At least 595 records · Page 33

Fusion neutron detector for time-of-flight measurements in z-pinch and plasma focus experiments

We have developed and tested sensitive neutron detectors for neutron time-of-flight measurements in z-pinch and plasma focus experiments with neutron emission times in tens of nanoseconds and with neutron yields between 10{sup 6} and 10{sup 12} per one shot. The neutron detectors are composed of a BC-408 fast plastic scintillator and Hamamatsu H1949-51 photomultiplier tube (PMT). During the calibration procedure, a PMT delay was determined for various operating voltages. The temporal resolution of the neutron detector was measured for the most commonly used PMT voltage of 1.4 kV. At the PF-1000 plasma focus, a novel method of the acquisition of a pulse height distribution has been used. This pulse height analysis enabled to determine the single neutron sensitivity for various neutron energies and to calibrate the neutron detector for absolute neutron yields at about 2.45 MeV.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

HOW SOFT GAMMA REPEATERS MIGHT MAKE FAST RADIO BURSTS

There are several phenomenological similarities between soft gamma repeaters (SGRs) and fast radio bursts (FRBs), including duty factors, timescales, and repetition. The sudden release of magnetic energy in a neutron star magnetosphere, as in popular models of SGRs, can meet the energy requirements of FRBs, but requires both the presence of magnetospheric plasma, in order for dissipation to occur in a transparent region, and a mechanism for releasing much of that energy quickly. FRB sources and SGRs are distinguished by long-lived (up to thousands of years) current-carrying coronal arches remaining from the formation of the young neutron star, and their decay ends the phase of SGR/AXP/FRB activity even though “magnetar” fields may persist. Runaway increases in resistance when the current density exceeds a threshold, releases magnetostatic energy in a sudden burst, and produces high brightness GHz emission of FRB by a coherent process. SGRs are produced when released energy thermalizes as an equlibrium pair plasma. The failures of some alternative FRB models and the non-detection of SGR 1806-20 at radio frequencies are discussed in the appendices.

79 ASTRONOMY AND ASTROPHYSICS↗

Pulse shape discrimination in helium-4 scintillation detectors

We investigated three algorithms for discriminating between neutrons and gamma rays in a pres-surized 4 He gas fast neutron detector: charge comparison, weighted integration, and neutron-gamma model analysis (NGMA). And for each algorithm, a comprehensive pulse shape discrimination study was conducted using time-of-flight measurements, receiver operator characteristic curves, figure of merit performance measures, and a comparison of performance between 252 Cf and PuBe mixed neutron/gamma sources. The NGMA method was found to have the best overall performance by both the figure of merit and the receiver operator characteristic curve. Our results also illustrated the high gamma rejection efficiency of these detectors, which is desirable in a variety of neutron monitoring applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Neutron spectroscopy and spectral unfolding with 4 He fast neutron scintillators

Time-of-flight measurements were performed to determine the 4 He pressurized fast neutron scintillation detectors response function and the ability of the detectors to be applied as a spectrometer. An experimentally validated neutron energy response function was used in conjunction with an iterative least squares unfolding technique to unfold a 252 Cf spontaneous fission spectrum, a PuBe (α, n) spectrum, and a deuterium-deuterium (D-D) fusion reaction spectrum. In conclusion, the ability of the detectors to retain incident neutron energies makes them suitable for applications such as nuclear non-proliferation and spent nuclear fuel monitoring.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Data Processing for the SNS EQ-SANS Diffractometer

