Search NASA⌕ Search

SEARCH · Search NASA

Results for “Histogram”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

Dose Summation Strategies for External Beam Radiation Therapy and Brachytherapy in Gynecologic Malignancy: A Review from the NRG Oncology and NCTN Medical Physics Subcommittees

Definitive, nonsurgical management of gynecologic malignancies involves external beam radiation therapy (EBRT) and/or brachytherapy (BT). Summation of the cumulative dose is critical to assess the total biologic effective dose to targets and organs at risk. Cumulative dose calculation from EBRT and BT can be performed with or without image registration (IR) and biologic dose summation. Among these dose summation strategies, linear addition of dose-volume histogram (DVH) parameters without IR is the global standard for composite dose reporting. This approach stems from an era without image guidance and simple external beam and brachytherapy treatment approaches. With technological advances, EBRT and high-dose-rate BT have evolved to allow for volume-based treatment planning and delivery. Modern conformal therapeutic radiation involves volumetric or intensity modulated EBRT, capable of simultaneously treating multiple targets at different specified dose levels. Therefore, given the complexity of modern radiation treatment, the linear addition of DVH parameters from EBRT and high-dose-rate BT is challenging to represent the combined dose distribution. Deformable image registration (DIR) between EBRT and image guided brachytherapy (IGBT) data sets may provide a more nuanced calculation of multimodal dose accumulation. However, DIR is still nascent in this regard, and needs further development for accuracy and efficiency for clinical use. Biologic dose summation can combine physical dose maps from EBRT and each IGBT fraction, thereby generating a composite DVH from the biologic effective dose. However, accurate radiobiologic parameters are tissue-dependent and not well characterized. A combination of voxel-based DIR and biologic weighted dose maps may be the best approximation of dose accumulation but remains invalidated. The purpose of this report is to review dose summation strategies for EBRT and BT, including conventional equivalent dose in 2-Gy fractions dose summation without image registration, physical dose summation using 3-dimensional rigid IR and DIR, and biologic dose summation. We also provide general clinical workflows for IGBT with a focus on cervical cancer.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Investigations of element spatial correlation in Mn-promoted Co-based Fischer–Tropsch synthesis catalysts

Making connections between performance and structure in bimetallic catalysts requires knowledge of how the two elements are spatially associated. Elemental maps obtained by analytical TEM methods are an invaluable tool for identifying the location of different elements, but for many samples, visual inspection of elemental maps is insufficient for assessing the degree of element spatial correlation. This is particularly true for beam-sensitive materials where short mapping acquisition times lead to images with high noise and low color depth. In these situations, statistical analysis of elemental maps can be used to identify spatial correlations among the elements in a sample. In this work, the relationship between catalyst performance and bimetallic spatial association was explored using Mn-promoted Co-based Fischer-Tropsch synthesis catalysts prepared by different pretreatment methods. Mn was used as a catalyst additive to suppress methane formation. Catalysts that underwent calcination before reduction produced more methane and fewer long-chain hydrocarbons than catalysts that were directly reduced. The extent to which Co and Mn were spatially associated was assessed using correlation metrics, colocation plots, and histograms generated using data from STEM-EDS maps. Although both catalysts yielded visually similar elemental maps, the results of statistical analysis suggested that the calcined catalyst exhibited greater spatial segregation between the Co and Mn. These findings support the hypothesis that having Mn in close proximity to the Co is essential for the manifestation of Mn promotion effects in Co-based FTS catalysts.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

An Electron Backscatter Diffraction Analysis of Grain Boundary Initiated Discontinuous Precipitation in U-10Mo

The effect of varied thermomechanical processing on discontinuous precipitation (DP) in U-10Mo was investigated, with specific emphasis on understanding the role of grain boundary misorientation in DP. Varied prior homogenization heat treatment and thermomechanical processing resulted in differences in both the fraction of DP and the colony width, and was attributed to variations in the grain boundary misorientation distribution. Regardless of the degree of DP-based transformation, extensive growth of DP colonies was dominant on 30°–45° misorientation boundaries. Interestingly, misorientation histograms of the deformed and annealed specimens suggest the processing steps involved may have inhibited DP colony growth along a small fraction of these high angle boundaries. Large-area electron backscatter diffraction montages coupled with high resolution mapping suggest symmetric {110}-type interfaces may be important considerations for mitigating extensive DP growth in this alloy system.

