Search NASA⌕ Search

SEARCH · Search NASA

Results for “Image”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

Science and Science-Enabling Activities of the SHERLOC and WATSON Imaging Systems in Jezero Crater, Mars

During its first year of operation, the Perseverance rover explored the cratered and fractured floor of Jezero crater on Mars. Here, we report the use of the Scanning Habitability Environments with Raman and Luminescence for Organics and Chemicals (SHERLOC) imaging system that includes two high-resolution cameras, the Autofocus and Contextual Imager (ACI) and Wide Angle Topographic Sensor for Operations and eNgineering (WATSON). ACI is a fixed focus gray scale imager with a resolution of 10.1 μm/pixel whereas WATSON is a variable field of view, variable focus imager capable of resolution down to 14 μm/pixel. WATSON is a reflight of the MArs Hand Lens Imager (MAHLI) imager and has similar capabilities. During first-time activities, WATSON was used to support both science and engineering operations related to sample and abrasion patch assessment and sample collection and caching. WATSON also documented the deployment of the Ingenuity helicopter. The Crater Floor Campaign identified two primary rock units, the Máaz formation and the Séítah formation, which have been interpreted as lava flows and an olivine cumulate, respectively. Interpretation of rock textures with WATSON and ACI images was limited to abraded surfaces because unmodified outcrop surfaces (herein termed “natural surfaces”) show high degrees of dust covering, wind abrasion, and coating by secondary mineral products. WATSON and ACI images support the hypothesis that the material of both the Máaz and Séítah formations consists of largely aqueously altered mafic materials with varying igneous origins.

WATSON↗

RGB Imaging as a Tool to Monitor Indoor Crop Plant Production

Future crop production in space will require robust monitoring technologies that can optimize crop yield, reduce waste, and generate data for an automated plant growth design. Imaging has been suggested as a tool for measuring plant health, yet imaging systems for indoor crops have not been tested in spaceflight. Fortunately, RGB images of crop plants growing inside the Advanced Plant Habitat (APH) aboard the ISS have already been captured. In ground-based studies, the Kennedy Space Center (NASA, KSC) is collaborating with the United States Department of Agriculture (USDA ARS) to develop an imaging system for monitoring indoor crop plant health. In one study, we applied a drought stress to ‘Dragoon’ lettuce plants over a period of 14 days and captured RGB images in 24 h increments. Images were analyzed, and by applying a difference index, the images were able to be used to detect the drought stress in lettuce. This difference index was then applied to RGB images collected inside the APH ground unit for a pre-flight experiment growing ‘Outredgous’ lettuce under different substrate moisture conditions, and results showed that the RGB camera was capable of detecting drought stress inside the spaceflight plant growth hardware. These results suggest that RGB cameras already deployed to space may offer valuable information for monitoring plant production in extraterrestrial environments. This research was supported by NASA’s space biology program.

Rachel Tucker↗

Broadband unidirectional visible imaging using wafer-scale nano-fabrication of multi-layer diffractive optical processors

We present a broadband and polarization-insensitive unidirectional imager that operates at the visible part of the spectrum, where image formation occurs in one direction, while in the opposite direction, it is blocked. This approach is enabled by deep learning-driven diffractive optical design with wafer-scale nano-fabrication using high-purity fused silica to ensure optical transparency and thermal stability. Our design achieves unidirectional imaging across three visible wavelengths (covering red, green, and blue parts of the spectrum), and we experimentally validated this broadband unidirectional imager by creating high-fidelity images in the forward direction and generating weak, distorted output patterns in the backward direction, in alignment with our numerical simulations. This work demonstrates wafer-scale production of diffractive optical processors, featuring 16 levels of nanoscale phase features distributed across two axially aligned diffractive layers for visible unidirectional imaging. This approach facilitates mass-scale production of ~0.5 billion nanoscale phase features per wafer, supporting high-throughput manufacturing of hundreds to thousands of multi-layer diffractive processors suitable for large apertures and parallel processing of multiple tasks. Beyond broadband unidirectional imaging in the visible spectrum, this study establishes a pathway for artificial-intelligence-enabled diffractive optics with versatile applications, signaling a new era in optical device functionality with industrial-level, massively scalable fabrication.

