Search NASA⌕ Search

SEARCH · Search NASA

Results for “Graphite modeling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

Characterization of runaway electron impact on instrumented sacrificial limiters on DIII-D

Instrumented sacrificial limiter heads, both domed (proud) and flat (flush) are used in DIII-D runaway electron (RE) wall strikes to study the wall impact dynamics with high spatial and time resolution. The approximate structure of the RE wetted area and heating depth on the domed limiter heads were predicted qualitatively using orbit-tracking simulations, although a strong left–right asymmetry (about the magnetic field direction) was not captured well by the simulations. It is hypothesized that this difference is perhaps due to the local 3D magnetic field perturbation of the dome limiter head. The average kinetic energy K and pitch angle θ of REs striking the limiter head were estimated from the spatial distribution of local HXR emission and were estimated to be roughly K ≈ 4 MeV and θ ≈ 0.2 rad. These values are roughly consistent with in-plasma values estimated before the loss event, indicating that RE kinetic energy and pitch angle are not drastically altered when transporting to the wall. Large shot–shot variations (1–10 kJ) in energy deposition into the limiter head were observed and were explained by shot–shot variations in locked magneto-hydrodynamics mode toroidal phase. For the largest deposited energies (10 kJ), graphite material failure and explosive dust release was observed, and the depth of material failure at higher energy deposition was successfully reproduced using modelling of volumetric energy deposition and brittle failure. The presence of energetic (keV) level ion impact during the RE wall strike was confirmed by three different surface analysis techniques. The ratio of energetic ion to RE flux appears to be larger on flat surfaces within the RE wetted area, although the energetic ion flux and total energy flux due to energetic ions have not yet been quantified.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Four-Wave-Mixing Approach to In Situ Detection of Nanoparticles

Here, we report on the development and experimental validation of a laser-based technique which uses coherent Rayleigh-Brillouin scattering (CRBS) to detect nanoparticles with characteristic sizes ranging from the atomic scale to tens of nanometers. This technique is aimed (nonexclusively) at the detection of nanoparticles produced by volumetric nanoparticle synthesis methods. Using CRBS, carbon nanoparticles of dimensions less than 10 nm and concentrations of 10 10 cm –3 are detected in situ in a carbon arc discharge with graphite electrodes. This four-wave-mixing approach should enable advances in the understanding of nanoparticle growth that could potentially lead to improved modeling of the growth mechanisms, and thus to improve synthesis selectivity of nanoparticles and yield.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Investigation of Structure and Reactivity Relationship in M-N-C Type Catalysts using Density Functional Tight Binding

Catalysts inhibition studies were performed to indisputably confirm the role of various metal, carbon, and nitrogen moieties in the individual steps of oxygen reduction reaction (ORR) on M-N-C catalysts. ORR activity was studied at University of New Mexico by rotating ring disk electrode method in the acidic electrolyte with the addition of Tris (tris(hydroxymethyl)-aminomethane) as inhibiting agent. To understand the interaction of Tris with different defects that exist in Fe-N-C materials and provide the support for the experimental data, we used density functional theory (DFT) and modeled the interaction of protonated Tris (TrisH) with Fe containingcenters (Fe-N 4 and Fe-N 2 C 2 ), pyridinic nitrogen, graphitic nitrogen, and pyrrolic nitrogen both as in plane and edge defects.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Stability margin analysis of the Holos-quad microreactor design

A simplified point model of the Holos-Quad microreactor is introduced. The model is based on the point kinetics equations coupled to three heat balance equations, representing the mean temperatures of the fuel particles, the graphite moderator and the helium coolant. The differential equations are converted to the frequency domain, enabling the construction of the closed-loop reactor transfer function. Using this function the stability margins of the core design is analyzed for various power levels. It is shown that the gain margins approaches infinity, demonstrating the stability of the reactor for all power levels. The phase margin at nominal power is about 60 degrees, however it shows a non-monotonous dependence on power, with minimal value obtained for about 10% of nominal power. As power level is further increased, the phase margin also increases, demonstrating the reactor becomes more stable. This behavior may be of high importance in load-follow scenarios, where the power level of the reactor changes with time. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Development of the TREAT M2 experiment as a transient benchmark

