Search NASA⌕ Search

SEARCH · Search NASA

Results for “Filtering techniques”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

Correcting for digital image correlation speckle inversion at high temperature using color cameras

Digital image correlation (DIC) is a popular, noncontacting technique to measure full-field deformation by using cameras to track the motion of an applied surface pattern. Because it is noncontacting, DIC can be performed for extreme temperature applications (e.g., hot-fire rocket testing of carbon composite rocket nozzles) under harsh conditions during which bonded gauges are damaged. Speckle pattern inversion is a phenomenon that sometimes occurs while performing high-temperature DIC. During speckle pattern inversion, portions of the surface pattern that were initially darker at room temperature (e.g., graphite) may emit more light due to blackbody radiation than the portions that were initially paler, thereby producing images in which the pattern appears inverted at high temperature relative to the initial pattern at room temperature. This phenomenon can prevent the correlation algorithm from being able to resolve the displacements between images. This work compares three methods to mitigate speckle pattern inversion: (A) the subtraction method, a recently-published technique in which two high-temperature images are subtracted to remove unwanted light; (B) the filtering method, a popular technique in which optical bandpass filters screen out unwanted light; and (C) the histogram rescaling method, a proposed new method that pairs a color camera with a blue light source and uses information from the green sensor of the camera to correct against inversion in the blue sensor through postprocessing. The histogram rescaling method is shown to successfully eliminate speckle pattern inversion and has the added advantages that it does not require quasi-static loading to be able to compensate for speckle pattern inversion, nor does it impose thick-glass distortions caused by the optical filter.

Rowley, Lindsey J.↗

Optical redshifts of 59 galaxies

This paper presents the results of an observing program carried out to measure galaxy redshifts with the Cassegrain Digicon Spectrograph system on the McDonald Observatory 2.1 m Struve telescope. New redshift determinations are presented for 59 galaxies, obtained for emission line spectra by conventional wavelength determination techniques and for absorption line spectra by Fourier transform filtering and cross correlation techniques with respect to velocity standard spectra of NGC 3115 and NGC 4736. With respect to published redshifts for 29 galaxies, the new redshifts show a mean residual of -1 km/sec and rms residual of 49 km/sec, without apparent systematic trends, from -300 to +13,700 km/sec.

Kelton, P. W.↗

Slit Function Measurement of An Imaging Spectrograph Using Fourier Transform Techniques

Knowledge of a spectrograph slit function is necessary to interpret the unresolved lines in an observed spectrum. A theoretical slit function can be calculated from the sizes of the entrance slit, the detector aperture when it functions as an exit slit, the dispersion characteristic of the disperser, and the point spread function of the spectrograph. A measured slit function is preferred to the theoretical one for the correct interpretation of the spectral data. In a scanning spectrometer with a single exit slit, the slit function is easily measured. In a fixed grating/or disperser spectrograph, illuminating the entrance slit with a near monochromatic light from a pre-monochrmator or a tunable laser and varying the wavelength of the incident light can measure the slit function. Even though the latter technique had been used successfully for the slit function measurements, it had been very laborious and it would be prohibitive to an imaging spectrograph or a multi-object spectrograph that has a large field of view. We explore an alternative technique that is manageable for the measurements. In the proposed technique, the imaging spectrograph is used as a detector of a Fourier transform spectrometer. This method can be applied not only to an IR spectrograph but also has a potential to a visible/UV spectrograph including a wedge filter spectrograph. This technique will require a blackbody source of known temperature and a bolometer to characterize the interferometer part of the Fourier Transform spectrometer. This pa?er will describe the alternative slit function measurement technique using a Fourier transform spectrometer.

Park, Hongwoo↗

Spread Spectrum Digital Communications Modeling in Electronic Warfare Modeling and Simulation Software

This artifact is an intern project poster. The subject matter is modeling spread spectrum digital communications in electronic warfare modeling and simulation software produced by National and Homeland Security. It contains images of communications coverage analysis from the software, link budget terms, and image depicting the Wireless Spectrum Communications (WSComm) underlay control channel (UCC), and an image of a filter bank multicarrier spread spectrum (FBMCSS) signal. INL National and Homeland Security Electronic Warfare Modeling and Simulation software (EWMSS) is capable of modeling several digital and analog signal types, but it does not currently support spread spectrum techniques such as filter bank multicarrier spread spectrum (FBMCSS). FBMCSS modeling requires "processing gain," which is not present in EWMSS' link budget. Wireless Spectrum Communications (WSComm) Underlay Control Channel (UCC), a product of INL, employs FBMCSS and is modeled in EWMSS for this project. This research shows that by manually accounting for FBMCSS processing gain, EWMSS calculates a link margin that is within 0.023 dB of a link margin in an existing WSComm link budget. These link margins were based on free space path loss, an ideal propagation model. EWMSS has the capability to include terrain and other sophisticated propagation models in its calculations, giving it the potential to provide realistic, location-specific models of WSComm UCC if processing gain is accounted for.

