of fluid dynamics that are unique when compared to observations made in full or partial gravity environments.

ISS↗

A Two-Axis Direct Fluid Shear Stress Sensor

This innovation is a miniature or micro sized semiconductor sensor design that provides two axis direct non-intrusive measurement of skin friction or wall shear stress in fluid flow. The sensor is fabricated by micro-electro-mechanical system (MEMS) technology, enabling small size and low cost reproductions. The sensors have been fabricated by utilizing MEMS fabrication processes to bond a sensing element wafer to a fluid coupling wafer. This layering technique provides for an out of plane dimension that is on the same order of length as the inplane dimensions. The sensor design has the following characteristics: a shear force collecting plate with dimensions that can be tailored to various application specific requirements such as spatial resolution, temporal resolution and shear force range and resolution. This plate is located coplanar to both the sensor body and flow boundary, and is connected to a dual axis gimbal structure by a connecting column or lever arm. The dual axis gimbal structure has torsional hinges with embedded piezoresistive torsional strain gauges which provide a voltage output that is correlated to the applied shear stress (and excitation current) on force collection plate that is located on the flow boundary surface (hence the transduction method). This combination of design elements create a force concentration and resolution structure that enables the generation of a large stress on the strain gauge from the small shear stress on the flow boundary wall. This design as well as the use of back side electrical contacts establishes a non-intrusive method to quantitatively measure the shear force vector on aerodynamic bodies.

Adcock, Edward E.↗

Ultrasonic Apparatus and Technique to Measure Changes in Intracranial Pressure

Changes in intracranial pressure can be measured dynamically and non-invasively by monitoring one or more cerebrospinal fluid pulsatile components. Pulsatile components such as systolic and diastolic blood pressures are partially transferred to the cerebrospinal fluid by way of blood vessels contained in the surrounding brain tissue and membrane. As intracranial pressure varies these cerebrospinal fluid pulsatile components also vary. Thus, intracranial pressure can be dynamically measured. Furthermore, use of acoustics allows the measurement to be completely non-invasive. In the preferred embodiment, phase comparison of a reflected acoustic signal to a reference signal using a constant frequency pulsed phase-locked-loop ultrasonic device allows the pulsatile components to be monitored. Calibrating the device by inducing a known change in intracranial pressure allows conversion to changes in intracranial pressure.

William T Yost↗

Numerical solutions and laser-Doppler measurements of spin-up

The spin-up flow in a cylinder of homogeneous fluid has been examined both experimentally and numerically. A series of laser-Doppler measurements was made of the zonal flow over a range of Ekman numbers and Rossby numbers at various locations in the interior of the flow. These measurements exceed previous ones in accuracy. The weak inertial modes excited by the impulsive start are detectable. The numerical simulations used the primitive equations in axisymmetric form and employed finite-difference techniques on both constant and variable grids. The number of grid points necessary to resolve the Ekman layers was determined. A thorough comparison of the simulations and the experimental measurements is made which includes the details of the amplitude and frequency of the inertial modes. Agreement to within the experimental tolerance is achieved. Analytical results for conditions identical to those in the experiments are not available but some similar linear and nonlinear theories are also compared with the experiments.

Warn-Varnas, A.↗

An experimental technique for performing 3-D LDA measurements inside whirling annular seals

During the last several years, the Fluid Mechanics Division of the Turbomachinery Laboratory at Texas A&M University has developed a rather unique facility with the experimental capability for measuring the flow field inside journal bearings, labyrinth seals, and annular seals. The facility consists of a specially designed 3-D LDA system which is capable of measuring the instantaneous velocity vector within 0.2 mm of a wall while the laser beams are aligned almost perpendicular to the wall. This capability was required to measure the flow field inside journal bearings, labyrinth seals, and annular seals. A detailed description of this facility along with some representative results obtained for a whirling annular seal are presented.