36 MATERIALS SCIENCE↗

Three Photon Excited Image Scanning Microscopy for in-Depth Super-Resolution Studies of Biological Samples

Multiphoton laser scanning microscopy is a powerful tool for deep imaging of thick biological samples. Image scanning microscopy (ISM) has demonstrated significant improvements in the signal-to-noise ratio in confocal laser scanning microscopy, while at the same time improving upon the effectively attainable resolution. Two-photon excitation (2PE), combined with ISM, has been shown to allow for deep tissue imaging with enhanced resolution compared to 2PE microscopy. Three-photon excitation (3PE) has enabled record imaging depth and contrast for multiphoton imaging, due to the superior suppression of out-of-focus signal generation. In this paper, we demonstrate super-resolution 3PE ISM. This is achieved using a single-photon avalanche detector array, and 1040-nm pulses for 3PE of blue fluorescence. This method enables subdiffraction limited resolution imaging of biological samples stained with blue fluorescent markers, such as mouse myocardial and spinal cord tissues stained with 4 ′ , 6 -diamidino-2-phenylindole. Deconvolution improves the resolving power further and allows for imaging with better than λ / 8 resolution with respect to the 3PE wavelength λ . With the ISM pixel reassignment procedure, we demonstrate a resolution enhancement of ∼ 1.6 laterally, compared to the resolution attained using a photomultiplier tube in a non-descanned detection arrangement, and a factor of ∼ 1.8 enhancement in axial resolution. The experimentally measured three-dimensional point spread function volume is shrunk ∼ 4.4 -fold, which is close to the theoretically expected enhancement. Published by the American Physical Society 2024

47 OTHER INSTRUMENTATION↗

Integrated photonic encoder for low power and high-speed image processing

Abstract Modern lens designs are capable of resolving greater than 10 gigapixels, while advances in camera frame-rate and hyperspectral imaging have made data acquisition rates of Terapixel/second a real possibility. The main bottlenecks preventing such high data-rate systems are power consumption and data storage. In this work, we show that analog photonic encoders could address this challenge, enabling high-speed image compression using orders-of-magnitude lower power than digital electronics. Our approach relies on a silicon-photonics front-end to compress raw image data, foregoing energy-intensive image conditioning and reducing data storage requirements. The compression scheme uses a passive disordered photonic structure to perform kernel-type random projections of the raw image data with minimal power consumption and low latency. A back-end neural network can then reconstruct the original images with structural similarity exceeding 90%. This scheme has the potential to process data streams exceeding Terapixel/second using less than 100 fJ/pixel, providing a path to ultra-high-resolution data and image acquisition systems.

47 OTHER INSTRUMENTATION↗

Image processing tools for petabyte-scale light sheet microscopy data

Light sheet microscopy is a powerful technique for high-speed three-dimensional imaging of subcellular dynamics and large biological specimens. However, it often generates datasets ranging from hundreds of gigabytes to petabytes in size for a single experiment. Conventional computational tools process such images far slower than the time to acquire them and often fail outright due to memory limitations. To address these challenges, we present PetaKit5D, a scalable software solution for efficient petabyte-scale light sheet image processing. This software incorporates a suite of commonly used processing tools that are optimized for memory and performance. Notable advancements include rapid image readers and writers, fast and memory-efficient geometric transformations, high-performance Richardson–Lucy deconvolution and scalable Zarr-based stitching. These features outperform state-of-the-art methods by over one order of magnitude, enabling the processing of petabyte-scale image data at the full teravoxel rates of modern imaging cameras. The software opens new avenues for biological discoveries through large-scale imaging experiments.

