Search NASA⌕ Search

SEARCH · Search NASA

Results for “IMPLANTATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

Carrier recombination parameters in diamond after surface boron implantation and annealing

In this study, an optical pump–probe technique was used to detect spatial distribution of carrier lifetimes across the thickness of a high-quality diamond device structure. Two samples with as-received and boron implanted surfaces were compared to assess the role of implantation and related processing on carrier recombination mechanisms. It was found that the two implanted surfaces show very different behaviors despite undergoing the same treatment. At one of the surfaces, carrier lifetimes remained relatively unchanged, indicating surface recombination rates in the 102–103 cm/s range. At the other surface, carrier lifetimes were almost a magnitude lower and correlated with the locally detected nitrogen vacancy defect that was attributed to the elevated concentration of residual nitrogen.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Defect-mediated diffusion of implanted Mg in GaN: Suppressing dopant redistribution by sequential thermal and microwave annealing

The diffusion behavior of Mg in Mg/N co-implanted GaN is investigated in response to a set of annealing conditions and methodologies, namely, 1000 °C/30 min thermal anneal, by high-temperature pulsed gyrotron microwave annealing at 1420 or 1500 °C, or by thermal and microwave annealing, sequentially. After 1000 °C annealing, the diffusion of Mg in GaN is found to be negligible, as measured by secondary ion mass spectrometry. Annealing by gyrotron microwave annealing alone induces the diffusion of Mg at a rate on the order of 10 −12 cm 2 /s. However, the use of a thermal anneal before microwave gyrotron annealing reduces this rate by an order of magnitude to 10 −13 cm 2 /s. We find that a model that considers Mg diffusion from an inhomogeneous medium that contains a defect-rich implanted region near-surface to a relatively pristine region below the implant range better explains the observed diffusion behavior than a conventional model that assumes a homogeneous medium. By analyzing the diffusion behavior using the Boltzmann–Matano method, we present a discussion of reduction in [V Ga ] by thermal annealing at 1000 °C, leading to a suppressed diffusion coefficient during subsequent high-temperature annealing relative to diffusion after 1420/1500 °C annealing alone. This effect holds potential for improvement in the precision of selectively doped regions for future applications based on the (Al)GaN material system. An improved field profile control in real devices can increase the breakdown and current-handling capabilities in power electronic applications.

Meyers, V.↗

Modulating above-room-temperature magnetism in Ga-implanted Fe 5 GeTe 2 van der Waals magnets

The creation of van der Waals (vdW) ferromagnets with tunable Curie temperature (T C ) and magnetic anisotropy is essential in developing vdW magnet-based devices. Here, we report an effective and reliable method for modulating the magnetic properties of vdW Fe 5 GeTe 2 by site-specific Ga + implantation. In this study, we report an easy axis in the ab-plane for bulk Fe 5 GeTe 2 (T C = 310 K) and an axis out of the plane for thin Fe 5 GeTe 2 flakes (T C = 290 K). Combining element-resolved photoemission electron microscopy and spatially resolved magneto-optic Kerr microscopy, we find that the implantation of a tiny amount of 10 –3 Ga + ·Å –3 in Fe 5 GeTe 2 greatly enhances the T C from 290 to 360 K and switches the magnetic easy axis from the out-of-plane c axis to the ab-plane. The room-temperature x-ray magnetic circular dichroism signal is enhanced from 0% to 9% at an implantation level of 10 –2 Ga + ·Å –3 . These results provide new opportunities for tailoring the magnetic properties of vdW materials beyond room temperature.

36 MATERIALS SCIENCE↗

Comparison of Mg-based liquid metal ion sources for scalable focused-ion-implantation doping of GaN

We compare the suitability of various magnesium-based liquid metal alloy ion sources (LMAISs) for scalable focused-ion-beam (FIB) implantation doping of GaN. We consider GaMg, MgSO 4 $\bullet$7H 2 O, MgZn, AlMg, and AuMgSi alloys. Although issues of oxidation (GaMg), decomposition (MgSO 4 $\bullet$7H 2 O), and excessive vapor pressure (MgZn and AlMg) were encountered, the AuMgSi alloy LMAIS operating in a Wien-filtered FIB column emits all Mg isotopes in singly and doubly charged ionization states. We discuss the operating conditions to achieve <20 nm spot size Mg FIB implantation and present Mg depth profile data from time-of-flight secondary ion mass spectrometry. We also provide insight into implantation damage and recovery based on cathodoluminescence spectroscopy before and after rapid thermal processing. Prospects for incorporating the Mg LMAIS into high-power electronic device fabrication are also discussed.