Morrison, Gerald L.↗

Cryogenic Fluid In-Situ Liquefaction for Landers: Prototype Demonstration

As the advancement of In-Situ Resource Utilization concepts and systems continue to develop, applicable technology development and maturation continues in parallel. While there are many different ways to use the resources found on other bodies, one of the most prevalent suggested applications is the manufacturing of propellants. One of the key technologies for the eventual use of these propellant production based ISRU systems is the liquefaction and storage of the produced propellants. The most mentioned propellant combinations include oxygen-hydrogen and oxygen-methane. The liquefaction of oxygen in these systems will be different than that on Earth, which mainly revolves around the distillation of air. These systems have been developed conceptually and many of the components have been previously tested or are in development. However, the need to demonstrate the system level operations still exists. The demonstration of a prototypical oxygen liquefaction system using tube-on-tank broad area cooling was completed to better understanding system level operations during liquefaction activities. Demonstration testing included system performance determination, constant liquefaction demonstrations, and transient liquefaction demonstrations. The demonstrations showed the operational capabilities of the tube-on-tank system with an integrated cryocooler. Additional testing explored subsurface vs ullage introduction of the gaseous oxygen flow stream as well as demonstrating a novel fiber optic sensor that measured the temperature gradients along the fluid center line within the tank.

ISRU↗

Cryogenic Fluid In-Situ Liquefaction for Landers: Prototype Demonstration

As the advancement of In-Situ Resource Utilization concepts and systems continue to develop, applicable technology development and maturation continues in parallel. While there are many different ways to use the resources found on other bodies, one of the most prevalent suggested applications is the manufacturing of propellants. One of the key technologies for the eventual use of these propellant production based ISRU systems is the liquefaction and storage of the produced propellants. The most mentioned propellant combinations include oxygen-hydrogen and oxygen-methane. The liquefaction of oxygen in these systems will be different than oxygen liquefaction systems on Earth, which mainly revolves around the distillation of air. These systems have been developed conceptually and many of the components have been previously tested or are in development. However, the need to demonstrate the system level operations still exists. The demonstration of a prototypical oxygen liquefaction system using tube-on-tank broad area cooling was completed to better understanding system level operations during liquefaction activities. Demonstration testing included system performance determination, constant liquefaction demonstrations, and transient liquefaction demonstrations. The demonstrations showed the operational capabilities of the tube-on-tank system with an integrated cryocooler. Additional testing explored subsurface vs ullage introduction of the gaseous oxygen flow stream as well as demonstrating a novel fiber optic sensor that measured the temperature gradients along the fluid center line within the tank.

ISRU↗

Cryogenic Fluid In-Situ Liquefaction for Landers: Prototype Demonstration

As the advancement of In-Situ Resource Utilization concepts and systems continue to develop, applicable technology development and maturation continues in parallel. While there are many different ways to use the resources found on other bodies, one of the most prevalent suggested applications is the manufacturing of propellants. One of the key technologies for the eventual use of these propellant production based ISRU systems is the liquefaction and storage of the produced propellants. The most mentioned propellant combinations include oxygen-hydrogen and oxygen-methane. The liquefaction of oxygen in these systems will be different than oxygen liquefaction systems on Earth, which mainly revolves around the distillation of air. These systems have been developed conceptually and many of the components have been previously tested or are in development. However, the need to demonstrate the system level operations still exists. The demonstration of a prototypical oxygen liquefaction system using tube-on-tank broad area cooling was completed to better understanding system level operations during liquefaction activities. Demonstration testing included system performance determination, constant liquefaction demonstrations, and transient liquefaction demonstrations. The demonstrations showed the operational capabilities of the tube-on-tank system with an integrated cryocooler. Additional testing explored subsurface vs ullage introduction of the gaseous oxygen flow stream as well as demonstrating a novel fiber optic sensor that measured the temperature gradients along the fluid center line within the tank.