Discontinuous Precipitation, Uranium, Electron Bac↗

Uranium Oxide Synthetic Pathway Discernment through Unsupervised Morphological Analysis

We present a novel unsupervised machine learning method for quantitative representation of scanning electron micrographs and its applications and performance for nuclear forensic analysis of uranium ore concentrates. The method uses a vector quantizing variational autoencoder followed by a histogram operation to encode a micrograph into a single dimensional representation, called the latent vector. The method requires no extant labeling of the data and can be applied over large datasets of micrographs with minimal human interaction. The representations generated are broadly descriptive of each micrograph and the microstructure of the material imaged. In the case of uranium ore concentrate analysis, the representations were amenable to processing reagent and ore concentrate species classification with accuracy of 81:8%, which is competitive with state-of-the-art supervised networks. The representations were also used to classify previously unseen processing routes, were able to classify imaging parameters such as magnification (to 76:0% accuracy), were able to classify fine grained process parameters such as calcining temperature (to 74:4% accuracy), and their informatic properties indicate that they are generally descriptive of the image represented. This method can be applied across microstructure analysis fields to perform quantitative analysis without the need for labor intensive and possibly biased human analysis.

Scanning Electron Microscopy, Vector Quantizing Va↗

Prediction of electric and magnetic fields from spectral data using machine learning algorithms for Doppler-free saturation spectroscopy diagnostics

The prediction of electric and magnetic field amplitudes from atomic spectral data is critical for plasma control in fusion devices such as tokamaks. Conventional approaches that rely on physics-based models are computationally expensive and unsuitable for real-time applications. In this work, we develop and benchmark three machine learning algorithms—simulation-based inference (SBI), fully connected neural networks (FCNN), and histogram-based gradient boosting regression (GBR-Hist)—to infer field intensities directly from Doppler-free saturation spectroscopy (DFSS) spectra. Synthetic datasets of spectra were generated using the EZSSS code and evaluated both with and without added Poisson noise to mimic experimental conditions. We find that SBI achieves the highest accuracy and robustness, FCNN provides a strong balance of accuracy and computational efficiency for real-time applications, and GBR-Hist offers the fastest inference but is more sensitive to noise. Furthermore, these results demonstrate the potential of machine learning to accelerate DFSS analysis and enhance its utility for plasma diagnostics and control.

Doppler-free saturation spectroscopy↗

Low-temperature synthesis, luminescence and phonon properties of Er and/or Dy doped LaAlO{sub 3} nanopowders

LaAlO{sub 3}, La{sub 0.9}Dy{sub 0.1}AlO{sub 3}, La{sub 0.9}Er{sub 0.1}AlO{sub 3} and La{sub 0.8}Dy{sub 0.1}Er{sub 0.1}AlO{sub 3} nanocrystalline powders were synthesized in a two-step process by combining a mechanically induced metathesis reaction and molten salt synthesis. The proposed two-step methodology easily allows obtaining pure and/or doped perovskite-type LaAlO{sub 3} nanopowders at remarkably low temperatures, i.e., already at 350 Degree-Sign C although firing at 500 Degree-Sign C is needed in order to get pure phases. The obtained samples were characterized by XRD, TEM, Raman, IR and luminescence methods. These methods showed that the mean crystallite size is near 50-60 nm and the LaAlO{sub 3} nanocrystallites have R3{sup Macron }c structure, the same as bulk LaAlO{sub 3}. Raman spectrum of nanocrystalline LaAlO{sub 3} is very similar to that of bulk. In contrast to this behavior, IR spectra of the synthesized compounds are significantly different from the IR spectrum of bulk LaAlO{sub 3}. Origin of this behavior is discussed. Luminescence study showed that the cross-relaxation processes quench emission intensity of the samples doped with Dy{sup 3+} and Er{sup 3+}. - Graphical abstract: TEM image of La{sub 0.9}Er{sub 0.1}AlO{sub 3} (left panel) and histogram showing the particle size distribution (right panel). Highlights: Black-Right-Pointing-Pointer Pure and Er or Dy doped LaAlO3 samples were synthesized at remarkably low temperatures. Black-Right-Pointing-Pointer The mean crystallite size of the obtained samples is 40-60 nm. Black-Right-Pointing-Pointer Nanocrystallites have R3{sup Macron }c structure, the same as bulk LaAlO3. Black-Right-Pointing-Pointer IR spectra are significantly different from the IR spectrum of bulk. Black-Right-Pointing-Pointer We discuss origin of this behavior.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Electronic and transport properties of polycrystalline Ba{sub 8}Ga{sub 15}Ge{sub 31} type I clathrate prepared by SPS method