36 MATERIALS SCIENCE↗

SOLAR WIND IMPLANTATION MODEL FOR {sup 10}Be IN CALCIUM-ALUMINUM INCLUSIONS

We propose a model for the incorporation of {sup 10}Be within calcium-aluminum inclusions (CAIs) in primitive carbonaceous meteorites. In this model, {sup 10}Be is produced by energetic particle reactions in the proto-solar atmosphere of a more active proto-Sun characterized by energetic particle fluxes higher than contemporary particle fluxes. This {sup 10}Be is incorporated into the solar wind that is then implanted into CAI precursor material. This production mechanism is operational in the contemporary solar system implanting {sup 10}Be in lunar materials. The contemporary production rate of {sup 10}Be at the surface of the Sun is {approx}0.1 {sup 10}Be cm{sup -2} s{sup -1}. Scaling up the contemporary {sup 10}Be production in the proto-Sun by a factor of 10{sup 5} would increase the production rate to 10{sup 410}Be cm{sup -2} s{sup -1}. Using this enhanced production value in conjunction with refractory mass inflow rates at 0.06 AU from the proto-Sun we model {sup 10}Be concentrations in CAI precursors. We calculate the content of solar-wind-implanted {sup 10}Be would have been of the order of 10{sup 1210}Be g{sup -1} in CAIs, consistent with initial{sup 10}Be content found from boron-beryllium isotopic systematics in CAIs.

79 ASTRONOMY AND ASTROPHYSICS↗

The Efficacy and Safety of an Intra-articular Dual-Acting Antibacterial Agent (TNP-2092) for Implant Infection–Associated Methicillin-Resistant Staphylococcus aureus

Abstract Owing to the presence of microbial biofilm on the implant, the eradication of biofilm-associated infections poses a challenge for antibiotic therapies. The study aimed to investigate the efficacy and safety of the novel antibiotic agent TNP-2092 in the context of implant infections. In vivo, rats with periprosthetic joint infection (PJI) treated with antibiotics showed an increase in body weight and decrease in swelling, temperature, and width of knee, compared with the control group. Meanwhile, inflammatory markers in synovium and serum were decreased in the TNP-2092 group, consistent with the pathological results. Moreover, TNP-2092 was effective in eliminating bacteria and disruption biofilm formation, and further alleviated the abnormal bone absorption and reactive bone changes around the prosthesis. In conclusion, intra-articular injection of TNP-2092 is safe and effective in treating knee PJI in a rat model. The study provides a foundation for the future utilization of TNP-2092 in the management of implant-related infections.

Dai, Tianyu↗

Evaluation of the accuracy of stopping and range of ions in matter simulations through secondary ion mass spectrometry and Rutherford backscattering spectrometry for low energy heavy ion implantation

The freely available “Stopping and Range of Ions in Matter” (SRIM) code is used for evaluating ion beam ranges and depth profiles. We present secondary ion mass spectrometry and Rutherford backscattering experimental results of Si samples implanted with low energy Sb ions to evaluate the accuracy of SRIM simulations. We show that the SRIM simulation systematically overestimates the range by 2–6 nm and this overestimation increases for larger ion implantation energy. For the lowest energy implantation investigated, here we find up to a 25% error between the SRIM simulation and the measured range. Finally, the ion straggle shows excellent agreement between simulation and experimental results.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Investigation of an implantable dosimeter for single-point water equivalent path length verification in proton therapy