A transient benchmark based on the Transient Reactor Test Facility (TREAT) M2 Calibration experiment (M2-CAL) is under development. TREAT, at Idaho National Laboratory, is a graphite moderated air-cooled research reactor which has been used extensively for fuel material testing under extreme and accident conditions. Accurate benchmark models are a beneficial component in the operations, experimental planning, and development of TREAT. In this work, we present a transient benchmark model for the M2-CAL experiment core loading. The benchmark model incorporates the coupling between the Monte Carlo Code SERPENT and the computational fluid dynamics code OpenFOAM to capture the temperature feedback mechanism. The M2-CAL transient 2580 was simulated in this work. A pre-transient analysis was performed to determine the optimum core composition and conditions before the beginning of the transient. The analysis was validated against historic TREAT kinetic measurements and the worth of the transient rod T-2. The axial power distribution in the flux wire for the M2-CAL experiment was determined and contrasted with the experiment. The model was then used to simulate the M2-CAL transient 2580 experiment based on the reported pre-transient and transient conditions. Several transient observables were calculated and compared to the experiment. The model shows good agreement with the experimental power traces, period, and average increase of power at the power ramp (time > 7.8 s). Inverse point kinetics analysis was performed during the period of the power ramp for the model and the experiment based on that, the temperature feedback component was isolated and contrasted with the experimental feedback. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Phase change material-to-refrigerant heat exchangers: Experimental validation and uneven melting analysis

Thermal energy storage (TES) using phase change materials (PCMs) enables load shifting and reduces mismatches between the building's thermal demand and the heat pump (HP) system's thermal capacity. While most TES studies have focused on single-phase heat transfer fluids, PCM-to-refrigerant heat exchangers (PRHX), in which the refrigerant undergoes liquid-vapor phase change, remain largely underexplored. Here, to address this gap, this study systematically investigates a shell-and-tube PRHX operating as the condenser in an HP through experiments and simulations. A two-dimensional enthalpy-based finite-volume PRHX model was developed and validated against experimental data, including refrigerant and PCM temperature profiles, PRHX capacity, and system-level performance. Results show three characteristic stages: Stage I, the condenser temperature rapidly increases with PCM in the solid state absorbing sensible heat; Stage II, stable operation during PCM phase change; and Stage III, performance decline once part of the PCM becomes fully melted. Heat transfer analysis revealed that uneven PCM melting along the condenser length was driven primarily by variations in the refrigerant-side heat transfer coefficient, rather than local approach temperature differences. Further study demonstrated that minimizing refrigerant outlet subcooling led to more uniform PCM melting and extended Stages I and II by up to 89%. This paper provides a validated PRHX model, clarifies the mechanisms of uneven PCM melting, and highlights subcooling control as an effective strategy to improve TES performance in HP systems without requiring secondary loops.

Graphite matrix↗

Experiment-modeling studies comparing energy dissipation in the DIII-D SAS and SAS-VW divertors