Samples of germanium Ba{sub 8}Ga{sub 15}Ge{sub 31} clathrate of type I were prepared using standard metallurgy methods. The structure, microstructure and phase composition of the prepared samples were analyzed by powder X-ray diffraction XRD and scanning electron microscope SEM combined with energy dispersive X-ray analysis EDX. Scanning thermoelectric microprobe STMP was used to characterize uniformity of Seebeck coefficient distribution at different stages of the material synthesis in order to optimize the synthesis method. Electrical conductivity, Seebeck coefficient and thermal conductivity were measured in the temperature range 20-450 Degree-Sign C. Based on the measured electrical properties and Hall carrier concentration n=5-9{center_dot}10{sup 20} cm{sup -3} at room temperature, electron effective mass m{sup Low-Asterisk} was estimated to be between 2.1-3 m{sub 0}. Preliminary FP-LAPW DFT calculations were performed for two chosen high symmetry superstructures Ba{sub 8}Ga{sub 16}Ge{sub 30} and Ba{sub 8}Ga{sub 6}Ge{sub 40} by means of WIEN2K package. Additionally topological analysis of total electron density according to Bader's Quantum Theory of Atoms in Molecules was carried out. The energy band gaps were calculated to be 0.3 eV for Ba{sub 8}Ga{sub 16}Ge{sub 30} and 0.38 eV for Ba{sub 8}Ga{sub 6}Ge{sub 40} which was close to the experimental results for Ba{sub 8}Ga{sub 16}Ge{sub 30}. The observed electrical properties were compared with the electronic band structure calculations, showing good qualitative correlation between the measured transport properties and the theoretical predictions. - Graphical abstract: Scanning thermoelectric microprobe STMP was used to investigate uniformity of the prepared polycrystalline Ba{sub 8}Ga{sub 15}Ge{sub 31} clathrate samples at different synthesis stages. Maps and histograms of the Seebeck coefficient distribution (presented in the picture) for Ba{sub 8}Ga{sub 15}Ge{sub 31} ingot after the first synthesis stage showed it is not uniform. The Seebeck coefficient distribution in the ingot was bimodal. The same analysis for the sample after annealing and sintering showed that the Seebeck coefficient distribution is unimodal. Compared to the ingot from I synthesis stage a significant improvement of material uniformity was observed. Highlights: Black-Right-Pointing-Pointer Scanning thermoelectric microprobe STMP measurements show important uniformity change during sample annealing. Black-Right-Pointing-Pointer Calculated band gap E{sub g} values are close to the reported E{sub g}. Black-Right-Pointing-Pointer Ga/Ge ratio change doesn't affect significantly the bonding properties. Black-Right-Pointing-Pointer Band structure calculations show that bond's character agrees with the Zintl concept.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Abnormal grain growth in AISI 304L stainless steel

The microstructural evolution during abnormal grain growth (secondary recrystallization) in 304L stainless steel was studied in a wide range of annealing temperatures and times. At relatively low temperatures, the grain growth mode was identified as normal. However, at homologous temperatures between 0.65 (850 °C) and 0.7 (900 °C), the observed transition in grain growth mode from normal to abnormal, which was also evident from the bimodality in grain size distribution histograms, was detected to be caused by the dissolution/coarsening of carbides. The microstructural features such as dispersed carbides were characterized by optical metallography, X-ray diffraction, scanning electron microscopy, energy dispersive X-ray analysis, and microhardness. Continued annealing to a long time led to the completion of secondary recrystallization and the subsequent reappearance of normal growth mode. Another instance of abnormal grain growth was observed at homologous temperatures higher than 0.8, which may be attributed to the grain boundary faceting/defaceting phenomenon. It was also found that when the size of abnormal grains reached a critical value, their size will not change too much and the grain growth behavior becomes practically stagnant. - Highlights: • Abnormal grain growth (secondary recrystallization) in AISI 304L stainless steel • Exaggerated grain growth due to dissolution/coarsening of carbides • The enrichment of carbide particles by titanium • Abnormal grain growth due to grain boundary faceting at very high temperatures • The stagnancy of abnormal grain growth by annealing beyond a critical time.