Purpose: In vivo range verification in proton therapy is highly desirable. A recent study suggested that it was feasible to use point dose measurement for in vivo beam range verification in proton therapy, provided that the spread-out Bragg peak dose distribution is delivered in a different and rather unconventional manner. In this work, the authors investigate the possibility of using a commercial implantable dosimeter with wireless reading for this particular application. Methods: The traditional proton treatment technique delivers all the Bragg peaks required for a SOBP field in a single sequence, producing a constant dose plateau across the target volume. As a result, a point dose measurement anywhere in the target volume will produce the same value, thus providing no information regarding the water equivalent path length to the point of measurement. However, the same constant dose distribution can be achieved by splitting the field into a complementary pair of subfields, producing two oppositely ''sloped'' depth-dose distributions, respectively. The ratio between the two distributions can be a sensitive function of depth and measuring this ratio at a point inside the target volume can provide the water equivalent path length to the dosimeter location. Two types of field splits were used in the experiment, one achieved by the technique of beam current modulation and the other by manipulating the location and width of the beam pulse relative to the range modulator track. Eight MOSFET-based implantable dosimeters at four different depths in a water tank were used to measure the dose ratios for these field pairs. A method was developed to correct the effect of the well-known LET dependence of the MOSFET detectors on the depth-dose distributions using the columnar recombination model. The LET-corrected dose ratios were used to derive the water equivalent path lengths to the dosimeter locations to be compared to physical measurements. Results: The implantable dosimeters measured the dose ratios with a reasonable relative uncertainty of 1%-3% at all depths, except when the ratio itself becomes very small. In total, 55% of the individual measurements reproduced the water equivalent path lengths to the dosimeters within 1 mm. For three dosimeters, the difference was consistently less than 1 mm. Half of the standard deviations over the repeated measurements were equal or less than 1 mm. Conclusions: With a single fitting parameter, the LET-correction method worked remarkably well for the MOSFET detectors. The overall results were very encouraging for a potential method of in vivo beam range verification with millimeter accuracy. This is sufficient accuracy to expand range of clinical applications in which the authors could use the distal fall off of the proton depth dose for tight margins.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A novel curvilinear approach for prostate seed implantation

Purpose: A new technique called ''curvilinear approach'' for prostate seed implantation has been proposed. The purpose of this study is to evaluate the dosimetric benefit of curvilinear distribution of seeds for low-dose-rate (LDR) prostate brachytherapy. Methods: Twenty LDR prostate brachytherapy cases planned intraoperatively with VariSeed planning system and I-125 seeds were randomly selected as reference rectilinear cases. All the cases were replanned by using curved-needle approach keeping the same individual source strength and the volume receiving 100% of prescribed dose 145 Gy (V{sub 100}). Parameters such as number of needles, seeds, and the dose coverage of the prostate (D{sub 90}, V{sub 150}, V{sub 200}), urethra (D{sub 30}, D{sub 10}) and rectum (D{sub 5}, V{sub 100}) were compared for the rectilinear and the curvilinear methods. Statistical significance was assessed using two-tailed student's t-test. Results: Reduction of the required number of needles and seeds in curvilinear method were 30.5% (p < 0.001) and 11.8% (p < 0.49), respectively. Dose to the urethra was reduced significantly; D{sub 30} reduced by 10.1% (p < 0.01) and D{sub 10} reduced by 9.9% (p < 0.02). Reduction in rectum dose D{sub 5} was 18.5% (p < 0.03) and V{sub 100} was also reduced from 0.93 cc in rectilinear to 0.21 cc in curvilinear (p < 0.001). Also the V{sub 150} and V{sub 200} coverage of prostate reduced by 18.8% (p < 0.01) and 33.9% (p < 0.001), respectively. Conclusions: Significant improvement in the relevant dosimetric parameters was observed in curvilinear needle approach. Prostate dose homogeneity (V{sub 150}, V{sub 200}) improved while urethral dose was reduced, which might potentially result in better treatment outcome. Reduction in rectal dose could potentially reduce rectal toxicity and complications. Reduction in number of needles would minimize edema and thereby could improve postimplant urinary incontinence. This study indicates that the curvilinear implantation approach is dosimetrically superior to conventional rectilinear implantation technique.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Moving metal artifact reduction in cone-beam CT scans with implanted cylindrical gold markers

