Search NASA⌕ Search

SEARCH · Search NASA

Results for “Focal plane array”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

Cameras Would Withstand High Accelerations

Very rugged cameras with all-reflective optics proposed for use in presence of high accelerations. Optics consist of four coaxial focusing mirrors in Cassegrain configuration. Mirrors are conics or aspherics. Optics achromatic,and imaging system overall passes light from extreme ultraviolet to far infrared. Charge-coupled-device video camera, film camera, or array of photodetectors placed at focal plane. Useful as portable imagers subject to rough handling, or instrumentation cameras mounted on severely vibrating or accelerating vehicles.

Meinel, Aden B.↗

Manned observations technology development, FY 1992 report

This project evaluated the suitability of the NASA/JSC developed electronic still camera (ESC) digital image data for Earth observations from the Space Shuttle, as a first step to aid planning for Space Station Freedom. Specifically, image resolution achieved from the Space Shuttle using the current ESC system, which is configured with a Loral 15 mm x 15 mm (1024 x 1024 pixel array) CCD chip on the focal plane of a Nikon F4 camera, was compared to that of current handheld 70 mm Hasselblad 500 EL/M film cameras.

Israel, Steven↗

Dynamic Pupil Masking for Phasing Telescope Mirror Segments

A method that would notably include dynamic pupil masking has been proposed as an enhanced version of a prior method of phasing the segments of a primary telescope mirror. The method would apply, more specifically, to a primary telescope mirror that comprises multiple segments mounted on actuators that can be used to tilt the segments and translate them along the nominal optical axis to affect wavefront control in increments as fine as a fraction of a wavelength of light. An apparatus (see figure) for implementing the proposed method would be denoted a dispersed-fringe-sensor phasing camera system (DPCS). The prior method involves the use of a dispersed-fringe sensor (DFS). The prior method was reported as part of a more comprehensive method in Coarse Alignment of a Segmented Telescope Mirror (NPO-20770), NASA Tech Briefs, Vol. 25, No. 4 (April 2001), page 15a. The pertinent parts of the prior method are the following: The telescope would be aimed at a bright distant point source of light (e.g., a star) and form a broadband image on an imaging detector array placed at the telescope focal plane. The construction and use of a dispersed-fringe sensor would begin with insertion of a grism (a right-angle prism with a transmission grating on the hypotenuse face) into the optical path. With other segments tilted away from the investigating region of the detector, a dispersed-fringe image would be formed by use of a designated reference segment and a selected mirror segment. The modulation period and orientation of the fringe would be analyzed to determine the magnitude and sign of the piston error (displacement along the nominal optical axis) between the two segments. The error would be used to perform a coarse-phase piston adjustment of the affected mirror segment. This determination and removing of piston error is what is meant by phasing as used above. The procedure as described thus far would be repeated until all segments had been phased.

Shi, Fang↗

Pseudoslit Spectrometer

The pseudoslit spectrometer is a conceptual optoelectronic instrument that would offer some of the advantages, without the disadvantages, of prior linear-variable etalon (LVE) spectrometers and prior slit spectrometers. The pseudoslit spectrometer is so named because it would not include a slit, but the combined effects of its optical components would include a spatial filtering effect approximately equivalent to that of a slit. Like a prior LVE spectrometer, the pseudoslit spectrometer would include an LVE (essentially, a wedge-like narrowband- pass filter, the pass wavelength of which varies linearly with position in one dimension) in a focal plane covering an imaging planar array of photodetectors. However, the pseudoslit spectrometer would be more efficient because unlike a prior LVE spectrometer, the pseudoslit spectrometer would not have to be scanned across an entire field of view to obtain the spectrum of an object of interest that may occupy only a small portion of the field of view. Like a prior slit spectrometer, the pseudoslit spectrometer could acquire the entire spectrum of such a small object without need for scanning. However, the pseudoslit spectrometer would be optically and mechanically simpler: it would have fewer components and, hence, would pose less of a problem of alignment of components and would be less vulnerable to misalignment.