The scattering data on the Extended Q-Range Small Angle Scattering Diffractometer at the Spallation Neutron Source are stored as neutron events. Each event has two parts: the time of fight of the detected neutron, and an identifier for the neutron's location on the detector. In addition, each event is associated with the source pulse from which the neutron is originated. Due to the high neutron beam intensity at the SNS, the size of the stored data files can easily exceed several Gigabytes. Processing and reducing these data can be very time consuming. The standard way of handling the data at the SNS has been to first transform the data into histograms. On the EQ-SANS, these histograms are further processed into intensity I vs. neutron momentum transfer Q files, I(Q). For a large data, the whole process can take many minutes to hours to complete, which severely limits the turnaround time of an experiment. Experimenters often want to reduce the data quickly and depending on the result, make decisions on the setup of next measurements. They may also need to reduce the data using different inputs and conditions. In this work, we present the implementation of a fast data processing scheme for the EQ-SANS diffractometer. The scattering data are processed directly from neutron event files into I(Q) or other desired formats, greatly reducing the needed computation time. Further speed gains are obtained by the implementation of parallel computing under the Message Passing Interface framework. Most data on the EQ-SANS can now be handled in mere seconds. The process is highly automated. All relevant experimental information that is stored in instrument configuration files are read and processed. In addition, the new implementation is highly flexible. All the data corrections and handlings can be controlled transparently through user inputs. Finally, software implementation enables the slicing of neutron event, which can be used for the study of time dependent phenomena.

Data Processing↗

FAST RADIO BURSTS: COLLISIONS BETWEEN NEUTRON STARS AND ASTEROIDS/COMETS

Fast radio bursts (FRBs) are newly discovered radio transient sources. Their high dispersion measures indicate an extragalactic origin. However, due to the lack of observational data in other wavelengths, their progenitors still remain unclear. Here we suggest that the collisions between neutron stars (NSs) and asteroids/comets are promising mechanisms for FRBs. During the impact process, a hot plasma fireball forms after the material of the small body penetrates into the NS surface. The ionized matter inside the fireball then expands along the magnetic field lines. Coherent radiation from the thin shell at the top of the fireball will account for the observed FRBs. Our scenario can reasonably explain the main features of FRBs, such as their durations, luminosities, and the event rate. We argue that for a single NS, FRBs are not likely to happen repeatedly in a forseeable timespan since such impacts are of low probability. We predict that faint remnant X-ray emissions should be associated with FRBs, but it may be too faint to be detected by detectors at work.

79 ASTRONOMY AND ASTROPHYSICS↗

Gamma ray measurements with photoconductive detectors using a dense plasma focus

Photons in the MeV range emitted from the dense plasma focus (DPF) at the NSTec North Las Vegas Facility have been measured with both neutron-damaged GaAs and natural diamond photoconductive detectors (PCDs). The DPF creates or “pinches” plasmas of various gases (e.g., H{sub 2}, D{sub 2}, Ne, Ar., etc.) that have enough energy to create MeV photons from either bremsstrahlung and/or (n,n{sup ′}) reactions if D{sub 2} gas is used. The high bandwidth of the PCDs enabled the first ever measurement of the fast micro-pinches present in DPF plasmas. Comparisons between a slower more conventional scintillator/photomultiplier tube based nuclear physics detectors were made to validate the response of the PCDs to fast intense MeV photon signals. Significant discrepancies in the diamond PCD responses were evident.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A measurement of the proton’s spin structure function g2 at low Q2

JLab E08-027, a measurement of g2p and the longitudinal-transverse (LT) spin polarizability, successfully collected data from March to May, 2012. Nucleon spin structure study has been an active research area, which has attracted a very large effort from both experimentalists and theorists. The spin structure study for the last 2 decades has provided us with many exciting and often surprising results. Recently, new precision results in the low-to-intermediate momentum transfer Q2 region from JLab have provided extensive information on the nucleon structure in the confinement region and the transition region between asymptotic free to confinement. In particular, the extensive comparisons of experimental results with Chiral Perturbation Theory (the effective theory of QCD at low energy) calculations show general good agreements, but strong disagreement in the case of the neutron LT spin polarizability. This experiment completed the measurements of gp2 and the LT spin polarizability on the proton in the low-to-intermediate Q2 region. The experiment used a polarized proton (NH3) target for the first time in Hall A. Scattered electrons were detected by a pair of Hall A high resolution spectrometer (HRS) with a pair of septum magnets. To avoid too much depolarization of the target, beam current was limited to 50-100 nA during the experiment. Since the existing beam current monitors (BCMs), beam position monitors (BPMs) and calibration methods did not work at such a low current range, new BPM and BCM receivers were designed and used for current condition. A pair of super-harps and a tungsten calorimeter were installed to calibrate the BPMs and BCMs. To compensate for the effect of the 2.5/5T transverse magnet field, two chicane dipole magnets were installed. A pair of slow rasters were installed for the first time in Hall A, combining with a pair of fast raster. The standard Hall A DAQ system and the improved high resolution DAQ system were used to record the detector information and the helicity dependent beam information, respectively. In order to achieve the required accuracy of the beam position and angle and reconstruct them event by event at the target location, the data of the BPMs and harps were carefully analyzed. The final uncertainty of BCM after the calibration using the tungsten calorimeter is below 1%, which is important for the asymmetry extraction. Before the acceptance and the dilution factor are available, the models from fitting to the world data were used instead to extract the unpolarized cross section and the dilution factor. The longitudinal and transverse physics asymmetries were extracted and compared with the model, with the study of the radiative correction. The preliminary g1 and g2 results were then extracted using the measured asymmetry and the model.