Purpose: Implanted gold markers for image-guided radiotherapy lead to streaking artifacts in cone-beam CT (CBCT) scans. Several methods for metal artifact reduction (MAR) have been published, but they all fail in scans with large motion. Here the authors propose and investigate a method for automatic moving metal artifact reduction (MMAR) in CBCT scans with cylindrical gold markers. Methods: The MMAR CBCT reconstruction method has six steps. (1) Automatic segmentation of the cylindrical markers in the CBCT projections. (2) Removal of each marker in the projections by replacing the pixels within a masked area with interpolated values. (3) Reconstruction of a marker-free CBCT volume from the manipulated CBCT projections. (4) Reconstruction of a standard CBCT volume with metal artifacts from the original CBCT projections. (5) Estimation of the three-dimensional (3D) trajectory during CBCT acquisition for each marker based on the segmentation in Step 1, and identification of the smallest ellipsoidal volume that encompasses 95% of the visited 3D positions. (6) Generation of the final MMAR CBCT reconstruction from the marker-free CBCT volume of Step 3 by replacing the voxels in the 95% ellipsoid with the corresponding voxels of the standard CBCT volume of Step 4. The MMAR reconstruction was performed retrospectively using a half-fan CBCT scan for 29 consecutive stereotactic body radiation therapy patients with 2–3 gold markers implanted in the liver. The metal artifacts of the MMAR reconstructions were scored and compared with a standard MAR reconstruction by counting the streaks and by calculating the standard deviation of the Hounsfield units in a region around each marker. Results: The markers were found with the same autosegmentation settings in 27 CBCT scans, while two scans needed slightly changed settings to find all markers automatically in Step 1 of the MMAR method. MMAR resulted in 15 scans with no streaking artifacts, 11 scans with 1–4 streaks, and 3 scans with severe streaking artifacts. The corresponding numbers for MAR were 8 (no streaks), 1 (1–4 streaks), and 20 (severe streaking artifacts). The MMAR method was superior to MAR in scans with more than 8 mm 3D marker motion and comparable to MAR for scans with less than 8 mm motion. In addition, the MMAR method was tested on a 4D CBCT reconstruction for which it worked equally well as for the 3D case. The markers in the 4D case had very low motion blur. Conclusions: An automatic method for MMAR in CBCT scans was proposed and shown to effectively remove almost all streaking artifacts in a large set of clinical CBCT scans with implanted gold markers in the liver. Residual streaking artifacts observed in three CBCT scans may be removed with better marker segmentation.

60 APPLIED LIFE SCIENCES↗

WE-AB-BRA-03: Non-Invasive Controlled Release from Implantable Hydrogel Scaffolds Using Ultrasound

Purpose: To control release of a model payload in acoustically responsive scaffolds (ARSs) using focused ultrasound (FUS). Methods: Fluorescently-labeled dextran (10 kDa) was encapsulated in sonosensitive perfluorocarbon (C{sub 6}F{sub 14} or C{sub 5}F{sub 12}) double emulsions (mean diameter: 2.9±0.1 µm). For in vitro release studies, 0.5 mL ARSs (10 mg/mL fibrin, 1% (v/v) emulsion) were polymerized in 24 well plates and covered with 0.5 mL medium. Starting one day after polymerization, ARSs were exposed to FUS (2.5 MHz, Pr = 8 MPa, 13 cycles, 100 Hz PRF) for 2 min daily. The amount of dextran released into the media was quantified. For in vivo studies, 0.25 mL ARSs were prepared as described previously and injected subcutaneously in the lower back of BALB/c mice. After polymerization, a subset of the implanted ARSs were exposed to FUS (as previously described). Animals were imaged longitudinally using a fluorescence imaging system to quantify the amount of dextran released from the ARSs. Results: In vitro: Over 6 days, +FUS displayed an 8.2-fold increase in dextran release compared to −FUS (−FUS: 2.7±0.6%; +FUS: 22.2±3.0%) for C{sub 6}F{sub 14} ARSs, and a 6.7-fold increase (−FUS: 5.0±0.8%; +FUS: 38.5±1.6%) for C{sub 5}F{sub 12}:C{sub 6}F{sub 14} ARSs. In vivo: +FUS displayed statistically greater dextran release compared to −FUS one day after implantation for C{sub 5}F{sub 12}:C{sub 6}F{sub 14} ARSs (−FUS: 55.1±1.5%; +FUS: 74.1±2.2%) and three days after implantation for C{sub 6}F{sub 14} ARSs (−FUS: 1.4±6.5%; +FUS: 30.4±5.4%). Conclusion: FUS enables non-invasive control of payload release from an ARS, which could benefit growth factor delivery for tissue regeneration. ARS are versatile due to their tunability (i.e. stiffness, emulsion composition, FUS pressure, FUS frequency, etc.) and can be modified to for optimal payload release. Future work will optimize ARS formulations for in vivo use to minimize payload release in the absence of FUS. This work was supported by NIH Grant R21 AR065010 (M.L. Fabiilli) and the Basic Radiologic Sciences Innovative Research Award (M.L. Fabiilli). A. Moncion is supported by the National Science Foundation Graduate Student Research Fellowship (Grant DGE 1256260).

