Search NASA⌕ Search

SEARCH · Search NASA

Results for “ION SOURCE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

New progress of high current gasdynamic ion source (invited)

The experimental and theoretical research carried out at the Institute of Applied Physics resulted in development of a new type of electron cyclotron resonance ion sources (ECRISs)—the gasdynamic ECRIS. The gasdynamic ECRIS features a confinement mechanism in a magnetic trap that is different from Geller’s ECRIS confinement, i.e., the quasi-gasdynamic one similar to that in fusion mirror traps. Experimental studies of gasdynamic ECRIS were performed at Simple Mirror Ion Source (SMIS) 37 facility. The plasma was created by 37.5 and 75 GHz gyrotron radiation with power up to 100 kW. High frequency microwaves allowed to create and sustain plasma with significant density (up to 8 × 10{sup 13} cm{sup −3}) and to maintain the main advantages of conventional ECRIS such as high ionization degree and low ion energy. Reaching such high plasma density relies on the fact that the critical density grows with the microwave frequency squared. High microwave power provided the average electron energy on a level of 50-300 eV enough for efficient ionization even at neutral gas pressure range of 10{sup −4}–10{sup −3} mbar. Gasdynamic ECRIS has demonstrated a good performance producing high current (100-300 mA) multi-charged ion beams with moderate average charge (Z = 4-5 for argon). Gasdynamic ECRIS has appeared to be especially effective in low emittance hydrogen and deuterium beams formation. Proton beams with current up to 500 emA and RMS emittance below 0.07 π ⋅ mm ⋅ mrad have been demonstrated in recent experiments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The MIST-1 and MIST-2 multicusp ion sources for high-current $H$$^{+}_{2}$ beams

We present two iterations of the Multicusp Ion Source Technology at MIT (MIST) sources, designed to fulfill the requirements of the HCHC-XX cyclotron design. The HCHC-XX is a novel compact cyclotron accelerating $H$$^{+}_{2}$. Beam is injected through a radio-frequency quadrupole buncher-accelerator (embedded in the cyclotron yoke) and utilizes so-called vortex motion during acceleration. If successful, it will deliver 10 mA of protons at 60 MeV in CW mode. This scheme requires a low-emittance, high-current initial beam with high $H$$^{+}_{2}$ purity. We briefly summarize the design and previous results of the MIST-1 ion source and, for the first time, the detailed design of the new and improved MIST-2, including the mechanical, electrical, and control system design. We further show experimental results of using the MIST-2 backplate on the MIST-1 body, present a study using different types of permanent magnets for confinement (including no magnets), and finally, we present first results of the MIST-2 in full operation. In this first commissioning run, we were able to increase the total extracted current from the MIST-2 to 7 mA—a factor of 2 over the MIST-1.

Winklehner, D. [Massachusetts Institute of Technol↗

Production and ion-ion cooling of highly charged ions in electron string ion source

The scheme of an internal injection of Au atoms into the working space of the ''Krion-2'' electron string ion source (ESIS) was applied and tested. In this scheme Au atoms are evaporated from the thin tungsten wire surface in vicinity of the source electron string. Ion beams with charge states up to Au{sup 51+} were produced. Ion-ion cooling with use of C and O coolant ions was studied. It allowed increasing of the Au{sup 51+} ion yield by a factor of 2. Ions of Kr up to charge state 28+ were also produced in the source. Electron strings were first formed with injection electron energy up to 6 keV. Methods to increase the ESIS ion output are discussed.