97 MATHEMATICS AND COMPUTING↗

The development of a tunable, single-frequency ultraviolet laser source for UV filtered Rayleigh scattering

We present the development of a flexible, high power, narrow line width, tunable ultraviolet source for diagnostic application. By frequency tripling the output of a pulsed titanium-sapphire laser, we achieve broadly tunable (227-360 nm) ultraviolet light with high quality spatial and spectral resolution. We also present the characterization of a mercury vapor cell which provides a narrow band, sharp edge absorption filter at 253.7 nm. These two components form the basis for the extension of the Filtered Rayleigh Scattering technique into the ultraviolet. The UV-FRS system is comprised of four pieces: a single frequency, cw tunable Ti:Sapphire seeding source; a high-powered pulsed Ti:Sapphire oscillator; a third harmonic generator system; and an atomic mercury vapor filter. In this paper we discuss the development and characterization of each of these elements.

Finkelstein, N.↗

Motion detection, novelty filtering, and target tracking using an interferometric technique with a GaAs phase conjugate mirror

A method and apparatus is disclosed for detecting and tracking moving objects in a noise environment cluttered with fast-and slow-moving objects and other time-varying background. A pair of phase conjugate light beams carrying the same spatial information commonly cancel each other out through an image subtraction process in a phase conjugate interferometer, wherein gratings are formed in a fast photo-refractive phase conjugate mirror material. In the steady state, there is no output. When the optical path of one of the two phase conjugate beams is suddenly changed, the return beam loses its phase conjugate nature and the inter-ferometer is out of balance, resulting in an observable output. The observable output lasts until the phase conjugate nature of the beam has recovered. The observable time of the output signal is roughly equal to the formation time of the grating. If the optical path changing time is slower than the formation time, the change of optical path becomes unobservable, because the index grating can follow the change. Thus, objects traveling at speeds which result in a path changing time which is slower than the formation time are not observable and do not clutter the output image view.

Cheng, Li-Jen↗

Motion detection, novelty filtering, and target tracking using an interferometric technique with GaAs phase conjugate mirror

A method and apparatus for detecting and tracking moving objects in a noise environment cluttered with fast- and slow-moving objects and other time-varying background. A pair of phase conjugate light beams carrying the same spatial information commonly cancel each other out through an image subtraction process in a phase conjugate interferometer, wherein gratings are formed in a fast photorefractive phase conjugate mirror material. In the steady state, there is no output. When the optical path of one of the two phase conjugate beams is suddenly changed, the return beam loses its phase conjugate nature and the interferometer is out of balance, resulting in an observable output. The observable output lasts until the phase conjugate nature of the beam has recovered. The observable time of the output signal is roughly equal to the formation time of the grating. If the optical path changing time is slower than the formation time, the change of optical path becomes unobservable, because the index grating can follow the change. Thus, objects traveling at speeds which result in a path changing time which is slower than the formation time are not observable and do not clutter the output image view.

Cheng, Li-Jen↗

Metallic artifact mitigation and organ-constrained tissue assignment for Monte Carlo calculations of permanent implant lung brachytherapy