97 MATHEMATICS AND COMPUTING↗

Quantum imaging with positronium-decay-emitted gamma rays

The use of entangled gamma rays from positronium decay for quantum-enhanced imaging of dense materials is demonstrated. Quantum ghost images, where only one of the entangled 511-keV photons interacts with the object, are obtained for tantalum samples of varying density using a 210-ps time-resolution dual detector system and a Na-22 positron source. An analysis comparing both classical and quantum imaging modalities is employed to isolate true 511-keV events from background noise. Image quality is quantitatively assessed using transmission ratios and the Michelson contrast. Quantum-correlated images are found to exhibit superior (up to approximately 1.7x, from 0.49 to 0.83 in the thickest sample measured) contrast compared to classical methods and align well with theoretical expectations. These results suggest that quantum ghost imaging with positronium-based entangled gamma rays could significantly enhance noninvasive imaging of high-density objects, with potential applications in areas such as cargo inspection and security screening.

36 MATERIALS SCIENCE↗

Divide and conquer: using RhizoVision Explorer to aggregate data from multiple root scans using image concatenation and statistical methods

Roots are important in agricultural and natural systems for determining plant productivity and soil carbon inputs. Sometimes, the amount of roots in a sample is too much to fit into a single scanned image, so the sample is divided among several scans, and there is no standard method to aggregate the data. Here, we describe and validate two methods for standardizing measurements across multiple scans: image concatenation and statistical aggregation. We developed a Python script that identifies which images belong to the same sample and returns a single, larger concatenated image. These concatenated images and the original images were processed with RhizoVision Explorer, a free and open-source software. An R script was developed, which identifies rows of data belonging to the same sample and applies correct statistical methods to return a single data row for each sample. These two methods were compared using example images from switchgrass, poplar, and various tree and ericaceous shrub species from a northern peatland and the Arctic. Most root measurements were nearly identical between the two methods except median diameter, which cannot be accurately computed by statistical aggregation. We believe the availability of these methods will be useful to the root biology community.

59 BASIC BIOLOGICAL SCIENCES↗

Is the spatial distribution of brain lesions associated with closed-head injury predictive of subsequent development of attention-deficit/hyperactivity disorder? Analysis with brain-image database

PURPOSE: To determine whether there is an association between the spatial distribution of lesions detected at magnetic resonance (MR) imaging of the brain in children after closed-head injury and the development of secondary attention-deficit/hyperactivity disorder (ADHD). MATERIALS AND METHODS: Data obtained from 76 children without prior history of ADHD were analyzed. MR images were obtained 3 months after closed-head injury. After manual delineation of lesions, images were registered to the Talairach coordinate system. For each subject, registered images and secondary ADHD status were integrated into a brain-image database, which contains depiction (visualization) and statistical analysis software. Using this database, we assessed visually the spatial distributions of lesions and performed statistical analysis of image and clinical variables. RESULTS: Of the 76 children, 15 developed secondary ADHD. Depiction of the data suggested that children who developed secondary ADHD had more lesions in the right putamen than children who did not develop secondary ADHD; this impression was confirmed statistically. After Bonferroni correction, we could not demonstrate significant differences between secondary ADHD status and lesion burdens for the right caudate nucleus or the right globus pallidus. CONCLUSION: Closed-head injury-induced lesions in the right putamen in children are associated with subsequent development of secondary ADHD. Depiction software is useful in guiding statistical analysis of image data.

NASA Discipline Neuroscience↗

A back-illuminated megapixel CMOS image sensor

In this paper, we present the test and characterization results for a back-illuminated megapixel CMOS imager. The imager pixel consists of a standard junction photodiode coupled to a three transistor-per-pixel switched source-follower readout [1]. The imager also consists of integrated timing and control and bias generation circuits, and provides analog output. The analog column-scan circuits were implemented in such a way that the imager could be configured to run in off-chip correlated double-sampling (CDS) mode. The imager was originally designed for normal front-illuminated operation, and was fabricated in a commercially available 0.5 pn triple-metal CMOS-imager compatible process. For backside illumination, the imager was thinned by etching away the substrate was etched away in a post-fabrication processing step.