43 PARTICLE ACCELERATORS↗

Dependence of ion beam current on position of mobile plate tuner in multi-frequencies microwaves electron cyclotron resonance ion source

We are constructing a tandem-type electron cyclotron resonance ion source (ECRIS). The first stage of this can supply 2.45 GHz and 11-13 GHz microwaves to plasma chamber individually and simultaneously. We optimize the beam current I{sub FC} by the mobile plate tuner. The I{sub FC} is affected by the position of the mobile plate tuner in the chamber as like a circular cavity resonator. We aim to clarify the relation between the I{sub FC} and the ion saturation current in the ECRIS against the position of the mobile plate tuner. We obtained the result that the variation of the plasma density contributes largely to the variation of the I{sub FC} when we change the position of the mobile plate tuner.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Angular-divergence calculation for Experimental Advanced Superconducting Tokamak neutral beam injection ion source based on spectroscopic measurements

Calorimetric method has been primarily applied for several experimental campaigns to determine the angular divergence of high-current ion source for the neutral beam injection system on the Experimental Advanced Superconducting Tokamak (EAST). A Doppler shift spectroscopy has been developed to provide the secondary measurement of the angular divergence to improve the divergence measurement accuracy and for real-time and non-perturbing measurement. The modified calculation model based on the W7AS neutral beam injectors is adopted to accommodate the slot-type accelerating grids used in the EAST's ion source. Preliminary spectroscopic experimental results are presented comparable to the calorimetrically determined value of theoretical calculation.

43 PARTICLE ACCELERATORS↗

Overview of H- radio frequency ion sources for particle accelerators

Particle accelerators are among the most important scientific tools of the modern era. Large accelerator complexes have supported scientific user facilities which have had an enormous societal impact spanning many decades and enabling the work of thousands of scientific users worldwide contributing to many Nobel prizes in physics, biology and chemistry [1]. Many of the large hadron facilities employ accelerator complexes which include cyclotrons, synchrotrons, storage rings, linear or tandem accelerators and deliver ion beams of very high-intensity and/or very high-energy to their user facilities. These accelerator complexes require the injection of high-intensity beams of ions which are produced within an ion source and formed within a plasma or by bombardment of a surface [2]. Increasingly, RF systems are being utilized, to generate these ion-rich plasmas due to their high reliability and minimal use of consumable components. This report will first discuss the basic mechanisms of ion formation and plasma generation as well as some specifics of RF/microwave generators, matching circuits and plasma coupling structures typically employed. A detailed discussion will then be given of the RF-driven negative ion source systems employed by US Spallation Neutron Source as well as those used in similar facilities located around the globe. REFERENCES [1]Vladimir Shiltsev, “Particle beams behind physics discoveries”, Physics Today 73, Issue 4, 32 (2020) [2]Robert Welton et al, “Negative hydrogen ion sources for particle accelerators: Sustainability issues and recent improvements in long-term operations”, Journal of Physics Conf Series, 2244 012045

Welton, Robert F.↗

Plasma Structure in the Extraction Region of a Hybrid Negative Ion Source

Production, destruction and transport of negative ions in the extraction region of a hybrid negative ion source are investigated with a one-dimensional Particle-in-Cell electrostatic code. The influence of the plasma grid bias and of the magnetic filter on the plasma parameter profiles is taken into account. In particular, a transition from classical to complete reverse sheath is observed using a positively biased plasma grid, while the effect of the magnetic filter is relatively small proofing that H{sup -} production is dominated by surface neutral conversion.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Alternative uses of a megavolt tandem accelerator for few-keV studies with ion-source SIMS monitoring

We increase the versatility of a tandem electrostatic accelerator by implementing simple modifications to the standard operation procedure. While keeping its ability to deliver MeV ion beams, we show that the experimental setup can (i) provide good quality ion beams in the few-keV energy range and (ii) be used to study ion-beam surface modification with simultaneous secondary ion mass spectrometry. This latter task is accomplished without using any chamber connected to the accelerator exit. We perform mass spectrometry of the few-keV anions produced in the ion source by measuring their neutral counterparts at the accelerator exit with energies up to 1.7 MeV. With an additional modification, a high-current few-keV regime is obtained, using the ion source as an irradiation chamber and the accelerator itself only as a mass spectrometer. As an example of application, we prepare a sample for the study of ion-beam assisted dewetting of a thin Au film on a Si substrate.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design of the new extraction grid for the NIO1 negative ion source