Reuter, Dennis C.↗

A Near-Infrared and Thermal Imager for Mapping Titan's Surface Features

Approximately 10% of the solar insolation reaches the surface of Titan through atmospheric spectral windows. We will discuss a filter based imaging system for a future Titan orbiter that will exploit these windows mapping surface features, cloud regions, polar storms. In the near-infrared (NIR), two filters (1.28 micrometer and 1.6 micrometer), strategically positioned between CH1 absorption bands, and InSb linear array pixels will explore the solar reflected radiation. We propose to map the mid, infrared (MIR) region with two filters: 9.76 micrometer and 5.88-to-6.06 micrometers with MCT linear arrays. The first will map MIR thermal emission variations due to surface albedo differences in the atmospheric window between gas phase CH3D and C2H4 opacity sources. The latter spans the crossover spectral region where observed radiation transitions from being dominated by thermal emission to solar reflected light component. The passively cooled linear arrays will be incorporated into the focal plane of a light-weight thin film stretched membrane 10 cm telescope. A rad-hard ASIC together with an FPGA will be used for detector pixel readout and detector linear array selection depending on if the field-of-view (FOV) is looking at the day- or night-side of Titan. The instantaneous FOV corresponds to 3.1, 15.6, and 31.2 mrad for the 1, 5, and 10 micrometer channels, respectively. For a 1500 km orbit, a 5 micrometer channel pixel represents a spatial resolution of 91 m, with a FOV that spans 23 kilometers, and Titan is mapped in a push-broom manner as determined by the orbital path. The system mass and power requirements are estimated to be 6 kg and 5 W, respectively. The package is proposed for a polar orbiter with a lifetime matching two Saturn seasons.

Aslam, S.↗

The First Multichroic Polarimeter Array on the Atacama Cosmology Telescope: Characterization and Performance

The Atacama Cosmology Telescope Polarimeter (ACTPol) is a polarization sensitive receiver for the 6-meter Atacama Cosmology Telescope (ACT) and measures the small angular scale polarization anisotropies in the cosmic microwave background (CMB). The full focal plane is composed of three detector arrays, containing over 3000 transition edge sensors (TES detectors) in total. The first two detector arrays, observing at 146 gigahertz, were deployed in 2013 and 2014, respectively. The third and final array is composed of multichroic pixels sensitive to both 90 and 146 gigahertz and saw first light in February 2015. Fabricated at NIST, this dichroic array consists of 255 pixels, with a total of 1020 polarization sensitive bolometers and is coupled to the telescope with a monolithic array of broad-band silicon feedhorns. The detectors are read out using time-division SQUID multiplexing and cooled by a dilution refrigerator at 110 meter Kelvins. We present an overview of the assembly and characterization of this multichroic array in the lab, and the initial detector performance in Chile. The detector array has a TES detector electrical yield of 85 percent, a total array sensitivity of less than 10 microns Kelvin root mean square speed, and detector time constants and saturation powers suitable for ACT CMB observations.

Ho, S. P.↗

Multispectral linear array

The Multispectral Linear Array (MLA) is a solid-state earth imagery radiometer operating in the 'push-broom' mode and using a focal plane containing multiple spectral band linear detector arrays. The MLA sensor offers the capability for increased spatial and spectral resolution with multiple selectable bands and in-orbit operation flexibility. Both free-flyer (satellite) and Shuttle-attached instrument designs have been studied. Four Shuttle-attached MLA instrument design studies were initiated in 1982, and the concepts resulting from these studies are described.