Complementary Metal Oxide Semiconductor imager (CM↗

Reaching the Diffraction Limit - Differential Speckle and Wide-Field Imaging for the WIYN Telescope

Speckle imaging allows telescopes to achieve diffraction limited imaging performance. The technique requires cameras capable of reading out frames at a very fast rate, effectively 'freezing out' atmospheric seeing. The resulting speckles can be correlated and images reconstructed that are at the diffraction limit of the telescope. These new instruments are based on the successful performance and design of the Differential Speckle Survey Instrument (DSSI).The instruments are being built for the Gemini-N and WIYN telescopes and will be made available to the community via the peer review proposal process. We envision their primary use to be validation and characterization of exoplanet targets from the NASA, K2 and TESS missions and RV discovered exoplanets. Such targets will provide excellent follow-up candidates for both the WIYN and Gemini telescopes. We expect similar data quality in speckle imaging mode with the new instruments. Additionally, both cameras will have a wide-field mode and standard SDSS filters. They will be highly versatile instruments and it is that likely many other science programs will request time on the cameras. The limiting magnitude for speckle observations will remain around 13-14th at WIYN and 16-17th at Gemini, while wide-field, normal CCD imaging operation should be able to go to much fainter, providing usual CCD imaging and photometric capabilities. The instruments will also have high utility as scoring cameras for telescope engineering purposes, or other applications where high time resolution is needed. Instrument support will be provided, including a software pipeline that takes raw speckle data to fully reconstructed images.

detector↗

Development of Multi-Edge Slant Target for Unlocalized MTF Measurement of Airborne Imaging System Payloads

Calibration of imaging instruments is a critical step in effectively characterizing imaging data. A comprehensive characterization of an imaging system provides valuable insight into the overall uncertainties in the results derived from the raw data collected. The Scientifically Calibrated In-Flight Imagery (SCIFLI) team (based at NASA Langley Research Center) has designed, built, tested, and successfully flown the optical payload known as the SCIFLI Airborne Multispectral Imager (SAMI). SAMI is a multispectral imaging payload, complete with sensor configurations for the Ultraviolet-Visible spectrum as well as Near- Infrared, Shortwave Infrared, and Midwave Infrared bands and is fitted with various optical hardware designed to turn, split, and focus light beams to the respective in-band sensors. Radiometric calibrations are performed for SAMI such that the accuracy and uncertainty of thermal and spectral measurements are effectively characterized. However, SAMI does not regularly undergo spatial characterizations to evaluate the performance of the imager at high spatial frequencies. This is essential, as understanding the spatial sensor response of discrete sensors is just as important as the spectral sensor response. The payload currently utilizes a calibration cart for lab testing. Equipped with a modular setup and several radiation sources, it is perfect for performing high-quality radiometric calibrations. This work focuses on using the calibration cart to perform spatial calibrations. A custom designed calibration target is being used to evaluate the optical performance of SAMI. Specifically, the target is designed to measure the Modulation Transfer Function (MTF) of the imager in discrete locations around the focal plane. The results of this characterization will provide insight into the spatial resolution capabilities of the SAMI payload in practice. Future work includes using the results of the study to correct optical imperfections in imagery taken with SAMI.