NIO1 is a compact source of negative ions jointly developed by RFX and INFN, to study the physics of production and acceleration of H{sup −} beams. Negative ions, up to 120 mA of current, are extracted from a radiofrequency driven plasma, by means of a gridded electrode (plasma grid, PG) featuring 9 apertures arranged in a 3x3 square lattice. The same aperture pattern is replicated in the following electrodes, allowing ion acceleration up to 60 keV. All electrodes are realized in copper, by electro-deposition technique, leaving empty slots in the metal to place magnets and to flow water for the grid cooling. The first set of electrodes was completed, installed in the source and tested. At the same time, an upgrade of the extraction system was carried out, in order to optimize the beam optics and to explore alternative electrostatic configurations. In particular, the accelerator will be modified by completely replacing the EG grid, exploiting the modularity of NIO1. The new electrode will feature other slots in between apertures, to place additional magnets. This allows testing different magnetic configurations, to optimize electron filtering and residual ion deflection. The present paper describes the theoretical activities driving the design of these new extractors, carried out with most updated numerical codes, and exploiting the synergy with the refined modeling of the 40 A ITER negative ion sources, under development at Consorzio RFX. Beam simulations are performed both with tracing codes (SLACCAD and OPERA) and with particle in cell codes (ACCPIC)

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A compact time-of-flight mass spectrometer for ion source characterization

A compact time-of-flight mass spectrometer with overall dimension of about 413 × 250 × 414 mm based on orthogonal injection and angle reflection has been developed for ion source characterization. Configuration and principle of the time-of-flight mass spectrometer are introduced in this paper. The mass resolution is optimized to be about 1690 (FWHM), and the ion energy detection range is tested to be between about 3 and 163 eV with the help of electron impact ion source. High mass resolution and compact configuration make this spectrometer useful to provide a valuable diagnostic for ion spectra fundamental research and study the mass to charge composition of plasma with wide range of parameters.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design improvements to the SNS ion source and diagnostics

The U.S. Spallation Neutron Source (SNS) is a state-of-the-art neutron scattering facility delivering the world's most intense pulsed-neutron beams to a wide array of instruments which are used to conduct investigations in many fields of science and engineering. The accelerator system is fed by an RF-driven, multicusp, H - ion source which nominally provides pulsed beam currents of 50-60 mA (1ms, 60Hz). This report provides a discussion of ongoing design improvements to the SNS ion source and Low Energy Beam Transport (LEBT) as well as diagnostic upgrades undertaken since the previous ICIS conference. These improvements include (i) simple mechanical modifications to the source outlet aperture which resulted in dramatically increased extracted beam current and comparable or lower emittance at similar beam currents, (ii) design improvements to the LEBT chopper target which will enable full power beam-dumping during physics studies, (iii) refinement of the SNS Allison emittance scanner that has enabled the first reliable LEBT beam measurements at full beam power (65kV, 50-100mA, 1ms, 60Hz) on the SNS ion source test stand and (iv) the implementation of a thermal imaging camera for the monitoring the LEBT electrode temperatures. (v) The design of an advanced Cs system, capable of more efficient Cs utilization with significantly lower Cs losses from the source is also presented. Mechanical details, computational simulations and experimental results are discussed within the context of these improvements.

47 OTHER INSTRUMENTATION↗

Experiment study of an electron cyclotron resonant ion source based on a tapered resonance cavity

Electron cyclotron resonant plasma is one type of magnetised plasma generated by continuous microwave energy. It has the property of high degree of ionization and large volume at low gas pressure, which makes it useful for space propulsion and material processing. This article presents the experiment study of the plasma properties and ion beam extraction from an electron cyclotron resonant ion source based on a tapered resonance cavity. Optical emission spectroscopy based on a simple collisional radiation model was used for plasma diagnosis. Experiment results show that, at microwave power setting ranging from 7.06 to 17.40 W and mass flow rate ranging from 1 to 10 sccm, argon gas can be ionized. Ion beam of 109.1 mA from the ion source can be extracted at microwave power of 30 W, mass flow rate of 10 sccm, and accel voltage of 800 V. The diagnosed plasma temperature and density are 2.4–5.2 eV and 2 × 10{sup 16}–4.8 × 10{sup 17} m{sup −3}, respectively.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Bio-Nano ECRIS: An electron cyclotron resonance ion source for new materials production