60 APPLIED LIFE SCIENCES↗

On the state of Mn impurity implanted in Si

The state of manganese impurity in implanted silicon at implantation doses of up to 5 x 10{sup 16} cm{sup -2} has been investigated by X-ray diffraction and transmission electron microscopy. It is established that, after short-term vacuum annealing at 850{sup o}C, most of the implanted manganese impurities are in microinclusions up to 20 nm in size formed by a tetragonal silicide phase of the Mn{sub 15}Si{sub 26} type.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Precipitation of boron in silicon on high-dose implantation

Precipitation of boron implanted in silicon with a dose of 1 x 10{sup 16} cm{sup -2} is studied in relation to the concentration of substitutional boron C{sub B{sub 0}} introduced before implantation and before subsequent annealing at 900 deg. C. It is shown that C{sub B{sub 0}} = 2.5 x 10{sup 20} cm{sup -3} is the critical concentration, at which the formation of precipitates is independent of the concentration of point defects introduced by implantation (far from or close to the mean projected range R{sub p}) and constitutes the prevailing channel of deactivation of boron. At lower concentrations C{sub B{sub 0}} close to the equilibrium concentration, precipitation is observed only far from R{sub p}, in the regions of reduced concentrations of point defects. At the same time, in the region of R{sub p} with a high concentration of point defects, most boron atoms are drawn into clustering with intrinsic interstitial atoms with the formation of dislocation loops and, thus, become electrically inactive as well.

36 MATERIALS SCIENCE↗

Optical properties of oxygen-implanted CdS:O layers in terms of band anticrossing theory

The microcathodoluminescence (MCL) and photoreflection spectra of CdS:O layers implanted with oxygen ions to 4 Multiplication-Sign 10{sup 20} cm{sup -3} are investigated. Used method of MCL spectroscopy yields information only about the implanted-layer volume. Exciton MCL spectra, which allow one to determine the concentration of dissolved oxygen in the CdS:O layers and the influence of deviation of the substrates from stoichiometry, are recorded. The homogeneity of the ion-implanted layers is studied by cathodoluminescence (CL) scanning electron microscopy. The relationship between light-emitting areas and the luminescence band at {approx}630 nm is established. The reason for enhancement of this band upon radiation annealing is revealed and its nature as the luminescence of F{sup +} centers in CdS is confirmed. New photoreflection spectroscopy data are obtained, which describe the specific behavioral features of oxygen on the layer surface as an isoelectronic impurity in highly mismatched alloys (HMAs). It is shown that sulfur completely bonds and removes oxygen from CdS:O. Oxygen-free CdS remains on the surface in the form of nanoparticles, the size of which depends on the oxygen concentration in the CdS:O layer bulk. The results obtained are in agreement with the predictions of band anticrossing theory.

36 MATERIALS SCIENCE↗

TiO 2 Nanocoatings with Controllable Crystal Type and Nanoscale Topography on Zirconia Implants to Accelerate Bone Formation

In dentistry, zirconia implants have emerged as a promising alternative for replacing missing teeth due to their superior aesthetic performance and chemical stability. To improve the osseointegration of zirconia implants, modifying their surface with hierarchical micro/nanotopography and bioactive chemical composition are two effective ways. In this work, a microscale topography was prepared on a zirconia surface using hydrofluoric acid etching, and then a 50 nm TiO 2 nanocoating was deposited via atomic layer deposition (ALD). Subsequently, an annealing treatment was used to transform the TiO 2 from amorphous to anatase and simultaneously generate nanoscale topography. Various investigations into the coating surface morphology, topography, wettability, and chemical composition were carried out using scanning electron microscopy, white light interferometry, contact‐angle measurement, X‐ray diffraction, and X‐ray photoelectron spectroscopy. In addition, in vitro cytocompatibility and osteogenic potential performance of the coatings were evaluated by human bone marrow mesenchymal stem cells (hBMSCs), and in vivo osseointegration performance was assessed in a rat femoral condyle model. Moreover, the possible mechanism was also investigated. The deposition of TiO 2 film with/without annealing treatment did not alter the microscale roughness of the zirconia surface, whereas the nanotopography changed significantly after annealing. The in vitro studies revealed that the anatase TiO 2 coating with regular wavelike nanostructure could promote the adhesion and proliferation of osteoblasts and further improve the osteogenic potential in vitro and osseointegration in vivo. These positive effects may be caused by nanoscale topography via the canonical Wnt/ β ‐catenin pathway. The results suggest that using ALD in combination with annealing treatment to fabricate a nanotopographic TiO 2 coating is a promising way to improve the osteogenic properties of zirconia implants.