Richard, H. L.↗

The QWIP Focal Plane Assembly for NASA's Landsat Data Continuity Mission

The Thermal Infrared Sensor (TIRS) is a QWIP based instrument intended to supplement the Operational Land Imager (OLI) for the Landsat Data Continuity Mission (LDCM). The TIRS instrument is a dual channel far infrared imager with the two bands centered at 10.8 m and 12.0 m. The focal plane assembly (FPA) consists of three 640x512 GaAs Quantum Well Infrared Photodetector (QWIP) arrays precisely mounted to a silicon carrier substrate that is mounted on an invar baseplate. The two spectral bands are defined by bandpass filters mounted in close proximity to the detector surfaces. The focal plane operating temperature is 43K. The QWIP arrays are hybridized to Indigo ISC9803 readout integrated circuits (ROICs). Two varieties of QWIP detector arrays are being developed for this project, a corrugated surface structure QWIP and a grating surface structure QWIP. This paper will describe the TIRS system noise equivalent temperature difference sensitivity as it affects the QWIP focal plane performance requirements: spectral response, dark current, conversion efficiency, read noise, temperature stability, pixel uniformity, optical crosstalk and pixel yield. Additional mechanical constraints as well as qualification through Technology Readiness Level 6 (TRL 6) will also be discussed.

Jhabvala, M.↗

The QWIP Focal Plane Assembly for NASA's Landsat Data Continuity Mission

The Thermal Infrared Sensor (TIRS) is a QWIP based instrument intended to supplement the Operational Land Imager (OLI) for the Landsat Data Continuity Mission (LDCM). The TIRS instrument is a dual channel far infrared imager with the two bands centered at 10.8[mu]m and 12.0[mu]m. The focal plane assembly (FPA) consists of three 640x512 GaAs Quantum Well Infrared Photodetector (QWIP) arrays precisely mounted to a silicon carrier substrate that is mounted on an invar baseplate. The two spectral bands are defined by bandpass filters mounted in close proximity to the detector surfaces. The focal plane operating temperature is 43K. The QWIP arrays are hybridized to Indigo ISC9803 readout integrated circuits (ROICs). Two varieties of QWIP detector arrays are being developed for this project, a corrugated surface structure QWIP and a grating surface structure QWIP. This paper will describe the TIRS system noise equivalent temperature difference sensitivity as it affects the QWIP focal plane performance requirements: spectral response, dark current, conversion efficiency, read noise, temperature stability, pixel uniformity, optical crosstalk and pixel yield. Additional mechanical constraints as well as qualification through Technology Readiness Level 6 (TRL 6) will also be discussed.

Jhabvala, M↗

The Design, Implementation, and Performance of the Astro-H SXS Calorimeter Array and Anti-Coincidence Detector

The calorimeter array of the JAXA Astro-H (renamed Hitomi) Soft X-ray Spectrometer (SXS) was designed to provide unprecedented spectral resolution of spatially extended cosmic x-ray sources and of all cosmic x-ray sources in the Fe-K band around 6 keV, enabling essential plasma diagnostics. The SXS has a square array of 36 microcalorimeters at the focal plane. These calorimeters consist of ion-implanted silicon thermistors and HgTe thermalizing x-ray absorbers. These devices have demonstrated a resolution of better than 4.5 eV at 6 keV when operated at a heat-sink temperature of 50 mK. We will discuss the basic physical parameters of this array, including the array layout, thermal conductance of the link to the heat sink, resistance function, absorber details, and means of attaching the absorber to the thermistor-bearing element. We will also present the thermal characterization of the whole array, including thermal conductance and crosstalk measurements and the results of pulsing the frame temperature via alpha particles, heat pulses, and the environmental background. A silicon ionization detector is located behind the calorimeter array and serves to reject events due to cosmic rays. We will briefly describe this anti-coincidence detector and its performance.