Zhu, Pengjia↗

Replacing photomultiplier tubes with silicon photomultipliers for nuclear safeguards applications

Photomultiplier tubes (PMTs) have been used for decades as the default light detection technology for scintillator-based radiation monitors. PMTs come with a handful of disadvantages, however, including large volume usage, fragility, high-voltage requirements, and susceptibility to magnetic fields. Arrays of silicon photomultipliers (SiPMs) are a possible alternative to PMTs providing similar performance while offering improvements in the areas listed. We focus on straightforward “drop-in replacement” evaluations by imposing a single channel output of the SiPM signal and a backend electronics data acquisition and analysis routine identical to that used for PMTs. In the realm of nuclear safeguards, the primary performance metric for gamma spectroscopy is detector resolution, and for neutron detection it is pulse shape discrimination (PSD) to separate neutron and gamma signals. In this work we present the results of replacing a PMT with a 2” x 2” SiPM array mounted, in turn, to the same 2” x 2” cylindrical sodium iodide (NaI) crystal. The ultimate comparison for this gamma spectrometry is confirmation of uranium enrichment standards, ranging from depleted uranium to 93% highly enriched uranium (HEU), by analyzing the resulting spectra with both a simple integral scaling in key energy regions of the spectrum, as well as with the NaIGEM software package. In addition to the gamma spectroscopy work, we will present the latest results on comparing the PSD capabilities of a 4” x 4” SiPM array to a 5” PMT. As with the gamma spectroscopy evaluations, the light detectors are mounted in turn to the same liter-scale organic scintillators. This neutron-focused work includes evaluation of prototype SiPM readout boards with a single output signal summed over 256 individual SiPM pixels, and evident tradeoffs between PSD capability and fast response.

42 ENGINEERING↗

Replacing photomultiplier tubes with silicon photomultipliers for nuclear safeguards applications

Photomultiplier tubes (PMTs) have been used for decades as the default light detection technology for scintillator-based radiation monitors. PMTs come with a handful of disadvantages, however, including large volume usage, fragility, high-voltage requirements, and susceptibility to magnetic fields. Arrays of silicon photomultipliers (SiPMs) are a possible alternative to PMTs providing similar performance while offering improvements in the areas listed. We focus on straightforward “drop-in replacement” evaluations by imposing a single channel output of the SiPM signal and a backend electronics data acquisition and analysis routine identical to that used for PMTs. In the realm of nuclear safeguards, the primary performance metric for gamma spectroscopy is detector resolution, and for neutron detection it is pulse shape discrimination (PSD) to separate neutron and gamma signals. In this work we present the results of replacing a PMT with a 2” x 2” SiPM array mounted, in turn, to the same 2” x 2” cylindrical sodium iodide (NaI) crystal. The ultimate comparison for this gamma spectrometry is confirmation of uranium enrichment standards, ranging from depleted uranium to 93% highly enriched uranium (HEU), by analyzing the resulting spectra with both a simple integral scaling in key energy regions of the spectrum, as well as with the NaIGEM software package. In addition to the gamma spectroscopy work, we will present the latest results on comparing the PSD capabilities of a 4” x 4” SiPM array to a 5” PMT. As with the gamma spectroscopy evaluations, the light detectors are mounted in turn to the same liter-scale organic scintillators. This neutron-focused work includes evaluation of prototype SiPM readout boards with a single output signal summed over 256 individual SiPM pixels, and evident tradeoffs between PSD capability and fast response.