Purpose: To investigate methods of generating accurate patient-specific computational phantoms for the Monte Carlo calculation of lung brachytherapy patient dose distributions. Methods: Four metallic artifact mitigation methods are applied to six lung brachytherapy patient computed tomography (CT) images: simple threshold replacement (STR) identifies high CT values in the vicinity of the seeds and replaces them with estimated true values; fan beam virtual sinogram replaces artifact-affected values in a virtual sinogram and performs a filtered back-projection to generate a corrected image; 3D median filter replaces voxel values that differ from the median value in a region of interest surrounding the voxel and then applies a second filter to reduce noise; and a combination of fan beam virtual sinogram and STR. Computational phantoms are generated from artifact-corrected and uncorrected images using several tissue assignment schemes: both lung-contour constrained and unconstrained global schemes are considered. Voxel mass densities are assigned based on voxel CT number or using the nominal tissue mass densities. Dose distributions are calculated using the EGSnrc user-code BrachyDose for{sup 125}I, {sup 103}Pd, and {sup 131}Cs seeds and are compared directly as well as through dose volume histograms and dose metrics for target volumes surrounding surgical sutures. Results: Metallic artifact mitigation techniques vary in ability to reduce artifacts while preserving tissue detail. Notably, images corrected with the fan beam virtual sinogram have reduced artifacts but residual artifacts near sources remain requiring additional use of STR; the 3D median filter removes artifacts but simultaneously removes detail in lung and bone. Doses vary considerably between computational phantoms with the largest differences arising from artifact-affected voxels assigned to bone in the vicinity of the seeds. Consequently, when metallic artifact reduction and constrained tissue assignment within lung contours are employed in generated phantoms, this erroneous assignment is reduced, generally resulting in higher doses. Lung-constrained tissue assignment also results in increased doses in regions of interest due to a reduction in the erroneous assignment of adipose to voxels within lung contours. Differences in dose metrics calculated for different computational phantoms are sensitive to radionuclide photon spectra with the largest differences for{sup 103}Pd seeds and smallest but still considerable differences for {sup 131}Cs seeds. Conclusions: Despite producing differences in CT images, dose metrics calculated using the STR, fan beam + STR, and 3D median filter techniques produce similar dose metrics. Results suggest that the accuracy of dose distributions for permanent implant lung brachytherapy is improved by applying lung-constrained tissue assignment schemes to metallic artifact corrected images.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-F-18C-02: Evaluations of the Noise Power Spectrum of a CT Iterative Reconstruction Technique for Radiation Therapy

Purpose: To quantitatively assess the noise power spectrum (NPS) of the new, commercially released CT iterative reconstruction technique, iDose{sup 4} from Philips, to compare it with filtered back-projection techniques (FBP), and to provide clinical practice suggestions for radiation therapy. Methods: A uniform phantom was CT imaged with 120kVp tube potential over a range of mAs (250-3333). The image sets were reconstructed using two reconstruction algorithms (FBP and iDose{sup 4} with noise reduction levels 1, 3, and 6) and three reconstruction filters (standard B, smooth A, and sharp C), after which NPS variations were analyzed and compared on region of interest (ROI) sizes (16×16 to 128×128 pixels), ROI radii (0–65 mm), reconstruction algorithms, reconstruction filters, and mAs. Results: The NPS magnitude and shape depended considerably on ROI size and location for both reconstruction algorithms. Regional noise variance became more stationary as ROI size decreased, minimizing NPS artifacts. The optimal 32×32-pixel ROI size balanced the trade-off between stationary noise and adequate sampling. NPS artifacts were greatest at the center of reconstruction space and decreased with increasing ROI distance from the center. The optimal ROI position was located near the phantom's radial midpoint (∼40mm). For sharper filters, the NPS magnitude and the maximum magnitude frequency increased. Higher dose scans yielded lower NPS magnitudes for both reconstruction algorithms and all filters. Compared to FBP, the iDose{sup 4} algorithm reduced the NPS magnitude while preferentially reducing noise at mid-range spatial frequencies, altering noise texture. This reduction was more significant with increasing iDose{sup 4} noise reduction level. Conclusion: Compared to pixel standard deviation, NPS has greater clinical potential for task-based image quality assessment, describing both the magnitude and spatial frequency characteristics of image noise. While iDose{sup 4} reduces the NPS magnitude more dramatically than FBP, further studies are needed to assess the impacts of noise texture alteration on its clinical usage.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Spent Fuel Assay with an Ultra-High Rate HPGe Spectrometer

Traditional verification of spent nuclear fuel (SNF) includes determination of initial enrichment, burnup and cool down time (IE, BU, CT). Along with neutron measurements, passive gamma assay provides important information for determining BU and CT. Other gamma-ray-based assay methods such as passive tomography and active delayed gamma offer the potential to measure the spatial distribution of fission products and the fissile isotopic concentration of the fuel, respectively. All fuel verification methods involving gamma-ray spectroscopy require that the spectrometers manage very high count rates while extracting the signatures of interest. PNNL has developed new digital filtering and analysis techniques to produce an ultra-high rate gamma-ray spectrometer from a standard coaxial high-purity germanium (HPGe) crystal. This 37% relative efficiency detector has been operated for SNF measurements at input count rates of 500-1300 kcps and throughput in excess of 150 kcps. Optimized filtering algorithms preserve the spectroscopic capability of the system even at these high rates. This paper will present the results of both passive and active SNF measurement performed with this system at PNNL. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Isotopic Analysis of Spent Nuclear Fuel with an Ultra-High Rate HPGe Spectrometer

A longstanding challenge is the assay of spent nuclear fuel (SNF). Determining the isotopic content of SNF requires gamma-ray spectroscopy. PNNL has developed new digital filtering and analysis techniques to produce an ultra high-rate gamma-ray spectrometer from a standard coaxial high-purity germanium (HPGe) crystal. This ~40% efficient detector has been operated for SNF measurements at a throughput of about 400k gamma-ray counts per second (kcps) at an input rate of 1.3 Mcps. Optimized filtering algorithms preserve the spectroscopic capability of the system even at these high rates. This talk will present the results of a SNF measurement with aged SNF pellets at PNNL’s Radiochemical Processing Laboratory, first results with a FPGA front end processor capable of processing the data in real time, and the development path toward a multi-element system to assay fuel assemblies.