ISRU↗

Simulations & Measurements of Airframe Noise: A BANC Workshops Perspective

Airframe noise corresponds to the acoustic radiation due to turbulent flow in the vicinity of airframe components such as high-lift devices and landing gears. Since 2010, the American Institute of Aeronautics and Astronautics has organized an ongoing series of workshops devoted to Benchmark Problems for Airframe Noise Computations (BANC). The BANC workshops are aimed at enabling a systematic progress in the understanding and high-fidelity predictions of airframe noise via collaborative investigations that integrate computational fluid dynamics, computational aeroacoustics, and in depth measurements targeting a selected set of canonical yet realistic configurations that advance the current state-of-the-art in multiple respects. Unique features of the BANC Workshops include: intrinsically multi-disciplinary focus involving both fluid dynamics and aeroacoustics, holistic rather than predictive emphasis, concurrent, long term evolution of experiments and simulations with a powerful interplay between the two, and strongly integrative nature by virtue of multi-team, multi-facility, multiple-entry measurements. This paper illustrates these features in the context of the BANC problem categories and outlines some of the challenges involved and how they were addressed. A brief summary of the BANC effort, including its technical objectives, strategy, and selective outcomes thus far is also included.

Choudhari, Meelan↗

The middeck 0-gravity dynamics experiment

The Middeck 0-Gravity Dynamics Experiment (MODE), flown onboard the Shuttle STS-48 Mission, consists of three major elements: the Experiment Support Module, a dynamics test bed providing computer experiment control, analog signal conditioning, power conditioning, an operator interface consisting of a keypad and display, experiment electrical and thermal control, and archival data storage: the Fluid Test Article assembly, used to investigate the dynamics of fluid-structure interaction in 0-gravity; and the Structural Test Article for investigating the open-loop dynamics of structures in 0-gravity. Deployable, erectable, and rotary modules were assembled to form three one- and two-dimensional structures, in which variations in bracing wire and rotary joint preload could be introduced. Change in linear modal parameters as well as the change in nonlinear nature of the response is examined. Trends in modal parameters are presented as a function of force amplitude, joint preload, and ambient gravity. An experimental study of the lateral slosh behavior of contained fluids is also presented. A comparison of the measured earth and space results identifies and highlights the effects of gravity on the linear and nonlinear slosh behavior of these fluids.

Crawley, Edward F.↗

NASA Tech Briefs, February 2008

Topics discussed include: Optical Measurement of Mass Flow of a Two-Phase Fluid; Selectable-Tip Corrosion-Testing Electrochemical Cell; Piezoelectric Bolt Breakers and Bolt Fatigue Testers; Improved Measurement of B(sub 22) of Macromolecules in a Flow Cell; Measurements by a Vector Network Analyzer at 325 to 508 GHz; Using Light to Treat Mucositis and Help Wounds Heal; Increasing Discharge Capacities of Li-(CF)(sub n) Cells; Dot-in-Well Quantum-Dot Infrared Photodetectors; Integrated Microbatteries for Implantable Medical Devices; Oxidation Behavior of Carbon Fiber-Reinforced Composites; GIDEP Batching Tool; Generic Spacecraft Model for Real-Time Simulation; Parallel-Processing Software for Creating Mosaic Images; Software for Verifying Image-Correlation Tie Points; Flexcam Image Capture Viewing and Spot Tracking; Low-Pt-Content Anode Catalyst for Direct Methanol Fuel Cells; Graphite/Cyanate Ester Face Sheets for Adaptive Optics; Atomized BaF2-CaF7 for Better-Flowing Plasma-Spray Feedstock; Nanophase Nickel-Zirconium Alloys for Fuel Cells; Vacuum Packaging of MEMS With Multiple Internal Seal Rings; Compact Two-Dimensional Spectrometer Optics; and Fault-Tolerant Coding for State Machines.