36 MATERIALS SCIENCE↗

Microstructural evolution and grain growth kinetics of GZ31 magnesium alloy

Grain growth behavior of Mg–3Gd–1Zn (GZ31) magnesium alloy was studied in a wide range of annealing time and temperature to clarify the kinetics of grain growth, microstructural evolution and related metallurgical phenomena. This material exhibited typical normal grain growth mode under annealing conditions with annealing temperature of lower than 300 °C and soaking time of lower than 240 min. However, the abnormality in grain growth was also evident at annealing temperature of 400 °C and 500 °C. The dependence of abnormal grain growth (AGG) at mentioned annealing temperatures upon microstructural features such as dispersed precipitates, which were rich in Zn and Gd, was investigated by optical micrographs, X-ray diffraction patterns, scanning electron microscopy images, and energy dispersive X-ray analysis spectra. The bimodality in grain-size distribution histograms also signified the occurrence of AGG. Based on the experimental data on grain growth obtained by annealing treatments, the grain growth exponent and the activation energy were also figured out.

36 MATERIALS SCIENCE↗

Gaussian kernel density functions for compositional quantification in atom probe tomography

Highlights: • A methodology for compositional quantification from atom probe tomography is proposed. • A probability density function p(x) given discrete data points is constructed. • Each atom approximated by a Gaussian function with a particular smoothing parameter. • Density Kernel functions are used to find the optimum smoothing parameter. • The method is validated by using simulated data of semiconductor materials. - Abstract: Atom probe tomography (APT) has the ability to identify the nature and position of single atoms in a material with an almost 3D atomic resolution. However, the quantification of the material composition requires an appropriate treatment of the discrete APT data. When the amount of atoms selected to quantify the composition is relatively small, the spatial resolution is enhanced but the statistical error worsens. Conversely, the increase in the number of atoms considered reduces the spatial resolution, but improving the statistics. We have developed a methodology to reach an optimum equilibrium between the positional and the statistical error in an unsupervised form using Gaussian Kernel density functions. The validity of the method has been tested using APT simulated data of semiconductor materials. It has been proved that the chemical quantification in these materials requires the appropriate selection of the smoothing parameter, obtained without user intervention. In addition, the results have been compared to the usual techniques for composition measurement from APT data (voxelization and proximity histograms), showing better precision for high spatial resolution. This work supplies a data driven methodology based in Gaussian Kernel density functions for the accurate quantification of the composition from APT data.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Impacts of Multileaf Collimators Leaf Width on Intensity-Modulated Radiotherapy Planning for Nasopharyngeal Carcinoma: Analysis of Two Commercial Elekta Devices

We compared the impacts of multileaf collimator (MLC) widths (standard MLC width of 10 mm [SMLC] and micro-MLC width of 4 mm [MMLC]) on intensity-modulated radiotherapy (IMRT) planning for nasopharyngeal carcinoma (NPC). Ten patients with NPC were recruited in this study. In each patient's case, plans were generated with the same machine setup parameter and optimizing methods in a treatment planning system according to 2 commercial Elekta MLC devices. All of the parameters were collected from dose-volume histograms of paired plans and evaluated. The average conformity index (CI) and homogeneous index (HI) for the planning gross target volume in IMRT plans with MMLC were 0.790 {+-} 0.036 and 1.062 {+-} 0.011, respectively. Data in plans with SMLC were 0.754 {+-} 0.038 and 1.070 {+-} 0.010, respectively. The differences were statistically significant (p < 0.05). Compared with CI and HI for planning target volume in paired plans, data with MMLC obviously were better than those with SMLC (CI: 0.858 {+-} 0.026 vs. 0.850 {+-} 0.021, p < 0.05; and HI: 1.185 {+-} 0.011 vs. 1.195 {+-} 0.011, p < 0.05). However, there was no statistical significance between evaluated parameters (Dmean, Dmax, D{sub 5}, gEUD, or NTCP) for organs at risk (OARs) in the 2 paired IMRT plans. According to these two kinds of Elekta MLC devices, IMRT plans with the MMLC have significant advantages in dose coverage for the targets, with more efficiency in treatment for NPC but fail to improve dose sparing of the OARs.