Engineering - Instrumentation related to nuclear s↗

GAMMA-RAY AND HARD X-RAY EMISSION FROM PULSAR-AIDED SUPERNOVAE AS A PROBE OF PARTICLE ACCELERATION IN EMBRYONIC PULSAR WIND NEBULAE

It has been suggested that some classes of luminous supernovae (SNe) and gamma-ray bursts (GRBs) are driven by newborn magnetars. Fast-rotating proto-neutron stars have also been of interest as potential sources of gravitational waves (GWs). We show that for a range of rotation periods and magnetic fields, hard X-rays and GeV gamma rays provide us with a promising probe of pulsar-aided SNe. It is observationally known that young pulsar wind nebulae (PWNe) in the Milky Way are very efficient lepton accelerators. We argue that, if embryonic PWNe satisfy similar conditions at early stages of SNe (in ∼1–10 months after the explosion), external inverse-Compton emission via upscatterings of SN photons is naturally expected in the GeV range as well as broadband synchrotron emission. To fully take into account the Klein–Nishina effect and two-photon annihilation process that are important at early times, we perform detailed calculations including electromagnetic cascades. Our results suggest that hard X-ray telescopes such as NuSTAR can observe such early PWN emission by follow-up observations in months to years. GeV gamma-rays may also be detected by Fermi for nearby SNe, which serve as counterparts of these GW sources. Detecting the signals will give us an interesting probe of particle acceleration at early times of PWNe, as well as clues to driving mechanisms of luminous SNe and GRBs. Since the Bethe–Heitler cross section is lower than the Thomson cross section, gamma rays would allow us to study subphotospheric dissipation. We encourage searches for high-energy emission from nearby SNe, especially SNe Ibc including super-luminous objects.

79 ASTRONOMY AND ASTROPHYSICS↗

Discovery of Fast X-ray Oscillations During the 1998 Giant Flare from SGR 1900+14

We report the discovery of complex high frequency variability during the August 27, 1998 giant flare from SGR 1900+14 using the Rossi X-ray Timing Explorer (RXTE). We detect an approx. equals 84 Hz oscillation (QPO) during a 1 s interval beginning approximately 1 min after the initial hard spike. The amplitude is energy dependent, reaching a maximum of 26% (rms) for photons above 30 keV, and is not detected below 11 keV, with a 90% confidence upper limit of 14% (rms). Remarkably, additional QPOs are detected in the average power spectrum of data segments centered on the rotational phase at which the 84 Hz signal was detected. Two signals, at 53.5 and 155.1 Hz, are strongly detected, while a third feature at 28 Hz is found with lower significance. These QPOs are not detected at other rotational phases. The phenomenology seen in the SGR 1900+14 flare is similar to that of QPOs recently reported by Israel et al. (2005) from the December 27, 2004 flare from SGR 1806-20, suggesting they may have a common origin, perhaps torsional vibrations of the neutron star crust. Indeed, an association of the four frequencies (in increasing order) found in SGR 1900+14 with l = 2, 4, 7, and 13 toroidal modes appears plausible. We discuss our findings in the context of this model and show that if the stars have similar masses then the magnetic field in SGR 1806-20 must be about twice as large as in SGR 1900+14, broadly consistent with estimates from pulse timing.