Recent DIII-D experiments on Small Angle Slot (SAS) divertors have confirmed that a combination of divertor closure and target shaping can enhance cooling across the divertor target and increase energy dissipation, but with significant dependence on B T (toroidal magnetic field) direction. In these novel divertors, the roles of closure, target shaping, drifts, and scale lengths are all interconnected in optimizing dissipation, with the separatrix electron density n eSEP being the key parameter associated with the level of dissipation/detachment. After modifying the original flat-targeted graphite SAS to include a V shape with a tungsten coating on the outer side of the divertor (SAS-VW), matched series of discharges were run to compare to detailed SOLPS-ITER modeling. Experimentally, when run as designed with the outer strike point at the slot vertex, SAS-VW requires nearly identical n eSEP for detachment as the original SAS, with little difference in dissipation for the new geometry. This is in contrast to (1) earlier modeling predictions that a small change of the SAS geometry to a V shape should enhance dissipation at the same n eSEP for magnetic configurations having better H-mode access (ion B × ∇B drift directed into the divertor), and (2) despite the achievement of significantly higher (2-7x) neutral pressures and compression in the SAS-VW slot. Comparisons of experimental density scans to the most recent SOLPS-ITER modeling with ExB drifts show reasonable agreement for dissipation/detachment onset when using separatrix density as the independent parameter. In order to help understand the discrepancy in modeled vs actual performance for the new configuration, additional measurements varying gas injection location and impurity injection were undertaken. In-slot D 2 gas fueling is more effective (5–22 %) in promoting detachment, in accord with modeling. In-slot impurity injection (N 2 or Ne) can yield 30 % lower core Z eff and 15 % less confinement degradation after detachment compared to main chamber puffing, as well as relatively lower tungsten leakage from the divertor. Modeling can also reproduce the improved detachment seen as the strike point moves inboard of the slot vertex. While we can explain the effects of the most important parameters causing energy dissipation in these slot divertors, it remains that many aspects of their behavior cannot be accurately modeled using state-of-art codes such as SOLPS-ITER. This is of concern for future model-driven designs utilizing similar V-shaped geometries.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Combined experimental and numerical evaluation of a prototype nano-PCM enhanced wallboard

In the United States, forty-eight (48) percent of the residential end-use energy consumption is spent on space heating and air conditioning. Reducing envelope-generated heating and cooling loads through application of phase change material (PCM)-enhanced building envelopes can facilitate maximizing the energy efficiency of buildings. Combined experimental testing and numerical modeling of PCM-enhanced envelope components are two important aspects of the evaluation of their energy benefits. An innovative phase change material (nano-PCM) was developed with PCM encapsulated with expanded graphite (interconnected) nanosheets, which is highly conductive for enhanced thermal storage and energy distribution, and is shape-stable for convenient incorporation into lightweight building components. A wall with cellulose cavity insulation and prototype PCM-enhanced interior wallboards was built and tested in a natural exposure test (NET) facility in a hot-humid climate location. The test wall contained PCM wallboards and regular gypsum wallboard, for a side-by-side annual comparison study. Further, numerical modeling of the walls containing the nano-PCM wallboard was performed to determine its actual impact on wall-generated heating and cooling loads. The model was first validated using experimental data, and then used for annual simulations using Typical Meteorological Year (TMY3) weather data. This article presents the measured performance and numerical analysis evaluating the energy-saving potential of the nano-PCM-enhanced wallboard.