SAMI↗

Phase-Sensitive Coherence and the Classical-Quantum Boundary in Ghost Imaging

The theory of partial coherence has a long and storied history in classical statistical optics. the vast majority of this work addresses fields that are statistically stationary in time, hence their complex envelopes only have phase-insensitive correlations. The quantum optics of squeezed-state generation, however, depends on nonlinear interactions producing baseband field operators with phase-insensitive and phase-sensitive correlations. Utilizing quantum light to enhance imaging has been a topic of considerable current interest, much of it involving biphotons, i.e., streams of entangled-photon pairs. Biphotons have been employed for quantum versions of optical coherence tomography, ghost imaging, holography, and lithography. However, their seemingly quantum features have been mimicked with classical-sate light, questioning wherein lies the classical-quantum boundary. We have shown, for the case of Gaussian-state light, that this boundary is intimately connected to the theory of phase-sensitive partial coherence. Here we present that theory, contrasting it with the familiar case of phase-insensitive partial coherence, and use it to elucidate the classical-quantum boundary of ghost imaging. We show, both theoretically and experimentally, that classical phase-sensitive light produces ghost imaging most closely mimicking those obtained in biphotons, and we derived the spatial resolution, image contrast, and signal-to-noise ratio of a standoff-sensing ghost imager, taking into account target-induced speckle.

coherence theory↗

Dual particle imaging using time-of-flight neutron classification

Fast-neutron imaging technology is well-suited for passive nuclear material monitoring, secondary inspection of flagged cargo, and wide-area search for lost neutron sources. However, imaging systems that use pulse shape discrimination for event classification require complex pulse waveform analysis. In this work, we evaluate time-of-flight (TOF) based particle classification as an alternative solution for fast-neutron imaging by classifying all events with a TOF above a maximum threshold as neutrons. We measured a Cf-252 source next to Cs-137 using a 12-bar organic-glass scintillator array. By varying the TOF thresholds for neutron identification, we demonstrate a clear trade-off between event yield and backprojection image fidelity, with stricter thresholds improving precision at the cost of statistics, TOF thresholded data generated an image that predicted the neutron source direction with 20% reduced mean central angle prediction error compared to a traditional pulse shape discrimination (PSD) method with comparable event count. Time-of-flight particle classification shows promise as an alternative to pulse shape discrimination systems for fast neutron imaging systems looking to minimize costs and size of electronics with comparable imaging quality. The sources used demonstrate that the method is effective in classifying measured neutrons in a measurement environment with 150 μCi Cs-137 and 1.6 × 10 6 n/s Cf-252 sources positioned at distances of 66 cm and 81 cm from the detector. Additionally, the method classifies low-energy neutron events that pulse shape discrimination removes, so a combination of both methods would result in a higher overall neutron event efficiency.

Heriot, William [Univ. of Michigan, Ann Arbor, MI ↗

Image processing pipeline for AI-driven nanoparticle megalibrary characterization

Recent innovations have made it possible to produce megalibraries, millions of structurally and compositionally distinct nanoparticles on a chip. These megalibraries yield vast volumes of data that are impossible to analyze manually, necessitating the development of automated tools. In previous work, we created a binary classification machine learning model to select quality nanoparticle images for downstream analysis. In this work, we show that adding a custom image processing step before training can produce significantly higher-performing models in a fraction of the time and make them more robust to different image noise levels and microscope acquisition settings. The image processing pipeline proposed here effectively cleans raw nanoparticle images, enhances key features, and allows us to use much lower resolution images and simpler neural network model architectures. These features result in higher performance and significant cost savings. Experiments demonstrate superior performance relative to baseline, including an 18.2% improvement in recall and a 13.1% increase in accuracy. Given the high cost of downstream analysis, it is critical to minimize false positives, and our best-performing model reaches a precision of 95.9% and a weighted F-score of 95.1% on an unseen test set. Additionally, model training time is reduced from hours to less than a minute. We also show that, using this custom image processing pipeline, model performance is significantly improved at lower pixel resolutions compared to downsizing alone. We expect that adopting this pipeline for AI-driven automated nanoparticle characterization will allow researchers to rapidly and accurately analyze much greater volumes of data, thereby accelerating materials discovery.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Dark-field X-ray microscopy with structured illumination for three-dimensional imaging