Strohmayer, T.↗

Numerical investigation of two-dimensional buoyancy-driven eddies in liquid metal magnetohydrodynamic flows in breeding blankets *

Abstract Lead–lithium flows are key features in the design of tokamak breeding blanket concepts such as the dual-coolant lead–lithium (DCLL). Since they flow under magnetic fields, they are affected by magnetohydrodynamic (MHD) effects. The neutron flux originating in the tokamak plasma heats the breeding blanket channels in a non-uniform manner, inducing buoyancy forces in the liquid metal. Buoyancy may become a source of quasi-two-dimensional (Q2D) turbulence, and the appearance of eddies may affect the transport of heat and tritium across the blanket. Blankets characterized by high-speed liquid metal flows (such as DCLL) will need ceramic insulating walls to reduce the MHD-related pressure drop in the channels. In our simulations, we have used the Q2D model proposed by Sommeria and Moreau (SM82) which is especially suitable for modeling electrically insulating channel flows. On top of that, we have modelled buoyancy forces in the momentum equation using the Oberbeck–Boussinesq approximation. In this work, we include a validation of the implemented Q2D model in buoyancy-driven cases and identify a thermohydraulic configuration that promotes the generation of eddies and the accumulation of tritium. We also show the results provided by our post-processing tool based on the bi-dimensional fast Fourier transform for eddy detection and characterization. We complete our investigation by performing an initial assessment of how eddies can accumulate tritium in the breeding blanket. We conclude by discussing the relevance of preventing accumulation of tritium within the blanket and suggest a possible solution.

Suarez, Daniel (ORCID:0000000251740100)↗

New-Generation Thermal Neutron Detectors and Electronics for High-Count-Rate Applications

Neutron measurements are important in many nonproliferation and treaty verification applications. Helium-3 proportional counters and analog electronics are the backbone of neutron detection systems. Helium-3 tubes with a 1-in. diameter have been used with classical electronics for over three decades because of the almost ideal behavior of the 3 He tube as a neutron detector. However, some demanding applications of 3 He tubes (high gamma dose rate, high count rate) and the use of non-ideal detectors (such as 10 B-lined proportional counters) mean that the limitations of these conventional systems are being reached. For example, neutron multiplicity deadtime corrections can be large, and some applications have had trouble with multiple pulsing. Also, instrumentation designs for spent fuel applications often rely on large amounts of lead shielding to reduce the gamma dose at the detector location, making them heavy and expensive. This major challenge for a short dead time and operation in high gamma fields is difficult to address by simply changing the gas admixture and tweaking the shaper time constants. Those small gains are adequate for measurements of some lower-burn-up, low-enrichment-uranium spent fuel assemblies, but not for mixed oxide (MOX) fuel or advanced fast reactor fuel, where the neutron source term is greater.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Pulse shape discrimination performance of stilbene coupled to low-noise silicon photomultipliers

Pulse shape discrimination (PSD) techniques can be used to discern between neutron and gamma-ray interactions in certain organic scintillators. Traditionally, photomultiplier tubes (PMTs) have been used in organic-scintillator assemblies. However, silicon photomultipliers (SiPMs) have great potential to be used in many applications in which PMTs have been predominantly used, including those utilizing PSD techniques. To evaluate the current state of the art of the SiPM technology, SensL's 6-mm B-Series and C-Series SiPMs were compared to a fast Hamamatsu PMT in conjunction with a 6×6×6-mm3 stilbene organic scintillator to assess the PSD performance of the detector assemblies. Measurements with a Cf-252 source were performed and a figure of merit (FOM) for discriminating between neutron and gamma-ray pulses between 100 keVee and 200 keVee was calculated for each assembly. A digital charge-integration PSD technique was used to process all measured data. The FOM for the B-Series SiPM, PMT, and C-Series SiPM was 1.37, 1.93, and 2.13, respectively. The C-Series SiPM was shown to perform as well as the PMT in the experiments.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Radio and X-Ray Observations of the Luminous Fast Blue Optical Transient AT 2020xnd