Source record↗

Magnetic Field Effects on Convection and Solidification in Normal and Microgravity

It has been well understood that convective flows induced by g-jitter forces associated with spacecraft are responsible for defects formation and irregularity in product quality during melt growth of single crystals in microgravity. This research is concerned about numerical simulations and experimental measurements for the purpose of developing a fundamental understanding of the g-jitter induced fluid flows and their effects on solidification in microgravity with and without the presence of additional damping forces that are derived from the applied DC magnetic fields. The numerical models include both 2-D and 3-D transient fluid flow, heat transfer, mass transfer and solidification under the combined action of g-jitter and magnetic fields. Numerical simulations using both the 2-D and 3-D models are conducted for both idealized, synthesized and real g-jitter forces, and 2-D simulations are tested against the experimental measurements taken on the thermal oscillator. 2-D solidification models have also been developed and simulations are conducted. Results show that the numerical model predictions compare well with the measurements. Analysis of these results illustrates that an applied magnetic field can have a drastic influence on the convective flows induced by g-jitter and can be particularly useful to suppress the effects resulting from the spiking of g-jitter signatures, which are considered the most detrimental effects on quality of crystals grown in space. Work in progress includes developing 3-D numerical models for solidification phenomena with the presence of both g-jitter and magnetic fields and measurements of flow fluid and its effect on solidification in both transparent fluid and low melting point melts to verify numerical predictions.

Li, Ben Q.↗

Choked flow of fluid nitrogen with emphasis on the thermodynamic critical region

Experimental measurements of critical flow rate and pressure ratio for nitrogen flowing through a nozzle are presented. Data for selected stagnation isotherms from 87.5 to 234 K with pressures to 9.3 MN/m2 are compared to an equilibrium model with real fluid properties and also a nonequilibrium model. Critical flow pressure ratio along an isotherm tends to peak while the flow rate indicates an inflection. The point is closely associated with the transposed critical temperature and represents a change in the fluid structure.

Hendricks, R. C.↗

Balanced Flow Metering and Conditioning: Technology for Fluid Systems

Revolutionary new technology that creates balanced conditions across the face of a multi-hole orifice plate has been developed, patented and exclusively licensed for commercialization. This balanced flow technology simultaneously measures mass flow rate, volumetric flow rate, and fluid density with little or no straight pipe run requirements. Initially, the balanced plate was a drop in replacement for a traditional orifice plate, but testing revealed substantially better performance as compared to the orifice plate such as, 10 times better accuracy, 2 times faster (shorter distance) pressure recovery, 15 times less acoustic noise energy generation, and 2.5 times less permanent pressure loss. During 2004 testing at MSFC, testing revealed several configurations of the balanced flow meter that match the accuracy of Venturi meters while having only slightly more permanent pressure loss. However, the balanced meter only requires a 0.25 inch plate and has no upstream or downstream straight pipe requirements. As a fluid conditioning device, the fluid usually reaches fully developed flow within 1 pipe diameter of the balanced conditioning plate. This paper will describe the basic balanced flow metering technology, provide performance details generated by testing to date and provide implementation details along with calculations required for differing degrees of flow metering accuracy.

Kelley, Anthony R.↗

Simple transducer measures low heat-transfer rates

A simple transducer is used to measure low rates of convective and conductive heat transfer from a fluid to a cooled surface under steady-state conditions. Temperature drop is measured by two thermocouples imbedded in a rod of low thermal conductivity.

Laumann, E. A.↗

Gaseous hydrogen/oxygen injector performance characterization

Results are presented of spontaneous Raman scattering measurements in the combustion chamber of a 110 N thrust class gaseous hydrogen/oxygen rocket. Temperature, oxygen number density, and water number density profiles at the injector exit plane are presented. These measurements are used as input profiles to a full Navier-Stokes computational fluid dynamics (CFD) code. Predictions of this code while using the measured profiles are compared with predictions while using assumed uniform injector profiles. Axial and radial velocity profiles derived from both sets of predictions are compared with Rayleigh scattering measurements in the exit plane of a 33:1 area ratio nozzle. Temperature and number density Raman scattering measurements at the exit plane of a test rocket with a 1:1.36 area ratio nozzle are also compared with results from both sets of predictions.

Degroot, W. A.↗