We developed an electron cyclotron resonance ion source (ECRIS) for new materials production on nanoscale. Our main target is the endohedral fullerenes, which have potential in medical care, biotechnology, and nanotechnology. In particular, iron-encapsulated fullerene can be applied as a contrast material for magnetic resonance imaging or microwave heat therapy. Thus, our new ECRIS is named the Bio-Nano ECRIS. In this article, the recent progress of the development of the Bio-Nano ECRIS is reported: (i) iron ion beam production using induction heating oven and (ii) optimization of singly charged C{sub 60} ion beam production.

36 MATERIALS SCIENCE↗

Transport and emittance study for 18 GHz superconducting-ECR ion source at RCNP

As the upgrade program of the azimuthally varying field (AVF) cyclotron is at the cyclotron facility of the RCNP, Osaka University for the improvement of the quality, stability, and intensity of accelerated beams, an 18 GHz superconducting (SC) ECR ion source has been installed to increase beam currents and to extend the variety of ions, especially for highly charged heavy ions which can be accelerated by RCNP AVF cyclotron. The production development of several ions such as B, O, N, Ne, Ar, Ni, Kr, and Xe has been performed by Yorita et al.[Rev. Sci. Instrum. 79, 02A311(2008); 81, 02A332 (2010)]. Further studies for the beam transport have been done in order to improve the beam current more for injection of cyclotron. The effect of field leakage of AVF main coil is not negligible and additional steering magnet has been installed and then beam transmission has been improved. The emittance monitor has also been developed for the purpose of investigating correlation between emittance of beam from ECR ion sources and injection efficiency. The monitor consists with BPM82 with rotating wire for fast measurement for efficient study.

43 PARTICLE ACCELERATORS↗

Hydrogen atom temperature measured with wavelength-modulated laser absorption spectroscopy in large scale filament arc negative hydrogen ion source

The velocity distribution function of hydrogen atoms is one of the useful parameters to understand particle dynamics from negative hydrogen production to extraction in a negative hydrogen ion source. Hydrogen atom temperature is one of the indicators of the velocity distribution function. To find a feasibility of hydrogen atom temperature measurement in large scale filament arc negative hydrogen ion source for fusion, a model calculation of wavelength-modulated laser absorption spectroscopy of the hydrogen Balmer alpha line was performed. By utilizing a wide range tunable diode laser, we successfully obtained the hydrogen atom temperature of ∼3000 K in the vicinity of the plasma grid electrode. The hydrogen atom temperature increases as well as the arc power, and becomes constant after decreasing with the filling of hydrogen gas pressure.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Performance of a liquid Ga target for Laser Ion Source

We experimentally proved the feasibility of a liquid-based target for Laser Ion Source (LIS) application. The target consists of melted metal gallium contained in a heated crucible. Ions current resulting from laser irradiation. Moreover, given the explosive ablation mechanism involved, each laser shot has been found to induce fluctuations in the surface level. It takes about 0.7 sec to recover the steady condition fully. Despite the maximum fluctuation being 2.7 mm (top-bottom maximum displacement), these fluctuations have shown no significant influence on total ion current and are independent of the temperature of the sample within the tested repetition rate. This study provides valuable insights into the potential of employing such a system for LIS.

43 PARTICLE ACCELERATORS↗

Simulation of parameter scaling in electron cyclotron resonance ion source plasmas using the GEM code

Although heating power and gas pressure are two of the two of primary experimental ''knobs'' available to users of electron cyclotron resonance ion sources, there is still no clear understanding of how they interact in order to provide optimal plasma conditions. FAR-TECH, Inc. has performed a series of simulations with its generalized electron cyclotron resonance ion source model in which the power and pressure were varied over a wide range. Analysis of the numerical data produces scaling laws that predict the plasma parameters as a function of the power and pressure. These scaling laws are in general agreement with experimental data.

43 PARTICLE ACCELERATORS↗