finite element analysis↗

Polarity effects and apparent ion recombination in microionization chambers

Purpose: Microchambers demonstrate anomalous voltage-dependent polarity effects. Existing polarity and ion recombination correction factors do not account for these effects. As a result, many commercial microchamber models do not meet the specification of a reference-class ionization chamber as defined by the American Association of Physicists in Medicine. The purpose of this investigation is to determine the cause of these voltage-dependent polarity effects. Methods: A series of microchamber prototypes were produced to isolate the source of the voltage-dependent polarity effects. Parameters including ionization-chamber collecting-volume size, stem and cable irradiation, chamber assembly, contaminants, high-Z materials, and individual chamber components were investigated. Measurements were performed with electrodes coated with graphite to isolate electrode conductivity. Chamber response was measured as the potential bias of the guard electrode was altered with respect to the collecting electrode, through the integration of additional power supplies. Ionization chamber models were also simulated using COMSOL Multiphysics software to investigate the effect of a potential difference between electrodes on electric field lines and collecting volume definition. Results: Investigations with microchamber prototypes demonstrated that the significant source of the voltage-dependent polarity effects was a potential difference between the guard and collecting electrodes of the chambers. The voltage-dependent polarity effects for each prototype were primarily isolated to either the guard or collecting electrode. Polarity effects were reduced by coating the isolated electrode with a conductive layer of graphite. Polarity effects were increased by introducing a potential difference between the electrodes. COMSOL simulations further demonstrated that for a given potential difference between electrodes, the collecting volume of the chamber changed as the applied voltage was altered, producing voltage-dependent polarity effects in the chamber response. Ionization chamber measurements and COMSOL simulations demonstrated an inverse relationship between the chamber collecting volume size and the severity of voltage-dependent polarity effects on chamber response. The effect of a given potential difference on chamber polarity effects was roughly ten times greater for microchambers as compared to Farmer-type chambers. Stem and cable irradiations, chamber assembly, contaminants, and high-Z materials were not found to be a significant source of the voltage-dependent polarity effects. Conclusions: A potential difference between the guard and collecting electrodes was found to be the primary source of the voltage-dependent polarity effects demonstrated by microchambers. For a given potential difference between electrodes, the relative change in the collecting volume is smaller for larger-volume chambers, illustrating why these polarity effects are not seen in larger-volume chambers with similar guard and collecting electrode designs. Thus, for small-volume chambers, it is necessary to reduce the potential difference between the guard and collecting electrodes in order to reduce polarity effects for reference dosimetry measurements.

60 APPLIED LIFE SCIENCES↗

Design and performance evaluation of a dual-circuit thermal energy storage module for air conditioners

We present experimental results and a validated numerical model of a dual-circuit phase-change thermal energy storage module for air conditioners. The module incorporates a phase-change material encapsulated in compressed expanded natural graphite foam. We used n-tetradecane as the PCM with a transition temperature (~4.5 °C) suitable for air-conditioning applications. Heat exchange to and from the module is accomplished through two fluid loops operating as a heat source and sink embedded inside multiple slabs of the composite material. This dual-circuit design enables easier integration with air-conditioning equipment and provides enhanced flexibility in system operation as compared to the state-of-the-art thermal storage systems. When integrated with an air-conditioner, this design will enable peak-load shaving and enhances operational efficiency. The thermal storage device was designed for a nominal storage capacity of ~ 3.5 kWh. We evaluated the heat transfer and energy storage performance of this device using standalone heat transfer experiments to estimate key thermal resistances and identify design improvements before integration with an air conditioner. The numerical model of the heat exchanger uses a combination of discretized and lumped parameter approaches to maintain a balance between accuracy and computational expense. Our analyses show that the geometric features and integration of fluid tubes are key contributors to the thermal contact resistance between the fluid and the thermal storage material, and consequently, to the overall performance of the thermal storage module. Our standalone experiments also identified important operating scenarios in which this thermal storage module can be used for air-conditioning in buildings.

25 ENERGY STORAGE↗

Unraveling compacted graphite evolution during solidification of cast iron using in-situ synchrotron X-ray tomography

In spite of many years of research, the physical phenomena leading to the evolution of compacted graphite (CG) during solidification is still not fully understood. In particular, it is unknown how highly branched CG aggregates form and evolve in the semi-solid, and how local microstructural variations at micrometer length scale affect this growth process. We present here the first time-resolved synchrotron tomography combined with a bespoke high-temperature environmental cell that allows direct observation of the evolution of CG and relates this dynamic process to the local surrounding microstructures in a cast iron sample during repeated melting and solidification. Distinct processes are identified for the formation of CG involving the nucleation, growth, development of branches and interconnection of graphite particles, ultimately evolving into highly branched graphite aggregates with large sizes and low sphericities. CG is found to nucleate with a spheroidal or a plate-like shape, developing branches induced by high carbon concentration, e.g. thin melt channels. Additionally, CG grows much faster than spheroidal graphite during subsequent cooling in solid state. The direct visualization of the dynamic solidification process provides unprecedented new insights into formation mechanisms of CG and correlating factors such as local microstructural variations, and guides the development of CG iron solidification models.