Fast, James E.↗

Iterative design of one- and two-dimensional FIR digital filters

The paper describes a new iterative technique for designing FIR (finite duration impulse response) digital filters using a frequency weighted least squares approximation. The technique is as easy to implement (via FFT) and as effective in two dimensions as in one dimension, and there are virtually no limitations on the class of filter frequency spectra approximated. An adaptive adjustment of the frequency weight to achieve other types of design approximation such as Chebyshev type design is discussed.

Suk, M.↗

Damage Detection in Composite Structures with Wavenumber Array Data Processing

Guided ultrasonic waves (GUW) have the potential to be an efficient and cost-effective method for rapid damage detection and quantification of large structures. Attractive features include sensitivity to a variety of damage types and the capability of traveling relatively long distances. They have proven to be an efficient approach for crack detection and localization in isotropic materials. However, techniques must be pushed beyond isotropic materials in order to be valid for composite aircraft components. This paper presents our study on GUW propagation and interaction with delamination damage in composite structures using wavenumber array data processing, together with advanced wave propagation simulations. Parallel elastodynamic finite integration technique (EFIT) is used for the example simulations. Multi-dimensional Fourier transform is used to convert time-space wavefield data into frequency-wavenumber domain. Wave propagation in the wavenumber-frequency domain shows clear distinction among the guided wave modes that are present. This allows for extracting a guided wave mode through filtering and reconstruction techniques. Presence of delamination causes spectral change accordingly. Results from 3D CFRP guided wave simulations with delamination damage in flat-plate specimens are used for wave interaction with structural defect study.

Tian, Zhenhua↗

Conventional modeling of the multilayer perceptron using polynomial basis functions

A technique for modeling the multilayer perceptron (MLP) neural network, in which input and hidden units are represented by polynomial basis functions (PBFs), is presented. The MLP output is expressed as a linear combination of the PBFs and can therefore be expressed as a polynomial function of its inputs. Thus, the MLP is isomorphic to conventional polynomial discriminant classifiers or Volterra filters. The modeling technique was successfully applied to several trained MLP networks.

Chen, Mu-Song↗

Derivative information recovery by a selective integration technique

A nonlinear stationary homogeneous digital filter DIRSIT (derivative information recovery by a selective integration technique) is investigated. The spectrum of a quasi-linear discrete describing function (DDF) to DIRSIT is obtained by a digital measuring scheme. A finite impulse response (FIR) approximation to the quasi-linearization is then obtained. Finally, DIRSIT is compared with its quasi-linear approximation and with a standard digital differentiating technique. Results indicate the effects of DIRSIT on a wide variety of practical signals.

Johnson, M. A.↗

Adaptive mean filtering for noise reduction in CT polymer gel dosimetry

X-ray computed tomography (CT) as a method of extracting 3D dose information from irradiated polymer gel dosimeters is showing potential as a practical means to implement gel dosimetry in a radiation therapy clinic. However, the response of CT contrast to dose is weak and noise reduction is critical in order to achieve adequate dose resolutions with this method. Phantom design and CT imaging technique have both been shown to decrease image noise. In addition, image postprocessing using noise reduction filtering techniques have been proposed. This work evaluates in detail the use of the adaptive mean filter for reducing noise in CT gel dosimetry. Filter performance is systematically tested using both synthetic patterns mimicking a range of clinical dose distribution features as well as actual clinical dose distributions. Both low and high signal-to-noise ratio (SNR) situations are examined. For all cases, the effects of filter kernel size and the number of iterations are investigated. Results indicate that adaptive mean filtering is a highly effective tool for noise reduction CT gel dosimetry. The optimum filtering strategy depends on characteristics of the dose distributions and image noise level. For low noise images (SNR {approx}20), the filtered results are excellent and use of adaptive mean filtering is recommended as a standard processing tool. For high noise images (SNR {approx}5) adaptive mean filtering can also produce excellent results, but filtering must be approached with more caution as spatial and dose distortions of the original dose distribution can occur.

62 RADIOLOGY AND NUCLEAR MEDICINE↗