Dark-field X-ray microscopy is a lens-based technique that enables real-space imaging of heterogeneous micro- and meso-scale ordered materials. However, achieving accurate three-dimensional (3D) reconstruction often requires meticulous sample alignment or rastering, requiring complex rotational setups and extended acquisition times. To address these challenges, we introduce a structured illumination technique optimized for 3D imaging of ordered materials at sub-micrometer length scales. Our approach employs a coded aperture to spatially modulate the incident X-ray beam, enabling 3D structural reconstruction from images captured at various aperture positions. Unlike current 3D imaging approaches, which often rely on rotational or rastering methods, our technique uses scanning X-ray silhouettes of the coded aperture for depth resolution along the diffraction axis. This eliminates the need for sample rotation or rastering, resulting in a highly stable and efficient imaging modality. We validated the efficacy of this approach through experimental imaging of an isolated twin domain within a bulk single crystal of an iron pnictide using a dark-field X-ray microscope. This advancement aligns with the enhanced brightness upgrades of modern synchrotron radiation facilities, unlocking new possibilities for high-resolution imaging of ordered materials.

47 OTHER INSTRUMENTATION↗

Wide-field microwave magnetic field imaging with nitrogen-vacancy centers in diamond

Non-invasive imaging of microwave (MW) magnetic fields with microscale lateral resolution is pivotal for various applications, such as MW technologies and integrated circuit failure analysis. Diamond nitrogen-vacancy (NV) center magnetometry has emerged as an ideal tool, offering micrometer-scale resolution, millimeter-scale field of view, high sensitivity, and non-invasive imaging compatible with diverse samples. However, up until now, it has been predominantly used for imaging of static or low-frequency magnetic fields or, concerning MW field imaging, to directly characterize the same microwave device used to drive the NV spin transitions. In this work, we leverage an NV center ensemble in diamond for wide-field imaging of MW magnetic fields generated by a test device employing a differential measurement protocol. The microscope is equipped with a MW loop to induce Rabi oscillations between NV spin states, and the MW field from the device-under-test is measured through local deviations in the Rabi frequency. This differential protocol yields magnetic field maps of a 2.57 GHz MW field with a sensitivity of ∼9 μT Hz −1/2 for a total measurement duration of T=357 s, covering a 340 × 340 μm 2 field of view with a micrometer-scale spatial resolution and a device-under-test input power dynamic range of 30 dB. This work demonstrates a novel NV magnetometry protocol, based on differential Rabi frequency measurement, that extends NV wide-field imaging capabilities to imaging of weak MW magnetic fields that would be difficult to measure directly through standard NV Rabi magnetometry.

crystallographic defects↗

Mitigating imaging systematics for DESI 2024 emission Line Galaxies and beyond

Emission Line Galaxies (ELGs) are one of the main tracers that the Dark Energy Spectroscopic Instrument (DESI) uses to probe the universe. However, they are afflicted by strong spurious correlations between target density and observing conditions known as imaging systematics. In this paper, we present the imaging systematics mitigation applied to the DESI Data Release 1 (DR1) large-scale structure catalogs used in the DESI 2024 cosmological analyses. We also explore extensions of the fiducial treatment. This includes a combined approach, through forward image simulations (Obiwan) in conjunction with neural network-based regression, to obtain an angular selection function that mitigates the imaging systematics observed in the DESI DR1 ELGs target density. We further derive a line of sight selection function from the forward model that removes the strong redshift dependence between imaging systematics and low redshift ELGs. Combining both angular and redshift-dependent systematics, we construct a three-dimensional selection function and assess the impact of all selection functions on clustering statistics. We quantify differences between these extended treatments and the fiducial treatment in terms of the measured 2-point statistics. We find that the results are generally consistent with the fiducial treatment and conclude that the differences are far less than the imaging systematics uncertainty included in DESI 2024 full-shape measurements. We extend our investigation to the ELGs at 0.6 < z < 0.8, i.e., beyond the redshift range (0.8 < z < 1.6) adopted for the DESI clustering catalog, and demonstrate that determining the full three-dimensional selection function is necessary in this redshift range. Our tests showed that all changes are consistent with statistical noise for BAO analyses indicating they are robust to even severe imaging systematics. Specific tests for the full-shape analysis will be presented in a companion paper.

79 ASTRONOMY AND ASTROPHYSICS↗