36 MATERIALS SCIENCE↗

A combined SECM and electrochemical AFM approach to probe interfacial processes affecting molecular reactivity at redox flow battery electrodes

Redox flow batteries are attractive technologies for grid energy storage since they use solutions of redox-active molecules that enable a superior scalability and the decoupling of power and energy density. However, the reaction mechanisms of the redox active components at RFB electrodes are complex, and there is currently a pressing need to understand how interfacial processes impact the kinetics and operational reversibility of RFB systems. Here, we developed a combined electrochemical imaging methodology rooted in scanning electrochemical microscopy (SECM) and atomic force microscopy (AFM) for exploring the impact of electrode structure and conditioning on the electron transfer properties of model redox-active dialkoxybenzene derivatives, 2,5-di-tert-butyl-1,4-bis(2-methoxyethoxy)benzene (C1) and 2,3-dimethyl-1,4-dialkoxybenzene (C7). Using AFM and secondary-ion mass spectrometry (SIMS), we observed the formation of interfacial films with distinct mechanical properties compared to those of cleaved graphitic surfaces, and exclusively during reduction of electrogenerated radical cations. These films had an impact on the median rate and distribution of the electron transfer rate constant at the basal plane of multilayer and single layer graphene electrodes, displaying kinetically-limited values that did not yield the activation expected per the Butler–Volmer model with a transfer coefficient ~0.5. These changes were dependent on redoxmer structure: furthermore, SECM showed strong attenuation of C7 kinetics by a surface layer on MLG and SLG, while C1 kinetics were only affected by SLG. SECM and AFM results together show that these limiting films operate exclusively on the basal plane of graphite, with the edge plane showing a relative insensitivity to cycling and operation potential. Ultimately, this integrated electrochemical imaging methodology creates new opportunities to understand the unique role of interfacial processes on the heterogeneous reactivity of redoxmers at electrodes for RFBs, with a future role in elucidating phenomena at high active concentrations and spatiotemporal variations in electrode dynamics.

25 ENERGY STORAGE↗

Structural Characterization of Loblolly Pine Derived Biochar by X-ray Diffraction and Electron Energy Loss Spectroscopy

Biochar from lignocellulosic biomass is emerging as a sustainable material with versatile applications, but its detailed properties are poorly understood because of its structural complexity. We propose a biochar structural development model based on experimental results including composition analysis, surface area and pore analysis, X-ray diffraction analysis, electron microscopy imaging, and electron energy loss spectroscopy. Loblolly pine derived biochars were produced at different carbonization temperatures between 300 to 1000 °C. Fixed carbon, sp 2 content, and number of graphene layers increased with increased carbonization temperature. Alternating average C–C bond length, interlayer spacing distance, and layer coherence length were observed. Bulk plasmon excitation energy was correlated to the average C–C bond length, and it serves as a good indicator of the carbon structure development when compared to the perfect graphitic carbon structure. On the basis of the experimental results, four different structural development phases are identified, which provide a comprehensive understanding of biochar nanocarbon crystallite development. Unlike previous biochar structure models, which proposed radially growing polyaromatic carbon crystallite, we propose a lengthwise growing polyaromatic carbon crystallite model. Furthermore, this experiment-based biochar model should be helpful when determining the structure of unknown biomass-derived carbon materials and disordered pyrolytic carbon materials.