x-ray calorimeter↗

Focal plane scanner with reciprocating spatial window

A focal plane scanner having a front objective lens, a spatial window for selectively passing a portion of the image therethrough, and a CCD array for receiving the passed portion of the image. All embodiments have a common feature whereby the spatial window and CCD array are mounted for simultaneous relative reciprocating movement with respect to the front objective lens, and the spatial window is mounted within the focal plane of the front objective. In a first embodiment, the spatial window is a slit and the CCD array is one-dimensional, and successive rows of the image in the focal plane of the front objective lens are passed to the CCD array by an image relay lens interposed between the slit and the CCD array. In a second embodiment, the spatial window is a slit, the CCD array is two-dimensional, and a prism-grating-prism optical spectrometer is interposed between the slit and the CCD array so as to cause the scanned row to be split into a plurality of spectral separations onto the CCD array. In a third embodiment, the CCD array is two-dimensional and the spatial window is a rectangular linear variable filter (LVF) window, so as to cause the scanned rows impinging on the LVF to be bandpass filtered into spectral components onto the CCD array through an image relay lens interposed between the LVF and the CCD array.

Mao, Chengye↗

Kalman Filter for Calibrating a Telescope Focal Plane

The instrument-pointing frame (IPF) Kalman filter, and an algorithm that implements this filter, have been devised for calibrating the focal plane of a telescope. As used here, calibration signifies, more specifically, a combination of measurements and calculations directed toward ensuring accuracy in aiming the telescope and determining the locations of objects imaged in various arrays of photodetectors in instruments located on the focal plane. The IPF Kalman filter was originally intended for application to a spaceborne infrared astronomical telescope, but can also be applied to other spaceborne and ground-based telescopes. In the traditional approach to calibration of a telescope, (1) one team of experts concentrates on estimating parameters (e.g., pointing alignments and gyroscope drifts) that are classified as being of primarily an engineering nature, (2) another team of experts concentrates on estimating calibration parameters (e.g., plate scales and optical distortions) that are classified as being primarily of a scientific nature, and (3) the two teams repeatedly exchange data in an iterative process in which each team refines its estimates with the help of the data provided by the other team. This iterative process is inefficient and uneconomical because it is time-consuming and entails the maintenance of two survey teams and the development of computer programs specific to the requirements of each team. Moreover, theoretical analysis reveals that the engineering/ science iterative approach is not optimal in that it does not yield the best estimates of focal-plane parameters and, depending on the application, may not even enable convergence toward a set of estimates.

Kang, Bryan↗

A 2-D Array of Superconducting Magnesium Diboride (MgB2) Far-IR Thermal Detectors for Planetary Exploration

A 2-D array of superconducting Magnesium Diboride(MgB2) far IR thermal detectors has been fabricated. Such an array is intended to be at the focal plane of future generation thermal imaging far-IR instruments that will investigate the outer planets and their icy moons. Fabrication and processing of the pixels of the array as well as noise characterization of architectured MgB2 thin films will be presented. Challenges and solutions for improving the performance of the array will be discussed.

Lakew, Brook↗

Characterization and Performance of a Kilo-TES Sub-Array for ACTPol

ACTPol is a polarization-sensitive receiver upgrade to the Atacama CosmologyTelescope (ACT) which will make millimeterwavelength measurements of the small-scale polarization anisotropies of the cosmic microwave background to investigate the properties of inflation, dark energy, dark matter, and neutrinos in the early Universe. ACTPol will employ three arrays of transition edge sensor (TES) bolometer detectors. The detectors, with a target transition temperature of 150 mK, will be operated at a bath temperature of 100 mK provided by a dilution refrigerator. One array operating at a central frequency of 150 GHz and consisting of 1024 TESes achieved first light at the ACT site in July 2013. We anticipate fielding the remainder of the focal plane, consisting of a second 150 GHz array and a multi-chroic array sensitive to 90 and 150 GHz, at the end of the 2013 observing season. In these proceedings, we present characterization of key detector parameters from measurements performed on the first array both in the lab and during initial field testing. We comment on the design goals, measurements, and uniformity of the detector transition temperatures, saturation powers, and thermal conductivities while detailing measurement methods and results for the detector optical efficiencies and time constants.