Li, Nan (ORCID:0000000255156737)↗

Oxidation State of 229 Th Recoils Implanted into MgF 2 Crystals

A solid-state nuclear clock based on the low-lying isomeric state in 229 Th has attracted growing interest. One potential problem for the solid-state nuclear clock approach is the suitability of the doped environment for photon emission of the nuclear isomeric state. Specifically, Th n+ n < 4 ions could open non-radiative decay routes for deexcitation, hindering the photon emission. Here we have used time-resolved photoluminescence (TRPL) and density functional theory (DFT) calculations to characterize MgF 2 crystals that have been implanted with 229 Th recoils via a-decay from a 233 U source with the goal of determining the charge state of the implanted thorium atoms. The DFT calculations predicted Th4+ to be the lowest energy oxidation state with Th3+ the next lowest in the MgF2 crystal environment. The DFT calculations also show Th4+:MgF 2 system has a band gap large enough so that the internal electron conversion decay channel is suppressed. Experimentally, we found no evidence for thorium in oxidations state other than +4 using TRPL spectroscopy that has a detection limit for Thn+ n < 4 ions several orders of magnitude smaller than the number of implanted 229Th recoils. This work shows that the solid-state approach is a viable option for a nuclear clock.

229Th Isomeric State↗

Determine the Influence of Time Held in “Knockdown” Anesthesia on Survival and Stress of Surgically Implanted Juvenile Salmonids

The Juvenile Salmon Acoustic Telemetry System (JSATS) was developed for the U.S. Army Corp of Engineers Portland District (USACE) to address questions related to survival and performance measures of juvenile salmonids as they pass through the Federal Columbia River Power System (FCRPS). Researchers using JSATS acoustic transmitters (ATs) were tasked with standardizing the surgical implantation procedure to ensure that the stressors of handling and surgery on salmonids were consistent and less likely to cause effects of tagging in survival studies. Researchers questioned whether the exposure time in 'knockdown' anesthesia (or induction) to prepare fish for surgery could influence the survival of study fish (CBSPSC 2011). Currently, fish are held in knockdown anesthesia after they reach Stage 4 anesthesia until the completion of the surgical implantation of a transmitter, varies from 5 to 15 minutes for studies conducted in the Columbia Basin. The Columbia Basin Surgical Protocol Steering Committee (CBSPSC ) expressed concern that its currently recommended 10-minute maximum time limit during which fish are held in anesthetic - tricaine methanesulfonate (MS-222, 80 mg L-1 water) - could increase behavioral and physiological costs, and/or decrease survival of outmigrating juvenile salmonids. In addition, the variability in the time fish are held at Stage 4 could affect the data intended for direct comparison of fish within or among survival studies. Under the current recommended protocol, if fish exceed the 10-minute time limit, they are to be released without surgical implantation, thereby increasing the number of fish handled and endangered species 'take' at the bypass systems for FCRPS survival studies.

24 POWER TRANSMISSION AND DISTRIBUTION↗

In Situ Electron Microscopy of Helium Bubble Implantation in Metal Hydrides

Here we investigated the microstructural response of various Pd physically vapor deposited films and Er and ErD 2 samples prepared from neutron Tube targets to implanted He via in situ ion irradiation transmission electron microscopy and subsequent in situ annealing experiments. Small bubbles formed in both systems during implantation, but did not grow with increasing fluence or a short duration room temperature aging (weeks). Annealing produced large cavities with different densities in the two systems. The ErD 2 showed increased cavity nucleation compared to Er. The spherical bubbles formed from high fluence implantation and rapid annealing in both Er and ErD 2 cases differed from microstructures of naturally aged tritiated samples. Further work is still underway to determine the transition in bubble shape in the Er samples, as well as the mechanism for evolution in Pd films.

36 MATERIALS SCIENCE↗