Biomass carbonization↗

Measurement of temperature and density using non-collective X-ray Thomson scattering in pulsed power produced warm dense plasmas

We present the first experimental measurement of temperature and density of a warm dense plasma produced by a pulsed power driver at the Nevada Terawatt Facility (NTF). In the early phases of discharge, most of the mass remains in the core, and it has been challenging to diagnose with traditional methods, e.g. optical probing, because of the high density and low temperature. Accurate knowledge of the transport coefficients as well as the thermodynamic state of the plasma is important to precisely test or develop theoretical models. Here, we have used spectrally resolved non-collective X-ray Thomson scattering to characterize the dense core region. We used a graphite load driven by the Zebra current generator (0.6 MA in 200 ns rise time) and the Ti He-α line produced by irradiating a Ti target with the Leopard laser (30 J, 0.8 ns) as an X-ray probing source. Using this configuration, we obtained a signal-to-noise ratio ~2.5 for the scattered signal. Finally, by fitting the experimental data with predicted spectra, we measured T = 2±1.9 eV, ρ = 0.6±0.5 gr/cc, 70 ns into the current pulse. The complexity of the dense core is revealed by the electrons in the dense core that are found to be degenerate and weakly coupled, while the ions remain highly coupled.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Atmospheric pressure arc discharge with ablating graphite anode

The anodic carbon arc discharge is used to produce carbon nanoparticles. Recent experiments with the carbon arc at atmospheric pressure helium demonstrated the enhanced ablation rate for narrow graphite anodes resulting in high deposition rates of carbonaceous products on the copper cathode (Fetterman et al 2008 Carbon 46 1322–6). The proposed model explains these results with interconnected steady-state models of the cathode and the anode processes. When considering cathode functioning, the model predicts circulation of the particles in the near-cathode region: evaporation of the cathode material, ionization of evaporated atoms and molecules in the near-cathode plasma, return of the resulting ions to the cathode, surface recombination of ions and electrons followed again by cathode evaporation etc. In the case of the low anode ablation rate, the ion acceleration in the cathode sheath provides the major cathode heating mechanism. In the case of an intensive anode ablation, an additional cathode heating is due to latent fusion heat of the atomic species evaporated from the anode and depositing at the cathode. Using the experimental arc voltage as the only input discharge parameter, the model allows us to calculate the anode ablation rate. A comparison of the results of calculations with the available experimental data shows reasonable agreement.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Time-Resolved X-ray Operando Observations of Lithiation Gradients across the Cathode Matrix and Individual Oxide Particles during Fast Cycling of a Li-Ion Cell

Lithiated transition metal oxides serve as active materials in the positive electrode (cathode) of lithium-ion cells. During electrochemical cycling, lithium ions intercalate and deintercalate into these oxide particles. This behavior causes two types of lithiation gradients to emerge: (i) a bulk gradient across the depth of the cathode matrix (averaged over individual oxide particles) and (ii) a microscopic gradient across the particles themselves, which also depends on their location in the electrode. Here we show how both gradients can be studied using operando X-ray diffraction during 4C charge and 4C discharge. The oxide (de)lithiation is estimated from the unit cell parameters by indexing the X-ray diffraction spectra. By fitting the lithiation profiles with orthogonal polynomials, the bulk gradients across the electrode thickness are quantified. These gradients develop as the current flows through the cell and dissipate during open-circuit and potentiostatic-hold periods. Further details of lithiation dynamics can be obtained through shape analysis of the Bragg peaks. In particular, from electrochemical model simulations, we show that the width and skewness of the (003) peak track (de)lithiation fronts moving across the individual oxide particles.

(003) peak↗

Summary of the 1st Reactor Graphite Workshop, 8-9 July, 2025

Graphite is widely used as moderator in many fission reactors and other criticality systems. The understanding of its short- and long-term behavior in fission environments is crucial not only for the operation and optimization of existing reactors but also for the efficient design and safe deployment of future advanced reactors. It is thus of utmost importance to incorporate in nuclear data libraries accurate evaluations of the interaction of thermal neutrons with graphite used in applications. This is however a complex task as there are challenges in defining the detailed characterizations of the studied material, appropriate modeling, and optimal validation suite. This will only be achieved by the concerted effort of experts of all relevant areas.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