neutrinos↗

Fabrication of a Hybrid Transition Edge Sensor Array for Lynx

Lynx is a proposed NASA X-Ray telescope flight mission aimed at achieving state-of-the-art angular and energy resolution with a 100 kilopixel array to probe the hot energetic young universe in unprecedented detail. To achieve these goals, our team plans on leveraging our current work in development of the focal plane for the Athena X-Ray Integral Field Unit (X-IFU) while advancing the state-of-the-art in transition edge sensor (TES) X-ray detector technology. The TES is an optimal technology for achieving both high energy and fine angular resolution at the same time because pixel features can be made extremely small and the absorber which dominates the heat capacity can be tuned to meet resolution requirements. Specifically, the proposed mission concept calls for a hybrid detector of three different arrays fabricated in the same planar process in one focal plane and optimized for different science goals. The main arrays consist of 5x5 hydras, 25 pixels of 4 micron thick Au absorbers each with a different thermal link to one common TES. The outer array has absorbers on a 50-micron pitch for most of the 5 arc-minute field-of-view, and the inner array has 25-micron absorbers for the central 1 arc-minute region. A high resolution array consisting of single pixel 1 micron thick Au absorbers on 50-micron pitch will lie off to the side. Reading out an array of this magnitude will likely require improvements in indium bump bonding to superconducting flexible wiring. Fabrication of absorbers of two different sizes requires electroplating through a photoresist mold by careful tuning of the current density to achieve uniform flat absorbers on a fine pitch scale, followed by ion milling to yield narrow streets separating the pixels while preserving high quantum efficiency. We report on progress made at fabricating the hybrid array with different absorber sizes and thicknesses. Further, we also report on ongoing work to adequately heat sink the pixels with backside wire bonding and copper coating. We also report on work to improve detector pixel yield and top side indium bump bonding to flexible wiring.

Focal plane array↗

BlueSTEAl: A pair of silicon arrays and a zero-degree phoswich detector for studies of scattering and reactions in inverse kinematics

BlueSTEAl, the Blue (aluminum chamber of) Silicon TElescope Arrays for light nuclei, has been developed to study direct reactions in inverse kinematics, as well as scattering and breakup reactions using radioactive ion beams. It is a detector system consisting of a pair of annular silicon detector arrays and a zero-degree phoswich plastic scintillator. For typical binary reaction studies in inverse kinematics, light ions are detected by the Si array in coincidence with heavy recoils detected by the phoswich placed at the focal-plane of a zero-degree magnetic spectrometer. The Si array can also be used to detect light nuclei such as beryllium and carbon with clear isotope separation, while the phoswich can also be placed at zero degrees without a spectrometer and used as a high-efficiency beam counting monitor with particle identification capability at the rate of up to ~5 × 10 4 particles per second. This paper reports on the capabilities of BlueSTEAl as determined by recent experiments performed at the Texas A&M Cyclotron Institute. Furthermore, the device is also anticipated to be used in future experiments at other radioactive ion beam facilities.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Mechanical Design and Development of TES Bolometer Detector Arrays for the Advanced ACTPol Experiment

The next generation Advanced ACTPol (AdvACT) experiment is currently underway and will consist of four Transition Edge Sensor (TES) bolometer arrays, with three operating together, totaling 5800 detectors on the sky. Building on experience gained with the ACTPol detector arrays, AdvACT will utilize various new technologies, including 150 mm detector wafers equipped with multichroic pixels, allowing for a more densely packed focal plane. Each set of detectors includes a feedhorn array of stacked silicon wafers which form a spline pro le leading to each pixel. This is then followed by a waveguide interface plate, detector wafer, back short cavity plate, and backshort cap. Each array is housed in a custom designed structure manufactured from high purity copper and then gold plated. In addition to the detector array assembly, the array package also encloses cryogenic readout electronics. We present the full mechanical design of the AdvACT high frequency (HF) detector array package along with a detailed look at the detector array stack assemblies. This experiment will also make use of extensive hardware and software previously developed for ACT, which will be modi ed to incorporate the new AdvACT instruments. Therefore, we discuss the integration of all AdvACT arrays with pre-existing ACTPol infrastructure.

Advanced ACTPol (AdvACT)↗