61 RADIATION PROTECTION AND DOSIMETRY↗

Tissue Heterogeneity in IMRT Dose Calculation for Lung Cancer

The aim of this study was to evaluate the differences in accuracy of dose calculation between 3 commonly used algorithms, the Pencil Beam algorithm (PB), the Anisotropic Analytical Algorithm (AAA), and the Collapsed Cone Convolution Superposition (CCCS) for intensity-modulated radiation therapy (IMRT). The 2D dose distributions obtained with the 3 algorithms were compared on each CT slice pixel by pixel, using the MATLAB code (The MathWorks, Natick, MA) and the agreement was assessed with the {gamma} function. The effect of the differences on dose-volume histograms (DVHs), tumor control, and normal tissue complication probability (TCP and NTCP) were also evaluated, and its significance was quantified by using a nonparametric test. In general PB generates regions of over-dosage both in the lung and in the tumor area. These differences are not always in DVH of the lung, although the Wilcoxon test indicated significant differences in 2 of 4 patients. Disagreement in the lung region was also found when the {Gamma} analysis was performed. The effect on TCP is less important than for NTCP because of the slope of the curve at the level of the dose of interest. The effect of dose calculation inaccuracy is patient-dependent and strongly related to beam geometry and to the localization of the tumor. When multiple intensity-modulated beams are used, the effect of the presence of the heterogeneity on dose distribution may not always be easily predictable.

61 RADIATION PROTECTION AND DOSIMETRY↗

Comparison of Prostate IMRT and VMAT Biologically Optimised Treatment Plans

Recently, a new radiotherapy delivery technique has become clinically available-volumetric modulated arc therapy (VMAT). VMAT is the delivery of IMRT while the gantry is in motion using dynamic leaf motion. The perceived benefit of VMAT over IMRT is a reduction in delivery time. In this study, VMAT was compared directly with IMRT for a series of prostate cases. For 10 patients, a biologically optimized seven-field IMRT plan was compared with a biologically optimized VMAT plan using the same planning objectives. The Pinnacle RTPS was used. The resultant target and organ-at-risk dose-volume histograms (DVHs) were compared. The normal tissue complication probability (NTCP) for the IMRT and VMAT plans was calculated for 3 model parameter sets. The delivery efficiency and time for the IMRT and VMAT plans was compared. The VMAT plans resulted in a statistically significant reduction in the rectal V25Gy parameter of 8.2% on average over the IMRT plans. For one of the NTCP parameter sets, the VMAT plans had a statistically significant lower rectal NTCP. These reductions in rectal dose were achieved using 18.6% fewer monitor units and a delivery time reduction of up to 69%. VMAT plans resulted in reductions in rectal doses for all 10 patients in the study. This was achieved with significant reductions in delivery time and monitor units. Given the target coverage was equivalent, the VMAT plans were superior.

61 RADIATION PROTECTION AND DOSIMETRY↗

Dosimetric Comparison of Manual and Beam Angle Optimization of Gantry Angles in IMRT

Dosimetric comparison of manual beam angle selection (MBS) and beam angle optimization (BAO) for IMRT plans is investigated retrospectively for 15 head and neck and prostate patients. The head and neck and prostate had planning target volumes (PTVs) ranging between 96.0 and 319.9 cm{sup 3} and 153.6 and 321.3 cm{sup 3}, whereas OAR ranged between 8.3 and 47.8 cm{sup 3} and 68.3 and 469.2 cm{sup 3}, respectively. In MBS, a standard coplanar 7-9 fields equally spaced gantry angles were used. In BAO, the selection of gantry angle was optimized by the algorithm for the same number of beams. The optimization and dose-volume constraints were kept the same for both techniques. Treatment planning was performed on the Eclipse treatment planning system. Our results showed that the dose-volume histogram for PTV are nearly identical in both techniques but BAO provided superior sparing of the organs at risk compared with the MBS. Also, MBS produced statistically significant higher monitor units (MU) and segments than the BAO; 13.1 {+-} 6.6% (p = 0.012) and 10.4 {+-} 13.6% (p = 0.140), and 14.6 {+-} 5.6% (p = 1.003E-5) and 12.6 {+-} 7.4% (p = 0.76E-3) for head and neck and prostate cases, respectively. The reduction in MU translates into the reduction in total body and integral dose. It is concluded that BAO provides advantage over MBS for most intenisty-modulated radiation therapy cases.