We present deep X-ray and radio observations of the fast blue optical transient (FBOT) AT 2020xnd/ZTF 20acigmel at z = 0.2433 from 13 days to 269 days after explosion. AT 2020xnd belongs to the category of optically luminous FBOTs with similarities to the archetypal event AT 2018cow. AT 2020xnd shows luminous radio emission reaching L ν ≈ 8 × 10 29 erg s -1 Hz -1 at 20 GHz and 75 days post-explosion, accompanied by luminous and rapidly fading soft X-ray emission peaking at L X ≈ 6 × 10 42 erg s -1 . Interpreting the radio emission in the context of synchrotron radiation from the explosion's shock interaction with the environment, we find that AT 2020xnd launched a high-velocity outflow (v ~ 0.1c–0.2c) propagating into a dense circumstellar medium (effective $\dot{M}\approx {10}^{-3}\,{M}_{\odot }$ yr -1 for an assumed wind velocity of v w = 1000 km s -1 ). Similar to AT 2018cow, the detected X-ray emission is in excess compared to the extrapolated synchrotron spectrum and constitutes a different emission component, possibly powered by accretion onto a newly formed black hole or neutron star. These properties make AT 2020xnd a high-redshift analog to AT 2018cow, and establish AT 2020xnd as the fourth member of the class of optically luminous FBOTs with luminous multiwavelength counterparts.

79 ASTRONOMY AND ASTROPHYSICS↗

The Breakthrough Listen Search For Intelligent Life Near the Galactic Center. I

A line of sight toward the Galactic Center (GC) offers the largest number of potentially habitable systems of any direction in the sky. The Breakthrough Listen program is undertaking the most sensitive and deepest targeted SETI surveys toward the GC. Here, we outline our observing strategies with Robert C. Byrd Green Bank Telescope (GBT) and Parkes telescope to conduct 600 hr of deep observations across 0.7–93 GHz. We report preliminary results from our survey for extraterrestrial intelligence (ETI) beacons across 1–8 GHz with 7.0 and 11.2 hr of observations with Parkes and GBT, respectively. With our narrowband drifting signal search, we were able to place meaningful constraints on ETI transmitters across 1–4 GHz and 3.9–8 GHz with EIRP limits of ≥4 × 10{sup 18} W among 60 million stars and ≥5 × 10{sup 17} W among half a million stars, respectively. For the first time, we were able to constrain the existence of artificially dispersed transient signals across 3.9–8 GHz with EIRP ≥1 × 10{sup 14} W/Hz with a repetition period ≤4.3 hr. We also searched our 11.2 hr of deep observations of the GC and its surrounding region for Fast Radio Burst–like magnetars with the DM up to 5000 pc cm{sup -3} with maximum pulse widths up to 90 ms at 6 GHz. We detected several hundred transient bursts from SGR J1745–2900, but did not detect any new transient bursts with the peak luminosity limit across our observed band of ≥10{sup 31} erg s{sup -1} and burst rate of ≥0.23 burst hr{sup -1}. These limits are comparable to bright transient emission seen from other Galactic radio-loud magnetars, constraining their presence at the GC.

47 OTHER INSTRUMENTATION↗

New method for level-lifetime measurements with thick scintillators

Level lifetimes provide key insight into the structure of atomic nuclei and serve as stringent tests of theoretical descriptions. Though several methods for determining level lifetimes exist for both reaction measurements and decay studies, here the focus is on techniques involving the direct measurement of time differences between population and subsequent depopulation of excited states. The techniques presented herein are broadly applicable across multiple timing ranges, but the approach is specifically described for the βγ timing method. A multi-step, amplitude-dependent time walk correction was employed to address the data analysis complications that arise from using thick scintillators for electron detection. Further, additional corrections for the depth of the interaction must also be performed when the parent isotope has been implanted into the detector. Techniques are presented for performing these time walk and depth of interaction corrections. Subsequently, a new Monte Carlo method utilizing measured detector responses obtained from the data, coupled with chi-square minimization, is presented for extracting excited state lifetimes ≳ 100 picoseconds. The framework of this Monte Carlo method is developed for the decay of a state in 68 Zn with a known 1.6 ps half life, which is considered prompt given the detection sensitivity of the technique, and then benchmarked using two other excited states in neutron-rich Ni isotopes with 120(34) ps and 1.05(3) ns half lives. Using this new method which takes into account the thick scintillator used, these same half lives were measured to be 135(10) ps and 1.04(24) ns, respectively. The overall good agreement demonstrates the validity of the technique.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