61 RADIATION PROTECTION AND DOSIMETRY↗

Experimental validation of heterogeneity-corrected dose-volume prescription on respiratory-averaged CT images in stereotactic body radiotherapy for moving tumors

The purpose of this study was to experimentally assess the validity of heterogeneity-corrected dose-volume prescription on respiratory-averaged computed tomography (RACT) images in stereotactic body radiotherapy (SBRT) for moving tumors. Four-dimensional computed tomography (CT) data were acquired while a dynamic anthropomorphic thorax phantom with a solitary target moved. Motion pattern was based on cos (t) with a constant respiration period of 4.0 sec along the longitudinal axis of the CT couch. The extent of motion (A{sub 1}) was set in the range of 0.0-12.0 mm at 3.0-mm intervals. Treatment planning with the heterogeneity-corrected dose-volume prescription was designed on RACT images. A new commercially available Monte Carlo algorithm of well-commissioned 6-MV photon beam was used for dose calculation. Dosimetric effects of intrafractional tumor motion were then investigated experimentally under the same conditions as 4D CT simulation using the dynamic anthropomorphic thorax phantom, films, and an ionization chamber. The passing rate of {gamma} index was 98.18%, with the criteria of 3 mm/3%. The dose error between the planned and the measured isocenter dose in moving condition was within {+-} 0.7%. From the dose area histograms on the film, the mean {+-} standard deviation of the dose covering 100% of the cross section of the target was 102.32 {+-} 1.20% (range, 100.59-103.49%). By contrast, the irradiated areas receiving more than 95% dose for A{sub 1} = 12 mm were 1.46 and 1.33 times larger than those for A{sub 1} = 0 mm in the coronal and sagittal planes, respectively. This phantom study demonstrated that the cross section of the target received 100% dose under moving conditions in both the coronal and sagittal planes, suggesting that the heterogeneity-corrected dose-volume prescription on RACT images is acceptable in SBRT for moving tumors.

61 RADIATION PROTECTION AND DOSIMETRY↗

Volumetric modulated arc radiotherapy for esophageal cancer

A treatment planning study was performed to evaluate the performance of volumetric arc modulation with RapidArc (RA) against 3D conformal radiation therapy (3D-CRT) and conventional intensity-modulated radiation therapy (IMRT) techniques for esophageal cancer. Computed tomgraphy scans of 10 patients were included in the study. 3D-CRT, 4-field IMRT, and single-arc and double-arc RA plans were generated with the aim to spare organs at risk (OAR) and healthy tissue while enforcing highly conformal target coverage. The planning objective was to deliver 54 Gy to the planning target volume (PTV) in 30 fractions. Plans were evaluated based on target conformity and dose-volume histograms of organs at risk (lung, spinal cord, and heart). The monitor unit (MU) and treatment delivery time were also evaluated to measure the treatment efficiency. The IMRT plan improves target conformity and spares OAR when compared with 3D-CRT. Target conformity improved with RA plans compared with IMRT. The mean lung dose was similar in all techniques. However, RA plans showed a reduction in the volume of the lung irradiated at V{sub 20Gy} and V{sub 30Gy} dose levels (range, 4.62-17.98%) compared with IMRT plans. The mean dose and D{sub 35%} of heart for the RA plans were better than the IMRT by 0.5-5.8%. Mean V{sub 10Gy} and integral dose to healthy tissue were almost similar in all techniques. But RA plans resulted in a reduced low-level dose bath (15-20 Gy) in the range of 14-16% compared with IMRT plans. The average MU needed to deliver the prescribed dose by RA technique was reduced by 20-25% compared with IMRT technique. The preliminary study on RA for esophageal cancers showed improvements in sparing OAR and healthy tissue with reduced beam-on time, whereas only double-arc RA offered improved target coverage compared with IMRT and 3D-CRT plans.

61 RADIATION PROTECTION AND DOSIMETRY↗